Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

4R3CD 2306 en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

4R35 / 4R36 2306

4R35 / 4R36
DIVER’S WATCH FOR AIR DIVING INSTRUCTIONS

日本語 .................................................. JA 1
English ................................................ EN 1

そのほかの言語の取扱説明書は、パソコンや Please refer to the Instruction Manuals


スマートフォンから当社ホームページ内の of other languages by accessing
「カスタマーサービス」>「取扱説明書」 "Customer Service"→ "Instruction"
にアクセスいただき、ご覧ください。 on our Website from PC or Smartphone.

Deutsch / Français / Italiano / Español /


Pусский язык / / Português /
䬁Ổᶮ㔈 / ䷂橕ᶮ㔈 / 㭛๸⧄ /

https://www.seikowatches.com/
Thank you very much for choosing a SEIKO watch. b WARNING
Make sure to read the following instructions before use and strictly observe them.
For proper and safe use of your SEIKO watch,
please read carefully the instructions in this b WARNING
When diving, never carry out operations other than those specified in this instruction manual. Mishandling
booklet before using it. of the product and misunderstanding of the displayed content may lead to a fatal or serious accident.

b WARNING
Keep this manual handy for easy reference. The diver’s watch is an auxiliary instrument which mainly displays the passage of time and does not ensure
the safety of a user. Use this watch while using the equipment (residual pressure gauge, water depth meter,
* Length adjustment service for metallic bands is available at the retailer from etc.) required for safe diving.
whom the watch was purchased. If you cannot have your watch repaired by b WARNING
the retailer from whom the watch was purchased because you received the Never use this watch for “saturation diving” using helium gas.
watch as a gift, or you moved to a distant place, please contact SEIKO
b WARNING
CUSTOMER SERVICE CENTER. The service may also be available on a
Do not dive using this product unless you have been properly trained in scuba diving, acquired the requisite
chargeable basis at other retailers, however, some retailers may not undertake experience and techniques for safe diving, thoroughly familiarized yourself with the operation and handling
the service. of this product, and inspect all functions of this product prior to each dive.

* If your watch has a protective film for preventing scratches, make sure to peel
it off before using the watch. If the watch is used with the film on it, dirt, sweat,
dust, or moisture may be attached to the film and may cause rust.

EN 1 EN 2

b CAUTION CONTENTS
Make sure to read the following instructions before use and strictly observe them.
1 HOW TO USE How to use the rotating bezel ........................ 29
b CAUTION
Handling cautions ............................................ 5
Inspect the following items before diving (excluding saturation diving): 2 TO PRESERVE THE QUALITY OF YOUR
• The watch is operating normally. Precautions for diving (Please make sure to WATCH
• The remaining battery level is sufficient and the mainspring is sufficiently wound. observe the following) ..................................... 9
Daily care ...................................................... 31
• The rotating bezel turns smoothly. (The bezel rotation must not be too loose or too tight.) Before diving ................................................ 9
Performance and type ................................... 32
• Screws of the crown and other parts are reliably tightened. While diving ............................................... 11
• No abnormalities such as flaws or cracks exist on the band or glass. Lumibrite ....................................................... 33
• The band is reliably fixed (with spring bar, buckle or other parts.) After diving ................................................. 12
Magnetic resistant performance .................... 34
* If any abnormality is observed in the above items, do not use this watch for diving. Structure of the case .................................. 13
Band .............................................................. 36
b CAUTION Mechanical watch characteristics
How to use the diver adjuster ........................ 38
(Hand-wound, auto-wound) ........................... 14
Do not operate the crown or buttons underwater. How to use the diver extender ....................... 40
Names of the parts and their functions .......... 15
b CAUTION After sales service ......................................... 42
Screw down crown ........................................ 17
As the use environment of the diver’s watch may affect not only the case or band but also the internal Accuracy of mechanical watches .................. 44
How to wind the mainspring .......................... 18
mechanism of the watch, we recommend that you periodically request an overhaul for inspection and Troubleshooting ............................................ 46
adjustment approximately once every two to three years. How to set the time and date (4R35) ............. 20
Specifications ................................................ 48
Date adjustment at the end of the month ... 23
How to set the time, date, and day of the week
(4R36) ........................................................... 24
Date adjustment at the end of the month ... 28
EN 3 EN 4
1 Handling cautions b CAUTION 1
Please note that there is a risk of minor injury or material damage if the following safety
HOW TO USE

HOW TO USE
regulations are not strictly observed.
b WARNING
Avoid the following places for wearing or keeping the watch:
Please note that there is a risk of serious consequences such as severe injury if the following
○ Places where volatile agents (cosmetics such as polish remover, bug repellent, thinners etc.) are
safety regulations are not strictly observed. vaporizing
○ Places where the temperature drops below ○ Places affected by strong vibrations
Immediately stop wearing the watch in following cases: 5°C or rises above 35°C for a long time ○ Places of high humidity
○ If the watch body or band becomes edged by corrosion etc. ○ Places affected by strong magnetism or static ○ Dusty places
○ If the pins protrude from the band. electricity
* Immediately consult the retailer from whom the watch was purchased or SEIKO CUSTOMER SERVICE
CENTER. If you observe any allergic symptoms or skin irritation
Stop wearing the watch immediately and consult a specialist such as a dermatologist or an allergist.
Keep the watch and accessories out of the reach of babies and children.
Other cautions
Care should be taken to prevent a baby or a child accidentally swallowing the accessories.
○ For adjusting the length of the metallic band, specialized knowledge and expertise are necessary.
If a baby or child swallows the battery or accessories, immediately consult a doctor, as it will be Therefore, in such a case, contact the retailer from whom the watch was purchased. If you attempt
harmful to the health of the baby or child. to adjust the metallic band, injury may occur to your hand or fingers, or parts of the band may be
lost.
○ Do not disassemble or tamper with the watch.
○ Please follow local government directions when disposing of the watch body.
○ Keep the watch out of the reach of babies and children. Extra care should be taken to avoid risks
of any injury or allergic rash or itching that may be caused when you touch the watch.
○ If your watch is of the fob or pendant type, the strap or chain attached to the watch may damage
your clothes, or injure the hand, neck, or other parts of your body.

EN 5 EN 6

1 b WARNING b CAUTION 1
Please note that there is a risk of minor injury or material damage if the following safety
HOW TO USE

HOW TO USE
Never use the watch, in saturation diving using helium gas. regulations are not strictly observed.

Do not turn or pull out the crown when the watch is wet.
Water may get inside of the watch.
b WARNING * If the inner surface of the glass is clouded with condensation or water droplets appear
inside of the watch for a long time, the water resistant performance of the watch is
While diving, never operate the watch in any other manner than set forth in the instruction deteriorated. Immediately consult the retailer from whom the watch was purchased or
manual. SEIKO CUSTOMER SERVICE CENTER.

Do not leave moisture, sweat and dirt on the watch for a long time.
Be aware of a risk that a water resistant watch may lessen its water resistant
b WARNING performance because of deterioration of the adhesive on the glass or gasket, or
the development of rust on stainless steel.
Before using the diver’s watch, you have to be properly trained in various types of diving and
possess the requisite experience and skill to dive safely. When diving, strictly abide by the
rules of diving.
Do not wear the watch while taking a bath or a sauna.
Steam, soap or some components of a hot spring may accelerate the
deterioration of water resistant performance of the watch.

EN 7 EN 8
1 Precautions for diving (Please make sure to observe the following) 1
4 The crown is completely
screwed in.
HOW TO USE

HOW TO USE
■ Before diving * “Screw down crown” → P.17
Before diving, check the following:
* “Names of the parts and their functions” → P.15 5 There are no visible cracks or
scratches on the crystal or
watch band.
1 The time is correctly set.
1 6 The band is firmly attached to
4
2 watch so that it does not stop in
Turn the crown to wind up the the watch (with spring bars,
clamp or other parts.)
the water.
* “Screw down crown” → P.17
5 6
* “How to wind the mainspring” → P.18

3 The rotating bezel turns


smoothly.
b CAUTION
(The bezel rotation must not be
too loose or too tight.)
* “How to use the rotating bezel” → P.29
2 If there are any malfunctions, contact the retailer from whom the watch was purchased
or SEIKO CUSTOMER SERVICE CENTER.
3

EN 9 EN 10

1 ■ While diving ■ After diving 1


Please observe the following cautions for use. Please follow the care instructions below after diving.
HOW TO USE

HOW TO USE
The watch can be used for air diving within the water Do not operate the crown or buttons underwater. Rinse the watch in fresh water to wash out all seawater and wipe it thoroughly dry to prevent rust.
resistant range displayed on the dial. Avoid pouring running water onto the watch directly from a faucet. Put some water into a bowl first, and
then soak the watch in the water to wash it.

b CAUTION
Depending on the environment where a diver’s watch is used, its inner parts or movement
as well as its case or band may be affected. We recommend that you have your watch
Take care not to bump the watch against hard Bezel rotation may become slightly harder in the overhauled regularly once every 2 or 3 years.
objects such as rocks. water but this is not a malfunction.

EN 11 EN 12
1 ■ Structure of the case Mechanical watch characteristics (Hand-wound, auto-wound) 1
In the following types of models, take care of the following issues in usage.
HOW TO USE

HOW TO USE
The bezel or protective outer case is securely fastened to the watch with setscrews. • This is a mechanical watch powered by a spring.
Never loosen the setscrews. • To use it from a stopped state, turn the crown 20 turns by hand to wind up the spring before starting the
setscrew setscrew watch.
• Although the accuracy of quartz watches is measured in differences over months or years, in mechanical
watches it is measured in differences per day (i.e., the amount the watch speeds up or slows down in a
single day).
• Additionally, mechanical watches are subtly affected by the conditions in which they are used (e.g.,
duration worn, temperature, arm movement, the amount wound, etc.) ; thus, the amount of error is not
constant.
• When affected by a strong magnetism from outside, the mechanical watch may lose/gain time. The parts
of the watch may become magnetized depending on the extent of the effect. In such a case, consult the
retailer from whom the watch was purchased since the watch requires repair including demagnetizing.
* The above illustration is provided as an example, therefore it may not be exactly the same as your watch.

b CAUTION
Never loosen the setscrews used to fix the bezel or protective outer case.
Doing so may cause damage or result in further loosening.
* If you find that the setscrews have become loose or are functioning abnormally, consult the retailer from whom
the watch was purchased or SEIKO CUSTOMER SERVICE CENTER.

EN 13 EN 14

■ 4R36
1 Names of the parts and their functions 1
1 1 Minute hand
HOW TO USE

HOW TO USE
■ 4R35 2 Hour hand
1 Minute hand 2 3 Seconds hand
1 4
2 Hour hand 4 Date and day of the week

2 3 Seconds hand 5 Rotating bezel


4 3 5 6 Crown
4 Date MON
• Normal position (not locked):
5 Rotating bezel 6 Wind up the watch (hand-wound)
3 5 6 Crown • First click position: Date and day
• Normal position (not locked): of the week setting
Wind up the watch (hand-wound) • Second click position: Time
6 setting
• First click position: Date setting
• Second click position: Time
setting

* The position and design of the display may vary depending on the model.

* The position and design of the display may vary depending on the model.

EN 15 EN 16
1
HOW TO USE
Screw down crown How to wind the mainspring 1

HOW TO USE
The screw down crown features a mechanism that can securely lock the crown when it is not • This is an automatic mechanical watch with a manual winding mechanism.
being operated in order to prevent any operational errors and to improve its water resistant
performance. • When the watch is worn on the wrist, the mainspring is wound automatically through normal wrist
• It is necessary to unlock the screw down crown before operating it. movement. The watch can also be wound up by turning the crown.
• Once you have finished operating the crown, make sure to relock it.
• To start the watch after it stops completely, wind it up either by turning the crown or swinging it from side
[To unlock the crown] [To lock the crown] to side until the seconds hand starts moving. Then, set the time and date before putting the watch on
Turn the crown counterclockwise to unscrew it. Turn the crown clockwise while gently pressing it in the wrist. To wind up the watch, turn the crown clockwise slowly. The watch cannot be wound by turning
Now the crown can be operated. toward the watch body until it stops. the crown counterclockwise. In this way, the watch can be wound up fully. Furthermore, turning the crown
further will not break the spring.
Crown locked Crown unlocked * For the watch with screw down crown, please unlock the crown before operating it and be sure to lock the crown
Unlock the crown before After operating the crown,
operating it. lock it. after operating it.

• Once the watch is wound up fully, it operates for about 41 hours.

Rotate while
Unscrew pressing
the crown in.

* When locking the crown, turn it slowly with care, ensuring that the screw is properly engaged. Be careful not to
push it in forcefully, as doing so may damage the screw hole in the case.

EN 17 EN 18

How to set the time and date (4R35)


* If the watch is used without being wound up fully, gain or loss of time may result. To avoid this, wear the watch for
1 more than 10 hours a day. If the watch is used without being worn on the wrist, be sure to wind it up fully every day 1
at a fixed time.
HOW TO USE

HOW TO USE
The watch is provided with a date function and is so designed that the date changes once every
* If you use a watch that has stopped with the mainspring unwound, winding the mainspring with the crown will not
24 hours.
start the watch immediately. That is because the mainspring torque or force is low at the beginning of its winding
due to the characteristics of mechanical watches. The seconds hand will start to move when a certain degree of The date changes around 12 o’clock midnight. If AM/PM is not properly set, the date will change
torque is reached after the mainspring has been wound up. However, swinging the watch from side to side to at 12 o’clock noon.
forcibly turn the balance can start the watch sooner. * To adjust the date only on a day such as the next day after the completion of a month that has less than 31 days
(February, April, June, September and November), please refer to “Date adjustment at the end of the month”
→ P.23.

b CAUTION
Do not set the date between 9:00 p.m. and 1:00 a.m.
Amending the date during this time period may cause problems such as the date failing
to change the next day.

EN 19 EN 20
1 1 Make sure that the watch is working.
* To carry out the procedure, please make sure that the watch is in working state. Please wind the mainspring 5 Pull out the crown to the second click and set 1
when the watch is not working. the time.
HOW TO USE

HOW TO USE
Pull out the crown to the second click when the seconds

2 Unlock the crown. hand is at the 12 o’clock position; the seconds hand stops
on the spot.
* “Screw down crown” → P.17 Turn the crown to advance the hands until the date
changes to the next. The time is now set for the A.M. period.

3 Pull out the crown to the first


click.
Advance the hands to set the correct time.
* To set the time correctly, be sure to turn back the minute hand
a little behind the desired time and then advance it to the exact
Pull out the crown to the time.
first click
6 Push the crown back in to the normal position in accordance with a time signal.
The seconds hand immediately starts moving.

4 The date can be set by turning the crown. * The telephone time signal service is helpful for setting the seconds hand exactly.

Turn it until the previous day’s date appears.


Ex.) To display the date as “6,” then set this to “5.”
Turn the crown counterclockwise to set the date.
7 Relock the crown.
* “Screw down crown” → P.17

EN 21 EN 22

1 ■ Date adjustment at the end of the month How to set the time, date, and day of the week (4R36) 1
It is necessary to adjust the date at the end of February and 30-day months.
HOW TO USE

HOW TO USE
The watch is provided with a date and day of the week function and is so designed that the date
Ex.) To adjust the date in the A.M. period on the first day of a month following a 30-day month and day of the week change once every 24 hours.
The watch displays “31” instead of “1.” Pull out the crown to the first click. The date changes around midnight, and the day of the week changes at around 4:00 a.m. If
Turn the crown counterclockwise to set the date to “1” and then push the crown back in to the normal AM/PM is not properly set, the date will change at 12 o’clock noon, and the day of the week will
position. change at around 4:00 p.m.
* To adjust the date only on a day such as the next day after the completion of a month that has less than 31 days
(February, April, June, September and November), please refer to “Date adjustment at the end of the month”
→ P.28.
Pull out the crown to the
first click
b CAUTION
Do not set the date or the day of the week between 9:00 p.m. and 4:00 a.m.
b CAUTION Amending the date or the day of the week during this time period may cause problems
• Return the screw down crown fully to its original position. such as the date or the day of the week failing to change the next day or may cause
• Avoid amending the date when the watch is displaying between 9 PM and 1 AM. Doing damage.
so may cause damage.

EN 23 EN 24
1 1 Make sure that the watch is working.
* To carry out the procedure, please make sure that the watch is in working state. Please wind the mainspring
4 The date and day of the week can be set by turning the crown.
Turn it until the previous day’s date/day of the week appears. 1
when the watch is not working. Ex.) To display the date as “6,” then set this to “5.”
HOW TO USE

HOW TO USE
2 Unlock the crown.
* “Screw down crown” → P.17
Turn the crown counterclockwise to set
the date, and turn the crown clockwise to
MON
Set the day of the week
set the day of the week.
For models with bilingual day of the week
3 Pull out the crown to the first
click.
displays, choose the language of your
preference when setting the day of the
Set the date
Pull out the crown to the week.
first click

EN 25 EN 26

■ Date adjustment at the end of the month


1 5 Pull out the crown to the second click and set
the time. It is necessary to adjust the date at the end of February and 30-day months.
1
HOW TO USE

HOW TO USE
Pull out the crown to the second click when the seconds
hand is at the 12 o’clock position; the seconds hand stops Ex.) To adjust the date in the A.M. period on the first day of a month following a 30-day month
on the spot. The watch displays “31” instead of “1.” Pull out the crown to the first click.
Turn the crown to advance the hands until the date Turn the crown counterclockwise to set the date to “1” and then push the crown back in to the normal
changes to the next. The time is now set for the A.M. period. position.
Advance the hands to set the correct time.
* To set the time correctly, be sure to turn back the minute hand
a little behind the desired time and then advance it to the exact
time. Pull out the crown to the
first click
6 Push the crown back in to the normal position in accordance with a time signal.
The seconds hand immediately starts moving.
* The telephone time signal service is helpful for setting the seconds hand exactly.
b CAUTION
7 Relock the crown.
* “Screw down crown” → P.17
• Return the screw down crown fully to its original position.
• Avoid amending the date when the watch is displaying between 9 PM and 4 AM. Doing
so may cause damage.

EN 27 EN 28
How to use the rotating bezel
[One-Way rotating bezel]
1 As the evaluation of the remaining air in your cylinder is based on the information of the elapsed time of the dive, 1
the rotating bezel for a diver’s watch is designed to rotate only counterclockwise, so that the watch is prevented
HOW TO USE

HOW TO USE
By setting the rotating bezel beforehand, the elapsed time since the start of an event can be measured. from displaying the elapsed time shorter than it actually is.

1 you
At the start of the event, for which Example: When you start diving at 10:10 am.
want to measure the elapsed b CAUTION
time (for example, when you start
Align the mark Make sure that you check the correct remaining amount of air in your cylinder before diving.
diving), rotate the bezel so that
with the minute hand Use the display of the elapsed time by the rotating bezel only as a guide during diving.
the mark on the bezel is
aligned with the minute hand. Rotating direction of
* The rotating bezel is designed to rotate only
counterclockwise. the bezel
Do not forcibly rotate it clockwise.
“[One-Way rotating bezel]” → P.30
Example: After 20 minutes has elapsed
2 Read the graduation on the
rotating bezel to which the
minute hand is pointing.
The graduation on the rotating bezel to
which the minute hand is pointing indicates
the elapsed time. Elapsed time

* The above illustration is provided as an example, therefore it may not be exactly the same as your watch.

EN 29 EN 30

Daily care Performance and type


The case back shows the caliber and performance of your watch
2 ● The watch requires good daily care 2
• Do not wash the watch when its crown is in the extended position.
TO PRESERVE THE QUALITY OF YOUR WATCH

TO PRESERVE THE QUALITY OF YOUR WATCH


• Wipe away moisture, sweat or dirt with a soft cloth. Water resistant performance
• After soaking the watch in seawater, be sure to wash the watch in clean pure water and wipe it dry
carefully.
Do not pour running water directly from a faucet onto the watch. Put some water into a bowl first, and
then soak the watch in the water to wash it.

4R35
* If your watch is rated as “Non-water resistant” or “water resistant for everyday life,” do not wash the watch. Case Number
Magnetic resistant

-00
“Performance and type” → P.32
performance

00
● Turn the crown from time to time
• In order to prevent corrosion of the crown, turn the crown from time to time.
• The same practice should be applied to a screw down crown. • Water resistant performance • Magnetic resistant performance
“Screw down crown” → P.17 • Case Number Please refer to P.34 and P.35.
The number to identify the type of your watch.

* The above illustration is provided as an example, therefore it may not be exactly the same as your watch.

EN 31 EN 32
Lumibrite Magnetic resistant performance
If your watch has Lumibrite Affected by nearby magnetism,
2 Lumibrite is a luminous paint that absorbs the light energy of sunlight and lighting apparatuses in a short a watch may temporarily gain or lose time or stop operating.
2
time and stores it to emit light in the dark. For example, if exposed to a light of more than 500 lux for
TO PRESERVE THE QUALITY OF YOUR WATCH

TO PRESERVE THE QUALITY OF YOUR WATCH


approximately 10 minutes, Lumibrite can emit light for 3 to 5 hours. Please note, however, that, as Lumibrite Diver’s watches feature magnetic resistant performance which is equivalent to or above JIS Class 1.
emits the light it stores, the luminance level of the light decreases gradually over time. The duration of the b DANGER
emitted light may also differ slightly depending on such factors as the brightness of the place where the Indication on the case back Condition of use
watch is exposed to light and the distance from the light source to the watch.
Keep the watch more than 5 cm away from magnetic products.
* In general, when coming from a place that is bright to a place that is dark, it takes human eyes some time to adapt No indication
to the darkness making it difficult to see objects initially. (Dark adaptation)
(JIS level-1 standard)
* Lumibrite is luminous paint that stores and emits light, which is harmless to human beings and the environment, Keep the watch more than 1 cm away from magnetic products.
containing no toxic materials such as radioactive substances.
(JIS level-2 standard)
<Brightness levels>
Condition Illumination If the watch becomes magnetized and its accuracy deteriorates to an extent exceeding the specified rate
Fine weather 100,000 lux under normal use, the watch needs to be demagnetized. In this case, you will be charged for
Sunlight
Cloudy weather 10,000 lux demagnetization and accuracy readjustment even if it happens within the guarantee period.
Fine weather More than 3,000 lux
Indoor (Window-side during The reason why a watch is affected by magnetism
Cloudy weather 1,000 to 3,000 lux
daytime) The built-in balance spring may be influenced by a strong external magnetic field.
Rainy weather Less than 1,000 lux
Distance to the watch: 1 m 1,000 lux
Lighting apparatus (40-watt daylight
Distance to the watch: 3 m 500 lux (Average room luminance)
fluorescent light)
Distance to the watch: 4 m 250 lux

EN 33 EN 34

Examples of common magnetic products that may affect watches Band


The band touches the skin directly and becomes dirty with sweat or dust. Therefore, lack of care
2 may accelerate deterioration of the band or cause skin irritation or stain on the sleeve edge. 2
The watch requires a lot of attention for long usage.
TO PRESERVE THE QUALITY OF YOUR WATCH

TO PRESERVE THE QUALITY OF YOUR WATCH


● Metallic band
• Moisture, sweat or soil will cause rust even on a stainless steel band if they are left for a long time.
• Lack of care may result in a rash or cause a yellowish or gold stain on the lower sleeve edge of shirts.
Smartphone, cellular phone, tablet terminal AC adapter Bag • Wipe off moisture, sweat or soil with a soft cloth as soon as possible.
(Speaker, magnet of cover) (With magnet • To clean the soil around the joint gaps of the band, wipe it out in water and then brush it off with a soft
buckle) toothbrush.
(Protect the watch body from water splashes by wrapping it up in plastic wrap etc.)
Clean it off with a soft cloth.
• Because some titan bands use pins made of stainless steel, which has outstanding strength, rust may
form in the stainless steel parts.
• If rust advances, pins may poke out or drop out, and the watch case may fall off the band, or the clasp
may not open.
• If a pin is poking out, personal injury may result. In such a case, refrain from using the watch and request
repair.

AC-powered Magnetic Portable radio Magnetic Magnetic health


shaver cooking device (Speaker) necklace pillow

EN 35 EN 36
● Polyurethane band
• A polyurethane band is susceptible to discoloration from light, and may be deteriorated by solvent or
How to use the diver adjuster
atmospheric humidity.
If your watch’s metallic band has the Diver Adjuster function, the length of the band can be easily
2 • Especially a translucent, white, or pale colored band easily adsorbs other colors, resulting in color smears
or discoloration. adjusted. 2
• Wash out dirt in water and clean it off with a dry cloth. It is very useful when you wear the watch over a wet suit or winter clothing.
TO PRESERVE THE QUALITY OF YOUR WATCH

TO PRESERVE THE QUALITY OF YOUR WATCH


(Protect the watch body from water splashes by wrapping it up in plastic wrap etc.)
• When the band becomes less flexible, have the band replaced with a new one. If you continue to use
the band as it is, the band may develop cracks or become brittle over time.
1 Lift up the flap approximately
90°until it stands upright, and
Flap
20° 90°
then press the flap down
● Silicone band further approximately 20°and
• As for material characteristics, the band is easily dirtied, and may be stained and discolored. lightly hold it.
Wipe off dirt with a wet cloth or cleaning tissue. • When doing so, take care not to push
• Unlike bands of other materials, cracks may result in the band being cut. Take care not to damage the the flap forcibly. Although you may feel
band with an edged tool. slight resistance, doing this requires
only a light force.
Notes on skin
irritation and
Skin irritation caused by a band may result from various factors such as allergy to
metals or leathers, or skin reactions against friction on dust or the band itself.
2 Lightly pull the band on the
6 o’clock side of the watch Band on the
6 o’clock side
allergy along the curved line of the
of the watch
band to pull out the slider.
Adjust the band to allow a little clearance with your wrist to ensure proper • Doing this requires only a light force.
Notes on the airflow. Take care not to pull the band forcibly.
length of the band When wearing the watch, leave enough room to insert a finger between • The slider can be pulled out
the band and your wrist.
approximately 30 mm. Take care not
to pull it out more than this limit.

EN 37 EN 38

3 While pressing the push


button, lift up the clasp to
Clasp Push button
How to use the diver extender
release the buckle, and place If your watch’s metallic band has the Diver Extender function, the length of the band can be easily
2 the watch on your wrist. adjusted. 2
It is very useful when you wear the watch over a wet suit or winter clothing.
TO PRESERVE THE QUALITY OF YOUR WATCH

TO PRESERVE THE QUALITY OF YOUR WATCH


1 Lift up the flap.
Flap
4 Close the clasp (4-1) first and
then, the flap (4-2).
Flap
(4-2)
Clasp
(4-1)

2 While pressing the push


button, open the clasp.
Clasp

5 Hold both sides of the band to


adjust the length of the slider
• After opening the clasp, push the flap
back to the normal position for safety’s
until it fits snugly around your sake.
wrist.

Push button

EN 39 EN 40
3 Open the two-piece foldover
portion of the Diver Extender in
After sales service
the direction of the arrow.
2 • Some force is required to open the ● Notes on guarantee and repair 2
foldover portion, and it will click when
it is opened. • Contact the retailer from whom the watch was purchased or SEIKO CUSTOMER SERVICE CENTER
TO PRESERVE THE QUALITY OF YOUR WATCH

TO PRESERVE THE QUALITY OF YOUR WATCH


for repair or overhaul.
Two-piece foldover portion of the Diver • Within the guarantee period, present the certificate of guarantee to receive repair services.
Extender • Guarantee coverage is provided in the certificate of guarantee.
Read carefully and retain it.

4 Slide the upper cover of the • For repair services after the guarantee period has expired, if the functions of the watch can be restored
Upper cover of the Diver Extender by repair work, we will undertake repair services upon request and payment.
Diver Extender in the direction
of the arrow, and then, pull it up
to extend the two-piece ● Replacement with functional parts
foldover portion to the full • Please keep in mind that if original parts are not available, they may be replaced with substitutes whose
extent. outward appearance may differ from the originals.

5 Place the watch on your wrist,


and close the clasp (5-1) first Flap
(5-2)
Clasp
(5-1)
and then, the flap (5-2).
* To fold up the Diver Extender, reverse the
procedure above. When the two-piece
folder portion of the Diver Extender is
folded up completely, it also clicks in the
same manner as when it is opened.

EN 41 EN 42

● Inspection and adjustment by disassembly and cleaning (Overhaul)


• Periodic inspection and adjustment by disassembly and cleaning (overhaul) is recommended
Accuracy of mechanical watches
approximately once every 2 to 3 years in order to maintain optimal performance of the watch for a long
2 time. ○ The accuracy of mechanical watches is indicated by the “daily rate.” 2
• The power transmission gear of the movement of this watch constantly receives force. To ensure that
this mechanism works properly all the time, washing parts, changing oil, adjusting accuracy, checking ○ The accuracy of mechanical watches may not fall within the specified
TO PRESERVE THE QUALITY OF YOUR WATCH

TO PRESERVE THE QUALITY OF YOUR WATCH


functions and replacing consumable parts on a regular basis are important. The first overhaul after the
purchase of your watch is particularly important for preserving long-time use of your watch. According range of time accuracy because loss/gain changes according to the
to use conditions, the oil retaining condition of your watch mechanical parts may deteriorate, abrasion position of the watch, which is dependent on the conditions of use,
of the parts due to contamination of oil may advance or delay the time significantly, or the watch itself
may stop. such as the length of time during which the watch is worn on the wrist,
As the parts such as gasket may deteriorate, water resistant performance may be impaired due to arm movement, and whether the mainspring is wound up fully or not,
intrusion of perspiration and moisture.
Inspection and adjustment by disassembly and cleaning (overhaul) should be performed by the retailer
etc.
from whom the watch was purchased, and who specifies “SEIKO GENUINE PARTS.” At this time, also
request replacement of the gasket and the spring bar. ○ The loss/gain of mechanical watches is not measured by a daily rate,
• When your watch is inspected and adjusted by disassembly and cleaning (overhauled), the movement but by daily rates of one week or so.
of your watch may be replaced.
○ Accuracy variation according to temperature
b CAUTION The parts that compose the accuracy of mechanical watches are made of metals. It is well known that
metals expand or contract depending on temperatures due to metal properties. This exerts an effect on the
Depending on the environment where a diver’s watch is used, its inner parts or movement accuracy of the watches. Mechanical watches tend to lose time at high temperatures while they tend to
as well as its case or band may be affected. We recommend that you have your watch gain time at low temperatures.
overhauled regularly once every 2 or 3 years.

EN 43 EN 44
○ Mainspring wound condition and accuracy
In order to improve accuracy, it is important to regularly supply energy to the balance that controls the speed
Troubleshooting
of the gears. The driving force of the mainspring that powers mechanical watches varies between when
Troubles Possible causes Solutions
2 fully wound and immediately before it is unwound. As the mainspring unwinds, the force weakens.
Wind up the watch as per “How to wind the
2
Relatively steady accuracy can be obtained by wearing the watch on the wrist frequently for the self-winding
The watch stops mainspring” → (P.18), and set the time. If the
TO PRESERVE THE QUALITY OF YOUR WATCH

TO PRESERVE THE QUALITY OF YOUR WATCH


type and winding up the mainspring fully everyday at a fixed time to move it regularly for the wind-up The mainspring has not been wound.
operating. watch still does not operate, consult the
mechanical type. retailer from whom the watch was purchased.
Return the watch to a normal temperature so
○ Effect of magnetism that it works accurately as usual, and then
When affected by a strong magnetism from outside, the mechanical watch may lose/gain time. The parts The watch has been left in extremely high or reset the time. The watch has been adjusted
of the watch may become magnetized depending on the extent of the effect. low temperatures for a long time. so that it works accurately when it is worn on
In such a case, consult the retailer from whom the watch was purchased since the watch requires repair your wrist under a normal temperature range
between 5°C and 35°C.
including demagnetizing.
Accuracy cannot be recovered. Restoring the
The watch gains/loses The watch has been left close to an object original accuracy requires demagnetization
time. with a strong magnetic field. (repair). Consult the retailer from whom the
watch was purchased.
You drop the watch, hit it against a hard If accuracy does not return after setting the
surface, or wear it while playing active sports. time, consult the retailer from whom the watch
The watch is exposed to strong vibrations. was purchased.
The watch has not been overhauled for more Consult the retailer from whom the watch was
than 3 years. purchased.

EN 45 EN 46

Troubles
The date changes at
Possible causes Solutions
Specifications
AM/PM is not properly set. Advance the hands by 12 hours.
12 o’clock noon.
Cal. 4R35 4R36
2 Blur in the display A small amount of water has got inside the Consult the retailer from whom the watch was
1. Features 3 hands (hour, minute, second), date 3 hands (hour, minute, second),
2
persists. watch due to deterioration of the gasket, etc. purchased.
display date/day of the week display
TO PRESERVE THE QUALITY OF YOUR WATCH

TO PRESERVE THE QUALITY OF YOUR WATCH


* For a solution to a problem other than listed above, contact the retailer from whom the watch was purchased.
2. Vibrations per hour 21,600 vibrations/hour (6 vibrations/sec)
3. Loss/gain (daily rate) +45 to -35 seconds at normal temperature range
Only if worn on the wrist in a temperature range of 5°C to 35°C
4. Driving system Automatic winding type with manual winding mechanism
5. Duration Approx. 41 hours
6. Jewels 23 jewels 24 jewels
* The accuracy above is factory-adjusted.
* Due to the characteristics of mechanical watches, any actual daily rate may not fall within the range of time accuracy
specified above dependent on the conditions of use, such as the length of time during which the watch is worn on
the wrist, temperature, arm movement, and whether the mainspring is wound up fully or not, etc.

EN 47 EN 48

You might also like