Kathrein - K 800 10122
Kathrein - K 800 10122
Dual Polarization X X
Half-power Beam Width 88° 88°
Adjust. Electr. Downtilt 0°– 10° 0°– 6°
set by hand or by optional RCU (Remote Control Unit)
Impedance 50 Ω
VSWR < 1.5
Isolation: Intrasystem > 30 dB
Isolation: Intersystem > 45 dB (806–960 // 1710–2180 MHz)
Intermodulation IM3 < –150 dBc (2 x 43 dBm carrier)
Max. power per input 500 W (at 50 °C ambient temperature) 250 W (at 50 °C ambient temperature)
Total power 1000 W (at 50 °C ambient temperature) 500 W (at 50 °C ambient temperature)
9°
7-16 7-16 7-16 7-16
10
10
dB
dB
3 3
0 0
Mechanical specifications
Horizontal Pattern Vertical Pattern
0°– 10° electr. downtilt Input 4 x 7-16 female (long neck)
Subject to alteration.
10
Rearside: 870 N (at 150 km/h)
dB
dB
3 3
9
Weight Units per
Type No. Description Remarks
approx. antenna
1917
1960
2000
2116
733 678 1 clamp Mast: 115 – 210 mm diameter 2.6 kg 2
733 679 1 clamp Mast: 210 – 380 mm diameter 4.0 kg 2
733 680 1 clamp Mast: 380 – 521 mm diameter 5.3 kg 2
850 10007 1 downtilt kit Downtilt angle: 0° – 11° 5.9 kg 1
The downtilt kit can only be used in combination with the clamps
type nos. 738 546, 850 10002, 850 10003.
Wall mounting: No additional mounting kit is needed.
35–42
and painting. The colour of the radome is light grey. scale
All screws and nuts: Stainless steel.
Grounding: The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded.
149
167
Environmental conditions: Kathrein cellular antennas are designed to operate under the environ-
106
88
mental conditions as described in ETS 300 019-1-4 class 4.1 E.
45
The antennas exceed this standard with regard to the following items:
– Low temperature: –55 °C 50
– High temperature (dry): +60 °C 103
180
Ice protection: Due to the very sturdy antenna construction and the 262
protection of the radiating system by the radome, the antenna remains Bottom view
operational even under icy conditions. (Dimensions refer to radome)
Environmental tests: Kathrein antennas have passed environmental tests as recommended
in ETS 300 019-2-4. The homogenous design of Kathrein’s antenna RCU 806–960 RCU
families use identical modules and materials. Extensive tests have been 806–960 –45° +45° 1710–2180
performed on typical samples and modules. –45° +45°
1710–2180
Layout of interface
Please note: As a result of more stringent legal regulations and judgements regarding product liability, we are
obliged to point out certain risks that may arise when products are used under extraordinary operating
conditions.
Subject to alteration.
The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby
respects the static mechanical load imposed on an antenna by wind at maximum velocity. Wind loads are
calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional
dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna
or even cause it to fall to the ground. These facts must be considered during the site planning process.
The installation team must be properly qualified and also be familiar with the relevant national safety
936.2900/c
regulations.
The details given in our data sheets have to be followed carefully when installing the antennas and
accessories.
The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers
must be obeyed.
1
2
2
➀ Adjustment wheel with twist-lock ➀ Thread for fixing the protective To set the downtilt angle exactly,
function. cap or the RCU (Remote Control you must look horizontally at the
➁ Downtilt spindle with integrated Unit). scale. The lower edge of the gear-
scale. ➁ Gearwheel for RCU power drive. wheel must be used for alignment.
0° – max.°
max.° – 0°
Remove the protective cap. Set downtilt angle by rotating the Screw on the protective cap again.
adjustment wheel.
For a description of RCU installation please refer to the respective data sheet.
Internet: www.kathrein.de 800 10122 Page 3 of 4
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973
General Instructions for Feederline Installation
on XXPol Panels with four Connectors
Please note: In order not to damage the interfaces, please make sure that only the right tools are used.
Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench
width.
Ventilation hole
Layout of interface:
– RF inputs / polarization
– Adjustment mechanism
– Frequency range
Protective cap covering
adjustment mechanism
Subject to alteration.
Start with the rearside located interfaces. After feederline installation the optional For a full description of RCU installation
remote control units (RCU) can be please refer to the respective data sheet.
Place the connector carefully and fix the
mounted.
936.2900/c