Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

EN119二合一

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

2IN1 HARI REMOVAL BEAUTY MACHINE

User Manual

1
Welcome to use our 2in1 Hari Removal Beauty system.The system uses diode laser and offers
painless permanent hair reduction &Tattoo Removal.

CONTENTS

Welcome

Page
1. Attention 3
2. Package list 3
3. Technical specification 3-4
4.Machine Principle 4
5.Basic machine structure 5
6.808nm hair removal handle 6
7.ND YAG HANDLE 7
8.Three Wavelengths
8
9.Machine Installation
89
10.808nm Operation 10.11.12
11.ND YAG system manual 12.13.14
12.Treatment Notice
14.15
13.Maintenance 15
14.Warranty Notice 15
15. Exception Handles 16

Note: Please do not open the machine before you read

this user manual!

2
1. Attention:
1. our Diode Laser Hair Removal Machine could emit the high-intensity infrared laser beam. Please
follow some operation regulations:
 According to the standard of NOHD, please wear the suitable protection glasses for operator and
patient in order to protect the eyes,
 Please do not point the laser at the eyes directly.
2. Please make sure to be familiar with the structure and manual before operation.
3. Diode Laser Hair Removal Machine is only allowed to be used by people who had enough safety and
operation training.
Please turn off the cooling function, when the machine is in standby state, otherwise the probe will be
easily damaged.
4. If this is the first time you use Diode Laser Hair Removal Machine, please read the User Manual
carefully before operation.
5. Please do not use the Hair Removal Machine in the environments which contain flammable
anaesthetic and oxidized gas, such as N2O and O2. Some material, such as cotton or wool textile, will be
ignited in the environment which is rich in oxygen during Hair Removal machine running.

2. Package List

Part Quantity Note


Laser Machine 1 SET Laser machine with case
Handle 2 SET ND YAG+808 Handle
Power Supply Line 1 PC Not attached for Frame machines
Pedal Switch 1 PC
Funnel 1 PC
Patient Goggles 1 PC
Operator Safety Glasses 1 PC
User Manual 1 SET Sent by email

3.Technical Specifications

3
Model our

Input VAC 220VAC / 50-60Hz

Cooling Temperature -5℃--5℃

System Cooling method Water+Fan+TEC+Sapphire

Interface Language English

Aluminum Case Dimension (Machine) 56*57*117cm


Main
Mechine Screen 15.6’ 1920 x1080 Color Touch Screen

Gross Weight 55KG

Laser Cooling Liquid Pure water

Water Tank Volume 5-6 L

Working Environment Temperature 15~28℃

Environment Moisture <70%

Wavelength 808nm

Power 800W/1000W

808 Handle Pulse Width 1ms~400ms

Frequency 1Hz~10Hz

Spot Size 13*30/13*40mm

Wavelength 1064 &532 &1320nm (Nd Yag)

Power 500w
Nd Yag
Handle Pulse Width 1ms~200ms

Frequency 1Hz~10Hz
Function Tattoo Removal,freckle remova,letc

4.Principle of hair removal

808 nm diode laser hair removal machine is accomplished when destroying the hair
follicularunit by thethermal damage of laser fluence and thus inhibiting future hair
regrowth by thefollicle.Thewidely optional pulse duration (50 to 1000ms) of 808nm
diode laser system canproduce thermaldamage in hair matrix stem cells and ensure
follicular destruction.In orderto minimize theuncomfortable of thermal damager to
surrounding skin cells, an efficient skin-cooling system( Sapphire contact cooling tip)
is used to chill the skin before, during and afterthe hair removaltreatment. Therefore,
808diode laser is more effective for hair removal inpatients with dark skin as well.

4
5.Basic machine structure

ND YAG Handle 808nm Handle

15.6*Color Touch Screen

Light Indicator Emergency Switch

Key Switch

5
6.808nm hair removal handle

13*40mm Suitable for arms,legs, back, abdomen, chest.

6
7.ND YAG HANDLE

Widely applications of q-switched nd yag laser:

1.-532nm wavelength: get rid of freckles, eyebrow tattoo, failed eye line tattoo, tattoo
, lips line, pigment, telangiectasia in shallow red, brown and pink and etc. light color
2.-1064nm wavelength: get rid of freckles and yellow brown spot, eyebrow tattoo,
failed eye line tattoo, tattoo, Birthmark and Nevus of Ota, pigmentation and age spot,
nevus in black and blue, scarlet red, deep coffee and etc. deep color.
3.-1320nm wavelength: shrink pores removal, poblackhead removal, skin tightening
and whitening, skin rejuvenation, wrinkle removal.

7
8.Three Wavelengths

THREE WAVELENGTHFLEXIBLE CONFIGURATION


755nm, 808nm,1064nm three wavelength flexible configuration, all
kinds of skin color hair removal can achieve satisfactory results

9.Machine Installation

Do not power up the system before you read this manual!

1. Please check all the parts in package list to confirm all are received.
2. Add water to water tank. Please confirm your machine model.
our has import aser stack
in thehandle piece. It needs DI-water,otherwise laser handle piece is easily broken.
Operation
way is as follows.
A. Connect water valves to water inlet and Unscrew the drain screw at the same time.
B. Connect the funnel to the water valve of water inlet, then add water. .
When water overflows fro the water drain, it means water is enough.
C. After operation, you need to take water vavels away.

8
water drain
inlet screw

Water Valve
3. Connect the handle piece to main machine. Check the handle piece if it is in good condition.
Make sure the water tube is well connected. You will hear “click” when the water connector of hand
piece are well locked. Otherwise, there will be water leakage or water jam, which may cause water
pump broken or laser burning out.
1) Please confirm if your wall-plug is 200-240VAC. If it is 90-120VAC, please use voltage
transformer.
2) Find a 10A 220-250V VAC plug wire (you may need an European Model for the wire), connect to
the back panel.
3) Check if the emergency button(Red Mushroom) is pressed down. If pressed down, please rotate
as per arrow direction to rebound.

4.Use the key to start the system and you will enter the welcome interface of the 808 Diode Laser
system as below:

Welc ome In te rfa c e In te rfa c e A


5) Press the welcome interface, you will enter the second page as the right picture above. Till now,
you are successfully enter the hair removal system. Please follow the “6. OPERATION” chapter
to start the treatment.
6) For any emergency situation, please press the emergency button (Red Mushroom) to shut down
the laser immediately.
7) After treatment, if you want to turn off the system, you can use the key to shut it down directly.
And turn off the air switch at the back panel. You can remove the VAC plug if necessary.

1. Welcome Interface
Here is a welcome page. Just press “Start” Bottom , you will enter the second page.2
. Interface A
In this page, you can select one of the handles, and press “Enter” to confirm.

9
2. InterfaceB
In this page, you can choose the working mode, the size of the treatment area, the skin color, and the
treatment area.

In t e rfa c e B

10.808nm diode laser Operation

SHR Pa ge

SHR

When you enter into SHR Page,you can adjust fluence and energy by “△” and “▽”. In addition, you can
press”Save” to keep your preferred parameter in record,then you can use the new parameter in next
treatment.

10
There are totally 3 parameters to be set, including: Fluence, PULSEWIDTH and FREQUENCY.
1) Fluence shows energy value of a single pulse laser per unit area. The step width is 1J/cm². You
can adjust it by pressing “△” and “▽”.
2) PulseWidth represents the time of each light exposure. PulseWidth can be variable from
1ms-400ms(1ms-200ms) with a step width of 1ms.
3) Frequency is the number of times a light shines per second. You can adjust it by pressing “△”
and “▽” from 1-10Hz with a step width of 1Hz.
(Please refer to explanation of “SHR Mode” for HR and SHR STACK buttons)
4) Number of Grids shows recommended parameter. Please refer to the following parameter sheet.

Number of Grids Treatment time(s)


1 200
2 400
3 600
4 800
5 1000
6 1200
7 1400
8 1600
9 1800
10 2000
11 2200
12 2400

5) Sec shows treatment time. It is set by Number of Grids and countdown, when it becomes “0”,
treatment is finished.
6) Home means back.
7) Save is to keep your preferred parameter.
8) Reset is to back to recommended parameter quickly.
9) Setting is used to set the system parameters. The appearance has been set without the need
for user Setting.
10) Language is used to set the Language.
11) INFO is used to display system information.

12) In this condition, you can set the parameter.

13) It means that the machine is working, you can’t set the parameter.

14) It shows the system status.


A. Status: Water temperature high. The cooling water temperature range should be between
15~35℃. If it is higher than 35℃, the laser will stop. Please wait till water temperature going
down. The warning will disappear, and system can be set again.
B. Status: Water flow rate low. It means the cooling water flow rate lower than minimum
requirement. If the water flow rate ,which show at the bottom of the screen, is just low, not “0

11
L/min”. Please first check along the water tube to confirm whether there are any jam in it and
handle piece water connector are well locked. Secondly, open the water inlet at the back of
machine to make the air pressure balance between the inside and outside of water circle
system. If the water flow rate shows “0 L/min”. Please first check whether the water pump
are working. Or contact our company to ask for help.

15) Set the parameters (Fluence, Energy) and press ” ” button to enable the handle piece.
The cooling of handle piece is controlled by software program automatically. Don’t keep the
handle piece in ‘ Ready’ state for long time. For the typical treatment parameters, you can refer
to the recommended default or experienced doctor’s advice.
16) Take the handle piece. Press the pedal switch or the switch on the handle piece to shot the laser
pulses. Keep pressing the button and the laser output will continue. Do not press & release for
single pulse.
17) You can stop the machine anytime by turning off the key on the front panel or by pressing
emergency button.

11.ND YAG laser system manual

● Power on operation:
1. connect well the power supply,Turn on the power switch (at the power outlet)
and opening the key switch to enter the system. as shown in the figure:

12
2. Click the default 1064 mode or other mode to display the following picture.

3 .Select menu according to treatment needs, 1064, 532.755 can be selected.


The following picture shows the entry into the 1064 work and parameter adjustment
interface:

Energy display Frequency display

Return
button

Energy adjustment Ready button Frequency adjustment

13
prompt
The temperature is too high,indicating that the water temperature is too high
Please let themachine stand by for 30 minutes.

●Useof 532nm converter:


The handle sight l064nm,1320nm ,532nm converter is toggled; the other methods of operation
are the sam .

Note : The 532anm wavelength laser is harmful to the human epidermis and must be read
andunderstood in detai1.

Disinfection
Before each treatment and after treatment,wipe the handle with the gauze or cotton swab and
75% medical alcohol for l~2 times.

12.Treatment Notice

1. The treatment of the hair removal needs experienced professionals. Do not use it if you have
no experience for such kind of laser device.
2. Operators and patients must wear laser goggles to protect eyes from any laser damage threat.3
. Please notice that this is a high power laser device and if the patients feel very painful, please
stop the laser and check if there is anything happening to the patients’ skin. Adjust it as a proper
power that the patients can stand to do the tr light color, you can adjust the laser power up to
25~40J/cm2. For light color to light brown, you need a lower laser power (10~15J/cm2 for example),
Also you need to use lower than 10J/cm2 and extend the treatment time for the dark skin to inject
enough energy to the skin and follicles.
4. The skin must be cleared, shaved and applied cooling gel before treatment. Do not scratch the
surface skin, do not use hair removal cream or wax to remove hair.
5. You need to wait for several minutes before the cooling tip becomes cold.

14
6. The cooling Sapphire should be applied on the skin tightly. And you can also use the edge of
the Aluminum head of the handle piece to cool down the skin during treatment.
7. Never shot the laser pulses to eyes, or watch the laser directly.
8. Require customers not to have sun exposure within a week, and no other skin damage.

13.Maintenance
1. It’s better to replace pure water once per month.
2. The machine must be operated in a room with air-conditioner. The room temperature is better
<28°C.
3. The environment temperature can not go below ZERO, or the ice may damage the water tanks
and water channels inside the machine and the handle piece.
4. Clear the gel on the handle piece and make sure there is no dust around the Sapphire.
5. Do not bend the tube of the handle piece too hard, or this may cause water flow rate low
warning.
6. Do not plug in & out the handle piece connectors frequently. This may cause water leakage or
water jam or bad electrical connections.
7. Do not shot the laser at random targets, or it may cause burning or fire.
8. Always keep the handle piece with the holder on the main machine when you don’t use it.
Otherwise, the condensing water may flow back to the laser stack in handle piece, so that cause
laser failed.
9. If you won’t use the machine over 2 weeks, please draw off the water from the machine.
A.Connect water valves to water drain and water outlet at the same time.
B.Connect the funnel to the water valve of water outlet, then water flows out. Be sure to use a basin
to catch the water.
C.After operation, you need to take water vavels away.

14.Warranty Notice
Please take necessary protections for the operation of the machine and handle piece, and notice
that following situations can not be warranted:
1. Operation the system without water.
2. Power up the system without connecting the handle piece.
3. Regular drops of the handle piece.
4. Wrong input VAC.
5. Other manual operating mistakes.

15. Exception Handles

15
After starting the hair removal machine by key switch, the system will enter self-check program, if some
parts of machine has problem, there will be a warning showing in the “Status” column” on the screen,
and warning sound can be heard at the same time.

1. Status: Water temperature high. The cooling water temperature range should be between
15~35℃. If it higher than 35℃, the laser will stop. Please wait till water temperature going down.
The warning will disappear, and system can be set again.
2. Status: Water flow rate low. It means the cooling water flow rate lower than minimum
requirement. If the water flow rate, which show at the bottom of the screen, is just low, not “0 L/min”.
Please first check along the water tube to confirm whether there are any jam in it and handle piece
water connector are well locked. Secondly, open the water inlet at the back of machine to make the
air pressure balance between the inside and outside of water circle system. If the water flow rate
show “0 L/min”. Please first check whether the water pump are working. Secondly, take down the
water flow sensor to check whether there are jam in it. Or contact our company to ask for help.
3. Status: Operation wrong. Start treatment without enter ready status.
4. Water pump shuts off. There is a thermal overload protected motor. The motor will
automatically shuts off as temperature rises due to an overload condition. If the motor shuts off in
this manner, close all nozzles, faucets or valves. After a cooling period, the pump will automatically
re-start. To avoid this problem, please first make sure all the water connector are well connected.
Secondly, open the water inlet to make the balance of air pressure between inside and outside of
the water circle system, then let the water pump working for a while, the water flow rate should rise
up.

16