DS0124 Standard EU en
DS0124 Standard EU en
DS0124 Standard EU en
www.burkert.com p. 1/4
0124
Technical data
Circuit Max. operating pressure [bar] when using the valve in a new circuit function
function Orifice 3.0 Orifice 4.0
A B C D E F A B C D E F
C 10 1 10 1 1 10 5 0.8 5 0.8 0.8 5
D 6 6 6 6 6 3 3 3 3 3 3 3
F 5 1 6 1 1 10 4 1 4 1 1 4
Materials
Manual override: PA
p. 2/4
0124
connection
frequency
Pressure
Voltage/
Kv value
function
material
material
Item no.
Item no.
Orifice
Circuit
[V/Hz]
EPDM
[m3/h]
range
water
[mm]
FKM
[bar]
Seal
Seal
Port
All valves body material PP, manual override and cable plug, different seal materials
A G 1/4 3.0 0.25 0-8 024/DC 018 410 067 214
0 - 10 24/50 088 496 022 105
230/50 045 653 062 398
G 1/4 4.0 0.30 0-4 024/DC 062 695 021 660
0-5 024/50 043 005 067 731
110/50 087 029 –
230/50 063 116 063 118
G 1/4 5.0 0.40 0-3 024/DC 062 624 061 321
0 - 4.5 024/50 067 007 054 261
110/50 – 088 468
230/50 022 619 049 969
C G 1/4 4.0 0.30 0-5 024/50 088 420 –
230/50 – 063 625
E G 1/4 3.0 0.25 0-4 024/DC 069 917 078 556
0-6 024/50 066 230 –
230/50 022 294 078 559
G 1/4 4.0 0.30 0-2 024/DC 061 077 067 160
0-3 024/50 086 921 044 693
230/50 053 406 066 033
F G 1/4 4.0 0.30 0-4 024/DC 020 528 –
0-5 230/50 – 066 032
All valves with body material PVDF, manual override and cable plug, seal material FKM
A G 1/4 3.0 0.25 0-8 024/DC 018 188 –
0 - 10 024/50 020 286 –
110/50 078 784 –
230/50 069 006 –
G 1/4 4.0 0.30 0-4 024/DC 023 472 –
0-5 024/50 069 079 –
230/50 087 837 –
G 1/4 5.0 0.40 0-3 024/DC 064 512 –
0 - 4.5 230/50 063 786 –
C G 1/4 4.0 0.30 0-4 024/DC 055 788 –
0-5 230/50 019 078 –
E G 1/4 4.0 0.30 0-2 024/DC 022 340 –
0-3 024/50 020 550 –
230/50 085 599 –
A 2/2-way valve NC C 3/2-way valve NC E 3/2-way mixer valve F 3/2-way distribution valve
A
P1 P2
I &URTHERôVERSIONSôONôREQUEST
Approvals
UR, CSA, ATEX
Voltage
Non-standard voltages
Pressure
BAR Vacuum version
Port Connection
NPT 1/4, sub-base
Materials
Seal material - FFKM
Additional
Optical or electrical feedback
p. 3/4
0124
Dimensions [mm]
The ports are marked with 1, 2 and 3 as indicated in the configuration table,
depending on the circuit function.
Circuit function 1 2 3
A1) A - P
C P A R
E P1 A P2
F A P B
1)
Type 0124 has no middle connection in circuit function A.
To find your nearest Bürkert facility, click on the orange box www.burkert.com
p. 4/4