2/2 or 3/2-Way Solenoid Valve, With Pivoted Armature and Isolating Diaphragm
2/2 or 3/2-Way Solenoid Valve, With Pivoted Armature and Isolating Diaphragm
2/2 or 3/2-Way Solenoid Valve, With Pivoted Armature and Isolating Diaphragm
www.burkert.com p. 1/5
0330
Materials
Coil: Epoxy
p. 2/5
0330
Kv value
threaded port
2)
Item no. per voltage/frequency [V/Hz]
Orifice [mm]
connection
water [m3/h] 1), 4)
range [bar]
Pressure
function
material
024/DC
024/50
230/50
Circuit
Seal
Port
DC
AC
A 2/2-way valve NC 3) Brass body
ô! G 1/4 3.0 0.14 0.18 0-10 FKM 020 293 022 883 124 909
NBR 020 294 086 553 024 902
ô0 4.0 0.17 0.23 0-5 FKM 024 019 025 246 124 912
NBR 025 084 – 046 007
Stainless steel body
G 1/4 3.0 0.14 0.18 0-10 FKM 020 292 023 984 024 563
4.0 0.17 0.23 0-5 018 276 018 857 020 873
B 2/2-way valve NO 3) Brass body
ô! G 1/4 3.0 0.14 0.18 0-10 FKM 141 917 130 146 141 919
4.0 0.17 0.23 0-5 141 920 141 921 141 923
ô0 Stainless steel body
G 1/4 3.0 0.14 0.18 0-10 FKM 141 928 141 929 141 931
4.0 0.17 0.23 0–5 141 932 141 933 141 935
C 3/2-way valve NC Brass body
ô! G 1/4 2.0 0.08 0.11 0-16 NBR 041 103 042 129 041 105
3.0 0.14 0.18 0-10 041 107 041 108 041 116
0 ô2 4.0 0.17 0.23 0-5 042 218 042 695 042 329
Stainless steel body
G 1/4 3.0 0.14 0.18 0-10 FKM 052 344 045 024 052 059
4.0 0.17 0.23 0-5 050 483 043 324 050 979
D 3/2-way valve NO Brass body
ô" G 1/4 2.0 0.08 0.11 0-16 NBR 056 984 041 858 041 137
3.0 0.14 0.18 0-10 041 139 041 141 041 147
0 ô2
4.0 0.17 0.23 0-5 043 129 042 696 042 903
T 3/2-way valve, Brass body
universal function, G 1/4 2.0 0.08 0.11 0-12 FKM 124 922 138 316 124 925
any flow direction
3.0 0.14 0.18 0-8 124 927 124 928 124 930
Stainless steel body
G 1/4 2.0 0.08 0.11 0-12 FKM 124 932 124 933 124 935
3.0 0.14 0.18 0-8 124 937 124 938 124 940
Vacuum version
C 3/2-way valve NC Brass body
G 1/4 3.0 0.14 0.18 Vac. -6 NBR 043 894 046 815 –
4.0 0.17 0.23 Vac. -3 044 302 – 042 879
1)
Measured at +20 °C, 1 bar2) pressure at valve inlet and free outlet. 2) Pressure data [bar]: Overpressure with respect to atmospheric pressure
3)
The listed Item no. and circuit functions have a valve body with a straight through channel (var. code AF02)
4)
In DC-versions with orifice 3.0 and 4.0 the orifice diameter is reduced by about 0,5mm.
I &URTHERôVERSIONSôONôREQUEST
Approvals Circuit function
Explosion protection (Type 780), ATEX, UL, UR, FM - Ex Div. 1 E (mixing) or F (distributing)
Voltage Port connection
Non-standard voltages NPT, G 1/8
Materials Additional
Seal materials EPDM, FFKM Impulse version, optical or electrical position feedback (type 1060),
further device combinations
p. 3/5
0330
Ordering chart for valves, analysis and vacuum version (other versions on request)
Stainless steel body, seal material FKM or NBR, manual override and without cable plug (see Accessories)
Kv value water Pressure Item no. per voltage/frequency
[m3/h] 1) 4) range [bar]2) [V/Hz]
Circuit function
threaded port
Seal material
Orifice [mm]
connection
024/DC
024/50
230/50
(DC)
Port
DC
AC
Analysis version
A 2/2-way valve NC3) Stainless steel body
! G 1/4 2.0 0.08 0.11 Vac. -10 FKM 137 839 – 137 842
3.0 0.14 0.18 Vac. -6 137 843 – 137 846
0 4.0 0.17 0.23 Vac. -3 122 101 – 137 849
T 3/2-way valve, universal Stainless steel body
function, any flow direction G 1/4 2.0 0.08 0.11 Vac. -8 FKM 137 850 – 137 854
3.0 0.14 0.18 Vac. -5 FKM 137 855 – 137 858
4.0 0.17 0.23 Vac. -3 FKM 137 859 – 137 862
1)
Measured at +20 °C, 1 bar2) pressure at valve inlet and free outlet. 2)
Pressure data [bar]: Overpressure with respect to atmospheric pressure
3) 4)
The listed item nos. have a valve body with straight through channel In DC-versions with orifice 3.0 and 4.0 the orifice diameter is reduced by about 0.5mm.
Please note that the cable plug has to be ordered separately, see Accessories on next page and separate datasheet for Type 2508.
p. 4/5
0330
Fixing screw
frequency
Voltage /
Circuitry
Item no.
Flat seal
Dimensions [mm]
'ô
'ô
'ô
To find your nearest Bürkert facility, click on the orange box g www.burkert.com
p. 5/5