Sensors-Switches 231227 130826
Sensors-Switches 231227 130826
Sensors-Switches 231227 130826
Features
• Very compact width 9.8mm.
• Copy function.
• Easy operation: 3-step setting.
• Output options: 2 PNP/NPN or 1 PNP/NPN with analogue output 1-5V.
• Additional functions: password setting, power saving.
How to Order
Rated pressure range
ISE10 –0.100 to 1.000 MPa
M5R G
Piping port
R1/8/Side ported
Sensors &
Switches
Note) Fixed unit:
For vacuum/compound pressure: kPa
For positive pressure: MPa
Output specifications
Product Recommendation
A NPN open collector 2 outputs
B PNP open collector 2 outputs
C Note) NPN open collector 1 output + Analogue voltage Stocked items for fast delivery
E Note) PNP open collector 1 output + Analogue voltage
Note) Made to Order ISE10-M5-B-G ZSE10-M5-B-G ZSE10F-M5-B-G
Related Products
For more product options and details see our specific catalogues or on-line information.
1206 Series ZSE10(F)/ISE10 – Compact Digital Pressure Switch
Specifications
Model ZSE10 (vacuum pressure) ZSE10F (compound pressure) ISE10 (positive pressure)
Rated pressure range 0.0 to –101.0 kPa –100.0 to 100.0 kPa –0.100 to 1.000 MPa
Set pressure range/Pressure display range 10.0 to –105.0 kPa –105.0 to 105.0 kPa –0.105 to 1.050 MPa
Withstand pressure 500 kPa 500 kPa 1.5 MPa
Minimum unit setting 0.1 kPa 0.1 kPa 0.001 MPa
Fluid Air, Non-corrosive gas, Non-flammable gas
Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With power supply polarity protection)
Current consumption 40 mA or less
Switch output NPN or PNP open collector 2 outputs (Selectable)
Maximum load current 80 mA
Maximum applied voltage 28 V (With NPN output)
Residual voltage 2 V or less (With load current of 80 mA)
Response time 2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)
Short circuit protection Yes
Repeat accuracy ±0.2% F.S. ±1 digit
Hysteresis mode
Hysteresis Variable (0 or above) Note)
Window comparator mode
Output voltage (Rated pressure range) 1 to 5 V ±2.5% F.S. 0.6 to 5 V ±2.5% F.S.
Analog Voltage
Linearity ±1% F.S.
output output
Output impedance Approx. 1 kΩ
Display 3 1/2 digit, 7-segment indicator, 1-colour display (Red)
Display accuracy ±2% F.S. ±1 digit (at 25°C ±3°C ambient temperature)
Indicator light Lights up when output is turned ON. OUT1: Green OUT2: Red
Enclosure IP40
Operating temperature range Operating: –5 to 50°C, Stored: –10 to 60°C (No freezing or condensation)
Environmental Operating humidity range Operating and stored: 35 to 85% RH (No condensation)
resistance Withstand voltage 1000 VAC for 1 min. between live parts and enclosure
Insulation resistance 50 MΩ or more between live parts and enclosure (at 500 VDC measured via megohmmeter)
Temperature characteristics ±2% F.S. (at 25°C in an operating range of –5 to 50°C)
Oil-resistant vinyl cabtire cable
Lead wire
5 cores, Cross section: 0.15 mm2 (AWG26) Insulator O.D.: 1.0 mm
Standard CE Marking, UL (CSA), RoHS compliant
Note) If the applied voltage fluctuates around the set-value, the hysteresis must be set to a value more than the fluctuating width, otherwise chattering will occur.
Piping Specifications
Model M5 M5R 01
M5 x 0.8 M5 x 0.8 R1/8
Port size
(Side ported) (Rear ported) (Side ported)
Wetted Sensor pressure receiving area Sensor pressure receiving area: Silicon
part
Sensors &
Piping port
material O-ring: HNBR
With lead wire with connector (5 cores, 2 m) 55 g 63 g
Mass
Without lead wire with connector 15 g 23 g
Options
When optional parts are required separately, use the following part numbers to place an order.
Part no. Option
ZS-39-5G Lead wire with connector (with connector cover) (5 cores, 2 m)
ZS-39-B Panel mount adapter
ZS-39-D Panel mount adapter + Front protective cover
ZS-39-R DIN rail adapter
ZS-39-01 Front protective cover
ZS-39-N1 Note) R1/8 piping adapter
Note) Made to Order
Compact Digital Pressure Switch – Series ZSE10(F)/ISE10 1207
Dimensions
ZSE10(F)/ISE10-M5--
(30)
2 x 3.3
(12) M5 x 0.8
1.2
13
25
3.5
51.8 4.2 9.8
6.4
(7.7)
ZSE10(F)/ISE10-M5R--
4.5 M5 x 0.8
1.2
25
51.8 4.2
9.8
6.4
ZSE10(F)/ISE10-01--
Sensors &
2 x 3.3 Switches
1.2
11
13
25
8 3.5
R1/8
12.5 51.8 4.2 9.8
6.4
For more product options and details see our specific catalogues or on-line information.
1208 Series ZSE10(F)/ISE10 – Compact Digital Pressure Switch
Dimensions
ZSE10(F)/ISE10-M5R--
Panel mount adapter + Front protective cover
M5 x 0.8
21.4
10.2
(67)
6.5
3
64.6
17.8
17.5
ZSE10(F)/ISE10-M5--
9.8 M5 x 0.8
With DIN rail
1.2
25
3.5
53.5
6.4
57.2 –0.4
0
ss
0
le
s
2
l
x
3
R
x
4
14.8 x n pcs. + 3 x (n pcs. – 1)
Compact Digital Pressure Switch – Series ZSE10(F)/ISE10 1209
Wiring
A B
NPN (2 outputs) PNP (2 outputs)
Brown DC (+) Brown DC (+)
Load
Black OUT1 Black OUT1
Main circuit
Main circuit
Load
+ Load +
12 to 12 to
White OUT2 White OUT2
– 24 VDC – 24 VDC
FUNC Note) Load
FUNC Note)
Blue DC (–) Blue DC (–)
Max. 28 V, 80 mA Max. 80 mA
Residual voltage 2 V or less Residual voltage 2 V or less
C E
NPN (1 output) + Analogue voltage output PNP (1 output) + Analogue voltage output
Main circuit
Sensors &
Switches
For more product options and details see our specific catalogues or on-line information.
1210 Series ZSE30A/ISE30A – Digital Pressure Switch
2-colour Display ®
Features
Features
• Adjustable vacuum, positive and compound pressure switch with display.
• Large, easy to read, 2 colour (green/red), 4 digit display.
• Easy operation: 3-step setting and copy display.
• Analogue output: 4-20mA or 1-5V.
• Switch output: 2 PNP/NPN or 1 pnp/npn.
• Replaceable one touch fittings.
• Additional functions: Secret code setting function,
power-saving function, resolution-switch function.
How to Order
Output Accessories for mounting
N NPN open collector 1 output — None
P PNP open collector 1 output Bracket A
A NPN open collector 2 outputs
B PNP open collector 2 outputs
C Note) NPN open collector 1 output + Analogue voltage output ZS-38-A1
R1/8
01 (M5 female
Lead wire with connector
threaded) (Lead wire length 2 m) Note)
Display unit
Straight type With unit display L
One-touch fitting —
C4H switching function
ø4 mm, ø5/32 inch
M Fixed SI unit Note 2)
With unit display
C6H One-touch fitting Note 1)
P switching function Lead wire with connector
Sensors &
ø6 mm
Switches
Specifications
Model ZSE30A (Vacuum pressure) ZSE30AF (Compound pressure) ISE30A (Positive pressure)
Rated pressure range 0.0 to –101.0 kPa –100.0 to 100.0 kPa –0.100 to 1.000 MPa
Regulating pressure range 10.0 to –105.0 kPa –105.0 to 105.0 kPa –0.105 to 1.050 MPa
Proof pressure 500 kPa 500 kPa 1.5 MPa
Setting/display resolution 0.1 kPa 0.1 kPa 0.001 MPa
Applicable fluid Air, non-corrosive gas, non-flammable gas
Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (with power supply polarity protection)
Current consumption 40 mA or less
Switch output NPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)
Maximum load current 80 mA
Maximum applied voltage 28 V (with NPN output)
Residual voltage 1 V (with load current of 80 mA)
Response time 2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)
Short circuit protection With short circuit protection
Repeatability ±0.2% F.S. 1 digit
Hystere- Hysteresis mode
Variable (0 or above) Note 1)
sis Window comparator mode
Note 2) Output voltage 1 to 5V ±2.5% F.S. (with rated pressure range) 0.6 to 5 V ±2.5% F.S. (with rated pressure range)
Voltage
Linearity ±1% F.S.
output
Output impedance Approx. 1 k
Analogue
output Note 3) Output current 4 to 20 mA ±2.5% F.S. or less (with rated pressure range) 2.4 to 20 mA ±2.5% F.S. or less (with rated pressure range)
Current Linearity ±1% F.S.
output Maximum load impedance: 300 Ω with power supply voltage of 12 V; 600 Ω with power supply voltage of 24 V
Load impedance
Minimum load impedance: 50 Ω
Display 4-digit, 7-segment, 2-colour LCD (Red and Green)
Display accuracy ±2% F.S. ±1 digit (ambient temperature of 25 ±3ºC)
Indicator light Lights up when switch output is ON. OUT1: Green, OUT2: Red
Enclosure IP40
Operating temperature range Operating: 0 to 50ºC, Stored: –10 to 60ºC (no freezing or condensation)
Environ- Operating humidity range Operating/Stored: 35 to 85% RH (no condensation)
ment Withstand voltage 1000 VAC for 1 minute between live parts and enclosure
resistance Insulation resistance 50 MΩ or more between live parts and enclosure (at 500 VDC Mega)
Temperature characteristics ±2% F.S. (based on 25ºC)
Oilproof heavy-duty vinyl cable, 3 cores ø3.5, 2 m
Lead wire
4 cores Conductor area: 0.15 mm2 (AWG26), Insulator O.D.: 1.0 mm
Standards CE Marking, UL/CSA, RoHS compliance
Note 1) If applied pressure fluctuates near the set value, set the hysteresis above the fluctuation range to prevent chattering.
Note 2) When analogue the voltage output is selected, a simultaneous selection of switch output and current output is not available.
Note 3) When analogue the current output is selected, a simultaneous selection of switch output and voltage output is not available.
Piping Specifications
Sensors &
Model 01 C4H C6H C4L C6L
Port size R1/8
M5 x 0.8
— — — — Switches
ø4 mm
One-touch fitting, Straight type — ø6 mm — —
ø5/32 inch
ø4 mm
One-touch fitting, Elbow type — — — ø6 mm
ø5/32 inch
Wetted Sensor pressure receiving area Sensor pressure receiving area: Silicon
parts C3602 (electroless nickel plated) PBT, POM, Stainless steel 304, C3604 (electroless nickel plated)
material Piping port O-ring: HNBR O-ring: NBR
Including lead wire with connector (3 cores, 2 m) 81 g 70 g 71 g 75 g 73 g
Weight Including lead wire with connector (4 cores, 2 m) 85 g 74 g 75 g 79 g 77 g
Excluding lead wire with connector 43 g 32 g 33 g 37 g 35 g
For more product options and details see our specific catalogues or on-line information.
1212 Series ZSE30A/ISE30A – Digital Pressure Switch
Options
When optional parts are required separately, use the following part numbers to place an order.
Dimensions
25 8 9.5 30
200.1 2 x M3 x 0.5
Lead wire with connector
thread depth 4
M5 x 0.8
10
200.1
30
01: R1/8
N01: NPT1/8
Wi 1.5
ac dth
fla ross
ts
12
Sensors &
Switches
Straight Elbow
17.55 20.7
10.85
ø9.3
With one-touch fitting 10.85
Digital Pressure Switch – Series ZSE30A/ISE30A 1213
With bracket
42.5 30
25 20
(41.4)
42.5
20
45
30
5.2
14.7
20
9.6
5.2
45
30
5.2
5.5
5.2
9.1
13.6
7.5 7.2
Note) Bracket configuration allows 16.4
mounting in four directions. 20
Bracket A Bracket B
Dimensions
Panel mount 7.2 17.8 8 9.5
47.8
34.5
R4
.5
R4.5
34.5
21
8.5
Sensors &
Switches
Panel thickness 0.5 to 6
For more product options and details see our specific catalogues or on-line information.
1214 Series ZSE30A/ISE30A – Digital Pressure Switch
Dimensions
0
31 –0.4 31 x n pcs. + 3.5 x (n pcs. – 1)
31 –0.4
31 –0.4
0
4
x
R2
4x
24 or more
or
R2
le
ss
or
les
s
0
31 –0.4 24 or more
Sensors &
Switches
4
x
R2
or
le
ss
Digital Pressure Switch – Series ZSE30A/ISE30A 1215
Wiring
Z/ISE30A(F)
Output
N P
NPN (1 output) PNP (1 output)
Load
Main circuit
Main circuit
+ +
12 to 12 to
Black OUT
– 24 VDC Black OUT – 24 VDC
Max. 28 V, 80 mA Max. 80 mA
Residual voltage 1 V or less Residual voltage 1 V or less
A B
NPN (2 outputs) PNP (2 outputs)
Brown DC (+) Brown DC (+)
Load
Black OUT1 Black OUT1
Main circuit
Main circuit
Load
+ Load +
12 to 12 to
White OUT2 White OUT2
– 24 VDC – 24 VDC
FUNC Load
FUNC
Blue DC (–) Blue DC (–)
∗ The FUNC terminal is connected using a dedicated lead wire (ZS-38-5L or ZS-38-U) when the copy function is used.
For more product options and details see our specific catalogues or on-line information.
1216 Series ZSE30A/ISE30A – Digital Pressure Switch
Wiring
C E
NPN (1 output) + Analog voltage output PNP (1 output) + Analog voltage output
Load
Black OUT1
Black OUT1
Main circuit
Main circuit
+ +
White OUT2 12 to White OUT2 12 to
24 VDC 24 VDC
– –
Load
Load
FUNC
Load
FUNC
Max. 28 V, 80 mA Max. 80 mA
Residual voltage 1 V or less Residual voltage 1 V or less
D F
NPN (1 output) + Analog current output PNP (1 output) + Analog current output
Load
Black OUT1
Black OUT1
Main circuit
Main circuit
+ +
White OUT2 12 to White OUT2 12 to
24 VDC 24 VDC
– –
Load
Load
FUNC
Load
FUNC
Max. 28 V, 80 mA Max. 80 mA
Residual voltage 1 V or less Residual voltage 1 V or less
∗ The FUNC terminal is connected using a dedicated lead wire (ZS-38-5L or ZS-38-U) when the copy function is used.
High Precision Digital Pressure Switch – Series ZSE40A(F)/ISE40A 1217
2-colour Display ®
Features
• Easy to read, 2 colour (green/red) display.
• IP65 construction.
• Easy operation: 3-step setting.
• Output options: 2 PNP/NPN with analogue output
4-20mA or 1-5V or with copy function.
• Additional functions: password setting, power saving.
G1/8
Output specifications
WF1 Note)
G1/8 R NPN open collector 2 outputs + Analogue voltage/Auto-shift switching
G1/8 T PNP open collector 2 outputs + Analogue voltage/Auto-shift switching
S NPN open collector 2 outputs + Analogue current/Auto-shift switching
V PNP open collector 2 outputs + Analogue current/Auto-shift switching
X NPN open collector 2 outputs + Copy function
Note) M5 x 0.8
M5 Y PNP open collector 2 outputs + Copy function
(Female thread)
M5 x 0.8
C6 ø6 one-touch fitting
Sensors &
ø4, ø6 one-touch fitting
Switches
Stocked items for fast delivery
Note) Made to Order
Combination of piping specifications with option 1 and part numbers of options ISE40A-01-T ZSE40A-01-T ZSE40AF-01-T
Option 1 Piping ISE40A-01-V ZSE40A-01-V ZSE40AF-01-V
Description Symbol Part no. 01 N01 W1 WF1 M5 C4 C6 ISE40A-01-Y ZSE40A-01-Y ZSE40AF-01-Y
Bracket A A ZS-24-A – – – ISE40A-C4-T ZSE40A-C4-T ZSE40AF-C4-T
Bracket B B ZS-24-B – – – – – ISE40A-C4-V ZSE40A-C4-V ZSE40AF-C4-V
Bracket D D ZS-24-D – – – ISE40A-C4-Y ZSE40A-C4-Y ZSE40AF-C4-Y
Panel mount adapter E
ZS-35-C – – – – –
ZS-35-D – – ISE40A-C6-T ZSE40A-C6-T ZSE40AF-C6-T
Panel mount adapter +
F
ZS-35-F – – – – – ISE40A-C6-V ZSE40A-C6-V ZSE40AF-C6-V
Front protective cover ZS-35-G – – ISE40A-C6-Y ZSE40A-C6-Y ZSE40AF-C6-Y
Related Products
For more product options and details see our specific catalogues or on-line information.
1218 Series ZSE40A(F)/ISE40A – High Precision Digital Pressure Switch
Specifications
Model ZSE40A (vacuum pressure) ZSE40AF (compound pressure) ISE40A (positive pressure)
Rated pressure range 0.0 to –101.3 kPa –100.0 to 100.0 kPa –0.100 to 1.000 MPa
Display/Set pressure range 10.0 to –105.0 kPa –105.0 to 105.0 kPa –0.105 to 1.050 MPa
Withstand pressure 500 kPa 500 kPa 1.5 MPa
Display/Minimum unit setting 0.1 kPa 0.1 kPa 0.001 MPa
Applicable fluid Air, Non-corrosive gas, Non-flammable gas
Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (with power supply polarity protection)
Current consumption 45 mA or less
Switch output NPN or PNP open collector 2 outputs (Selectable)
Maximum load current 80 mA
Maximum applied voltage 28 V (at NPN output)
Residual voltage 1 V or less
Response time 2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)
Short circuit protection Yes
Repeat accuracy ±0.2% F.S. ±1 digit
Hysteresis mode
Hysteresis Variable (0 or above) Note 1)
Window comparator mode
Output voltage
Note 2) 1 to 5 V ±2.5% F.S. 0.6 to 5 V ±2.5% F.S.
Voltage (Rated pressure range)
output Linearity ±1% F.S.
Output impedance Approx. 1 kΩ
Analogue Output current
output 4 to 20 mA ±2.5% F.S. 2.4 to 20 mA ±2.5% F.S.
(Rated pressure range)
Note 3)
Current Linearity ±1% F.S.
output Maximum load impedance : 300 (Power supply voltage 12 V)
Load impedance 600 (Power supply voltage 24 V)
Minimum load impedance : 50Ω
Auto-shift input Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input
Display 3 1/2-digit, 7-segment, 2-colour LCD (Red/Green)
Display accuracy ±2% F.S. 1 digit (Ambient temperature of 25 ±3°C)
Indicator light Lights up when output is turned ON. OUT1, OUT2: Orange
Enclosure IP65
Operating temperature range Operating: –5 to 50°C, Stored: –10 to 60°C (No freezing or condensation)
Operating humidity range Operating/Stored: 35 to 85% RH (No condensation)
Environment Withstand voltage 1000 VAC for 1 minute between live parts and case
resistance Insulation resistance 50 MΩ or more between live parts and case (at 500 VDC measured via megohmmeter)
Temperature characteristics ±2% F.S. (Based on 25°C)
Oilproof heavy-duty vinyl cable
Lead wire
ø3.5, 2 m Conductor area: 0.15 mm2 (AWG26) Insulator O.D.: 0.95 mm
Standards CE marking, UL (CSA), RoHS compliance
Note 1) If the applied voltage fluctuates around the set-value, the hysteresis must be set to a value more than the fluctuating width, otherwise chattering will occur.
Note 2) When the analogue voltage output is selected, the analogue current output cannot be selected.
Sensors &
Switches
Note 3) When the analogue current output is selected, the analogue voltage output cannot be selected.
Piping Specifications
Options
When optional parts are required separately,
Options/Part No. use the following part numbers to place an order.
Part no. Option
ZS-24-A Bracket A, With 2 mounting screws each of M3 x 5L and M4 x 5L
ZS-24-B Bracket B, With 2 mounting screws M4 x 5L
ZS-24-D Bracket D, With 2 mounting screws each of M3 x 5L and M4 x 5L
ZS-35-C Panel mount adapter (Piping: For 01)
Panel mount adapter
ZS-35-D (Piping: For WF1/M5/C4/C6)
Panel mount adapter + Front protective cover
ZS-35-F (Piping: For 01)
Panel mount adapter + Front protective cover
ZS-35-G (Piping: For WF1/M5/C4/C6)
ZSE40A(F)/ISE40A-01
14.7
2 40.2
M5 x 0.8 thread depth 5
20 26.2 4.5
30
20
30
10
2
s1
ø3.5
Wi
ZSE40A(F)/ISE40A-WF1
8.8
Atmospheric vent port ø2.6
Sensors &
Switches
14.7
6
WF1: G1/8
12
2 38.2
2 x M4 x 0.7 WF1: G1/8
20 26.2 4 30
thread depth 4
7
20
30
19
10
.5
R6
ø3.5
For more product options and details see our specific catalogues or on-line information.
1220 Series ZSE40A(F)/ISE40A – High Precision Digital Pressure Switch
Dimensions
ZSE40A(F)/ISE40A-C4
-C6
28.2
41.2
14.7
7
One-touch fitting ø4, ø6
32.3
12.8 30
8 20
2x
4.5
28.15
22.15
44.3
30
19
25.4
10
-M5
8.5
19
M5 x 0.8 thread depth 5
ZSE40A(F)/ISE40A-01--A
Sensors &
Switches
With bracket
43.2
4.5
11.5
15
4.5
6.5
20
30
20
20
55
40
1.6
High Precision Digital Pressure Switch – Series ZSE40A(F)/ISE40A 1221
Dimensions
ZSE40A(F)/ISE40A-WF1--B
With bracket
44.3
12.1
30
45
30
4.5
4.5
4.5
1.6
6.5
20
ZSE40A(F)/ISE40A-01--D
With bracket
47.2
11.5
15
4.2
4.5
7.5 7.2
22
30
Sensors &
Switches
55
40
1.6
35
For more product options and details see our specific catalogues or on-line information.
1222 Series ZSE40A(F)/ISE40A – High Precision Digital Pressure Switch
Dimensions
ZSE40A(F)/ISE40A-01--E
Panel mounting
38.6
43.2
4 25.2
40
43.6
40
Panel thickness 1 to 5
ZSE40A(F)/ISE40A-01--F
38.6
46.7
7.5 25.2
Sensors &
40
Switches
51.2
Panel thickness 1 to 5
High Precision Digital Pressure Switch – Series ZSE40A(F)/ISE40A 1223
Dimensions
Panel fitting dimensions
36 0.3
36 0.3
4 4
x xR
R3
or 3
or
67 or more
le les
ss s
Panel thickness 1 to 5 mm
Note) This is the minimum value for the piping method 01 or N01.
Take the piping material and tubing into account for design. When the corner is to have radius, it must be R3 or less.
Wiring
-R -S -R/-S
NPN (2 outputs) + NPN (2 outputs) + NPN (2 outputs) +
Analogue voltage output Analogue current output Auto-shift input
Brown DC (+) Brown DC (+) Brown DC (+)
Main circuit
Main circuit
-T -V -T/-V
PNP (2 outputs) + PNP (2 outputs) + PNP (2 outputs) +
Analogue voltage output Analogue current output Auto-shift input
Brown DC (+) Brown DC (+) Brown DC (+)
Sensors &
Switches
Grey Analogue output Grey Analogue output Grey Auto-shift input
Main circuit
Main circuit
Main circuit
Load Load
+ 12 to + 12 to Black OUT1 + 12 to
Black OUT1 Load – 24 VDC Black OUT1 Load – 24 VDC Load – 24 VDC
White OUT2 White OUT2 White OUT2
c
Load Load Load
-X -Y
NPN (2 outputs) + PNP (2 outputs) +
Copy function Copy function
Brown DC (+) Brown DC (+)
Load
+ 12 to Black OUT1 + 12 to
Black OUT1 Load – 24 VDC Load – 24 VDC
White OUT2
White OUT2 Load
Max. 28 V, 80 mA Max. 80 mA
Residual voltage 1 V or less Residual voltage 1 V or less
For more product options and details see our specific catalogues or on-line information.
1224 Series ZSE80/ISE80 – 2-colour Display, Digital Pressure Switch for Fluids
Features
Features
• Stainless steel construction. Make ZSE80/ISE80 suitable for working
with a wide range of fluids, even aggresive.
• Four pressure ranges available working in the following regimes:
- Vacuum: from -0.1 to 0MPa
- Compound: from -0.1 to +0.1 MPa
- Positive: from -0.1 to +1 MPa and from -0.1 to +2 MPa.
• 2 -colour display (LCD).
• Low leakage versions available.
• Simplied operation.
• Rear and bottom piping available as standard options.
• Output options: PNP/NPN/Analogue output.
Rated pressure range Accessories for mounting
How to Order 80 –0.1 to 1 MPa None
80H –0.1 to 2 MPa With bracket
For positive
pressure ISE 80 02 B
For vacuum/ ZS-24-A ZS-35-A
compound pressure ZSE 80 02 B Rear ported Bottom ported
With bracket Note)
Rated pressure range
80 0 to –101 kPa
80F –100 to 100 kPa
Piping
ZS-24-D
R1/4 Rear ported
02 (M5 female threaded)
Panel mount
G1/4
F02 (M5 female threaded)
C01 Rc1/8
A2 URJ1/4 ZS-35-B
B2 TSJ1/4
R1/4 Bottom ported
02L
(M5 female threaded)
C01L Rc1/8 ZS-35-C
A2L URJ1/4 Rear ported Bottom ported
B2L TSJ1/4 Panel mount + Front protection cover
ZS-35-E
Sensors
Switches
Input/Output
Sensors
Switches
Product Recommendation
ISE80-02-B ISE80-F02-T ZSE80F-A2-B ISE80H-02L-V Series VNB - 2 Port Air Operated Valves - page 1466
ISE80-02L-B ISE80-F02-V ZSE80F-A2L-B ISE80H-02-T Series VXZ - Pilot Operated 2 Port Solenoid Valves - page 1451
Series PF3W - Digital Flow Switch for Water - page 1317
ISE80-02L-T ZSE80-A2L-B ZSE80F-A2L-B ISE80H-02-V
ISE80-02L-V ZSE80-F02-B ZSE80F-F02-B ISE80H-F02-B
ISE80-02-T ZSE80F-02-B ISE80H-02-B ISE80H-F02-V
ISE80-02-V ZSE80F-02-T ISE80H-02L-B
ISE80-F02-B ZSE80F-02-V ISE80H-02L-T
2-colour Display, Digital Pressure Switch for Fluids – Series ZSE80/ISE80 1225
Specifications
& &
Switches
Temperature characteristics ±3% F.S. (Based on 25ºC, within operating temperature range)
Sensors
Switches
Oilproof heavy-duty vinyl cable, 3 cores (N.P) ø3.5, 2 m Sensors
Lead wire 4 cores (A.B) Conductor area: 0.15 mm2 (AWG26)
5 cores (R.T.S.V) Insulator O.D.: 0.95 mm
Standards CE marking, UL/CSA, RoHS compliance
∗ G1/4 is available for rear ported only.
Piping Specifications
For more product options and details see our specific catalogues or on-line information.
1226 Series ZSE80/ISE80 – 2-colour Display, Digital Pressure Switch for Fluids
Dimensions
02
N02 8.8
ZSE/ISE8- F02
C01
Atmospheric vent port ø2.6
A2
B2
14.7
49.6
M5 thread depth 5 2 (N02: 50.1)
20 26.2 8.45 30
20
30
ac dth
fla oss
17
Wi
10
r
ts
2 x M3 thread depth 4
Piping port
02: R1/4
ø3.5
2 46.2 2 45.2
26.2 10.55
26.2 8.45
Piping port
Piping port G1/4
Rc1/8
19
27.7 21.7
8.45 8.45
Dimensions
02L
N02L
ZSE/ISE8- C01L
A2L
B2L
8.8 Atmospheric vent port ø2.6
10.3
29.5
dth
M5 thread depth 5 Wi ss
ro
ac 17
ts
fla
2 41
20 25.2 30
20
30
(N02L: 61.5)
60.5
2 x M3
thread depth 4 10
ø3.5
Piping port
02L: R1/4
2 41
25.2
& &
Switches
49.5
Sensors
58.8
Switches
64.8
Sensors
Piping port
Rc1/8
Piping port Piping port
URJ1/4 TSJ1/4
For more product options and details see our specific catalogues or on-line information.
1228 Series ZSE80/ISE80 – 2-colour Display, Digital Pressure Switch for Fluids
Dimensions
A
With bracket (Rear ported)
30
• ZS-24-A
20
20
43.2
11.5
55
4.5
40
15
.5
ø4
6.5
1.6 20
39.7
View A
43.2
55
4.5
40
11.5
15
4.2
7.2 7.5
1.6
22
39.7 35
2
• ZS-35-A
25.2
47
35.5
Sensors
Switches
Sensors
Switches
16.3
40.3
& &
1.5
50
4 x ø4.5
49 40
20 43 30
30
20
10
60.5
ø3.5
2-colour Display, Digital Pressure Switch for Fluids – Series ZSE80/ISE80 1229
Dimensions
38.6
56.1
7.5 25.2 40
360.3
36 x n pcs. + 4 x (n pcs. – 1)
36
360.3
& &
Switches
Sensors
Switches
Sensors
67 or more
4 x R3
or less 4 x R3 or less
For more product options and details see our specific catalogues or on-line information.
1230 Series ZSE80/ISE80 – 2-colour Display, Digital Pressure Switch for Fluids
Dimensions
38.6
50
7.5 24.2 40
51.2
71.1
Panel-cut dimensions
360.3
36 x n pcs. + 4 x (n pcs. – 1)
Sensors
Switches
360.3
Sensors
36
Switches
& &
4 x R3 or less 4 x R3 or less
2-colour Display, Digital Pressure Switch for Fluids – Series ZSE80/ISE80 1231
Wiring
Internal Circuits and Wiring Examples
-N -P -A
NPN (1 output) PNP (1 output) NPN (2 outputs)
Load
Main circuit
Main circuit
Main circuit
Load
+ 12 to Black OUT + 12 to + 12 to
Black OUT – 24 VDC – 24 VDC Black OUT1 Load – 24 VDC
Load
White OUT2
-B -R -R/-S
PNP (2 outputs) NPN (2 outputs) + NPN (2 outputs) +
Analog voltage output Auto-shift input
Main circuit
Main circuit
Load Load
Black OUT1 + 12 to + 12 to + 12 to
24 VDC Black OUT1 Load – Black OUT1 Load – 24 VDC
Load – 24 VDC
White OUT2 White OUT2 White OUT2
Load Load
-S -T -T/-V
NPN (2 outputs) + PNP (2 outputs) + PNP (2 outputs) +
Analog current output Analog voltage output Auto-shift input
Main circuit
Main circuit
Load Load
+ 12 to + 12 to Black OUT1 + 12 to
Black OUT1 Load – 24 VDC Black OUT1 Load – 24 VDC Load – 24 VDC
& &
White OUT2 White OUT2 White OUT2
Switches
Load Load Load
Sensors
Switches
Sensors
Blue DC (–) Blue DC (–) Blue DC (–)
-V
PNP (2 outputs) +
Analog current output
Brown DC (+)
+ 12 to
Black OUT1 Load – 24 VDC
White OUT2
Load
Blue DC (–)
Max. 80 mA
Residual voltage 1 V or less
For more product options and details see our specific catalogues or on-line information.
1232 Series PS1000/1100 – Air Checker Electronic Presssure Switch
Features
• Extremely Compact : 13W X 10H X 30L [mm].
• 2 wire switch: Applicable to either NPN or PNP output.
• Easy mounting Plug-in port for One-touch fittings.
• High visibility: A large LED indicator for high visibility.
• Wide calibration range: –0.1 to 0.45MPa is possible with one
pressure switch.
How to Order
PS 10 00 R06 L Q
30
30 3000
Wiring 25.5 Lead wire length
Load PRESS.-0.10to45MPa
Main
+ Main
+ MADE IN JAPAN
Integrated
display PFM 7 10 C4 B
Type
7 Integrated display
Output specification
Rated flow range (Flow rate range)
A 2 NPN outputs
10 0.2 to 10 (5) l/min B 2 PNP outputs
25 0.5 to 25 (12.5) l/min C 1 NPN output + Analogue (1 to 5 V)
50 1 to 50 (25) l/min D 1 NPN output + Analogue (4 to 20 mA)
11 2 to 100 (50) l/min E 1 PNP output + Analogue (1 to 5 V)
Note) Fluid: CO2
F 1 PNP output + Analogue (4 to 20 mA)
Flow adjustment valve G 1 NPN output + External input Note 3)
- None H 1 PNP output + External input Note 3)
S Yes Note 3) User can select from accumulated value
external reset, auto-shift and auto-shift zero.
Port size
Flow rate range Piping entry direction
Symbol Description
10 25 50 11 - Straight
F01 G1/8 L Bottom
F02 G1/4 Note) Different combinations
of piping entry
C4 ø4 (5/32") one-touch fitting directions for IN and
C6 ø6 one-touch fitting OUT side are available
C8 ø8 (5/16") one-touch fitting as made-to-order.
Remote
sensor unit PFM 5 10 C4 1
Sensors &
Type Switches
5 Remote sensor unit
For more product options and details see our specific catalogues or on-line information.
1234 Series PFM – 2-Colour Display Digital Flow Switch
Product Recommendation
PFM710-C4-B PFM710S-F01-F PFM711-F02-F PFM725-F01-B PFM750-C6-F Series AR - Air Regulator - page 1084
PFM710-C6-B PFM711-C6-B PFM711S-C6-B PFM725-F01-E-A PFM750-F01-B Series AF - Main Line Filter - page 1082
Series AW - Filter Regulator - page 1088
PFM710-C6-E PFM711-C6-E PFM711S-C6-E PFM725S-C6-B PFM750-F01-E Series ZSE/ISE0A - Digital pressure switch of air - page 1273
PFM710-F01-F PFM711-C6-F PFM711S-C8-B PFM725S-C8-B PFM750-F01-F Series VX2 - Direct Operated 2 Port Solenoid Valves - page 1457
PFM710S-C4-B PFM711-C8-B PFM711S-F02-B PFM725S-F01-B PFM750S-C6-E Series VXZ - Pilot Operated 2 Port Solenoid Valves - page 1451
Series KQ2 - Fittings - page 1184
PFM710S-C4-E PFM711-C8-F PFM711S-F02-F PFM725S-F01-F PFM750S-C6-F Series TU - Tubing - page 1223
PFM710S-C6L-F PFM711-F02-B PFM725-C6-B PFM750-C6B PFM750S-F01-B
PFM710S-F01-B-M PFM711-F02-E PFM725-C6-F PFM750-C6E PFM750S-F01-F
Piping variations
S S
1 1
2
Without
S 2 S
1 1
2 2
1
1
IN IN
IN IN
flow adjustment
S S
1 S 1
S 2 1 2
With
1 2
2
Sensors &
Switches
IN
IN 1
1
IN
IN
Mounting
Bottom mounting
Bracket
Panel mount
DIN rail
Through-hole
mounting
2-Colour Display Digital Flow Switch – Series PFM 1235
PFM3 0 3 L
Type
3 Remote display unit
Input specification
Symbol Content Applicable remote type sensor unit
Option 2
0 Voltage input PFM5(S)--1
- None
1 Current input PFM5(S)--2
With sensor connector
Output specification
0 2 NPN outputs + 1 to 5 V output
1 2 NPN outputs + 4 to 20 mA output Sensor connector
F (e-con connector)
2 2 NPN outputs + External input Note)
3 2 PNP outputs + 1 to 5 V output ZS-28-C-1
4 2 PNP outputs + 4 to 20 mA output
5 2 PNP outputs + External input Note)
Note) User can select from accumulated value
Note) Connector is not connected, but shipped together.
external reset, auto-shift and auto-shift zero.
Option 1
- None
Power supply / Output connector
Optional part numbers for PFM7 and PFM5
Sensors &
Switches
Panel mount adapter A
Panel mount
Panel mount adapter B
Bracket
adapter
ZS-33-M (for without flow ZS-33-JS
adjustment valve) (for with flow
adjustment valve)
Panel
Mounting bracket
ZS 33 R
Stations DIN Rail
Bracket
ZS-33-MS (for with flow 1 1 station Mounting
2 2 stations Bracket
adjustment valve) 3 3 stations
4 4 stations
5 5 stations
For more product options and details see our specific catalogues or on-line information.
1236 Series PFM – 2-Colour Display Digital Flow Switch
Specifications PFM7
Specifications PFM5
Model PFM510 PFM525 PFM550 PFM511
Dry air, N2, Ar, CO2
Applicable fluid
(Air quality grade is JIS B8392.1-1, 1.2 to 1.6.2 and ISO8573.1-1, 1.2 to 1.6.2.)
Rated flow range Note) Dry air, N2, Ar 0.2 to 10 l/min 0.5 to 25 l/min 1 to 50 l/min 2 to 100 l/min
(Flow rate range) CO2 0.2 to 5 l/min 0.5 to 12.5 l/min 1 to 25 l/min 2 to 50 l/min
Accuracy 3%F.S. or less
Repeatability ±1%F.S. or less (Fluid: Dry air)
Pressure characteristics ±5%F.S. or less (based on 0.35 MPa)
±2%F.S. (15 to 35ºC)
Temperature characteristics
±5%F.S. (0 to 50ºC)
Operating pressure range –100 kPa to 750 kPa
Rated pressure range –70 kPa to 750 kPa
Proof pressure 1 MPa
50 msec or 1 s (with response time selection function: 1 s at no-voltage input)
Response time
Æ Refer to the internal circuits and wiring examples on page 16.
Vibration resistance Without orifice: 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.
With orifice: 10 to 150 Hz with a 1.5 mm amplitude or 19.6 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.
Impact resistance 490 m/s2 in X, Y, Z directions 3 times each
Note: Flow rate unit is based on standard conditions (20C, 1 atm, 65% RH).
Specifications PFM3
Model PFM3
Note 1) Dry air, N2, Ar 0.2 to 10.5 l/min 0.5 to 26.3 l/min 1 to 52.5 l/min 2 to 105 l/min
Displayed flow range
CO2 0.2 to 5.2 l/min 0.5 to 13.1 l/min 1 to 26.2 l/min 2 to 52 l/min
Minimum unit setting 0.01 l/min 0.1 l/min 0.1 l/min 0.1 l/min
Accumulated pulse flow rate exchange value 0.1 l/pulse 0.1 l/pulse 0.1 l/pulse 1 l/pulse
Real-time flow rate l/min, CFM x 10-2
Indication unit
Accumulated flow l, ft3 x 10-1
Accumulated flow range 1999999 l
Power supply voltage 24 VDC (ripple ±10% or less) (With polarity protection)
Current consumption 50 mA or less
Sensors &
Switches
Sensor input PFM30: Voltage input 1 to 5 VDC (input impedance: 1 MΩ)
Number of inputs: 1 PFM31: Current input 4 to 20 mADC (input impedance: 250 Ω)
Hysteresis Hysteresis mode: Variable, Window comparator mode: Variable
NPN or PNP open collector output: 2 outputs
Switch output Maximum load current: 80 mA, max. load voltage 30 VDC (at NPN output),
Residual voltage 1 V or less (at load current 80 mA), With short-circuit protection
Accumulated pulse output NPN or PNP open collector output (Same as switch output)
Response time 1 s (50 ms, 0.5 s, 2 s can be selected.)
Repeatability ±0.1%F.S., Analogue output accuracy: ±0.3%F.S.
Voltage output: 1 to 5 VDC (0 l/min to max. rated flow rate value)
Output impedance: Approx. 1 kΩ, Accuracy: ±1%F.S. or less (relative to display value)
Analogue output Current output: 4 to 20 mADC (0 l/min to max. rated flow rate value)
Max. load impedance: 600 Ω (at 24 VDC), Min. load impedance: 50 Ω
Accuracy: ±1%F.S. (relative to display value)
Display accuracy ±0.5%F.S. ±1 digit
Display method 3+1/2-digit, 7-segment LED 2-color display (Red/Green) Sampling cycle: 10 times/sec
Status LED’s OUT1: Illuminates when output is turned ON (Green). OUT2: Illuminates when output is turned ON (Red).
External input No-voltage input (Reed or Solid state), LOW level input 30 msec or more, LOW level 0.4 V or less
Enclosure IP40
Operating temperature range Operating: 0 to 50ºC Stored: –10 to 60ºC (with no freezing and condensation)
Weight 30 g (Without cable) 85 g (With cable)
Note 1) Select the sensor to connect in the initial setting. If CO2 is selected as the operating fluid, the value is 1/2 on the maximum side.
For more product options and details see our specific catalogues or on-line information.
1238 Series PFM – 2-Colour Display Digital Flow Switch
Dimensions PFM7
PFM7-C4/C6/C8
[mm]
28
One-touch fitting
Applicable tube O.D.
A B
ø8 (5/16") 68 96
2 x 2.6 depth 5
OUT1 OUT2
IN OUT
43
(34.2)
13
1 IN
3
2 x one-touch fitting
18
2 x 3.4
A
48
18
PFM7S-C4/C6/C8
28 20
8
3 x 2.6 depth 5
OUT1 OUT2
Sensors &
10.2
Switches
DC (–) DC (+)
1
IN OUT
43
(34.2)
3
13
1 IN
18
2 x one-touch fitting
2 x 3.4
B
76
58
48
18
2-Colour Display Digital Flow Switch – Series PFM 1239
Dimensions
58
29.9
28
1 IN 1 IN 1 IN
18
18 x n pcs. + 34.4
1.2
18
48
36
28
48
34
26
18
Sensors &
4
Switches
x
3.
4
For more product options and details see our specific catalogues or on-line information.
1240 Series PFM – 2-Colour Display Digital Flow Switch
Dimensions PFM5
PFM5-C4/C6/C8 [mm]
28 One-touch fitting
Applicable tube O.D.
A B
2 x 2.6 depth 5
OUT1 OUT2
10.2
DC (–) DC (+)
IN OUT
43
(34.2)
13
1 IN
2 x one-touch fitting
3
18
2 x 3.4
A
48
FLOW SENSOR
18
POWER FLOW
PFM5S-C4/C6/C8
28 20
8
3 x 2.6 depth 5
OUT1 OUT2
Sensors &
10.2
Switches
DC (–) DC (+)
51.5 (Max.58.5)
IN OUT
43
(34.2)
3
13
1 IN
18
2 x one-touch fitting
2 x 3.4
B
76
58
48
FLOW SENSOR
18
POWER FLOW
2-Colour Display Digital Flow Switch – Series PFM 1241
Dimensions
58
FLOW SENSOR
29.9
28
POWER FLOW
1 IN 1 IN 1 IN
18
1.2
48 18 x n pcs. + 34.4
36 18
28
FLOW SENSOR
FLOW
FLOW
FLOW
34
26
18
POWER FLOW
Sensors &
Switches
FLOW SENSOR
FLOW SENSOR
FLOW SENSOR
48
4
x
3.
POWER
POWER
POWER
For more product options and details see our specific catalogues or on-line information.
1242 Series PFM – 2-Colour Display Digital Flow Switch
Dimensions PFM3
31 3 30
20 0.1
2 x M3 x 0.5 Power supply / Output connector
Thread depth 4
1.5
10
Sensor connector
1.5 3.2
8.2
30
With bracket
20
46
4.2
10
15
40
31.5
26.5
7.2
1.6
22
35
41
Bracket View A
Panel thickness
8.5 dimension: 0.5 to 6
Dimensions PFM3
1 pc.
24 or more
31–0.4
0
31 x n pcs. + 3.5 x (n pcs. – 1)
31–0.4
31–0.4
0
4 x R2 or less 4 x R2 or less
Sensors &
Switches
4 x R2 or less
For more product options and details see our specific catalogues or on-line information.
1244 Series PF2A – Digital Flow Switch for Air
PF2A7 10 F 01 67
PF2A710, PF2A750
02 1/4
03 3/8 PF2A711, PF2A721
Flow rate range Output specifications 04 1/2 PF2A751
Thread type
10 1 to 10 l/min Symbol Output specifications Applicable model
F G
50 5 to 50 l/min NPN open collector PF2A710, PF2A750
27 2 outputs
11 10 to 100 l/min PF2A711, PF2A721, PF2A751
21 20 to 200 l/min PNP open collector PF2A710, PF2A750
67
51 50 to 500 l/min 2 outputs PF2A711, PF2A721/PF2A751
(Accessories)
Lead wire with connector (3m): ZS-37-A
Stocked items for fast delivery
(Related Products)
PF2A710-F01-27 PF2A750-F02-27 PF2A711-F03-67 PF2A721-F03-67N Series AR - Air Regulator - page 1084
Series AF - Main Line Filter - page 1082
PF2A710-F01-67 PF2A750-F02-27N PF2A711-F03-67N PF2A751-F04-27N
Series AW - Filter Regulator - page 1088
PF2A710-F02-67 PF2A750-F02-67 PF2A721-F03-27N PF2A751-F04-67 Series ZSE/ISE0A - Digital Pressure Switch of Air - page 1273
PF2A710-F02-67N PF2A750-F02-67N PF2A721-F03-67 PF2A751-F04-67N Series VNB - 2 Port Air Operated Valves - page 1466
Series VXZ - Pilot Operated 2 Port Solenoid Valves - page 1451
Series KQ2 - Fittings - page 1184
Series TU - Tubing - page 1223
Specifications
Model PF2A710 PF2A750 PF2A711 PF2A721 PF2A751
Measured fluid Air, Nitrogen
Flow rate measurement range 0.5 to 10.5 l/min 2.5 to 52.5 l/min 5 to 105 l/min 10 to 210 l/min 25 to 525 l/min
Set flow rate range 0.5 to 10.5l /min 2.5 to 52.5 l/min 5 to 105 l/min 10 to 210 l/min 25 to 525 l/min
Flow rate measuring range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min
Minimum set unit 0.1 l/min 0.5 l/min 1 l/min 2 l/min 5 l/min
Accumulated pulse flow rate exchange value (Pulse width: 50 ms) 0.1 l/pulse 0.5 l/pulse 1 l/pulse 2 l/pulse 5 l/pulse
–2
Note 1) Real-time flow rate l/min, CFM x 10 l/min, CFM x 10–1
Display unit
Accumulated flow l, ft3 x 10–1
Sensors &
Switch output
Maximum load current: 80 mA
PNP open collector Internal voltage drop: 1.5 V or less (With load current of 80 mA); Two outputs
Accumulated pulse output NPN or PNP open collector (same as switch output)
Indicator light Lights up when output is ON OUT1: Green; OUT2: Red
Response time 1sec. or less
Hysteresis Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 4)
Power supply voltage 12 to 24 VDC (Ripple 10% or less)
Enclosure IP65
Resistance
Operating temperature range Operating: 0 to 50ºC, Stored: –25 to 85ºC (No condensation or freezing)
Withstand voltage 1000 VAC for 1 min. between external terminal and case
Insulation resistance 50 MΩ (500 VDC) between external terminal and case
Note 1) Flow rate display can be switched between the basic condition of 0ºC, 101.3 kPa and the standard condition (ANR) of 20ºC, 101.3 kPa, and 65% RH.
Note 2) Without lead wire.
Note 3) Switch output and accumulated pulse output can be selected during initial setting.
Note 4) Window comparator mode — Since hysteresis will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits or more.
(In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.)
Digital Flow Switch for Air – Series PF2A 1245
Dimensions
Features Integrated Display Type for Air
PF2A710/750
(44.3)
42
4
2-ø3.4
43
Flow direction
67 98
58 6 82
17 1.6 60
FLOW SWITCH
UP
54
44
SET
OUT1 OUT2
DOWN
FOR AIR
2-Port size 24
4-ø4.5 40
50
PF2A711/721/751
(44.3)
Sensors &
Switches
1 2
Flow direction
64 Pin no. Pin description
23 116 1 DC (+)
1.6 88 2 OUT2
3 DC (–)
4 OUT1
FLOW SWITCH
UP
34
SET
54
44
OUT1 OUT2
DOWN
FOR AIR
For more product options and details see our specific catalogues or on-line information.
1246 Series PF2A – Digital Flow Switch for Air
PF2A5 10 F 01
PF2A710, PF2A750
2 Output for display unit + analog output (4 to 20 mA) 02 1/4
03 3/8 PF2A711, PF2A721
Flow rate range 04 1/2 PF2A751
Wiring specification
10 1 to 10 l/min
50 5 to 50 l/min – 3m lead wire with connector
Thread type N Without lead wire
11 10 to 100 l/min
F G
21 20 to 200 l/min
51 50 to 500 l/min
(Accessories)
Lead wire with connector (3m): ZS-37-A
Stocked items for fast delivery
(Related Products)
PF2A510-F01N-2 PF2A511-F03-2 PF2A521-F03-2 PF2A551-F04-2 Series AR - Air Regulator - page 1084
Series AF - Main Line Filter - page 1082
PF2A510-F02 PF2A511-F03N PF2A521-F03N PF2A551-F04N Series AW - Filter Regulator - page 1088
PF2A510-F02N PF2A511-F03N-1 PF2A521-F03N-1 PF2A551-F04N-1 Series ZSE/ISE0A - Digital Pressure Switch of Air - page 1273
PF2A551-F04N-2 Series VNB - 2 Port Air Operated Valves - page 1466
PF2A550-F02 PF2A511-F03N-2 PF2A521-F03N-2
Series VXZ - Pilot Operated 2 Port Solenoid Valves - page 1451
PF2A550-F02N PF2A521-F03 PF2A551-F04 Series KQ2 - Fittings - page 1184
PF2A550-F02N-2 PF2A521-F03-1 PF2A551-F04-1 Series TU - Tubing - page 1223
Specifications
Operating temperature range Operating: 0 to 50ºC, Stored: –25 to 85ºC (No condensation or freezing)
Withstand voltage 1000 VAC for 1 min. between external terminal and case
Insulation resistance 50 MΩ (500 VDC) between external terminal and case
Weight Note 3) 200 g 240 g
Port size [G] 1/8, 1/4 3/8 1/2
Note 1) The system accuracy when combined with PF2A3.
Note 2) Output system can be selected during initial setting.
Note 3) Without lead wire. (Add 20 g for the types of analog output whether voltage or current output selected.)
Note 4) Flow rate unit measured under the following conditions: 0˚C and 101.3 kPa.
Digital Flow Switch for Air – Series PF2A 1247
Dimensions
Features Remote Type Sensor Unit for Air
PF2A510/550
(46.3)
A
[mm]
Output specifications A B
4
98
B 82
23 60
1.6 48.2
34
54
44
PF2A511/521/551
(46.3)
[mm]
Output specifications A B
Pulse output only 48 62
Pulse output + Analogue output 58 72
Sensors &
Switches
A
3 4
34
1 DC (+)
2 NC/Analogue output
3 DC (–)
4 OUT
2-Port size 30 4-ø4.5 40
50
For more product options and details see our specific catalogues or on-line information.
1248 Series PF2A – Digital Flow Switch for Air
Features
Features
• Displays flow information.
• Works with remote sensor units.
• Panel mounting construction.
• Clear LED indication.
• Two independent digital outputs.
• Output modes instantaneous flow, total flow and counting pulse.
• Integrated LED display can show metric or imperial units.
How to Order
PF2A3 0 1 A
Flow rate range Mounting
A Panel mounting
Symbol Flow rate range Type for sensor unit
1 to 10 l/min PF2A510
0 Output specifications
5 to 50 l/min PF2A550
10 to 100 l/min PF2A511 Symbol Output specifications Applicable model
1 20 to 200 l/min PF2A521 0 NPN open collector 2 outputs PF2A300/310
50 to 500 l/min PF2A551 1 PNP open collector 2 outputs PF2A301/311
Related Products
Product Recommendation
Series AR - Air Regulator - page 1084
Series AF - Main Line Filter - page 1082
Stocked items for fast delivery Series AW - Filter Regulator - page 1088
Series ZSE/ISE0A - Digital Pressure Switch of Air - page 1273
Series VNB - 2 Port Air Operated Valves - page 1466
PF2A301-A PF2A310-A PF2A311-A
Series VXZ - Pilot Operated 2 Port Solenoid Valves - page 1451
Series KQ2 - Fittings - page 1184
Series TU - Tubing - page 1223
Specifications
Model PF2A300/301 PF2A310/311
Flow rate measurement range Note 1) 0.5 to 10.5 l/min 2.5 to 52.5 l/min 5 to 105 l/min 10 to 210 l/min 25 to 525 l/min
Set flow rate range Note 1) 0.5 to 10.5 l/min 2.5 to 52.5 l/min 5 to 105 l/min 10 to 210 l/min 25 to 525 l/min
Minimum set unit Note 1) 0.1 l/min 0.5 l/min 1 l/min 2 l/min 5 l/min
Accumulated pulse flow rate exchange
value (Pluse width: 50 ms) Note 1) 0.1 l/pulse 0.5 l/pulse 1 l/pulse 2 l/pulse 5 l/pulse
Note 2)
Real-time flow rate l/min, CFM x 10–2 l/min, CFM x 10–1
Display unit
Accumulated flow l, ft3 x 10–1
Accumulated flow range 0 to 999999 l
Linearity Note 3) ±5% F.S.
Sensors &
Switches
Switch output
Maximum load current: 80 mA
PNP open collector (PF2A301, PF2A311) Internal voltage drop: 1.5 V or less (With load current of 80 mA)
Output
2 outputs
Accumulated pulse output NPN or PNP open collector (same as switch output)
Display 3-digit, 7-segment LED
Indicator light Lights up when output is ON OUT1: Green; OUT2: Red
Power supply voltage 12 to 24 VDC (Ripple 10% or less)
Response time 1 sec. or less
Hysteresis Hysteresis mode: Variable (can be set from 0), Window comparator mode: Fixed (3 digits) Note 5)
Enclosure IP40
Resistance
Operating temperature range Operating: 0 to 50ºC, Stored: –25 to 85ºC (No condensation or freezing)
Withstand voltage 1000 VAC for 1 min. between external terminal and case
Insulation resistance 50 MΩ (500 VDC) between external terminal and case
Note 1) The flow rate measurement range can be modified depending on the setting.
Note 2) Flow rate display can be switched between the basic condition of 0ºC, 101.3 kPa and the standard condition (ANR) of 20ºC, 101.3 kPa, and 65% RH.
Note 3) The system accuracy when combined with PF2A5.
Note 4) Switch output and accumulated pulse output can be selected during initial setting.
Note 5) Window comparator mode — Since hysteresis will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits or more.
(In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.)
Digital Flow Switch for Air – Series PF2A 1249
PF2A3-A
Panel mounting type
1 2 3 4
+0.5
0
19.4
36
5 6 7 8
40.3 41.8
4.3 40
A
40
UNIT
RESET
SET
Analogue output
1 to 5 VDC 4 to 20 mADC
5 20
Sensors &
Switches
Analog output [mA]
Analog output [V]
1 4
Min. measured Max. measured Real-time Min. measured Max. measured Real-time
flow rate value flow rate value flow rate [l/min] flow rate value flow rate value flow rate [l/min]
For more product options and details see our specific catalogues or on-line information.
1250 Series PF2A – Digital Flow Switch for Air
Port size
How to Order Flow rate [l/min]
Wiring specification Symbol Port
Applicable
size 3000 6000 12000 model
– 3m lead wire with connector
(Accessories)
Lead wire with connector (3m): ZS-37-A
Stocked items for fast delivery
(Related Products)
PF2A703H-F10-28 PF2A703H-F10-69N PF2A712H-F20-29N Series AR - Air Regulator - page 1084
Series AF - Main Line Filter - page 1082
PF2A703H-F10-29N PF2A706H-F14-29N PF2A712H-F20-68 Series AW - Filter Regulator - page 1088
PF2A703H-F10-68 PF2A706H-F14-68N PF2A712H-F20-69 Series ZSE/ISE0A - Digital Pressure Switch of Air - page 1273
Series VNB - 2 Port Air Operated Valves - page 1466
PF2A703H-F10-68N PF2A706H-F14-69 PF2A712H-F20-69N Series VXZ - Pilot Operated 2 Port Solenoid Valves - page 1451
PF2A703H-F10-69 PF2A706H-F14-69N Series KQ2 - Fittings - page 1184
Series TU - Tubing - page 1223
Specifications
Model PF2A703H PF2A706H PF2A712H
Measured fluid Dry air
Detection type Heater type
Flow rate measuring range Note 1) 150 to 3000 l/min 300 to 6000 l/min 600 to 12000 l/min
Minimum setting unit Note 1) 5 l/min 10 l/min
Real-time flow rate l/min, CFM
Sensors &
Display unit
Switches
Dimensions
Features
PF2A703H/706H/712H
1 2
H
D
E
F B
A
2-G 60 C
Model A B C D E F G H I J
PF2A703H 55 160 40 92 67 55 1" 36 M5 x 0.8 8
PF2A706H 65 180 45 104 79 65 11/2" 46 M6 x 1 9
PF2A712H 75 220 55 114 89 75 2" 56 M6 x 1 9
Analogue output
1 to 5 VDC 4 to 20 mADC
Sensors &
5 20 Switches
Analog output [mA]
Analog output [V]
1 4
Min. measured Max. measured Real-time Min. measured Max. measured Real-time
flow rate value flow rate value flow rate [l/min] flow rate value flow rate value flow rate [l/min]
PF2A706H--28 PF2A706H--29
PF2A706H--68 300 6000 PF2A706H--69 300 6000
For more product options and details see our specific catalogues or on-line information.
1252 Series PF3W – 3-Colour Display Digital Flow Switch for Water
How to Order
Digital Flow Switch for Water
Remote sensor unit Output specification/Temperature sensor
OUT1 OUT2
Symbol Temperature sensor
Flow rate Temperature
1 Analogue 1 to 5 V —
None
2 Analogue 4 to 20 mA —
1T Analogue 1 to 5 V Analogue 1 to 5 V With temperature sensor
Remote
sensor unit PF3W 5 04 F 03 1T N
Integrated
display PF3W 7 04 F 03 BT N M
Type
5 Remote sensor unit
Thread type
7 Integrated display Integrated display/Unit specification
F G
Instantaneous Accumulated
Rated flow range (Flow range) Symbol Temperature
flow rate flow
Symbol Rated flow range M l/min l °C
04 0.5 to 4 l/min Port size G gal/min gal °C
20 2 to 16 l/min Rated flow range F gal/min gal °F
Port
40 5 to 40 l/min Symbol size J l/min °F
04 20 40 11 l
11 10 to 100 l/min
03 3/8 — — Note) G, F, J: Made to Order
Flow adjustment valve 04 1/2 — — Reference: 1 [l/min] 0.2642 [gal/min]
With/without flow Rated flow rate 06 3/4 — — 1 [gal/min] 3.785 [l/min]
Symbol 10 1 °F = 9/5°C + 32
adjustment valve 04 20 40 11 — — —
Sensors &
Switches
— None
S Yes — Integrated display
Lead wire
100 l/min type is not available with flow
Output specification/ — N
adjustment valve.
Temperature sensor With lead wire with M8 Without lead wire
OUT1 OUT2 Temperature connector with M8
Note 1) External input: Symbol (3 m) connector
Flow rate Flow rate Temperature sensor
The accumulated
value, peak
A NPN NPN —
value, and B PNP PNP —
bottom value can C NPN Analogue 1 to 5 V —
be reset. D NPN Analogue 4 to 20 mA —
None
Note 2) For units with E PNP Analogue 1 to 5 V —
temperature F PNP Analogue 4 to 20 mA —
sensor, OUT2 G NPN External input Note 1) —
can be set as H PNP External input Note 1) —
either tempera- AT NPN (NPN) Note 2) NPN
ture output or
BT PNP (PNP) Note 2) PNP
flow rate output. With
Setting when
CT NPN (Analogue 1 to 5 V) Note 2) Analogue 1 to 5 V
temperature
shipped is for DT NPN (Analogue 4 to 20 mA) Note 2) Analogue 4 to 20 mA sensor
temperature ET PNP (Analogue 1 to 5 V) Note 2) Analogue 1 to 5 V
output. FT PNP (Analogue 4 to 20 mA) Note 2) Analogue 4 to 20 mA
3-Colour Display Digital Flow Switch for Water – Series PF3W 1253
How to Order
Digital Flow Switch for PVC Piping
Remote
sensor unit PF3W 5 11 U 25 1 N
Integrated
display PF3W 7 11 U 25 A N M
Type
5 Remote sensor unit
Integrated display/Unit specification
7 Integrated display
Instantaneous Accumulated
Symbol Temperature
Rated flow range flow rate flow
(Flow range) M l/min l °C
G gal/min gal °C
Symbol Rated flow range
F gal/min gal °F
11 10 to 100 l/min
J l/min l °F
Connection type Note) G, F, J: Made to Order
U PVC pipe Reference: 1 [l/min] 0.2642 [gal/min]
1 [gal/min] 3.785 [l/min]
°F = 9/5°C + 32
PVC pipe O.D.
Symbol Port size
25 25A Lead wire
— N
Integrated display/Output specification With lead wire with M8 Without lead wire
connector with M8
Symbol OUT1 OUT2 (3 m) connector
A NPN NPN
B PNP PNP
C NPN Analogue 1 to 5 V
D NPN Analogue 4 to 20 mA
E PNP Analogue 1 to 5 V
F PNP Analogue 4 to 20 mA
G NPN External input
H PNP External input
External input: The accumulated value,
peak value, and bottom
value can be reset.
Sensors &
Switches
For more product options and details see our specific catalogues or on-line information.
1254 Series PF3W – 3-Colour Display Digital Flow Switch for Water
How to Order
Digital Flow Monitor for Water
PF3W 3 0 A M V
Type
3 Remote monitor unit Option 1
For remote sensor units, select the — None
analog output 1 to 5 V type. Panel mount adapter
Applicable sensors: PF3W5--1(T)
Panel mount adapter
Output specification
Symbol OUT1 OUT2
A NPN NPN T
B PNP PNP Mounting screw
C NPN Analogue 1 to 5 V (M3 x 8 L)
Waterproof seal (accessory)
D NPN Analogue 4 to 20 mA
(accessory)
E PNP Analogue 1 to 5 V Panel
F PNP Analogue 4 to 20 mA Front protective cover + Panel mount adapter
G NPN External input Front protective cover Panel mount adapter
H PNP External input
J Analogue 1 to 5 V Analogue 1 to 5 V Mounting screw
(M3 x 8 L)
K Analogue 4 to 20 mA Analogue 4 to 20 mA
(accessory)
In combination with remote sensor unit with temperature V
sensor, only OUT2 can be set for temperature sensor
output.
Lead wire Waterproof seal
(accessory) Panel
With power supply/output connection lead wire (2 m)
Product Recommendation
Stocked items for fast delivery (for PF3W7) Stocked items for fast delivery (for PF3W7 of PVC)
Related Products
(Accessories)
Lead wire with M8 connector ZS-40-A
(Related Products)
Series ZSE/ISE80 - Digital Pressure Switch for Fluids - page 1290
Series VNB - 2 Port Air Operated Valves - page 1466
Series VXZ - Pilot Operated 2 Port Solenoid Valves - page 1451
Series PA - Process Pump - page 1473
Series KQ2 - Fittings - page 1184
Series TU - Tubing - page 1223
3-Colour Display Digital Flow Switch for Water – Series PF3W 1255
Specifications
Integrated Display
Model PF3W704 PF3W720 PF3W740 PF3W711
Applicable fluid Water and ethylene glycol aqueous solution (with viscosity of 3 mPa·s [3 cP] or less)
Rated flow range 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 10 to 100 l/min
Display flow range 0.35 to 5.50 l/min 1.7 to 22.0 l/min 3.5 to 55.0 l/min 7 to 140 l/min
Minimum setting unit 0.01 l/min 0.1 l/min 1 l/min
Conversion of accumulated pulse (Pulse width: 50 ms) 0.05 l/pulse 0.1 l/pulse 0.5 l/pulse 1 l/pulse
Accumulated flow range 99999999.9 l 999999999 l
Switch output NPN or PNP open collector output
Analogue output Voltage output: 1 to 5 V Output impedance: 1 kΩ
Response time 0.5s / 1s / 2s (linked with the switch output)
Accuracy Display value: ±3% F.S. Analogue output: ±3% F.S.
Remote Display
Model PF3W30
0.35 to 4.50 l/min 1.7 to 18.0 l/min 3.5 to 45.0 l/min 7 to 112 l/min
Display flow range
(Flow under 0.35 l/min is displayed as “0.00”) (Flow under 1.7 l/min is displayed as “0.0”) (Flow under 3.5 l/min is displayed as “0.0”) (Flow under 7 l/min is displayed as “0”)
Set flow range 0.35 to 4.50 l/min 1.7 to 18.0 l/min 3.5 to 45.0 l/min 7 to 112 l/min
Minimum setting unit 0.01 l/min 0.1 l/min 1 l/min
Conversion of accumulated pulse 0.05 l/pulse 0.1 l/pulse 0.5 l/pulse 1 l/pulse
Accumulated flow range 99999999.9 l 999999999 l
Switch output NPN or PNP open collector output
Analogue output Voltage output: 1 to 5 V Output impedance: 1 kΩ; Output current: 4 to 20 mA
Response time 1s / 2s (linked with the switch output)
Accuracy Display value: ±0.5% F.S. Analogue output: ±0.5% F.S.
Operating temperature range 0 to 50°C (with no freezing and condensation)
Temperature characteristics ±0.5% F.S. (25°C reference)
Power supply voltage 12 to 24 VDC ±10%
Sensors &
Switches
Accessories and Replacement Kits
PF3W30 Accessories
For more product options and details see our specific catalogues or on-line information.
1256 Series PF3W – 3-Colour Display Digital Flow Switch for Water
Flow Characteristics
PF3W704/504 PF3W720/520
0.04 0.04
Pressure loss [MPa]
0.02 0.02
0.01 0.01
0 0
0.0 1.0 2.0 3.0 4.0 0 2 4 6 8 10 12 14 16
Flow rate [l/min] Flow rate [l/min]
PF3W740/540 PF3W711/511
0.04 0.04
Pressure loss [MPa]
0.03 0.03
0.02 0.02
0.01 0.01
0 0
0 5 10 15 20 25 30 35 40 0 20 40 60 80 100
Flow rate [l/min] Flow rate [l/min]
4.0 40
ΔP = 0.5 MPa ΔP = 0.4 MPa
ΔP = 0.4 MPa 10.0 30
ΔP = 0.3 MPa
ΔP = 0.3 MPa ΔP = 0.2 MPa
2.0 20
ΔP = 0.2 MPa 5.0
ΔP = 0.2 MPa ΔP = 0.1 MPa
10
ΔP = 0.1 MPa
ΔP = 0.1 MPa
Sensors &
0 0 0
Switches
0 2 4 5 0 2 4 5 0 1 2 3 4 5 6 7 8
Number of rotations [rotations] Number of rotations [rotations] Number of rotations [rotations]
ΔP: Pressure differential between the front and the rear of product ΔP: Pressure differential between the front and the rear of product ΔP: Pressure differential between the front and the rear of product
90
80
70
60
50
40
30 Measurable within this range
20
10
0
0 10 20 30 40 50 60 70 80 90
Aqueous solution temperature [°C]
3-Colour Display Digital Flow Switch for Water – Series PF3W 1257
Dimensions
PF3W704/720/740/711 K L
P
Integrated display
x
4
N
(35.5) 42
H
IN OUT
Connector
pin number
Example Pin no. Pin name
1 DC (+) AA
3 1 Y D
2 OUT2 A 1.4
3 DC (–) J E
4 2
4 OUT1 50 F
W
30
B
V
2 x piping port
S T Z
4
x
G
W
X
PF3W504/520/540/511
Remote sensor unit K L
P
x
4
N
H 42
(35.5)
IN OUT
Sensors &
AA Switches
A Y DD
J E
F
30
W
B
2 x piping port
S T Z
4
U
x
G
W
X
[mm]
Port size Bracket dimensions
Model
[Rc, NPT, G]
A AA B D DD E F G H J K L N P
S T U V W WX Y Z
PF3W704/504 3/8 70 50 30 60 45.6 40.6 15.2 24 14 35 26 18 13.6 ø2.7 depth 14 24 22 32 40 50 4.5 5 1.5
PF3W720/520 3/8, 1/2 78 54 30 60 45.6 40.6 15.2 27 18 39 30 18 13.6 ø2.7 depth 12 28 22 32 40 50 4.5 5 1.5
PF3W740/540 1/2, 3/4 98 71 38 68 53.6 48.6 19.2 32 28 49 35 28 16.8 ø2.7 depth 12 34 30 42 48 58 4.5 5 1.5
PF3W711/511 3/4, 1 124 92 46 77 62.6 57.6 23.0 41 42 63 48 28 18.0 ø3.5 depth 14 44 36 48 58 70 5.5 7 2.0
For more product options and details see our specific catalogues or on-line information.
1258 Series PF3W – 3-Colour Display Digital Flow Switch for Water
Dimensions
PF3W704/720/740/711--T PF3W504/520/540/511--T
Integrated display: With temperature sensor Remote sensor unit: With temperature sensor
AA 11 AA 11
A A
[mm]
Model A AA
PF3W704/504--T 81 50
PF3W720/520--T 89 54
PF3W740/540--T 109 71
PF3W711/511--T 135 92
PF3W704S/720S/740S PF3W504S/520S/540S
Integrated display: With flow adjustment valve Remote sensor unit: With flow adjustment valve
K L K L
P
P
x
x
4
4
N
N
Q Q
B
B
Sensors &
Switches
AA F AA F
A A
D D
S T S T
[mm]
Q number Bracket dimensions
Model A AA B D F K L N P Q of rotations S T
PF3W704S/504S 104 50 63.6 (Max. 68.6) 70.2 34 58.5 18 13.6 ø2.7 depth 10 ø19 6 56.5 22
PF3W720S/520S 112 54 63.6 (Max. 68.6) 74.2 34 62.5 18 13.6 ø2.7 depth 10 ø19 6 60.5 22
PF3W740S/540S 142 71 75.25 (Max. 81) 94.5 44 79.0 28 16.8 ø2.7 depth 10 ø28 7 78.0 30
3-Colour Display Digital Flow Switch for Water – Series PF3W 1259
Dimensions
PF3W704S/720S/740S--T PF3W504S/520S/540S--T
Integrated display: With temperature sensor Remote sensor unit: With temperature sensor
and flow adjustment valve and flow adjustment valve
K K
AA 11 AA 11
A A
D D
S S
[mm]
Model A AA D K S
PF3W704S/504S--T 115 50 81.2 69.5 67.5
PF3W720S/520S--T 123 54 85.2 73.5 71.5
PF3W740S/540S--T 153 71 105.5 90.0 89.0 Sensors &
Switches
For more product options and details see our specific catalogues or on-line information.
1260 Series PF3W – 3-Colour Display Digital Flow Switch for Water
Dimensions
PF3W711-U25A
14
Integrated display
h
pt
de
63 28
5
3.
x
4
18
57 42
(35.5)
Connector
pin number IN OUT
Example
3 1
4 2 154 7 77 1.4
77 57.6
23
Pin no. Pin name
1 DC (+)
2 OUT2 70
46
30
58
3 DC (–)
4 OUT1
2 x 25A
59 36 2
4
x
5.
48
5
PF3W511-U25A
Remote sensor unit
IN OUT
Sensors &
Switches
62.6
3-Colour Display Digital Flow Switch for Water – Series PF3W 1261
Dimensions
40.1 (7.5)
Sensor connector (4P) 40
6 2.5
NC/IN
36.8
40
Power supply/
output connector (5P)
9.4 (2) 53
47
42.4
46.4
or
37.5
R1
4x
Sensors &
Switches
55 or more
For more product options and details see our specific catalogues or on-line information.