Examples Calcn On Infiltration
Examples Calcn On Infiltration
Examples Calcn On Infiltration
Problem:
Estimate the preliminary size of an infiltration trench proposed for the USM School of Civil Engineering
building in Nibong Tebal, Pulau Pinang with 1.59ha of institutional area. The impervious area is 65% of the
catchment area. Given the value of infiltration rate, f = 35 mm/hr, maximum storage time, Ts = 24 hr, effective
filling time, Tf = 2 hr and porosity of fill materials, n = 0.35.
a) Site Plan
152m
122m
72m
37m
Perimeter Drain
Roof
Grass
Proposed Infiltration
Trench
Solution:
Table 2.5 Runoff coefficient for commercial and business centres = 0.95
Runoff coefficient for sport fields, park and agriculture = 0.40
Impervious area = 0.65
Pervious area = 0.35
f c Ts
Maximum allowable depth, d max
Equation 8.1 n
0.035 24
0.35 = 2.4m
A
PLAN Pretreatment
BMPs
Concrete Level
Spreader
25m
Overflow Berm
Outflow to Main
Drainage System
50m
SECTION A-A
Trench Filled
Protective Layer of With Clean Stone
Filter Fabric
Problem:
Estimate the preliminary size of an infiltration basin proposed for the Bertam Perdana, Pulau Pinang. The
catchment area is 12.70ha with 52% of impervious area. The site condition of pre-development is palm oil
plantations. From initial site investigation, the characteristic of the catchment is as follows:
400m
Inlet
Outfall Inlet
300m
Table 2.5 Runoff coefficient for commercial and business centres = 0.95
Runoff coefficient for sport fields, park and agriculture = 0.40
Impervious area = 0.52
Pervious area = 0.48
Equation Lb = Lt - 2Zdb
8.10a
Equation Wb = Wt -2Zdb
8.10b
Equation Lt = [ Vw + Zdb (Wt -2Zdb)] / [ Wt db Zdb2]
8.11
Vw is equal to WQV and Say Wt is 100m
Wb = 75.04(2x4x0.5) = 71.04m
Lb = 100-(2x4x0.5) = 96m
PLAN
Inlet
A
96.0m 100.0m
Riprap Outfall
Protection
Outlet
Inlet
71.0m
75.0m
SECTION A-A
100.0m Inflow
Pretreatment
Excess Runoff Water Quality Volume
(WQv)
Grass Turf
0.2m
4
0.5m 1
Clean Stone
96.0m