SIMOTICS Low-Voltage Motors


Distribution offering and 1LE0 option line

This technical brochure focuses on a selected motor


spectrum specifically defined for the distribution business
covering all main standard applications and industries

Edition
07/2014
© Siemens AG 2014

Additional information is provided in the following This brochure is only applicable


documents and/or links: in the following countries:

- SIMOTICS Low-voltage Motors ASEAN


Catalog D 81.1 · January 2012 - Republic of Indonesia
Article No.: E86060-K5581-A111-A4-7600 - Kingdom of Thailand
Catalog D 81.1 · 2013 - Malaysia
Article No.: E86060-K5581-A111-A6-7600 - Socialist Republic of Vietnam
- Republic of Singapore
- SIMOTICS GP 1LE0 Low-voltage Motors - Republic of the Philippines
Catalog D 81.5N 09.2011 - Republic of Korea
Article No.: E20001-K0369-C600-X-5D00
South America
- Energy saving/Energy-saving program SinaSave - Republic of Chile
Further information regarding energy savings and - Argentine Republic
the energy-saving program SinaSave can be found
at the following internet addresses: Middle East
www.siemens.com/sinasave - United Arab Emirates
www.siemens.com/energysaving - Kingdom of Saudi Arabia
- Islamic Republic of Pakistan
- Selection tool DT Configurator
The DT Configurator covers the product range of low- Africa
voltage motors and MICROMASTER 4 / SINAMICS invert- - Republic of South Africa
ers and converters as well as frequency converters for
SIMATIC ET 200 distributed I/O. The range of available South Asia
products is being continuously expanded. - People’s Republic of Bangladesh
The following information is provided for the individual
products:
• 2D/3D-model generator for motors and converters
• Data sheet generator
• Start-up calculation for motors
• Comprehensive product-specific documentation
www.siemens.com/dt-configurator

- Additional documentation
You will find all information material, such as brochures,
catalogs, manuals and operating instructions for standard
drive systems up-to-date on the Internet at the address
www.siemens.com/motors/printmaterial
You can order the listed documentation or download it
in common file formats (PDF, ZIP).

- Further information about


Drive Systems > Variable-Speed Drives, e.g.,
SINAMICS and Motors for Single-Axis Drives D 31
SINAMICS G130 Drive Converter Chassis Units D 11
SINAMICS G150 Drive Converter Cabinet Units
SINAMICS S120 Chassis Format Units and
Cabinet Modules D 21.3
can be obtained at
www.siemens.com/drives/infocenter
2
© Siemens AG 2014

Content Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SIMOTICS Distribution Motors
Key features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Special features . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Applicable standards and specifications. . . . . . . . . . 9

Motor selection . . . . . . . . . . . . . . . . . . . . . . . . 10
Motor selection and article number structure . . . . 10
Type of construction. . . . . . . . . . . . . . . . . . . . . . . . 17
SIMOTICS General Purpose – Aluminum series (400 V)
IE1 Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
IE2 Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
SIMOTICS General Purpose – Cast Iron series (400 V)
IE1 Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
IE2 Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
SIMOTICS General Purpose – Cast Iron series (525 V)
IE1 Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
IE2 Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Distribution Motor Options. . . . . . . . . . . . . . . . . . . 30
Special features detail . . . . . . . . . . . . . . . . . . 34
Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
IP rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Thermal class . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Derating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Anti-condensation . . . . . . . . . . . . . . . . . . . . . . 39
Motor protection . . . . . . . . . . . . . . . . . . . . . . . 40
Converter-fed application. . . . . . . . . . . . . . . . . 41
Noise. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Bearing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Terminal box. . . . . . . . . . . . . . . . . . . . . . . . . . . 54

1LE0 option line . . . . . . . . . . . . . . . . . . . . . . . 56


1LE0 option line . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Product highlights. . . . . . . . . . . . . . . . . . . . . . . . . . 57
Article number explanation . . . . . . . . . . . . . . . . . . 59
List of options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

Dimensional drawings . . . . . . . . . . . . . . . . . . 62
Aluminum series – 1LA7 . . . . . . . . . . . . . . . . . . . . 64
Aluminum series – 1LE10. . . . . . . . . . . . . . . . . . . . 64
Cast Iron series – 1LE0 . . . . . . . . . . . . . . . . . . . . . . 66
Flange dimensions
Aluminum series – 1LA7 . . . . . . . . . . . . . . . . . . 68
Aluminum series – 1LE10. . . . . . . . . . . . . . . . . . 69
Cast Iron series – 1LE0 . . . . . . . . . . . . . . . . . . . . 69

User parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Handling and storage . . . . . . . . . . . . . . . . . . . . . . . 76
Certificates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

3
© Siemens AG 2014

Introduction
General overview
Our low-voltage motors meet the latest efficiency stan-
SIMOTICS – dards and stand for highest quality, reliability and com-
The name for the widest range pactness. Our motors are optimally integrated into the
of motors in the world drive train. They are perfectly harmonized for the use with
SIRIUS motor starters and SINAMICS frequency converters.
With 150 years of experience, we have driven motor
technology forward, optimized them and played a Our foundation of outstanding quality is the unparalleled
decisive role in defining them. experience from numerous Siemens production facilities
around the world and close to our customers. This is how
Based on over 150 years of experience Siemens offers our experience drives your success!
with SIMOTICS the most comprehensive range of
motors for industrial applications proven with more Siemens is present in more than 190 countries around
than 40 million Siemens motors and drives installed the world and a true local global player. We manufacture
around the world. locally serving the individual markets. All of our products
are based on one common global quality and design stan-
dard derived from our German engineering roots adapted
to global market requirements.
We are present in your local market, understand your
market’s needs and also comply with local requirements
and standards.

Let us show you how our experience and our partnership


will drive your success with a new motors series specifi-
cally defined for the distribution business.

SIMOTICS low-voltage motors Cut-away aluminum motor

4 Chapter 1 · Introduction
© Siemens AG 2014

This brochure is using all of our 150 years experience


and focuses on our SIMOTICS low-voltage IEC motors,
especially defined for the distribution market. It covers
both Aluminum and Cast Iron series motors for general
purpose. Additional offering is always available from our
standard motor catalog portfolio. We comply with the
latest efficiency standards and describe motors for both
the IE1 and IE2 efficiencies. IE1 Aluminum Motor (1LE10 & 1LA7)
• Frame size: 63 – 160
Although Siemens also has ranges for IE3 and specific • Rated output: 0.12 – 18.5 kW
solutions for IE4 efficiency, these are still considered • No. of poles: 2, 4 and 6
specialized and are not described in this document. • Voltage & frequency: 400 V ± 5%, 50 Hz and other
In addition to these general IE1 and IE2 solutions, Siemens voltages and frequencies
can also provide specific variants for specific markets i.e. • Type of construction: IM B3 and other types of
in India, Korea, China etc. In such instances please consult construction
your local Siemens representative.
IE2 Aluminum Motor (1LE10)
• Frame size: 80 – 160
Our motor offering for the distribution market already
• Rated output: 0.55 – 18.5 kW
includes the most common features required in your local
• No. of poles: 2, 4 and 6
market and country, e.g. drain holes, embedded PTCs and
• Voltage & frequency: 400 V ± 5%, 50 Hz and other
more.
voltages and frequencies
• Type of construction: IM B3 and other types of
construction

IE1 Cast Iron Motor (1LE0)


• Frame size: 80 – 355
• Rated output: 0.55 – 315 kW
• No. of poles: 2, 4 and 6
• Voltage & frequency: 400 V ± 5%, 50 Hz and other
voltages and frequencies
• Type of construction: IM B3 and other types of
construction
IE2 Cast Iron Motor (1LE0)
• Frame size: 80 – 355
• Rated output: 0.55 – 315 kW
• No. of poles: 2, 4 and 6
• Voltage & frequency: 400 V ± 5%, 50 Hz and other
voltages and frequencies
• Type of construction: IM B3 and other types of
construction

SIMOTICS 1LE0 Cast Iron motor

Chapter 1 · Introduction 5
© Siemens AG 2014

SIMOTICS Distribution Motors – Key features


In order to maximize inventory turn rates, minimize The low-voltage motor unique key features:
complexity, decrease stock levels and minimize your invest-
ment required, we defined a specific distribution portfo- 1. Low vibration
lio already including most common required features as The low vibration results from our precison manufacturing
standard. In addition we offer an additional selection of and the use of defined and controlled quality compo-
options with which you can modify the distribution offer- nents. The quality bearings used augment this and result
ing even more. in longer life and lower noise. See chapter 1 – Applicable
standards and specifications for details.
Besides we can always offer you the most comprehensive
motor portfolio made to order for all applications and 2. Drain hole as standard (1LE0)
industries available from our standard catalog portfolio Drain holes as standard make sure condensed water does
D 81.1 and SIMOTICS GP 1LE0 Low-voltage Motors catalog not stay inside of the motor. This is especially important in
offering D 81.5N 09-2011. humid environment and big temperature deltas.

3. Bearing for high cantilever forces and longer lifetime


Bearings in our motors are not only designed for high canti-
lever forces, but also to make sure the motors run smooth.

4. True IP55 as standard


Our IP55 design covers a vast majority of applications and
is tested and proven for full lifetime, plus you have the full
modification possibility within IP55 rating.

5. F to B thermal class for built-in reserve


The Siemens motors are rated at normal sinusoidal volt-
age with a class B (130 °C) temperature rise. The windings
are rated to class F (155 °C) thus allowing for reserve for
the additional losses associated with variable speed drive
operation and / or higher ambient temperature and / or
overload conditions when operating directly on-line.
F to F is possible for converter-fed operation.

6. Converter-fed operation for variable speed as standard


For all motors offered up to 460 V converter-fed operation
is possible as standard configuration – no special option or
series is needed.

7. Embedded thermal protection 3x PTC


(1LE0/1LA7 and 1LE1 motors)
Thermal protection with PTC thermistors with 3 embedded
temperature sensors for tripping is provided in our IE2
motors above frame size 112 as standard version.

8. Global motor platform


Our motor design is based on one global motor platform
with the same look and feel on all low-voltage motor
IEC products.

9. Prepared for easy modification and mount auxiliaries


Our distribution motors are equipped with metal fan cover
and center hole on non-drive end shaft for easy modifica-
tion and mount auxiliaries.

For details on the above mentioned key features,


please see chapter 3 “Special features detail”.

6 Chapter 1 · Introduction
© Siemens AG 2014

SIMOTICS Distribution Motors – Special features


SIMOTICS General Purpose
Aluminum Series Cast Iron Series
Efficiency class IE1 IE2 IE1 IE2
Series 1LA7 1LE1002 1LE1001 1LE0102 1LE0101
1 Low vibration     
2 Drain hole as the standard     
3 Bearing for high cantilever forces and longer lifetime     
4 IP55 as the standard     
5 F to B thermal class     
6 Converter-fed operation for variable torque     
7 Embedded thermal protection 3xPTC     
8 Global motor platform     
9 Prepared for easy modification and auxiliary mounting –   – 

 = Standard
 = Option in distribution portfolio
– = Not available

63 71 80 90 100 112 132 160 180 200 225 250 280 315 355 Series
Aluminum Standard Efficiency IE1 1LA7 0.09 … 2.2 kW 1
1LE1002 1.5 ... 18.5 kW 2
High Efficiency IE2 1LE1001 0.37 … 18.5 kW 3
Cast Iron Standard Efficiency IE1 1LE0102 0.55 … 315 kW 4
High Efficiency IE2 1LE0101 0.55 … 315 kW 5

Did you know ?


An oversized motor is seldom recommended,
it normally has disadvantages including:
• Higher cost in investment and operation
• A higher current resulting from a poorer
power factor
• A bigger frame size and extended dimensions.

Chapter 1 · Introduction 7
© Siemens AG 2014

SIMOTICS Distribution Motors – Special features


SIMOTICS General Purpose
Aluminum Series Cast Iron Series
Efficiency class IE1 IE2 IE1 IE2
Series 1LA7 1LE1002 1LE1001 1LE0102 1LE0101
Voltage Standard 400 V ± 5% 400 V ± 5% 400 V ± 5% 400 V ± 5% 400 V ± 5%
and Optional voltage @ 50 Hz 380 V, 415 V, 525 V 380 V, 415 V, 525 V 380 V, 415 V, 525 V 380 V, 415 V, 525 V 380 V, 415 V, 525 V
frequency Converter-fed operation (a)     
Type of Standard IM B3 IM B3 IM B3 IM B3 IM B3
construction Optional IM B35, IM B5, IM B35, IM B5, IM B35, IM B5, IM B35, IM B5, IM B35, IM B5,
IM V1, IM B14 IM V1, IM B14 IM V1, IM B14 IM V1, IM B14 IM V1, IM B14
Bearing Bearing 62 C     (b)  (b)
designation Bearing 63 C – ‘ ‘  (b)  (b)
Others Metal fan cover     
Metal rating plate  – –  
Drain hole ‘ ‘ ‘  (b)  (b)
Center hole at non-drive
end prepared for auxiliary –  (b)  –  (b)
mountings
Space heater     
Motor
3 x PTC      (b)
protection
Certificate Extra rating plate
    
for voltage tolerance
CE marking – –  – 
Routine test     
Standard Stone grey (RAL 7030)     
color
 = Standard
 = Option in distribution portfolio
‘ = Not available in distribution portfolio, only from standard catalog
– = Not available
(a) = The limit for converter-fed operation is 460 Vrms +10%.
(b) = Depending on frame size and/or number of poles, please see respective sections.

TIP TIP
All motors up to 460 V can be operated On our SIMOTICS GP 1LE0 motors we have an
either directly on line or converter-fed – additional sticker mentioning voltage deviation
without the need for any additional measures. as standard. On our other product line, deviations
Both is possible as standard. should be mentioned, please add option code B07.

TIP
All our motors are shown as 400 V as the nominal standard.
The IEC 60034 regulations state that the nameplate data is only
valid at the specific given voltage. In practice, all listed 400 V
motors may be used at connection voltages 400 V ± 5%.
The motors will function well, although there would be
deviaions from the nominal electrical nameplate data.
All 1LE0 motors will have a sticker in addition on the cowl as
standard giving the nominal connection voltage as 400 V ± 5%.
According to the standard, motors can also be operated
at 400 V ± 10% (Category B), only longer operation is not
recommended.

8 Chapter 1 · Introduction
© Siemens AG 2014

Applicable standards and specifications

Title IEC
Efficiency classes and efficiencies IEC 60034-30:2008
Rotating electrical machines – Part 1: Rating and performance IEC 60034-1
Rotating electrical machines – Part 2-1: IEC 60034-2
Standard methods for determining losses and efficiency from tests (excluding machines for traction vehicles)
Rotating electrical machines – Part 5: IEC 60034-5
Degrees of protection provided by the integral design of rotating electrical machines (IP code) – Classification
Rotating electrical machines – Part 6: Methods of cooling (IC Code) IEC 60034-6
Rotating electrical machines – Part 7: IEC 60034-7
Classification of types of construction, mounting arrangements and terminal box position (IM Code)
Rotating electrical machines – Part 8: Terminal markings and direction of rotation IEC 60034-8
Rotating electrical machines – Part 9: Noise limits IEC 60034-9
Rotating electrical machines – Part 14: Mechanical vibration of certain machines with shaft heights 56 mm and higher – IEC 60034-14
Measurement, evaluation and limits of vibration severity
Rotating electrical machines – Part 1: Frame numbers 56 to 400 and flange numbers 55 to 1080 IEC 60072-1
Electrical insulation – Thermal classification IEC 60085
Classification of environmental conditions Part 2-1: IEC 60721-2-1
Environmental conditions appearing in nature – Temperature and humidity
Standard voltages IEC 60038

IEC 60034-1 differentiates between Category A The motors can supply their rated torque in both
(combination of voltage deviation ±5 % and frequency Category A and B. In Category A, the temperature rise is
deviation ±2 %) and Category B (combination of voltage approximately 10 K higher than during normal operation.
deviation ±10 % and frequency deviation +3 % / -5 %)
for voltage and frequency fluctuations.

Standard 60034-1 Category A Category B


Tolerance for electrical data
Voltage deviation ±5 % ±10 %
 Efficiency  at
Frequency deviation ±2 % 3 % / -5 %
Prated ≤ 150 kW: - 0.15 x (1 – )
Rating plate data stamped a ±5 % a ±10 % Prated > 150 kW: - 0.10 x (1 – )
with rated voltage a (e.g. 230 V ±5 %) (e.g. 230 V ±10 %) With  being a decimal number
(e.g. 230 V)
 Power factor - (1 – cos ) / 6
Rating plate data stamped b -5 % to c +5 % b -10 % to c +10 %
Minimum absolute value: 0.02
with rated voltage ranges (e.g. 220 V -5 % (e.g. 220 V -10 %
b to c (e.g. 220 V to 240 V) to 240 V +5 %) to 240 V +10 %) Maximum absolute value: 0.07
 Slip ±20 % (for motors < 1 kW ±30 % is admissible)
Rotors are dynamically balanced with half key.
 Locked-rotor current +20 %
This corresponds to vibration quantity level A.
 Locked-rotor torque -15 % to +25 %
 Breakdown torque -10 %
 Moment of inertia ±10 %

Limits (rms values) for max. vibration quantity of vibration distance (s), vibration speed (v) and acceleration (a) for the shaft height H
Vibration Machine Shaft height H in mm
quantity installation 56 ≤ H ≤ 132 132 < H ≤ 280 H > 280
level srms vrms arms srms vrms arms srms vrms arms
µm mm/s mm/s2 µm mm/s mm/s2 µm mm/s mm/s2
A Free suspension 25 1.6 2.5 35 2.2 3.5 45 2.8 4.4
Rigid clamping 21 1.3 2.0 29 1.8 2.8 37 2.3 3.6
B Free suspension 11 0.7 1.1 18 1.1 1.7 29 1.8 2.8
Rigid clamping – – – 14 0.9 1.4 24 1.5 2.4

Chapter 1 · Introduction 9
© Siemens AG 2014

Motor selection
Motor selection and article number structure
Here is our comprehensive distribution motor portfolio,
offering both Aluminum and Cast Iron series IE1 and IE2
efficiency. Our portfolio is covering power ratings from
0.09 kW up to 315 kW and frame sizes 63 to 355.

SIMOTICS General Purpose


Aluminum Series
Efficiency class IE1 IE2
Series 1LA7 1LE1002 1LE1001
No. of poles 2 4 6 2 4 6 2 4 6
Cooling Self-ventilated (IC 411) Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B) Thermal class 130(B)
Frame size 63 ... 90 100 ... 160 80 ... 160
Rated output at 50 Hz 0.09 ... 2.2 kW 1.5 ... 18.5 kW 0.37 ... 18.5 kW
Rated torque at 50 Hz 0.61 ... 11 Nm 10 ... 109 Nm 2.6 ... 108 Nm
Rated power (kW)
0.09 – –  – – – – – –
0.12 –  – – – – – – –
0.18    – – – – – –
0.25    – – – – – –
0.37    – – – – – 
0.55    – – – –  
0.75    – – –   
1.1    – – –   
1.5   – – –    
2.2  – – –     
3 – – –      
4 – – –      
5.5 – – –      
7.5 – – –      
11 – – –      
15 – – –   –   –
18.5 – – –  – –  – –

 = Available
– = Not available

Did you know ? General note:


Aluminum is a better conductor of heat than All data shown in this brochure is reflecting 50 Hz data if
Cast Iron. For this reason Aluminum motors can not otherwise specified.
feel warmer – keeping the inside cooler.
Cast Iron may feel colder on the outside but the
motor is sweating more on the inside.

10 Chapter 2 · Motor selection


© Siemens AG 2014

Did you know ?


All our described motors have a repeated starting
capability.
Those motors used on a frequency converter ramping
quickly from 0 Hz do not overheat and have an unlimited
starting capability. (also see section “converter-fed
application”)
Those motors started direct on-line heat slightly each time
they start. The number of starts can only be calculated if
many parameters are known.
As a rule, three successive normal starts for a cold motor
and two successive starts for a warm motor are accepted.

SIMOTICS General Purpose


Cast Iron Series
Efficiency class IE1 IE2
Series 1LE0102 1LE0101
No. of poles 2 4 6 2 4 6
Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm
Rated power (kW)
0.55 –   –  
0.75      
1.1      
1.5      
2.2      
3      
4      
5.5      
7.5      
11      
15      
18.5      
22      
30      
37      
45      
55      
75      
90      
110      
132      
160      
185      
200      
220      
250      
280   –   –
315   –   –

 = Available
– = Not available

Chapter 2 · Motor selection 11


© Siemens AG 2014

Motor selection and article number structure


Besides the already embedded distribution features we Aluminum Series Frame size availability
offer an additional selection of options with which you can SIMOTICS GP 1LA7 Standard Efficiency IE1 1
customize the distribution offering even more. SIMOTICS GP 1LE10 Standard Efficiency IE1 2
The option range covers mainly different voltages and
SIMOTICS GP 1LE10 High Efficiency IE2 3
mounting types, mechanical design and many other
commonly required features. Cast Iron
SIMOTICS GP 1LE0102 Standard Efficiency IE1 4
Note: SIMOTICS GP 1LE0101 High Efficiency IE2 5
Please refer to chapter 2 for distribution motor option
selection. 63 71

Voltage and frequency


400 V, 50 Hz  
380 V, 50 Hz  
415 V, 50 Hz  
525 V, 50 Hz  
Type of construction
IM B3  
IM B35  
IM B5  
IM V1 (a)  
IM B14  
Mechanical design and degrees of protection
Condensation drain holes ‘ ‘
Drive-end seal for flange-mounting motors,
oil-tight to 0.1 bar
 

Heating and ventilation


Anti-condensation heating for 230 V  
Anti-condensation heating for 115 V  
Motor protection
Motor protection with PTC thermistors with 1
(for motors 1LE10 FS 80 and 90) or  
3 embedded temperature sensors for tripping
Bearing and lubrication

Did you know ?


Bearing design
– –
for increased cantilever forces
Regreasing device – –

Motors can be offered with anti-condensation Packing, safety notes, documentation and certificate
heating as an option. Extra rating plate
 
Retrofitting of small motors is not so easy. for voltage tolerance
An alternative is to switch one delta-winding or two Acceptance test certificate 3.1
 
star-winding connections across a lower voltage in accordance with EN 10204 (routine test)
supply. The motor cannot turn and is heated. The CE marking – –
voltage should be selected at ~10% of the nominal. Sea-worthy packing for export  

 = Standard
 = Option in distribution portfolio
‘ = Not available in distribution portfolio, only from standard catalog
– = Not available
(a) = For canopy as modification, please see chapter 5
(b) = Depends on frame size or number of poles,
please see respective sections
(c) = Only for IE2 motors

12 Chapter 2 · Motor selection


© Siemens AG 2014

80 90 100 112 132 160 180 200 225 250 280 315 355

            
            
            
            

            
            
            –
            
      – – – – – – –

‘ 2, 3 ‘ 2, 3 ‘ 2, 3
‘ ‘ ‘       
 4, 5  4, 5  4, 5
     
– – – – – – –
– 4, 5 – 4, 5 – 4, 5 – 4, 5 – 4, 5 – 4, 5

            
            

 2, 3, 4  2, 3, 4  4  4  4  4  4  4  4
   
5 5 5 5 5 5 5 5 5

 2, 3, 4  2, 3, 4  2, 3, 4
– –        
 5 (b)  5 (b)  5 (b)
– –           

     
      
 4, 5  4, 5  4, 5  4, 5  4, 5  4, 5

            

 (c)  (c)  (c)  (c)  (c)  (c)  (c)  (c)  (c)  (c)  (c)  (c)  (c)
            

Chapter 2 · Motor selection 13


© Siemens AG 2014

Motor selection and article number structure · 16 digits


Overview
The article number consists of a combination of figures defines the motor frame size and length, the number of
and letters and is divided into three blocks linked with poles and in some cases the frequency/output;
hyphens for a better overview. and in the third block (Position 13 to 16) the frequency/
The first block (Position 1 to 7) identifies the motor type output, type of construction and other design features are
and efficiency level; the second block (Position 8 to 12) encoded.

Structure of Article No. (1LE0 and 1LE10 series)


Structure Position: 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z
Position 1 to 6: Low-voltage motor series
• Cast Iron / Distribution line 1 L E 0 1 0
• Aluminum 1 L E 1 0 0
Position 7: Motor efficiency
• Motor with high efficiency - IE2 1
• Motor with improved efficiency - IE1 2
Position 8 and 9: Frame size
• 0D = 080; 0E = 090
• 1A = 100; 1B = 112; 1C = 132; 1D = 160; 1E = 180
• 2A = 200; 2B = 225; 2C = 250; 2D = 280
• 3A = 315; 3B = 355
Position 10: Number of poles
• A = 2; B = 4; C = 6
Position 11: Frame length
• 0 or 1 = S (short)
• 2 or 3 = M (medium)
• 4, 5, 6 or 7 = L (long) (a)
Position 12 and 13: Voltage, circuit and frequency
• 22 = 230 VD 50 Hz
• 34 = 400 VD 50 Hz
• 33 = 380 VD 50 Hz
• 35 = 415 VD 50 Hz
• 41 = 525 VD 50 Hz
• 90 (b) = special voltage & frequency
Position 14: Type of construction
• A = IM B3
• J = IM B35
• F = IM B5
• G = IM V1
• K = IM B14
Position 15: Motor protection
• A = without winding protection
• B = 3 PTC thermistors for tripping
Position 16: Terminal box location (view from drive end)
• 4 = terminal box on top
Special order version
Coded - Order (option) code also required (b)
(a) For 1LE0 FS315 and 355 motors, digit 4 still stands for Medium (M).
(b) For deviations in the second and third block from the catalog codes, either –Z or 90 should be used as appropriate,

e.g. 1LE0101-1DB23-4AB4-Z Z=B02; or 1LE0101-1DB29-0AB4-Z Z=L1R.

Ordering example
Selection criteria Requirement Structure of the Article No.
Motor type Cast Iron motor with IP55 degree of protection 1LE010--
Efficiency High efficiency IE2 1LE0101--
Motor frame size / No. of poles / Speed 160 / 4-pole / 1500 rpm
1LE0101-1DB2-
Rated output 11 kW
Voltage and frequency 400 V, 50 Hz 1LE0101-1DB23-4
Type of construction IM B3 1LE0101-1DB23-4A
Motor protection 3 PTC thermistors 1LE0101-1DB23-4AB
Mechanical design Terminal box on top 1LE0101-1DB23-4AB4
Special versions Anti-condensation heating for 230 V 1LE0101-1DB23-4AB4-Z Q02

14 Chapter 2 · Motor selection


© Siemens AG 2014

Motor selection and article number structure · 12 digits


Overview
The article number consists of a combination of figures The first block (Position 1 to 7) identifies motor type and
and letters and is divided into two blocks linked with motor frame size; and the second block defines number of
hyphens for a better overview. poles, frequency/output and type of construction.

Structure of Article No. (1LA7 series)


Structure Position: 1 2 3 4 5 6 7 - 8 9 10 11 12 - Z
Position 1 to 4: Low-voltage motor series
• IE1 Aluminum motor 1 L A 7
Position 5 to 7: Frame size
(frame size comprising shaft height and construction length)
• 060
• 063
• 070
• 073
• 080
• 083
• 090
• 096
Position 8: Number of poles
•2
•4
•6
Position 9 to 10: Version
• AA
• AB
Position 11: Voltage, circuit and frequency
• 6 = 400 VD 50 Hz
• 9 (a) = special voltage & frequency (b)
Position 12: Type of construction
• 0 = IM B3
• 6 = IM B35
• 1 = IM B5
• 1 = IM V1
• 2 = IM B14
Special order version
Coded - Order (option) code also required (a)
(a) For deviations in the second and third block from the catalog codes, either –Z or 9 should be used as appropriate,
e.g. 1LA7080-2AA60-Z Z=B02; or 1LA7080-2AA90 Z=L1C.
(b) L1L for 380 V, 50 Hz; L1C for 415 V, 50 Hz.

Ordering example
Selection criteria Requirement Structure of the Article No.
Motor type Aluminum motor IE1 efficiency 1LA7-
Motor frame size / No. of poles / Speed 4-pole / 1500 rpm
1LA7080-4AA
Rated output 0.55 kW
Voltage and frequency 400 V, 50 Hz 1LA7080-4AA6
Type of construction IM B3 1LA7080-4AA60
Special versions Anti-condensation heating for 230 V 1LA7080-4AA60-Z K45

Chapter 2 · Motor selection 15


© Siemens AG 2014

Motor selection and article number


Name plates

1LA7 series
Legend:
1 Three-phase low-voltage 13 Efficiency class
motor 14 Balance method and
7 9 10 15 1 23 2 3 17 16 14 20 2 Article No. efficiency class
3 Factory number 15 Machine weight [kg]
3~Mot. 1LA71662AA60-Z H
E 0107/471101 01 001 IEC/EN 60034 (Ident No., serial number) 16 Standards and regulations
Made in Czech Republic IM B3 160L IP55 Th.Cl.155(F) Tamb 40°C
93kg 4 Type of construction 17 Temperature class
50Hz 400/690V ∆/Y 60Hz 460V ∆
5 Degree of protection 18 Frame size
18,5kW 33,0/19,1A 21,3kW 33,0A

G_D081_EN_00375
cos φ 0,91 2940/min cos φ 0,92 3540/min 6 Rated voltage [V] and 19 Additional details (optional)
IE1-89,3% IE1-89,5% winding connections
20 Operating temperature
7 Frequency [Hz] range (only if it deviates
8 Rated current [A] from normal)
13 22 11 6 8 12 4 18 5 19 21 9 Rated output [kW] 21 Site altitude (only when
higher than 1000 m)
10 Power factor [cos ]
22 Customer data (optional)
11 Efficiency
23 Date of manufacture YYMM
12 Rated speed [rpm]

1LE10 series
Legend:
1 Three-phase low-voltage 13 Efficiency class
18 2 4 14 23 3 motor 14 Balance method and
H 2 Article No. efficiency class
Made in Germany
1 3~Mot. 1LE1001-1DA234AA4 E 1202/5331139_01001 3 Factory number 15 Machine weight [kg]
16 IEC/EN 60034 160M IM B3 IP 55 5 (Ident No., serial number) 16 Standards and regulations
15 67kg Th.CI. 155(F) -20°C <=TAMB<=40°C
Bearing
4 Type of construction 17 Temperature class
17 21
DE 6209-2ZC3
20 5 Degree of protection 18 Frame size
NE 6209-2ZC3
19 6 Rated voltage [V] and 19 Additional details (optional)
V Hz A kW COS NOM.EFF 1/min IE-CL winding connections
400 D 50 20.5 11.0 0.87 89.4% 2955 IE2 20 Operating temperature
690 Y 50 11.8 11.0 0.87 89.4% 2955 IE2 7 Frequency [Hz] range (only if it deviates
450 D 60 19.9 12.6 0.88 90.2% 3555 IE2 8 Rated current [A] from normal)
460 D 60 17.8 11.0 0.86 90.2% 3560 IE2
22 9 Rated output [kW] 21 Site altitude (only when
G_D081_EN_00374 higher than 1000 m)
6 7 8 9 10 11 12 13 10 Power factor [cos ]
11 Efficiency 22 Customer data (optional)
12 Rated speed [rpm] 23 Date of manufacture YYMM

1LE0 series
Legend:
1 Three-phase low-voltage 12 Rated speed
16 4 5 11 3 motor 13 Machine weight (kg)
G_D081_EN_00358

2 Article No. 14 Standards


Made in P.R.China SIEMENS STANDARD MOTORS LTD. H 21 3 Series number 15 Temperature class
2
1 3~MOT 1LE0102-2AB43-4AA4-Z 200L IMB3 IP55 LMH-0209 / 800003888993 / 004 4 Type of construction 16 Frame size
6 V Hz kW A EFF. cos φ r/min EFF.CI.
5 Degree of protection
400/690 ∆/Υ 50 30 56/32.5 90.7% 0.85 1470 IE1 20 17 Ambient temperature
7 60 33.5 48.5 91.7% 0.85 1765 12 6 Rated voltage
460 ∆ 18 Bearing at drive end
BRG DE 6312ZJ C3 BRG NDE 6312ZJ C3 Th.Cl.155(F) AMB 40 °C
7 Frequency (Hz) 19 Bearing at non-drive end
8 Rated output (kW) 20 Efficiency class
IEC60034 Net: 238 kg
9 Rated current (A) 21 Balance method
14 18 8 9 19 11 15 10 13 17
10 Power factor (cos )
1 Three-phase low-voltage motor 12 Rated speed
2 Order No. 13 Machine weight (kg) 11 Efficiency
3 Series number 14 Standards

16 Chapter 2 · Motor selection


© Siemens AG 2014

Type of construction
In addition to the basic IM B3 type of construction, motors The possible versions in our selection for a particular motor
can also be supplied in other types of construction. type can be taken from the table below.
We provide most commonly used type of constructions in
our selection for you, as well as possibility for own modifi-
cation.

Standard type of construction and special type of construction


Type of construction
according to DIN EN 60034-7
Frame
size
16 Digits Article No. 12 Digits Article No.
14th position 12th position
Did you know ?
of the Article No. of the Article No. When mounting the motors in
diverse orientations consider
the location of the drain hole –
IM B3 63 to 355 A 0 it must be at the lowest point to
drain water.

IM B35 63 to 355 J 6

IM B5 63 to 315 F 1

IM V1 63 to 355 G 1

IM B14 63 to 160 K 2

Apart from the distribution portfolio covered mounting


types, here is the general overview of the possible mount- TIP
ing types. Many of them can be achieved by modifying this
offered portfolio. Anything else can still be supplied out of Mounting motors in orientations
our standard catalog portfolio, see D 81.1 other than these intended could
lead to mechanical or structual
premature failure.
If in any doubt, please consult
your Siemens partner.
Types of construction

IM B3 IM B6 IM B7 IM B8 IM V5 IM V6 IM B14 IM V18 IM V19

IM B5 IM V1 IM V3 IM B9 IM V8 IM V9 IM B35 IM B34

Types of construction according to DIN IEC 34, Part 7

Chapter 2 · Motor selection 17


© Siemens AG 2014

SIMOTICS General Purpose (Aluminum Series) – IE1


TIP
Aluminum Series
The nominal torque Efficiency class IE1 IE2
of the motor is easy to calculate; Series 1LA7 1LE1002 1LE1001
No. of poles 2 4 6 2 4 6 2 4 6
Torque (Nm) =
Cooling Self-ventilated (IC 411) Self-ventilated (IC 411) Self-ventilated (IC 411)
Power (kW) x 9550 / Speed (rpm). Degree of protection IP55 IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B) Thermal class 130(B)
Frame size 63 ... 90 100 ... 160 80 ... 160
Rated output at 50 Hz 0.09 ... 2.2 kW 1.5 ... 18.5 kW 0.37 ... 18.5 kW
Rated torque at 50 Hz 0.61 ... 11 Nm 10 ... 109 Nm 2.6 ... 108 Nm

Electrical data - 1LA7 & 1LE10 - IE1 - 2-pole (IE1 Aluminum) 3000 rpm 2-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
0.18 63M 1LA7060-2AA.. - 2820 0.61 0.43 0.51 0.82 62.0 60.5 56.0 3.7 2.0 2.2 0.00018 16 3.6
0.25 63M 1LA7063-2AA.. - 2830 0.84 0.60 0.70 0.82 63.0 62.0 57.0 4.0 2.3 2.2 0.00022 16 4.0
0.37 71M 1LA7070-2AA.. - 2740 1.3 0.86 0.99 0.82 66.0 65.0 61.0 3.5 2.5 2.3 0.00029 16 5.0
0.55 71M 1LA7073-2AA.. - 2800 1.9 1.12 1.36 0.82 71.0 71.0 67.0 4.3 2.3 2.6 0.00041 16 6.0
0.75 80M 1LA7080-2AA.. IE 1 2855 2.5 1.34 1.75 0.86 72.1 72.1 68.1 5.6 2.6 2.4 0.00079 16 9.0
1.1 80M 1LA7083-2AA.. IE 1 2845 3.7 1.47 2.45 0.87 75.0 75.0 72.0 6.1 2.4 2.7 0.0010 16 10.7
1.5 90S 1LA7090-2AA.. IE 1 2860 5.0 2.10 3.3 0.85 77.2 77.7 74.2 5.5 2.8 2.7 0.0014 16 13.0
2.2 90L 1LA7096-2AA.. IE 1 2880 7.3 2.30 4.7 0.85 79.7 79.7 78.7 6.3 2.8 3.1 0.0018 16 15.7
3 100L 1LE1002-1AA4.-...4 IE 1 2835 10 2.77 6.1 0.87 81.5 82.8 82.1 6.2 3.2 2.9 0.0034 16 20
4 112M 1LE1002-1BA2.-...4 IE 1 2930 13 4.15 8.1 0.86 83.1 83.8 82.2 7.3 2.7 3.7 0.0067 16 25
5.5 132S 1LE1002-1CA0.-...4 IE 1 2905 18 4.37 10.5 0.89 84.7 85.7 85.0 5.6 1.9 2.5 0.013 16 35
7.5 132S 1LE1002-1CA1.-...4 IE 1 2925 24 6.1 14.5 0.87 86.0 86.9 85.8 6.3 2.1 3.2 0.016 16 40
11 160M 1LE1002-1DA2.-...4 IE 1 2925 36 9.13 21.5 0.85 87.6 87.6 86.1 5.8 2.0 2.6 0.030 16 60
15 160M 1LE1002-1DA3.-...4 IE 1 2930 49 12.4 29 0.84 88.7 89.0 88.0 6.1 2.5 3.1 0.036 16 68
18.5 160L 1LE1002-1DA4.-...4 IE 1 2935 60 13.38 35 0.86 89.3 90.0 89.7 7.0 2.5 3.2 0.044 16 78

Electrical data - 1LA7 & 1LE10 - IE1 - 4-pole (IE1 Aluminum) 1500 rpm 4-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
0.12 63M 1LA7060-4AB.. - 1350 0.85 0.40 0.43 0.75 53.6 52.1 47.6 2.8 1.9 2.0 0.00029 13 3.6
0.18 63M 1LA7063-4AB.. - 1350 1.3 0.52 0.58 0.77 58.3 56.8 52.3 3.0 1.9 1.9 0.00037 13 4.0
0.25 71M 1LA7070-4AB.. - 1350 1.8 0.72 0.75 0.78 61.9 60.4 55.9 3.0 1.9 1.9 0.00052 13 4.8
0.37 71M 1LA7073-4AB.. - 1370 2.6 0.93 1.04 0.78 65.8 64.8 60.8 3.3 1.9 2.1 0.00077 13 6.3
0.55 80M 1LA7080-4AA.. - 1395 3.8 1.30 1.41 0.81 69.4 69.4 65.4 3.9 2.2 2.2 0.0014 16 8.8
0.75 80M 1LA7083-4AA.. IE 1 1395 5.1 1.57 1.88 0.80 72.1 72.1 68.1 4.2 2.3 2.3 0.0017 16 10.0
1.1 90S 1LA7090-4AA.. IE 1 1415 7.4 2.00 2.6 0.81 75.0 75.0 72.0 4.6 2.3 2.4 0.0024 16 12.9
1.5 90L 1LA7096-4AA.. IE 1 1420 10 2.65 3.45 0.81 77.2 77.7 74.2 5.3 2.4 2.6 0.0033 16 15.5
2.2 100L 1LE1002-1AB4.-...4 IE 1 1425 15 2.36 4.9 0.81 79.7 80.5 78.5 5.1 2.2 2.3 0.0059 16 18
3 100L 1LE1002-1AB5.-...4 IE 1 1425 20 3.11 6.3 0.85 81.5 83.0 82.3 5.4 2.4 2.6 0.0078 16 22
4 112M 1LE1002-1BB2.-...4 IE 1 1435 27 4.04 8.2 0.85 83.1 84.5 84.0 5.3 2.2 2.6 0.01 16 27
5.5 132S 1LE1002-1CB0.-...4 IE 1 1450 36 6.04 11.2 0.82 84.7 85.7 84.9 5.7 2.3 2.7 0.019 16 38
7.5 132M 1LE1002-1CB2.-...4 IE 1 1450 49 7.94 15.2 0.82 86.0 86.9 86.3 6.6 2.6 3.1 0.024 16 44
11 160M 1LE1002-1DB2.-...4 IE 1 1460 72 12.40 22 0.82 87.6 88.0 86.6 6.4 2.3 3.1 0.044 16 62
15 160L 1LE1002-1DB4.-...4 IE 1 1460 98 15.90 30 0.82 88.7 89.3 88.3 7 2.5 3.4 0.056 16 73

Electrical data - 1LA7 & 1LE10 - IE1 - 6-pole (IE1 Aluminum) 1000 rpm 6-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
0.09 63M 1LA7063-6AB.. - 850 1.0 0.46 0.39 0.66 50.2 48.7 44.2 2.0 1.8 1.9 0.00037 13 4.0
0.18 71M 1LA7070-6AA.. - 850 2.0 0.65 0.67 0.68 57.3 55.8 51.3 2.3 2.1 1.9 0.00055 16 4.8
0.25 71M 1LA7073-6AA.. - 860 2.8 0.71 0.77 0.76 61.9 60.4 55.9 2.7 2.2 2.0 0.00080 16 5.8
0.37 80M 1LA7080-6AA.. - 920 3.8 1.18 1.16 0.72 64.1 63.1 59.1 3.1 1.9 2.1 0.0014 16 8.6
0.55 80M 1LA7083-6AA.. - 910 5.8 1.45 1.59 0.74 67.5 67.0 63.5 3.4 2.1 2.2 0.0017 16 9.8
0.75 90S 1LA7090-6AA.. IE 1 915 7.8 1.63 2.05 0.76 70.0 70.0 66.0 3.7 2.2 2.2 0.0024 16 12.6
1.1 90L 1LA7096-6AA.. IE 1 915 11.0 2.15 2.85 0.77 72.9 72.9 69.9 3.8 2.3 2.3 0.0033 16 15.7
1.5 100L 1LE1002-1AC4.-...4 IE 1 940 15 2.66 3.9 0.74 75.2 76.0 72.4 4 2 2.2 0.0065 16 19
2.2 112M 1LE1002-1BC2.-...4 IE 1 930 23 3.43 5.4 0.75 77.7 78.8 76.9 4.1 2.3 2.5 0.0092 16 25
3 132S 1LE1002-1CC0.-...4 IE 1 955 30 4.86 7.3 0.74 79.7 80.2 77.7 4.6 2 2.6 0.017 16 34
4 132M 1LE1002-1CC2.-...4 IE 1 950 40 5.47 9.3 0.76 81.4 82.9 82.1 4.7 2.1 2.5 0.021 16 39
5.5 132M 1LE1002-1CC3.-...4 IE 1 950 55 7.59 12.7 0.75 83.1 84.6 84.0 5.2 2.5 2.8 0.027 16 48
7.5 160M 1LE1002-1DC2.-...4 IE 1 970 74 10.73 17.5 0.73 84.7 85.4 85.0 5.5 2.1 2.9 0.056 16 72
11 160L 1LE1002-1DC4.-...4 IE 1 965 109 13.10 24 0.77 86.4 86.4 85.4 5.9 1.9 2.7 0.078 16 92

18 Chapter 2 · Motor selection


© Siemens AG 2014

SIMOTICS General Purpose (Aluminum Series) – IE2


Aluminum Series
Efficiency class IE1 IE2
Series 1LA7 1LE1002 1LE1001
No. of poles 2 4 6 2 4 6 2 4 6
Cooling Self-ventilated (IC 411) Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B) Thermal class 130(B)
Frame size 63 ... 90 100 ... 160 80 ... 160
Rated output at 50 Hz 0.09 ... 2.2 kW 1.5 ... 18.5 kW 0.37 ... 18.5 kW
Rated torque at 50 Hz 0.61 ... 11 Nm 10 ... 109 Nm 2.6 ... 108 Nm

Electrical data - 1LE10 - IE2 - 2-pole (IE2 Aluminum) 3000 rpm 2-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
0.75 80M 1LE1001-0DA2.-...4 IE 2 2805 2.6 0.89 1.67 0.84 77.4 79.5 78.8 4.9 1.9 2.3 0.0008 16 9
1.1 80M 1LE1001-0DA3.-...4 IE 2 2835 3.7 1.22 2.4 0.83 79.6 81.3 80.8 6 2.7 3.1 0.0011 16 11
1.5 90S 1LE1001-0EA0.-...4 IE 2 2885 5 1.91 3.15 0.84 81.3 82.3 80.8 6.9 2.7 3.6 0.0017 16 13
2.2 90L 1LE1001-0EA4.-...4 IE 2 2890 7.3 2.45 4.5 0.85 83.2 83.9 82.3 7.1 2.5 3.7 0.0021 16 15
3 100L 1LE1001-1AA4.-...4 IE 2 2905 9.9 3.3 6.1 0.84 84.6 85.2 84.7 7 2.3 3.3 0.0044 16 21
4 112M 1LE1001-1BA2.-...4 IE 2 2950 13 3.7 7.8 0.86 85.8 86.7 86.1 7.4 2.4 3.3 0.0092 16 27
5.5 132S 1LE1001-1CA0.-...4 IE 2 2950 18 4.3 10.5 0.87 87.0 88.0 87.4 6.6 1.8 2.9 0.02 16 39
7.5 132S 1LE1001-1CA1.-...4 IE 2 2950 24 5.7 14.1 0.87 88.1 88.7 88.6 7.5 2.2 3.1 0.024 16 43
11 160M 1LE1001-1DA2.-...4 IE 2 2955 36 8.4 20.5 0.87 89.4 90.0 89.1 7.4 2.1 3.2 0.045 16 67
15 160M 1LE1001-1DA3.-...4 IE 2 2955 48 10.6 27 0.88 90.3 90.9 90.3 7.6 2.4 3.4 0.053 16 75
18.5 160L 1LE1001-1DA4.-...4 IE 2 2955 60 13 33.5 0.88 90.9 91.2 90.4 7.9 2.9 3.6 0.061 16 84

Electrical data - 1LE10 - IE2 - 4-pole (IE2 Aluminum) 1500 rpm 4-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
0.55 80M 1LE1001-0DB2.-...4 - 1440 3.7 0.99 1.37 0.74 78.1 78.9 76.1 5.3 2.2 3.1 0.0017 16 10
0.75 80M 1LE1001-0DB3.-...4 IE 2 1440 5 1.21 1.79 0.76 79.6 80.2 78.0 5.6 2.2 3.1 0.0021 16 11
1.1 90S 1LE1001-0EB0.-...4 IE 2 1425 7.4 1.7 2.5 0.78 81.4 81.7 79.9 5.6 2.3 2.9 0.0028 16 13
1.5 90L 1LE1001-0EB4.-...4 IE 2 1435 10 21 3.3 0.79 82.8 83.5 82.0 6.4 2.6 3.4 0.0036 16 16
2.2 100L 1LE1001-1AB4.-...4 IE 2 1455 14 2.6 4.65 0.81 84.3 85.1 84.3 6.9 2.1 3.3 0.0086 16 21
3 100L 1LE1001-1AB5.-...4 IE 2 1455 20 3.35 6.2 0.82 85.5 86.7 86.0 6.9 2 3.1 0.011 16 25
4 112M 1LE1001-1BB2.-...4 IE 2 1460 26 4.3 8.2 0.81 86.6 87.3 86.5 7.1 2.5 3.2 0.014 16 29
5.5 132S 1LE1001-1CB0.-...4 IE 2 1465 36 5.7 11.3 0.8 87.7 89.0 87.7 6.9 2.3 2.9 0.027 16 42
7.5 132M 1LE1001-1CB2.-...4 IE 2 1465 49 6.5 14.7 0.83 88.7 90.3 88.8 6.9 2.3 2.9 0.034 16 49
11 160M 1LE1001-1DB2.-...4 IE 2 1470 71 8.7 21 0.85 89.8 90.9 90.8 6.7 2.1 2.8 0.065 16 71
15 160L 1LE1001-1DB4.-...4 IE 2 1475 97 11.3 28 0.85 90.6 91.3 91.0 7.3 2.3 3 0.083 16 83

Electrical data - 1LE10 - IE2 - 6-pole (IE2 Aluminum) 1000 rpm 6-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
0.37 80M 1LE1001-0DC2.-...4 - 925 3.85 0.81 1.08 0.69 71.4 71.5 66.5 4 2.1 2.4 0.001716 16 9
0.55 80M 1LE1001-0DC3.-...4 - 935 5.6 1.07 1.63 0.66 74.0 74.0 70.5 4.4 2.5 2.9 0.0025 16 12
0.75 90S 1LE1001-0EC0.-...4 IE2 925 7.7 1.2 2.05 0.7 75.9 76.0 73.0 4.1 2 2.5 0.003 16 13
1.1 90L 1LE1001-0EC4.-...4 IE2 935 11.2 1.93 2.9 0.7 78.1 78.5 75.0 4.4 2.2 2.6 0.004 16 16
1.5 100L 1LE1001-1AC4.-...4 IE2 970 15 2.2 3.7 0.73 79.8 80.2 79.0 6.2 2 2.9 0.011 16 25
2.2 112M 1LE1001-1BC2.-...4 IE2 965 22 2.9 5.2 0.75 81.8 82.5 81.3 6 2.1 3.1 0.014 16 29
3 132S 1LE1001-1CC0.-...4 IE2 970 30 4.2 7 0.74 83.3 84.0 82.8 5.6 1.6 2.6 0.024 13 38
4 132M 1LE1001-1CC2.-...4 IE2 970 39 4.5 8.7 0.78 84.6 85.8 85.0 5.6 1.6 2.5 0.029 13 43
5.5 132M 1LE1001-1CC3.-...4 IE2 970 54 6.3 12 0.77 86.0 87.4 87.0 6.1 1.9 2.8 0.037 16 52
7.5 160M 1LE1001-1DC2.-...4 IE2 975 73 8.25 16.1 0.77 87.2 87.7 86.9 6.3 1.8 2.8 0.075 16 77
11 160L 1LE1001-1DC4.-...4 IE2 975 108 10.1 22.5 0.8 88.7 89.5 89.4 6.2 1.7 2.7 0.098 16 93

Chapter 2 · Motor selection 19


© Siemens AG 2014

SIMOTICS General Purpose (Cast Iron) – IE1


TIP
Cast Iron Series
The nominal torque Efficiency class IE1 IE2
of the motor is easy to calculate; Series 1LE0102 1LE0101
Torque (Nm) = No. of poles 2 4 6 2 4 6
Power (kW) x 9550 / Speed (rpm). Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm

Electrical data - 1LE0 - IE1 - 2-pole (IE1 Cast Iron) 3000 rpm 2-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
230 V / 400 VY
0.75 80M 1LE0102-0DA22-2..4 IE 1 2800 2.6 0.95 1.76 0.86 72.1 73.0 71.1 5.1 2.3 2.7 0.0008 D 15.0
1.1 80M 1LE0102-0DA32-2..4 IE 1 2830 3.7 1.16 2.50 0.86 75.0 77.3 74.4 6 2.6 3.1 0.001 E 17.5
1.5 90S 1LE0102-0EA02-2..4 IE 1 2885 5 1.82 3.30 0.85 77.2 76.9 73.5 6.9 2.5 3.2 0.0017 F 22
2.2 90L 1LE0102-0EA42-2..4 IE 1 2885 7.3 2.15 4.50 0.87 79.7 80.5 78.1 7.5 2.7 3.4 0.0022 F 26
3 100L 1LE0102-1AA42-2..4 IE 1 2850 10 2.80 6.3 0.85 81.5 82.1 79.9 6.9 3 3.7 0.0033 F 33
4 112M 1LE0102-1BA22-2..4 IE 1 2910 13.1 6.5 8.2 0.85 83.1 83.7 81.5 7.8 2.9 4.2 0.0064 L 39
5.5 132S 1LE0102-1CA02-2..4 IE 1 2915 18 8.0 10.9 0.86 84.7 85.3 83.7 6.9 2 3.1 0.013 K 55
7.5 132S 1LE0102-1CA12-2..4 IE 1 2920 24.5 11.3 14.3 0.88 86.0 87.2 86.2 7.1 2 2.9 0.015 K 60
400 V / 690 VY
3 100L 1LE0102-1AA43-4..4 IE 1 2850 10 2.75 6.3 0.85 81.5 82.1 79.9 6.9 3 3.7 0.0033 F 33
4 112M 1LE0102-1BA23-4..4 IE 1 2910 13.1 3.80 8.2 0.85 83.1 83.7 81.5 7.8 2.9 4.2 0.0064 L 39
5.5 132S 1LE0102-1CA03-4..4 IE 1 2915 18 5.0 10.9 0.86 84.7 85.3 83.7 6.9 2 3.1 0.013 K 55
7.5 132S 1LE0102-1CA13-4..4 IE 1 2920 24.5 5.9 14.3 0.88 86.0 87.2 86.2 7.1 2 2.9 0.015 K 60
11 160M 1LE0102-1DA23-4..4 IE 1 2925 35.9 9.3 21.5 0.84 87.6 88.2 87.1 6.3 2 3.1 0.028 J 93
15 160M 1LE0102-1DA33-4..4 IE 1 2930 48.9 12.1 28.5 0.85 88.7 89.3 87.4 7 2.2 3.2 0.034 K 101
18.5 160L 1LE0102-1DA43-4..4 IE 1 2935 60 14.1 35.0 0.86 89.3 89.9 89.1 7.6 2.5 3.4 0.041 K 120
22 180M 1LE0102-1EA23-4..4 IE 1 2925 72 13.3 40.5 0.87 89.9 90.6 90.0 7.6 2.7 3.5 0.072 K 151
30 200L 1LE0102-2AA43-4..4 IE 1 2950 97 18.7 55 0.87 90.7 90.8 89.0 7.5 2.5 3.2 0.12 K 224
37 200L 1LE0102-2AA53-4..4 IE 1 2950 120 19.5 67 0.88 91.2 91.6 90.4 7.4 2.6 3.2 0.15 K 242
45 225M 1LE0102-2BA23-4..4 IE 1 2960 145 24.0 81 0.88 91.7 91.9 90.5 7.6 2.8 3.3 0.23 K 304
55 250M 1LE0102-2CA23-4..4 IE 1 2970 177 32.0 98 0.88 92.1 92.4 90.7 7.7 2.5 3.1 0.4 K 374
75 280S 1LE0102-2DA03-4..4 IE 1 2970 241 42.5 134 0.87 92.7 92.6 91.1 6.7 2.7 3 0.7 J 540
90 280M 1LE0102-2DA23-4..4 IE 1 2975 289 47.5 159 0.88 93.0 93.2 91.3 7.2 2.8 3 0.82 J 560
110 315S 1LE0102-3AA03-4..4 IE 1 2982 353 49.5 189 0.90 93.3 93.1 91.2 7.5 2.2 3.1 1.4 K 735
132 315M 1LE0102-3AA23-4..4 IE 1 2980 423 46.0 220 0.92 93.5 93.1 91.7 7.5 2.3 2.9 1.7 J 850
160 315L 1LE0102-3AA53-4..4 IE 1 2982 513 56 265 0.92 93.8 93.6 92.5 7.6 2.5 2.8 1.9 J 960
185 315L 1LE0102-3AA63-4..4 IE 1 2978 594 50 310 0.92 93.9 93.9 93.1 7.5 2.4 2.8 2.3 J 1070
200 315L 1LE0102-3AA73-4..4 IE 1 2980 641 65 335 0.92 94.0 94.3 93.2 7.9 2.5 2.6 2.3 K 1080
220 355M 1LE0102-3BA23-4..4 IE 1 2985 704 43.0 370 0.90 94.8 95.0 92.8 6.5 2 2.1 2.9 H 1590
250 355M 1LE0102-3BA33-4..4 IE 1 2985 800 54 420 0.90 95.2 95.2 93.0 6.5 2 2.1 3 H 1620
280 355L 1LE0102-3BA53-4..4 IE 1 2985 896 57 470 0.90 95.2 95.2 92.9 6.5 2 2.1 3.5 H 1820
315 355L 1LE0102-3BA63-4..4 IE 1 2985 1008 61 530 0.90 95.4 95.4 93.2 6.5 2 2.1 3.5 H 1830

20 Chapter 2 · Motor selection


© Siemens AG 2014

SIMOTICS General Purpose (Cast Iron) – IE1


Cast Iron Series
Efficiency class IE1 IE2
Series 1LE0102 1LE0101
No. of poles 2 4 6 2 4 6
Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm

Electrical data - 1LE0 - IE1 - 4-pole (IE1 Cast Iron) 1500 rpm 4-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
230 V / 400 VY
0.55 80M 1LE0102-0DB22-2..4 - 1415 3.7 0.76 1.43 0.81 69.4 69.9 66.8 4.5 2 2.6 0.0016 D 17.0
0.75 80M 1LE0102-0DB32-2..4 IE 1 1405 5.1 0.99 1.87 0.81 72.1 73.7 71.8 4.8 2 2.6 0.0019 D 18.5
1.1 90S 1LE0102-0EB02-2..4 IE 1 1420 7.4 1.58 2.65 0.80 75.0 77.3 74.3 5.4 2 2.6 0.0027 E 23
1.5 90L 1LE0102-0EB42-2..4 IE 1 1425 10 2.1 3.50 0.81 77.2 77.3 75.1 5.6 2 2.5 0.0034 E 26
2.2 100L 1LE0102-1AB42-2..4 IE 1 1425 14.8 2.80 4.95 0.81 79.7 80.7 78.7 5.8 2.4 2.9 0.0063 E 30
3 100L 1LE0102-1AB52-2..4 IE 1 1420 20.2 3.15 6.4 0.83 81.5 83.1 81.5 6.5 2.8 3.1 0.0081 E 33
4 112M 1LE0102-1BB22-2..4 IE 1 1445 26.4 9.2 8.8 0.79 83.1 83.3 81.5 7.4 2.8 3.3 0.011 M 44
5.5 132S 1LE0102-1CB02-2..4 IE 1 1450 36.2 9.7 11.4 0.82 84.7 85.5 84.3 6.5 2 3.1 0.019 K 59
7.5 132M 1LE0102-1CB22-2..4 IE 1 1435 50 12.0 15.4 0.82 86.0 87.2 87.2 6.4 2.3 3.1 0.025 K 70
400 V / 690 VY
2.2 100L 1LE0102-1AB43-4..4 IE 1 1425 14.8 2.70 4.90 0.81 79.7 80.7 78.7 5.8 2.4 2.9 0.0063 E 30
3 100L 1LE0102-1AB53-4..4 IE 1 1420 20.2 3.15 6.4 0.83 81.5 83.1 81.5 6.5 2.8 3.1 0.0081 E 33
4 112M 1LE0102-1BB23-4..4 IE 1 1445 26.4 5.1 8.8 0.79 83.1 83.3 81.5 7.4 2.8 3.3 0.011 M 44
5.5 132S 1LE0102-1CB03-4..4 IE 1 1450 36.2 5.5 11.4 0.82 84.7 85.5 84.3 6.5 2 3.1 0.019 K 59
7.5 132M 1LE0102-1CB23-4..4 IE 1 1435 50 6.5 15.4 0.82 86.0 87.2 87.2 6.4 2.3 3.1 0.025 K 70
11 160M 1LE0102-1DB23-4..4 IE 1 1455 72 9.3 21.5 0.84 87.6 88.5 87.8 6.9 2.2 3.3 0.045 K 99
15 160L 1LE0102-1DB43-4..4 IE 1 1460 98 13.3 29.0 0.84 88.7 89.4 88.6 7.8 2.7 3.8 0.06 L 125
18.5 180M 1LE0102-1EB23-4..4 IE 1 1470 120 13.8 35.0 0.85 89.3 90.3 89.9 7.8 2.7 3.5 0.13 L 163
22 180L 1LE0102-1EB43-4..4 IE 1 1465 143 15.9 41.5 0.85 89.9 90.9 89.9 7.8 2.4 3.2 0.14 L 179
30 200L 1LE0102-2AB43-4..4 IE 1 1470 195 23.0 56 0.85 90.7 91.6 90.5 7.4 2.4 3.1 0.22 K 235
37 225S 1LE0102-2BB03-4..4 IE 1 1470 240 23.5 68 0.86 91.2 91.8 91.0 7.3 2.3 2.8 0.44 K 295
45 225M 1LE0102-2BB23-4..4 IE 1 1475 292 28.5 82 0.87 91.7 92.4 92.0 7.8 2.9 3.3 0.5 K 322
55 250M 1LE0102-2CB23-4..4 IE 1 1478 356 32.5 101 0.86 92.1 92.8 92.0 7.6 3 2.8 0.8 K 410
75 280S 1LE0102-2DB03-4..4 IE 1 1480 484 42.0 133 0.88 92.7 93.3 92.2 7.2 2.6 2.8 1.3 J 540
90 280M 1LE0102-2DB23-4..4 IE 1 1485 579 58 159 0.88 93.0 93.5 92.2 7.8 2.7 2.8 1.4 K 600
110 315S 1LE0102-3AB03-4..4 IE 1 1490 706 70 200 0.85 93.3 93.4 92.5 8.6 2.8 3.1 2.2 L 745
132 315M 1LE0102-3AB23-4..4 IE 1 1488 848 60 235 0.87 93.5 93.8 93.4 7.3 2.5 2.7 2.5 J 875
160 315L 1LE0102-3AB53-4..4 IE 1 1488 1030 83 285 0.87 93.8 94.0 93.6 7.4 3 2.9 3 K 950
185 315L 1LE0102-3AB63-4..4 IE 1 1490 1185 92 325 0.88 93.9 94.1 93.6 7.6 3 2.9 3.6 K 1060
200 315L 1LE0102-3AB73-4..4 IE 1 1488 1285 84 345 0.88 94.0 94.3 94.1 7.4 3 3 3.7 J 1070
220 355M 1LE0102-3BB23-4..4 IE 1 1490 1410 59 380 0.87 95.0 95.1 93.1 6.5 2.1 2.2 6.6 H 1630
250 355M 1LE0102-3BB33-4..4 IE 1 1490 1602 59 435 0.87 95.2 95.2 93.6 6.5 2.1 2.2 6.9 H 1650
280 355L 1LE0102-3BB53-4..4 IE 1 1490 1795 71 485 0.87 95.2 95.2 93.4 6.5 2.1 2.2 7.7 H 1820
315 355L 1LE0102-3BB63-4..4 IE 1 1490 2019 72 550 0.87 95.2 95.3 93.6 6.5 2.1 2.2 8.5 H 1890

Chapter 2 · Motor selection 21


© Siemens AG 2014

SIMOTICS General Purpose (Cast Iron) – IE1


TIP
Cast Iron Series
The nominal torque Efficiency class IE1 IE2
of the motor is easy to calculate; Series 1LE0102 1LE0101
Torque (Nm) = No. of poles 2 4 6 2 4 6
Power (kW) x 9550 / Speed (rpm). Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm

Electrical data - 1LE0 - IE1 - 6-pole (IE1 Cast Iron) 1000 rpm 6-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
230 V / 400 VY
0.55 80M 1LE0102-0DC32-2..4 - 910 5.8 1.04 1.60 0.74 67.5 68.7 65.6 3.8 2.1 2.4 0.0024 C 18.0
0.75 90S 1LE0102-0EC02-2..4 IE 1 925 7.7 1.27 2.10 0.74 70.0 71.5 68.9 3.9 2 2.5 0.0028 C 25
1.1 90L 1LE0102-0EC42-2..4 IE 1 935 11.3 1.89 3.00 0.73 72.9 74.0 71.8 4.4 2.2 2.7 0.0038 D 26
1.5 100L 1LE0102-1AC42-2..4 IE 1 940 15.4 2.30 3.80 0.76 75.2 77.2 74.7 4.6 2.1 2.6 0.0074 D 32
2.2 112M 1LE0102-1BC22-2..4 IE 1 940 22.3 3.00 5.5 0.75 77.7 79.2 78.1 5.2 2.4 3 0.01 E 42
3 132S 1LE0102-1CC02-2..4 IE 1 955 30 4.15 7.5 0.73 79.7 80.9 79.3 5.2 2 2.8 0.018 E 55
4 132M 1LE0102-1CC22-2..4 IE 1 955 40 10.8 9.7 0.73 81.4 82.2 79.4 5.6 2.1 2.9 0.023 K 65
5.5 132M 1LE0102-1CC32-2..4 IE 1 955 55 12.1 12.9 0.74 83.1 84.2 83.0 6 2.3 3.2 0.029 K 73
400 V / 690 VY
1.5 100L 1LE0102-1AC43-4..4 IE 1 940 15.4 2.30 3.80 0.76 75.2 77.2 74.7 4.6 2.1 2.6 0.0074 D 32
2.2 112M 1LE0102-1BC23-4..4 IE 1 940 22.3 3.05 5.4 0.75 77.7 79.2 78.1 5.2 2.4 3 0.01 E 42
3 132S 1LE0102-1CC03-4..4 IE 1 955 30 4.15 7.4 0.73 79.7 80.9 79.3 5.2 2 2.8 0.018 E 55
4 132M 1LE0102-1CC23-4..4 IE 1 955 40 6.2 9.7 0.73 81.4 82.2 79.4 5.6 2.1 2.9 0.023 K 65
5.5 132M 1LE0102-1CC33-4..4 IE 1 955 55 7.3 12.9 0.74 83.1 84.2 83.0 6 2.3 3.2 0.029 K 73
7.5 160M 1LE0102-1DC23-4..4 IE 1 965 74 9.2 16.8 0.76 84.7 85.4 84.5 5.8 2 2.9 0.052 K 101
11 160L 1LE0102-1DC43-4..4 IE 1 965 109 13.3 24.0 0.76 86.4 87.0 86.0 6.6 2.2 3.1 0.072 K 128
15 180L 1LE0102-1EC43-4..4 IE 1 970 148 14.2 32.0 0.78 87.7 88.7 88.4 6.5 2.3 3 0.18 K 169
18.5 200L 1LE0102-2AC43-4..4 IE 1 975 182.1 13.1 36.5 0.82 88.6 90.0 90.1 5.8 2.2 2.8 0.26 J 218
22 200L 1LE0102-2AC53-4..4 IE 1 975 215 15.0 43.0 0.82 89.2 90.5 90.5 6.5 2.3 2.8 0.31 J 237
30 225M 1LE0102-2BC23-4..4 IE 1 978 293 23.0 58 0.83 90.2 91.4 90.5 6.7 2.4 2.8 0.6 K 290
37 250M 1LE0102-2CC23-4..4 IE 1 982 360 26.0 71 0.83 90.8 91.5 91.2 7.5 3 2.8 0.89 K 389
45 280S 1LE0102-2DC03-4..4 IE 1 985 437 28.0 84 0.85 91.4 92.4 92.3 7.1 2.5 2.8 1.1 K 500
55 280M 1LE0102-2DC23-4..4 IE 1 988 532 35.0 102 0.85 91.9 92.6 92.4 7.5 2.4 2.7 1.4 K 525
75 315S 1LE0102-3AC03-4..4 IE 1 988 725 55 141 0.83 92.6 93.0 92.4 7.5 2.4 3 2.3 K 675
90 315M 1LE0102-3AC23-4..4 IE 1 986 872 54 166 0.84 92.9 93.4 93.2 7 2.3 2.8 2.8 K 830
110 315L 1LE0102-3AC53-4..4 IE 1 986 1066 57 200 0.86 93.3 93.9 93.8 6.5 2.2 2.7 3.4 J 915
132 315L 1LE0102-3AC63-4..4 IE 1 988 1278 78 235 0.86 93.5 94.2 93.6 7.8 2.2 2.4 3.9 K 1010
160 355M 1LE0102-3BC23-4..4 IE 1 989 1545 53 275 0.88 94.5 94.6 92.4 6.5 2 2.1 7.7 H 1640
185 355M 1LE0102-3BC33-4..4 IE 1 989 1786 55 320 0.88 94.5 94.6 92.6 6.5 2 2.1 8.4 H 1680
200 355M 1LE0102-3BC43-4..4 IE 1 989 1931 60 345 0.88 94.7 94.7 93.4 6.5 2 2.1 9.1 H 1720
220 355L 1LE0102-3BC53-4..4 IE 1 989 2124 68 380 0.88 94.7 94.7 92.6 6.5 2 2.1 10.1 H 1840
250 355L 1LE0102-3BC63-4..4 IE 1 989 2414 80 430 0.88 94.7 94.7 93.4 6.5 2 2.1 11.4 H 1920

22 Chapter 2 · Motor selection


© Siemens AG 2014

SIMOTICS General Purpose (Cast Iron) – IE2


Cast Iron Series
Efficiency class IE1 IE2
Series 1LE0102 1LE0101
No. of poles 2 4 6 2 4 6
Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm

Electrical data - 1LE0 - IE2 - 2-pole (IE2 Cast Iron) 3000 rpm 2-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
230 V / 400 VY
0.75 80M 1LE0101-0DA22-2..4 IE 2 2795 2.6 0.70 1.67 0.84 77.4 78.5 78.5 5.6 2.4 2.4 0.00080 D 15.5
1.1 80M 1LE0101-0DA32-2..4 IE 2 2835 3.7 1.13 2.40 0.84 79.6 80.6 77.4 6.0 2.8 3.2 0.0012 E 17.5
1.5 90S 1LE0101-0EA02-2..4 IE 2 2890 5.0 1.52 3.20 0.84 81.3 81.7 78.0 6.5 2.4 3.1 0.0021 E 23
2.2 90L 1LE0101-0EA42-2..4 IE 2 2890 7.3 2.30 4.55 0.85 83.2 83.7 80.8 7.2 2.6 3.5 0.0026 F 26
3 100L 1LE0101-1AA42-2..4 IE 2 2885 9.9 2.85 6.1 0.84 84.6 85.1 84.1 7.5 4.0 4.5 0.0036 F 34
4 112M 1LE0101-1BA22-2..4 IE 2 2930 13.0 5.9 7.8 0.86 85.8 86.6 84.7 7.5 2.2 2.9 0.0064 L 40
5.5 132S 1LE0101-1CA02-2.B4 IE 2 2930 17.9 6.9 10.5 0.87 87.0 87.6 86.9 7.5 2.2 2.9 0.014 K 56
7.5 132S 1LE0101-1CA12-2.B4 IE 2 2930 24.4 8.4 13.8 0.89 88.1 88.8 88.5 7.5 2.3 2.9 0.017 K 62
400 V / 690 VY
3 100L 1LE0101-1AA43-4..4 IE 2 2885 9.9 2.85 6.1 0.84 84.6 85.1 84.1 7.5 4 4.5 0.0036 F 34
4 112M 1LE0101-1BA23-4..4 IE 2 2930 13.0 3.70 7.8 0.86 85.8 86.6 84.7 7.5 2.2 2.9 0.0064 L 40
5.5 132S 1LE0101-1CA03-4.B4 IE 2 2930 17.9 4.30 10.5 0.87 87.0 87.6 86.9 7.5 2.2 2.9 0.014 K 56
7.5 132S 1LE0101-1CA13-4.B4 IE 2 2930 24.4 4.65 13.8 0.89 88.1 88.8 88.5 7.5 2.3 2.9 0.017 K 62
11 160M 1LE0101-1DA23-4.B4 IE 2 2935 35.8 8.1 20.5 0.86 89.4 90.1 89.3 7.5 2.2 2.9 0.031 K 96
15 160M 1LE0101-1DA33-4.B4 IE 2 2935 48.8 10.4 28 0.86 90.3 91.0 90.5 7.5 2.4 3.2 0.038 K 106
18.5 160L 1LE0101-1DA43-4.B4 IE 2 2935 60.2 10.3 33 0.89 90.9 91.7 91.5 7.5 2.4 3.2 0.046 K 125
22 180M 1LE0101-1EA23-4.B4 IE 2 2935 71.6 13.5 40 0.87 91.3 91.8 91.1 7.6 2.5 3.2 0.072 K 152
30 200L 1LE0101-2AA43-4.B4 IE 2 2955 97.0 18.0 55 0.86 92.0 92.3 91.5 7.5 2.5 3.2 0.13 K 229
37 200L 1LE0101-2AA53-4.B4 IE 2 2955 120 19.0 66 0.88 92.5 92.8 92.3 7.5 2.5 3.2 0.15 K 245
45 225M 1LE0101-2BA23-4.B4 IE 2 2965 145 23.0 80 0.88 92.9 93.1 92.5 7.9 2.5 3.1 0.24 K 307
55 250M 1LE0101-2CA23-4.B4 IE 2 2970 177 28.5 97 0.88 93.2 93.2 91.8 7.5 2.5 3 0.42 K 378
75 280S 1LE0101-2DA03-4.B4 IE 2 2975 241 41.0 133 0.87 93.8 93.8 92.7 7.5 2.8 3 0.75 K 550
90 280M 1LE0101-2DA23-4.B4 IE 2 2978 289 49.5 159 0.87 94.1 94.1 92.9 7.5 3 3.1 0.88 K 570
110 315S 1LE0101-3AA03-4.B4 IE 2 2982 352 47.5 187 0.90 94.3 94.3 93.3 7.5 2.2 2.6 1.4 J 740
132 315M 1LE0101-3AA23-4.B4 IE 2 2982 423 46.5 220 0.91 94.6 94.6 93.9 7.5 2.3 2.9 1.7 J 855
160 315L 1LE0101-3AA53-4.B4 IE 2 2982 512 52 265 0.92 94.8 95.1 94.1 7.5 2.5 2.8 1.9 J 970
185 315L 1LE0101-3AA63-4.B4 IE 2 2982 592 64 305 0.92 95.0 95.3 94.2 7.5 2.5 2.8 2.3 J 1080
200 315L 1LE0101-3AA73-4.B4 IE 2 2982 641 64 330 0.92 95.0 95.3 94.4 7.5 2.5 2.8 2.3 J 1090
220 355M 1LE0101-3BA23-4.B4 IE 2 2980 705 50 370 0.90 95.0 95.0 92.8 7.1 2 2.2 2.9 J 1600
250 355M 1LE0101-3BA33-4.B4 IE 2 2980 801 46 420 0.90 95.0 95.0 93.0 7.1 2 2.2 3 J 1650
280 355L 1LE0101-3BA53-4.B4 IE 2 2980 897 56 475 0.90 95.0 95.1 93.0 7.1 2 2.2 3.5 J 1830
315 355L 1LE0101-3BA63-4.B4 IE 2 2980 1009 57 530 0.90 95.0 95.1 93.1 7.1 2 2.3 3.5 J 1840

Chapter 2 · Motor selection 23


© Siemens AG 2014

SIMOTICS General Purpose (Cast Iron) – IE2


TIP
Cast Iron Series
The nominal torque Efficiency class IE1 IE2
of the motor is easy to calculate; Series 1LE0102 1LE0101
Torque (Nm) = No. of poles 2 4 6 2 4 6
Power (kW) x 9550 / Speed (rpm). Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm

Electrical data - 1LE0 - IE2 - 4-pole (IE2 Cast Iron) 1500 rpm 4-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
230 V / 400 VY
0.55 80M 1LE0101-0DB22-2..4 - 1425 3.7 0.80 1.34 0.80 74.0 74.7 70.1 6.0 2.0 2.7 0.0021 F 17.5
0.75 80M 1LE0101-0DB32-2..4 IE 2 1440 5.0 1.00 1.82 0.75 79.6 79.6 76.8 6.5 2.8 3.5 0.0027 F 19
1.1 90S 1LE0101-0EB02-2..4 IE 2 1440 7.3 1.60 2.65 0.75 81.4 81.4 77.6 7.0 2.8 3.5 0.0041 G 24
1.5 90L 1LE0101-0EB42-2..4 IE 2 1440 9.9 2.05 3.45 0.76 82.8 82.8 80.2 7.0 3.0 3.8 0.0047 G 27
2.2 100L 1LE0101-1AB42-2..4 IE 2 1435 14.6 2.65 4.8 0.79 84.3 85.0 83.1 7.0 3.0 3.2 0.0081 F 33
3 100L 1LE0101-1AB52-2..4 IE 2 1435 20.0 3.50 6.4 0.79 85.5 86.3 84.2 7.0 3.0 3.2 0.01 F 37
4 112M 1LE0101-1BB22-2..4 IE 2 1445 26.4 7.6 8.4 0.79 86.6 87.1 85.8 7.1 2.7 3.1 0.011 L 45
5.5 132S 1LE0101-1CB02-2.B4 IE 2 1460 36.0 10.6 11.5 0.79 87.7 88.2 86.9 7.5 2.5 3.1 0.021 L 61
7.5 132M 1LE0101-1CB22-2.B4 IE 2 1460 49.1 11.5 14.9 0.82 88.7 89.4 88.8 7.7 2.7 3.2 0.029 L 73
400 V / 690 VY
2.2 100L 1LE0101-1AB43-4..4 IE 2 1435 14.6 2.6 4.75 0.79 84.3 85.0 83.1 7.0 3.0 3.2 0.0081 F 33
3 100L 1LE0101-1AB53-4..4 IE 2 1435 20.0 3.55 6.4 0.79 85.5 86.3 84.2 7.0 3.0 3.2 0.010 F 37
4 112M 1LE0101-1BB23-4..4 IE 2 1445 26.4 4.45 8.455 0.79 86.6 87.1 85.8 7.1 2.7 3.1 0.011 L 45
5.5 132S 1LE0101-1CB03-4.B4 IE 2 1460 36.0 6.1 11.495 0.79 87.7 88.2 86.9 7.5 2.5 3.1 0.021 L 61
7.5 132M 1LE0101-1CB23-4.B4 IE 2 1460 49.1 6.7 14.915 0.82 88.7 89.4 88.8 7.7 2.7 3.2 0.029 L 73
11 160M 1LE0101-1DB23-4.B4 IE 2 1465 71.7 6.7 21 0.84 89.8 90.4 90.1 7.5 2.5 3.1 0.051 K 103
15 160L 1LE0101-1DB43-4.B4 IE 2 1465 97.8 11.8 28.025 0.85 90.6 91.3 90.6 7.8 2.7 3.2 0.066 K 130
18.5 180M 1LE0101-1EB23-4.B4 IE 2 1465 121 12.3 34.5 0.85 91.2 91.8 91.8 7.3 2.5 3.2 0.13 K 165
22 180L 1LE0101-1EB43-4.B4 IE 2 1465 143 15.4 41 0.85 91.6 92.3 92.7 7.3 2.4 3.2 0.14 K 180
30 200L 1LE0101-2AB43-4.B4 IE 2 1470 195 19.0 55 0.85 92.3 92.9 92.9 7.3 2.7 3.2 0.22 K 238
37 225S 1LE0101-2BB03-4.B4 IE 2 1475 240 23.0 67 0.86 92.7 93.2 92.9 7.3 2.7 3.2 0.45 K 298
45 225M 1LE0101-2BB23-4.B4 IE 2 1475 291 26.0 80 0.87 93.1 93.5 93.9 7.3 2.7 3.2 0.51 K 322
55 250M 1LE0101-2CB23-4.B4 IE 2 1480 355 32.0 99 0.86 93.5 93.9 93.3 7.5 3.1 3.5 0.8 K 410
75 280S 1LE0101-2DB03-4.B4 IE 2 1485 482 45.0 132 0.87 94.0 94.3 93.9 7.5 2.7 3.1 1.4 K 555
90 280M 1LE0101-2DB23-4.B4 IE 2 1485 579 57 159 0.87 94.2 94.3 94.2 7.5 2.7 3.1 1.5 K 610
110 315S 1LE0101-3AB03-4.B4 IE 2 1488 706 67 195 0.86 94.5 94.5 93.9 7.3 2.8 2.9 2.2 K 750
132 315M 1LE0101-3AB23-4.B4 IE 2 1486 848 56 230 0.88 94.7 94.7 95.0 7.3 2.5 2.7 2.5 J 875
160 315L 1LE0101-3AB53-4.B4 IE 2 1488 1027 77 275 0.88 94.9 94.9 95.1 7.4 3.0 2.9 3.0 J 960
185 315L 1LE0101-3AB63-4.B4 IE 2 1488 1187 86 320 0.88 95.1 95.1 95.0 7.4 3.0 3.0 3.6 J 1070
200 315L 1LE0101-3AB73-4.B4 IE 2 1488 1284 86 345 0.88 95.1 95.1 95.1 7.4 3.0 3.0 3.7 J 1080
220 355M 1LE0101-3BB23-4.B4 IE 2 1490 1410 69 370 0.90 95.1 95.2 93.3 6.9 2.0 2.2 6.6 J 1640
250 355M 1LE0101-3BB33-4.B4 IE 2 1490 1602 61 420 0.90 95.1 95.2 93.8 6.9 2.0 2.2 6.9 J 1680
280 355L 1LE0101-3BB53-4.B4 IE 2 1490 1795 66 470 0.90 95.1 95.2 93.8 6.9 2.0 2.2 7.7 J 1830
315 355L 1LE0101-3BB63-4.B4 IE 2 1490 2019 75 530 0.90 95.1 95.2 93.8 6.9 2.0 2.2 8.5 J 1900

24 Chapter 2 · Motor selection


© Siemens AG 2014

SIMOTICS General Purpose (Cast Iron) – IE2


Cast Iron Series
Efficiency class IE1 IE2
Series 1LE0102 1LE0101
No. of poles 2 4 6 2 4 6
Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm

Electrical data - 1LE0 - IE2 - 6-pole (IE2 Cast Iron) 1000 rpm 6-pole, 400 V 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
230 V / 400 VY
0.55 80M 1LE0101-0DC32-2..4 - 895 5.9 1.08 1.48 0.76 71.0 72.0 68.5 3.8 2.1 2.4 0.0028 C 18.5
0.75 90S 1LE0101-0EC02-2..4 IE 2 935 7.7 1.27 2.00 0.71 75.9 76.5 72.7 3.9 2.0 2.5 0.0038 C 26
1.1 90L 1LE0101-0EC42-2..4 IE 2 945 11.1 2.00 2.85 0.71 78.1 78.1 75.7 4.4 2.2 2.7 0.0046 D 27
1.5 100L 1LE0101-1AC42-2..4 IE 2 945 15.2 2.45 3.70 0.74 79.8 80.1 78.2 4.6 2.1 2.6 0.0086 D 34
2.2 112M 1LE0101-1BC22-2..4 IE 2 950 22.1 2.90 5.4 0.73 81.8 82.5 81.0 5.2 2.4 3.0 0.012 E 44
3 132S 1LE0101-1CC02-2..4 IE 2 960 29.8 3.70 7.2 0.73 83.3 84.3 83.4 5.2 2.0 2.8 0.019 E 56
4 132M 1LE0101-1CC22-2..4 IE 2 960 39.8 8.7 9.4 0.73 84.6 85.4 84.5 5.6 2.1 2.9 0.024 K 66
5.5 132M 1LE0101-1CC32-2.B4 IE 2 960 54.7 12.6 12.3 0.75 86.0 86.6 85.7 6.0 2.3 3.2 0.031 K 75
400 V / 690 VY
1.5 100L 1LE0101-1AC43-4..4 IE 2 945 15.2 2.40 3.65 0.74 79.8 80.1 78.2 4.6 2.1 2.6 0.0086 D 34
2.2 112M 1LE0101-1BC23-4..4 IE 2 950 22.1 2.90 5.3 0.73 81.8 82.5 81.0 5.2 2.4 3.0 0.012 E 44
3 132S 1LE0101-1CC03-4..4 IE 2 960 29.8 3.70 7.1 0.73 83.3 84.3 83.4 5.2 2.0 2.8 0.019 D 56
4 132M 1LE0101-1CC23-4..4 IE 2 960 39.8 5.0 9.3 0.73 84.6 85.4 84.5 5.6 2.1 2.9 0.024 K 66
5.5 132M 1LE0101-1CC33-4.B4 IE 2 960 54.7 6.8 12.4 0.75 86.0 86.6 85.7 6.0 2.3 3.2 0.031 K 75
7.5 160M 1LE0101-1DC23-4.B4 IE 2 965 74.2 7.9 16.2 0.77 87.2 87.9 87.2 5.8 2.0 2.9 0.056 J 104
11 160L 1LE0101-1DC43-4.B4 IE 2 965 109 10.7 23.0 0.78 88.7 89.4 89.5 6.6 2.2 3.1 0.077 K 132
15 180L 1LE0101-1EC43-4.B4 IE 2 975 147 14.8 31.0 0.78 89.7 90.4 89.9 6.5 2.3 3.0 0.18 K 170
18.5 200L 1LE0101-2AC43-4.B4 IE 2 975 181 13.8 36.5 0.81 90.4 91.0 91.8 5.8 2.2 2.8 0.27 J 220
22 200L 1LE0101-2AC53-4.B4 IE 2 975 215 16.4 43.0 0.82 90.9 91.4 91.9 6.5 2.3 2.8 0.32 J 240
30 225M 1LE0101-2BC23-4.B4 IE 2 980 292 19.5 57 0.83 91.7 92.3 92.7 6.7 2.4 2.8 0.62 J 294
37 250M 1LE0101-2CC23-4.B4 IE 2 982 360 23.0 69 0.83 92.2 92.8 92.3 7.5 3.0 2.8 0.91 K 394
45 280S 1LE0101-2DC03-4.B4 IE 2 985 436 28.0 83 0.85 92.7 93.3 93.5 7.1 2.5 2.8 1.2 K 510
55 280M 1LE0101-2DC23-4.B4 IE 2 986 533 34.5 101 0.85 93.1 93.7 93.6 7.5 2.4 2.7 1.5 K 535
75 315S 1LE0101-3AC03-4.B4 IE 2 986 726 53 136 0.85 93.7 94.3 93.8 7.5 2.4 3.0 2.3 K 680
90 315M 1LE0101-3AC23-4.B4 IE 2 986 872 51 163 0.85 94.0 94.5 94.4 7.0 2.3 2.8 2.8 J 835
110 315L 1LE0101-3AC53-4.B4 IE 2 988 1063 57 195 0.86 94.3 94.7 94.6 6.5 2.2 2.7 3.9 J 975
132 315L 1LE0101-3AC63-4.B4 IE 2 988 1276 69 230 0.86 94.6 95.0 94.9 7.8 2.2 2.4 4.3 K 1030
160 355M 1LE0101-3BC23-4.B4 IE 2 990 1543 50 280 0.87 94.8 95.1 93.5 6.5 2.0 2.1 7.7 J 1650
185 355M 1LE0101-3BC33-4.B4 IE 2 990 1785 57 325 0.87 95.0 95.3 93.5 6.5 2.0 2.1 8.4 J 1690
200 355M 1LE0101-3BC43-4.B4 IE 2 990 1929 56 350 0.87 95.0 95.3 93.6 6.5 2.0 2.1 9.1 J 1730
220 355L 1LE0101-3BC53-4.B4 IE 2 990 2122 64 385 0.87 95.0 95.3 93.5 6.5 2.0 2.1 10.1 J 1850
250 355L 1LE0101-3BC63-4.B4 IE 2 990 2412 73 435 0.87 95.0 95.3 93.5 6.5 2.0 2.1 11.4 J 1930

Chapter 2 · Motor selection 25


© Siemens AG 2014

SIMOTICS General Purpose (Cast Iron) – IE1


TIP
Cast Iron Series
The nominal torque Efficiency class IE1 IE2
of the motor is easy to calculate; Series 1LE0102 1LE0101
Torque (Nm) = No. of poles 2 4 6 2 4 6
Power (kW) x 9550 / Speed (rpm). Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm

Electrical data - 1LE0 - IE1 - 2-pole (IE1 Cast Iron) 3000 rpm 2-pole, 525 VΔ 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
0.75 80M 1LE0102-0DA24-1..4 IE 1 2800 2.6 0.72 1.33 0.86 72.1 73.0 71.1 5.1 2.3 2.7 0.0008 D 15.0
1.1 80M 1LE0102-0DA34-1..4 IE 1 2830 3.7 0.88 1.88 0.86 75.0 77.3 74.4 6.0 2.6 3.1 0.001 E 17.5
1.5 90S 1LE0102-0EA04-1..4 IE 1 2885 5 1.39 2.50 0.85 77.2 76.9 73.5 6.9 2.5 3.2 0.0017 F 22
2.2 90L 1LE0102-0EA44-1..4 IE 1 2885 7.3 1.64 3.50 0.87 79.7 80.5 78.1 7.5 2.7 3.4 0.0022 F 26
3 100L 1LE0102-1AA44-1..4 IE 1 2850 10 2.10 4.80 0.85 81.5 82.1 79.9 6.9 3 3.7 0.0033 F 33
4 112M 1LE0102-1BA24-1..4 IE 1 2910 13.1 2.90 6.2 0.85 83.1 83.7 81.5 7.8 2.9 4.2 0.0064 L 39
5.5 132S 1LE0102-1CA04-1..4 IE 1 2915 18 3.85 8.3 0.86 84.7 85.3 83.7 6.9 2 3.1 0.013 K 55
7.5 132S 1LE0102-1CA14-1..4 IE 1 2920 24.5 4.50 10.9 0.88 86.0 87.2 86.2 7.1 2 2.9 0.015 K 60
11 160M 1LE0102-1DA24-1..4 IE 1 2925 35.9 7.1 16.3 0.84 87.6 88.2 87.1 6.3 2 3.1 0.028 J 93
15 160M 1LE0102-1DA34-1..4 IE 1 2930 48.9 9.2 21.5 0.85 88.7 89.3 87.4 7 2.2 3.2 0.034 K 101
18.5 160L 1LE0102-1DA44-1..4 IE 1 2935 60 10.7 26.5 0.86 89.3 89.9 89.1 7.6 2.5 3.4 0.041 K 120
22 180M 1LE0102-1EA24-1..4 IE 1 2925 72 10.1 31.0 0.87 89.9 90.6 90.0 7.6 2.7 3.5 0.072 K 151
30 200L 1LE0102-2AA44-1..4 IE 1 2950 97 14.3 42.0 0.87 90.7 90.8 89.0 7.5 2.5 3.2 0.12 K 224
37 200L 1LE0102-2AA54-1..4 IE 1 2950 120 14.8 51 0.88 91.2 91.6 90.4 7.4 2.6 3.2 0.15 K 242
45 225M 1LE0102-2BA24-1..4 IE 1 2960 145 18.5 62 0.88 91.7 91.9 90.5 7.6 2.8 3.3 0.23 K 304
55 250M 1LE0102-2CA24-1..4 IE 1 2970 177 24.5 75 0.88 92.1 92.4 90.7 7.7 2.5 3.1 0.4 K 374
75 280S 1LE0102-2DA04-1..4 IE 1 2970 241 32.0 102 0.87 92.7 92.6 91.1 6.7 2.7 3 0.7 J 540
90 280M 1LE0102-2DA24-1..4 IE 1 2975 289 36.0 121 0.88 93.0 93.2 91.3 7.2 2.8 3 0.82 J 560
110 315S 1LE0102-3AA04-1..4 IE 1 2982 353 37.5 144 0.90 93.3 93.1 91.2 7.5 2.2 3.1 1.4 K 735
132 315M 1LE0102-3AA24-1..4 IE 1 2980 423 35.0 170 0.92 93.5 93.1 91.7 7.5 2.3 2.9 1.7 J 850
160 315L 1LE0102-3AA54-1..4 IE 1 2982 513 42.5 205 0.92 93.8 93.6 92.5 7.6 2.5 2.8 1.9 J 960
185 315L 1LE0102-3AA64-1..4 IE 1 2978 594 38.5 235 0.92 93.9 93.9 93.1 7.5 2.4 2.8 2.3 J 1070
200 315L 1LE0102-3AA74-1..4 IE 1 2980 641 49.0 255 0.92 94.0 94.3 93.2 7.9 2.5 2.6 2.3 K 1080
220 355M 1LE0102-3BA24-1..4 IE 1 2985 704 32.5 280 0.90 94.8 95.0 92.8 6.5 2 2.1 2.9 H 1590
250 355M 1LE0102-3BA34-1..4 IE 1 2985 800 41.5 320 0.90 95.2 95.2 93.0 6.5 2 2.1 3 H 1620
280 355L 1LE0102-3BA54-1..4 IE 1 2985 896 43.5 360 0.90 95.2 95.2 92.9 6.5 2 2.1 3.5 H 1820
315 355L 1LE0102-3BA64-1..4 IE 1 2985 1008 46.5 405 0.90 95.4 95.4 93.2 6.5 2 2.1 3.5 H 1830

Electrical data - 1LE0 - IE1 - 4-pole (IE1 Cast Iron) 1500 rpm 4-pole, 525 VΔ 50 Hz
0.55 80M 1LE0102-0DB24-1..4 - 1415 3.7 0.58 1.08 0.81 69.4 69.9 66.8 4.5 2 2.6 0.0016 D 17.0
0.75 80M 1LE0102-0DB34-1..4 IE 1 1405 5.1 0.75 1.41 0.81 72.1 73.7 71.8 4.8 2 2.6 0.0019 D 18.5
1.1 90S 1LE0102-0EB04-1..4 IE 1 1420 7.4 1.20 2.05 0.80 75.0 77.3 74.3 5.4 2 2.6 0.0027 E 23
1.5 90L 1LE0102-0EB44-1..4 IE 1 1425 10 1.59 2.65 0.81 77.2 77.3 75.1 5.6 2 2.5 0.0034 E 26
2.2 100L 1LE0102-1AB44-1..4 IE 1 1425 14.8 2.05 3.75 0.81 79.7 80.7 78.7 5.8 2.4 2.9 0.0063 E 30
3 100L 1LE0102-1AB54-1..4 IE 1 1420 20.2 2.40 4.85 0.83 81.5 83.1 81.5 6.5 2.8 3.1 0.0081 E 33
4 112M 1LE0102-1BB24-1..4 IE 1 1445 26.4 3.90 6.7 0.79 83.1 83.3 81.5 7.4 2.8 3.3 0.011 M 44
5.5 132S 1LE0102-1CB04-1..4 IE 1 1450 36.2 4.20 8.7 0.82 84.7 85.5 84.3 6.5 2 3.1 0.019 K 59
7.5 132M 1LE0102-1CB24-1..4 IE 1 1435 50 4.90 11.7 0.82 86.0 87.2 87.2 6.4 2.3 3.1 0.025 K 70
11 160M 1LE0102-1DB24-1..4 IE 1 1455 72 7.1 16.3 0.84 87.6 88.5 87.8 6.9 2.2 3.3 0.045 K 99
15 160L 1LE0102-1DB44-1..4 IE 1 1460 98 10.1 22.0 0.84 88.7 89.4 88.6 7.8 2.7 3.8 0.06 L 125
18.5 180M 1LE0102-1EB24-1..4 IE 1 1470 120 10.5 27.0 0.85 89.3 90.3 89.9 7.8 2.7 3.5 0.13 L 163
22 180L 1LE0102-1EB44-1..4 IE 1 1465 143 12.1 31.5 0.85 89.9 90.9 89.9 7.8 2.4 3.2 0.14 L 179
30 200L 1LE0102-2AB44-1..4 IE 1 1470 195 17.4 42.5 0.85 90.7 91.6 90.5 7.4 2.4 3.1 0.22 K 235
37 225S 1LE0102-2BB04-1..4 IE 1 1470 240 17.7 52 0.86 91.2 91.8 91.0 7.3 2.3 2.8 0.44 K 295

26 Chapter 2 · Motor selection


© Siemens AG 2014

SIMOTICS General Purpose (Cast Iron) – IE1


Cast Iron Series
Efficiency class IE1 IE2
Series 1LE0102 1LE0101
No. of poles 2 4 6 2 4 6
Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm

Electrical data - 1LE0 - IE1 - 4-pole (IE1 Cast Iron) 1500 rpm 4-pole, 525 VΔ 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
45 225M 1LE0102-2BB24-1..4 IE 1 1475 292 21.5 62 0.87 91.7 92.4 92.0 7.8 2.9 3.3 0.5 K 322
55 250M 1LE0102-2CB24-1..4 IE 1 1478 356 24.5 77 0.86 92.1 92.8 92.0 7.6 3 2.8 0.8 K 410
75 280S 1LE0102-2DB04-1..4 IE 1 1480 484 32.0 101 0.88 92.7 93.3 92.2 7.2 2.6 2.8 1.3 J 540
90 280M 1LE0102-2DB24-1..4 IE 1 1485 579 44.0 121 0.88 93.0 93.5 92.2 7.8 2.7 2.8 1.4 K 600
110 315S 1LE0102-3AB04-1..4 IE 1 1490 706 54 153 0.85 93.3 93.4 92.5 8.6 2.8 3.1 2.2 L 745
132 315M 1LE0102-3AB24-1..4 IE 1 1488 848 45.5 177 0.87 93.5 93.8 93.4 7.3 2.5 2.7 2.5 J 875
160 315L 1LE0102-3AB54-1..4 IE 1 1488 1030 63 215 0.87 93.8 94.0 93.6 7.4 3 2.9 3 K 950
185 315L 1LE0102-3AB64-1..4 IE 1 1490 1185 70 245 0.88 93.9 94.1 93.6 7.6 3 2.9 3.6 K 1060
200 315L 1LE0102-3AB74-1..4 IE 1 1488 1285 64 265 0.88 94.0 94.3 94.1 7.4 3 3 3.7 J 1070
220 355M 1LE0102-3BB24-1..4 IE 1 1490 1410 45.0 290 0.87 95.0 95.1 93.1 6.5 2.1 2.2 6.6 H 1630
250 355M 1LE0102-3BB34-1..4 IE 1 1490 1602 45.5 330 0.87 95.2 95.2 93.6 6.5 2.1 2.2 6.9 H 1650
280 355L 1LE0102-3BB54-1..4 IE 1 1490 1795 54 370 0.87 95.2 95.2 93.4 6.5 2.1 2.2 7.7 H 1820
315 355L 1LE0102-3BB64-1..4 IE 1 1490 2019 55 420 0.87 95.2 95.3 93.6 6.5 2.1 2.2 8.5 H 1890

Electrical data - 1LE0 - IE1 - 6-pole (IE1 Cast Iron) 1000 rpm 6-pole, 525 VΔ 50 Hz
0.55 80M 1LE0102-0DC34-1..4 - 910 5.8 0.79 1.21 0.74 67.5 68.7 65.6 3.8 2.1 2.4 0.0024 C 18.0
0.75 90S 1LE0102-0EC04-1..4 IE 1 925 7.7 0.97 1.59 0.74 70.0 71.5 68.9 3.9 2 2.5 0.0028 C 25
1.1 90L 1LE0102-0EC44-1..4 IE 1 935 11.3 1.44 2.30 0.73 72.9 74.0 71.8 4.4 2.2 2.7 0.0038 D 26
1.5 100L 1LE0102-1AC44-1..4 IE 1 940 15.4 1.74 2.90 0.76 75.2 77.2 74.7 4.6 2.1 2.6 0.0074 D 32
2.2 112M 1LE0102-1BC24-1..4 IE 1 940 22.3 2.30 4.15 0.75 77.7 79.2 78.1 5.2 2.4 3 0.01 E 42
3 132S 1LE0102-1CC04-1..4 IE 1 955 30 3.15 5.7 0.73 79.7 80.9 79.3 5.2 2 2.8 0.018 E 55
4 132M 1LE0102-1CC24-1..4 IE 1 955 40 4.70 7.4 0.73 81.4 82.2 79.4 5.6 2.1 2.9 0.023 K 65
5.5 132M 1LE0102-1CC34-1..4 IE 1 955 55 5.6 9.8 0.74 83.1 84.2 83.0 6 2.3 3.2 0.029 K 73
7.5 160M 1LE0102-1DC24-1..4 IE 1 965 74 7.0 12.8 0.76 84.7 85.4 84.5 5.8 2 2.9 0.052 K 101
11 160L 1LE0102-1DC44-1..4 IE 1 965 109 10.1 18.5 0.76 86.4 87.0 86.0 6.6 2.2 3.1 0.072 K 128
15 180L 1LE0102-1EC44-1..4 IE 1 970 148 10.8 24.5 0.78 87.7 88.7 88.4 6.5 2.3 3 0.18 K 169
18.5 200L 1LE0102-2AC44-1..4 IE 1 975 182.1 10.0 28.0 0.82 88.6 90.0 90.1 5.8 2.2 2.8 0.26 J 218
22 200L 1LE0102-2AC54-1..4 IE 1 975 215 11.4 33.0 0.82 89.2 90.5 90.5 6.5 2.3 2.8 0.31 J 237
30 225M 1LE0102-2BC24-1..4 IE 1 978 293 17.4 44.0 0.83 90.2 91.4 90.5 6.7 2.4 2.8 0.6 K 290
37 250M 1LE0102-2CC24-1..4 IE 1 982 360 20.0 54 0.83 90.8 91.5 91.2 7.5 3 2.8 0.89 K 389
45 280S 1LE0102-2DC04-1..4 IE 1 985 437 21.5 64 0.85 91.4 92.4 92.3 7.1 2.5 2.8 1.1 K 500
55 280M 1LE0102-2DC24-1..4 IE 1 988 532 27.0 77 0.85 91.9 92.6 92.4 7.5 2.4 2.7 1.4 K 525
75 315S 1LE0102-3AC04-1..4 IE 1 988 725 42.0 107 0.83 92.6 93.0 92.4 7.5 2.4 3 2.3 K 675
90 315M 1LE0102-3AC24-1..4 IE 1 986 872 41.5 127 0.84 92.9 93.4 93.2 7 2.3 2.8 2.8 K 830
110 315L 1LE0102-3AC54-1..4 IE 1 986 1066 43.5 152 0.86 93.3 93.9 93.8 6.5 2.2 2.7 3.4 J 915
132 315L 1LE0102-3AC64-1..4 IE 1 988 1278 59 181 0.86 93.5 94.2 93.6 7.8 2.2 2.4 3.9 K 1010
160 355M 1LE0102-3BC24-1..4 IE 1 989 1545 40.5 210 0.88 94.5 94.6 92.4 6.5 2 2.1 7.7 H 1640
185 355M 1LE0102-3BC34-1..4 IE 1 989 1786 42.0 240 0.88 94.5 94.6 92.6 6.5 2 2.1 8.4 H 1680
200 355M 1LE0102-3BC44-1..4 IE 1 989 1931 45.5 260 0.88 94.7 94.7 93.4 6.5 2 2.1 9.1 H 1720
220 355L 1LE0102-3BC54-1..4 IE 1 989 2124 52 290 0.88 94.7 94.7 92.6 6.5 2 2.1 10.1 H 1840
250 355L 1LE0102-3BC64-1..4 IE 1 989 2414 61 330 0.88 94.7 94.7 93.4 6.5 2 2.1 11.4 H 1920

Chapter 2 · Motor selection 27


© Siemens AG 2014

SIMOTICS General Purpose (Cast Iron) – IE2


TIP
Cast Iron Series
The nominal torque Efficiency class IE1 IE2
of the motor is easy to calculate; Series 1LE0102 1LE0101
Torque (Nm) = No. of poles 2 4 6 2 4 6
Power (kW) x 9550 / Speed (rpm). Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm

Electrical data - 1LE0 - IE2 - 2-pole (IE2 Cast Iron) 3000 rpm 2-pole, 525 VΔ 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
0.75 80M 1LE0101-0DA24-1..4 IE 2 2795 2.6 0.54 1.27 0.84 77.4 78.5 78.5 5.6 2.4 2.4 0.00080 D 15.5
1.1 80M 1LE0101-0DA34-1..4 IE 2 2835 3.7 0.86 1.81 0.84 79.6 80.6 77.4 6.0 2.8 3.2 0.0012 E 17.5
1.5 90S 1LE0101-0EA04-1..4 IE 2 2890 5.0 1.16 2.40 0.84 81.3 81.7 78.0 6.5 2.4 3.1 0.0021 E 23
2.2 90L 1LE0101-0EA44-1..4 IE 2 2890 7.3 1.74 3.45 0.85 83.2 83.7 80.8 7.2 2.6 3.5 0.0026 F 26
3 100L 1LE0101-1AA44-1..4 IE 2 2885 9.9 2.15 4.65 0.84 84.6 85.1 84.1 7.5 4 4.5 0.0036 F 34
4 112M 1LE0101-1BA24-1..4 IE 2 2930 13.0 2.80 5.9 0.86 85.8 86.6 84.7 7.5 2.2 2.9 0.0064 L 40
5.5 132S 1LE0101-1CA04-1.B4 IE 2 2930 17.9 3.25 8.0 0.87 87.0 87.6 86.9 7.5 2.2 2.9 0.014 K 56
7.5 132S 1LE0101-1CA14-1.B4 IE 2 2930 24.4 3.55 10.5 0.89 88.1 88.8 88.5 7.5 2.3 2.9 0.017 K 62
11 160M 1LE0101-1DA24-1.B4 IE 2 2935 35.8 6.2 15.6 0.86 89.4 90.1 89.3 7.5 2.2 2.9 0.031 K 96
15 160M 1LE0101-1DA34-1.B4 IE 2 2935 48.8 7.9 21.5 0.86 90.3 91.0 90.5 7.5 2.4 3.2 0.038 K 106
18.5 160L 1LE0101-1DA44-1.B4 IE 2 2935 60.2 7.8 25.0 0.89 90.9 91.7 91.5 7.5 2.4 3.2 0.046 K 125
22 180M 1LE0101-1EA24-1.B4 IE 2 2935 71.6 10.3 30.5 0.87 91.3 91.8 91.1 7.6 2.5 3.2 0.072 K 152
30 200L 1LE0101-2AA44-1.B4 IE 2 2955 97.0 13.7 42.0 0.86 92.0 92.3 91.5 7.5 2.5 3.2 0.13 K 229
37 200L 1LE0101-2AA54-1.B4 IE 2 2955 120 14.5 50 0.88 92.5 92.8 92.3 7.5 2.5 3.2 0.15 K 245
45 225M 1LE0101-2BA24-1.B4 IE 2 2965 145 17.4 61 0.88 92.9 93.1 92.5 7.9 2.5 3.1 0.24 K 307
55 250M 1LE0101-2CA24-1.B4 IE 2 2970 177 21.5 74 0.88 93.2 93.2 91.8 7.5 2.5 3 0.42 K 378
75 280S 1LE0101-2DA04-1.B4 IE 2 2975 241 31.0 101 0.87 93.8 93.8 92.7 7.5 2.8 3 0.75 K 550
90 280M 1LE0101-2DA24-1.B4 IE 2 2978 289 37.5 121 0.87 94.1 94.1 92.9 7.5 3 3.1 0.88 K 570
110 315S 1LE0101-3AA04-1.B4 IE 2 2982 352 36.0 143 0.90 94.3 94.3 93.3 7.5 2.2 2.6 1.4 J 740
132 315M 1LE0101-3AA24-1.B4 IE 2 2982 423 35.5 170 0.91 94.6 94.6 93.9 7.5 2.3 2.9 1.7 J 855
160 315L 1LE0101-3AA54-1.B4 IE 2 2982 512 39.5 205 0.92 94.8 95.1 94.1 7.5 2.5 2.8 1.9 J 970
185 315L 1LE0101-3AA64-1.B4 IE 2 2982 592 48.5 230 0.92 95.0 95.3 94.2 7.5 2.5 2.8 2.3 J 1080
200 315L 1LE0101-3AA74-1.B4 IE 2 2982 641 48.5 255 0.92 95.0 95.3 94.4 7.5 2.5 2.8 2.3 J 1090
220 355M 1LE0101-3BA24-1.B4 IE 2 2980 705 38.5 280 0.90 95.0 95.0 92.8 7.1 2 2.2 2.9 J 1600
250 355M 1LE0101-3BA34-1.B4 IE 2 2980 801 35.0 320 0.90 95.0 95.0 93.0 7.1 2 2.2 3 J 1650
280 355L 1LE0101-3BA54-1.B4 IE 2 2980 897 42.5 360 0.90 95.0 95.1 93.0 7.1 2 2.2 3.5 J 1830
315 355L 1LE0101-3BA64-1.B4 IE 2 2980 1009 43.5 405 0.90 95.0 95.1 93.1 7.1 2 2.3 3.5 J 1840

Electrical data - 1LE0 - IE2 - 4-pole (IE2 Cast Iron) 1500 rpm 4-pole, 525 VΔ 50 Hz
0.55 80M 1LE0101-0DB24-1..4 - 1425 3.7 0.61 1.01 0.80 74.0 74.7 70.1 6.0 2.0 2.7 0.0021 F 17.5
0.75 80M 1LE0101-0DB34-1..4 IE 2 1440 5.0 0.76 1.38 0.75 79.6 79.6 76.8 6.5 2.8 3.5 0.0027 F 19
1.1 90S 1LE0101-0EB04-1..4 IE 2 1440 7.3 1.22 1.99 0.75 81.4 81.4 77.6 7.0 2.8 3.5 0.0041 G 24
1.5 90L 1LE0101-0EB44-1..4 IE 2 1440 9.9 1.56 2.60 0.76 82.8 82.8 80.2 7.0 3.0 3.8 0.0047 G 27
2.2 100L 1LE0101-1AB44-1..4 IE 2 1435 14.6 1.99 3.60 0.79 84.3 85.0 83.1 7.0 3.0 3.2 0.0081 F 33
3 100L 1LE0101-1AB54-1..4 IE 2 1435 20.0 2.70 4.85 0.79 85.5 86.3 84.2 7.0 3.0 3.2 0.010 F 37
4 112M 1LE0101-1BB24-1..4 IE 2 1445 26.4 3.40 6.4 0.79 86.6 87.1 85.8 7.1 2.7 3.1 0.011 L 45
5.5 132S 1LE0101-1CB04-1.B4 IE 2 1460 36.0 4.65 8.8 0.79 87.7 88.2 86.9 7.5 2.5 3.1 0.021 L 61
7.5 132M 1LE0101-1CB24-1.B4 IE 2 1460 49.1 5.1 11.4 0.82 88.7 89.4 88.8 7.7 2.7 3.2 0.029 L 73
11 160M 1LE0101-1DB24-1.B4 IE 2 1465 71.7 5.1 15.9 0.84 89.8 90.4 90.1 7.5 2.5 3.1 0.051 K 103
15 160L 1LE0101-1DB44-1.B4 IE 2 1465 97.8 9.0 21.5 0.85 90.6 91.3 90.6 7.8 2.7 3.2 0.066 K 130
18.5 180M 1LE0101-1EB24-1.B4 IE 2 1465 121 9.3 26.5 0.85 91.2 91.8 91.8 7.3 2.5 3.2 0.13 K 165
22 180L 1LE0101-1EB44-1.B4 IE 2 1465 143 11.7 31.0 0.85 91.6 92.3 92.7 7.3 2.4 3.2 0.14 K 180
30 200L 1LE0101-2AB44-1.B4 IE 2 1470 195 14.5 42.0 0.85 92.3 92.9 92.9 7.3 2.7 3.2 0.22 K 238
37 225S 1LE0101-2BB04-1.B4 IE 2 1475 240 17.4 51 0.86 92.7 93.2 92.9 7.3 2.7 3.2 0.45 K 298

28 Chapter 2 · Motor selection


© Siemens AG 2014

SIMOTICS General Purpose (Cast Iron) – IE2


Cast Iron Series
Efficiency class IE1 IE2
Series 1LE0102 1LE0101
No. of poles 2 4 6 2 4 6
Cooling Self-ventilated (IC 411) Self-ventilated (IC 411)
Degree of protection IP55 IP55
Insulation Thermal class 155(F) Thermal class 155(F)
Utilization Thermal class 130(B) Thermal class 130(B)
Frame size 80 ... 355 80 ... 355
Rated output at 50 Hz 0.55 ... 315 kW 0.55 ... 315 kW
Rated torque at 50 Hz 2.6 ... 2414 Nm 2.6 ... 2412 Nm

Electrical data - 1LE0 - IE2 - 4-pole (IE2 Cast Iron) 1500 rpm 4-pole, 525 VΔ 50 Hz
Rated Frame Article IE Rated No Rated Rated Efficiency at Starting Break- Moment Torque Net
output size number class speed torque load current power 100% 75% 50% cur- torque down of class weight
current factor load load load rent torque inertia (IMB3)
kW rpm Nm A A % % % Nm kgm² kg
45 225M 1LE0101-2BB24-1.B4 IE 2 1475 291 19.9 61 0.87 93.1 93.5 93.9 7.3 2.7 3.2 0.51 K 322
55 250M 1LE0101-2CB24-1.B4 IE 2 1480 355 24.5 75 0.86 93.5 93.9 93.3 7.5 3.1 3.5 0.8 K 410
75 280S 1LE0101-2DB04-1.B4 IE 2 1485 482 34.5 101 0.87 94.0 94.3 93.9 7.5 2.7 3.1 1.4 K 555
90 280M 1LE0101-2DB24-1.B4 IE 2 1485 579 43.5 121 0.87 94.2 94.3 94.2 7.5 2.7 3.1 1.5 K 610
110 315S 1LE0101-3AB04-1.B4 IE 2 1488 706 51 148 0.86 94.5 94.5 93.9 7.3 2.8 2.9 2.2 K 750
132 315M 1LE0101-3AB24-1.B4 IE 2 1486 848 42.5 174 0.88 94.7 94.7 95.0 7.3 2.5 2.7 2.5 J 875
160 315L 1LE0101-3AB54-1.B4 IE 2 1488 1027 59 210 0.88 94.9 94.9 95.1 7.4 3.0 2.9 3.0 J 960
185 315L 1LE0101-3AB64-1.B4 IE 2 1488 1187 66 240 0.88 95.1 95.1 95.0 7.4 3.0 3.0 3.6 J 1070
200 315L 1LE0101-3AB74-1.B4 IE 2 1488 1284 66 265 0.88 95.1 95.1 95.1 7.4 3.0 3.0 3.7 J 1080
220 355M 1LE0101-3BB24-1.B4 IE 2 1490 1410 53 280 0.90 95.1 95.2 93.3 6.9 2.0 2.2 6.6 J 1640
250 355M 1LE0101-3BB34-1.B4 IE 2 1490 1602 46.5 320 0.90 95.1 95.2 93.8 6.9 2.0 2.2 6.9 J 1680
280 355L 1LE0101-3BB54-1.B4 IE 2 1490 1795 50 360 0.90 95.1 95.2 93.8 6.9 2.0 2.2 7.7 J 1830
315 355L 1LE0101-3BB64-1.B4 IE 2 1490 2019 57 405 0.90 95.1 95.2 93.8 6.9 2.0 2.2 8.5 J 1900

Electrical data - 1LE0 - IE2 - 6-pole (IE2 Cast Iron) 1000 rpm 6-pole, 525 VΔ 50 Hz
0.55 80M 1LE0101-0DC34-1..4 - 895 5.9 0.83 1.12 0.76 71.0 72.0 68.5 3.8 2.1 2.4 0.0028 C 18.5
0.75 90S 1LE0101-0EC04-1..4 IE 2 935 7.7 0.97 1.52 0.71 75.9 76.5 72.7 3.9 2.0 2.5 0.0038 C 26
1.1 90L 1LE0101-0EC44-1..4 IE 2 945 11.1 1.52 2.15 0.71 78.1 78.1 75.7 4.4 2.2 2.7 0.0046 D 27
1.5 100L 1LE0101-1AC44-1..4 IE 2 945 15.2 1.81 2.80 0.74 79.8 80.1 78.2 4.6 2.1 2.6 0.0086 D 34
2.2 112M 1LE0101-1BC24-1..4 IE 2 950 22.1 2.20 4.05 0.73 81.8 82.5 81.0 5.2 2.4 3.0 0.012 E 44
3 132S 1LE0101-1CC04-1..4 IE 2 960 29.8 2.80 5.4 0.73 83.3 84.3 83.4 5.2 2.0 2.8 0.019 D 56
4 132M 1LE0101-1CC24-1..4 IE 2 960 39.8 3.85 7.1 0.73 84.6 85.4 84.5 5.6 2.1 2.9 0.024 K 66
5.5 132M 1LE0101-1CC34-1.B4 IE 2 960 54.7 5.2 9.4 0.75 86.0 86.6 85.7 6.0 2.3 3.2 0.031 K 75
7.5 160M 1LE0101-1DC24-1.B4 IE 2 965 74.2 6.0 12.3 0.77 87.2 87.9 87.2 5.8 2.0 2.9 0.056 J 104
11 160L 1LE0101-1DC44-1.B4 IE 2 965 109 8.2 17.4 0.78 88.7 89.4 89.5 6.6 2.2 3.1 0.077 K 132
15 180L 1LE0101-1EC44-1.B4 IE 2 975 147 11.3 23.5 0.78 89.7 90.4 89.9 6.5 2.3 3.0 0.18 K 170
18.5 200L 1LE0101-2AC44-1.B4 IE 2 975 181 10.5 28.0 0.81 90.4 91.0 91.8 5.8 2.2 2.8 0.27 J 220
22 200L 1LE0101-2AC54-1.B4 IE 2 975 215 12.5 32.5 0.82 90.9 91.4 91.9 6.5 2.3 2.8 0.32 J 240
30 225M 1LE0101-2BC24-1.B4 IE 2 980 292 14.8 43.5 0.83 91.7 92.3 92.7 6.7 2.4 2.8 0.62 J 294
37 250M 1LE0101-2CC24-1.B4 IE 2 982 360 17.4 53 0.83 92.2 92.8 92.3 7.5 3.0 2.8 0.91 K 394
45 280S 1LE0101-2DC04-1.B4 IE 2 985 436 21.5 63 0.85 92.7 93.3 93.5 7.1 2.5 2.8 1.2 K 510
55 280M 1LE0101-2DC24-1.B4 IE 2 986 533 26.5 77 0.85 93.1 93.7 93.6 7.5 2.4 2.7 1.5 K 535
75 315S 1LE0101-3AC04-1.B4 IE 2 986 726 40.5 104 0.85 93.7 94.3 93.8 7.5 2.4 3.0 2.3 K 680
90 315M 1LE0101-3AC24-1.B4 IE 2 986 872 39.0 124 0.85 94.0 94.5 94.4 7.0 2.3 2.8 2.8 J 835
110 315L 1LE0101-3AC54-1.B4 IE 2 988 1063 43.5 148 0.86 94.3 94.7 94.6 6.5 2.2 2.7 3.9 J 975
132 315L 1LE0101-3AC64-1.B4 IE 2 988 1276 53 177 0.86 94.6 95.0 94.9 7.8 2.2 2.4 4.3 K 1030
160 355M 1LE0101-3BC24-1.B4 IE 2 990 1543 38.5 215 0.87 94.8 95.1 93.5 6.5 2.0 2.1 7.7 J 1650
185 355M 1LE0101-3BC34-1.B4 IE 2 990 1785 43.5 245 0.87 95.0 95.3 93.5 6.5 2.0 2.1 8.4 J 1690
200 355M 1LE0101-3BC44-1.B4 IE 2 990 1929 42.5 270 0.87 95.0 95.3 93.6 6.5 2.0 2.1 9.1 J 1730
220 355L 1LE0101-3BC54-1.B4 IE 2 990 2122 48.5 295 0.87 95.0 95.3 93.5 6.5 2.0 2.1 10.1 J 1850
250 355L 1LE0101-3BC64-1.B4 IE 2 990 2412 56 335 0.87 95.0 95.3 93.5 6.5 2.0 2.1 11.4 J 1930

Chapter 2 · Motor selection 29


© Siemens AG 2014

Distribution Motor Options


Aluminum Series
SIMOTICS GP 1LA7 Standard Efficiency IE1 1 available available
SIMOTICS GP 1LE10 Standard Efficiency IE1 2
SIMOTICS GP 1LE10 High Efficiency IE2 3 available
Cast Iron
SIMOTICS GP 1LE0102 Standard Efficiency IE1 4 available
SIMOTICS GP 1LE0101 High Efficiency IE2 5 available

Series
63 71 80 90 100
Option Description Motor Order Code Availability
Voltage and frequency
1LE....-....2-2... 2,3,4,5
230 V/400 VY, 50 Hz     
1LA7...-...1. 1
400 V/690 VY, 50 Hz 1LE....-....3-4… 2,3,4,5 – – – – 
1LE....-....2-1... 2,3,4,5
220 V/380 VY, 50 Hz     
1LA7...-...9. L1R 1
380 V660 VY, 50 Hz 1LE010.-....3-3… 2,3,4,5 – – – – 
1LE010.-....2-3... 2,3,4,5
415 VY, 50 Hz     
1LA7...-...9. L1C 1
415 V, 50 Hz 1LE010.-....3-5… 2,3,4,5 – – – – 
1LE010.-....4-1... 2,3,4,5
525 V, 50 Hz     
1LA7...-...9. L1Y 1
Type of construction
1LE....-.....-.A.. 2,3,4,5
IM B3     
1LA7...-....0 1
1LE....-.....-.J.. 2,3,4,5
IM B35     
1LA7...-....6 1
1LE....-.....-.F.. 2,3,4,5
IM B5     
1LA7...-....1 1
1LE....-.....-.G.. 2,3,4,5
IM V1 (a)     
1LA7...-....1 1
1LE....-.....-.K.. 2,3,4,5
IM B14     
1LA7...-....2 1
Mechanical design and degrees of protection
1LE....-.....-....-Z H03 2,3,4,5
Condensation drain holes ‘ ‘ ‘ ‘ ‘
1LA7...-.....-Z L12 1
Drive-end seal for flange-mounting motors, 1LE....-.....-....-Z H23 2,3
    
oil-tight to 0.1 bar 1LA7...-.....-Z K17 1
 2, 3
Prepared for mountings, center hole only 1LE....-.....-....-Z G40 2,3,5 – – 5 5
5
Heating and ventilation
1LE....-.....-....-Z Q02 2,3,4,5
Anti-condensation heating for 230 V     
1LA7...-.....-Z K45 1
1LE....-.....-....-Z Q03 2,3,4,5
Anti-condensation heating for 115 V     
1LA7...-.....-Z K46 1
1LE1...-.....-....-Z F74 2, 3
 1, 4, 5  1, 4, 5  2, 3
Sheet metal fan cover 1LE0...-.....-.... 4, 5  
3 3  4, 5
1LA7...-..... 1
Motor protection
1LE….-.....-..A. 2,3,4,5
Without protection     
1LA7...-..... 1
Motor protection with PTC thermistor
with 1 or 3 embedded temperature sensors 1LE….-.....-..B. 2,3,4,5
    
for tripping (d) 1LA7...-.....-Z A11 1

Bearing and lubrication


Bearing design
1LE….-.....-....-Z L22 2,3,4,5 – – – – 
for increased cantilever forces
Regreasing device 1LE....-.....-....-Z L23 2,3,4,5 – – – – 
Packing, safety notes, documentation and certificate
1LE1...-.....-....-Z B07 2,3  1, 3  1, 3  2, 3
Extra rating plate for voltage tolerance (e) 1LE0...-.....-.... 4,5  
 4, 5  4, 5  4, 5
1LA7...-.....-Z B07 1
Acceptance test certificate 3.1 1LE....-.....-....-Z B02 2,3,4,5
    
in accordance with EN 10204 (routine test) 1LA7...-.....-Z B02 1
 Standard
 Option in distribution portfolio
‘ Not available in distribution portfolio,only from standard catalog
– Not available
(a) For canopy as modification, please see chapter 5
(b) Standard for 4-pole and 6-pole motor, optional for 2-pole motor

30 Chapter 2 · Motor selection


© Siemens AG 2014

TIP
The most common features are already embedded in our distribution motors, such as metal fan cover, 3 x PTC, etc.
In addition you can also enjoy an exclusive package price on 1LE0.
When you place the order, you simply add these standard features in the article number according to the option
guideline below. Our 1LE0 series already include all embedded features in the basic article number.

available
available

available available available


available available available

112 132 160 180 200 225 250 280 315 355

  – – – – – – – –
         
  – – – – – – – –
         
  – – – – – – – –
         
         

         

         

         –

         

   – – – – – – –

‘ 2, 3 ‘ 2, 3 ‘ 2, 3
      
 4, 5  4, 5  4, 5
   – – – – – – –
 2, 3  2, 3  2, 3
5 5 5 5 5 5 5
5 5 5

         

         

 2, 3  2, 3  2, 3
      
 4, 5  4, 5  4, 5

 2, 3, 4  2, 3, 4 4 4 4 4 4 4 4

–5 –5 –5 –5 –5 –5 –5 –5 –5

 2, 3, 4  2, 3, 4 4 4 4 4 4 4 4

5 5 5 5 5 5 5 5 5

 2, 3, 4  2, 3, 4  2, 3, 4
    (c)  (c)  (c)  (c)
 5 (b)  5 (b)  5 (b)
         

 2, 3  2, 3  2, 3
      
 4, 5  4, 5  4, 5

         
(c) Not available for construction type IM V1
(d) For 1LE10 motors, frame sizes 80 and 90, there is only 1 embedded PTC
(e) Option B07 is standard for 400 V version only

Chapter 2 · Motor selection 31


© Siemens AG 2014

Did you know ? Did you know ?


Power Speed
Power is the work performed in a unit of time, The synchronous speed ns (rpm) of a three-
measured in W (Watt). phase induction motor is obtained from the line
frequency f and the pole pair number p
Dimensions: (4-pole  2p = 4).
120 · f
1W = J/s (1 Joule per second) ns =
2·p
= 1 Nm/s (1 Newton meter per second)
= 1 kgm2/s3 When connected to a 50 Hz line supply, a 2p =
= 0.102 kpm/s 4-pole motor has a synchronous speed of
1 kW = 1.36 HP
120 · 50
= 1500 rpm
4
The following applies to three-phase motors:
The synchronous speeds of the generally used 2, 4,
PN = √3 · Vsupply · Isupply ·  · cos and 6-pole motors are correspondingly obtained
• at a line frequency of 50 Hz
PN Rated power in W 3000, 1500, 1000 rpm
V Rated voltage in V • at a line frequency of 60 Hz
I Line current in A 3600, 1800, 1200 rpm
 Efficiency
cos Power factor The rotor of a three-phase induction motor rotates
with a lower speed (with slip) than the rotating
The rated power is one of the most important field.
parameters of a motor. According to DIN 42673
– and maintaining the regulations according to Slip s is calculated according to the following
VDE 0530 – the individual motor frame sizes are formula:
assigned specific power ratings for continuous s Slip as a %
duty S1. Different operating conditions or different n -n ns Synchronous speed in rpm
s = s · 100
duty types generally result in a change in the rated ns n Rotor speed in rpm
power.
The rated slip sN is correspondingly calculated.
The rotor losses of the motor are approximately
proportional to the slip. The objective is to achieve
a low rated slip in order to achieve a good effi-

Did you know ? ciency.


The rated slip depends on the motor size.
For instance, for small motors, it is approx. 10 %
and for large motors, approx. 1 %.
Torque
Torque is generated by the effect of force applied to
a lever arm. This is the product of force multiplied
by the vertical distance from the axis of rotation;
for belt drives, e.g. circumferential force multiplied
by the radius of the belt pulley.

M Torque in Nm
1000
M = 9.55 · P · P Power in kW
n
n Speed in rpm

32 Chapter 2 · Motor selection


© Siemens AG 2014

Notes

Chapter 2 · Motor selection 33


© Siemens AG 2014

Special features detail


Efficiency
Efficiency classes and efficiencies according to Measuring method according to IEC 60034-2-1:2007
IEC 60034-30:2008 for determining the efficiency
Harmonization of the efficiency classes With the measuring method, the supplementary losses are
no longer applied as a percentage, but instead they are
Different energy efficiency standards exist worldwide for
determined with measurements (IEC 60034-2-1: 2007).
induction motors. To promote international harmonization,
The nominal efficiencies are therefore reduced from EFF1
the international standard IEC 60034-30:2008 (Rotating
to IE2 and from EFF2 to IE1, even though there have been
electrical machines – Part 30: Efficiency classes of single-
no technical or physical changes to the motors.
speed, three-phase, cage-induction motors (IE code)) was
created. This groups low-voltage asynchronous motors Previously: PLL = 0.5 % of P added
into new efficiency classes (valid since October 2008). Now: PLL = Individual measurement
The efficiencies of IEC 60034-30:2008 are based on losses PLL = Load-dependent supplementary losses
determined in accordance with the IEC 60034-2-1:2007
standard. This has been valid since November 2007 and 100
has been replacing the standard IEC 60034-2:1996 since %
November 2010. The supplementary losses are now
Efficiency

90
measured and no longer added as a percentage.

G_D081_EN_00336
IE efficiency classes 80
Classification
The efficiency classes are grouped according to the follow-
acc. to IEC 60034-30:2008
ing nomenclature (IE = International Efficiency): 70
0.75 1.5 3 5.5 11 18.5 30 45 75 110 200 kW
• IE1 (Standard Efficiency)
1.1 2.5 4 7.5 15 20 37 55 90 132 375 kW
• IE2 (High Efficiency) Output
• IE3 (Premium Efficiency)
• IE4 (Super Premium Efficiency) IE1 to IE3 efficiencies 4-pole 50 Hz

The following table shows examples of the efficiency val-


High
Super Premium
Efficiency *
ues according to the current and previous loss calculating
efficiency NEMA Premium Efficient methods.
G_D081_EN_00335

EISA 2007
Premium Efficiency since 12/2010 EFF measuring Losses Losses
NEMA Energy Efficient method (incl. per- determined determined
EISA 2007 centage losses) according to according to
High Efficiency since 12/2010 EN/IEC 60034-2: IEC 60034-2-1: IEC 60034-2-1:
1996 2007 2007
50 Hz 50 Hz 60 Hz
Standard Efficiency
5.5 kW 4-pole 89.2 % 87.7 % 89.5 %
Low IEC motors NEMA motors
efficiency * defined in IEC/TS 60034-31 45 kW 4-pole 93.9 % 93.1 % 93.6 %
110 kW 4-pole Not defined 94.5 % 95.0 %
IE efficiency classes in accordance with the output

Background information

TIP Comprehensive laws have been introduced in the European


Union with the objective of reducing energy consumption
We comply with the latest efficiency standards and and therefore CO2 emissions. EU Directive 640/2009 con-
describe motors for both the IE1 and IE2 efficiencies. cerns the energy consumption or efficiency of induction
Although Siemens also has ranges for IE3 and specific so- motors in the industrial environment. This Directive is now
lutions for IE4 efficiency, these are still considered special- in force in every country of the European economic area.
ized and are not described in this document. In addition
For further details on internationally applicable standards
to these general IE1 and IE2 solutions, Siemens can also
and legal requirements, visit:
provide specific variants for specific markets i.e. in India,
www.siemens.com/international-efficiency
Korea, China etc. In such instances please consult your lo-
cal Siemens representative. www.siemens.com/energysaving
www.siemens.com/sinasave

34 Chapter 3 · Special features detail


© Siemens AG 2014

Did you know ?


The better the efficiency of a motor,
the lower the internal heat loss.
The lower the heat loss, the lower the
temperature rise.
Higher efficiency IE2 motors run cooler than
same size IE1 motors. That increases the
electrical life expectancy of an IE2 motor.
The most important changes at a glance:

CEMEP EU Directive No. 640/2009


voluntary EU agreement adopted on July 22, 2009
based on the IEC 60034-30 standard
Voluntary agreement between the EU commission The EU Directive is in force in every country of the EU.
and the European sector committee of Losses are determined and therefore the efficiency is
Description manufacturers of electrical machines (CEMEP) determined in accordance with IEC 60034-2-1:2007
Number of poles 2, 4 2, 4, 6
Power range 1.1 … 90 kW 0.75 … 375 kW
Level EFF3 – Standard – EFF3 IE1 – Standard Efficiency
EFF2 – Enhanced efficiency IE2 – High Efficiency
EFF1 – Highly efficient IE3 – Premium Efficiency
Voltage 400 V, 50 Hz < 1000 V, 50/60 Hz
Degree of protection IP5X All
Motors equipped with a brake NO In agreement
Geared motors NO YES
Ex motors NO EU Directive – NO
IEC 60034-30 – YES
(but explosion protection always has a higher priority)
Validity Voluntary agreement; will be replaced on IEC 60034-30 standard, valid since October 2008;
implementation the EU Directive will come into force on June 16, 2011.
This means that as of this date, manufacturers are no
longer permitted to place IE1 motors on the market in
the European economic area.

Exceptions to the EU Directive The changes are applicable starting the following dates:
 Motors that are designed to be operated totally sub- June 16, 2011:
merged in a liquid; Compliance with the legally required minimum efficiency
 Motors fully integrated into a product (e.g. a gear unit, class IE2 for induction motors in S1 operation in accor-
pump, fan or compressor) whose energy efficiency can- dance with EU Directive
not be measured independently of the product;
 Motors that are specially designed for operation under January 1, 2015:
the following conditions: Compliance with the legally required minimum efficiency
– At altitudes greater than 1000 meters above sea level; class IE3 for outputs from 7.5 to 375 kW or, as an alterna-
– At ambient temperatures above 40 °C; tive, IE2 motor plus frequency converter
– At maximum operating temperatures above 400 °C; January 1, 2017:
– At ambient temperatures below -15 °C (any motor) Compliance with the legally required minimum efficiency
– With cooling liquid temperatures at the product intake class IE3 for outputs from 0.75 to 375 kW or, as an alterna-
of below 5 °C or above 25 °C; tive, IE2 motor plus frequency converter
– In hazardous areas in the context of Directive 94/9/EC
of the European Parliament and Council;
 Brake motors
The following motors are not involved:
• 8-pole motors
• Pole-changing motors
• Synchronous motors
• Motors for intermittend duty S2 to S9
• Single-phase motors
• Motors specially developed for converter-fed operation
in accordance with IEC 60034-25

Chapter 3 · Special features detail 35


© Siemens AG 2014

Solids, first digit


IP rating The first digit indicates the level of protection that the
The IP Code (or Ingress Protection Rating, sometimes also enclosure provides against access to hazardous parts
interpreted as International Protection Rating) consists (e.g., electrical conductors, moving parts) and the ingress
of the letters IP followed by two digits or one digit and of solid foreign objects.
one letter and an optional letter. As defined in interna- Level Object size Effective against
tional standard IEC 60529, IP Code classifies and rates protected against
the degrees of protection provided against the intrusion – No protection against contact and ingress
of solid objects, dust, accidental contact, and water in 0
of objects
mechanical casings and with electrical enclosures. >50 mm Any large surface of the body, such as the
1 back of a hand, but no protection against
IP 5 5 deliberate contact with a body part
Code number indicating protection against water 2 >12.5 mm Fingers or similar objects
Code number indicating touch protection and 3 >2.5 mm Tools, thick wires, etc.
protection against foreign bodies
4 >1 mm Most wires, screws, etc.
International Protection
Dust protected Ingress of dust is not entirely prevented,
but it must not enter in sufficient quantity
5 to interfere with the satisfactory operation

TIP of the equipment; complete protection


against contact

Some manufacturers offer sealing and protection Dust tight No ingress of dust; complete protection
6
against contact
above IP55. Although it is avialble as an option,
Siemens prefers a true IP55 as a default standard.
• IP55 covers the vast majority of applications as it
offers dust and rain protection
• The IP55 is stable over the life of the motor.
TIP
Higher protections can need maintenance or an A suitable degree of protection should be selected
exact assembly to ensure that the higher proetc- depending on the operating and environmental
tion is real and not just on paper. conditions. Siemens offers a standard which is
• Modifications can be made on an IP55 motor whilst most suitable and applicable over the lifetime of a
maintaining that degree of protection. motor such as true IP55 standard.

Liquids, second digit


Protection of the equipment inside the enclosure against harmful ingress of water.
Level Protected against Testing for Details
0 Not protected – –
Dripping water Dripping water (vertically falling drops) shall have no harmful effect. Test duration: 10 minutes
1
Water equivalent to 1 mm rainfall per minute
Dripping water when Vertically dripping water shall have no harmful effect when the enclosure Test duration: 10 minutes
2
tilted up to 15° is tilted at an angle up to 15° from its normal position. Water equivalent to 3 mm rainfall per minute
Spraying water Water falling as a spray at any angle up to 60° from the vertical shall Test duration: 5 minutes
3 have no harmful effect. Water volume: 0.7 liters per minute
Pressure: 80–100 kN/m²
Splashing water Water splashing against the enclosure from any direction shall Test duration: 5 minutes
4 have no harmful effect. Water volume: 10 liters per minute
Pressure: 80–100 kN/m²
Water jets Water projected by a nozzle (6.3 mm) against enclosure from any Test duration: at least 3 minutes
5 direction shall have no harmful effects. Water volume: 12.5 liters per minute
Pressure: 30 kN/m² at distance of 3 m
Powerful water jets Water projected in powerful jets (12.5 mm nozzle) against the enclosure Test duration: at least 3 minutes
6 from any direction shall have no harmful effects. Water volume: 100 liters per minute
Pressure: 100 kN/m² at distance of 3 m
Immersion up to 1 m Ingress of water in harmful quantity shall not be possible when the Test duration: 30 minutes
7 enclosure is immersed in water under defined conditions of pressure Immersion at depth of 1 m
and time (up to 1 m of submersion).
Immersion beyond The equipment is suitable for continuous immersion in water under Test duration: continuous immersion in water
1m conditions which shall be specified by the manufacturer. Normally, this Depth specified by manufacturer
8 will mean that the equipment is hermetically sealed. However, with
certain types of equipment, it can mean that water can enter but only in
such a manner that it produces no harmful effects.

36 Chapter 3 · Special features detail


© Siemens AG 2014

Thermal class
The Siemens motors are rated at normal sinusoidal voltage The more efficient the motor, the less heat it produces – to
with a class B (130 °C) temperature rise. The windings are the extent that modern motors often only run with internal
rated to class F (155 °C) thus allowing for reserve for the temperatures of 95 °C – much cooler than the limits set by
additional losses associated with variable speed drive the standards.
operation and/or higher ambient temperature and/or over-
load conditions. Siemens uses double coated wires with DURIGNIT
insulation materials and capable varnishes – we consider
The temperature rise of the winding of the motor is all components including electrical connections and
important. It provides a great insight into the design of the bearing grease – our motors are true class F under all
motor and its life expectancy. The cooler a motor runs the circumstances – with reserve built in on top.
better its life expectancy and longer its life. Siemens builds
motors to a minimum of Class F (155 °C) on all material – A claim to class H could be made but that would not reflect
continuous operation for a very long life expectancy. the true life expectancy which you would expect.
• Class B (130 °C) is the normal utilization – even better.
• Class H (180 °C) is reserved for special application
motors.
• Class H motors are considered detrimental for normal
use due to the degradation of the overall life expectancy
of paint and bearings.
• At class H the outside surface temperature can exceed
an unsafe 100 °C.

180 °C

155 °C

Hot-Spot 130 °C
reserve

Typical winding 125 °C


operating 105 °C
temperature Temp. Rise 80 °C
on a higher
efficiency motor

Ambient 40 °C 40 °C 40 °C TIP
Siemens builds
Class B Class F Class H motors with reserve:
The motors are
capable to operate
at least at 155 °C
(Class F) but we only

Did you know ? rate at a nonimal


130 °C (Class B).
• An IE1 motor
can be operated
Although Siemens uses class H wire, we do not rate at 10% overload or
our motors for class H operation. The electrical life at 50 °C ambient
expectancy at class F is four times greater than at temperature.
class H. If used at class B or cooler 400.000 hours • An IE2 motor
and more are not exceptional. can be operated
at 15% overload or
High efficiency motors in IE2 do not generate the at 55 °C ambient
amount of heat to reach thermal class H. temperature.

Chapter 3 · Special features detail 37


© Siemens AG 2014

Derating
Environmental For higher coolant temperatures and / or site altitudes
 Degree of motor protection IP55 higher than 1000 m above sea level, the specified motor
(IEC 60034-5). must be reduced by using the factor kHT. This results in an
admissible output (Padm) of the motor:
 Altitude shall not exceed 1000 m above sea-level
(IEC 60034-1).
 Allowed air temperature between -20 °C and 40 °C Padm = Prated · kHT
(IEC 60034-1).
 Permitted relative humidity:
– -20 °C w T w 20 °C: 100 %
– 20 °C < T w 30 °C: 95 %
– 30 °C < T w 40 °C: 55 %

Reduction factor kHT for different site altitudes and / or coolant temperature
Site altitude above sea level Ambient temperature/coolant temperature
m < 30 ºC 30 ~ 40 ºC 45 ºC 50 ºC 55 ºC 60 ºC

1000 1.07 1.00 0.96 0.92 0.87 0.82


1500 1.04 0.97 0.93 0.89 0.84 0.79
2000 1.00 0.94 0.90 0.86 0.82 0.77
2500 0.96 0.90 0.86 0.83 0.78 0.74
3000 0.92 0.86 0.82 0.79 0.75 0.70
3500 0.88 0.82 0.79 0.75 0.71 0.67
4000 0.82 0.77 0.74 0.71 0.67 0.63

Note:
If operating conditions exceed above values,
please contact our local sales office for the selection of catalog motors.

38 Chapter 3 · Special features detail


© Siemens AG 2014

Anti-condensation
Moisture is present in the air around us. Under the correct Smaller motors are less susceptible than larger motors
circumstances it can condensate. The warmer the air the due to the smaller volume of moist air possible in the mo-
higher the possible moisture content. As air cools the tor. Dew moisture condenses and accumulates in a motor,
moisture carrying content reduces to the point when the which is seen as water collection. The water accumulates
moisture condenses – called the “Dew-Point”. at the lowest point of the motor. It often does no harm as
This condition can be met several times a day under long as the collection point is below the level of the electri-
normal operation, as a motor operates and cools at differ- cal system.
ing times of the day.
Two points that need to be paid attention to are, first, how
much water there is in the air and when it will condensate.
The second is, whether it will do any harm.

Relative humidity Temperature


20 °C 30 °C 40 °C 50 °C 60 °C 70 °C 80 °C 90 °C

10% 2 3 5 8 13 20 29 42
15% 3 5 8 12 19 30 44 63
20% 3 6 10 17 26 39 58 84
25% 4 8 13 21 32 49 73 105
30% 5 9 15 25 39 59 87 126
35% 6 11 18 29 45 69 102 146
40% 7 12 20 33 52 79 116 167
45% 8 14 23 37 58 89 131 188
50% 9 15 26 41 65 98 145 209
55% 10 17 28 46 71 108 160 230
60% 10 19 31 50 78 118 174 251
65% 11 20 33 54 84 128 189 272
70% 12 21 36 58 91 138 203 293
75% 13 23 38 62 97 148 218 314
80% 14 24 41 66 104 157 233 335
85% 15 26 43 70 110 167 247 356
90% 16 27 46 74 117 177 262 377
95% 16 29 49 79 123 187 276 398
100% 17 30 51 83 130 197 291 419

If operating conditions exceed temperatures of 60 °C, For orange colored fields a drain hole is recommended and
please contact our local sales office for the selection of for more important motors a heating is also recommended
catalog motors. (separate space heater of winding heating).

Table showing the weight of moisture contained in the air,


given as g/m³.
TIP
The local temperature is on the x axis and the local relative
humidity is shown on the Y axis. In humid climates, during motor cool down the
air inside contracts, pulling in fresh, warm, humid
Blue fields show normal conditions. air. This humidity condensates inside the motor,
Yellow fields show higher moisture – for motors FS ≥112 forming water droplets. Those water droplets have
a drain hole is recommended. to drain.
Therefore on many motors, especially the larger
ones, Siemens has foreseen drain holes as standard.

Chapter 3 · Special features detail 39


© Siemens AG 2014

Anti-condensation
Anti-condensation heating can be provided for motors
where there is a danger that moisture condensation will G_D081_EN_00348

form on the winding due to the climatic situation. This 80 80


anti-condensation heater warms up the air in the motor to [°C]

Dew-Point Temperature [°C]


70 70
a temperature above the dew point temperature in order
65
to prevent condensation forming inside the motor. 60 60
The anti-condensation heating must not be switched on 55
while the motor is operational. 50 50
45
Graphic showing the temperature at which the moisture in 40 40
35
the air will condensate to water. The lines on the left show
30 30
the local temperature. The x-axis gives the local relative 50 55 60 65 70 75 80 85 90 95
humidity. The “dew Point” temperature can be read on the Relative Humidity [%]
Y-axis.

TIP
Another possible solution is to connect a voltage
to the stator terminals U1 and V1 that should be

G_D081_XX_00349
between 4 and 10% of the rated motor voltage.
Approximately 20 to 30% of the rated current is
sufficient in order to achieve an adequate tempera-
ture rise to avoid condensation.

Drain hole location

Motor protection
PTC thermistor temperature sensors are predominantly
used for thermistor motor protection devices (alarm or 4.5

G_D081_EN_00350
shutdown) for motors. These thermistors are generally 4
Resistance [kΩ]

integrated in the winding overhang. As a consequence, 3.5


the stator winding is directly protected. The temperature 3
difference between alarm and shutdown (trip) is 10 K. 2.5
2
1.5
When a limit temperature is reached (nominal tripping 1
temperature), the resistance of PTC thermistors will have a PTC
0.5
step change. This is evaluated by a tripping unit and can be 0
-50 0 50 100 150 200
sued to open auxiliary circuits.
Temperature [°C]

Thermal protection with PTC thermistors with 3 embed-


Note:
ded temperature sensors for tripping is provided in our IE2
motors above frame size 112 as standard version. Anyhow The PTC thermistors themselves cannot be subjected to
it can be selected as an option for our IE1 motors and IE2 high currents and voltages. This would result in destruc-
motors with frame size less than 132. Connection can be tion of the semiconductor. The switching hysteresis of the
done through 2 auxiliary terminals in the terminal box. PTC thermistor and tripping unit is low, which supports fast
restarting of the drive. Motors with this type of protection
are recommended for heavy duty starting, switching duty,
TIP extreme changes in load, high ambient temperatures or
fluctuating supply systems.
3 x PTC have already been
embedded in our 1LE0 IE2
motors as standard version.

40 Chapter 3 · Special features detail


© Siemens AG 2014

Converter-fed application
The insulation system of our motors is capable for At operating speeds above rated speed the noise and
converter-fed operation as standard. vibration levels increase and the bearing lifetime reduces.
For sinusoidal (mains) supplies 690 Vrms 50 Hz with: Attention should be paid to the re-greasing intervals and
phase to phase 1200 Vrms capability the grease service life. For converter-fed operation with
phase to ground 900 Vrms capability frequencies greater than 60 Hz special balancing is re-
For converter-fed operation, as standard: quired for compliance with the specified limit values.
460 Vrms max. Frequency limited by motor maximum
Voltage (peak and gradient) withstand levels
speed 5000 V/s
The dielectric stress of the winding insulation is deter-
mined by:
• the peak voltage, rise time and frequency of the impulses
Converter-fed application
produced by the converter.
Our motors are suitable for pumps, fans, compressors,
• the characteristics and the length of the connection
textile machine and mechanical machine applications
leads between the converter and motor.
where variable or constant speed is required.
• the winding construction and other system parameters,
In applications where the motor is driven by a converter,
especially the voltages between the different parts of
the degree of electrical interference depends on the type
the winding and the ground represent dielectric stress at
of converter used (type, number of IGBTs, interference sup-
the insulation system.
pression measures, and manufacturer), cabling, distance
and application requirements. The installation guidelines The standard insulation of our motors is designed to
of the converter manufacturer with regards to electromag- withstand voltage peak and gradient which is showed in
netic compatibility must be considered at all times during the diagram:
the design and implementation phases.
At rated output with converter-fed operation, the motors 1 600

G_D081_EN_00352
will be used in temperature class 155 (F). To prevent
Impulse voltage ÛLL [V]

1 400
damage as a result of bearing currents, insulated bearings
are recommended to be assembled for frame size 250 and 1 200
above. Please inquire Siemens about the detailed informa-
1 000
tion of insulated bearing.
800
Converter-fed operation 600
The standard insulation of our motors is designed such 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
Rise time t a [μs]
that operation is possible on the converter at mains volt-
age up to 460 V.
u
Our motors are capable for converter-fed operation with
certain characteristics load, of which the load torque char- u(t1) 100 %
acteristics is referred in the following diagram: 90 %

ta
100
G_D081_EN_00415

∆u = (t1) – u(t0)
80 50 %
Rated torque [%]

60
G_D081_XX_00353

40
10 %
20 u(t 0) 0%
0 t0 t1 t
0 50 100 150
Rated frequency [%]
Forced ventilation Motor self ventilation

By usage with admissible torque and below, the motor can


be operated with self cooling; by usage over the admissible
Did you know ?
torque line, the motor with forced ventilation is needed. As the motor gets larger so does the internal surface area be-
tween the stator and rotor. That surface has a stray capacitance

TIP
which can lead to a voltage on the shaft – and that voltage can
lead to bearing failure (bearing currents). The situation is
aggravated by converter-fed operation. Siemens recommends
These motors do not have a special series the use of insulated bearings for motors of frame size ≥250. The
for converter-fed operation – they are suited as insulated bearing as an option can be supplied out of our stan-
standard. On-line or converter-fed operation. dard catalog portfolio D 81.1 and on request for the 1LE0 series.

Chapter 3 · Special features detail 41


© Siemens AG 2014

Converter-fed application
SIMOTICS General Purpose
Aluminum Series Cast Iron Series
Efficiency IE1 Efficiency IE2 Efficiency IE1 Efficiency IE2
Frame Number 1LA7 1LE1002 1LE1001 1LE0102 1LE0101
size of poles
max. me- max. me- max. me- max. me- max. me-
chanical fmax chanical fmax chanical fmax chanical fmax chanical fmax
speed speed speed speed speed
2 6000 100 - - - - - - - -
63 4 4200 140 - - - - - - - -
6 3600 180 - - - - - - - -
2 6000 100 - - - - - - - -
71 4 4200 140 - - - - - - - -
6 3600 180 - - - - - - - -
2 6000 100 - - 6000 100 5200 87 5200 87
80 4 4200 140 - - 4200 140 3600 120 3600 120
6 3600 180 - - 3600 180 2400 120 2400 120
2 6000 100 - - 6000 100 5200 87 5200 87
90 4 4200 140 - - 4200 140 3600 120 3600 120
6 3600 180 - - 3600 180 2400 120 2400 120
2 - - 6000 100 6000 100 5200 87 5200 87
100 4 - - 4200 140 4200 140 3600 120 3600 120
6 - - 3600 180 3600 180 2400 120 2400 120
2 - - 6000 100 6000 100 5200 87 5200 87
112 4 - - 4200 140 4200 140 3600 120 3600 120
6 - - 3600 180 3600 180 2400 120 2400 120
2 - - 5600 93 5600 93 4500 75 4500 75
132 4 - - 4200 140 4200 140 2700 90 2700 90
6 - - 3600 180 3600 180 2400 120 2400 120
2 - - 4800 80 4800 80 4500 75 4500 75
160 4 - - 4200 140 4200 140 2700 90 2700 90
6 - - 3600 180 3600 180 2400 120 2400 120
2 - - - - - - 4500 75 4500 75
180 4 - - - - - - 2700 90 2700 90
6 - - - - - - 2400 120 2400 120
2 - - - - - - 4500 75 4500 75
200 4 - - - - - - 2300 77 2300 77
6 - - - - - - 1800 90 1800 90
2 - - - - - - 3600 60 3600 60
225 4 - - - - - - 2300 77 2300 77
6 - - - - - - 1800 90 1800 90
2 - - - - - - 3600 60 3600 60
250 4 - - - - - - 2300 77 2300 77
6 - - - - - - 1800 90 1800 90
2 - - - - - - 3600 60 3600 60
280 4 - - - - - - 2300 77 2300 77
6 - - - - - - 1800 90 1800 90
2 - - - - - - 3600 60 3600 60
315 4 - - - - - - 2300 77 2300 77
6 - - - - - - 1800 90 1800 90
2 - - - - - - 3600 60 3600 60
355 4 - - - - - - 2300 77 2300 77
6 - - - - - - 1800 90 1800 90

42 Chapter 3 · Special features detail


© Siemens AG 2014

Mechanical stress and grease lifetime


(converter-fed operation).
High speeds that exceed the rated speed and the resulting
increased vibrations alter the mechanical running smooth-
ness and the bearings are subject to increased mechanical
stress. This reduces the grease lifetime and the bearing
lifetime. More detailed information on request.

Ventilation/noise generation (converter-fed operation).


The fan noise can increase at speeds that are higher than
the rated speed of self-ventilated motors. To increase
motor utilization at low speeds it is recommended that
forced ventilated motors are used.

Mechanical limit speeds


When the motor is operated at its rated frequency, it is
important to note that the maximum speeds are limited by
the limits for the roller bearings, critical rotor speed and
rigidity of the rotating parts.

All the data listed in the brochure is applicable for a 50 Hz


line supply. With converter-fed operation, the reduction
factors for constant torque and drives for fans, pumps and
compressors must be observed.

TIP
By use of converter-fed operation, motors can run
at speeds higher than 50 Hz or 60 Hz nominal speed.
High speeds that exceed the rated speed of a motor
can lead to increased vibration and substantially
decrease the life expectancy of the bearings.
The maximum mechanical speed of a motor must
not be exceeded due to risk of failure. More detailed
information on request.

Chapter 3 · Special features detail 43


© Siemens AG 2014

Noise
Motors are often used in applications in which noise is
a primary concern. The use of converters can excite the
surfaces of motors and sound of diverse frequencies can
be resonate in the cooling channels. Aluminum Seri
Siemens has addressed this issue but modifying the core Efficiency IE1
Output
design. 1LA7 1LE1002
(kW)
Surfaces, shapes and materials and air channels have been 3000 rpm 1500 rpm 1000 rpm 3000 rpm 1500 rpm
optimised. The result is a motor which is quieter, especially (2-pole) (4-pole) (6-pole) (2-pole) (4-pole)
with converter-fed operation. 0.09 - - 39 / 50 - -
0.12 - 42 / 53 - - -
0.18 49 / 60 42 / 53 39 / 50 - -
0.25 49 / 60 44 / 55 39 / 50 - -
0.37 52 / 63 44 / 55 40 / 51 - -
0.55 52 / 63 47 / 58 40 / 51 - -
0.75 56 / 67 47 / 58 43 / 55 - -
1.1 56 / 67 48 / 60 43 / 55 - -
1.5 60 / 74 48 / 60 - - -
2.2 60 / 74 - - - 60 / 72
3 - - - 67 / 79 60 / 72
4 - - - 69 / 81 58 / 70
5.5 - - - 68 / 80 64 / 76
7.5 - - - 68 / 80 64 / 76
11 - - - 70 / 82 65 / 77
15 - - - 70 / 82 65 / 77
18.5 - - - 70 / 82 -
22 - - - - -
30 - - - - -
37 - - - - -
45 - - - - -
55 - - - - -
75 - - - - -
90 - - - - -
110 - - - - -
132 - - - - -
160 - - - - -
185 - - - - -
200 - - - - -
220 - - - - -
250 - - - - -
280 - - - - -
315 - - - - -

44 Chapter 3 · Special features detail


© Siemens AG 2014

SIMOTICS General Purpose


Lpfa / LWA ( dB(A) )
ies Cast Iron Series
Efficiency IE2 Efficiency IE1 Efficiency IE2
1LE1001 1LE0102 1LE0101
1000 rpm 3000 rpm 1500 rpm 1000 rpm 3000 rpm 1500 rpm 1000 rpm 3000 rpm 1500 rpm 1000 rpm
(6-pole) (2-pole) (4-pole) (6-pole) (2-pole) (4-pole) (6-pole) (2-pole) (4-pole) (6-pole)
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - 42 / 53 - - - - - -
- - 53 / 64 42 / 53 - 45 / 57 44 / 56 - 45 / 57 44 / 56
- 60 / 71 53 / 64 43 / 55 53 / 65 45 / 57 48 / 60 53 / 65 45 / 57 48 / 60
- 60 / 71 56 / 68 43 / 55 53 / 65 48 / 60 48 / 60 53 / 65 47 / 59 48 / 60
59 / 71 65 / 77 56 / 68 59 / 71 60 / 72 48 / 60 54 / 66 60 / 72 47 / 59 52 / 64
57 / 69 65 / 77 60 / 72 57 / 69 60 / 72 57 / 69 54 / 66 60 / 72 55/ 67 54 / 66
63 / 75 67 / 79 60 / 72 63 / 75 64 / 76 57 / 69 57 / 69 62 / 74 55/ 67 56 / 69
63 / 75 69 / 81 58 / 70 63 / 75 65 / 77 57 / 69 57 / 69 63 / 75 55/ 67 56 / 69
63 / 75 68 / 80 64 / 76 63 / 75 68 / 80 58 / 71 57 / 69 66 / 79 57 / 70 56 / 69
67 / 79 68 / 80 64 / 76 67 / 79 68 / 80 58 / 71 61 / 73 66 / 79 57 / 70 60 / 73
67 / 79 70 / 82 65 / 77 67 / 79 70 / 83 61 / 74 61 / 73 67 / 80 60 / 73 60 / 73
- 70 / 82 65 / 77 - 70 / 83 61 / 74 61 / 74 67 / 80 60 / 73 61 / 74
- 70 / 82 - - 70 / 83 63 / 76 65 / 78 67 / 80 61 / 74 65 / 78
- - - - 72 / 85 63 / 76 65 / 78 69 / 82 61 / 74 65 / 78
- - - - 76 / 90 65 / 78 66 / 80 71 / 84 63 / 76 65 / 79
- - - - 76 / 90 66 / 80 66 / 80 71 / 84 63 / 77 65 / 79
- - - - 76 / 90 66 / 79 66 / 80 74 / 88 63 / 77 65 / 79
- - - - 78 / 92 67 / 81 66 / 80 74 / 88 64 / 78 65 / 79
- - - - 79 / 93 70 / 84 70 / 84 74 / 88 66 / 80 66 / 80
- - - - 79 / 93 70 / 84 70 / 84 76 / 90 66 / 80 66 / 80
- - - - 80 / 94 76 / 90 70 / 84 78 / 92 69 / 83 68 / 82
- - - - 80 / 94 76 / 90 70 / 84 78 / 92 69 / 83 68 / 83
- - - - 80 / 94 78 / 92 77 / 92 81 / 95 69 / 83 72 / 87
- - - - 85 / 98 78 / 92 77 / 92 81 / 95 74 / 88 75 / 90
- - - - 85 / 98 78 / 92 77 / 92 81 / 95 74 / 88 75 / 90
- - - - 86 / 101 86 / 101 77 / 92 86 / 101 82 / 97 75 / 90
- - - - 86 / 101 86 / 101 - 86 / 101 82 / 97 -
- - - - 88 / 103 86 / 101 - 88 / 103 85 / 100 -
- - - - 88 / 103 86 / 101 - 88 / 103 85 / 100 -

In order to define the motor noise level, the A-weighted


sound pressure level (LA) is measured at several points on
the measuring plane (1 m away from the motor surface).
The measurement is carried out in a room with low
reflection. As a result of noise reflection, the level can be
increased up to 3 dB(A) depending on the acoustic proper-
ties of the surroundings.
The A sound power level is normally used when engineer-
ing projects and when it is necessary to determine the
noise radiated from a group of motors whose envelope
dimensions differ significantly.

Chapter 3 · Special features detail 45


© Siemens AG 2014

Bearing
The bearings are especially important in order that the The bearing lifetime of motors with horizontal type
motor runs perfectly. A good selection of bearing will of construction is at least 40,000 hours if there is no
guarantee long lubrication intervals, low noise, additional axial loading at the coupling output and at least
low-vibration operation and longer lifetime as well. 20,000 hours with the maximum admissible loads.
This assumes that the motor is operated at 50 Hz.
There are many types of bearing: diverse ball and cylinder
bearings, taper and specialized bearings. Siemens has A bearing is only as good as its lubrication. Siemens
selected an applicable range of single and double shielded designed a special lithium complex grease – Unirex N3.
bearings. Z for when regreasing is needed and ZZ when It gives a super thermal stability for optimized bearing life.
no-regreasing is wished for. The grease gives a great temperature range from
A selection of C62 for speed and size and C63 for load -30 °C to 130 °C – with an intermittent temperature
carrying capacity associated with belt loads. reserve to 165 °C.
Sealed-for-life bearings are avoided as they bring inherent
disadvantages in operation temperatures and limit Frame size Number of Grease lifetime up to CT 40 ºC 1)
operational speeds. poles
Special bearings are avoided due to their disadvantages Grease for permanent lubrication bearing
outside of their specific application. 80 ... 250 2, 4, 6 20000 or 40000 (h) 2)
Grease for regreasable bearing
100 ... 160 2, 4, 6 8000 (h)
180 ... 250 2 4000 (h)
TIP 180 ... 250 4, 6 8000 (h)
280 ... 315 2 3000 (h)
Factors that reduce the lifetime of a bearing:
280 ... 315 4, 6 5000 (h)
• Operating a motor beyond the rated speed increas-
355 2 2000 (h)
es the motor vibration and results in an additional
355 4, 6 4000 (h)
radial and axial force on the bearing.
1)
• Increased motor vibration due to the environment If the coolant temperature is increased by 10 K, the grease lifetime
or other equipment results in an higher radial and and regreasing interval are halved.
2) 40,000 h apply to horizontally installed motors with coupling
axial force.
output without additional axial loads.

46 Chapter 3 · Special features detail


© Siemens AG 2014

Cantilever force
This force acts transversely at the centerline of the motor
shaft extension. The cantilever force is calculated from the

G_D081_EN_00128a
circumferential force multiplied by the pre-tension fac- FQ
tor, which is dependent on the mechanical transmission
characteristics of the particular belt.

The permissible cantilever forces for the individual motor x


xmax. x0
frame sizes and speeds are specified in Catalog D 81.1.
For motors with deep-groove ball bearings, the permissible
cantilever force can be increased by replacing the bearings
at the drive end with cylindrical roller bearings. Belt drive
A belt drive is used to connect two parallel shafts, the
In order to calculate the admissible cantilever forces for motor shaft with the shaft of the driven machine, whereby
a radial load, the line of force (i.e. the centerline of the the speed can be simultaneously changed corresponding
pulley) of the cantilever force FQ(N) must lie within the to the ratio between the two belt pulley diameters.
free shaft extension (dimension x).
Dimension x [mm] is the distance between the point of The belt must be pre-tensioned so that it can transmit the
application of force FQ and the shaft shoulder. circumferential force through friction. The pre-tension
Dimension xmax. corresponds to the length of the shaft factor indicates how much higher the actual tension
extension. Total cantilever force is calculated using the load (cantilever force) is than the circumferential force
following equation. (peripheral force).
FQ = c · FU
Today, flat belts are almost always manufactured out of
The pre-tension factor c is a value gained from experience plastic with an adhesive coating (e.g. chrome leather).
from the belt manufacturer. The following approximate Pre-tension factor, approx. 2 to 2.5.
value can be assumed. The pre-tension factor for V-belts is approx. 1.5 to 2.5.
 For normal flat leather belts with an idler pulley, c = 2.
The belt must be able to transmit the power at the defined
 For v-belts, c = 2 to 2.5. circumferential velocity. This defines the belt thickness and
width. The belt supplier specifies the pre-tension factor.
 For special synthetic belts
The recommended circumferential velocity is approx.
(depending on the type and load), c = 2 to 2.5.
35 m/s for flat belts and approx. 25 m/s for V-belts.
The circumferential force FU(N) is calculated using the Steel belt pulleys must be used for circumferential veloci-
following equation. ties greater than 26 m/s due to the centrifugal force which
P
FU = 2 · 107 occurs.
nxD
FU = circumferential force in N The actual cantilever force (belt tension) must be
P = rated motor power (transmitted power) in kW compared with the cantilever force permissible for the
n = rated motor speed motor to select the correct motor and bearing sizes.
D = pulleys in mm.

Chapter 3 · Special features detail 47


© Siemens AG 2014

Bearing – Bearing types


Standard bearing assignment
SIMOTICS Gen
Aluminum Series
Efficiency IE1
Frame Number 1LA7 1LE1002
size of poles
Non-drive end Non-drive end Non-drive end Non-drive end
Drive end (Horizontal (Vertical Drive end (Horizontal (Vertical Drive end
mounting) mounting) mounting) mounting)
2 6201 2Z C3 6201 2Z C3 6201 2Z C3 - - - -
63 4 6201 2Z C3 6201 2Z C3 6201 2Z C3 - - - -
6 6201 2Z C3 6201 2Z C3 6201 2Z C3 - - - -
2 6202 2Z C3 6202 2Z C3 6202 2Z C3 - - - -
71 4 6202 2Z C3 6202 2Z C3 6202 2Z C3 - - - -
6 6202 2Z C3 6202 2Z C3 6202 2Z C3 - - - -
2 6004 2Z C3 6004 2Z C3 6004 2Z C3 - - - 6004 2Z C3
80 4 6004 2Z C3 6004 2Z C3 6004 2Z C3 - - - 6004 2Z C3
6 6004 2Z C3 6004 2Z C3 6004 2Z C3 - - - 6004 2Z C3
2 6205 2Z C3 6004 2Z C3 6004 2Z C3 - - - 6205 2Z C3
90 4 6205 2Z C3 6004 2Z C3 6004 2Z C3 - - - 6205 2Z C3
6 6205 2Z C3 6004 2Z C3 6004 2Z C3 - - - 6205 2Z C3
2 - - - 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3
100 4 - - - 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3
6 - - - 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3
2 - - - 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3
112 4 - - - 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3
6 - - - 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3
2 - - - 6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3
132 4 - - - 6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3
6 - - - 6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3
2 - - - 6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3
160 4 - - - 6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3
6 - - - 6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3
2 - - - - - - -
180 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
200 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
225 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
250 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
280 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
315 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
355 4 - - - - - - -
6 - - - - - - -

48 Chapter 3 · Special features detail


© Siemens AG 2014

neral Purpose
Cast Iron Series
Efficiency IE2 Efficiency IE1 Efficiency IE2
1LE1001 1LE0102 1LE0101
Non-drive end Non-drive end Non-drive end Non-drive end Non-drive end Non-drive end
(Horizontal (Vertical Drive end (Horizontal (Vertical Drive end (Horizontal (Vertical
mounting) mounting) mounting) mounting) mounting) mounting)
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
6004 2Z C3 6004 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3
6004 2Z C3 6004 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3
6004 2Z C3 6004 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3 6204 2Z C3
6004 2Z C3 6004 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3
6004 2Z C3 6004 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3
6004 2Z C3 6004 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3 6205 2Z C3
6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3
6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3
6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3
6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3
6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3
6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3
6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3
6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3 6308 2Z C3 6208 2Z C3 6208 2Z C3
6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3 6208 2Z C3 6308 2Z C3 6208 2Z C3 6208 2Z C3
6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3
6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3 6309 2Z C3 6209 2Z C3 6209 2Z C3
6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3 6209 2Z C3 6309 2Z C3 6209 2Z C3 6209 2Z C3
- - 6210 Z C3 6210 Z C3 6210 Z C3 6210 Z C3 6210 Z C3 6210 Z C3
- - 6210 Z C3 6210 Z C3 6210 Z C3 6310 Z C3 6210 Z C3 6210 Z C3
- - 6210 Z C3 6210 Z C3 6210 Z C3 6310 Z C3 6210 Z C3 6210 Z C3
- - 6212 Z C3 6212 Z C3 6212 Z C3 6212 Z C3 6212 Z C3 6212 Z C3
- - 6212 Z C3 6212 Z C3 6212 Z C3 6312 Z C3 6212 Z C3 6212 Z C3
- - 6212 Z C3 6212 Z C3 6212 Z C3 6312 Z C3 6212 Z C3 6212 Z C3
- - 6213 Z C3 6213 Z C3 6213 Z C3 6213 Z C3 6213 Z C3 6213 Z C3
- - 6213 Z C3 6213 Z C3 6213 Z C3 6313 Z C3 6213 Z C3 6213 Z C3
- - 6213 Z C3 6213 Z C3 6213 Z C3 6313 Z C3 6213 Z C3 6213 Z C3
- - 6215 C3 6215 C3 7215 AC 6215 C3 6215 C3 7215 AC
- - 6215 C3 6215 C3 7215 AC 6315 C3 6215 C3 7215 AC
- - 6215 C3 6215 C3 7215 AC 6315 C3 6215 C3 7215 AC
- - 6317 C3 6317 C3 7317 AC 6317 C3 6317 C3 7317 AC
- - 6317 C3 6317 C3 7317 AC 6317 C3 6317 C3 7317 AC
- - 6317 C3 6317 C3 7317 AC 6317 C3 6317 C3 7317 AC
- - 6319 C3 6319 C3 7319 AC 6319 C3 6319 C3 7319 AC
- - 6319 C3 6319 C3 7319 AC 6319 C3 6319 C3 7319 AC
- - 6319 C3 6319 C3 7319 AC 6319 C3 6319 C3 7319 AC
- - 6319 C3 6319 C3 7319 AC 6319 C3 6319 C3 7319 AC
- - 6322 C3 6322 C3 7322 AC 6322 C3 6322 C3 7322 AC
- - 6322 C3 6322 C3 7322 AC 6322 C3 6322 C3 7322 AC

Chapter 3 · Special features detail 49


© Siemens AG 2014

Bearing – Bearing types


Bearing design for increased cantilever forces
SIMOTICS Gen
Aluminum Series
Efficiency IE1
Frame Number 1LA7 1LE1002
size of poles
Non-drive end Non-drive end Non-drive end Non-drive end
Drive end (Horizontal (Vertical Drive end (Horizontal (Vertical Drive end
mounting) mounting) mounting) mounting)
2 - - - - - - -
63 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
71 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
80 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
90 4 - - - - - - -
6 - - - - - - -
2 - - - 6306 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3
100 4 - - - 6306 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3
6 - - - 6306 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3
2 - - - 6306 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3
112 4 - - - 6306 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3
6 - - - 6306 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3
2 - - - 6308 2Z C3 6208 2Z C3 6208 2Z C3 6308 2Z C3
132 4 - - - 6308 2Z C3 6208 2Z C3 6208 2Z C3 6308 2Z C3
6 - - - 6308 2Z C3 6208 2Z C3 6208 2Z C3 6308 2Z C3
2 - - - 6309 2Z C3 6209 2Z C3 6209 2Z C3 6309 2Z C3
160 4 - - - 6309 2Z C3 6209 2Z C3 6209 2Z C3 6309 2Z C3
6 - - - 6309 2Z C3 6209 2Z C3 6209 2Z C3 6309 2Z C3
2 - - - - - - -
180 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
200 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
225 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
250 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
280 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
315 4 - - - - - - -
6 - - - - - - -
2 - - - - - - -
355 4 - - - - - - -
6 - - - - - - -

50 Chapter 3 · Special features detail


© Siemens AG 2014

Did you know ?


When the load pulls sideways on the shaft, it is called a radial load.
A heavy radial load is a belt or pulley drive.
If in doubt, it is common to use “C63” or strengthened bearings.

neral Purpose
Cast Iron Series
Efficiency IE2 Efficiency IE1 Efficiency IE2
1LE1001 1LE0102 1LE0101
Non-drive end Non-drive end Non-drive end Non-drive end Non-drive end Non-drive end
(Horizontal (Vertical Drive end (Horizontal (Vertical Drive end (Horizontal (Vertical
mounting) mounting) mounting) mounting) mounting) mounting)
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3
6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3
6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3
6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3
6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3 - - -
6206 2Z C3 6206 2Z C3 6306 2Z C3 6206 2Z C3 6206 2Z C3 - - -
6208 2Z C3 6208 2Z C3 6308 2Z C3 6208 2Z C3 6208 2Z C3 6308 2Z C3 6208 2Z C3 6208 2Z C3
6208 2Z C3 6208 2Z C3 6308 2Z C3 6208 2Z C3 6208 2Z C3 - - -
6208 2Z C3 6208 2Z C3 6308 2Z C3 6208 2Z C3 6208 2Z C3 - - -
6209 2Z C3 6209 2Z C3 6309 2Z C3 6209 2Z C3 6209 2Z C3 6309 2Z C3 6209 2Z C3 6209 2Z C3
6209 2Z C3 6209 2Z C3 6309 2Z C3 6209 2Z C3 6209 2Z C3 - - -
6209 2Z C3 6209 2Z C3 6309 2Z C3 6209 2Z C3 6209 2Z C3 - - -
- - NU210 6210 Z C3 6210 Z C3 NU210 6210 Z C3 6210 Z C3
- - NU210 6210 Z C3 6210 Z C3 NU210 6210 Z C3 6210 Z C3
- - NU210 6210 Z C3 6210 Z C3 NU210 6210 Z C3 6210 Z C3
- - NU212 6212 Z C3 6212 Z C3 NU212 6212 Z C3 6212 Z C3
- - NU212 6212 Z C3 6212 Z C3 NU212 6212 Z C3 6212 Z C3
- - NU212 6212 Z C3 6212 Z C3 NU212 6212 Z C3 6212 Z C3
- - NU213 6213 Z C3 6213 Z C3 NU213 6213 Z C3 6213 Z C3
- - NU213 6213 Z C3 6213 Z C3 NU213 6213 Z C3 6213 Z C3
- - NU213 6213 Z C3 6213 Z C3 NU213 6213 Z C3 6213 Z C3
- - NU215 6215 C3 7215 AC NU215 6215 C3 7215 AC
- - NU215 6215 C3 7215 AC NU215 6215 C3 7215 AC
- - NU215 6215 C3 7215 AC NU215 6215 C3 7215 AC
- - NU317 6317 C3 7317 AC NU317 6317 C3 7317 AC
- - NU317 6317 C3 7317 AC NU317 6317 C3 7317 AC
- - NU317 6317 C3 7317 AC NU317 6317 C3 7317 AC
- - NU319 6319 C3 7319 AC NU319 6319 C3 7319 AC
- - NU319 6319 C3 7319 AC NU319 6319 C3 7319 AC
- - NU319 6319 C3 7319 AC NU319 6319 C3 7319 AC
- - NU319 6319 C3 7319 AC NU319 6319 C3 7319 AC
- - NU322 6322 C3 7322 AC NU322 6322 C3 7322 AC
- - NU322 6322 C3 7322 AC NU322 6322 C3 7322 AC

Chapter 3 · Special features detail 51


© Siemens AG 2014

Bearing – Cantilever forces


Admissible cantilever forces for standard version
SIMOTICS General Purpose
Aluminum Series Cast Iron Series
Frame Number Efficiency IE1 Efficiency IE2 Efficiency IE1 Efficiency IE2
size of poles 1LA7 1LE1002 1LE1001 1LE0102 1LE0101
for x0 for xmax for x0 for xmax for x0 for xmax for x0 for xmax for x0 for xmax
N N N N N N N N N N
2 270 240 - - - - - - - -
63 4 350 305 - - - - - - - -
6 415 360 - - - - - - - -
2 415 355 - - - - - - - -
71 4 530 450 - - - - - - - -
6 630 535 - - - - - - - -
2 485 400 - - 485 400 620 510 620 510
80 4 625 515 - - 625 515 790 640 790 640
6 735 605 - - 735 605 910 740 910 740
2 725 605 - - 725 605 700 560 700 560
90 4 920 775 - - 920 775 880 720 880 720
6 1090 910 - - 1090 910 1020 820 1020 820
2 - - 1010 825 1010 825 980 790 980 790
100 4 - - 1230 1010 1230 1010 1230 990 1230 990
6 - - 1440 1180 1440 1180 1420 1140 1420 1140
2 - - 970 785 970 785 980 790 980 790
112 4 - - 1235 1000 1235 1000 1230 990 1870 1540
6 - - 1440 1165 1440 1165 1420 1140 2140 1720
2 - - 1470 1180 1470 1180 1440 1120 1440 1120
132 4 - - 1830 1470 1830 1470 1820 1420 2720 2170
6 - - 2150 1730 2150 1730 2080 1630 3100 2420
2 - - 1550 1270 1550 1270 1560 1240 1560 1240
160 4 - - 1910 1550 1910 1550 1970 1570 3300 2600
6 - - 2230 1810 2230 1810 2260 1800 3750 2900
2 - - - - - - 1820 1470 1820 1470
180 4 - - - - - - 2300 1900 4000 3300
6 - - - - - - 2630 2150 4500 3700
2 - - - - - - 2650 2230 2650 2230
200 4 - - - - - - 3350 2800 5400 4530
6 - - - - - - 3850 3230 6200 5200
2 - - - - - - 3000 2540 3000 2540
225 4 - - - - - - 3700 3000 5900 4800
6 - - - - - - 4250 3470 6800 5550
2 - - - - - - 3150 2620 3150 2620
250 4 - - - - - - 3950 3280 7350 6100
6 - - - - - - 4600 3820 8450 7000
2 - - - - - - 6600 5550 6600 5550
280 4 - - - - - - 8300 6950 8300 6950
6 - - - - - - 9650 8120 9650 8120
2 - - - - - - 7100 6200 7100 6200
315 4 - - - - - - 8700 7250 8700 7250
6 - - - - - - 10000 8500 10000 8500
2 - - - - - - 6800 6000 6800 6000
355 4 - - - - - - 11500 10000 11500 10000
6 - - - - - - 13200 11600 13200 11600

52 Chapter 3 · Special features detail


© Siemens AG 2014

Bearing design for increased cantilever forces


SIMOTICS General Purpose
Aluminum Series Cast Iron Series
Frame Number Efficiency IE1 Efficiency IE2 Efficiency IE1 Efficiency IE2
size of poles 1LA7 1LE1002 1LE1001 1LE0102 1LE0101
for x0 for xmax for x0 for xmax for x0 for xmax for x0 for xmax for x0 for xmax
N N N N N N N N N N
2 - - - - - - - - - -
63 4 - - - - - - - - - -
6 - - - - - - - - - -
2 - - - - - - - - - -
71 4 - - - - - - - - - -
6 - - - - - - - - - -
2 - - - - - - - - - -
80 4 - - - - - - - - - -
6 - - - - - - - - - -
2 - - - - - - - - - -
90 4 - - - - - - - - - -
6 - - - - - - - - - -
2 - - 1585 1300 1585 1300 1480 1220 1480 1220
100 4 - - 1960 1610 1960 1610 1870 1540 1870 1540
6 - - 2270 1865 2270 1865 2140 1720 2140 1720
2 - - 1545 1250 1545 1250 1480 1220 1480 1220
112 4 - - 1960 1585 1960 1585 1870 1540 - -
6 - - 2270 1835 2270 1835 2140 1720 - -
2 - - 2285 1840 2285 1840 2100 1700 2100 1700
132 4 - - 2860 2300 2860 2300 2720 2170 - -
6 - - 3320 2670 3320 2670 3100 2420 - -
2 - - 2800 2240 2800 2240 2650 2120 2650 2120
160 4 - - 3450 2270 3450 2270 3300 2600 - -
6 - - 4000 3200 4000 3200 3750 2900 - -
2 - - - - - - 3300 2700 3300 2700
180 4 - - - - - - 4200 3400 4200 3400
6 - - - - - - 4750 3900 4750 3900
2 - - - - - - 5000 4200 5000 4200
200 4 - - - - - - 6330 5320 6330 5320
6 - - - - - - 7250 6080 7250 6080
2 - - - - - - 5650 4800 5650 4800
225 4 - - - - - - 6950 5600 6950 5600
6 - - - - - - 7900 6500 7900 6500
2 - - - - - - 6700 5600 6700 5600
250 4 - - - - - - 8500 7000 8500 7000
6 - - - - - - 9500 7800 9500 7800
2 - - - - - - 11500 9500 11500 9500
280 4 - - - - - - 17000 14000 17000 14000
6 - - - - - - 20000 17000 20000 17000
2 - - - - - - 14600 12300 14600 12300
315 4 - - - - - - 20000 16500 20000 16500
6 - - - - - - 23000 19000 23000 19000
2 - - - - - - 15800 14000 15800 14000
355 4 - - - - - - 22000 19000 22000 19000
6 - - - - - - 25000 22000 25000 22000

Chapter 3 · Special features detail 53


© Siemens AG 2014

Terminal box

TIP
The terminal box is located on the top of the motor
housing as standard, and can be rotated by 4 x 90º
– on some 1LE1 even 360° – to allow for cable entry
from each direction.
All terminal boxes have two cable entries sealed by a
screwed plug.

1LA7
Aluminum Series
Efficiency IE1

Frame 1LA7
size Number Contact Max. con- Outer cable Cable
of screw nectable diameter entry size
terminals thread cross-section (sealing (screwed
(mm2) range) plug)
1xM25x1.5 +
63 6 M4 1.5 9 ... 17
1xM16x1.5
1xM25x1.5 +
71 6 M4 1.5 9 ... 17
1xM16x1.5
1xM25x1.5 +
80 6 M4 1.5 9 ... 17
1xM16x1.5
1xM25x1.5 +
90 6 M4 1.5 9 ... 17
1xM16x1.5

1LE10
Aluminum Series
Efficiency IE1 Efficiency IE2

Frame 1LE1002 1LE1001


size Number Contact Max. con- Outer cable Cable entry Number Contact Max. con- Outer cable Cable entry
of screw nectable diameter size of screw nectable diameter size
terminals thread cross-section (sealing (screwed terminals thread cross-section (sealing (screwed
(mm2) range) plug) (mm2) range) plug)
1xM25x1.5 +
80 – – – – – 6 M3.5 1.5 9 ... 17
1xM16x1.5
1xM25x1.5 +
90 – – – – – 6 M3.5 1.5 9 ... 17
1xM16x1.5

100 6 M4 4 11 ... 21 2xM32x1.5 6 M4 4 11 ... 21 2xM32x1.5

112 6 M4 4 11 ... 21 2xM32x1.5 6 M4 4 11 ... 21 2xM32x1.5

132 6 M4 6 11 ... 21 2xM32x1.5 6 M4 6 11 ... 21 2xM32x1.5

160 6 M5 16 19 ... 28 2xM40x1.5 6 M5 16 19 ... 28 2xM40x1.5

Motors with an aluminum housing are particularly user The terminal box is only fixed with one screw and can be
friendly. The terminal box introduced for frame sizes rotated steplessly by up to 360°. The terminal box is also
100 to 160 has proven its worth and is consistently imple- preconfigured with a terminal board. This makes instal-
mented throughout the motor series for 2- and 4-pole lation quicker and easier in confined spaces as the motor
motors of frame sizes 80 and 90. connection cables can be fed in from any direction.

54 Chapter 3 · Special features detail


© Siemens AG 2014

1LE0
Cast Iron Series
Efficiency IE1 Efficiency IE2

Frame 1LE0102 1LE0101


size Number Contact Max. con- Outer cable Cable entry Number Contact Max. con- Outer cable Cable entry
of screw nectable diameter size of screw nectable diameter size
terminals thread cross-section (sealing (screwed terminals thread cross-section (sealing (screwed
(mm2) range) plug) (mm2) range) plug)
M25 x 1.5 + M25 x 1.5 +
80 6 M4 1.5 13 ... 18 6 M4 1.5 13 ... 18
M16 x 1.5 M16 x 1.5
M25 x 1.5 + M25 x 1.5 +
90 6 M4 1.5 13 ... 18 6 M4 1.5 13 ... 18
M16 x 1.5 M16 x 1.5
M32 x 1.5 + M32 x 1.5 +
100 6 M4 4 18 ... 25 6 M4 4 18 ... 25
M32 x 1.5 M32 x 1.5
M32 x 1.5 + M32 x 1.5 +
112 6 M4 4 18 ... 25 6 M4 4 18 ... 25
M32 x 1.5 M32 x 1.5
M32 x 1.5 + M32 x 1.5 +
132 6 M4 6 18 ... 25 6 M4 6 18 ... 25
M32 x 1.5 M32 x 1.5
M40 x 1.5 + M40 x 1.5 +
160 6 M5 16 22 ... 32 6 M5 16 22 ... 32
M40 x 1.5 M40 x 1.5
M40 x 1.5 + M40 x 1.5 +
180 6 M5 16 22 ... 32 6 M5 16 22 ... 32
M40 x 1.5 M40 x 1.5
M50 x 1.5 + M50 x 1.5 +
200 6 M6 25 32 ... 38 6 M6 25 32 ... 38
M50 x 1.5 M50 x 1.5
M50 x 1.5 + M50 x 1.5 +
225 6 M8 35 32 ... 38 6 M8 35 32 ... 38
M50 x 1.5 M50 x 1.5
M63 x 1.5 + M63 x 1.5 +
250 6 M10 120 37 ... 44 6 M10 120 37 ... 44
M63 x 1.5 M63 x 1.5
M63 x 1.5 + M63 x 1.5 +
280 6 M10 120 37 ... 44 6 M10 120 37 ... 44
M63 x 1.5 M63 x 1.5
M63 x 1.5 + M63 x 1.5 +
315 6 M12 240 37 ... 44 6 M12 240 37 ... 44
M63 x 1.5 M63 x 1.5
M72 x 2 + M72 x 2 +
355 6 M20 240 44 ... 57 6 M20 240 44 ... 57
M72 x 2 M72 x 2

Chapter 3 · Special features detail 55


© Siemens AG 2014

SIMOTICS General Purpose


Low-Voltage Motors
1LE0 option line
The 1LE0 option line is a new set of motors offering 1LE0 option line for general industrial applications
extended options and voltages based on the 1LE0 motor Frame size 80 to 355
family. This broadens the 1LE0 portfolio to fulfill a wider Power range 0.55 kW to 315 kW
range of requirements for motor specifications in different (referred to 1,500 rpm rated speed)
environments and applications. The article number of Number of poles 2, 4 and 6 poles
the 1LE0 option line (1LE002) is different to the 1LE0 Motor material Frame and terminal box: Cast iron
distribution line (1LE010). The basic motor of the 1LE0 Article number and 1LE0022: IE1 Improved efficiency
option line is a standard motor without any included Efficiency class 1LE0021: IE2 High efficiency
features. A wide range of options can be added into the 230 V to 690 V, selectable according list
Voltages
configuration as needed. As a highlight, options like of voltage codes
PTC, condensation drain hole and bearing for increased Direct-on-line operation upto 690 V,
Insulation system
cantilever force are included as standard in the 1LE0 dis- Converter-fed upto 460 V + tolerance
tribution line only. Temperature class 155 (F) utilization to 130 (B)
Additional options of the 1LE0 option line are designed to Standard – 20 °C to + 40 °C ,
Ambient temperature
suit the different requirements of the customer. They also optional – 40 °C to + 40 °C
enhance the distribution portfolio to project specifications Standard IMB3 and other types of
Construction type
and specific OEM machines. construction as option
Degree of protection IP55, optional IP56
Winding protection Optional PTC, PT100 and KTY84-130
Encoder and separated driven fan
Modular concept
as option

M
G_D081_XX_00092

LL 861 900 220 encoder, Option G04 Separately driven fan, Option F70

56 Chapter 4 · 1LE0 option line


© Siemens AG 2014

Product highlights
1. Wide range of options – can be selected according to
specific customer requirements. The basic 1LE0 option line
motor is a standard motor without any built-in features.

2. Fulfill voltage and construction requirements – The


motor line offers additional selection of rated voltages and
mounting types.

3. Easy retrofit and upgrade – due to harmonized design


dimensions throughout the whole 1LE0 motor family.

4. Common user and spare parts – are applicable within


the 1LE0 motor line.
Pump
5. Increase plant and system availability – Options of
winding protection, insulated bearing and separately
driven fan enhance the availability and thus reliability of
the system.

6. Global support – worldwide warranty and service

Application note
• Pump: Energy saving for quadratic torque load with
variable speed operation
• Fan: Ideal for flow control application
• Material handling: Effectively working with continuous
and intermittent periodic duties. Reliable operation.

Fan

Material handling

Chapter 4 · 1LE0 option line 57


© Siemens AG 2014

Flexible control options


With separately driven fan, the motor can be worked with
Highlight features
inverter in constant torque operation. This is the result of
continuous full speed ventilation of forced fan option.
Working with SINAMICS, you can rely on a drive family
with flexible control options – with V/f control as well as
vector control. As a result, applications can be addressed
with basic speed control and with higher speed precision
with encoderless vector control or with encoder.

100

G_D081_EN_00415
80
Rated torque [%]

60
40
20 Highlight motor options
0 • Insulated bearing, encoder and separately driven
05 0 100 150 fan to increase reliability for converter-fed operation
Rated frequency [%]
• KTY84-130 and PT100 sensors are additional
Forced ventilation Motor self ventilation
protections that can evaluate motor temperature
for alarm and tripping.
• Measuring nipple for SPM shock pulse measurement
for bearing inspection
• Vibration severity level B according to IEC 60034-14
• Rotation of terminal box on right or left hand side of
the motor drive end
• Additional degree of protection IP56
G_D081_XX_00096

Motor with encoder and separated driven fan

58 Chapter 4 · 1LE0 option line


© Siemens AG 2014

Article number explanation

Structure of Article No. (1LE0 option line)


Structure Position: 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z
Position 1 to 6: Low-voltage motor series
• 1LE0 option line 1 L E 0 0 2
Position 7: Motor efficiency
• Motor with high efficiency - IE2 1
• Motor with improved efficiency - IE1 2
Position 8 to 11: Frame size, number of poles and frame length
Refer to page 14
Position 12 and 13: Voltage, circuit and frequency
• 22 = 230 VD/400 VY 50 Hz
• 34 = 400 VD/690 VY 50 Hz
• 35 = 415 VD 50 Hz
• 21 = 220 VD/380 VY 50 Hz
• 33 = 380 VD/660 VY 50 Hz
• 90 = special voltage & frequency
• 23 = 240 VD/415 VY 50 Hz
• 41 = 525 VD 50 Hz
Position 14: Type of construction (refer to page 17)
• A = IM B3
• J = IM B35
• F = IM B5
• G = IM V1
• K = IM B14
• T = IM B6
• U = IM B7
• V = IM B8
• C = IM V5
• D = IM V6
• N = IM B34
• M = IM V18
• L = IM V19
• W = IM V15
• Y = IM V35
• G = IM V1
• H = IM V3
Position 15: Motor protection
• A = without winding protection
• B = 3 PTC thermistors for tripping
• C = 6 PTC thermistors for alarm and tripping
• F = 1 temperature sensor KTY 84-130
• H = 3 resistance thermometers Pt100
• J = 6 resistance thermometers Pt100
Position 16: Terminal box location (view from drive end)
• 4 = on top
• 5 = on RHS
• 6 = on LHS
Special order version
Coded - Order (option) code also required

Ordering example
1LE0021 – 1DB43 – 4AH4-Z, F70+B02
1LE0 option line motor, IE2 high efficiency motor, FS160, 4 poles, 400 VD/690 VY 50 Hz, IM B3, 3 resistance thermometers PT100,
terminal box on top included separated driven fan (F70) and Acceptance test certificate 3.1 in accordance with EN 10204 (B02).

Chapter 4 · 1LE0 option line 59


© Siemens AG 2014

List of options

Remark: The basic 1LE0 extended option motor does not include any option as standard.

Motor Position of article No. Option code1) Description


frame size 12th & 13th
Voltage and frequency
FS80 ~ 132 21 220 VD / 380 VY 50 Hz 2)
FS100 ~ 355 33 380 VD / 660 VY 50 Hz 2)
FS80 ~ 132 22 230 VD / 400 VY 50 Hz 2)
FS100 ~ 355 34 400 VD / 690 VY 50 Hz 2)
FS80 ~ 355 23 240 VD / 415 VY 50 Hz
FS80 ~ 355 35 415 VD 50 Hz
FS80 ~ 355 41 525 VD 50 Hz
FS80 ~ 355 90 M2A 220 VD / 380 VY 60 Hz (50 Hz output)
FS80 ~ 355 90 M2B 380 VD 60 Hz (50 Hz output)
FS80 ~ 355 90 M2C 440 VY 60 Hz (50 Hz output)
FS80 ~ 355 90 M2D 440 VD 60 Hz (50 Hz output)
FS80 ~ 355 90 M2E 460 VY 60 Hz (50 Hz output)
FS80 ~ 355 90 M2F 460 VD 60 Hz (50 Hz output)
Motor Position of article No. Option code1) Description
frame size 15th
Motor protection
Without motor protection
FS80 ~ 355 A2)

Motor protection with PTC thermistors with three embedded


FS80 ~ 355 B
temperature sensors for tripping
Motor protection with PTC thermistors with 6 embedded
FS80 ~ 355 C
temperature sensors for alarm and tripping
Motor temperature detection with embedded temperature
FS100 ~ 355 F
sensor KTY 84-130
FS80 ~ 355 H Installation of three PT100 resistance thermometers
FS80 ~ 355 J Installation of six PT100 resistance thermometers
Motor Position of article No. Option code1) Description
frame size 16th
Motor terminal box
FS80 ~ 355 4 Terminal box top
FS80 ~ 355 5 Terminal box on RHS
FS80 ~ 355 6 Terminal box on LHS
FS80 ~ 355 R103) Rotation of the terminal box through 90°, entry from DE
FS80 ~ 355 R11 Rotation of the terminal box through 90°, entry from NDE
FS80 ~ 355 R12 Rotation of the terminal box through 180°
FS80 ~ 355 H084) Terminal box on NDE
Winding and Insulation
FS80 ~ 355 N01 Temperature class 155 (F), used acc. to 155 (F), with service factor (SF)
FS80 ~ 355 N10 Temperature class 180 (H)
FS80 ~ 355 Q04 Anti-condensation heating for 220 V
FS80 ~ 355 Q02 Anti-condensation heating for 230 V

60 Chapter 4 · 1LE0 option line


© Siemens AG 2014

TIP
In the basic bearing system, the located bearing is at the NDE or the bearing at the NDE is fixed. And the bearing at
the DE is free or “floating”. Therefore it allows thermal (axial) growth of the shaft. In case of pump application with
vertical mounting, the axial and trust load have to be considered and L20 option, located bearing at DE, is recom-
mended.

Motor Option code1) Description


frame size
Bearing
FS100 ~ 355 L22 Bearing design for increased cantilever forces
FS80 ~ 160 L20 Located bearing DE
FS100 ~ 250 L235) Regreasing device
FS180 ~ 355 Q72 Installation of 2 PT100 screw-in resistance thermometers for bearings
FS250 ~ 355 L536) Insulated bearing
FS100 ~ 355 Q01 Measuring nipple for SPM shock pulse measurement for bearing inspection
Balance and vibration quantity
FS80 ~ 355 L00 Vibration quantity level B
Mechanical design and degree of protection
FS80 ~ 355 L057)8) Second standard shaft extension, NDE
FS80 ~ 355 H009) Protective cover (canopy)
FS80 ~ 355 H0310) Condensation drainage holes
FS80 ~ 280 H0411) External earthing
FS80 ~ 355 H22 IP56 degree of protection (non-heavy-sea)
Modular technology
FS80 ~ 355 F7012) Mounting of separately driven fan
FS80 ~ 355 F9013) Without external fan and without fan cover
FS80 ~ 355 F76 Metal fan
FS112 ~ 355 G04 Mounting of LL 861 900 220 rotary pulse encoder
Rating plate and test certificates
FS80 ~ 355 B02 Acceptance test certificate 3.1 according to EN 10204
Paint finish
FS80 ~ 355 S01 Unpainted, only primed
Coolant temperature
FS80 ~ 355 D03 Coolant temperature –40 to +40 °C

1) Article No. supplement Z with option code when ordering.


2) Without additional charge.
3) For FS80 to 112 motor, R10 only in combination with option code H08 (Terminal box on NDE) possible.
4) Cable entry on terminal box towards the non-drive end.
5) FS280, FS315 and FS355 motor with the regreasing device as standard.
6) For horizontal mounting motor, the insulated bearing is located at NDE. For vertical mounting motor, the insulated bearing

is located at DE.
7) Not possible in combination with canopy or separately driven fan (order code: F70).
8) Second standard shaft extension on NDE is smaller than DE and provides output at the level of the next smaller frame size.
9) Only applicable for the construction type IM V5, IM V1, IM V15 and IM V18. Not possible in combination with option code L05.
10) Position of the condensation drainage hole will be adapted to the construction type of the motor accordingly.
11) FS315 and FS355 motor with external earthing as standard.
12) When the separately driven fan is mounted, the length of the motor increases by ΔL.
13) Without fan and fan cover, the length of the motor decreases by Δl. By using the power output of rating plate, the motor must have external

cooling by air flow. The correct motor cooling is in responsibility of customer. Missing or wrong cooling reduces the life time or damages the
motor.

Chapter 4 · 1LE0 option line 61


© Siemens AG 2014

Dimensional drawings
IM B3

L
LL AG
BE AS

AD
AF
Ø AC
ØD
F

GA BC
HA

H
DB
EB

G_D081_XX_00370
ED ØK Ø K'
BA BA' AA AA
BB A
E C B AB

IM B35

For flange dimensions, see Page 58 (Z = the number of retaining holes)

L
LL AG
LE BE AS
T
ED

ZxS
AD
AF

EB
M
Ø AC
ØD
ØN
ØP
F

BC
GA
H

DB

G_D081_XX_00371
ØK Ø K'
HA

BA BA' AA AA
LA
BB A
E C B AB

62 Chapter 5 · Dimensional drawings


© Siemens AG 2014

IM B5 and IM V1

For flange dimensions, see Page 58 (Z = the number of retaining holes)

L
LL AG
LE BE AS
T
ED

ZxS

AD
AF
EB
M

Ø AC
ØD
ØN
ØP
F

GA
DB

G_D081_XX_00372
LA
E HH

IM B14

For flange dimensions, see Page 58 (Z = the number of retaining holes)

L
LL AG
LE BE AS

T
ED
ZxS
AD
AF

EB
Ø AC
ØD
ØN
ØP
F

GA

DB G_D081_XX_00373
E HH M

Chapter 5 · Dimensional drawings 63


© Siemens AG 2014

Aluminum series – 1LA7


For motor Dimension designation acc. to IEC
Frame Type Number A AA AB AC1) AD2) AD’ AF2) AF' AG2) AS B* BA BA' BB BC BE2) BE’2) C CA* H HA
size of poles
63 M 1LA7060 2, 4, 6 100 27 120 124 101 101 78 78 75 37.5 80 28 – 96 30 32 18 40 66 63 7
1LA7063
71 M 1LA7070 2, 4, 6 112 27 132 145 111 111 88 88 75 37.5 90 27 – 106 18 32 18 45 83 71 7
1LA7073
80 M 1LA7080 2, 4, 6 125 30.5 150 163 120 120 97 97 75 37.5 100 32 – 118 14 32 18 50 94 80 8
1LA7083 2, 4, 6
90 S 1LA7090 2, 4, 6 140 30.5 165 180 128 128 105 105 75 37.5 100 33 54 143 23 32 18 56 143 90 10
90 L 1LA7096 2, 4, 6 125 118
100 L 1LA7106 2, 4, 6 160 42 196 203 135 163 78 123 120 60 140 47 – 176 39 42 21 63 125 100 12
1LA7107 2 195 3)

* This dimension is assigned in DIN EN 50347 to the frame size listed.


1) Measured across the bolt heads.
2) The values increase if the terminal box is rotated or if a brake is mounted.
Further information is provided by the dimension sheet generator in the DT Configurator.
3) Only for 1LA7107-4PM.

Aluminum series – 1LE10


For motor Dimension designation acc. to IEC
Frame Number A AA AB AC AD AD’ AF AF' AG AS B* BA BA' BB BC BE BE’ C1) CA* H HA Y1)
size of poles
80 M 2, 4, 6 125 30.5 150 159 121 – 96.5 – 93 43 100 32 – 118 23 – 182) 50 – 80 8 41
90 S 2, 4, 6 140 30.5 165 178 126 – 101.5 – 93 43 100 33 – 143 22.5 – 182) 56 – 90 10 47
90 L 2, 4, 6 140 30.5 165 178 126 – 101.5 – 93 43 125 33 – 143 22.5 – 182) 56 – 90 10 47
100 L 2, 4, 6 160 42 196 198 166 166 125.5 125.5 135 63.5 140 37.5 – 176 33.5 50 25 63 141 100 12 45
112 M 2, 4, 6 190 46 226 222 177 177 136.5 136.5 135 63.5 140 35.4 – 176 26 50 25 70 129.7 112 12 52
132 S 2, 4, 6 216 53 256 262 202 202 159.5 159.5 155 70.5 140 38 763) 2184) 26.5 48 24 89 128.55) 132 15 69
132 M 2, 4, 6 216 53 256 262 202 202 159.5 159.5 155 70.5 178 38 76 218 26.5 48 24 89 128.55) 132 15 69
160 M 2, 4, 6 254 60 300 314 236.5 236.5 190 190 175 77.5 210 44 896) 3007) 47 57 28.5 108 1488) 160 18 85
160 L 2, 4, 6 254 60 300 314 236.5 236.5 190 190 175 77.5 254 44 89 300 47 57 28.5 108 1488) 160 18 85

* This dimension is assigned in DIN EN 50347 to the frame size listed.


1) Additional information – not a standard dimension according to DIN EN 50347.
2) Connecting hole for terminal box is on the side at the rear of the terminal box.
3) With screwed-on feet, dimension BA’ is 38 mm.
4) With screwed-on feet, dimension BB is 180 mm.
5) With screwed-on feet, dimension CA is 166.5 mm.
6) With screwed-on feet, dimension BA’ is 44 mm.
7) With screwed-on feet, dimension BB is 256 mm.
8) With screwed-on feet, dimension CA is 192 mm.
9) The length is specified as far as the tip of the fan cover.

64 Chapter 5 · Dimensional drawings


© Siemens AG 2014

Aluminum series – 1LA7


For motor Dimension designation acc. to IEC DE shaft extension
Frame Type Number HH K K’ L LC LL LM D DB E EB ED F GA
size of poles
63 M 1LA7060 2, 4, 6 69.5 7 10 202.5 1) 232 1) 75 231.5 1) 11 M4 23 16 3.5 4 12.5
1LA7063
71 M 1LA7070 2, 4, 6 63.5 7 10 240 278 75 268 14 M5 30 22 4 5 16
1LA7073
80 M 1LA7080 2, 4, 6 63.5 9.5 13.5 273.5 324 75 299.5 19 M6 40 32 4 6 21.5
1LA7083 2, 4, 6 364
90 S 1LA7090 2, 4, 6 79 10 14 331 389 75 382.5 24 M8 50 40 5 8 27
90 L 1LA7096 2, 4, 6
100 L 1LA7106 2, 4, 6 102 12 16 372 438 120 423.5 28 M10 60 50 5 8 31
1LA7107 2 442 3) 508 3) 493 3)

Aluminum series – 1LE10


For motor Dimension designation acc. to IEC DE shaft extension
Frame Number HH K K' L L1 D1 LC LL LM D DB E EB ED F GA
size of poles
80 M 2, 4, 6 73 9.5 13.5 292 – – – 79 – 19 M6 40 32 4 6 21.5
90 S 2, 4, 6 78.5 10 14 347 – – – 79 – 24 M8 50 40 5 8 27
90 L 2, 4, 6 78.5 10 14 347 – – – 79 – 24 M8 50 40 5 8 27
100 L 2, 4, 6 96.5 12 16 395.5 9) 7 32 454 112 428.5 28 M10 60 50 5 8 31
112 M 2, 4, 6 96 12 16 389 9) 7 32 450 112 422 28 M10 60 50 5 8 31
132 S 2, 4, 6 115.5 12 16 465 9) 8.5 39 535.5 130 516.5 38 M12 80 70 5 10 41
132 M 2, 4, 6 115.5 12 16 465 9) 8.5 39 535.5 130 516.5 38 M12 80 70 5 10 41
160 M 2, 4, 6 155 15 19 604 9) 10 45 730 145 654 42 M16 110 90 10 12 45
160 L 2, 4, 6 155 15 19 604 9) 10 45 730 145 654 42 M16 110 90 10 12 45

Chapter 5 · Dimensional drawings 65


© Siemens AG 2014

Cast Iron series – 1LE0


For motor Dimension designation acc. to IEC
Frame Motor Num-
size type ber of
1LE0- poles A AA AB AC1) AD/AD' AF/AF' AG AS B2) BA/BA' BB BC BE C CA* H HA
80 M 0D.2 2 125 36 160 157 142 110.5 161 65.5 100 44 135 26 42 50 103 80 10
0D.2 4, 6 125 36 160 157 142 110.5 161 65.5 100 44 135 26 42 50 103 80 10
0D.3 2, 4, 6 125 36 160 157 142 110.5 161 65.5 100 44 135 26 42 50 103 80 10
90 S 0E.0 2, 4, 6 140 46 175 175 152 120.5 161 65.5 100 46 140 20 42 56 115 90 10
90 L 0E.4 140 46 175 175 152 120.5 161 65.5 125 46 165 20 42 56 115 90 10
100 L 1A.4 2, 4, 6 160 45 200 196 177 140 175 70 140 45 176 30.5 54 63 133 100 12
1A.5 4 160 45 200 196 177 140 175 70 140 45 176 30.5 54 63 133 100 12
112 M 1B.2 2, 4, 6 190 45 226 221 188.5 152 175 70 140 50 180 22 54 70 129.5 112 12
132 S 1C.0 2, 4, 6 216 50 256 259 191.5 175 175 70 140 64 186 32.5 54 89 178 132 15
1C.1 2 216 50 256 259 191.5 175 175 70 140 64 186 32.5 54 89 178 132 15
132 M 1C.2 4, 6 216 50 256 259 191.5 175 175 70 178 64 224 32.5 54 89 185 132 15
1C.3 6 216 50 256 259 191.5 175 175 70 178 64 224 32.5 54 89 185 132 15
160 M 1D.2 2, 4, 6 254 60 314 312 255 206 231 94 210 70 258 51 68 108 194 160 20
1D.3 2 254 60 314 312 255 206 231 94 210 70 258 51 68 108 194 160 20
160 L 1D.4 2, 4, 6 254 60 314 312 255 206 231 94 254 70 302 51 68 108 210 160 20
180M 1E.2 2, 4 279 65 339 356 270 221 231 94 241 80 301 37 68 121 219 180 20
180L 1E.4 4, 6 279 65 339 356 270 221 231 94 279 80 339 37 68 121 216 180 20
200L 2A.4 2, 6 318 70 378 397 300 247.5 288 107.5 305 80 369 69 85 133 234 200 25
2A.5 2, 4, 6 318 70 378 397 300 247.5 288 107.5 305 80 369 69 85 133 234 200 25
225S 2B.0 4 356 80 436 442 327 274 288 107.5 286 80 348 63 85 149 255 225 34
225M 2B.2 2 356 80 436 442 327 274 288 107.5 311 80 373 63 85 149 255 225 34
4, 6
250M 2C.2 2 406 90 490 488 373 310.5 342 123 349 100 421 92 84 169 269 250 40
4, 6
280S 2D.0 2 457 100 540 538 413 350.5 342 123 368 115 454 72 84 190 237 280 40
4, 6
280M 2D.2 2 457 100 540 538 413 350.5 342 123 419 115 505 72 84 190 288 280 40
4, 6
315S 3A.0 2 508 120 610 608 482 401 401 148 406 165 520 75 110 216 351 315 50
4, 6
315M 3A.2 2 508 120 610 608 482 401 401 148 457/508 165 668 75 110 216 480 315 50
4, 6
315L 3A.5/3A.6/ 2 508 120 610 608 482 401 401 148 457/508 165 668 75 110 216 480 315 50
3A.7 4
3A.5/3A.6 6 508 120 610 608 482 401 401 148 457/508 165 668 75 110 216 480 315 50
355M 3B.2/3B.3 2 610 116 726 718 655 572 472 198.5 560/630 – 750 – 130 254 536 355 52
4, 6
3B.4 6 610 116 726 718 655 572 472 198.5 560/630 – 750 – 130 254 536 355 52
355L 3B.5/3B.6 2 610 116 726 718 655 572 472 198.5 560/630 – 750 – 130 254 536 355 52
4, 6

1) Measured across the bolt heads.


2) This dimension is assigned in DIN EN 50347 to the frame size listed.

66 Chapter 5 · Dimensional drawings


© Siemens AG 2014

For motor Dimension designation DE shaft extension


Frame size Motor Number acc. to IEC
type of poles
1LE0- HH K / K' L LC LL D DB E EB ED F GA
80 M 0D.2 2 76 10 288 323 109 19 M6 40 32 3.5 6 21.5
0D.2 4, 6 76 10 288 323 109 19 M6 40 32 3.5 6 21.5
0D.3 2, 4, 6 76 10 288 323 109 19 M6 40 32 3.5 6 21.5
90 S 0E.0 2, 4, 6 76 10 316 361 109 24 M8 50 40 3.5 8 27
90 L 0E.4 76 10 341 386 109 24 M8 50 40 3.5 8 27
100 L 1A.4 2, 4, 6 93.5 12 390 446 118 28 M10 60 50 3.5 8 31
1A.5 4 93.5 12 390 446 118 28 M10 60 50 3.5 8 31
112 M 1B.2 2, 4, 6 92 12 393.5 449.5 118 28 M10 60 50 3.5 8 31
132 S 1C.0 2, 4, 6 121.5 12 480 547 118 38 M12 80 70 4 10 41
1C.1 2 121.5 12 480 547 118 38 M12 80 70 4 10 41
132 M 1C.2 4, 6 121.5 12 525 592 118 38 M12 80 70 4 10 41
1C.3 6 121.5 12 525 592 118 38 M12 80 70 4 10 41
160 M 1D.2 2, 4, 6 159 15 614 701 158 42 M16 110 100 5 12 45
1D.3 2 159 15 614 701 158 42 M16 110 100 5 12 45
160 L 1D.4 2, 4, 6 159 15 674 761 158 42 M16 110 100 5 12 45
180M 1E.2 2, 4 158 15 683 801 158 48 M16 110 100 5 14 51.5
180L 1E.4 4, 6 158 15 718 836 158 48 M16 110 100 5 14 51.5
200L 2A.4 2, 6 202 19 772 892 215 55 M20 110 100 5 16 59
2A.5 2, 4, 6 202 19 772 892 215 55 M20 110 100 5 16 59
225S 2B.0 4 212 19 820 940 215 60 M20 140 125 5 18 64
225M 2B.2 2 212 19 815 935 215 55 M20 110 100 5 16 59
4, 6 845 965 60 140 125 18 64
250M 2C.2 2 260 24 917 1037 246 60 M20 140 125 5 18 64
4, 6 1067 65 69
280S 2D.0 2 262 24 976 1126 246 65 M20 140 125 5 18 69
4, 6 75 5 20 79.5
280M 2D.2 2 262 24 1027 1177 246 65 M20 140 125 5 18 69
4, 6 75 20 79.5
315S 3A.0 2 291 28 1113 1265 296 65 M20 140 125 6 18 69
4, 6 1143 1295 80 170 140 22 85
315M 3A.2 2 291 28 1293 1445 296 65 M20 140 125 6 18 69
4, 6 1323 1475 80 170 22 85
315L 3A.5/3A.6/ 2 291 28 1293 1445 296 65 M20 140 125 6 18 69
3A.7 4 1323 1475 80 170 140 22 85
3A.5/3A.6 6 291 28 1323 1475 296 80 M20 170 140 6 22 85
355M 3B.2/3B.3 2 298 28 1490 1652 397 75 M20 140 125 6 20 79.5
4, 6 1520 1712 95 M24 170 140 25 100
3B.4 6 298 28 1520 1712 397 95 M24 170 140 6 25 100
355L 3B.5/3B.6 2 298 28 1490 1652 397 75 M20 140 125 6 20 79.5
4, 6 1520 1712 95 M24 170 140 25 100

Chapter 5 · Dimensional drawings 67


© Siemens AG 2014

Flange dimensions
Type of construction – IM B5 Type of construction – IM B14

In DIN EN 50347, the frame


LE sizes are allocated flange
T FF with through holes and
flange FT with tapped holes.
The designation of flange
A and C according to
G_D081_XX_00026

G_D081_XX_00027
N
DIN 42948 (invalid since
M
September 2003) are also
listed for information pur-
poses. See the table below.
ZxS (Z = the number of retaining
holes).

Frame Type of construction Flange type Flange with Dimension designation acc. to IEC
size through holes (FF/A)
tapped holes (FT/C)
acc. to acc. to LA LE M N P S T Z
DIN EN 50347 DIN 42948
Aluminum series – 1LA7
63 M IM B5, IM B35, IM V1, IM V3 Flange FF 115 A 140 8 23 115 95 140 10 3 4
IM B14, IM B34, IM V18, IM V19 Standard flange FT 75 C 90 – 23 75 60 90 M5 2.5 4
IM B14, IM B34, IM V18, IM V19 Special flange FT 100 C 120 – 23 100 80 120 M6 3 4
71 M IM B5, IM B35, IM V1, IM V3 Flange FF 130 A 160 9 30 130 110 160 10 3.5 4
IM B14, IM B34, IM V18, IM V19 Standard flange FT 85 C 105 – 30 85 70 105 M6 2.5 4
IM B14, IM B34, IM V18, IM V19 Special flange FT 115 C 140 – 30 115 95 140 M8 3 4
80 M IM B5, IM B35, IM V1, IM V3 Flange FF 165 A 200 10 40 165 130 200 12 3.5 4
IM B14, IM B34, IM V18, IM V19 Standard flange FT 100 C 120 – 40 100 80 120 M6 3 4
IM B14, IM B34, IM V18, IM V19 Special flange FT 130 C 160 – 40 130 110 160 M8 3.5 4
90 S, IM B5, IM B35, IM V1, IM V3 Flange FF 165 A 200 10 50 165 130 200 12 3.5 4
90 L IM B14, IM B34, IM V18, IM V19 Standard flange FT 115 C 140 – 50 115 95 140 M8 3 4
IM B14, IM B34, IM V18, IM V19 Special flange FT 130 C 160 – 50 130 110 160 M8 3.5 4
100 L IM B5, IM B35, IM V1, IM V3 Flange FF 215 A 250 11 60 215 180 250 14.5 4 4
IM B14, IM B34, IM V18, IM V19 Standard flange FT 130 C 160 – 60 130 110 160 M8 3.5 4
IM B14, IM B34, IM V18, IM V19 Special flange FT 165 C 200 – 60 165 130 200 M10 3.5 4

68 Chapter 5 · Dimensional drawings


© Siemens AG 2014

Frame Type of construction Flange type Flange with Dimension designation acc. to IEC
size through holes (FF/A)
tapped holes (FT/C)
acc. to acc. to LA LE M N P S T Z
DIN EN 50347 DIN 42948
Aluminum series – 1LE10
80 M IM B5, IM B35, IM V1, IM V3 Flange FF 165 A 200 10 40 165 130 200 12 3.5 4
IM B14, IM B34, IM V18, IM V19 Standard flange FT 100 C 120 – 40 100 80 120 M6 3 4
90 S, IM B5, IM B35, IM V1, IM V3 Flange FF 165 A 200 10 50 165 130 200 12 3.5 4
90 L IM B14, IM B34, IM V18, IM V19 Standard flange FT 115 C 140 – 50 115 95 140 M8 3 4
100 L IM B5, IM B35, IM V1, IM V3 Flange FF 215 A 250 11 60 215 180 250 14.5 4 4
IM B14, IM B34, IM V18, IM V19 Standard flange FT 130 C 160 – 60 130 110 160 M8 3.5 4
IM B14, IM B34, IM V18, IM V19 Special flange FT 165 C 200 – 60 165 130 200 M10 3.5 4
(next larger
standard flange)
112 M IM B5, IM B35, IM V1, IM V3 Flange FF 215 A 250 11 60 215 180 250 14.5 4 4
IM B14, IM B34, IM V18, IM V19 Standard flange FT 130 C 160 – 60 130 110 160 M8 3.5 4
IM B14, IM B34, IM V18, IM V19 Special flange FT 165 C 200 – 60 165 130 200 M10 3.5 4
(next larger
standard flange)
132 S, IM B5, IM B35, IM V1, IM V3 Flange FF 265 A 300 12 80 265 230 300 14.5 4 4
132 M IM B14, IM B34, IM V18, IM V19 Standard flange FT 165 C 200 – 80 165 130 200 M10 3.5 4
IM B14, IM B34, IM V18, IM V19 Special flange FT 215 C 250 – 80 215 180 250 M12 4 4
(next larger
standard flange)
160 M, IM B5, IM B35, IM V1, IM V3 Flange FF 300 A 350 13 110 300 250 350 18.5 5 4
160 L IM B14, IM B34, IM V18, IM V19 Standard flange FT 215 C 250 – 110 215 180 250 M12 4 4
Cast Iron series – 1LE0
80 IM B5, IM B35, IMV1, IM V3 Flange FF 165 A 200 10 40 165 130 200 12 3.5 4
IM B14, IM V18, IM V19 Standard flange FT 100 C 120 - 40 100 80 120 M6 3 4
90 IM B5, IM B35, IMV1, IM V3 Flange FF 165 A 200 10 50 165 130 200 12 3.5 4
IM B14, IM V18, IM V19 Standard flange FT 115 C 140 - 50 115 95 140 M8 3 4
100 IM B5, IM B35, IMV1, IM V3 Flange FF 215 A 250 11 60 215 180 250 14.5 4 4
IM B14, IM V18, IM V19 Standard flange FT 130 C 160 - 60 130 110 160 M8 3.5 4
112 IM B5, IM B35, IMV1, IM V3 Flange FF 215 A 250 11 60 215 180 250 14.5 4 4
IM B14, IM V18, IM V19 Standard flange FT 130 C 160 - 60 130 110 160 M8 3.5 4
132 IM B5, IM B35, IMV1, IM V3 Flange FF 265 A 300 12 80 265 230 300 14.5 4 4
IM B14, IM V18, IM V19 Standard flange FT 165 C 200 - 80 165 130 200 M 10 3.5 4
160 IM B5, IM B35, IMV1, IM V3 Flange FF 300 A 350 13 110 300 250 350 18.5 5 4
IM B14, IM V18, IM V19 Standard flange FT 215 C 250 - 110 215 180 250 M 12 4 4
180 IM B5, IM B35, IMV1, IM V3 Flange FF 300 A 350 15 110 300 250 350 18.5 5 4
200 IM B5, IM B35, IMV1, IM V3 Flange FF 350 A 400 17 110 350 300 400 18.5 5 4
225 IM B5, IM B35, IMV1, IM V3 Flange FF 400 A 450 20 110/140 400 350 450 18.5 5 8
250 IM B5, IM B35, IMV1, IM V3 Flange FF 500 A 550 22 140 500 450 550 18.5 5 8
280 IM B5, IM B35, IMV1, IM V3 Flange FF 500 A 550 22 140 500 450 550 18.5 5 8
315 IM B5, IM B35, IMV1, IM V3 Flange FF 600 A 660 22 140/170 600 550 660 24 6 8
355 IM B5, IM B35, IMV1, IM V3 Flange FF 740 A 800 22 140/170 740 680 800 24 6 8

Chapter 5 · Dimensional drawings 69


© Siemens AG 2014

User parts
User parts selection 1LE0
Please note that an ordered quantity “1” will result in a package delivery containing pieces defined in column
“Pieces per ordered package”.
E.g. ordering “1” user parts package LMH:101358876 you will receive ten endshields drive-end B3.

IE Pieces per ordered User parts package


User parts Order quantity
class package Article No.
Frame size 80
Endshield drive-end B3 1 10 LMH:101358876
Flange drive-end B5 1 10 LMH:101358877
Flange drive-end B14 1 10 LMH:101358878
"V"-RING-M20 1 30 LMH:101358879
Fan 1 10 LMH:101358880
Fan cover 1 9 LMH:101359001
Canopy 1 6 LMH:101359002
Terminal board 1 5 LMH:101359003
Frame size 90
Endshield drive-end B3 1 12 LMH:101359004
Flange drive-end B5 1 10 LMH:101359005
Flange drive-end B14 1 12 LMH:101359006
"V"-RING-M25 1 30 LMH:101359007
Fan 1 10 LMH:101359008
Fan cover 1 9 LMH:101359009
Canopy 1 6 LMH:101359010
Terminal board 1 5 LMH:101359003
Frame size 100
Endshield drive-end B3 1 12 LMH:101359012
Flange drive-end B5 1 12 LMH:101359013
Flange drive-end B14 1 10 LMH:101359014
"V"-RING-M30 1 30 LMH:101359015
Fan 1 10 LMH:101359016
Fan cover 1 9 LMH:101359017
Canopy 1 6 LMH:101359018
Terminal board 1 5 LMH:101359019
IE2 Fan 1 10 LMH:101359020
Frame size 112
Endshield drive-end B3 1 14 LMH:101359021
Flange drive-end B5 1 12 LMH:101359022
Flange drive-end B14 1 12 LMH:101359023
"V"-RING-M30 1 30 LMH:101359015
Fan 1 10 LMH:101359016
Fan cover 1 9 LMH:101359026
Canopy 1 6 LMH:101359027
Terminal board 1 5 LMH:101359019
IE2 Endshield drive-end B3 1 14 LMH:101359029
IE2 Flange drive-end B5 1 12 LMH:101359030
IE2 Flange drive-end B14 1 12 LMH:101359031
Frame size 132
Endshield drive-end B3 1 4 LMH:101359032
Flange drive-end B5 1 4 LMH:101359033
Flange drive-end B14 1 4 LMH:101359034
"V"-RING-M40 1 30 LMH:101359035
Fan 1 10 LMH:101359036
Fan cover 1 9 LMH:101359037
Canopy 1 6 LMH:101359038
Terminal board 1 5 LMH:101359019
IE2 Endshield drive-end B3 1 4 LMH:101359040
IE2 Flange drive-end B5 1 4 LMH:101359041
IE2 Flange drive-end B14 1 4 LMH:101359042
IE2 Fan 1 10 LMH:101359043

70 Chapter 6 · User parts


© Siemens AG 2014

TIP
The parts required for simple modifications of the
flange type or replacing parts broken during bearing
change are readily available. The retrofitting of an
encoder is a common modification. In order to make
it easier, we offer the 1LE0 series with a non-drive end
shaft mounting facility and the metal fan cover which
has been prepared for modification.

IE Pieces per ordered User parts package


User parts Order quantity
class package Article No.
Frame size 160
Endshield drive-end B3 1 5 LMH:101359044
Flange drive-end B5 1 5 LMH:101359045
Flange drive-end B14 1 5 LMH:101359046
Shaft seal 1 30 LMH:101359047
Fan - 4-6-pole 1 10 LMH:101359048
Fan - 2-pole 1 10 LMH:101359049
Fan cover 1 9 LMH:101359050
Canopy 1 6 LMH:101359051
Terminal board 1 5 LMH:101359052
IE2 Endshield drive-end B3 1 5 LMH:101359053
IE2 Flange drive-end B5 1 5 LMH:101359054
IE2 Flange drive-end B14 1 5 LMH:101359055
IE2 Fan - 2-pole 1 10 LMH:101359056
Frame size 180
Endshield drive-end B3 1 5 LMH:101359057
Flange drive-end B5 1 5 LMH:101359058
Shaft seal 1 20 LMH:101359059
Fan - 2-pole 1 5 LMH:101359067
IE1 Fan - 4-6-pole 1 5 LMH:101359061
Fan cover 1 6 LMH:101359062
Canopy 1 4 LMH:101359063
Terminal board 1 5 LMH:101359052
IE2 Endshield drive-end B3 1 5 LMH:101359065
IE2 Flange drive-end B5 1 5 LMH:101359066
IE2 Fan 1 5 LMH:101359060
Frame size 200
Endshield drive-end B3 1 5 LMH:101359068
Flange drive-end B5 1 5 LMH:101359069
Shaft seal 1 20 LMH:101359070
Fan - 4-6-pole 1 5 LMH:101359071
Fan - 2-pole 1 5 LMH:101359072
Fan cover 1 6 LMH:101359073
Canopy 1 4 LMH:101359074
Terminal board 1 3 LMH:101359075
IE2 Endshield drive-end B3 1 5 LMH:101359076
IE2 Flange drive-end B5 1 5 LMH:101359077
IE2 Fan - 2-pole 1 5 LMH:101359078
Frame size 225
Endshield drive-end B3 1 3 LMH:101359079
Flange drive-end B5 1 3 LMH:101359080
Shaft seal 1 20 LMH:101359081
Fan - 2-pole 1 5 LMH:101359089
Fan - 4-6-pole 1 5 LMH:101359083
Fan cover 1 6 LMH:101359084
Canopy 1 4 LMH:101359085
Terminal board 1 3 LMH:101359086
IE2 Endshield drive-end B3 1 3 LMH:101359087
IE2 Flange drive-end B5 1 3 LMH:101359088
IE2 Fan - 4-6-pole 1 5 LMH:101359090

Chapter 6 · User parts 71


© Siemens AG 2014

User parts selection 1LE0


Please note that an ordered quantity “1” will result in a package delivery containing pieces defined in column
“Pieces per ordered package”.

IE Pieces per ordered User parts package


User parts Order quantity
class package Article No.
Frame size 250
Endshield drive-end B3 1 3 LMH:101359091
Flange drive-end B5 1 3 LMH:101359092
Shaft seal 1 20 LMH:101359093
Fan - 2-pole 1 5 LMH:101359094
Fan - 4-6-pole 1 5 LMH:101359095
Fan cover 1 6 LMH:101359096
Canopy 1 4 LMH:101359097
Terminal board 1 3 LMH:101359098
IE2 Endshield drive-end B3 1 3 LMH:101359099
IE2 Flange drive-end B5 1 3 LMH:101359100
IE2 Fan - 2-pole 1 5 LMH:101359078
Frame size 280
Shaft seal 1 20 LMH:101359102
Endshield drive-end B3 1 3 LMH:101359103
Flange drive-end B5 1 3 LMH:101359104
Fan - 2-pole 1 5 LMH:101359095
Fan - 4-6-pole 1 5 LMH:101359106
Fan cover 1 6 LMH:101359107
Canopy 1 4 LMH:101359108
Terminal board 1 3 LMH:101359098
IE2 Fan - 2-pole 1 5 LMH:101359110

72 Chapter 6 · User parts


© Siemens AG 2014

TIP
The parts required for simple modifications of the
flange type or replacing parts broken during bearing
change are readily available. The retrofitting of an
encoder is a common modification. In order to make
it easier, we offer the 1LE0 series with a non-drive end
shaft mounting facility and the metal fan cover which
has been prepared for modification.

IE Pieces per ordered User parts package


User parts Order quantity
class package Article No.
Frame size 315
Endshield drive-end B3 1 5 LMH:101359111
Flange drive-end B5 1 3 LMH:101359112
Shaft seal 1 10 LMH:101359113
Fan - 2-pole FS 315L 1 3 LMH:101359114
Fan - 2-pole FS 315 S/M 1 3 LMH:101359115
Fan - 4-6-pole FS 315L 1 3 LMH:101359116
Fan - 4-6-pole FS 315 S/M 1 3 LMH:101359117
IE1 Fan - 4-6-pole FS 315 L 1 3 LMH:101359118
Fan cover 1 4 LMH:101359119
Canopy 1 4 LMH:101359120
Terminal board 1 2 LMH:101359121
IE2 Fan - 2-pole FS 315 S/M 1 3 LMH:101359122
IE2 Fan - 4-pole FS 315 S/M 1 3 LMH:101359123
Frame size 355
Endshield drive-end B3 2-pole 1 4 LMH:101359124
Endshield drive-end B3 4-6-pole 1 4 LMH:101359125
Shaft seal 4-6-pole 1 10 LMH:101359126
Shaft seal 2-pole 1 10 LMH:101359113
Fan - 2-pole 1 3 LMH:101359115
Fan - 4-6-pole 1 3 LMH:101359117
Fan cover 1 4 LMH:101359130
Canopy 1 4 LMH:101359131
Terminal board 1 2 LMH:101359132

Note:
The Siemens warranty is valid for all motors which are tionality is a result of his work. We strongly recommend
originally supplied from the Siemens factory. an additional nameplate to be fixed to the cowl describ-
Any modification will result in the nameplate no longer ing those changes referencing the responsible workshop.
describing the physical build. Any such local adaptation That workshop carries the warranty for the motor and
is at the discretion of the user and the quality and func- the associated modification.

Chapter 6 · User parts 73


© Siemens AG 2014

User parts selection 1LA7/1LE1

Minimum
User parts Motor series Article No.
order quantity
Frame size 63
Shaft sealing ring 1 1LA7 –
Endshield drive-end B3 1 1LA7 XZM:21517134001001
Flange drive-end B5 1 1LA7 XZM:21517135501001
Flange drive-end B14 (small) 1 1LA7 XZM:21517136501001
Flange drive-end B14 (large) 1 1LA7 XZM:21517137501001
Fan cover 1) 1 1LA7 XZM:20747017001000
Impeller - fan plastic 1 1LA7 XZM:20000000300320
Impeller - fan aluminum 1 1LA7 XZM:27000914510050
Terminal board 1 1LA7 XZM:27000910420550
Fan cover with canopy 1 1LA7 XZM:27000809820150
Frame size 71
Shaft sealing ring 1 1LA7 –
Endshield drive-end B3 1 1LA7 XZM:27000915120450
Flange drive-end B5 1 1LA7 XZM:27000915122450
Flange drive-end B14 (small) 1 1LA7 XZM:27000915124650
Flange drive-end B14 (large) 1 1LA7 XZM:21517036501001
Fan cover 1) 1 1LA7 XZM:27000807421850
Impeller - fan plastic 1 1LA7 XZM:20000000300323
Impeller - fan aluminum 1 1LA7 XZM:20000000300304
Terminal board 1 1LA7 XZM:27000910420550
Canopy, screw-fixing 1 1LA7 XZM:27000809820150
Frame size 80
Shaft sealing ring 1 1LA7 –
Endshield drive-end B3 1 1LA7 XZM:27000915130050
Flange drive-end B5 1 1LA7 XZM:27000915132050
Flange drive-end B14 (small) 1 1LA7 XZM:27000915134050
Flange drive-end B14 (large) 1 1LA7 XZM:27000915133050
Fan cover 1) 1 1LA7 XZM:27000807430250
Fan cover 1) 1 1LE10 EWN:50748080200000
Impeller - fan plastic 1 1LA7 XZM:20000000300322
Impeller - fan plastic 1 1LE10 EWN:51458080220001
Impeller - fan aluminum 1 1LA7 XZM:20000000300309
Terminal board 1 1LA7 XZM:27000910420550
Canopy, screw-fixing 1 1LA7 XZM:27000809820150
Frame size 90
Shaft sealing ring 1 1LA7 –
Endshield drive-end B3 1 1LA7 XZM:27000915141050
Flange drive-end B5 1 1LA7 XZM:27000915142050
Flange drive-end B14 (small) 1 1LA7 XZM:27000915144050
Flange drive-end B14 (large) 1 1LA7 XZM:27000915143050
Fan cover 1) 1 1LA7 XZM:27000807440250
Fan cover 1) 1 1LE10 EWN:50748090200000
Impeller - fan plastic 1 1LA7 XZM:20000000300326
Impeller - fan plastic 1 1LE10 EWN:51458090220001
Impeller - fan aluminum 1 1LA7 XZM:20000000300308
Terminal board 1 1LA7 XZM:27000910420550
Canopy, screw-fixing 1 1LA7 XZM:27000809850050

– Not available
1) Plastic fan cover for 1LA7 and 1LE10 series, sheet metal fan cover for 1LE0 series.

74 Chapter 6 · User parts


© Siemens AG 2014

TIP
The parts required for simple modifications of the
flange type or replacing parts broken during bearing
change are readily available. The retrofitting of an
encoder is a common modification. In order to make
it easier, we offer the 1LE0 series with a non-drive end
shaft mounting facility and the metal fan cover which
has been prepared for modification.

Minimum
User parts Motor series Article No.
order quantity
Frame size 100
Shaft sealing ring 1 1LE10 XZM:50300100301001
Endshield drive-end B3 1 1LE10 XZM:27000812950890
Flange drive-end B5 1 1LE10 XZM:27000812952590
Flange drive-end B14 1 1LE10 XZM:27000812954790
Fan cover 1) 1 1LE10 XZM:50748100200000
Impeller - fan 2-pole 1 1LE10 XZM:51458112220001
Impeller - fan 4-pole 1 1LE10 XZM:51458112220000
Impeller - fan 6-pole 1 1LE10 XZM:51458100240000
Terminal board 1 1LE10 XZM:27000910450350
Fan cover with canopy 1 1LE10 XZM:50318100310000
Frame size 112
Shaft sealing ring 1 1LE10 XZM:50300100301001
Endshield drive-end B3 1 1LE10 XZM:27000812960690
Flange drive-end B5 1 1LE10 XZM:27000812962790
Flange drive-end B14 1 1LE10 XZM:27000812964590
Fan cover 1) 1 1LE10 XZM:50748112200000
Impeller - fan 2-pole 1 1LE10 XZM:51458112220000
Impeller - fan 4/6-pole 1 1LE10 XZM:51458112240000
Terminal board 1 1LE10 XZM:27000910450350
Fan cover with canopy 1 1LE10 XZM:27000903160390
Frame size 132
Shaft sealing ring 1 1LE10 XZM:50300132301001
Endshield drive-end B3 1 1LE10 XZM:27000812970390
Flange drive-end B5 1 1LE10 XZM:27000812972990
Flange drive-end B14 1 1LE10 XZM:27000812974092
Fan cover 1) 1 1LE10 XZM:50748132200500
Impeller - fan 2-pole 1 1LE10 XZM:51458132220000
Impeller - fan 4/6-pole 1 1LE10 XZM:51458132240000
Terminal board 1 1LE10 XZM:27000910470350
Fan cover with canopy 1 1LE10 XZM:27000903170092
Frame size 160
Shaft sealing ring 1 1LE10 XZM:50300160301001
Endshield drive-end B3 1 1LE10 XZM:27000812981290
Flange drive-end B5 1 1LE10 XZM:27000812982192
Flange drive-end B14 1 1LE10 XZM:27000812984192
Fan cover 1) 1 1LE10 XZM:50748160200500
Impeller - fan 2-pole 1 1LE10 XZM:51458160220000
Impeller - fan 4-pole IE2 1 1LE10 XZM:51458160240001
Impeller - fan 6-pole IE2 / 4/6 pole IE1 1 1LE10 XZM:51458160240000
Terminal board 1 1LE10 XZM:27000910480346
Fan cover with canopy 1 1LE10 XZM:27000903180190

1) Plastic fan cover for 1LA7 and 1LE10 series, sheet metal fan cover for 1LE0 series.

Note:
The Siemens warranty is valid for all motors which are tionality is a result of his work. We strongly recommend
originally supplied from the Siemens factory. an additional nameplate to be fixed to the cowl describ-
Any modification will result in the nameplate no longer ing those changes referencing the responsible workshop.
describing the physical build. Any such local adaptation That workshop carries the warranty for the motor and
is at the discretion of the user and the quality and func- the associated modification.

Chapter 6 · User parts 75


© Siemens AG 2014

Handling and storage


When lifting the motors, always use the lifting eyes The service life of the motor can be considerably reduced if
provided. Prior to lifting the motor make sure that the the storage period extends beyond 2 years in environments
lifting eyes are installed correctly and tightened. with high moisture and dirt. If necessary, the insulation
Never lift a motor using the rotor shaft and fan cowling. resistance of the winding could be measured to determine
In addition, care must be taken during lifting and lowering the health of the motor prior to installation and start-up.
of the motor to avoid any shocks or vibrations which can
result in bearing damages. Machined surfaces (flange, DE rotor shaft) are treated at
the factory with an anti corrosive agent to prevent rusting.
It is recommended that all motor be stored in a dry, However, these surfaces should be retreated during
dust free environment and free of excessive vibrations. storage as deemed necessary. It is recommended that
the motor shaft is rotated by hand on a frequent basis to
If the DE and NDE bearings are of the sealed types, it ensure even grease distribution.
is recommended that they are replaced if storage has
exceeded 2 years from date of motor manufacture. If the
motors have the regreasable bearings, then the recom-
mendation is to replace the grease after 2 years of storage.

Certificates
ISO 9001 ISO 14001
Quality Management System Certificate Environmental Management System Certificate

76 Chapter 6 · User parts


© Siemens AG 2014

Notes

Chapter 6 · User parts 77


© Siemens AG 2014

Notes

78 Chapter 6 · User parts


© Siemens AG 2014

Notes

Chapter 6 · User parts 79


© Siemens AG 2014

Siemens AG Subject to change without prior notice The information provided in this brochure contains merely general des-
Industry Sector E.9115.63.LDT criptions or characteristics of performance which in case of actual use do
not always apply as described or which may change as a result of further
Drive Technologies Division BR 0714 80 En
development of the products. An obligation to provide the respective
Large Drives © Siemens AG 2014 characteristics shall only exist if expressly agreed in the terms of contract.
Postfach 48 48 Availability and technical specifications are subject to change without notice.
90026 NÜRNBERG All product designations may be trademarks or product names of Siemens AG
GERMANY or supplier companies whose use by third parties for their own purposes
could violate the rights of the owners.

www.siemens.com/motors