Biotek Product Catalog
Biotek Product Catalog
Biotek Product Catalog
Agilent BioTek life science instrumentation addresses a broad range of applications in imaging and microscopy, multimode
microplate detection, associated liquid handling, and assay automation. Browse our growing list of timely research
applications, and see how BioTek instrumentation can facilitate even the most complex workflows.
3D cell culture
Some of the most commonly incorporated technologies to create the
desired 3D spheroids or tumoroids include polymeric and biological
scaffolds, ultralow attachment, hanging drop, and magnetic bioprinting. 3D
workflows are performed in a variety of microplate types, and are commonly
analyzed using microplate reader optics or digital widefield microscopy.
Immunofluorescence
Immunofluorescence reagent options range in scope from individual
primary antibodies, to out-of-box multiplexed assay solutions for cell
signaling pathway analysis. The basic IF workflow can be labor-intensive,
thus benefits from automation in order to manage assays in microplates,
microscope slides, Petri dishes, and cell culture inserts.
Biomarker assays
Quantitative determination of specific mRNA and protein biomarkers in cells
can be performed using either conventional microplate reading, to obtain an
averaged cell population result, or digital widefield microscopy, to provide
individual cell responses and the spatial location of a molecular biomarker.
Biomarker assays are commonly run in higher density microplates using
automated microscopy and multimode detection, as well as automated liquid
handling for sample preparation through to reagent addition.
Phenotypic assays
Phenotypic assays provide quantitative cellular structure and function data,
measured using digital widefield microscopy. They are used to assess whether
a compound or drug produces a desired effect on the cells. Agilent BioTek Gen5
software can analyze multiple cellular phenotypic parameters simultaneously,
including size, shape, area, and intensity. This can provide a comprehensive
picture of individual cell phenotypes and entire population phenotypes, which
4 allows a researcher to make an educated decision.
Applications
Cell-based assays
Microplate readers have adapted to accommodate advances in, and the
complexities of, cell-based assays. Highly sensitive detection modes, such
as time-resolved fluorescence, aid in the development of robust assays using
cell lines or primary cells. Environment control within the detection chamber
enables long kinetic readouts. Many of these assays are now incorporated
into screening campaigns, where sample throughput and automation are of
prime importance.
5
Applications and Scientific Support
Scientific achievement is reliant upon the successful union of experimental design, instrumentation, and analysis. The FAS team is
focused on your research goals and helping you to realize your innovative ideas throughout the purchase process. From
predemonstration through to ownership, we’ll provide you with:
6
Applications and Scientific Support
Post-demonstration summary report with data, images, and protocols for you
to keep
All data and images are available to you during and after your demonstration, including a custom
summary report. Furthermore, all Gen5 or Gen6 protocols generated are saved and shared upon
purchase, so you can begin your work as soon as your instrument arrives.
To request service for Agilent BioTek products, please navigate to: https://www.agilent.com/en/
contact-us/page to find the contacts relevant for your region.
7
Imaging and Microscopy
The Agilent BioTek Lionheart FX automated microscope enables image capture and analysis with
a combined power and ease of use that sets it apart from traditional microscopes. Lionheart FX
and Agilent BioTek Gen5 microplate reader and imager software capture and produce detailed
information from live cell assays in real time, providing valuable qualitative and quantitative data
quickly and easily. Augmented Microscopy is the collection of all of these features in one compact
system. With Lionheart FX, you can capture, process, analyze, annotate images, and produce
videos with ease.
Lionheart FX offers fluorescence, brightfield, color brightfield, and phase contrast imaging
modes to cover a broad range of applications. With four channels and more than fifteen color
cubes available, Lionheart FX is compatible with a wide range of fluorophores for multicolor
imaging. With magnification of 1.25x to 60x (air), and 60x and 100x oil immersion magnification,
as well as new tools in Agilent BioTek Gen5 Image Prime software, the image capture and
analysis streamlines the workflow. The automated six-position objective turret provides quick
selection of optimal imaging magnification.
With Lionheart FX, live cell assays can be measured over seconds, minutes, hours, or days. The
environmental control cover ensures the required temperature and gas circulation, and provides
a darkroom-like environment for fluorescence imaging. A humidity chamber offers added
protection for cells during long-term measurement, and the new Agilent BioTek AutoScratch
wound making tool automates sample preparation for all migration assays. The dual-reagent
injectors provide rapid sequential dispensing and imaging to capture rapidly changing cellular
activities.
8
Imaging and Microscopy
Technical details
General Objectives Available Fluorescence:
Air: 1.25x, NA: .04; 2.5x (2.25x eff), NA: .07;
Microplate Types 6- to 1536-well plates
2.5x (2.75x eff), NA: .12; 4x, NA: .13; 10x, NA: .30; 20x, NA:
Other Labware Microscope slides, Petri and cell culture dishes, .45; 40x, NA: .60; 60x, NA: .70
cell culture flasks (T25, T75), counting chambers Oil: 60x, NA: 1.42; 100x, NA: 1.40
(hemocytometers), chamber slides Phase objectives available: 4x, NA: .13; 10x, NA: .30; 20x,
Support for labware up to 1.5” tall NA: .45; 40x, NA: .60
Temperature Control Incubation to 40 °C with optional environmental control Image Filter Cube Four fluorescence cubes plus brightfield channel; more
cover Capacity than 20 colors available
Dispense Accuracy ± 1 µL or 2%
Camera 16-bit Sony CMOS
Dispense Precision ≤ 2% at 50–200 µL
Camera Exposure Range 5 milliseconds to 4 seconds
Physical Characteristics
Image Outputs Available Raw images: 16-bit TIFF
Saved images: TIFF, JPG, BMP, PNG, EMF, GIF Power Consumption 250 W (maximum)
Movies: MP4, WMV
Dimensions With cover closed or without cover:
Objective Capacity Six onboard, user-replaceable objectives 17.9” W x 18.3” D x 14.1” H (45.5 x 46.5 x 35.8 cm)
With cover fully open:
17.9” W x 18.3” W x 27.5” D (45.5 x 46.5 x 69.8 cm)
Weight Without environmental control cover: 51 lb (23.1 kg)
With environmental control cover: 58 lb (26.3 kg)
9
Imaging and Microscopy
Lionheart LX has an automated six-objective turret and can contain up to four LED/filter cubes
for multichannel image capture. The precise automated stage and autofocus, auto-exposure, and
other Gen5 software features enable simple, automated image capture and analysis.
With brightfield, color brightfield, phase contrast and fluorescence imaging in four channels, and
more than twenty available LED/filter cubes, Lionheart LX offers versatility. Imaging processing
from Z-stacking to Z-projection; montage collection to stitching, plus analysis from label-free cell
counting to mitochrondrial membrane potential are all accomplished with Lionheart LX and
Gen5 software.
Augmented Microscopy
Augmented Microscopy automates image capture, processing, and analysis workflows for
publication-ready images and data. Image capture starts with image-based and laser autofocus,
plus autoLED intensity and auto-exposure. Automated image preprocessing optimizes images for
downstream analysis, from cell counting to characterization of subcellular details.
Gen5 software makes it fast and easy to obtain cell counts and confluence calculations directly
on the live camera feed from Lionheart LX. Gen5 quickly finds the region of interest and displays
counts onscreen, without needing to capture the image. The quick analyze function works for
samples in a variety of labware.
Lionheart LX integrates all microscopy hardware into a very compact footprint, saving valuable
bench space. The easily accessible objectives and LED/filter cubes make setup and operation
fast and simple, with a minimal learning curve.
10
Imaging and Microscopy
Technical details
General
Other Labware Microscope slides, Petri and cell culture dishes, cell culture flasks (T25, T75), counting chambers (hemocytometers), chamber slides
Support for labware up to 1.5” tall
Software Agilent BioTek Gen5 microplate reader and imager software included
Agilent BioTek Gen5 Secure enables 21 CFR Part 11 compliance (option)
Agilent BioTek Gen5 Image+ and Image Prime software available for full image analysis (option)
Imaging System
Imaging Modes Fluorescence, brightfield, high-contrast brightfield, color brightfield, phase contrast
Imaging Methods Single-color, multicolor, montage, time-lapse, Z-stack, Z-stack montage, burst mode
Light Source High-power LEDs (available wavelengths: 365, 390, 465, 505, 523, 590, 623, 655, and 740 nm)
Objectives Available Air: 1.25x, NA: .04; 2.5x (2.25x eff), NA: .07; 2.5x (2.75x eff), NA: .12; 4x, NA: .13; 10x, NA: .30; 20x, NA: .45; 40x, NA: .60; 60x, NA: .70
Oil: 60x, NA: 1.42; 60x, NA: 1.25; 100x, NA: 1.4; 100x, NA: 1.3
High NA: 20x, NA: 0.75; 40x, NA: 0.95
Image Filter Cube Capacity Four user-replaceable fluorescence cubes plus brightfield channel; more than 20 colors available
Physical Characteristics
11
Imaging and Microscopy
Expertise gained over several years of Cytation development, along with customer feedback, resulted
in the C10: an automated confocal microscope with excellent performance, at an attainable price.
Confocal microscopy enables detailed visualization of samples that are not effectively imaged with
a widefield microscope. Not only can you obtain improved image quality, you can get improved
quantification and analysis with confocal images and Gen5 microplate reader and imager software.
High-quality objectives, filters, and other components, including Olympus objectives, Hamamatsu
sCMOS Orca camera, and Semrock filters are used in Cytation C10, enabling the capture of stunning,
publication-ready images.
With a combination of spinning disk confocal and widefield imaging, plus multimode reader, Cytation
C10 is ready for any assay. And since Cytation C10 is upgradable, you can get the functionality you
need today and add modules later as requirements change.
Cytation C10 captures stunning detail in a wide variety of sample types. Use widefield imaging
for faster acquisition of large samples at lower magnification; switch to confocal to image small
intracellular details or 3D samples. Or, combine both modes for highly multiplexed, multiparameter
imaging experiments.
A consistent environment, including temperature control and CO2/O2 control and monitoring provides
the perfect environment to grow and analyze live cells over time. Cytation C10 can be integrated to
Agilent BioTek BioSpa 8 automated incubator to automate confocal and widefield imaging analysis
workflows.
Capture more light with water-immersion objectives and reduce the potential for phototoxicity in live
cells. The increased signal enables more detailed analyses without increasing gain and noise.
12
Imaging and Microscopy
Technical details
General Image Filter Cube Four user-replaceable fluorescence cubes, plus brightfield
Capacity channel
Detection Modes UV-Vis absorbance, fluorescence intensity, luminescence
Imaging Filter Cubes > 20 color cubes available
Read Methods End-point, kinetic, spectral scanning, well-area scanning Available
Microplate Types Monochromators: 6- to 384-well plates; Autofocus Method Laser autofocus, software autofocus
Imaging: 6- to 1536-well plates
Positional Controls Software control, joystick controller (option)
Other Labware Microscope slides, Petri and cell culture dishes, cell culture
Supported flasks (T25), counting chambers (hemocytometer), Agilent Image Collection Image-based autofocus: 96 wells, 1 color (DAPI), 4x, 6
BioTek Take3 microvolume plates Rate minutes
Laser autofocus: 96 wells, 1 color (DAPI), 4x, < 3 minutes
Temperature Control To 45 °C with Condensation Control
Fluorescence Intensity
Shaking Linear, orbital, double-orbital
Light Source Xenon flash
Software Agilent BioTek microplate reader and imager software
included Detector PMT
Agilent BioTek Gen5 Secure enables 21 CFR Part 11
Wavelength Selection Quad monochromators (top/bottom)
compliance (option)
Agilent BioTek Image+ and Image Prime software available Wavelength Range 250–700 nm (900 nm option)
for full image analysis (option)
Monochromator Variable, from 9–50 nm in 1 nm increments
Automation Agilent BioTek BioStack microplate stacker and BioSpa
Dynamic Range Seven decades
8 automated incubator compatible, and third-party
automation compatible Reading Speed 96 wells, sweep mode: 10 seconds
(Kinetic)
CO2 and O2 Control Range: 0–20% (CO2); 1–19% (O2), with optional gas
(Option) controller Luminescence
Camera Hamamatsu Orca sCMOS, 16-bit grayscale camera, or Light Source Xenon flash
Sony CMOS 16-bit grayscale camera
Detector Photodiode
Objective Capacity Six-position automated turret for user-replaceable objectives
Wavelength Selection Monochromator
Objectives Available Air: 20x, 40x, 60x
Wavelength Range 230–999 nm, 1 nm increments
Water immersion: 40x, 60x
Monochromator 4 nm (230–285 nm), 8 nm (> 285 nm)
Imaging Filter Cubes/ CFP, CY5, DAPI, GFP, RFP, TRITC, brightfield/four user-
Capacity Available replaceable fluorescence cubes Dynamic Range 0–4.0 OD
Laser Six-line Resolution 0.0001 OD
Automated Functions Autofocus, user-trained autofocus, auto-exposure, Pathlength Correction Yes
autoLED intensity
Reading Speed 96 wells: 10 seconds
Autofocus Method Laser autofocus (option), software autofocus (Kinetic)
Positional Controls Software control, joystick controller (option) Reagent Injector Module (Optional)
Image Methods Single-color, multicolor, montage, time-lapse, Z-stacking, Number Two syringe pumps
Z-stack montage
Supported Labware 6- to 384-well plates, Petri and cell culture dishes
Image Collection Rate Laser autofocus, 0 millisecond delay, 96 wells: 8 minutes,
9 seconds Dead Volume 1.1 mL, with backflush
Cytation 7 offers modular and upgradable imaging and detection modes. Imaging opens up a
range of applications for cell-based assays that cannot be performed on a standard plate reader.
Information on cell morphology, localization of signal, cell count and more is obtained with the
Cytation 7 imaging mode.
The inverted microscope module enables fluorescence, brightfield, and color brightfield from 1.25x
to 60x, to analyze both large objects and intracellular details. The upright microscope offers both
reflected and transmitted light imaging for applications including ELISpot, colony counting, material
inspection, and much more.
Save time and computer memory by using multimode detection to identify wells of interest, then
image only those wells.
ELISpot imaging
The upright imaging module automates assays such as ELISpot, in which cell secretions are
rendered visible through the use of a colorimetric reaction. Cytation 7 fully automates image
acquisition, processing, image analysis, and object count.
Cytation 7 and Gen5 software facilitate ROI identification, by scanning samples at low magnification
before prompting the user to identify regions of interest to be imaged at high magnification. This
greatly accelerates the process of imaging ROls in batches of complex microscopic samples.
The plate reader optics use a quad monochromator design with variable bandwidths between 9 and
50 nm. Large bandwidth settings provide increased sensitivity and lower limits of detection. Small
bandwidth settings provide increased specificity when multiple signals are present, which reduces
signal crosstalk and enhances assay performance.
Turn your Cytation 7 into a microvolume analysis system with Agilent BioTek Take3 microvolume
plates. You can run 16 or 48 samples in one run to save a lot of time compared to single-sample
devices. Gen5 is preprogrammed for ssDNA, dsDNA, RNA, and protein quantification in 2 µL.
Technical details
General Image Collection Rate Entire 100 mm dish at 1x: ≤ 2:40 minutes
Entire microscope slide at 1x: ≤ 1:15 minutes
Detection Modes Fluorescence, luminescence, UV-Vis absorbance 96-well ELISpot plate at 1x: ≤ 5 minutes
Read Methods Kinetic, spectral scanning, well area-scanning Fluorescence Intensity
Microplate Types Monochromators: 6- to 384-well plates
Light Source Xenon flash lamp
Imaging: 6- to 1536-well plates
Detector PMT (red-shifted PMT option)
Other Labware Microscope slides, Petri and cell culture dishes, cell culture
Supported flasks (T25), counting chambers (hemocytometers). Agilent Wavelength Selection Quad monochromators (top/bottom)
BioTek Take3 microvolume plates
Wavelength Range 250–700 nm (900 nm option)
Temperature Control 4-Zone Incubation to 45 °C with Condensation Control
Monochromator Variable, from 9–50 nm in 1 nm increments
Cooling Optional Peltier cooling module maintains internal
Dynamic Range Seven decades
temperature with < 1 °C rise over ambient. Provides internal
cooling after incubated processes Sensitivity (Sodium Fluorescein 2.5 pM (0.25 fmol/well, 384-well plate)–top
Fluorescein) Fluorescein 4 pM (0.4 fmol/well, 384-well plate)–bottom
Shaking Linear, orbital, double-orbital
Software Agilent BioTek microplate reader and imager software included Reading Speed (Kinetic) 96 wells: 11 seconds
Agilent BioTek Gen5 Secure enables 21 CFR Part 11 384 wells: 22 seconds
compliance (option) Luminescence
Agilent BioTek Image+ and Image Prime software available for
full image analysis (option) Light Source 300–700 nm
Automation Agilent BioTek BioStack microplate stacker and third-party Detector > 6 decades
automation compatible Wavelength Selection 20 amol ATP (flash)
Agilent BioTek BioSpa 8 automated incubator compatible
Agilent BenchCel microplate handler Absorbance
CO2 and O2 Control Range: 0–20% (CO2); 1–19% (O2) Light Source Xenon flash
(Option) Detector Photodiode
Imaging System: Inverted Microscope Wavelength Selection Monochromator
Imaging Modes Fluorescence, color brightfield, user-selectable brightfield/ Wavelength Range 230–999 nm, 1 nm increments
high-contrast brightfield
Monochromator 4 nm (230–285 nm), 8 nm (> 285 nm)
Imaging Methods Single-color, multicolor, time lapse, montage, Z-stacking,
Z-stack montage Dynamic Range 0–4.0 OD
Image Processing Z-projection, digital phase contrast, stitching Dimensions 20.2” D x 16.4” W x 17.5” H
(51.4 x 41.6 x 44.5 cm)
Camera Sony CMOS, 16-bit; WFOV
Weight 80 lb (36.3 kg)
Lenses Finder scope, 2x, 4x, 8x
Positional Controls Software control, joystick controller (option) 15
Imaging and Microscopy
The imaging capability of Cytation 5 opens up a range of applications for cell-based assays that
cannot be performed on a standard plate reader. Information on cell morphology, localization of
signal, cell count and more is easily obtained with Cytation 5.
With its combination of hybrid plate reader and advanced microscopy mode, Cytation 5 can
transform your lab and increase your productivity.
Cytation 5 automates many traditionally manual microscopy tasks, from slide scanning to time-
lapse live cell assays. Low to high magnification enables powerful image capture for a variety of
biologies. CO2/O2 and temperature control enable time-lapse live cell imaging.
Save time and computer memory by using multimode detection to identify wells of interest, then
image only those wells.
With Gen5 software you can preprogram analysis tasks and walk away. Extensive image
processing includes stitching, Z-projection, deconvolution, and digital phase contrast. Image
analysis includes cell count, confluence, cytoplasm analysis, intracellular analysis, subpopulation
analysis, signal translocation and more.
With its combination of monochromator and filter optics, Cytation 5 is an advanced plate reader
that delivers both the flexibility and performance you need for UV-Vis absorbance, fluorescence,
luminescence, fluorescence polarization, time-resolved fluorescence, and laser-based Alpha
detection.
Cytation 5 uses a quad monochromator with variable bandwidth, which can be set between 9
and 50 nm in 1 nm increments. Large bandwidths provide increased sensitivity and lower limits
of detection. Small bandwidths provide increased specificity when multiple signals are present,
reducing signal crosstalk and enhancing assay performance.
Technical details
General Sensitivity (Sodium Fluorescein 2.5 pM (0.25 fmol/well, 384-well plate)–top
Fluorescein) Fluorescein 4 pM (0.4 fmol/well, 384-well plate)–bottom
Detection Modes UV-Vis absorbance
Fluorescence intensity Reading Speed (Kinetic) 96 wells: 11 seconds
Luminescence 384 wells: 22 seconds
Fluorescence polarization
Time-resolved fluorescence Luminescence
Alpha detection
Wavelength Range 300–700 nm
Read Methods End-point, kinetic, spectral scanning, well-area scanning
Dynamic Range > 6 decades
Microplate Types Monochromator: 6- to 384-well plates
Filters: 6- to 1536-well plates Sensitivity Monos: 20 amol ATP (flash)
Imaging: 6- to 1536-well plates Filters: 10 amol ATP (flash), 100 amol (glow)
Other Labware Microscope slides, Petri and cell culture dishes, cell culture Fluorescence Polarization
flasks (T25), counting chambers (hemocytometer)
Agilent BioTek Take3 microvolume plates Wavelength Selection Filters
Temperature Control 4-Zone Incubation to 65 °C with Condensation Control Wavelength Range 280–700 nm (850 nm option)
Cooling Optional Peltier cooling module maintains internal Sensitivity 1.2 mP standard deviation at 1 nm fluorescence
temperature with < 1 °C rise over ambient. Provides cooling Time-Resolved Fluorescence
after incubated processes.
Wavelength Selection Quad monochromators (secondary mode)
Shaking Linear, orbital, double-orbital
Filters (top)
Software Agilent BioTek microplate reader and imager software
included Agilent BioTek Gen5 Secure enables 21 CFR Part 11 Wavelength Range Filters: 200–700 nm (850 nm option)
compliance (option). Agilent BioTek Gen5 Image+ and Image Sensitivity Filters: europium 40 fM (4 amol/well, 384-well plate)
Prime software available for full image analysis (option) Monos: europium 1200 fM (120 amol/well, 384-well plate)
Automation Agilent BioTek BioStack microplate stacker and third-party
Absorbance
automation compatible. Agilent BioTek BioSpa 8 automated
incubator compatible. Agilent BenchCel microplate handler Wavelength Selection Monochromator
compatible
Wavelength Range 230–999 nm, 1 nm increments
CO2 and O2 Control 0–20% CO2 control and 1–19% O2 control, with optional gas
controller Monochromator 4 nm (230–285 nm), 8 nm (> 285 nm)
Light Source Fluorescence and absorbance: xenon flash lamps Dynamic Range 0–4.0 OD
Alpha detection: 100 mW 680 nm laser
Imaging: high-power LEDs Resolution 0.0001 OD
The microscopy module in Cytation 1 offers 1.25x to 60x magnification to capture large regions of
interest or intracellular details in slides, microplates, cell culture dishes, and other labware. Four color
channels, plus high-contrast brightfield mode, enable fixed and live cell imaging applications, including
label-free cell counting, 3D cell culture, and phenotypic assays. Temperature and CO2/O2 control support
kinetic live cell imaging
Augmented Microscopy
Gen5 software automates image capture, processing, and analysis steps to help create publication-
ready images and data. Augmented Microscopy facilitates these workflows in Gen5, efficiently
guiding scientists through the entire process without requiring extensive training.
The Peltier cooling module ensures environmental stability inside Cytation 1, maintaining internal
temperature with less than a 1 °C rise over ambient during normal operation for uncompromised assay
integrity. The module also accelerates cooling three times faster than typical, rapidly returning the
system to ambient temperature after incubated workflows.
Affordable automation
The automated stage positioning, autofocus, auto-exposure and autoLED intensity bring efficiency to
common microscopy tasks. Cytation 1 integrates with BioSpa 8 automated incubator to automate long-
term, kinetic live cell imaging workflows for up to eight microplates. Agilent BioTek BioStack microplate
stacker can process up to 50 lidded or unlidded plates at a time to automate imaging or multimode
detection processes.
Multimode versatility
Cytation 1 uses filter-based optics for excellent sensitivity in multimode measurements. The
monochromator-based absorbance optics offer a 200 to 999 nm wavelength range, enabling
applications from nucleic acid quantification to turbidimetric measurements. Shaking and reagent
injectors expand applications to kinetics and fast inject/read protocols.
18
Imaging and Microscopy
Technical details
General Absorbance
Detection Modes UV-Vis absorbance Wavelength Selection Monochromator
Fluorescence intensity
Wavelength Range 200–999 nm, in 1 nm increments
Luminescence
Fluorescence polarization Monochromator Bandwidth 2.4 nm
Time-resolved fluorescence
Optical Density Accuracy: < 1% at 2.0 OD; < 3% at 3.0 OD
Read Methods End-point, kinetic, spectral scanning, well-area scanning Linearity: < 1% from 0 to 3.0 OD
Repeatability: < 0.5% at 2.0 OD
Microplate Types Monochromator: 6- to 384-well plates
Stray light: 0.03% at 230 nm
Filters: 6- to 1536-well plates
Imaging: 6- to 1536-well plates Reading Speed (Kinetic) 96 wells: 11 seconds, 384 wells: 22 seconds
Other Labware Microscope slides, Petri and cell culture dishes, cell Fluorescence Intensity
culture flasks (T25), counting chambers (hemocytometer)
Wavelength Selection Deep blocking band pass filters/dichroic mirrors
Agilent BioTek Take3 microvolume plates
Wavelength Range Filters: 200–700 nm (900 nm option)
Temperature Control 4-Zone Incubation to 45 °C with Condensation Control
Dynamic Range Seven decades
Cooling Optional Peltier cooling module maintains internal
temperature with < 1 ºC rise over ambient. Provides Reading Speed 96 wells: 11 seconds, 384 wells: 22 seconds
cooling after incubated processes
Luminescence
Shaking Linear, orbital, double-orbital
Wavelength Range 300–700 nm
Software Agilent BioTek Gen5 software for imaging and
Dynamic Range > 6 decades
microscopy included
Agilent BioTek Gen5 Secure software enables 21 CFR Sensitivity 10 amol ATP (flash), 100 amol (glow)
Part 11 compliance (option) Fluorescein: 0.25 pM (0.025 fmol/well, 384-well plate)
Agilent BioTek Image+ and Image Prime software
Fluorescence Polarization
available for full image analysis (option)
Wavelength Selection Filters
Automation Agilent BioTek BioStack microplate stacker and third-party
automation compatible Wavelength Range 280–700 nm (850 nm option)
Agilent BioTek BioSpa 8 automated incubator
Sensitivity 1.2 mP standard deviation at 1 nm fluorescein
Agilent Benchcel microplate handler compatible
Time-Resolved Fluorescence
CO2 and O2 Control 0–20% CO2 control and 1–19% O2 control, with
optional gas controller Wavelength Selection Filters
Light Source Fluorescence and absorbance: xenon flash lamps Wavelength Range 200–700 nm (850 nm option)
Imaging: high-power LEDs
Sensitivity Europium 40 fM (4 amol/well, 384-well plate)
Detector Fluorescence and luminescence: PMTs
Absorbance: photodiode Reagent Injectors
19
Imaging and Microscopy
Capture the level of detail you need, from whole-well montage, to intracellular detail, with 1.25x to
60x objectives available. The automated, six-position turret makes it simple to capture multiple
magnifications in a single workflow.
Environmental controls
Successful long-term live cell assays rely on a controlled environment to keep cells healthy and
aid proliferation. BioSpa has integrated temperature and CO2/O2 control and monitoring, plus
humidity monitoring to protect cells during kinetic runs that last days or weeks.
Gen5 software has powerful Z-stacking capabilities to capture the important details of a 3D cell
structure. Z-projection and image analysis provides in-depth information about the spheroid.
Z-stacking montage capability brings powerful processing for 3D biologies.
Powerful tools like nuclear and cytoplasmic masking define critical, information-rich regions of
interest for automated, detailed cellular analysis.
20
Imaging and Microscopy
Technical details
General
Microplate Types 6- to 1536-well standard height microplates, with or without lids
Plate height range: 7.6–25.4 mm
Lidded Plate Handling Automated plate movement, including delidding and relidding between the incubator and imager
Software Agilent BioTek BioSpa On-Demand mode for simplified, intuitive workflows for single or multiple users
Agilent BioTek BioSpa Session mode for all imaging, detection, and liquid handling operations
Humidity Control rH: 80–95% (lidded plates and 5% CO2); removable water pan with low level alert
Imaging System
Imaging Mode Confocal, fluorescence, brightfield, high-contrast brightfield, color brightfield and phase contrast
Camera 16-bit gray scale Sony, Hamamatsu Orca sCMOS 16-bit grayscale camera (Agilent BioTek Cytation C10 confocal imaging reader only)
Image Filter Cube Capacity Four user-replaceable fluorescence cubes, plus brightfield channel
Imaging Filter Cubes Available More than 20 colors are available for fluorescence imaging
21
Imaging and Microscopy
General
Slides, cell culture dishes, Slides, cell culture dishes, Slides, cell culture dishes,
Other Labware flasks (T75), hemocytometers, flasks (T75), hemocytometers, flasks (T75), hemocytometers,
chamber slides chamber slides chamber slides
Labware Capacity 1 1 1
Incubation To 40 °C To 45 °C
Automation Compatible •
Upright Microscope
Objectives
Capacity 6 6 6
Air Objectives 1.25x, 2.5x, 4x, 10x, 20x, 40x, 60x 1.25x, 2.5x, 4x, 10x, 20x, 40x, 60x 1.25x, 2.5x, 4x, 10x, 20x, 40x, 60x
Phase Objectives 4x, 10x, 20x, 40x 4x, 10x, 20x, 40x 4x, 10x, 20x, 40x
Widefield Fluorescence • • •
Confocal Fluorescence •
Brightfield • • •
High-Contrast Brightfield • • •
Color Brightfield • • •
Phase Contrast • • •
Z-stacking • • •
Montage • • •
Cell Counting • • •
Z-projection* • • •
Image Stitching* • • •
22
Imaging and Microscopy
Slides, cell culture dishes, Slides, cell culture dishes, Slides, cell culture dishes, Slides, cell culture dishes,
flasks (T75), hemocytometers, flasks (T75), hemocytometers, flasks (T75), hemocytometers, hemocytometers,
chamber slides chamber slides chamber slides chamber slides
1 1 1 8
To 45 °C To 65 °C To 45 °C To 45 °C
• • •
• • • •
• • •
• • • •
• • • •
6 6 2 6
1.25x, 2.5x, 4x, 10x, 20x, 40x, 60x 1.25x, 2.5x, 4x, 10x, 20x, 40x, 60x 1.25x, 2.5x, 4x, 10x, 20x, 40x, 60x 1.25x, 2.5x, 4x, 10x, 20x, 40x, 60x
4x, 10x, 20x, 40x 4x, 10x, 20x, 40x 4x, 10x, 20x, 40x 4x, 10x, 20x, 40x
• • • •
• • •
• • •
• • •
• •
• • • •
• • • •
• • • •
• • • •
• • • •
• • • •
23
Imaging and Microscopy
Image capture
Gen5 captures images from fixed and live cell assays, tissues, whole biology, and more. From
large regions of interest to subcellular and intracellular details, Gen5 captures images in a batch,
endpoint, time-lapse sequence, and Z-stacks. Fluorescence, brightfield, color brightfield, or phase
contrast modes enable diverse applications.
Process
Brightness and contrast adjustments, background flattening, and deconvolution are a few of the
many image preprocessing steps available in Gen5. Z-stacks can automatically be Z-projected, and
digital phase contrast improves the appearance of challenging images. The processing steps in
Gen5 allow you to work within one software package, without requiring extensive training.
Analyze
Gen5 analyzes cellular features such as intensity or morphology (size, perimeter, circularity),
enabling applications such as transfection efficiency, nuclear translocation, or cell cycle assays,
where multiple cell subpopulations are present in the samples. Label-free confluence and cell
counts are accomplished with the unique high-contrast brightfield mode. The add-on spot counting
module enables detailed analysis of intracellular activity.
Publish
During or after image analysis, integrated tools enable convenient annotation of important
information in each image, without having to export to a third-party software package. The built-
in movie maker turns time-lapse images into movies with a click of the mouse. Not only does
Gen5 provide amazing visualization of your samples, it provides quantitative data and results
from the entire experiment. Heat maps, dose-response curves, and multimode and image-based
quantitative data can be combined to rapidly obtain, analyze, and acquire both phenotypic and
quantitative results.
Key features
Powerful instrument control Image and data analysis tools
– User-trained autofocus, image-based, and laser autofocus – Automated cell counting and confluence;
– Automatic camera gain, exposure, and LED intensity settings label-free cell counting
– End-point, montage, Z-stack, and time-lapse imaging modes – Spot counting for intracellular detail analysis
Image preprocessing tools – Primary and secondary masks; nucleus, cytoplasm, or
– Image deconvolution for improved visualization whole-cell analysis
– Automated flattening, smoothing, background correction – Subpopulation analysis and image statistics
– Image stitching, Z-projection – EC50, standard curves, kinetic analysis and more
The Agilent BioTek Gen5 object tracking module enables tracking of the movement of
individual cells throughout the extent of a kinetic experiment. Metrics such as velocity,
distance traveled, and direction are automatically calculated. These metrics are critical
for multiple assay procedures, including those that analyze chemotaxis, which are
The automatic region-of-interest (AutoROI) module incorporates a three-step process
performed within the fields of cancer research, neuroscience, cardiovascular research,
to quickly identify and image ROIs on a microscope slide or other vessel. First, a low-
and others.
magnification imaging step is performed to quickly image the entire area where ROIs
may be located. Second, using previously optimized criteria, ROIs are automatically
identified. Finally, immediately following identification, high-magnification imaging is
automatically performed on the identified areas. This process enables walk-away slide
scanning for four or more slides, if combined with Agilent’s automation offerings.
Primary mask
Secondary mask
Agilent BioTek Gen5 microplate reader and imager software has a highly visual Cells treated with 0.3 µM Taxol; nuclear fragmentation visible (cells highlighted).
interface to facilitate imaging workflows.
Spot counting: intracellular details. Confluence determination: high-contrast BPAE cells at 100x. Zebrafish embryo at 2x, Z-stacked and
brightfield. Z-projected in brightfield.
Dictydium sporotheca, 4x montage 3T3 cells at 4x, digital phase contrast. Fibroblasts expressing RFP and U-87 cell U-87 fibroblast tumoroid at 4x, 4 x 4
in color brightfield, Z-stacked and expressing GFP, just after scratch wound montage, Z-stacked and stitched.
Z-projected. creation. 25
Detection
Hybrid Technology
Some workflows benefit from the flexibility of monochromator-based optical systems; there is no
need to purchase multiple filters, and when the spectral peaks from a fluorophore are unknown,
monochromators can scan to find the ideal excitation and emission peaks. Other assays require the
high sensitivity found in filter-based optical systems. Hybrid Technology offers both major benefits
in a single platform, so there is no compromise of performance or flexibility.
The Synergy Neo2 uses quad monochromators, which have variable bandwidths for excitation and
emission. Selectable from 3 to 50 nm in 1 nm increments, these continuously variable bandwidths
help optimize detection of some fluorophores. Detection parameters for complex multiplexed
assays, such as FRET and SNPs, can be fine tuned for the highest signal with the lowest crosstalk,
and the results you expect.
High throughput is not just about fast plate reading; a high-throughput multimode reader should
handle common and complex assays with equally high performance, even in 1536-well plates.
Synergy Neo2 has a TRF laser to provide the fastest measurements with excellent sensitivity for
critical screening applications like TRF and TR-FRET. Laser-based excitation ensures the best
performance for Alpha assays. The available BioStack microplate stacker provides walk-away
automation of multiple plate processes.
Along with incubation to 70 °C and shaking, Synergy Neo2 can be equipped with a
CO2/O2 controller to provide the ideal environment for robust live cell assays. Direct bottom
detection provides ultrasensitivity for measuring cell-based fluorescence intensity. To automate
live cell workflows, Synergy Neo2 integrates with the BenchCel microplate handler and BioSpa 8
automated incubator.
26
Detection
Technical details
General Reading Speed (Kinetic) 96 well: 6 seconds
384 well: 11 seconds
Detection Modes UV-Vis absorbance
1536 well: 25 seconds
Fluorescence intensity
Luminescence Luminescence
Fluorescence polarization
Time-resolved fluorescence Wavelength Range 300–700 nm
Alpha detection
Dynamic Range > 6 decades
Read Methods End-point, kinetic, spectral scanning, well-area scanning
Sensitivity 5 amol ATP (384-well low-volume plate)
Microplate Types 6- to 1536-well plates
Fluorescence Polarization
Other Labware Petri and cell culture dishes
Agilent BioTek Take3 microvolume plates Light Source Xenon flash
Temperature Control Four-Zone Incubation to 70 °C Detector Dual PMT or single PMT (option)
with Condensation Control Wavelength Selection Filters
Shaking Linear, orbital, double-orbital Wavelength Range 280–700 nm (850 nm option)
Software Agilent BioTek Gen6 data analysis software included. Sensitivity 1 mP standard deviation at 1 nM fluorescein
Agilent BioTek Gen5 Secure software for 21 CFR Part (384-well low-volume plate)
11 compliance (option)
Time-Resolved Fluorescence
Automation Agilent BioTek BioStack microplate stacker
and third-party automation compatible Light Source Xenon flash or TRF laser (option)
Agilent BioTek BioSpa 8 automated incubator
Agilent BenchCel microplate handler Detector Dual PMT or single PMT (option)
Wavelength Quad monochromators (top/bottom)
CO2 and O2 Control 0–20% CO2 control and 1–19% O2 control, with
Selection Filters (top/bottom)
optional gas controller
Wavelength Range Monochromators: 250–700 nm (850 nm option)
Barcode Reader 1D and 2D camera-based scanner
Filters: 200–700 nm (850 nm option)
Absorbance
Sensitivity With TRF laser: 5 fM (384-well low-volume plate)
Light Source Xenon flash With xenon flash lamp: 40 fM (384-well low-volume
plate)
Detector Photodiode
Wavelength Selection Monochromator Alpha Detection
Wavelength Range 230–999 nm, in 1 nm increments Light Source 100 mW 680 nm laser
Synergy H1 is an advanced plate reader that delivers both the flexibility and performance you need
for any microplate assay in your lab. Monochromators offer UV-Vis absorbance, fluorescence
intensity, and luminescence; filters enable fluorescence intensity, polarization, time-resolved
fluorescence, and filtered luminescence.
The Synergy H1 modular design allows you to start with what you need now, and add detection
modes, gas control, and dual-reagent injectors as your laboratory’s workflows evolve.
Excitation and emission bandwidths can be set between 9 and 50 nm in 1 nm increments. Large
bandwidths provide increased sensitivity and lower limits of detection. Small bandwidths provide
increased specificity when multiple signals are present, reducing crosstalk and enhancing assay
performance.
Automated Z-focus enables reading height to be precisely adjusted for best performance in all plate
types and all volumes.
The seven log extended dynamic range detects signals with optimal sensitivity from the low and
high ends of the assay range. Other systems can measure only small portions of the dynamic range
of Synergy H1 using preset gains; this can cause reduced sensitivity on the low end or saturated
signals on the high end of the assay signal range.
Temperature control to 70 °C, Condensation Control, CO2/O2 control and shaking create the ideal
environment for live cell assay workflows. A consistent environment leads to consistent data for
long-term kinetic assays.
The robust, precise dual syringe eliminates the need for regular tubing replacement required by
some peristaltic pump injector designs. There are two available tip types: straight tips enable
vigorous mixing for rapid inject/read assays, and angled tips will not disturb cell layers for
applications such as calcium kinetics.
28
Detection
Technical details
General Monochromator Bandwidth Variable: from 9–50 nm in 1 nm increments (“M2”
configurations)
Detection Modes UV-Vis absorbance
Fixed: 16 nm
Fluorescence intensity
Luminescence Dynamic Range Seven decades
Fluorescence polarization
Sensitivity (Fluorescein) Filters:
Time-resolved fluorescence
0.25 pM (0.025 fmol/well, 384-well plate)
Read Methods End-point, kinetic, spectral scanning, well-area scanning Quad monochromator:
2.5 pM (0.25 fmol/well, 384-well plate)–top
Microplate Types 6- to 384-well plates
4 pM (0.4 fmol/well, 384-well plate)–bottom
Other Labware Petri and cell culture dishes
Reading Speed (Kinetic) 96 well: 11 seconds
Agilent BioTek Take3 microvolume plates
384 well: 22 seconds
Temperature Control 4-Zone Incubation to 70 °C (“M2” configurations) or to
Luminescence
45 °C (all other configurations)
Sensitivity Monochromators: 20 amol ATP
Shaking Linear, orbital, double-orbital
Filters: 10 amol ATP
Software Agilent BioTek Gen6 data analysis software included
Fluorescence polarization
Agilent BioTek Gen5 Secure software enables 21 CFR
Part 11 compliance (option) Light Source Xenon flash
Automation Agilent BioTek BioStack microplate stacker and third-party Detector PMT
automation compatible
Wavelength Selection Filters
Agilent BioTek BioSpa 8 automated incubator compatible
Wavelength Range Excitation range: 330–700 nm
CO2 and O2 Control 0–20% CO2 control and 1–19% O2 control, with Emission range: 400–700 nm
optional gas controller
Sensitivity 2 mP standard deviation at 1 nm fluorescein
Absorbance
Time-resolved Fluorescence
Light Source Xenon flash
Light Source Xenon flash
Detector Photodiode
Detector PMT
Wavelength Selection Monochromator
Wavelength Filters (top)
Wavelength Range 230–999 nm, in 1 nm increments Selection
Monochromator 4 nm (230–285 nm); 8 nm (> 285 nm) Sensitivity < 40 fM
Bandwidth
Reagent Injectors
Dynamic Range 0–4.0 OD
Number Two syringe pumps
Resolution 0.0001 OD
Supported Labware 6- to 384-well plates, Petri dishes
Pathlength Correction Yes
Dead Volume 1.1 mL with backflush
OD Accuracy < 1% at 2.0 OD
< 3% at 3.0 OD Dispense Volume 5–1,000 µL in 1 µL increments
Detector PMT
Wavelength Selection Quad monochromators (top/bottom)
Filters (top)
Wavelength Range Monochromators: 250–700 nm (900 nm option)
29
Detection
The Synergy HTX is the ideal instrument for nucleic acid and protein quantification, enzyme
assays, biomarker quantification, and ELISA assays, as well as cell-based assays (gene
expression, cellular growth, cytotoxicity).
AlphaScreen/AlphaLISA
AlphaScreen and AlphaLISA assays can be performed on Synergy HTX with excellent results.
Alpha-capable configurations add assay versatility to basic research requirements.
Two excitation and two emission filters are included with the reader, and can be used for top and
bottom reading. Bottom reading is usually recommended when working with adherent cells, as it
often provides better signal-to-background ratios. Top reading is typically best for assays where
the fluorescence signal comes from the solution.
All Synergy readers use monochromators for absorbance detection. This provides unlimited
wavelength selection from the low UV to the near infrared, in 1 nm increments, and enables
spectral scanning.
The Synergy HTX can automate glow and flash luminescence assays, thanks to its optional dual-
reagent injector module. Typical assays include ATP quantification as well as luciferase gene
expression assays.
30
Detection
Technical details
General Luminescence
Detection Modes UV-Vis absorbance Wavelength Range 300–700 nm
Fluorescence intensity
Dynamic Range > 6 decades
Luminescence
Time-resolved fluorescence (secondary mode) Sensitivity 10 amol ATP (flash)–Lum and Abs/Lum configurations
Alpha detection 30 amol ATP (flash)–Multimode configurations
Read Methods End-point, kinetic, spectral scanning, well-area scanning Time-Resolved Fluorescence
Microplate Types 6- to 384-well plates Light Source Xenon flash
Other Labware PCR plates, Petri and cell culture dishes Detector PMT
Agilent BioTek Take3 microvolume plates
Wavelength Selection Monochromator
Temperature Control 4-Zone Incubation to 50 °C
Alpha Detection
with Condensation Control
Shaking Linear, orbital Light Source Tungsten halogen
Software Agilent BioTek Gen6 data analysis software included Detector PMT
Agilent BioTek Gen5 Secure enables 21 CFR Part 11 Wavelength Selection Filters
compliance (option)
Sensitivity 300 amol bio-LCK-P, 25 µL/well in 384-well plate
Automation Agilent BioTek BioStack microplate stacker and third-party
automation Read Speed 96 well: 2 minutes
31
Detection
At about half the price of similar instruments, Synergy LX is the solution for labs looking for
an easy-to-use microplate reader for UV-Vis, fluorescence, and luminescence assays. The
independent optical paths use high-quality components, ensuring uncompromised performance
in all detection modes.
Common assays
Microvolume quantification
Use the Take3 microvolume plate with Synergy LX for fast and easy nucleic acid and protein
determinations. Preprogrammed protocols in Synergy LX display immediate results for up to
sixteen 2 µL samples. Output results to a USB drive for use in downstream workflows.
Easy operation
With its large color touch screen, Synergy LX makes it simple to select and run a protocol.
The data is displayed immediately after the measurement with a color gradient to help quickly
visualize the data range.
32
Detection
Technical details
General Fluorescence Intensity
Detection Modes UV-Vis absorbance Light Source Halogen
Fluorescence intensity
Detector PMT
Luminescence
Wavelength Selection Bandpass filters
Read Methods End-point (onboard software)
End-point, kinetic, area scanning, absorbance spectral Wavelength Range 320–700 nm (low-noise PMT)
scanning (under Agilent BioTek Gen6 software control) 320–850 nm (red-shifted PMT)
Microplate Types UV-Vis absorbance: 6- to 384-well plates (onboard Dynamic Range > 6 decades
software)
Sensitivity 2 pM fluorescein
Fluorescence intensity and luminescence: 96- and 384-
well (onboard software) Reading Speed (Kinetic*) 96 wells: 24 seconds
All modes: 6- to 384-well microplates 384 wells: 76 seconds
(under Agilent BioTek Gen6 software control) (*under Agilent BioTek Gen6 software control)
Light Source Xenon flash Dimensions 15” W x 15” D x 15” H (with touch screen)
(38.1 x 38.1 x 38.1 cm)
Detector Photodiode
15” W x 15” D x 12” H
Wavelength Selection Monochromator (38.1 x 38.1 x 30.5 cm)
33
Detection
Agilent BioTek Synergy Neo2 hybrid multimode reader and Gen6 data analysis software.
35
Detection
General
Monochromator: 6- to 384-well
Microplate Types 6- to 1536-well
Filter and imaging: 6- to 1536-well
BenchCel Compatible • •
BioSpa 8 Compatible • •
BioStack Compatible/Automation-Ready • •
Take3 Compatible • •
Condensation Control • •
Monochromator-Based UV-Vis
• •
Absorbance
Monochromator-Based Fluorescence • •
Variable-Bandwidth Fluorescence
• Cytation 7, Cytation 5
Monochromator
Luminescence • •
TRF Laser •
Upgradable to Imaging •
36
Detection
Onboard software
Absorbance: 6- to 384-well
6- to 384-well 6- to 384-well FI and LUM: 96- and 384-well
Under Agilent BioTek Gen6 software control
All modes: 6- to 384-well
• •
• •
• • •
To 70 ºC (“M2” configurations)
To 50 ºC
To 45 ºC
• •
• • •
• • •
• • •
• • •
• (Secondary mode)
37
Detection
UV-Vis measurements
The monochromator-based optics offer wavelength selection from 200 to 999 nm, for applications
from nucleic acid quantification to ELISA, without using filters. Epoch 2 can measure up to forty-
eight 2 µL samples in the unique Take3 microvolume plates, for rapid, direct quantification. An
optional cuvette port provides 1 cm measurements, making Epoch 2 a versatile spectrophotometer
for multiple applications.
The color touch screen enables easy program creation and selection for a wide range of end-
point and kinetic assays. The quick read function provides the fastest read-to-results. Select from
predefined programs or create new programs for basic data analysis. Use the convenient flash
drive or available printer for data output. Available 6 data analysis software enables computer
control of all Epoch 2 read modes, including well-area scanning and expanded data analysis
capabilities. When controlled by Gen6, Epoch 2 is automation compatible.
Epoch 2 features Agilent BioTek 4-Zone Incubation up to 65 °C, with minimal variation across the
plate; ideal for a wide range of temperature-sensitive assays. The Condensation Control feature
solves the common problem of condensation buildup on plate lids during incubated kinetic runs.
Epoch 2 can be integrated with the BenchCel microplate handler or BioSpa 8 automated incubator
for unattended automation.
38
Detection
Technical details
General
Other Labware Agilent BioTek Take3 microvolume plates, standard cuvettes (option)
Onboard Software Protocol creation including end-point and kinetic reading parameters, basic data analysis, reporting, and exporting
Detector Photodiode
Resolution 0.0001 OD
Dimensions With touch screen: 12.5” W x 15.5” D x 13” H (31.8 x 39.3 x 33 cm)
Without touch screen: 12.5” W x 15.5” D x 8” H (31.8 x 39.3 x 20.3 cm)
Weight With touch screen: 25 lb (11.3 kg)
Without touch screen: 20 lb (9.1 kg)
39
Detection
ELISA assays, Epoch is ideally suited to the life science laboratory, where Microplate Types 6- to 384-well plates
application flexibility is required. Other Labware Agilent BioTek Take3 microvolume plates
Microplate reading for 6- to 384-well plates Software Agilent BioTek Gen6 data analysis software included
Agilent BioTek Gen5 Secure software enables
The Epoch optical and mechanical systems are designed to provide 21 CFR Part 11 compliance (option)
optimal measurements in a variety of microplates. The area scanning
Automation Agilent BioTek BioStack microplate stacker and third-
capability provides multiple measurements across larger diameter wells, party automation compatible (“R” model)
resulting in more meaningful data analysis. Absorbance
Take3 microvolume plate compatible Light Source Xenon flash
When sample size matters, as in critical nucleic acid and protein Detector Photodiode
quantification, the Take3 microvolume plate provides up to sixteen 2 µL Wavelength Selection Monochromator
measurements, without needing to dilute important samples. Wavelength Range 200–999 nm, in 1 nm increments
End-point, kinetic, spectral scanning Monochromator 5 nm
Bandwidth
There is no need to buy expensive instrumentation to perform a variety
Dynamic Range 0–4.0 OD
of absorbance measurements. Epoch, driven by Gen6 software, is a high-
value system with maximum assay flexibility. Resolution 0.0001 OD
Pathlength correction Yes
Monochromator ± 2 nm
Wavelength Accuracy
Monochromator Wavelength ± 0.2 nm
Repeatability
40
Detection
Use the Agilent BioTek Take3 microvolume plate with your Cytation,
Synergy, or Epoch reader to rapidly and easily measure multiple 2 µL
samples for direct DNA, RNA, and protein quantification.
Technical Details
Take3 Take3 Trio
2 µL Sample Capacity 16 48
41
Detection
The 800 TS is ideal for a variety of applications including ELISA, protein and other end-point
protocols. Incubation and shaking expand the application range to include enzyme kinetics
and cell-based assays. The 800 TS partners perfectly with the Agilent BioTek 50 TS washer to
automate all your workflows.
The touch screen interface makes protocol creation intuitive and simple. Defined protocols are
saved onboard for convenient, quick selection. The 800 TS reads the plate efficiently, delivering
results quickly and reliably.
Results are displayed immediately after measurement, and can be sent to the optional printer or a
USB flash drive. Import data to Gen6 software for advanced data handling and custom reporting
With the 800 TS, affordability doesn’t mean compromised performance. The high-quality
hardware and optical design ensure results for all assays. As an FDA registered and ISO certified
manufacturer, Agilent BioTek understands the importance of performance and data verification.
Verify and qualify the 800 TS performance over time, using the Agilent BioTek absorbance test
plate and product qualification package.
42
Detection
Technical details
General
Microplate Types 6-, 12-, 24-, 48-, 96-well microplates; 384-well and Terasaki trays (NB configurations)
Temperature Control To 50 °C
Shaking Linear (except NB configurations)
User Interface 4.3” color LCD touch screen display
Onboard Software Up to 40 user-programmable protocols
Software Agilent BioTek Gen6 data analysis software included
Agilent BioTek Gen5 Secure software (option)
Absorbance
43
Detection
LogPhase 600 is a four-plate microplate reader that facilitates microbial growth assays.
The shaking mechanism in LogPhase 600 is specifically designed for microbial growth assays; its
robust shaking ensures that your cells will not settle, even during long-term kinetic assays.
Optimized incubation
Condensation Control
Condensation Control sets a temperature gradient from top to bottom to prevent condensation on
the sealed plates that can cause light scatter and reading artifacts.
LogPhase 600 provides consistent growth conditions that are essential for microbial growth
assays.
The LogPhase 600 app has an easy-to-use interface, with analysis tools designed for microbial
growth researchers. New users can be up and running in minutes, with very little training. Multiplate
data can be viewed on the screen at the same time. The app automatically calculates lag time,
maximum rate (OD/min), and time to stationary phase.
44
Detection
Technical details
General
Software LogPhase app included; provides reader control, data collection, and complete analysis
Absorbance
Resolution 0.001 OD
Power Consumption 24 VDC power supply compatible with 100–240 volts AC at 50–60 Hz, 250 W (minimum)
45
Detection
Key Features
Microplate Capacity 1 1
Temperature Control To 65 °C
Automation Ready/BioStack
• ("R" configuration)
compatible
BenchCel Compatible •
BioSpa 8 Compatible •
Take3 Compatible • •
46
Detection
Filter Filter
560–640 nm
400–750 nm (340–750 nm option)
(configuration dependent)
4 1
0–4.0 0–4.0
To 45 °C To 50 ºC
Orbital Linear
1 5
47
Liquid Handling
The flexibility and capabilities of the 406 FX washer dispenser allow noncontact dispensing as
well as full-plate washing in a variety of plate densities, all in one instrument. This eliminates
the need to move microplates between a plate washer and separate dispensers for many liquid
handling workflows.
Multiple independent fluid paths means that up to six different reagents can be loaded and
dispensed in a single procedure, eliminating the need to incorporate multiple dispensers.
Dual peristaltic pump dispensers and quad syringe pumps enable noncontact dispensing of buffers,
media, cells, and other precious reagents, in volumes ranging from 500 nL to 3,000 μL, with minimal
dead volume.
Automation friendly
Left- and right-side robotic arm accessibility allows the 406 FX to be easily integrated with the
Agilent BioTek BioStack microplate stacker, and Agilent BenchCel microplate handler, and other
third-party automation to increase assay throughput.
Cell-friendly design
The combination of angled dispense tubes, highly adjustable aspiration and dispense rates, and
X- and Y-axis positioning ensure the integrity of cell monolayers during dispensing and wash
procedures.
The built-in Agilent BioTek Ultrasonic Advantage allows the instrument to clean buildup in the
manifold tube automatically, preventing failure during wash procedures.
Available accessories automate magnetic bead-based multiplex assays. Depending on the magnet
type used, beads are pulled to the center or to the edges of the well.
Technical details
General Recommended 1 μL cassette: 1,000 384-well microplates at 5 μL/well
Cassette 5 μL cassette: 1,000 96-well microplates at 50 μL/well
Microplate Types 96-, 384-, and 1536-well
Replacement 10 μL cassette: 1,000 96-well microplates at 100 μL/well
Low profile and standard height
Interval
Onboard Touch Create, edit, or run multiple protocols
Sterilization Autoclave, chemical
Screen
Dispensing—Syringe Pump (Multichannel)
Software (Computer Agilent BioTek Liquid Handling Control (LHC3) software
Control) Agilent BioTek LHC3 Secure software enables 21 CFR Part Manifold Types 96-well dispensing:
11 compliance (option) One 16-tube (2 x 8) manifold—316 SS tubes
96-/384-well dispensing:
Separation Biomagnetic separation (optional)
Two 16-tube (1 x 16) manifolds—316 SS tubes
Shaking Programmable up to 60 minutes 1536-well dispensing:
Slow, medium, fast, or variable Two 32-tube (1 x 32) manifolds—316 SS tubes or sapphire-
jeweled 316 SS tubes
Soaking Programmable up to 60 minutes
Ultrasonic Advantage Standard Fluid Delivery Two positive-displacement syringe drives per syringe pump, up
to two syringe pumps per 406 FX
Automation Agilent BioTek BioStack microplate stacker and third-party
automation compatible Dispensing Speed 20 μL/well, 96 wells, 1 x 16 tubes: 5.25 seconds
Agilent BenchCel microplate handler compatible; requires 20 μL/well, 384 wells, 1 x 16 tubes: 14 seconds
VWorks 13.1.12 or higher 3 μL/well 1536 wells, 2 x 32 tubes: 7 seconds
Volume Range 3−3,000 μL/well, selectable in 1 μL increments
Washing
Minimum prime volume: 12 mL
Manifold Types 96-well washing: 96-tube manifold—straight dispense tubes
Flow Rates User-programmable rates from high to low
96- and 384-well washing: 96-tube Dual-Action manifold—20°
angled dispense tubes Dispense ± 1 μL at 5 μL
384-well washing (fast): 192-tube Dual-Action manifold—7° Accuracy ± 1 μL at 20 μL
angled dispense tubes ± 1% at 100 μL
1536-well washing: two 32-tube dispense manifolds—7°
Dispense ≤ 5% CV at 5 μL
angled dispense tubes
Precision ≤ 2.5% CV at 20 μL
Volume Range 3–3,000 µL/well, in 1 µL increments ≤ 1% CV at 100 μL
Buffer/Reagent Autoswitching module for up to four buffers Sterilization Chemical, autoclavable option
Selection
Physical Characteristics
Supply Bottle 4 or 10 L (optional)
Power 100−240 Volts AC at 50−60 Hz
Waste Bottles 4, 10, and 20 L waste bottles available; direct-to-drain option Consumption
available
Dimensions 12.8” W x 24.1” D x 15.25” H (32.5 x 61 x 39 cm)
Dispense Accuracy ± 3%
Weight 45 lb (20.4 kg)
Dispense Precision ≤ 3% CV (model dependent)
Residual Volume ≤ 2 μL/well
Wash Speed 96 wells, 300 μL/well, 96-tube manifold: 13 seconds
384 wells, 100 μL/well, 192-tube manifold: 17 seconds
1536 wells, 10 μL/wells, two 32-tube manifolds: 36 seconds
Flow Rates High flow to low flow
Optimized rates for cell assays
Sterilization Chemical
Dispensing—Peristaltic Pump
Manifold Types 8-tip (1 x 8) cassette with plastic tubes, 316 stainless steel
(SS) tubes, or sapphire-jeweled 316 SS tubes
Fluid Delivery Up to two peristaltic pumps
Dispense Speed 96 wells, 10 μL/well: 8 seconds
384 wells, 5 μL/well: 12 seconds
1536 wells, 1 μL/well: 27 seconds
Volume Range 500 nL to 3,000 μL/well, selectable in 1 μL increments
Flow Rates User-programmable rates from high to low
Optimized rates for cell assays
49
Liquid Handling
The EL406 integrates 96-, 384-, and 1536-well microplate washing with three dispensers in one
compact instrument. Now you can simply press a button and walk away, or automate an entire
batch by adding a BioStack microplate stacker. For entire workflow automation, the EL406 can be
integrated to the BenchCel microplate handler, or the BioSpa 8 automated incubator along with a
with an Agilent BioTek imager or reader.
The EL406 incorporates the Agilent BioTek Dual-Action manifold for thorough yet gentle washing of
loosely adherent cell layers. Agilent BioTek Ultrasonic Advantage provides integrated ultrasonic
cleaning for the manifold tubes, to automate wash manifold maintenance.
The EL406 eliminates the need to choose a dispensing technology by offering both peristaltic and
syringe pumps on a single platform.
The EL406 automates full microplate washing of magnetic microspheres, which are used in an
increasing number of multiplex assays. Developed in conjunction with Luminex xMAP technology
leaders, Agilent BioTek separation modules incorporate high-energy neodymium iron boron
magnets for speed and efficiency. An available vacuum filtration module makes the EL406 well
suited for polystyrene beads and filtration-to-waste processes.
50
Liquid Handling
Technical details
General Dispense 1 µL cassette:
Performance Recommended volume range: 1–50 µL
Microplate Types 96-, 384-, 1536-well
Dispense accuracy: ± 5% at 1 µL
Low profile and standard height
Dispense precision: ≤ 5% CV at 1 µL
Solid and filter bottom (option)
≤ 10% CV at 500 nL
Onboard Software Create, edit, or run multiple protocols Minimum prime volume: 1.20 mL
5 µL cassette:
Software Agilent BioTek LHC software (option)
Recommended volume range: 5–2500 µL
Agilent BioTek LHC Secure software enables 21 CFR Part 11 Dispense accuracy: ± 2.0% at 5 µL
compliance (option) Dispense precision: ≤ 2.5% CV at 5 µL
SiLA compliant driver (option) Minimum prime volume: 4.23 mL
Separation Biomagnetic separation, vacuum filtration (option) 10 µL cassette:
Recommended volume range: 10–3,000 µL
Shaking Programmable up to 60 minutes Dispense accuracy: ± 2.0% at 10 µL
Slow, medium, fast, or variable Dispense precision: 2.0 CV at 10 µL
Soaking Programmable up to 60 minutes Minimum prime volume: 7.36 mL
Ultrasonic Advantage Yes (standard on most configurations) Recommended 1 µL cassette: one-thousand 384-well microplates at 5 µL/well
Cassette 5 µL cassette: one-thousand 96-well microplates at 50 µL/well
Automation Agilent BioTek BioStack microplate stacker and third- Replacement 10 µL cassette: one-thousand 96-well microplates at 100 µL/well
party automation compatible automation compatible Interval
Agilent BioTek BioSpa 8 automated incubator compatible Sterilization Autoclave, chemical
Washing Dispensing—Syringe Pump (Multichannel)
Manifold Types 96-well washing: 96-tube manifold Manifold Types 96-well dispensing:
96- and 384-well washing: 96-tube Dual-Action manifold One 16-tube (2 x 8) manifold: 316 stainless steel tubes
384-well washing (fast): 192-tube Dual-Action manifold 96-/384-well dispensing:
1536-well washing: Two 32-tube dispense manifolds, 316 SS Two 16-tube (1 x 16) manifolds: 316 stainless steel tubes
tubes or sapphire-jeweled 316 SS tubes 1536-well dispensing:
Volume Range 3–3,000 µL/well, in 1 µL increments Two 32-tube (1 x 32) manifolds: sapphire-jeweled 316 stainless
steel or 316 stainless steel tubes
Wash Cycles 1–250
Dispensing Speed 20 µL/well, 96 wells, 1 x 16 tubes: 5 seconds
Buffer/Reagent Automated buffer switching module for up to four buffers 20 µL/well, 384 wells, 1 x 16 tubes: 14 seconds
Selection (option)
3 µL/well, 1536 wells, 2 x 32 tubes: 7 seconds
Supply Bottle 4 or 10 L (optional) Volume Range 3–3,000 µL/well, selectable in 1 µL increments
Dispense Accuracy ± 3% Minimum prime volume: 12 mL
Dispense Precision < 3% CV (model dependent) Flow Rates User-programmable rates from high to low
51
Liquid Handling
The 405 TS washer incorporates all the features and functionality of the prior Agilent BioTek
ELx405 models, and improves accessibility through its touch screen and extensive onboard
software. 96- and 384-well microplate-based wash procedures are only “two touches” away with
the easy-to-use interface. Additionally, two USB ports provide convenient file transfer, storage, and
operation. A context-sensitive Help system and several instructional videos are also included.
The 405 TS washer makes quick work of any washing assay, and is especially well suited for
integration into automated systems, where the wash process is controlled remotely. The 405 TS
can be integrated with the BioSpa 8 automated incubator for unattended automation of many
common processes.
The 405 TS is available in various models for optimized performance with the most sensitive and
rigorous assay requirements. When the protocol calls for washing loosely adherent cells, angled
dispense tubes, extralow flow rates, and software-adjustable X, Y, and Z positioning enable washing
without cell layer disruption. Magnetic and polystyrene bead washing are effectively accomplished
with the 405 TS.
Agilent BioTek Verify technology runs an automated QC check for manifold tube blockage, and
visually reports any failures. Ultrasonic Advantage can then be used to automatically clean the
manifolds. Together, these features make the 405 TS a self-checking, self-maintaining microplate
washer!
The Agilent BioTek Select deep well washer washes 96- and 384-well plates up to 50 mm tall, and
is also compatible with standard height plates without any hardware or software changes. This
versatile system is optimal for labs working in deep well blocks and standard plates.
52
Liquid Handling
Technical details
General
53
Liquid Handling
Applications for the 50 TS extend beyond simple dispense and aspirate routines typical of many
ELISA processes. Fluid delivery can be optimized for gentle cell-based assay washing, and available
modules automate biomagnetic and vacuum filtration protocols. To automate many lower-
throughput workflows, the 50 TS partners well with the 800 TS microplate absorbance reader.
The 50 TS software includes predefined protocols for quick selection of commonly used wash
parameters. Creating custom protocols onboard the 50 TS is easy: the touch screen interface
makes multistep program creation intuitive and simple. Protocols are saved for quick recall. From
just a single strip to a full microplate, the 50 TS washes quickly, efficiently, and reliably.
Liquid level sensors will alert you to low supply or full waste levels, allowing wash programs to
run safely and reliably. Predefined, automated maintenance routines keep the fluid path clean and
prevent buildup of salt, protein, or other material that can block manifold tubes, causing inadequate
washing. Agilent BioTek understands the importance of performance and data verification:
the 50 TS product qualification package provides simple, straightforward instructions for
verification of the 50 TS performance over time.
54
Liquid Handling
Technical details
General
Microplate Types 96 wells
96 and 384 wells (“16” configurations)
Low profile and standard height
24 wells (with 4-well manifold)
Solid and filter bottom (“V” models)
Filter pore sizes 0.45–1.2 µm
Onboard Software Up to 75 user-programmable protocols
Quick menu
Create or edit custom protocols
Run protocols created onboard or downloaded from Agilent BioTek LHC software
Software Agilent BioTek LHC software, for external computer control and operation (optional)
Separation Biomagnetic separation (“M” configurations)
Vacuum filtration (“F” configurations)
Shaking Programmable in mm:ss up to 30 minutes
Soaking Programmable in mm:ss up to 30 minutes
User Interface 4.3” color LCD touch screen display
Washing
Manifolds Manifold Type Plate Type
4-well manifold 24-well
8-well manifold 96-well
8s-well manifold (short dispense tube) 96-well
2 x 8-well manifold 96-well
12-well manifold 96-well
16-well manifold 96- and 384-well
Volume Range 25–3,000 µL/well
Wash Cycles 1–10
Buffer/Reagent Selection Automated buffer switching module for up to three buffers (“V” configurations)
Dispense Precision Plate Type Manifold Performance
96-well 8- and 8s-well ≤ 3.0% CV when measured over six 300 µL/well dispenses of deionized water with 0.1% Tween 20
96-well 12-well ≤ 3.0% CV when measured over four 300 µL/well dispenses of deionized water with 0.1% Tween 20
384-well 8-, 16-well ≤ 4.0% CV when measured over six 100 µL/well dispenses of deionized water with 0.1% Tween 20
96-well 2 x 8-well ≤ 4.0% CV when measured over six 300 µL/well dispenses (whole plate) of deionized water with 0.1%
Tween 20
24-well 4-well ≤ 4.0% CV when measured over six 1120 µL/well dispenses of deionized water with 0.1% Tween 20
Residual Volume Plates Manifold Performance (Average Residual/Well)
96-well 8-well, 12-well ≤ 2.0 µL/well after 3-cycle wash, 300 µL/well dispensed
96-well 2 x 8-well ≤ 4.0 µL/well after 3-cycle wash, 300 µL/well dispensed
384-well 8-, 16-well ≤ 4.0 µL/well after 1-cycle wash, 100 µL/well dispensed
24-well 4-well ≤ 5.0 µL
96-well filter 8-, 2 x 8-, 12-well < 1.2 g increase after blotting
bottom
Wash Speed 96 wells, 8-tube manifold, > 300 µL/well: < 130 seconds
Fluid Delivery One positive displacement syringe drive
Physical Characteristics
Power Consumption 40 W (maximum)
Dimensions 15’ W x 15” D x 8” H (38.1 x 38.1 x 20.3 cm)
Weight 22 lb (9.9 kg)
55
Liquid Handling
Key Features
96-/384-Well Microplates • • •
1536-Well Microplates • •
24-Well Microplates
Full Microplates • • •
Strip Microplates •
Vacuum Filtration • •
Biomagnetic Separation • •
Dual-Action Manifold • •
Ultrasonic Advantage • •
Verify Technology
BenchCel Compatible • • •
BioSpa 8 Compatible • •
BioStack Compatible • • •
Touch Screen UI • •
56
Liquid Handling
• • • •
• • • •
• • • •
• • • •
• • •
• • •
• • •
• • •
• •
• • • •
• •
• • •
• • • •
57
Liquid Handling
When the liquid handling workflow calls for individual well dispensing along with rapid bulk
dispensing, RAD module provides single-channel dispensing to discrete wells of 6- to 384-well
plates. A custom plate map can be imported for use in concentration normalization protocols.
Wash module
The wash module automates 6- to 384-well plate washing, using a precise syringe-driven
dispense pump. A MultiFlo FX configured with multiple dispensers and the wash module provides
astounding liquid handling versatility.
With the AMX module, MultiFlo FX can meet the needs of important research that uses 3D cell
structures such as spheroids and tumoroids, plus suspension cell-based applications. The AMX
module provides automated, gentle media exchange for these critical workflows.
The MultiFlo FX is configurable and upgradable from dispense or wash only, to a combined dispense
and wash combination, plus AMX or single-channel dispensing with the RAD modules. MultiFlo
FX fits on any lab bench, and is easily integrated with the BenchCel microplate handler, BioSpa 8
automated incubator or BioStack microplate stacker.
58
Liquid Handling
Technical details
General Supply Bottle 1 or 2 L
Microplate Types Dispensing (peristaltic pump and syringe) Sterilization Method Chemical, autoclavable option
96-, 384-, and 1536-well standard, deep and PCR plates; 6-.
Washing
12-, 24,- and 48-well plates (dispense tip configurable)
Washing Wash Volume Range 20–30,000 µL/well
96- and 384-well standard plates; 6-, 12-, 24-, and 48-well
plates (with compatible manifold configuration) Wash Cycles 1–10
Onboard Software Create, edit, or run multiple protocols Wash Speed 96-wells, 8-tube manifold, 3 cycles, 300 µL/well: < 130 seconds
Dispense 1 µL cassette: recommended range: 1–50 µL Other Labware 96-well cluster tubes (minitubes) up to 50 mm height (requires
Performance Accuracy: + 5% at 1 µL Supported custom carrier p/n 7212042)
Precision: < 5% CV at 1 µL
< 10% CV at 500 nL Manifold Types RAD single, with plastic or steel tip with 1, 5, or 10 µL tubing,
Minimum prime volume: 1.20 mL 7° angle
RAD 8-to-1 plastic tip, with 5 µL tubing, angled bulk dispense
5 µL cassette: recommended range: 5–2500 µL chute
Accuracy: + 2.0% at 5 µL
Volume Range 500 nL to 30,000 µL
Precision: < 2.5% CV at 5 µL
Minimum prime volume: 4.23 mL Minimum Prime 1 µL cassette, 18”: 90 µL; 1 µL cassette, 30”: 150 µL
Volume 5 µL cassette, 18”: 320 µL; 1 µL cassette, 30”: 530 µL
10 µL cassette: recommended range: 10–3,000 µL 10 µL cassette, 18”: 555 µL; 10 µL cassette, 30”: 920 µL
Dispense accuracy: + 2.0% at 10 µL
Dispense precision: < 2.0% CV at 10 µL Dispense Speed 1 µL cassette, 1 µL/well: 19 seconds (96 wells), 19 seconds
Minimum prime volume: 7.36 mL (High Flow Rate) (384 wells)
5 µL cassette, 5 µL/well: 19 seconds (96 wells), 58 seconds
Dispensing—Syringe Pump (Multichannel)
(384 wells)
Manifold Types 96- and 384-well dispensing: 10 µL cassette, 10 µL/well: 21seconds (96 wells), 66 seconds
One 16-tube (2 x 8) manifolds: 316 SS tubes (384 wells)
Two 16-tube (1 x 16) manifolds: 316 SS tubes
Dispense 1 µL cassette (medium), 0.5 µL/well: precision 10% CV
1536-well dispensing: Performance 1 µL cassette (medium), > 2 µL/well: accuracy + 5%,
Two 32-tube (1 x 32) manifolds: sapphire-jeweled 316 SS or precision 5% CV
316 SS tubes 5 µL cassette (high), > 10 µL/well: accuracy + 2%,
6- to 48-well dispensing: custom autoclavable manifolds precision 2.5% CV
available 10 µL cassette (high), > 20 µL/well: accuracy + 2%,
precision 2% CV
Fluid Delivery Two positive displacement syringe drives 8-to-1 cassette (high), > 10 µL/well: precision 2.5% CV
Dispense Speed 20 µL/well, 96 wells, 1 x 16 tubes: 5 seconds 8-to-1 cassette (high), > 80 µL/well: accuracy + 2%
20 µL/well, 384 wells, 1 x 16 tubes: 14 seconds Physical Characteristics
3 µL/well, 1536 wells, 2 x 32 tubes: 7 seconds
Power Consumption 90 W (maximum)
Volume Range 3–3,000 µL/well selectable in 1 µL increments
Minimum prime volume: 12 mL Dimensions Base instrument: 17.2" W x 11.8" D x 8" H
(43.7 x 29.9 x 20.3 cm)
Flow Rates User-programmable rates from high to low
Weight Base instrument: 19.5 lb (8.8 kg)
Dispense Accuracy ± 1 µL at 5 µL and 20 µL
± 1% at 100 µL Connectivity Two USB ports: protocol storage/transfer and for optional
external mouse or keyboard
Dispense Precision < 5% CV at 5 µL
< 2.5% CV at 20 µL
< 1% CV at 100 µL 59
Liquid Handling
Low-maintenance design
Guaranteed sterility
The entire fluid path is autoclavable for applications requiring sterility. The MicroFill pump, tubing,
dispense manifold, and supply bottle are quickly changed with no reagent carryover. User-controlled
dispense flow rates allow low- to high-velocity dispensing for both biochemical and cell-based
assays. Low profile, standard, and deep well microplates are all accommodated with a broad
volume range from 5 µL to 6 mL.
Unattended operation
For increased throughput, the MicroFill can be integrated with the BioStack microplate stacker, or
interfaced to third-party automated systems with its available interface software. MicroFill drivers
are available from most of today’s leading system providers.
60
Liquid Handling
Technical details
General
61
Liquid Handling
General
Microplate Types 96, 384, and 1536, standard and low profile 96, 384, and 1536, standard and low profile
Up to two peristaltic dispense pump modules One peristaltic dispense pump module
Modules Available
Up to two dual syringe pump modules One dual syringe pump module
Dispense Technology Peristaltic pump, syringe pump Peristaltic pump, syringe pump
Microplate Shaking • •
Autoclavable Fluid Path • •
Onboard Software Included • •
LHC Software Compatible • •
Key Features and Application Areas
ELISA • •
Cell-Based Assays • •
Bulk Reagent Dispensing • •
Single-Well Dispense
Dispensing Speed
62
Liquid Handling
MultiFlo FX MicroFill
6 to 1536 standard, low profile and deep well 24, 96 and 384 standard, low profile and deep well
Wash module
AMX Automated Media Exchange module
RAD Random Access Dispense module
Peristaltic dispense pump module
Dual syringe pump module
1–5 1
Peristaltic pump
Single syringe pump
Dual syringe pump
•
• •
•
•
500 nL to 30,000 µL/well 5–6,000 µL/well
•
• •
• •
•
• •
• •
• •
RAD module
AMX module
± 2%; ± 1 µL n/a; ± 1 µL
63
Liquid Handling
Expanded versatility
LHC software is a powerful yet flexible interface for use with Agilent BioTek microplate dispensers
and washers. Any programming sequence possible onboard the liquid handler may be duplicated
from the computer with LHC software. LHC also allows a virtually unlimited number of methods
to be linked together for the most complex liquid handling routines. From a washer’s first prime
routine, to multiple microplate processes over time, and ultrasonic cleaning to dissolve protein or
salt crystal build-up to a final system rinse, LHC software enables unattended operation.
To meet the demands of the GxP laboratory, LHC Secure software offers features to ensure
compliance to 21 CFR Part 11. Flexible multi-user permission levels, and electronic protocol, and
system audit trail signing are all available whenever additional security is required.
Protocol parameters may be quickly printed for safe record keeping. Alternatively, onboard
instrument protocols may be uploaded and backed up on a laboratory’s network. Satellite
research labs working on joint projects can be certain their wash parameters are identical for
experimental integrity.
For automated systems that require SiLA compliant integration, LHC SiLA is available.
64
Liquid Handling
65
Robotics
BenchCel fully automates workflows between several Agilent BioTek liquid handling, detection,
and imaging instruments, including:
The BenchCel microplate handler with an EL406 washer dispenser and Synergy Neo2 hybrid
multimode reader can batch process several ELISA plates. Automated plate washing, reagent
addition, and absorbance measurements facilitate the process to get results quickly.
Agilent VWorks automation control software offers an intuitive graphical interface and dynamic
scheduling capabilities. Users can create and run protocols, forms, and monitor progress of their
workflows from VWorks.
BenchCel’s convenient front-loading stacks can be used in a wide variety of environments: bench
top, hood, or biosafety cabinet. They accommodate a variety of microplate types including deep
well plates.
66
Robotics
Technical details
Dimensions—Agilent BenchCel 2R/4R Microplate Handler General
Overall Height 250 mm stacks 27.8 in 70.1 cm Microplate Types ANSI/SLAS standard microplates,
deep well plates
660 mm stacks 43.8 in 111.1 cm
Capacity: Number of Stacks BenchCel is available in two- or four-stack versions
860 mm stacks 51.8 in 131.6 cm for a range of throughput requirements
Dimensions—Agilent BenchCel 2R Microplate Handler
Liquid Handler Reader/Imager Width Width Depth Depth Stack Height/Capacity 860 mm (34”)/61
(in) (cm) (in) (cm) (14 mm Plates) 660 mm (26”)/47
250 mm (10”)/17
EL406 Epoch 2 56.52 143.56 18.80 47.75
Stack Type Front loading: when opened, rack accepts stack of
EL406 Neo2 64.09 162.79 20.32 51.61 plates for efficiency and convenience
EL406 Cytation 5 62.82 159.56 20.77 52.76
EL406 35.48 90.12 17.27 43.87 Instrument Compatibility Synergy Neo2 hybrid multimode reader
Cytation 5 cell imaging multimode reader
MultiFlo FX with Wash Epoch 2 58.13 147.65 20.83 52.91 Epoch 2 microplate spectrophotometer
MultiFlo FX with Wash Neo2 65.61 166.65 22.35 56.77 406 FX washer dispenser
EL406 washer dispenser
MultiFlo FX with Wash Cytation 5 64.34 163.42 22.80 57.91 MultiFlo FX multimode dispenser
MultiFlo FX with Wash 37.02 94.03 18.94 48.11 Software Agilent VWorks automation control software,
MultiFlo FX without Wash Epoch 2 58.08 147.52 14.80 37.59 integrated with Agilent BioTek Gen5, LHC, and LHC2
Secure software
MultiFlo FX without Wash Neo2 65.61 166.65 16.16 41.05
Safety Features Safety shield, emergency-stop pendant
MultiFlo FX without Wash Cytation 5 64.34 163.42 16.57 42.09
Sensors Plate-presence sensor, rack-presence sensor, plate
MultiFlo FX without Wash NA 37.02 94.03 12.85 32.64 orientation sensor
Epoch 2 38.08 96.72 12.68 32.21
Neo2 45.63 115.90 15.35 38.99
Cytation 5 44.35 112.65 16.34 41.50
Dimensions—Agilent BenchCel 4R Microplate Handler
68
Robotics
Technical details
BioStack 4 BioStack 3 • BioStack Neo • BioStack
General
Microplate Types ANSI/SLAS standard and low-profile 96-, 384-, and 1536-well plates ANSI/SLAS standard and low-profile 96-, 384-, and 1536-well plates
24- and 48-well plates (model dependent) Maximum plate height: 14.6 mm
Maximum plate height: 23.2 mm
Lidded Plate Handling Delidding capability: (lids always removed during processing) 96-, 384-, n/a
and 1536-well plates
Maximum height, including lids: 16.9 mm
Processing Speed < 20 seconds (with delidding) < 10 seconds: Agilent BioTek BioStack 3/Neo microplate stacker
(Plate Exchange Time) < 12 seconds (without lids) < 33 seconds: Agilent BioTek BioStack microplate stacker
Direct Control Washers and dispensers with keypad Washers and dispensers with keypad
interface can directly control Agilent BioTek BioStack microplate stacker interface can directly control Agilent BioTek BioStack microplate stacker
Software (PC Control) Agilent BioTek LHC software for liquid handling instruments (optional) Agilent BioTek LHC software for liquid handling instruments (optional)
Agilent BioTek Gen5 software for imagers Agilent BioTek Gen5 for imagers
Agilent BioTek Gen6 for readers
Physical Characteristics
69
Peripherals
70
Peripherals
Dual-reagent injector
Dual-reagent injector module enables applications that require rapid inject/read functions, like
calcium flux assays. Two precision syringes supply rapid injection of 5 to 1,000 µL in 1 µL
increments, directly into the microplate wells inside the reading or imaging chamber. Injectors are
available for Lionheart FX, Cytation, Synergy Neo2, Synergy H1, and Synergy HTX. The flexible
dual-reagent injector module automates precise reagent additions while saving time in your
laboratory.
CO2/O2 controller
The CO2 and O2 gas controller has control over CO2 and O2 concentrations within the instrument
environment to facilitate live cell assays. The controller regulates the environment for pH buffering
or to create a hypoxic condition. Automation of live cell-based assays in microplates allows for
high-throughput analysis and requires cell-friendly microplate instrumentation. Automated live cell
assays enable walk-away processes and increased laboratory efficiency.
71
Peripherals
72
Peripherals
Replacement cassettes
Agilent BioTek offers replacement cassettes for Agilent BioTek dispensers and washers
equipped with one or more peristaltic pumps. A range of tubing diameters and tip types
allows you to choose the cassette that is most appropriate for your application. Cassettes
can be easily and quickly ordered online from Microplate Dispenser Cassettes, BioTek
Dispensers | Agilent.
73
Learn more and buy online:
www.agilent.com/lifesciences/biotek
Europe
info_agilent@agilent.com
Asia Pacific
inquiry_lsca@agilent.com