1850 TSS-320 R3-4 DS
1850 TSS-320 R3-4 DS
1850 TSS-320 R3-4 DS
The Alcatel-Lucent 1850 Transport Service Switch (TSS)-320 is a next-generation, Packet Optical Transport (POT) platform that supports any mix of traffic, from all-circuit to all-packet. Its unique universal matrix seamlessly switches packets or circuits in their native format, cost effectively transforming from Time Division Multiplexing (TDM) to packets. With the Alcatel-Lucent 1850 TSS-320, businesses can begin with circuit-based transport and, over time, gradually ramp up packet transport by simply changing line cards. The Alcatel-Lucent 1850 TSS-320 supports current traffic requirements while eliminating the scalability issues encountered when traditional multiservice provisioning platforms are confronted with the high growth of packet-based traffic.
The Alcatel-Lucent 1850 TSS-320 offers the flexibility to split increasing traffic demands among any combination of Carrier Ethernet, Transport Multiprotocol Label Switching (T-MPLS), wavelength division multiplexing (WDM), optical data unit (ODU) and SONET/SDH transport technologies. It offers powerful cross-layer network management and a unified control plane, simplifying operations and reducing the total cost of ownership (TCO).
Protection and Restoration Combined (PRC) Carrier Ethernet service through T-MPLS for standards-based connection-oriented packet transport SONET/SDH Optical Transport Hierarchy (OTH) switching, including high order/low order (HO/LO) Synchronous Transport Signal (STS) and virtual circuit (VC) switching Very Long Haul (VLH)/Ultra Long Haul (ULH) support Asynchronous Transfer Mode (ATM) pseudowire transport and gateway functions Dense and coarse WDM (DWDM/CWMD) Transport-oriented operations, Operations, Administration and Maintenance (OAM) and Generalized Multi-protocol Label Switching (G-MPLS)
Features
Unique, universal switch architecture Switches packets or circuits in their native format Accommodates any traffic mix, from all-circuit to all-packet Offers TDM and packet line cards for technology-specific processing Fully integrates photonic, optical and data layers Any transport-technology mix
Synchronization for transport networks: SONET/SDH G.813 synchronization including Software State Manager (SSM) Synchronous Ethernet (Sync-E) with SSM Full interworking between TDM and data synchronization, including SSM messages for supporting timing redundancy Transparency to 1588v2 for Time of Day (ToD)
Benefits
Switches any combination of packets and circuits in their native formats using a single platform Fully scales packet transport, smoothly progressing from all-circuit to allpacket, allowing service providers to transform networks to packet transport Efficiently aggregates and grooms metro and long-haul transport
Maximizes the use of existing infrastructure by using WDM Reduces TCO and simplifies operations through cross-layer network management and unified control plane Supports a broad range of applications, such as triple play services, business Ethernet and mobility backhaul
Technical specifications
Alcatel-Lucent 1850 TSS-320 system, 1850 TSS-320 subrack
16 slots, 20 Gb/s per slot: 32 half slots, 10 Gb/s per half slot Two 320 Gb/s protected switching fabrics Two protected controllers Protected power supply Up to two subracks in a standard ETSI or ANSI rack
Fixed Optical Add-Drop Multiplexer (OADM) DWDM cards (packs) 8 channels MUX/DEMUX, L1 band 8 channels MUX/DEMUX, L2 band Optical amplifier 22/9 17 dB 10GB transponder, client and line pluggable: XFP
Interfaces
Data cards 10 x Gigabit Ethernet (GigE) packet module, Small Form Factor Pluggable (SFP) 10GigE packet module, 10 Gb/s Form Factor Pluggable (XFP) Multiservice packet over SONET/SDH (PoS) packet module (portless) ATM gateway packet module (portless) SONET/SDH cards 1 x OC-192/STM-64: XFP 4 x OC-48/STM-16: SFP 8 x OC-3-12/STM-1-4: SFP 10 x any port card: A data/TDM concentrator: SFP 1 x optical transport unit (OTU)-2: 10 Gb/s bidirectional transponder, tunable optics VLH/ULH cards 10 Gb/s booster +10 dBm 10 Gb/s pre-amp +10 dBm CWDM cards CWDM: Multiplexer/ demultiplexer (MUX/DEMUX) CWDM optical add/drop multiplexer (OADM) CWDM transponder
Link aggregation Jumbo-frame management Y.1731/802.1ag OAM: Continuity check (CC), link trace (LT), loopback (LB) Y.1731/802.3ag Eth ASI, Eth RDI Y.1731 Eth OAM DM two-way 802.3ah OAM: Ethernet in the first mile (EFM) Eight Quality of Service (QoS) classes Two levels Hierarchical QoS (H-QoS) (per class, per transport service) Ethernet flow, Red/Green/Yellow (RGY) counters L2 control protocol filtering/ tunneling MEF 9, 14 and 21 certified: EPL, EVPL and E-LAN
Ethernet traffic classification
ATM virtual path identifier/ virtual channel identifier (VPI/ VCI) N:1 mapping with PWE3 static configuration ATM QoS, OAM F4, F5: PWE OAM Cell concatenation UNI2UNI
T-MPLS functionality
Data plane: T-MPLS, MPLS T-MPLS OAM: CV, automatic protection switching (APS), Forward Defect Indication (FDI) RDI: G.8114 T-MPLS OAM DM two-way Tunnel Linear Protection 1:1 Ethernet line (E-line), E-LAN and Ethernet Tree (E-Tree)
SONET/SDH functionality
Cross connection Termination Ethernet mapping over SONET/ SDH Generic framing procedure ((GFP), G.7041) Virtual concatenation Link capacity adjustment scheme (LCAS) Performance monitoring HO and LO capabilities
Port Ethernet VLAN Ethernet priority bits IPv4 differentiated services code points (DSCP) EtherType MPLS Exp bits
Ethernet forwarding criteria
Ethernet functionality
Ethernet protocol: 802.3 Ethernet Media Access Control (MAC) auto-learning and aging Ethernet-MAC static configuration Access Control List (ACL) Virtual LAN (VLAN) push, pop, swap: Service delimiting Ethernet virtual bridging: 802.1Q Ethernet provider bridging: 802.1ad Q in Q Rapid Spanning Tree Protocol (RSTP) and Multiple Spanning Tree Protocol (MSTP)
Port Port plus MAC Port plus VLAN Port plus MAC plus VLAN Port plus MAC plus VLAN plus Prio bits Unicast traffic Multicast traffic Broadcast traffic
DWDM functionality
Node configurations Terminal In-line amplifier (ILA) OADM Network configurations Point-to-point Linear Ring
ATM functionality
Pseudowire emulation edge to edge (PWE3): ATM-PWE3 gateway OC-3/STM-1 ATM unchannelized
Protection
Ethernet network protection RSTP: 802.1w MSTP: 802.1s Link aggregation T-MPLS network protection Tunnel Linear Protection 1:1 Protection and Restoration Combined (with G-MPLS) SONET/SDH network protection Single- and dual-ended APS 1 + 1 Subnetwork Connection Protocol (SNCP), unidirectional path-switched ring (UPSR) Multiplex Section-Protection Ring (MSPRING) 2F bidirectional line switching ring (BLSR) Equipment protection Power protection Controller protection Universal switch protection
Physical specifications
ANSI
Dimensions: 1850 TSS-320 subrack
Subrack dimensions Height: 624 mm (24.6 in.) Width: 532 mm (20.9 in.) Depth: 304.8 mm (12.0 in.)/ 355.6 mm (14.0 in.) Designed to be installed in a standard ANSI rack Height: 2.13 m (7 ft) Width: 660.4 mm (26.0 in.) Depth: 304.8 mm (12.0 in.)/ 355.6 mm (14.0 in.)
Power and cooling
Power supply: DC feed (-48 V DC nominal) Power supply: -65 V Power consumption: Up to 3500 W Cooling: Forced air
Environment
Operating temperature: -5C to +45C (23F to 113F) Relative humidity: 0% to 90%, non-condensed
Regulatory compliance
CE certification Operating conditions: ETS 300 019, Class 3.2 Storage conditions: ETS 300 019, Class 1.2 Transportation conditions: ETS 300 019, Class 2.2 Electrostatic discharge (ESD)/ electromagnetic compatibility (EMC): ETS 300 386 Telecommunications Center
Power supply: DC feed (-48 V DC nominal) Power supply: -58 V Power consumption: Up to 3500 W Cooling: Forced air
Environmental
Fault propagation
Link Pass Through (LPT) Link Loss Carry Forward (LLCF) Fault propagation tools: GFP CSF/SSF, Ethernet CSF
Operating temperature: -5C to +45C (23F to 113F) Relative humidity: 0% to 90%, non-condensed
Regulatory compliance
Management
Alcatel-Lucent 1350 Optical Management System (OMS) TL1 Zero-installation craft (ZIC) terminal Simple Network Management Protocol (SNMP) Command line interface (CLI) Secure Shell (SSH) v2/Secure Socket Layer (SSL) for secure connection
Subrack dimensions Height: 624 mm (24.6 in.) Width: 532 mm (20.9 in.) Depth: 288 mm (11.3 in.) Designed to be installed in a standard ETSI rack Height: 2.20 m (86.6 in.) Width: 600 mm (23.6 in.) Depth: 300 mm (11.8 in.)
www.alcatel-lucent.com
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Copyright 2010 Alcatel-Lucent. All rights reserved. CPG4688100501 (05)