Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Curve Pompa

Download as pdf or txt
Download as pdf or txt
You are on page 1of 23

Volute Casing Pumps

self-priming

ULN 32-125 . . . 125-250

TECHNICAL DATA

Output: max. 300 m³/h


Head: max. 95 m
Suction head: max. 5 m (cold water)
Speed: max. 3000 rpm
Temperature: max. 120 °C
Casing pressure: PN 10
Shaft sealing: standard mechanical seal
Flange connections: DIN 2501 PN 10
Sense of rotation: clockwise when seen on the
pump from the drive

APPLICATION CONSTRUCTION

The self-priming volute casing pumps according to DIN 24255 of Casing pressure:
the series ULN are applied when it is necessary to suck in and to
handle without problems and automatically, pure resp. turbid not Max. 10 bar from -40 °C to + 120 °C
aggressive liquids which do not contain any solids. So they are Intermediate values can be interpolated.
suitable for: Please observe:
drinking water supply for communities Technical rules and safety regulations.
Casing pressure = positive suction pressure + zero delivery
general water supply in agriculture, business and industry head
irrigation and drainage
sprinkling Position of branches:
pumping of condensate Suction branch directed axially, discharge branch directed
charge and discharge of fuels and oils radially upwards.
Please observe: the max. geodetical suction height amounts
to 5 m, provided that the necessary Flanges:
pressure corresponding to NPSH is not
exceeded. The flanges correspond to DIN 2533/2532 PN 16/101) .
Flange design drilled accord. to ANSI 150 is possible.

Speed:
n = 1450 rpm; Designation of this construction type: A .
n = 2900 rpm; Designation of this construction type: B .

DESIGN Bearing:
Two greased antifriction bearings. First grease filling will be
Horizontal, self-priming single stage volume casing pumps with made in the factory.. Designation of this construction type: .B
dimensions and nominal outputs accord. to DIN 24255/EN 733 in As special design oil lubrification is possible.
back pull out construction.
The back pull out construction allows the demounting of the Sense of rotation:
complete bearing unit towards the drive side so that it is not
necessary to detach the pump casing out of the pipings. On ap- Clockwise when seen on the pump from the drive.
plying a coupling with dismounting piece it will be superfluous to
detach the motor. Shaft sealing:
The programme consists of 27 sizes with 4 suction sizes and
needs only 2 shaft units on applying the mechanical assembly The shaft sealing is made by a standard mechanical seal.
technique. Designation AAE: uncooled, not balanced single standard
Within a shaft unit, shaft sealing, impeller fastening and bearing mechanical seal, flushed from internal
cover are exchangeable. source, O-rings Perbunan.
The side channel suction stage is arranged at the drive side of the Temperature range: -40 °C up to +120 °C
volute casing. It is connected in parallel to the liquid pumping
stage and works according to the sucking through principle. Designation AA1: as per AAE, but O-rings Viton.
Temperature range: -40 °C up to +140 °C

PUMP TECHNOLOGY ULN P III/1


133.85210.53.01 E 08/2015
Material design

Item COMPONENTS MATERIAL DESIGN

0A 0C 3B

10.20 volute casing

10.90, 11.40 stage casing GG-25 G-CuSn 10

16.10 casing cover

21.00 shaft X 20 Cr 13 X 5 Cr Ni Mo 18 10

23.00 impeller GG 25 G-Cu Sn 10

23.50 vane wheel impeller So Ms die-pressed chrom-platet

33.00 bearing bracket GG-25

43.30 shaft sealing mechanical seal X 22 Cr Ni 17 / carbon, Perbunan X 22 Cr Ni 17 / carbon, Viton

47.10 shaft sealing casing GG-25 G-Cu Sn 10

Casing seal:

For casing sealing a flat type seal of special paper is used. Designation of this construction type: 2

Drive / Speed and co-ordination of the suction stages:

Drive by commercial electric motors, construction type IM B3.


Drive by V-belt is admitted up to 1,5 kW drive power. On request, drive by Diesel engines or gasoline motors.

Suction stage I II II IV

Size 32-125 32-160 32-200 50-200 50-250 65-160 65-250 80-200 80-250 32-250 40-250 40-315
32-250 40-125 40-200 65-200 80-160 100-200 100-250 50-250 50-315 65-250
40-250 50-125 50160 65-315 80-200 80-250
65-125 80-315 100-200 100-250
100-315 125-250

Additional drive power 0,3 0,9 2,2 0,7


kW

Speed rpm 2900 1450

Max. speed rpm 300 1800

Characteristic design B A

The suction stages have been co-ordinated to the different construction sizes in such a manner that an optimal time at an economical drive
power will be attained. On selecting of the motor size for the pump unit this constant drive power is to be considered.
The max. speed of n = 3000 rpm resp. n = 1800 rpm results from the admitted peripheral speed of GG-impellers of 40 m/s resp. from the max.
pumping pressure of 10 bar, as well as from the admitted stress of the suction stage.

General comments:

For self-priming multistage segmental type pumps we refer to the

series TKH and TLH

Technical documentation about these programmes will be readily supplied on request.

2
Sectional drawing and nomenclature

10.20 volute casing 23.00 impeller 43.30 mechanical seal


10.90, 11.40 stage casing 23.50 vane wheel impeller 47.10 shaft sealing casing
16.10 casing cover 32.00 inclined ball bearing 71.10 ventilation line
18.30 support foot 32.10 grooved ball bearing 73.10, 73.11 pipe union with
21.00 shaft 33.00 bearing bracket 75.70 orifice plate

Advices for the installation


The pipeline on suction side has to be installed as shown,
above pump centre, so that sufficient quantity of liquid for
the self suction procedure is available.

The ejection of the


sucked in air (gas)
into the atmosphere,
into the suction tank
or into the discharge
line.

3
Performance graph 50 Hz
n = 2900 rpm

n = 1450 rpm

4
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves

motor power = motor power =


P + 0,3 kW P + 0,3 kW

motor power =
P + 0,3 kW
motor power =
P + 0,3 kW

5
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves

motor power =
motor power = P + 0,3 kW
P + 0,3 kW

motor power = motor power =


P + 0,3 kW P + 0,3 kW

6
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves

motor power =
P + 0,3 kW

motor power =
P + 0,3 kW

motor power = motor power =


P + 2,2 kW P + 2,2 kW

7
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves

motor power =
motor power = P + 0,9 kW
P + 0,3 kW

motor power =
P + 0,9 kW
motor power =
P + 2,2 kW

8
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves

motor power =
motor power = P + 2,2 kW
P + 0,9 kW

motor power
P + 2,2 kW motor power =
P + 2,2 kW

9
Characteristic curves n = 2900 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves

max. motor power

motor power =
P + 2,2 kW

n = 1450 rpm

motor power = motor power =


P + 0,7 kW P + 0,7 kW

10
Characteristic curves n = 1450 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves

motor power = motor power =


P + 0,7 kW P + 0,7 kW

motor power =
P + 0,7 kW motor power =
P + 0,7 kW

11
Characteristic curves n = 1450 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves

motor power = motor power =


P + 0,7 kW P + 0,7 kW

motor power =
P + 0,7 kW

motor power =
P + 0,7 kW

12
Characteristic curves n = 1450 rpm
Attention: On selecting the motors, the constant drive power of the pertinent suction stage has to be added to the drive values determined out
of the characteristic curves

motor power = motor power =


P + 0,7 kW P + 0,7 kW

motor power =
P + 0,7 kW
motor power =
P + 0,7 kW

Values are applicable for water  = 1kg/l

13
Description:
............. piece Liquid to be handled: ...........................
Temperature: °C ..................
VOLUTE CASING PUMPS Capacity Q m³/h ...................
self-priming, acc. to DIN 24255 Delivery head H m ...................
Power absorption of the pump kW ...................
Maket: Sterling SIHI Speed n 1/min ................
Motor pwer kW ................
For handling of pure respectively turbid not aggressive liquids
which do not contain solids. Scope of delivery: pump unit complete, i.e. pump incl. three-
phase AC motor 220 V resp. 380 V, 50 Hz, protection type
Volute casing , casing cover and stage casing of GG-25 respectively IP 54, incl. common base plate for pump and motor with flexible
cast tin bronze *, impeller of GG-25 respectively cast tin bronze*, coupling.
vane wheel impeller of brass, shaft of 13% chrome steel with shaft seal
by not balanced single standard mechanical seal of material combina
tion Cr Ni/carbon, Perbunan resp. Viton for the following operation data:
Price for piece DM ..................

*Please delete which is inapplicable Weight per piece kg ..................

14
Dimension table

III = connection for air ventilation pipe G 3/8


uAL = connection for leak liquid G ¼
ue = connection for discharge G ¼ from DNA 65 G 3/8

1) Pipe bend can be delivered as accessory by the factory.

size DNA DNE a b c f H h1 h2 h3 m1 m2 n1 n2 s w x d1 l t u

32-125 32 50 80 50 15 360 25 112 140 73 100 70 190 140 15 267 80 24 50 27 8


32-160 132 160 240 190
32-200 160 180
32-250 100 65 32,5 180 225 125 95 320 250 342 100 32 80 35 10

40-125 40 65 80 50 112 140 100 70 210 160 267 80 24 50 27 8


40-160 132 160 240 190
40-200 100 160 180 265 212
40-250 65 180 225 125 95 320 250
40-315 125 18 470 225 250 87 345 280 340 100 32 80 35 10
50-125 50 100 50 15 360 132 160 73 100 70 240 190 267 80 24 50 27 8
50-160 160 180 265 212
50-200 200 125 95
50-200 65 180 225 320 250
50-315 125 18 470 225 280 87 345 280 340 100 32 80 35 10

65-125 65 80 100 15 360 40 160 180 73 280 212 267 80 24 50 27 8


65-160 200
65-200 180 225 320 250 100
65-250 80 470 200 250 87 160 120 360 280 19 340 32 80 35 10
65-315 125 18 225 280 400 315
80-160 80 100 65 15 360 50 180 225 73 125 95 320 250 15 267 24 50 27 8
80-200 470 250 87 345 280 340 32 80 35 10
80-250 80 18 200 280 160 120 400 315 19
80-315 250 315

100-200 100 125 62,5 200 280 120


100-250 140 225 400 315
100-315 250 315
125-250 125 150 75 355

Flange connections acc. to DIN 2501 PN 16 and PN 10


DNA/DNE 32 40 50 65 80 100 125 150
D 140 150 165 185 200 220 250 285
k 100 110 125 145 160 180 210 240
d2 x number 18x4 18x4 18x4 18x4 18x8 18x8 18x8 22x8

15
Foundation plan n = 2900 rpm

minimum lenght
of rag bolt

Dimensions in mm, tolerances (base plates) for cast pieces DIN 1686/GTB 17,
for welded pieces acc. to DIN 8570 B

base plate
motor coup- weight rag bolt
size size kW Nr. ling pump unit a b2 c e1 e2 e4 f1 h h3 l p1 p2 w* w1 ue DIN 529
**kg
kg
32-125 71 b 0,55 P 241 A 10 23 52 80 330 25 480 290 115 60 65 177 710 - 41 678 730 G1/2 M 16 x 200
80 a 0,75 55 32 687
80 b 1,1 56 702
90 S 1,5 59 22 742
90 L 2,2 63 767
32-160 80 b 1,1 26 59 52 702
90 S 1,5 63 197 42 742
90 L 2,2 67 767
100 L 3,0 P 272 77 360 540 320 130 800 32 826 820
112 M 4,0 A 25 95 20 826
32-200 90 L 2,2 P 241 A 10 30 71 330 480 290 115 225 710 70 767 730
100 L 30, P 272 81 360 540 320 130 800 60 826 820
112 M 4,0 A 25 99 48 826
13S 5,5 A 63 117 28 909
132 S 7,5 120 909
32-250 132 S 7,5 P 342 48 148 100 450 30 540 400 130 75 80 260 800 48 929 820
160 M 11,0 P 344 207 660 170 1000 20 1094 1020 M 20 x 200
160 M 15,0 209 1094
40-125 80 b 1,1 P 241 A 10 24 57 80 330 25 480 290 115 60 65 177 710 32 702 730 M 16 x 200
90 S 1,5 61 22 742
90 L 2,2 65 767
100 L 3,0 P 272 74 360 540 320 130 800 12 826 820
40-160 90 S 1,5 P 241 27 64 330 480 290 115 197 710 42 742 730
90 L 2,2 68 767
100 L 30, P 272 78 360 540 320 130 800 32 826 820
112 M 4,0 A 25 96 20 826
132 S 5,5 A 63 113 - 909
40-200 100 L 3,0 A 10 34 85 100 60 846
112 M 4,0 A 25 103 225 48 846
132 S 5,5 A 63 121 28 929
132 S 7,5 124 929
160 M 11,0 P 344 198 450 30 660 400 170 80 240 1000 - 1094 1020 M 20 x 200
40-250 132 S 7,5 42 156 75 260 48 929
160 M 11,0 207 20 1094
160 M 15,0 209 1094
160 L 18,5 232 1138
50-125 90 S 1,5 P 241 A 10 26 63 100 330 25 480 290 115 60 65 197 710 42 762 730 M 16 x 200
90 L 2,2 67 787
100 L 3,0 P 272 77 360 540 320 130 800 32 846 820
112 M 4,0 A 25 95 20 846
132 S 5,5 A 63 112 - 929
50-160 90 L 2,2 P 301 A 10 31 77 390 480 350 115 710 70 787 730
100 L 3,0 P 272 82 360 540 320 130 225 800 60 846 820
112 M 4,0 A 25 100 48 846
132 S 5,5 A 63 118 28 929
132 S 7,5 121 30 660 170 80 240 1000 929
160 M 11,0 P 344 195 25 540 130 65 225 800 - 1094 1020 M 20 x 200
50-200 100 L 3,0 P 272 A 10 35 87 60 846 820
112 M 4,0 A 25 105 48 846
132 S 5,5 P 342 A 63 134 450 30 400 75 80 240 28 929
132 S 7,5 137 929
160 M 11,0 P 344 199 660 170 1000 - 1094 1020
160 M 15,0 201 1094
50-250 160 M 11,0 43 208 20 1094
160 M 15,0 210 1094
160 L 18,5 233 1138
180 M 22,0 S 385 A 100 292 490 40 740 440 190 110 290 1120 -- 1165 - -
200 L 30,0 A 160 388 310 20 1263

16
Foundation plan n = 2900 rpm

motor base plate coup- weight rag bolt


size size kW Nr. ling pump unit a b2 c e1 e2 e4 f1 h h3 l p1 p2 w* w1 ue DIN 529
kg
kg
65-125 100 L 3,0 P 342 A 10 29 95 100 450 30 540 400 130 75 80 240 800 - 60 846 820 G1/4 M 20 x 200
112 M 4,0 A 25 113 48 846
132 S 5,5 P 303 A 63 127 390 25 600 350 150 65 225 900 28 929 920 M 16 x 200
132 S 7,5 130 929
65-160 132 S 5,5 34 132 929
132 S 7,5 135 929
160 M 11,0 P 344 198 450 30 660 400 170 80 240 1000 - 1094 1020 M 20 x200
160 M 15,0 200 1094
65-200 160 M 11,0 38 203 260 20 1094
160 M 15,0 205 1094
160 L 18,5 228 1138
180 M 22,0 S 385 A 100 287 490 40 740 440 190 110 290 1120 - 1165 - -
200 L 30,0 A 160 382 310 20 1263
65-250 160 L 18,5 A 63 62 289 90 - 40 1248
180 M 22,0 A 100 311 20 1275
200 L 30,0 S 386 A 160 417 840 205 1250 - 1373
200 L 37,0 427 1373
225 M 45,0 S 486 510 610 550 106 325 33 1432 M 24 x 250
80-160 132 S 7,5 P 342 A 63 39 144 125 450 30 540 400 130 75 80 260 800 - 48 954 820 G1/2 M 20 x 200
160 M 11,0 P 344 203 660 170 1000 20 1119 1020
160 M 15,0 205 1119
160 L 18,5 228 1163
180 M 22,0 S 385 A 100 287 490 40 740 440 190 110 290 1120 - 1190 - -
80-200 160 M 15,0 A 63 56 260 20 1229
160 L 18,5 283 1273
180 M 22,0 A 100 305 - 1300
200 L 30,0 S 386 A 160 411 840 205 310 1250 20 1398
200 L 37,0 421 1398
80-250 180 M 22,0 S 385 A 100 69 319 740 190 90 1120 - 20 1300
200 L 30,0 S 386 A 160 424 840 205 1250 - 1398
200 L 37,0 434 1398
225 M 45,0 S 486 504 610 550 106 325 33 1457 M 24 x 250
250 M 55,0 S 487 A 250 611 940 230 350 1400 58 1577
100-200 160 L 18,5 S 385 A 63 65 299 140 490 40 740 440 190 110 310 1120 40 1273 - - M 20 x 200
180 M 22,0 A 100 314 20 1300
200 L 30,0 S 386 A 160 420 840 205 1250 - 1398
200 L 37,0 430 1398
225 M 45,0 S 486 503 610 550 106 33 1457 M 24 x 250
100-250 200 L 30,0 S 386 78 440 490 440 110 325 - 25 1413 M 20 x 200
200 L 37,0 450 940 1413
225 M 45,0 S 486 525 610 550 106 8 - 1472 M 24 x 250
250 M 55,0 S 487 A 250 621 230 350 1400 33 1592
280 S 75,0 S 607 PKZ 17 822 730 695 100 380 55 1676
**
280 M 90,0 PKZ 20 868 1727
**

* motors-type of enclosure IP 54, dimensions dependent on motor make ** PKZ-coupling dynamically balanced

17
Foundation plan n = 1450 rpm

minimum lenght
of rag bolt

Dimensions in mm, tolerances (base plates) for cast pieces acc. to DIN 1686/GTB 17,
for welded pieces acc. to DIN 8570 B

motor base plate coup- weight rag bolt


size size kW Nr. ling pump unit a b2 c e1 e2 e4 f1 h h3 l p2 w* w1 ue DIN 529
kg kg
32-250 80 b 0,75 P 342 A 10 40 92 100 450 30 540 400 130 60 80 260 800 100 722 820 G1/2 M 20 x 200
90 S 1,1 96 90 762
90 L 1,5 100 787
100 L 2,2 A 25 108 80 846
40-250 90 S 1,1 P 342 A 10 42 99 100 450 30 540 400 130 73 80 260 800 90 762 820 G1/2 M 20 x 200
90 L 1,5 103 787
100 L 2,2 A 25 110 80 846
100 L 3,0 111 846
40-315 100 L 2,2 P 383 78 153 125 490 600 440 150 75 305 900 125 981 920
100 L 3,0 154 981
112 M 4,0 A 63 172 113 981
132 S 5,5 194 93 1064
50-250 90 L 1,5 P 342 A 10 43 104 100 450 30 540 400 130 75 80 260 800 90 787 820 G1/2 M 20 x 200
100 L 2,2 A 25 111 80 846
100 L 3,0 112 846
112 M 4,0 A 63 130 68 846
50-315 112 M 4,0 P 383 80 174 125 490 600 400 150 305 900 113 981 920
132 S 5,5 196 93 1064
132 M 7,5 S 385 246 40 470 190 110 335 1120 1102 - -
65-250 100 L 2,2 P 383 A 25 62 137 100 490 30 600 440 150 90 80 280 900 100 956 920 G1/2 M 20 x 200
100 L 3,0 136 956
112 M 4,0 A 63 156 88 956
132 S 5,5 S 385 216 40 740 190 110 310 1120 68 1039 - -
65-315 132 S 5,5 87 242 125 335 93 1064
132 M 7,5 252 1102
160 M 11,0 A 100 297 65 1229
160 L 15,0 318 1273
80-200 90 L 1,5 P 383 A 25 56 122 125 490 30 600 440 150 75 80 260 900 90 922 920 G1/2 M 20 x 200
100 L 2,2 130 68 981
100 L 3,0 131 981
112 M 4,0 A 63 149 981
132 S 5,5 170 48 1064
80-250 100 L 3,0 S 385 A 25 69 184 40 740 190 100 110 310 1120 100 981 - -
112 M 4,0 A 63 203 88 981
132 S 5,5 224 68 1064
132 M 7,5 234 1102
80-315 132 S 5,5 92 248 360 118 1064
132 M 7,5 258 1102
160 M 11,0 A 100 302 90 1229
160 L 15,0 323 1273
100-200 100 L 2,2 P 383 A 25 65 137 125 490 30 600 440 150 90 80 280 900 100 981 920 G1/2 M 20 x 200
100 L 3,0 140 981
112 M 4,0 A 63 159 88 981
132 S 5,5 S 385 220 40 740 190 110 310 1120 68 1064 - -
132 M 7,5 230 1102
100-250 112 M 4,0 78 212 140 335 113 996
132 S 5,5 234 93 1079
132 M 7,5 244 1117
160 M 11,0 A 100 288 65 1244
100-315 160 M 11,0 97 307 360 90 1244
160 L 15,0 328 1288
180 M 18,5 A 160 348 70 1315
180 L 22,0 369 1353
125-250 132 M 7,5 S 385 A 63 97 263 140 490 40 740 440 190 100 110 360 1120 118 1117 - - M 20 x 200
160 M 11,0 A 100 307 90 1244
160 L 15,0 328 1288

* motors-type of enclosure IP 54, dimensions dependent on motor make

18
Foundation plan for units with spacer type coupling n = 2900 rpm

minimum lenght
of rag bolt

Dimensions in mm, tolerances (base plate) for cast pieces acc. to DIN 1686/GTB 17,
for welded pieces acc. to DIN 8570 B

motor base plate coup- weight rag bolt


size size kW Nr. ling pump unit a b2 c e1 e2 e4 f1 h h3 l p1 p2 w* w1 ue x DIN 529
PKA kg kg
32-125 71 b 0,55 P 241 8 23 55 80 330 25 480 290 115 50 65 177 710 - 41 794 730 G1/2 100 M 16 x 160
80 a 0,75 P 272 62 360 540 320 160 60 800 32 820 820
80 b 1,1 63
90 S 1,5 67 22 850
90 L 2,2 71 880
32-160 80 b 1,1 26 67 197 52 820
90 S 1,5 70 42 850
90 L 2,2 74 880
100 L 3,0 80 50 32 930
112 M 4,0 P 303 108 390 600 350 150 60 900 20 940 920
32-200 90 L 2,2 P 272 30 79 360 540 320 130 225 800 70 880 820
100 L 3,0 85 50 60 930
112 M 4,0 P 303 113 390 600 350 150 60 900 48 940 920
13S 5,5 128 28 1010
132 S 7,5 9 132
32-250 132 S 7,5 P 344 48 173 100 450 30 660 400 170 75 80 260 1000 48 1090 1020
160 M 11,0 214 20 1200 M 20 x 250
160 M 15,0 10 218
40-125 80 b 1,1 P 272 8 24 64 80 360 25 540 320 130 60 65 177 800 32 820 820 M 16 x 160
90 S 1,5 68 22 850
90 L 2,2 72 880
100 L 3,0 78 50 197 12 930
40-160 90 S 1,5 27 71 60 42 850
90 L 2,2 75 880
100 L 3,0 84 50 32 930
112 M 4,0 P 303 109 390 60 900 20 940 920
132 S 5,5 124 - 1010
40-200 100 L 3,0 P 272 34 89 100 360 540 320 130 50 225 800 60 950 820
112 M 4,0 P 303 117 390 600 350 150 60 900 48 960 920
132 S 5,5 9 132 28 1030
132 S 7,5 136
160 M 11,0 P 344 200 450 30 660 400 170 80 240 1000 - 1200 1020 M 20 x 250
40-250 132 S 7,5 42 157 75 260 48 1030
160 M 11,0 208 20 1200
160 M 15,0 10 212
160 L 18,5 S 385 272 490 40 740 440 190 110 290 1120 1250 - -
50-125 90 S 1,5 P 272 8 26 70 360 25 540 320 130 60 65 197 800 42 870 820 M 16 x 200
90 L 2,2 74 900
100 L 3,0 80 50 32 950
112 M 4,0 P 303 108 390 600 350 150 60 900 20 960 920
132 S 5,5 123 - 1030
50-160 90 L 2,2 P 272 31 80 360 540 320 130 225 800 70 900 820
100 L 3,0 86 50 60 950
112 M 4,0 P 303 114 390 600 350 150 60 900 48 960 920
132 S 5,5 129 28 1030
132 S 7,5 9 133
160 M 11,0 P 344 197 450 30 660 400 170 80 240 1000 - 1200 1020 M 20 x 200
50-200 100 L 3,0 P 272 8 35 92 360 540 320 130 50 65 225 800 60 950 820 M 16 x 160
112 M 4,0 P 303 118 390 600 350 150 60 900 48 960 920
132 S 5,5 133 28 1030
132 S 7,5 9 137
160 M 11,0 P 344 201 450 30 660 400 170 80 240 1000 - 1200 1020 M 20 x 250
160 M 15,0 10 204
50-250 160 M 11,0 9 43 209 75 260 20
160 M 15,0 10 213
160 L 18,5 S 385 273 490 40 740 440 190 110 290 1120 1250 - -
180 M 22,0 12 297 - 1270
200 L 30,0 P 436 383 540 30 840 490 205 80 280 1250 20 1370 1270 G1/2

19
Foundation plan for units with spacer type coupling n = 2900 rpm

base
motor plate coup- weight rag bolt
size size kW Nr. ling pum unit a b2 c e1 e2 e4 f1 h h3 l p1 p2 w* w1 ue x DIN 529
PKA p kg kg
65-125 100 L 3,0 P 303 8 29 95 100 390 25 600 350 150 75 65 225 900 - 60 950 920 G1/2 100 M 16 x 160
112 M 4,0 112 48 965
132 S 5,5 127 28 1030
132 S 7,5 9 131
65-160 132 S 5,5 8 34 132
132 S 7,5 9 139
160 M 11,0 P 344 200 450 30 660 400 170 65 80 240 1000 - 1200 1020 M 20 x 250
160 M 15,0 10 204
65-200 160 M 11,0 9 38 204 260 20
160 L 18,5 S 385 10 269 490 40 740 440 190 75 110 290 1120 1250 - -
180 M 22,0 12 292 - 1280
200 L 30,0 P 436 378 540 30 840 490 205 80 280 1250 20 1380 1270 G1/2
65-250 160 L 18,5 S 386 10 62 402 490 40 440 90 110 310 - 40 1340 - -
180 M 22,0 12 326 20 1385
200 L 30,0 S 487 416 610 940 550 230 100 300 1400 - 1485 M 24 x 400
200 L 37,0 14 430
225 M 45,0 15 512 325 25 1540
80-160 132 S 7,5 P 344 9 39 154 125 450 30 660 400 170 80 260 1000 - 48 1055 1020 G1/2 M 20 x 250
160 M 11,0 205 65 20 1225
160 M 15,0 10 209
160 L 18,5 S 385 269 490 40 740 440 190 75 110 290 1120 1270 - -
180 M 22,0 12 293 - 1305
80-200 160 M 15,0 10 56 263 20 1335
160 L 18,5 S 386 296 840 1250 1380
180 M 22,0 12 320 - 1410
200 L 30,0 S 486 410 610 940 550 230 100 300 1400 20 1510 M 24 x 400
200 L 37,0 14 424
80-250 180 M 22,0 S 486 12 69 324 840 205 90 1250 - 20 1410
200 L 30,0 S 487 424 940 230 1400 - 1510
200 L 37,0 14 437
225 M 45,0 15 519 325 25 1565
250 M 55,0 S 606 650 730 1060 670 270 350 1600 50 1685
100-200 160 L 18,5 S 386 12 65 312 490 840 440 205 110 310 1250 40 1420 140 M 20 x 250
180 M 22,0 322 20 1450
200 L 30,0 S 487 422 610 940 550 230 100 300 1400 - 1550 M 24 x 400
200 L 37,0 14 435
225 M 45,0 15 518 325 25 1605
100-250 200 L 30,0 12 78 435 140 - 25 1565
200 L 37,0 14 448
225 M 45,0 15 531 - 1620
250 M 55,0 S 608 661 730 1060 670 270 350 1600 25 1740
280 S 75,0 17 842 380 55 1820
280 M 90,0 20 892 1825

* motor-type of enclosure IP 54, dimensions dependent on motor make

20
Foundation plan for units with spacer type coupling n = 1450 rpm

minimum lenght
of rag bolt

Dimensions in mm, tolerances (base plate) for cast pieces acc. to DIN 1686/GTB 17,
for welded pieces acc. to DIN 8570 B

base
motor plate coup- weight rag bolt
size size kW Nr. ling pump unit a b2 c e1 e2 e4 f1 h h3 l p2 w* w1 ue x DIN 529
PKA kg kg
32-250 80 b 0,75 P 342 8 40 100 100 450 30 540 400 130 75 80 260 800 100 840 820 G1/2 100 M 20 x 250
90 S 1,1 104 90 870
90 L 1,5 108 895
100 L 2,2 P 383 118 490 600 440 150 900 80 950 920
40-250 90 S 1,1 P 342 8 42 106 100 450 30 540 400 130 75 80 260 800 90 870 820 G1/2 100 M 20 x 250
90 L 1,5 110 985
100 L 2,2 P 383 122 490 600 150 900 80 950 920
100 L 3,0 125
40-315 100 L 2,2 S 385 78 174 125 740 190 110 335 1120 125 1080 - -
100 L 3,0 177
112 M 4,0 9 196 113 1090
132 S 5,5 211 93 1165
50-250 90 L 1,5 P 342 8 43 111 100 450 30 540 400 130 75 80 260 900 90 895 920 G1/2 100 M 20 x 250
100 L 2,2 P 383 123 490 600 440 150 80 950
100 L 3,0 126
112 M 4,0 9 145 68 1000
50-315 112 M 4,0 S 385 80 225 125 40 740 190 110 335 1120 113 1090 - -
132 S 5,5 235 93 1165
132 M 7,5 10 253 1200
65-250 100 L 2,2 P 343 8 62 155 100 540 30 660 490 170 90 80 280 1000 100 1060 1020 G1/2 100 M 20 x 250
100 L 3,0 158
112 M 4,0 9 176 88 1070
132 S 5,5 S 385 221 125 490 40 740 440 190 110 310 1120 68 1140 - -
65-315 132 S 5,5 87 241 335 93 1165
132 M 7,5 10 258 1200
160 M 11,0 S 386 12 310 840 205 1250 65 1330
160 L 15,0 335 1375
80-200 90 L 1,5 P 434 8 56 128 125 540 30 660 490 170 75 80 260 1000 90 1035 1020 G1/2 100 M 20 x 250
100 L 2,2 146 80 1080
100 L 3,0 148
112 M 4,0 9 169 68 1090
132 S 5,5 184 48 1165
80-250 100 L 3,0 8 69 164 90 280 100 1080
112 M 4,0 9 183 88 1090
132 S 5,5 S 385 219 490 40 740 440 190 110 310 1120 68 1165 - -
132 M 7,5 10 235 1200
80-315 132 S 5,5 9 92 245 360 118 1165
132 M 7,5 10 263 1200
160 M 11,0 S 386 12 311 840 205 1250 90 1330
160 L 15,0 335 1375
100-200 100 L 2,2 P 434 8 65 163 125 540 30 660 490 170 90 80 280 1000 100 1125 1020 G1/2 140 M 20 x 250
100 L 3,0 166
112 M 4,0 S 385 9 203 490 40 740 440 190 110 310 1120 88 1135 - -
132 S 5,5 218 68 1210
132 M 7,5 10 238 1245
100-250 112 M 4,0 9 78 220 140 335 113 1150
132 S 5,5 235 93 1220
132 M 7,5 10 253 1260
160 M 11,0 S 386 12 305 840 205 1250 65 1390
100-315 160 M 11,0 97 321 90
160 L 15,0 346 360 1430
180 M 18,5 14 370 70 1460
180 L 22,0 15 395 80 1500
125-250 132 M 7,5 S 385 10 97 273 140 490 40 740 440 190 90 110 360 1120 118 1260 - - 140 M 20 x 250
160 M 11,0 S 386 12 321 840 205 1250 90 1390
160 L 15,0 347 1430

21
Data regarding size - order notes
Series + Hydraulic+ bearing Shaft seal Material design Casing seal
size
A. speed n = 1450 rpm AAE standard mechanical seal 0A standard design cast iron
B. speed n = 2900 rpm O-rings Perbunan 0C as per 0A, but impeller of 2 flat seals
.B two greased AA1 as per AAE, but G-CuSn 10
O-rings Viton 3B main parts of G-CuSn 10
antifriction bearing
32-125 BB
32-160 BB
32-200 BB
32-250 AB
32-250 BB
40-125 BB
40-160 BB
40-200 BB
40-250 AB
40-250 BB
40-315 AB
50-125 BB
50-160 BB
50-200 BB
50-250 AB
50-250 BB alternatively
ULN 50-315 AB alternatively 0A
65-125 BB AAE 0C 2
65-160 BB AA1 3B
65-200 BB
65-250 AB
65-250 BB
65-315 AB
80-160 BB
80-200 AB
80-200 BB
80-250 AB
80-250 BB
80-315 AB
100-200 AB
100-200 BB
100-250 AB
100-250 BB
100-315 AB
125-250 AB

Design Designation Selection table motors

pump with free shaft end 01 motor n = 2900 rpm motor n = 1450 rpm
pump with coupling, ready drilled at motor side kW size designation kW size designation
and coupling guard for the shaft coupling 41 0,55 71 b EA 0,25 71 a DB
as above, but pump and coupling guard for the 0,75 80 a FA 0,37 71 b EB
shaft coupling, mounted on base plate, 1,1 80 b GA 0,55 80 a FB
incl. supports for pump and motor and 1,5 90 S HA 0,75 80 b GB
1 set of rag bolts 53 2,2 90 L JA 1,1 90 S HB
as above, but with motor 3,0 100 L KA 1,5 90 L JB
e.g. 18,5 kW-three-phase AC motor e.g. UA 4,0 112 M MA 2,2 100 L KB
(50 Hz, 380 V) V9 V), rpm
at 2900 5,5 132 S NA 3,0 100 L LB
7,5 132 S OA 4,0 112 M MB
11 160 M SA 5,5 132 S NB
15 160 M TA 7,5 132 M PB
Important: 18,5 160 L UA 11 160 M SB
In case of order please indicate always output 22 180 M VA 15 160 L UB
Q  m³/h  and delivery head H  m . 30 200 L XA 18,5 180 M VB
37 200 L YA 22 180 L WB
45 225 M AA
55 250 M BA
75 280 S CA
90 280 M DA
Example for ordering:
The size ULN 65-250 BB AAE 0A 2 with coupling, pre-drilled at the motor side and coupling guard
for the shaft coupling has the complete order number: ULN . 65-250 BB AAE 0A 2 41
The size ULN 65-250 BB AAE 0A 2 as complete unit with 18,5 kW three-phase AC motor, 2900 rpm
has the complete order number: ULN . 65-250 BB AAE 0A 2 UA
On delivery, the period ( . )at the fourth place of the type designation is replaced by a letter in the factory.
On ordering the designs 41 and 53 please indicate always the provided motor in order that the coupling can be ready drilled at motor side and
choose the correct base plate and to enclose the proper documentation.
On request, the bearing bracket can be delivered in oil-lubricated design against additional costs-please indicate extra.
Any changes in the interest of the technical development are reserved.

22
Sterling SIHI (Spain), S.A.
Vereda de los Zapateros s/n, Pozuelo de Alarcón 28223 Madrid, Spain.
Telephone +34 91 709 1310 Telefax +34 91 715 9700
www.sihi.com

23