MicroCommander
Engine Control
Installation Instructions
for 580 Actuator only
Manufactured by:
Mathers Controls Inc.
675 Pease Road
Burlington, WA 98233
1-800-546-5455
Fax: 1-360-757-2500 MMC-153 Rev. 5
e-mail: mathers@matherscontrols.com RPN: 00661
.
THIS PRODUCT IS INACTIVE!
Please contact Mathers Controls for support information.
Table of Contents
1. GENERAL INFORMATION ......................................................................... 1
Page i
6. TESTS .................................................................................................. 14
6.1 A DJUSTMENTS TO C HECK UNDERWAY ............................................................ 15
6.1.1 Full-Speed Setting ......................................................................... 15
6.1.2 Proportional Pause On Direction Change ............................................. 15
6.2 C ONTROL H EAD TONE .............................................................................. 16
7. CONTROL OPTIONS .............................................................................. 16
7.1 H IGH ('HI') I DLE .................................................................................. 16
7.1.1 'HI' Idle Setting ............................................................................. 17
7.2 P RIMARY S TATION I SOLATION S WITCH ........................................................... 17
7.3 A LARM C APABILITY ................................................................................. 18
7.4 G EAR OIL P RESSURE I NTERLOCK ................................................................. 18
8. OPERATOR INSTRUCTIONS ................................................................... 18
8.1 C ONTROL S YSTEM S TART - UP ...................................................................... 18
8.2 E NGINE S TART ...................................................................................... 19
8.3 S TATION TRANSFER ................................................................................ 19
9. MORSE CLUTCH AND THROTTLE KIT SELECTION ..................................... 19
9.1 P RE -E NGINEERED THROTTLE C ONNECTION KITS ................................................ 19
9.2 P RE -E NGINEERED C LUTCH C ONNECTION KITS ................................................... 20
9.3 O UTBOARD A ND I/O C ABLE C ONNECTION KITS ................................................. 20
10. UNIVERSAL MOUNTING FOR 33C TYPE CABLE ....................................... 21
Page ii
16.4 SYMPTOM: H IGH R ATE TONE AT C ONTROL H EAD WHEN SHIFTING OR MOVING UP IN THE
SPEED RANGE . ........................................................................................... 29
16.5 SYMPTOM: S TEADY TONE AT C ONTROL H EAD . .............................................. 29
16.6 SYMPTOM: O NE L ONG - O NE S HORT TONE AT THE C ONTROL H EAD . ..................... 29
16.7 SYMPTOM: O NE L ONG - T WO S HORT TONES AT THE C ONTROL H EAD . ................... 29
17. WARRANTY AND REGISTRATION.......................................................... 30
Page iii
Page iv
1. GENERAL INFORMATION
The MicroCommander engine control system provides single lever operation of
throttle and shift from one to five remote stations. The control system operates
from a 12 volt DC power source and in the static condition draws only 0.4
amperes. The MicroCommander will operate outboards, I/O's and inboards, either
gas or diesel powered.
The control system is sequenced such that the throttle must be at 'IDLE' in order
to shift and shift must then be completed before the throttle will advance.
The connection to the engine throttle and clutch is through standard Morse Type
33C push-pull cable. (Ref. 3, J917, Sect. 11)
Requirements:
• Throttle or clutch selector lever load should not exceed 40 lbs.
• MicroCommander requires a battery supply of 12 to 16 volts DC and could
draw a maximum of 10 amperes.
• The 12 volt DC power required is to be supplied through a 10 ampere, push
button type, circuit breaker. (One for each Actuator)
CAUTION: Avoid using the starting battery if possible. A dedicated battery for
MicroCommander and other electronic equipment is recommended. Do
not use a power converter or battery charger without a battery.
Page 1
2.1.3 Electric Cable
Pc.No. 180
Eight-Conductor Cable (Control Head to Actuator) Pc.No. 350
500 foot (152m) spool
Shielded 20 AWG, 300 V, PVC Insulated: -20/C to +80/C, PVC Jacket.
Color Coded UL VW-1.
Pc.No. 212
Two-Conductor Cable 12 V Supply, 250 foot (76m) spool Pc.No. 349
14 AWG, 300 V, PVC Insulated: -20/C to +105/C PVC Jacket.
Red with purple stripe and black UL VW-1.
Pc.No. 183
Two-Conductor Cable Start Interlock, 250 foot (76m) spool Pc.No. 355
16 AWG, 300 V, PVC Insulated: -20/C to +105/C PVC Jacket.
Yellow with red stripe UL VW-1.
2.2 SUPPLIED BY INSTALLER
2.2.1 Tools Required For Installation
Anti-static wrist strap is included with Actuator.
Wire cutter (Recommend Thomas & Betts WT-2000)
Wire stripper (Recommend Thomas & Betts WT-2000)
Wire crimper (Recommend Thomas & Betts WT-2000)
7/16" Socket and medium extension
3/8" Wrench
7/16" Wrench
Screwdriver - medium phillips head #2
Screwdriver - medium straight slot
Screwdriver - small straight slot
Hole saw - 1" (25,4mm)
Drills - 9/32" (7,2mm) and 7/32" (5,6mm)
2.2.2 Push-Pull Cables
Type 33C push-pull cables. (Two per engine) The cable length is measured
from end of thread to end of thread. Cables are usually stocked in one foot
(0,3m) increments.
Page 3
• When mounting a Control Head that may be weather exposed from the
underside, consider using a Weather Mounting Control Box, Pc.No. 722 (See
Dwg. 0310-A).
• Retrofit applications will need to plan an adapter pad to cover the old
Control Head cutout and to mount the Control Head. Adapter and cover pad
available from Mathers Controls Inc.
3.3 12 VOLT DC POWER
The MicroCommander Actuator requires a 12 volt DC battery source protected by
a 10-ampere circuit breaker. It is not recommended to use engine starting
batteries on 12 volt systems, because the cranking voltage may be too low. It
is important to keep the length of power cable short to reduce voltage drop.
The 14 gauge twisted pair power cable, should not exceed 20 feet (6m) . If
individual wires are used for supply (+) and return ( - ) then the total wire
length should not exceed 40 feet (12m) .
Figure 1
Power Source
NOTE: It is important that the wire size from the battery to the circuit breaker panel
is large enough to keep voltage drop due to current flow, to less than 3%.
The DC return to the battery must be large enough to supply all current
requirements with a voltage drop of less than 1 volt. (See References,
Sect. 11)
4. INSTALLATION
Before starting the actual installation of the MicroCommander Engine Control
make sure you have the correct parts and tools on hand. See Section 2
REQUIRED PARTS AND TOOLS. Read all the instructions pertinent to each part
before beginning the installation of that part.
Page 4
WARNING: Static electricity can destroy electronic
components. Anytime the Actuator cover
is off, use the wrist strap provided and
connect it to the Actuator frame. This
will drain any static charge you may
have on your person.
Figure 3
Recessed Mount Surface Mount
Page 5
4.4 ENGINE 'START' SWITCH Start Interlock
Key Connections
MicroCommander is interlocked to prevent 'START' Start Maximum 30 Amperes
until control system power is 'ON' and the reverse Interlock
gear is in Neutral. The engine 'START' signal must
be connected through the Actuator to the starter
Starter
solenoid or relay. (See Figure 4) The interlock Solenoid Actuator
will function with a 'START' signal up to 50 volts
DC and 30 ampere maximum.
CAUTION: The circuit board is designed for a
maximum of 30 amperes 'START' signal
current. Greater current will damage the
Starter
interlock circuit.
Page 6
To Station
Transfer Button
Socket
Connector
on
Orange
White
Orange
Control
Head Black
Brown
Depress Red
Sprint Lock White
Yellow
with small Green
Blue
screwdriver
Tie Wrap
Insert wire Violet 3/8"
against Stop
Connector - Plug 8-Conductor Cable Connector
into Socket 0643A
Figure 5
Control Head Socket Connection
NOTE: Starboard Control Head lever connection shown. (Reverse blue and yellow for
Port Control Head lever).
Twin Screw Synchronization
Dual Control Head Dual Control Head
without Synch with Synch
Indicator Light Port Indicator Light Starboard
Starboard (Lead) (Follow)
Port (Red LED) (Red & Green LED)
Station Station
Transfer Transfer
Button Button
12345678 12345678 12345678 12345678
Orange Orange
Orange Orange
White White
Orange
Orange
Orange
Orange
Yellow
Yellow
Brown
Brown
Yellow
Yellow
Brown
Brown
Green
Green
Green
Green
Violet
Black
Black
Black
Black
Blue
Blue
Blue
Blue
Red
Red
Red
Red
0651A 0651A-Sync
Figure 6 Figure 7
Terminal Connection Sync. Terminal Connection
CAUTION: When making a twin screw installation, the white wire connects to
Terminal 3 on the Port Control Head only. The Starboard Terminal 3 is
not connected. This is true at all stations. See Circuit Dwg., Section
13. Cable must be supported to eliminate load on Terminal
Connections.
Page 7
Power
Station 1
Hole Station 3
Plug
Station 5
Screwdriver Start
Interlock
Actuator
Actuator Station 2
Electric Station 4
0653A
Cable
Auxiliary
Push Seal
Cable 0652A
Grip
Figure 8 Figure 9
Plug Removal Cable to Actuator
-
+ PCE
1
Fuse
1
JMPR2
1 Black 1
JMPR2
8
Station 2
Station 1
2 7
2 Brown
3 6
4 5
5 4
3 Red 6
7
3
2
4 Orange
8 1
Power
5 Yellow
1
8
Station 3
2
Station 4
7
3
6 Green
6
Shunt
4 5
5
JMPR1 4
7 Blue
6 3
7
8
Station 5 2
8 Bare
1 2 3 4 5 6 7 8 1
JMPR1
Power Start
Cable Grip Interlock
Tie Wrap Cable Grip
Ferrite
Bead 10889
Figure 10
Actuator Connections
Page 8
4.8 BONDING A.B.Y.C. E-1 46 CFR 111.05
All boats equipped with a
permanently installed electrical Actuator
system shall be equipped with a
bonding system. The negative
terminal of all batteries should be
connected at only one point, the DC
common and from DC common to
bond system or hull.
Metal - Hull Vessels
The hull of a metal - hull vessel may
serve as the common bonding
conductor. Any item to be bonded
not in contact with the hull requires a
bonding conductor to the hull.
4.9 ACTUATOR
Remove the Actuator cover and
connect your anti-static wrist strap
to the Actuator frame and your wrist.
Remove the cable hole plugs as
required. (See Figure 8) Install the
watertight cable grip that is included Figure 11
with the Control Head. Station No. 1 Bonding
will connect to 'STATION 1' as
indicated in Figure 9. Strip the PVC
cover and shielding back
approximately 2" (50,8mm) . The wire
leads can be staggered for length to
match the Station 1 terminal strip.
Strip the wire 3/8" (9.5mm) on each
lead. It is also recommended that
the wire be LIGHTLY tinned. Rotate
Connect colors as indicated in Figure
WAGO
10. A WAGO Tool, No. 236-332, is
Tool
included with each Actuator. It is
Terminal Strip
taped to the relay on the circuit
board. It is used to depress the
spring lock for the individual wire
connection to the terminal strip. One Wire of
(See Figure 12) The shielding drain Eight-Conductor
wire (bare wire) must be connected Insert Tool and Rotate
to terminal 8 on the terminal strip. 0656 Forward to Release Spring
Lock and Insert Wire End.
Feed through a little slack cable Circuit Board
and tighten the cable grip on the
Figure 12
Eight-Conductor cable. The other
stations Eight-Conductor cables are Terminal Connection
brought in the same way and are
Page 9
connected to the appropriate terminal. (See Figure 9) Secure the cable to the
frame using tie wraps provided.
4.10 CONNECT 12 VOLT DC POWER TO ACTUATOR
When connecting the DC power cable to the Actuator be sure the power is 'OFF'.
The (+) positive lead (red with purple stripe) connects the + DC power source
to the Actuator. (See Figure 1) The (-) negative lead is black. The ferrite bead
is fed onto the power cable before entering the Actuator. Tie wrap the power
cable to the frame and tighten the cable grip.
4.11 INSTALL START INTERLOCK CABLE
NOTE: Maximum current rating of interlock relay is 30 amperes.
The start interlock cable, two wires are yellow with a red stripe. Remove the
key start lead at the start solenoid. (See Figure 4) Connect one yellow with red
striped wire to this lead and the other yellow with red striped wire to the start
solenoid. Run the cable to the Actuator through the cable grip to the start
interlock connections on the Actuator circuit board. See circuit drawings in Sect
12 and 13. The Actuator provides a start interlock that requires the control
system to be 'ON' and clutch in Neutral. The 'START' signal voltage can be 12,
24 or 32 volts as it only passes through a relay in the Actuator.
NOTE: The most common source of trouble is loose wiring connections. Make certain
that wiring connectors are properly crimped and cannot be pulled out. Crimps
and connections must be made to the wire, NOT to the wire insulation. All
screwed wire connections must be checked to see they are secure.
5. ADJUSTMENTS
A) Turn the power 'ON' to the control system.
B) The Control Head at each remote station will produce an intermittent tone.
C) Depress one station transfer button (Control Head lever in Neutral). The red
indicator light on the Control Head should be lit, showing this remote station
has command. Note on dual Control Head, both red indicator lights must be
lit.
D) Move the Control Head lever Full-Ahead and Full-Astern. This will check that
the Control Heads are operating.
WARNING: Keep hands and tools clear of the Actuator when power is 'ON'. Turn
'OFF' the control system power before disconnecting the 12 volt
batteries. Do not disconnect battery terminals when engine is
operating.
Page 10
5.1 ACTUATOR
Actuator Settings (as shipped)
Throttle R7 Pot Fully counterclockwise gives minimum throttle.
'HI' Idle R8 Pot Fully counterclockwise . Leave in this position
unless the 'HI' Idle option is selected. (See
Section 7.1)
JMPR 1 Shunt between 2 and 3 set for Station 5.
JMPR 2 Shunt open as set for Station 5.
SW1 Settings (as shipped)
Clutch (1) 'OFF' Clutch cable 'PULL' Ahead.
Direction
Clutch (2) 'ON' 1/4" (6.4mm) All switches 'ON' gives minimum cable travel.
Movement (3) 'ON' 1/8" (3.2mm) Switches to 'OFF' gives incremental increase.
(4) 'ON' 1/16" (1.6mm) Dimensions are each side of center.
Pause Clutch (5) 'OFF' Provides a maximum pause from Full-Ahead of 3.25
engaged Ahead seconds.
(6) 'ON'
Section 6.1.2, lists optional settings.
(7) 'OFF'
Throttle Pause (8) 'OFF' Throttle pause of 0.5 second following shift. Use when
controlling hydraulic actuated clutches.
Throttle (9) 'OFF' Throttle cable PUSH to increase speed.
Direction
5.2 CHECK CONTROL HEADS AND STATION TRANSFER
'ON' 1 2 3 4 5 6 7 8 9
Push Down
for 'ON' NOTE:
To Change, use a small
screwdriver.
Push Down
for 'OFF'
'OFF' 0657-580
Figure 13
SW1 Dip Switch
Move to each remote station, and with the Control Head levers in the Neutral
position, PUSH in the station transfer button. The indicator light on the Control
Head will confirm that command transfer has taken place and that you have
command.
The Control Heads are direction sensitive. To prove that the Control Head
wiring connections are correct:
A) Place the Control Head levers in the Neutral position.
Page 11
B) Depress and hold the station transfer button and then move the Control Head
lever to the Ahead detent position.
C) The red indicator light on the Control Head should blink. The blinking
indicator light shows that the clutch is in Neutral and the Control Head lever
will position the throttle only.
D) If the red indicator light is 'ON' in Ahead and blinks in Astern, then
connections 5 and 7 on the Control Head connector must be reversed (See
Sect. 4.7).
E) The 'WARM-UP' Mode must operate only in the Ahead direction.
F) There are no further adjustments to the Control Head.
5.3 PUSH-PULL CABLES
WARNING: Misadjusted clutch and throttle cables cause motors to burn out. Do it
right by following these instructions:
A) Check that push-pull cable anchor brackets are installed on the engine. If
the brackets are not on the engine, select from Sect. 9, or fabricate brackets
as shown in Sect. 10.
B) As shipped from the factory, Actuator switch (SW1) 1 is 'OFF', and therefore,
the push-pull cable will 'PULL' on the clutch selector lever for Ahead. If this
is correct, leave it. If it is wrong, change switch 1 to 'ON' and the push-pull
cable will PUSH the clutch selector lever for Ahead.
C) As shipped from the factory, Actuator switch (SW1) 9 is 'OFF', and therefore,
the push-pull cable will PUSH the throttle lever for Full-speed. If this is
correct leave it. If it is wrong, change switch 9 to 'ON' and the push-pull
cable will 'PULL' on the throttle lever for Full-speed.
D) Connect the push-pull cables to the MicroCommander Actuator (See Figure
14). Remove the #10-32 jam nut and the two rubber seals from the push-
pull cable end that is to connect to the Actuator. Reinstall the #10-32 jam
nut. Remove one cable anchor clip screw from the Actuator housing and
swing the cable clips clear. Connect the shift cable and throttle cable to the
proper hex nut. See label on the Actuator. (See Figure 14, Detail I) Use a
Actuator Housing
See Detail I
7/16"
(8mm)
7/16"
Socket
SHIFT THROTTLE
Detail I
Push-Pull Cable Anchor Clip Push-Pull Cable 1/4" Mounting Hardware
0658A
Front View Side View
Figure 14
Push-Pull Cable Connection
Page 12
7/16" socket to turn the hex nut onto the #10-32 cable rod end until there is
5/16" (7,9mm) of thread showing beyond the jam nut. Tighten the #10-32
jam nut to the hex nut. Install the cable anchor clips to secure the Type 33C
cable to the Actuator housing.
5.3.1 Reverse Gear Cable Adjustment
A) Place the Control Head levers in Neutral and turn the control system 'ON'.
B) Adjust the clutch cable ball joint at the engine to match the clutch selector
lever in Neutral. The push-pull cable should form a right angle (90
degrees) to the shift selector lever in the Neutral position. Leave the cable
disconnected.
C) Move the Control Head lever to the Ahead detent. The Actuator can be
adjusted for a total clutch movement of 2" (51mm) to 3" (76mm) . The
Actuators are shipped with switches set for minimum movement.
D) Measure the clutch selector lever movement from Ahead to Astern detent.
The selector lever movement must be within the adjustment range of 2"
(51mm) to 3" (76mm) .
SW1 will increase the clutch movement in each direction from Neutral by
moving the switches from 'ON' to 'OFF'.
Switch 2 1/4" (6,4mm)
Switch 3 1/8" (3,2mm) APPROXIMATE DIMENSIONS
Switch 4 1/16" (1,6mm)
E) Match the required movement and then check the Astern direction.
Recheck Ahead, Neutral, and Astern with the clutch cable disconnected.
Confirm that the Actuator does not jam the clutch selector lever against its
stops and that Neutral is correct. Connect the clutch cable.
5.3.2 Throttle Cable Adjustment
A) Check that potentiometers R7 and R8 are in the fully counterclockwise
position, as shipped from the factory.
CAUTION: Potentiometers can be damaged by turning too hard against the stop.
B) Measure the throttle movement at the engine from 'IDLE' to 'FULL'. It must
be within the Actuator range of 1" (25,4mm) to 2-7/8" (73mm) . If the throttle
movement is less than 1" (25,4mm) or greater than 2-7/8" (73mm) the lever
radius must be changed to be within range. If possible, throttle movement
should be 2-1/2" (64mm) 'IDLE' to 'FULL'. Leave throttle cable disconnected
at this time.
C) Place Control Head levers in Neutral, 'Start' engine and run at 'IDLE'.
Adjust ball joint on throttle cable to match throttle lever 'IDLE' position.
D) Stop the engine. Move the Control Head lever to Full-speed. Move throttle
lever to the Full-speed stop. Gradually turn potentiometer R7 on the
circuit board clockwise until the ball joint can be connected with a slight
amount of pressure against the Full-speed throttle stop. Recheck 'IDLE'
and 'FULL'. Connect ball joint to throttle lever. The throttle adjustment is
complete.
Page 13
5.4 STATION TRANSFER
The operator can leave the Station-in-Command with the Control Head lever in
any position from Full-Ahead to Full-Astern. To gain command at any other
remote station the Control Head lever must be in the Neutral position. When
the Control Head indicator light shows red, the operator has command. There is
a one second pause after the indicator light is 'ON' to allow the operator time to
match the previous speed setting before command transfer takes place.
5.5 START INTERLOCK
A) Check proper operation of start interlock:
B) Turn 'OFF' 12 Volt DC power to MicroCommander, check that engines will not
'START'. Control system off interlock check.
C) Turn 'ON' 12 Volt DC power to MicroCommander, accept command, place
Control Head lever to Ahead detent and check that engines will not 'START'.
Clutch in Neutral, interlock check.
D) Place Control Head lever in Neutral, engines should 'START' in this position.
5.6 THROTTLE PAUSE
Hydraulic actuated clutches require 0.5 second or longer following selector lever
movement before there is clutch plate contact. SW1 switch 8 in the 'OFF'
position allows 0.5 second Idle throttle pause after clutch selector movement is
complete. Dog clutches and cone clutches used on some I/O's and outboards do
not require a throttle pause following clutch shift and switch 8 should be 'ON'.
Some clutches may build clutch pressure slowly. This could mean high engine
RPM before clutch engagement. A gear oil pressure interlock is available and is
described in Sect. 7.4.
5.7 FINAL CHECK
A) Shut 'OFF' the engine.
B) Check that all push-pull cable connecting fasteners are tightened securely.
C) Operate Control Head levers Ahead and Astern and check clutch selector
lever movement. Operate Control Head levers from Idle to Full-Ahead and
check throttle movement.
D) Check that the push-pull cable jam nut in the Actuator is tight. (See Figure
12, Detail I) If this is not done the Hex Nut can back off the push-pull cable
threaded end and effectively change the cable length. Shift and throttle
cables must have jam nuts tightened.
6. TESTS
Do the following tests with the vessel secured to the dock:
A) 'START' engine and check that engine 'STOP' switches (normally a push
button) function correctly at all remote stations.
B) Idle the engines and place one Control Head lever at a time in the Ahead
detent and then the Astern detent. Do this at each remote station to confirm
direction command.
Page 14
C) Then use 'WARM-UP' Idle on each engine at each remote station, one engine at
a time to confirm speed command.
D) Check that all the above tests are made and are correct. Only then is the
vessel ready to leave the dock.
WARNING: Do not attempt to operate the control system away from the dock with
any system abnormality.
NOTE: The pause in gear on a through shift is proportional to the amount of the
speed commanded and time at that speed. The times listed above are
maximum. Shifting from Idle 'AHEAD' to Idle 'ASTERN' the pause is ZERO.
The time required to build to the maximum pause is six times the pause listed
above. The pause from Full-Astern to Ahead is half that listed above for Full-
Ahead to Astern.
Page 15
6.2 CONTROL HEAD TONE
There are five functions of the tone.
• Low Repetition Tone is normal when DC power is first applied to the
control system. This tone shows the control system is in Neutral and Idle
and the operator can take command by depressing a station transfer button.
If the operator places the Control Head lever to the slow Ahead position
before depressing the transfer button, they will get warm-up speed command
with a blinking red light. The clutch will remain in Neutral.
• High Repetition Rate Tone is used to signal a jam condition of either the
shift or throttle cable. The Actuator has stopped when this tone is heard.
Moving the Control Head lever away from the position the tone was
encountered will usually stop the signal. The cause of the high push-pull
cable load must be found. Disconnect the throttle and shift cables at the
engine and check the engine and gear levers for heavy loads. Operate the
control system by moving the push-pull cables only, to confirm the cables
are moving freely. Check to see that the push-pull set up is adjusted
correctly. (See Sect. 5.3)
• Steady Tone is used to signal a voltage problem or a component has failed.
Confirm the voltage is steady between 12 and 16 volts DC and that there is
not a momentary voltage drop. Depress the station transfer button. If the
tone continues the Actuator or circuit board may need to be replaced.
• Repetitive Signal - One Long, One Short Tone is used to show a clutch
feedback error. See Sect. 16.6.
• Repetitive Signal - One Long, Two Short Tone is used to show a throttle
feedback error. See Sect. 16.7.
7. CONTROL OPTIONS
7.1 HIGH ('HI') IDLE
The MicroCommander offers an option of two Idle RPM settings for the engine.
The normal LOW ('LO') Idle RPM is set mechanically by adjusting the push-pull
cable ball joint at the engine to hold a little pressure against the engine Idle
stop. (As described in Sect. 5.3.2) A second 'HI' Idle RPM can be set
electrically. Pushing the station transfer button will alternately move the engine
Idle setting back and forth between 'LO' Idle and 'HI' Idle.
The 580 Actuator is shipped from the factory with five remote stations available.
When the 'HI' Idle option is selected, you eliminate Station 5. To obtain the
'HI' Idle option requires the following adjustments to the circuit board (See
Figure 10).
• Move JMPR 1 shunt to pins 1 and 2.
• Close JMPR 2 shunt, both pins.
The result is that stations 1 through 4 are capable of 'HI' Idle and station 5 is
inoperative.
Page 16
7.1.1 'HI' Idle Setting
'HI' Idle is set using potentiometer R8. When turned fully counterclockwise
'HI' Idle is minimum and is the same as 'LO' Idle. R8 is shipped this way from
the factory.
To adjust 'HI' Idle, place the Control Head levers in Neutral and 'START' the
engine. Depress and hold the station transfer button at the remote station in
command and move the Control Head lever to the Ahead detent position. The
blinking light at the Control Head shows 'WARM-UP' Mode. THE
MICROCOMMANDER IS ALWAYS IN 'HI' IDLE MODE WHEN THE INDICATOR
LIGHT IS BLINKING. Adjust 'HI' Idle using potentiometer R8, ONLY when in
'WARM-UP' Mode with the indicator light blinking and the Control Head lever in
the Ahead detent position (Idle position).
Rotate potentiometer R8 clockwise to the desired 'HI' Idle RPM.
Check your 'HI' Idle and 'LO' Idle settings by placing the Control Head lever in
Neutral and PUSH the station transfer button. Alternately the RPM will move
back and forth between 'LO' Idle and 'HI' Idle when the transfer button is
pushed. Twin screw, if 'HI' and 'LO' Idle are out of sync, place both engines in
Ahead Warm-up Mode. Both engines will then be 'HI' Idle.
CAUTION: Adjust potentiometer R8 for 'HI' Idle, only with the Control Head lever
in the Ahead detent and the indicator light blinking. Otherwise you
may be trying to adjust 'HI' Idle when you are in 'LO' Idle Mode.
Orange White
White White
White
Orange
Violet Violet
8-Conductor 8-Conductor
Actuator Port Actuator
Cable Cable
Starboard Actuator
- 1 - 1
+ 2
+ 2
1 1 1
8 8 8
Violet
Violet
Violet
7 7 7
Violet
6
5
4
Isolation 6
5
4
Isolation 6
5
4
Isolation
3 3 3
2 2 2
1 1 1
8-Conductor 8-Conductor
Cable Cable
0659A-580 0660A-580
8. OPERATOR INSTRUCTIONS
8.1 CONTROL SYSTEM START-UP Neutral
When the control system is turned 'ON', the MicroCommander
System will automatically move to Neutral and Idle position. Transfer
An intermittent 'TONE' will sound at all remote stations as Button
no station has command. The operator must depress the
station transfer button to get command. The tone will stop
at all stations and the indicator light will be 'ON' at the 715-1
Control Head
Station-in-Command. Only one station has command at a
time.
Page 18
8.2 ENGINE START
There are three features related to main engine 'START'.
Move to Speed Range
• The MicroCommander is interlocked to block the engine
'START' signal if the control system has not been
turned 'ON'.
Push &
• The MicroCommander is interlocked to block the engine
Hold
'START' signal if the clutch selector lever is in the
engaged position.
• The MicroCommander allows engine speed adjustment 715-2 Control Head
without engaging the clutch to help starting and
warming up a cold engine. This is called 'WARM-UP' Mode.
With the Control Head levers are in the Neutral position, depress and hold
down the station transfer button, move the Control Head levers to the Ahead
detent position. Now release the station transfer button. The indicator light
will blink, showing the clutch has stayed in Neutral. The operator can now
move the Control Head lever through the speed range and 'START' and warm-
up the engine. To reset the normal control system function, the operator
returns the Control Head levers to Neutral.
8.3 STATION TRANSFER
Only one remote station has command at a time.
Command is transferred by a transfer push button.
There is one push button at each remote station. When
transferring remote stations, the Control Head lever of
the Station-in-Command may be in any position. The
station taking command must be in the Neutral position.
The light on the Control Head is red when the remote
station has command. The indicator light at all other
stations will be 'OFF'. Command remains unchanged for
one second after the red light to allow the operator time 0662A
Receiving Station
to move the Control Head lever from Neutral to a in Neutral
position approximately matching the last speed setting.
Page 20
10. UNIVERSAL MOUNTING FOR 33C TYPE CABLE
Fabricate Bracket to match
dimensions shown
3/16" (4,8mm) Diameter
7-3/8" 1/4"
(6,4mm)
33C (187mm)
Cable Diameter
TYP
7/32" 90
(5,8mm) Shim
Diameter Cable Clamp 31638 Selector
31509 Lever
Jam Nut
Ball Joint
1" 31126 2-3/4"
(25,4mm) 1/4"-28 UNF (70mm)
Stud Maximum
Movement
10246A
11. REFERENCES
11.1.1 American Boat and Yacht Council (ABYC)
P.O. Box 806
Amityville, NY 11701
E-1 Bonding of Direct Current Systems
E-3 Wiring Identification on Boats
E-9 DC Electrical Systems on Boats
H-2.4e or 32.4g Ambient Temp. 50EC
11.1.2 Code of Federal Regulations
33 CFR 183 Subpart I - Electrical Systems
183, 410 Ignition protection
183, 415 Grounding
183, 425 Conductors: General
183, 430 Conductors in circuit of less than 50 Volts
183, 445 Conductors: Protection
183, 455 Overcurrent and Protection:
General
46 CFR 111.01 - 15(b) Ambient Temp.
Machinery Spaces 50EC
111.05 - System Grounds
11.1.3 Society of Automotive Engineers
400 Commonwealth Drive
Warrendale, PA 15096
J917 Marine Push-Pull Cables
J1171 External Ignition Protection
J1428 Marine Circuit Breakers
J378 Marine Engine Wiring
Page 21
11.1.4 National Marine Manufacturers Association
401 North Michigan Avenue
Chicago, IL 60611
11.1.5 Underwriters Laboratories
11.2 PARTS SOURCE
ANTI-STATIC WRIST STRAP, Thomas & Betts (Pc.No. AWCC) Pc.No. 517
CIRCUIT BREAKER, E-T-A Manufacturer (Pc.No. 41-2-514-LN2-10) Pc.No. 810
UL Approved
FUSE, Bussman (Pc.No. PCE - :) Pc.No. 840
WAGO TOOL, WAGO (Pc.No. 236-332) Pc.No. 397
RELAY 12 VDC, Potter-Brumfield (Pc.No. KRPA5D6-12) Pc.No. 1114
Page 22
12. SINGLE SCREW CIRCUIT
Station No. 1 Typical of Station 2 thru 5
on t n
t ar to
ut St rs) op op ut
n B e 4 St rs) St rs) n B
t i o fer 4 .
3 in the 4 . e 5 n e .5
e io er 4.
3
a s n g o n e
in th 4. gi oth n 4 at sf n
S t ran t i o En by t i o ng y o ion n St ran tio
T e c ( c E E by tio T ec
S Se (b ect ( ec S
S S
12345678 1 2 3 4 5 6 7 8
Orange Orange
Start
Run
+
White White
Orange
Orange
Yellow
Brown
Green
Yellow
Brown
Green
Black
Black
Blue
Blue
Red
Red
Shield Drain Wire and Foil
should be cut OFF flush
with end of Jacket.
Section 4.7
Violet Violet
SW1
1 Clutch
Black - 1 Power
2
Start 3 Clutch
Red + 2 Section 4.9 Interlock 4 Movement
1
PCE 1
5
Drain 8 Fuse 1 Black
6 Pause
Blue 7 STATION 2 2 Brown 7 In Ahead
Green 6 STATION 1 3 Red
8 Throttle Pause
Yellow 5 Power 4 Orange
Orange
Red
4 ON OFF 5 Yellow 9 Throttle
3 9 6 Green
Brown 2 JMPR2 7 Blue
Black 1 8 Drain
Violet Violet
8 1 1
7 JMPR1 2
6 STATION 3 SW1 3
5 4
4
3 STATION 4
5
6 R7 - Throttle
2 STATION 5 7 Travel
1 R7 R8 8
R8 - 'HI' Idle
JMPR1 - Station 5
or
8 Conductor 'HI' Idle
w/Shield JMPR2 - Station 5
Section 2.1 Bond or
'HI' Idle
ACTUATOR (see Section 5)
580
Red
Solenoid
Black Section 4.4
DC Power
See Section 3.3 Source
Starter
- +
Starting
DC Common Battery
Bond
See Section 4.8 ENGINE STARTING SYSTEM 0297G
Page 23
.
Station No. 1 Typical of Station 2 thru 5
Dual Control Dual Control
t Port n Stbd t Port n Stbd
ar o ar to op
op tt
u op
S t rs) S t rs) op B ut St rs)
S t rs)
5 e e .4 n r B .3 4 S t rs)
S t s) n 3 5
ne e . i n th 4 i n e t h e 4. i n e h e 4.5
g o n e er . 5 io e r 4. i ne the 4.
g o n
a tio s f e n 4 g ot n n h at s f n
n g i oth n 4 E n g y o i o n
E by t i o t St r a n tio E n b y tio E n y tio g i ot n 4 St r a n tio En by tio
( ec ( b ec T ec ( ec ( b ec E n by t i o T e c ( ec
S S S S S ( ec S S
S
12345678 12345678 12345678 12345678
Orange Orange Orange Orange
+
Run
Run
White
Start
Start
White
Black
Brown
Red
Orange
Yellow
Green
Blue
Shield Drain Wire and Foil
Black
Brown
Red
Orange
Yellow
Green
Blue
Black
Brown
Red
Orange
Blue
Green
Yellow
Black
Brown
Red
Orange
Blue
Green
Yellow
should be cut OFF flush
Violet Violet with end of Jacket. Violet Violet
Section 4.7
SW1
1 Clutch
Black - Black - 2
1 Power Start 1 Power Start
Red + Red + 3 Clutch
2 Section 4.9 Interlock 2 Section 4.9 Interlock
PCE 1
PCE 4 Movement
1 1 1
Drain 8 Fuse Black Drain 8 Fuse STATION 2 1 Black 5
STATION 2 1
13. TWIN SCREW CIRCUIT
Page 24
Section 2.1 3 STATION 4 6 3 6 JMPR2 - Station 5
2 STATION 5 7 2 STATION 5 7
1 R7 R8 8 1 R7 R8 8 or
87654321 87654321
'HI' Idle
(see Section 5)
PORT ACTUATOR STBD ACTUATOR
8 Conductor Bond Bond
w/Shield 580 580
Section 2.1
TRANSFER BUTTON
Two 7/32-inch (5,6mm)
Diameter Holes
R.50
(TYP)
3.75
(95,3mm)
CONTROL HEAD
Page 26
Page 27
15. MAINTENANCE
15.1 ACTUATOR
The Actuator does not require scheduled maintenance. If the Actuator becomes
noisy, a light coating of silicone grease may be applied to the lead screws.
15.2 CONTROL HEAD
The Control Heads should be checked at least once a year to insure the plug
connections are secure and free of corrosion. The plug contacts should be
checked and a light coating of Teflon grease or corrosion block applied.
Page 28
NOTE: As "come home" to bypass a bad start interlock relay in the Actuator, the
start interlock leads can be connected. Now the engine can be started
without the control system being turned 'ON' The problem must be corrected
as soon as possible.
Page 29
17. WARRANTY AND REGISTRATION
MICROCOMMANDER
LIMITED WARRANTY
Mathers Controls Inc. warrants this product to be free from defects in
material, assembly, and tests, for one year from the date of purchase.
Any unit that fails during the warranty period will, at Mathers Controls' option,
be repaired or replaced at no charge to the customer provided it is returned to
Mathers Controls freight prepaid with proof of date of purchase and a
description of the malfunction. Mathers Controls is not responsible for any
charges related to removal or installation of the product. Repair or replacement
during the warranty period will not extend the basic warranty period.
This warranty does not apply to a MicroCommander product that has failed due
to improper installation, misuse, or accident, nor does it apply to products
repaired or altered outside the Mathers Controls factory unless authorized in
writing by Mathers Controls Inc.
This warranty does not include incidental or consequential damages and
Mathers Controls disclaims any liability for any such damages. All implied
warranties, if any, are limited in duration to the above stated one year warranty
period. Some states and provinces do not allow the exclusion or limitation of
incidental or consequential damages, therefore, the above limitations may not
apply to you. The completion and return of the enclosed registration card
is a condition precedent to the warranty coverage. This warranty gives you
specific legal rights that may vary from country to country, state to state, and
province to province.
This warranty is limited only to the original purchaser of the unit.
Mathers Controls asks that the MicroCommander Installation Approval label
on the 580 Actuator be completed by a Factory Authorized Dealer. If the control
systems are owner or shipyard installed, a Factory Authorized Dealer should
check and approve the installation.
Page 30
Page 31
MICROCOMMANDER
WARRANTY REGISTRATION
Purchase Date
Dealer's Name
Installer's Name
Phone Number ( )
Purchaser's Name
Street Address
Phone Number ( )
YOUR VESSEL:
Length
Manufacturer
Page 33
Mathers Controls Inc.
675 Pease Road
Burlington, WA 98233-3101
Fold here
Page 34