Taking the Certification Test
Each question has only one correct answer. Please record all answers on this answer
sheet. The order of the questions in the test roughly follows the order of topics covered
in class. All questions are equally weighted. A passing score is 90%.

Returning the Certification Test


Option 1: Fax the answer sheet (following page) to Yaskawa Technical Training
Services at (847) 887-7185.
Option 2: E-mail the answers to all questions to training@yaskawa.com. Be sure to
Include all of the contact information listed on the answer sheet.
Option 3: Mail the answer sheet to Yaskawa Technical Training Services at the
address shown on the bottom of this page.

Receiving Your Score


When the test is taken during the training class, you will receive your score in class as
soon as it can be graded. When taken as a CLEP test, receive your score from Technical
Training Services by sending an email to training@yaskawa.com or by calling Karen
Kolacki at 847-887-7228. In either case, you may review your answers only if a passing
score is received.

Yaskawa America, Inc. CT.AFD.01.eLM


2121 Norman Drive South 8/18/2011
Waukegan IL 60085 Rev 1.3
Page 1 of 5
Certification Test
eLM.AFD.01 (DeviceNet)

Answer Sheet:
1. 6. 11. 16. 21.
2. 7. 12. 17. 22.
3. 8. 13. 18. 23.
4. 9. 14. 19.
5. 10. 15. 20.

24.

25.

Contact Information:
Name: Title:
Company: Email:
Address:
Phone Number: Fax number:
Supervisor’s Name/ Title:
Test Date:

Yaskawa America, Inc. CT.AFD.01.eLM


2121 Norman Drive South 8/18/2011
Waukegan IL 60085 Rev 1.3
Page 2 of 5
Certification Test
eLM.AFD.01 (DeviceNet)
QUESTIONS

1. ODVA stand for what?


a. On-Line Device Voltage c. Organization of
Assembly Developers and Value
b. Open DeviceNet Vendors Adders
Association d. Nothing

2. Yaskawa sells complete DeviceNet Networks.


a. True b. False

3. The DeviceNet master always controls the Drive’s Run command.


a. True b. False

4. It is important to use ODVA certified cables on a DeviceNet network.


a. True b. False

5. An Object defines what?


a. Class, Instance, and Assembly.
b. MAC ID and network baud rate.
c. Class, Instance, and Attribute.
d. Where assemblies are mapped in the scanner.

6. What voltage is used on a DeviceNet bus?


a. 5 VDC c. 24 VDC
b. 12 VDC d. 120 VAC

7. Which one of the following is not true about Explicit Messaging?


a. Unlike polled messages, they are non-repeating.
b. They are extremely easy to use.
c. All Yaskawa DeviceNet options except gateways support them.
d. They can be used to change a Drive parameter setting via the network.

8. All DeviceNet networks should use single point grounding techniques.


a. True b. False

9. The same assemblies are available in all Yaskawa DeviceNet solutions.


a. True b. False

10. The CAN_L and CAN_H pair of an ODVA certified DeviceNet cable are which
color?
a. Black and Red b. Blue and White

11. What is the ODVA website address?


a. www.odva.com c. www.odva.org
b. www1.odva.us.gov d. www.odva.net

Yaskawa America, Inc. CT.AFD.01.eLM


2121 Norman Drive South 8/18/2011
Waukegan IL 60085 Rev 1.3
Page 3 of 5
Certification Test
eLM.AFD.01 (DeviceNet)

12. A DeviceNet master must be a PLC.


a. True b. False

13. Which Yaskawa DeviceNet solution allows for assemblies to be set via
parameter?
a. CM059 c. V7N
b. CM054 d. CM053

14. A DeviceNet configuration tool can be used to do which of the following?


a. It can be the network ground point.
b. Be the scanner on the network.
c. Map assembly information in the scanner.
d. Set the network baud rate.

15. Which is not a reason to use a CM059?


a. Can be used for multiple different Drive models.
b. Assembly for controlling the Drives digital outputs.
c. Allows using the 3CN port for another option board.
d. Is able to be configured for a Master that uses Idle Mode.

16. To replace an EDS file, just overwrite it.


a. True b. False

17. All output assemblies are 4 bytes.


a. True b. False

18. The Gateway used as part of the GPD506/P5 DeviceNet solution translates
between which two protocols?
a. DeviceNet and Modbus c. DeviceNet and Modbus
RTU Plus
b. DeviceNet and Ethernet d. RS-232 and RS-485

19. When using the DeviceNet master to set the Drive’s speed command it may be
necessary to set the following parameter in the Drive:
a. Reference Source (b1-01 or n004).
b. Frequency Reference Display Units (o1-03 or n035).
c. Frequency Reference Resolution/Unit (n152).
d. All of the above.

Yaskawa America, Inc. CT.AFD.01.eLM


2121 Norman Drive South 8/18/2011
Waukegan IL 60085 Rev 1.3
Page 4 of 5
Certification Test
eLM.AFD.01 (DeviceNet)

20. What makes the V7N unique?


a. One of the few Drives in the market with built-in DeviceNet.
b. The most assemblies of any Yaskawa DeviceNet solution.
c. The only Yaskawa DeviceNet solution with the DeviceNet LEDs.
d. The only Drive to be able to work with a master in Idle Mode.

21. Which of the following is NOT true regarding grounding procedures?


a. Ground the option card to the Drive.
b. Use single-point grounding procedures.
c. Use multiple ground loops to insure an adequate earth ground.
d. The network power supply and the Drive should be grounded to the same
point.

22. The network drain/shield wire should never be attached to a Yaskawa DeviceNet
board.
a. True b. False

23. EDS files must be registered one at a time.


a. True b. False

24. What two options are there for using a V7 Drive on a DeviceNet network?

25. What would the new name for the EDS file for a 480Vac 18 kW F7 that is using a
CM056 board with version 2.11 firmware?