SPECIFICATIONS MANUAL

AIR CONDITIONER (CASSETTE TYPE)


Cooling Model

Indoor Unit / Outdoor Unit


AUGA18FRTA-M / AOGA18FBTBHM
AUGA25FRTA-M / AOGA25FBTBHM
AUGA30FRTA-M / AOGA30FBTCSM
AUGA36FRTA-M / AOGA36FRTCSM
SPECIFICATIONS
TYPE CASSETTE (COOLING MODEL)

INDOOR UNIT AUGA18FRTA-M AUGA25FRTA-M AUGA30FRTA-M AUGA36FRTA-M


MODEL OUTDOOR UNIT AOGA18FBTBHM AOGA25FBTBHM AOGA30FBTCSM AOGA36FRTCSM
CASSETTE GRILLE UTG-UKGB-W
POWER SOURCE 220 - 240V ~ 50Hz 3N ~ 380 - 415V 50Hz
COOLING (T1) at 230V at 400V
[BTU/h] 19,100 22,800 28,900 35,800
CAPACITY
[kW] 5.60 6.68 8.47 10.50
INPUT POWER [kW] 1.48 1.85 2.33 2.99
CURRENT [A] 6.5 8.3 11.0 5.0
EER [BTU/h•W] 12.91 12.32 12.40 11.97
ANNUAL ENERGY CONSUMPTION [kWh] 3,996 4,995 6,291 8,073
COOLING (T3) at 230V at 400V
[BTU/h] 17,000 19,700 25,500 31,400
CAPACITY
[kW] 4.98 5.77 7.47 9.20
INPUT POWER [kW] 1.77 2.2 2.92 3.73
CURRENT [A] 7.8 9.9 13.2 6.0
EER [BTU/h•W] 9.60 8.95 8.73 8.42
SUCTION [MPa] 1.2 1.2
MAX. PRESSURE
DISCHARGE [MPa] 4.2 4.4
MAX. CURRENT [A] 13.5 16.5 23.0 10.5
REFRIGERANT (R410A) [kg] 1.5 1.8 2.5 3.4
DIMENSIONS & WEIGHT (NET)
HEIGHT [mm] 246 288
WIDTH [mm] 840 840
INDOOR UNIT
DEPTH [mm] 840 840
WEIGHT [kg] 24 26.5 29.0
HEIGHT [mm] 650 830 914 1,290
WIDTH [mm] 830 900 970 900
OUTDOOR UNIT
DEPTH [mm] 320 330 370 330
WEIGHT [kg] 50 63 77 100
HEIGHT [mm] 53
WIDTH [mm] 950
CASSETTE GRILLE
DEPTH [mm] 950
WEIGHT [kg] 6
TEMPERATURE RANGE (OUTDOOR) [°C] 21 to 52
TEMPERATURE RANGE (INDOOR) [°C] 18 to 32
HUMIDITY RANGE (INDOOR) [%] 80 or less

● Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor unit.
According to IEC 704-1 and ISO 3744.
● CONDITION
COOLING(T1) : INDOOR 27/19 °C (DB/WB) OUTDOOR 35/24 °C (DB/WB)
COOLING(T3) : INDOOR 29/19 °C (DB/WB) OUTDOOR 46/24 °C (DB/WB)
● If the air conditioner is operated under higher temperature conditions than those listed, the built-in protection circuit may operate to prevent internal circuit
damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperatures than those listed above, the heat-exchanger
may freeze, leading to water leakage and other damage.
● If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip onto the floor or
other objects underneath.
● Refer to the rating label with the serial number.

KEEP THIS MANUAL FOR FUTURE REFERENCE


MADE IN THAILAND
PART No. 9387351194