K50-CP
MARINE GENERATING SETS
PRODUCT S P E C I F I C AT I O N S
PRIME POWER R AT I N G S
Frequency 50 hz 50 hz 60 hz 60 hz
RPM 1500 1500 1800 1800
Voltages Available 380 400, 415, 440 416 440, 460, 480
g/kWh (lb/hp-hr) 191 (.315) 190 (.312) 193 (.318) 191 (.315)
L/hr (U.S. g/hr) 233 (61.6) 244 (64.6) 280 (74.1) 291 (77.0)
C POWER DESIGN F E AT U R E S
World class Cummins Marine diesel engines matched to industry Available with multi-station alarm and monitoring panels via a
leading Newage Stamford alternators. Designed, integrated and local digital network to match application requirements.
assembled for optimal efficiency and performance.
Integrated alarm system can be configured to communicate with
Engineered for the tough demands of the marine environment ship's central data systems.
with superior durability and high uptime requirements.
Flexible configurations available to customize the generating set
Simplified vessel integration with less-complex mechanical to the vessel's operation and requirements.
connections.
MARINE GENERATING SETS
K50-CP
G E N E R AT O R SET DIMENSIONS
Length Width Height Weight (Dry)
mm in mm in mm in kg lb
IMO emissions certified by Lloyds Register and Classification Comprehensive warranty applies to entire generating set and
Society approvals available. is valid globally.
Classed units fitted with superior aluminum conduited wiring Major generator set components are optimized to work most
harness, duplex filtration and type-approved hardware. efficiently in the complete Cummins designed system.
N E WA G E A LT E R N A T O R
PRIME POWER R AT I N G
F E AT U R E S
DEFINITION
6 wire, 3-phase alternator provides a broad range of
re-connectable outputs. Engines with this rating are available for an unlimited number
of hours per year in variable load applications. Variable load is
Designed specifically for marine applications with an IP23 not to exceed a 70 percent average of the rated power during
terminal box. any operating period of 250 hours. Total operating time at 100
percent Prime Power shall not exceed 500 hours per year.
Two bearing Alternator close coupled by a class approved
flexible coupling using a permanent magnet generator A 10 percent overload capability is available for a period of one
provides constant excitation under all conditions. hour within a twelve hour period of operation. Total operating time
at the 10 percent overload power shall not exceed 25 hours per
Standard 2/3 pitch windings avoid excessive neutral currents. year. This power rating conforms to ISO 8528 guidelines.