Curve Pompa
Curve Pompa
Curve Pompa
self-priming
TECHNICAL DATA
APPLICATION CONSTRUCTION
The self-priming volute casing pumps according to DIN 24255 of Casing pressure:
the series ULN are applied when it is necessary to suck in and to
handle without problems and automatically, pure resp. turbid not Max. 10 bar from -40 °C to + 120 °C
aggressive liquids which do not contain any solids. So they are Intermediate values can be interpolated.
suitable for: Please observe:
drinking water supply for communities Technical rules and safety regulations.
Casing pressure = positive suction pressure + zero delivery
general water supply in agriculture, business and industry head
irrigation and drainage
sprinkling Position of branches:
pumping of condensate Suction branch directed axially, discharge branch directed
charge and discharge of fuels and oils radially upwards.
Please observe: the max. geodetical suction height amounts
to 5 m, provided that the necessary Flanges:
pressure corresponding to NPSH is not
exceeded. The flanges correspond to DIN 2533/2532 PN 16/101) .
Flange design drilled accord. to ANSI 150 is possible.
Speed:
n = 1450 rpm; Designation of this construction type: A .
n = 2900 rpm; Designation of this construction type: B .
DESIGN Bearing:
Two greased antifriction bearings. First grease filling will be
Horizontal, self-priming single stage volume casing pumps with made in the factory.. Designation of this construction type: .B
dimensions and nominal outputs accord. to DIN 24255/EN 733 in As special design oil lubrification is possible.
back pull out construction.
The back pull out construction allows the demounting of the Sense of rotation:
complete bearing unit towards the drive side so that it is not
necessary to detach the pump casing out of the pipings. On ap- Clockwise when seen on the pump from the drive.
plying a coupling with dismounting piece it will be superfluous to
detach the motor. Shaft sealing:
The programme consists of 27 sizes with 4 suction sizes and
needs only 2 shaft units on applying the mechanical assembly The shaft sealing is made by a standard mechanical seal.
technique. Designation AAE: uncooled, not balanced single standard
Within a shaft unit, shaft sealing, impeller fastening and bearing mechanical seal, flushed from internal
cover are exchangeable. source, O-rings Perbunan.
The side channel suction stage is arranged at the drive side of the Temperature range: -40 °C up to +120 °C
volute casing. It is connected in parallel to the liquid pumping
stage and works according to the sucking through principle. Designation AA1: as per AAE, but O-rings Viton.
Temperature range: -40 °C up to +140 °C
0A 0C 3B
21.00 shaft X 20 Cr 13 X 5 Cr Ni Mo 18 10
Casing seal:
For casing sealing a flat type seal of special paper is used. Designation of this construction type: 2
Suction stage I II II IV
Size 32-125 32-160 32-200 50-200 50-250 65-160 65-250 80-200 80-250 32-250 40-250 40-315
32-250 40-125 40-200 65-200 80-160 100-200 100-250 50-250 50-315 65-250
40-250 50-125 50160 65-315 80-200 80-250
65-125 80-315 100-200 100-250
100-315 125-250
Characteristic design B A
The suction stages have been co-ordinated to the different construction sizes in such a manner that an optimal time at an economical drive
power will be attained. On selecting of the motor size for the pump unit this constant drive power is to be considered.
The max. speed of n = 3000 rpm resp. n = 1800 rpm results from the admitted peripheral speed of GG-impellers of 40 m/s resp. from the max.
pumping pressure of 10 bar, as well as from the admitted stress of the suction stage.
General comments:
2
Sectional drawing and nomenclature
3
Performance graph 50 Hz
n = 2900 rpm
n = 1450 rpm
4
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves
motor power =
P + 0,3 kW
motor power =
P + 0,3 kW
5
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves
motor power =
motor power = P + 0,3 kW
P + 0,3 kW
6
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves
motor power =
P + 0,3 kW
motor power =
P + 0,3 kW
7
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves
motor power =
motor power = P + 0,9 kW
P + 0,3 kW
motor power =
P + 0,9 kW
motor power =
P + 2,2 kW
8
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves
motor power =
motor power = P + 2,2 kW
P + 0,9 kW
motor power
P + 2,2 kW motor power =
P + 2,2 kW
9
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves
motor power =
P + 2,2 kW
n = 1450 rpm
10
Characteristic curves n = 1450 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves
motor power =
P + 0,7 kW motor power =
P + 0,7 kW
11
Characteristic curves n = 1450 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves
motor power =
P + 0,7 kW
motor power =
P + 0,7 kW
12
Characteristic curves n = 1450 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves
motor power =
P + 0,7 kW
motor power =
P + 0,7 kW
13
Description:
............. piece Liquid to be handled: ...........................
Temperature: °C ..................
VOLUTE CASING PUMPS Capacity Q m³/h ...................
self-priming, acc. to DIN 24255 Delivery head H m ...................
Power absorption of the pump kW ...................
Maket: Sterling SIHI Speed n 1/min ................
Motor pwer kW ................
For handling of pure respectively turbid not aggressive liquids
which do not contain solids. Scope of delivery: pump unit complete, i.e. pump incl. three-
phase AC motor 220 V resp. 380 V, 50 Hz, protection type
Volute casing , casing cover and stage casing of GG-25 respectively IP 54, incl. common base plate for pump and motor with flexible
cast tin bronze *, impeller of GG-25 respectively cast tin bronze*, coupling.
vane wheel impeller of brass, shaft of 13% chrome steel with shaft seal
by not balanced single standard mechanical seal of material combina
tion Cr Ni/carbon, Perbunan resp. Viton for the following operation data:
Price for piece DM ..................
14
Dimension table
15
Foundation plan n = 2900 rpm
minimum lenght
of rag bolt
Dimensions in mm, tolerances (base plates) for cast pieces DIN 1686/GTB 17,
for welded pieces acc. to DIN 8570 B
base plate
motor coup- weight rag bolt
size size kW Nr. ling pump unit a b2 c e1 e2 e4 f1 h h3 l p1 p2 w* w1 ue DIN 529
**kg
kg
32-125 71 b 0,55 P 241 A 10 23 52 80 330 25 480 290 115 60 65 177 710 - 41 678 730 G1/2 M 16 x 200
80 a 0,75 55 32 687
80 b 1,1 56 702
90 S 1,5 59 22 742
90 L 2,2 63 767
32-160 80 b 1,1 26 59 52 702
90 S 1,5 63 197 42 742
90 L 2,2 67 767
100 L 3,0 P 272 77 360 540 320 130 800 32 826 820
112 M 4,0 A 25 95 20 826
32-200 90 L 2,2 P 241 A 10 30 71 330 480 290 115 225 710 70 767 730
100 L 30, P 272 81 360 540 320 130 800 60 826 820
112 M 4,0 A 25 99 48 826
13S 5,5 A 63 117 28 909
132 S 7,5 120 909
32-250 132 S 7,5 P 342 48 148 100 450 30 540 400 130 75 80 260 800 48 929 820
160 M 11,0 P 344 207 660 170 1000 20 1094 1020 M 20 x 200
160 M 15,0 209 1094
40-125 80 b 1,1 P 241 A 10 24 57 80 330 25 480 290 115 60 65 177 710 32 702 730 M 16 x 200
90 S 1,5 61 22 742
90 L 2,2 65 767
100 L 3,0 P 272 74 360 540 320 130 800 12 826 820
40-160 90 S 1,5 P 241 27 64 330 480 290 115 197 710 42 742 730
90 L 2,2 68 767
100 L 30, P 272 78 360 540 320 130 800 32 826 820
112 M 4,0 A 25 96 20 826
132 S 5,5 A 63 113 - 909
40-200 100 L 3,0 A 10 34 85 100 60 846
112 M 4,0 A 25 103 225 48 846
132 S 5,5 A 63 121 28 929
132 S 7,5 124 929
160 M 11,0 P 344 198 450 30 660 400 170 80 240 1000 - 1094 1020 M 20 x 200
40-250 132 S 7,5 42 156 75 260 48 929
160 M 11,0 207 20 1094
160 M 15,0 209 1094
160 L 18,5 232 1138
50-125 90 S 1,5 P 241 A 10 26 63 100 330 25 480 290 115 60 65 197 710 42 762 730 M 16 x 200
90 L 2,2 67 787
100 L 3,0 P 272 77 360 540 320 130 800 32 846 820
112 M 4,0 A 25 95 20 846
132 S 5,5 A 63 112 - 929
50-160 90 L 2,2 P 301 A 10 31 77 390 480 350 115 710 70 787 730
100 L 3,0 P 272 82 360 540 320 130 225 800 60 846 820
112 M 4,0 A 25 100 48 846
132 S 5,5 A 63 118 28 929
132 S 7,5 121 30 660 170 80 240 1000 929
160 M 11,0 P 344 195 25 540 130 65 225 800 - 1094 1020 M 20 x 200
50-200 100 L 3,0 P 272 A 10 35 87 60 846 820
112 M 4,0 A 25 105 48 846
132 S 5,5 P 342 A 63 134 450 30 400 75 80 240 28 929
132 S 7,5 137 929
160 M 11,0 P 344 199 660 170 1000 - 1094 1020
160 M 15,0 201 1094
50-250 160 M 11,0 43 208 20 1094
160 M 15,0 210 1094
160 L 18,5 233 1138
180 M 22,0 S 385 A 100 292 490 40 740 440 190 110 290 1120 -- 1165 - -
200 L 30,0 A 160 388 310 20 1263
16
Foundation plan n = 2900 rpm
* motors-type of enclosure IP 54, dimensions dependent on motor make ** PKZ-coupling dynamically balanced
17
Foundation plan n = 1450 rpm
minimum lenght
of rag bolt
Dimensions in mm, tolerances (base plates) for cast pieces acc. to DIN 1686/GTB 17,
for welded pieces acc. to DIN 8570 B
18
Foundation plan for units with spacer type coupling n = 2900 rpm
minimum lenght
of rag bolt
Dimensions in mm, tolerances (base plate) for cast pieces acc. to DIN 1686/GTB 17,
for welded pieces acc. to DIN 8570 B
19
Foundation plan for units with spacer type coupling n = 2900 rpm
base
motor plate coup- weight rag bolt
size size kW Nr. ling pum unit a b2 c e1 e2 e4 f1 h h3 l p1 p2 w* w1 ue x DIN 529
PKA p kg kg
65-125 100 L 3,0 P 303 8 29 95 100 390 25 600 350 150 75 65 225 900 - 60 950 920 G1/2 100 M 16 x 160
112 M 4,0 112 48 965
132 S 5,5 127 28 1030
132 S 7,5 9 131
65-160 132 S 5,5 8 34 132
132 S 7,5 9 139
160 M 11,0 P 344 200 450 30 660 400 170 65 80 240 1000 - 1200 1020 M 20 x 250
160 M 15,0 10 204
65-200 160 M 11,0 9 38 204 260 20
160 L 18,5 S 385 10 269 490 40 740 440 190 75 110 290 1120 1250 - -
180 M 22,0 12 292 - 1280
200 L 30,0 P 436 378 540 30 840 490 205 80 280 1250 20 1380 1270 G1/2
65-250 160 L 18,5 S 386 10 62 402 490 40 440 90 110 310 - 40 1340 - -
180 M 22,0 12 326 20 1385
200 L 30,0 S 487 416 610 940 550 230 100 300 1400 - 1485 M 24 x 400
200 L 37,0 14 430
225 M 45,0 15 512 325 25 1540
80-160 132 S 7,5 P 344 9 39 154 125 450 30 660 400 170 80 260 1000 - 48 1055 1020 G1/2 M 20 x 250
160 M 11,0 205 65 20 1225
160 M 15,0 10 209
160 L 18,5 S 385 269 490 40 740 440 190 75 110 290 1120 1270 - -
180 M 22,0 12 293 - 1305
80-200 160 M 15,0 10 56 263 20 1335
160 L 18,5 S 386 296 840 1250 1380
180 M 22,0 12 320 - 1410
200 L 30,0 S 486 410 610 940 550 230 100 300 1400 20 1510 M 24 x 400
200 L 37,0 14 424
80-250 180 M 22,0 S 486 12 69 324 840 205 90 1250 - 20 1410
200 L 30,0 S 487 424 940 230 1400 - 1510
200 L 37,0 14 437
225 M 45,0 15 519 325 25 1565
250 M 55,0 S 606 650 730 1060 670 270 350 1600 50 1685
100-200 160 L 18,5 S 386 12 65 312 490 840 440 205 110 310 1250 40 1420 140 M 20 x 250
180 M 22,0 322 20 1450
200 L 30,0 S 487 422 610 940 550 230 100 300 1400 - 1550 M 24 x 400
200 L 37,0 14 435
225 M 45,0 15 518 325 25 1605
100-250 200 L 30,0 12 78 435 140 - 25 1565
200 L 37,0 14 448
225 M 45,0 15 531 - 1620
250 M 55,0 S 608 661 730 1060 670 270 350 1600 25 1740
280 S 75,0 17 842 380 55 1820
280 M 90,0 20 892 1825
20
Foundation plan for units with spacer type coupling n = 1450 rpm
minimum lenght
of rag bolt
Dimensions in mm, tolerances (base plate) for cast pieces acc. to DIN 1686/GTB 17,
for welded pieces acc. to DIN 8570 B
base
motor plate coup- weight rag bolt
size size kW Nr. ling pump unit a b2 c e1 e2 e4 f1 h h3 l p2 w* w1 ue x DIN 529
PKA kg kg
32-250 80 b 0,75 P 342 8 40 100 100 450 30 540 400 130 75 80 260 800 100 840 820 G1/2 100 M 20 x 250
90 S 1,1 104 90 870
90 L 1,5 108 895
100 L 2,2 P 383 118 490 600 440 150 900 80 950 920
40-250 90 S 1,1 P 342 8 42 106 100 450 30 540 400 130 75 80 260 800 90 870 820 G1/2 100 M 20 x 250
90 L 1,5 110 985
100 L 2,2 P 383 122 490 600 150 900 80 950 920
100 L 3,0 125
40-315 100 L 2,2 S 385 78 174 125 740 190 110 335 1120 125 1080 - -
100 L 3,0 177
112 M 4,0 9 196 113 1090
132 S 5,5 211 93 1165
50-250 90 L 1,5 P 342 8 43 111 100 450 30 540 400 130 75 80 260 900 90 895 920 G1/2 100 M 20 x 250
100 L 2,2 P 383 123 490 600 440 150 80 950
100 L 3,0 126
112 M 4,0 9 145 68 1000
50-315 112 M 4,0 S 385 80 225 125 40 740 190 110 335 1120 113 1090 - -
132 S 5,5 235 93 1165
132 M 7,5 10 253 1200
65-250 100 L 2,2 P 343 8 62 155 100 540 30 660 490 170 90 80 280 1000 100 1060 1020 G1/2 100 M 20 x 250
100 L 3,0 158
112 M 4,0 9 176 88 1070
132 S 5,5 S 385 221 125 490 40 740 440 190 110 310 1120 68 1140 - -
65-315 132 S 5,5 87 241 335 93 1165
132 M 7,5 10 258 1200
160 M 11,0 S 386 12 310 840 205 1250 65 1330
160 L 15,0 335 1375
80-200 90 L 1,5 P 434 8 56 128 125 540 30 660 490 170 75 80 260 1000 90 1035 1020 G1/2 100 M 20 x 250
100 L 2,2 146 80 1080
100 L 3,0 148
112 M 4,0 9 169 68 1090
132 S 5,5 184 48 1165
80-250 100 L 3,0 8 69 164 90 280 100 1080
112 M 4,0 9 183 88 1090
132 S 5,5 S 385 219 490 40 740 440 190 110 310 1120 68 1165 - -
132 M 7,5 10 235 1200
80-315 132 S 5,5 9 92 245 360 118 1165
132 M 7,5 10 263 1200
160 M 11,0 S 386 12 311 840 205 1250 90 1330
160 L 15,0 335 1375
100-200 100 L 2,2 P 434 8 65 163 125 540 30 660 490 170 90 80 280 1000 100 1125 1020 G1/2 140 M 20 x 250
100 L 3,0 166
112 M 4,0 S 385 9 203 490 40 740 440 190 110 310 1120 88 1135 - -
132 S 5,5 218 68 1210
132 M 7,5 10 238 1245
100-250 112 M 4,0 9 78 220 140 335 113 1150
132 S 5,5 235 93 1220
132 M 7,5 10 253 1260
160 M 11,0 S 386 12 305 840 205 1250 65 1390
100-315 160 M 11,0 97 321 90
160 L 15,0 346 360 1430
180 M 18,5 14 370 70 1460
180 L 22,0 15 395 80 1500
125-250 132 M 7,5 S 385 10 97 273 140 490 40 740 440 190 90 110 360 1120 118 1260 - - 140 M 20 x 250
160 M 11,0 S 386 12 321 840 205 1250 90 1390
160 L 15,0 347 1430
21
Data regarding size - order notes
Series + Hydraulic+ bearing Shaft seal Material design Casing seal
size
A. speed n = 1450 rpm AAE standard mechanical seal 0A standard design cast iron
B. speed n = 2900 rpm O-rings Perbunan 0C as per 0A, but impeller of 2 flat seals
.B two greased AA1 as per AAE, but G-CuSn 10
O-rings Viton 3B main parts of G-CuSn 10
antifriction bearing
32-125 BB
32-160 BB
32-200 BB
32-250 AB
32-250 BB
40-125 BB
40-160 BB
40-200 BB
40-250 AB
40-250 BB
40-315 AB
50-125 BB
50-160 BB
50-200 BB
50-250 AB
50-250 BB alternatively
ULN 50-315 AB alternatively 0A
65-125 BB AAE 0C 2
65-160 BB AA1 3B
65-200 BB
65-250 AB
65-250 BB
65-315 AB
80-160 BB
80-200 AB
80-200 BB
80-250 AB
80-250 BB
80-315 AB
100-200 AB
100-200 BB
100-250 AB
100-250 BB
100-315 AB
125-250 AB
pump with free shaft end 01 motor n = 2900 rpm motor n = 1450 rpm
pump with coupling, ready drilled at motor side kW size designation kW size designation
and coupling guard for the shaft coupling 41 0,55 71 b EA 0,25 71 a DB
as above, but pump and coupling guard for the 0,75 80 a FA 0,37 71 b EB
shaft coupling, mounted on base plate, 1,1 80 b GA 0,55 80 a FB
incl. supports for pump and motor and 1,5 90 S HA 0,75 80 b GB
1 set of rag bolts 53 2,2 90 L JA 1,1 90 S HB
as above, but with motor 3,0 100 L KA 1,5 90 L JB
e.g. 18,5 kW-three-phase AC motor e.g. UA 4,0 112 M MA 2,2 100 L KB
(50 Hz, 380 V) V9 V), rpm
at 2900 5,5 132 S NA 3,0 100 L LB
7,5 132 S OA 4,0 112 M MB
11 160 M SA 5,5 132 S NB
15 160 M TA 7,5 132 M PB
Important: 18,5 160 L UA 11 160 M SB
In case of order please indicate always output 22 180 M VA 15 160 L UB
Q m³/h and delivery head H m . 30 200 L XA 18,5 180 M VB
37 200 L YA 22 180 L WB
45 225 M AA
55 250 M BA
75 280 S CA
90 280 M DA
Example for ordering:
The size ULN 65-250 BB AAE 0A 2 with coupling, pre-drilled at the motor side and coupling guard
for the shaft coupling has the complete order number: ULN . 65-250 BB AAE 0A 2 41
The size ULN 65-250 BB AAE 0A 2 as complete unit with 18,5 kW three-phase AC motor, 2900 rpm
has the complete order number: ULN . 65-250 BB AAE 0A 2 UA
On delivery, the period ( . )at the fourth place of the type designation is replaced by a letter in the factory.
On ordering the designs 41 and 53 please indicate always the provided motor in order that the coupling can be ready drilled at motor side and
choose the correct base plate and to enclose the proper documentation.
On request, the bearing bracket can be delivered in oil-lubricated design against additional costs-please indicate extra.
Any changes in the interest of the technical development are reserved.
22
Sterling SIHI (Spain), S.A.
Vereda de los Zapateros s/n, Pozuelo de Alarcón 28223 Madrid, Spain.
Telephone +34 91 709 1310 Telefax +34 91 715 9700
www.sihi.com
23