GENERAL NOTES
CONCRETE POST
2. ALL WIRING INSTALLATION SHALL BE CONCEALED FROM VIEW AND INSTALLING THE
CONDUCTORS IN POLYVINYL CHLORIDE CONDUIT (PVC) AND RIGID STEEL CONDUIT (RSC)
WHEN USED AS SERVICE ENTRANCE.
KILOWATT HOUR
METER
3. MINIMUN SIZE OF CONDUCTORS SHALL BE 3.5 mm2 THHN (NO. 12 AWG) AND OF CONDUIT
1
CONDUIT SHALL BE 15mm DIA. ( 2") NOMINAL DIAMETER, UNLESS OTHERWISE SPECIFIED ON PLANS.
4. NO BRANCH CIRCUIT WIRING IN LIGHTING AND POWER SHALL HAVE A LOAD MORE
PANEL BOARD THAN 80% OF ITS RATING.
7. WHENEVER REQUIRED AND NECESSARY, ALTHOUGH SUCH BOXES ARE NOT INDICATED ON
PLANS.
8. FOR EACH SPARE CIRCUIT IN PANELBOARD, PROVIDED AN EMPTY CONDUIT 20mm DIA.
CKT FIN. FLOOR LINE 3
(4") TERMINATING TO A COVERED SQUARE BOX.
2 2-8.00mm2 TW IN 9. ALL MATERIALS AND EQUIPMENT TO BE USE SHALL BE BRAND NEW AND OF APPROVED
32mm DIA. PVC TYPE AS TO LOCATION AND PURPOSES.
10. SERVICE ENTRANCE SHALL BE 230 VOLTS, SINGLE PHASE, THREE-WIRE, 60 HERTZ.
RISER DIAGRAM
NOT TO SCALE
LEGEND:
SCHEDULE OF LOADS
NO. OF
CIRCUIT NO. DESCRIPTION OUTLET WATTS VOLTS AMPERE CKT. BKEAKER SIZE OF WIRE
COMPUTATIONS:
2 DUPLEX CONVENIENCE OUTLET 10 2000 220 9.91 20A
COMPUTATIONS:
PROJECT TITLE: PROJECT OWNER: DRAWN BY: SHEET CONTENT