Serie 52
Serie 52
Serie 52
Replaces: 12.2016
Features Contents
▶ Variable pump with axial piston rotary group in Type code series 52 and 53 2
swashplate design for hydrostatic drives in open circuit. Hydraulic fluids 7
▶ Flow is proportional to drive speed and displacement. Working pressure range 9
▶ The flow can be infinitely varied by adjusting the Technical data 10
swashplate angle. DR – Pressure controller 14
▶ Stable bearing for long service life DRG – Pressure controller, remotely controlled 15
▶ High permissible drive speed DRF (DFR) / DRS (DFR1).... – press. flow controller 16
▶ Favorable power-to-weight ratio – compact dimensions LA... – Pressure, flow and power controller 18
▶ Low noise LA... – Variations 19
▶ Excellent suction characteristics ED – Electrohydraulic pressure control 20
▶ Electro-hydraulic pressure control ER – Electrohydraulic pressure control 22
▶ Power control EP – Electro-proportional control 23
▶ Electro-proportional swivel angle control EK – Electro-proportional control with contr. cut-off 24
▶ Short control response times EP(K).DF / EP(K).DS / .. – with press. flow controller 25
EP.ED / EK.ED – with elec.-hydr. pressure control 26
Dimensions, size 10 to 100 27
Dimensions, through drive 69
Overview of mounting options 73
Combination pumps A10VO + A10VO 74
Connector for solenoids 75
Installation instructions 76
Project planning notes 79
Safety instructions 80
01 02 03 04 05 06 07 08 09 10 11 12
A10V(S) O / 52 – V
Operating mode
02 Pump, open circuit O
Size (NG)
03 Geometric displacement, see table of values on page 10 10 28 45 60 85
Control device
04 Pressure controller hydraulic ● ● ● ● ● DR
with flow controller hydraulic X-T open ● ● ● ● ● DFR
X-T plugged with flushing function ● ● ● ● ● DFR1
without flushing function – ● ● ● ● DRSC
with pressure cut-off hydraulic remote controlled ● ● ● ● ● DRG
electric negative control U = 12 V – ● ● ● ● ED71
U = 24 V – ● ● ● ● ED72
electric positive control U = 12 V – ● ● ● ● ER71
U = 24 V – ● ● ● ● ER72
Differential pressure control electric control (negative control) – ○ ○ ○ ● EF..1)
Series 10 28 45 60 85
05 Series 5, index 2 ● ● ● ● ● 52
Direction of rotation
06 Viewed on drive shaft clockwise R
counter-clockwise L
Sealing material
07 FKM (fluoroelastomer) V
Drive shaft
08 Splined shaft Standard shaft ● ● ● ● ● S
ISO 3019-1 similar to shaft "S" however for higher torque – ● ● ● ● R
reduced diameter, limited suitability for through drive ● ● ● ● ● U
similar to shaft "U", however for higher torque
only conditionally suitable for mounting with through drive. – ● ● ● ● W
For mounting options, see page 73
Parallel keyed shaft ISO 3019-1 limited suitability for through drive ● ● ● ● ● K
Tapered with Woodruff key – ● ● ● ● C
Mounting flange
09 ISO 3019-1 (SAE) 2-hole ● ● ● ● ● C
4-hole – – – ● – D
01 02 03 04 05 06 07 08 09 10 11 12
A10V(S) O / 52 – V
Working port 10 28 45 60 85
10 SAE flange ports rear not for through drive – ● ● ● ● 61
Fastening thread
UNC laterally opposite for through drive – ● ● ● ● 62
Notice
▶ Observe the general project planning notes on
page 79 and the project planning notes regarding
each control device.
▶ In addition to the type code, please specify the rel-
evant technical data.
01 02 03 04 05 06 07 08 09 10 11 12
A10V O / 53 – V
Operating mode
02 Pump, open circuit O
Size (NG)
03 Geometric displacement, see table of values on page 10 18 28 45 63 72 85 100
Control device
04 Pressure controller hydraulic ● ● ● ● ● ● ● DR
with flow controller hydraulic X-T open ● ● ● ● ● ● ● DRF
X-T plugged with flushing function ● ● ● ● ● ● ● DRS
without flushing function ● ● ● ● ● ● ● DRSC
with pressure cut-off hydraulic remote controlled ● ● ● ● ● ● ● DRG
electric negative control U = 12 V ● ● ● ● ● ● ● ED71
U = 24 V ● ● ● ● ● ● ● ED72
electric positive control U = 12 V ● ● ● ● ● ● ● ER71
U = 24 V ● ● ● ● ● ● ● ER72
Differential pressure control electric control (negative control) ○ ○ ○ ○ ○ ● ● EF..1)
Power control with hydraulic Beginning of control from 145 to 510 psi
● ● ● ● ● ● ● LA5D
pressure cut-off (10 to 35 bar)
520 to 1015 psi
● ● ● ● ● ● ● LA6D
(36 to 70 bar)
1030 to 1520 psi
● ● ● ● ● ● ● LA7D
(71 to 105 bar)
1535 to 2030 psi
● ● ● ● ● ● ● LA8D
(106 to 140 bar)
2045 to 3335 psi
● ● ● ● ● ● ● LA9D
(141 to 230 bar)
remote controlled hydraulic Beginning of control see LA.D ● ● ● ● ● ● ● LA.DG
Flow control hydraulic Beginning of control see LA.D
X-T plugged with flushing ● ● ● ● ● ● ● LA.DS
function
hydraulic Beginning of control see LA.D
without flushing ● ● ● ● ● ● ● LA.DC
function
Differential Beginning of control see LA.D
○ ○ ○ ○ ○ ● ● LA.EF1)
pressure control1)
Notice
▶ Observe the project planning notes regarding each
1) See data sheet 92709 for precise specification control device
01 02 03 04 05 06 07 08 09 10 11 12
A10V O / 53 – V
18 28 45 63 72 85 100
04 Electro-proportional control positive control
with pressure control U = 12 V ● ● ● ● ● ● ● EP1D
U = 24 V ● ● ● ● ● ● ● EP2D
with pressure and flow control X-T open U = 12 V ● ● ● ● ● ● ● EP1DF
(load-sensing) U = 24 V ● ● ● ● ● ● ● EP2DF
with pressure and flow control X-T plugged U = 12 V ● ● ● ● ● ● ● EP1DS
(load-sensing) U = 24 V ● ● ● ● ● ● ● EP2DS
with electrohydraulic U = 12 V ● ● ● ● ● ● ● EP1ED
Pressure control U = 24 V ● ● ● ● ● ● ● EP2ED
Electro-proportional control positive control
with pressure control U = 12 V ● ● ● ● ● ● ● EK1D
U = 24 V ● ● ● ● ● ● ● EK2D
Pressure and flow control with X-T open U = 12 V ● ● ● ● ● ● ● EK1DF
controller cut-off (load sensing) U = 24 V ● ● ● ● ● ● ● EK2DF
Pressure and flow control with X-T plugged U = 12 V ● ● ● ● ● ● ● EK1DS
controller cut-off (load sensing) U = 24 V ● ● ● ● ● ● ● EK2DS
electrohydraulic pressure control with U = 12 V ● ● ● ● ● ● ● EK1ED
controller cut-off U = 24 V ● ● ● ● ● ● ● EK2ED
Series
05 Series 5, index 3 ● ● ● ● ● ● ● 53
Direction of rotation
06 Viewed on drive shaft clockwise R
counter-clockwise L
Sealing material
07 FKM (fluoroelastomer) V
Drive shaft
08 Splined shaft Standard shaft ● ● ● ● ● ● ● S
ISO 3019-1 similar to shaft "S" however for higher torque ● ● ● ● ● ● ● R
reduced diameter, limited suitability for through drive ● ● ● ● ● ● ● U
similar to shaft "U", however for higher torque
only conditionally suitable for mounting with through drive. – – ● ● ● ● ● W
For mounting options, see page 73
Parallel keyed shaft ISO 3019-1 limited suitability for through drive ● ● ● ● ● ● ● K
Mounting flange
09 ISO 3019-1 (SAE) 2-hole ● ● ● ● ● ● ● C
4-hole – – – ● ● ● ● D
Working port
10 SAE flange ports rear not for through drive ● ● ● ● ● ● ● 61
Fastening thread UNC
laterally opposite for through drive ● ● ● ● ● ● ● 62
01 02 03 04 05 06 07 08 09 10 11 12
A10V O / 53 – V
Notice
▶ Note the project planning notes on page 79.
▶ In addition to the type code, please specify the rel-
evant technical data when placing your order.
Hydraulic fluids
The A10VO variable pump is designed for operation with Selection of hydraulic fluid
HLP mineral oil according to DIN 51524. Bosch Rexroth evaluates hydraulic fluids on the basis of
See the following data sheets for application instructions the Fluid Rating according to the technical
and requirements for hydraulic fluids before the start of data sheet 90235.
project planning: Hydraulic fluids with positive evaluation in the Fluid
▶ 90220: Hydraulic fluids based on mineral oils and Rating are provided in the following technical data sheet:
related hydrocarbons ▶ 90245: Bosch Rexroth Fluid Rating List for Rexroth
▶ 90221: Environmentally acceptable hydraulic fluids hydraulic components (pumps and motors)
Warm-up phase ν = 1600 … 400 cSt (mm²/s) t ≤ 15 min, p ≤ 0.7 × pnom and n ≤ 0.5 × nnom
Continuous ν = 400 … 10 cSt (mm²/s)1) FKM ϑ ≤ +230°F Measured at port Lx
operation (+110 °C)
νopt = 36 … 16 cSt (mm²/s) Optimal operating viscosity and efficiency range
Short-term νmin = 10 … 7 cSt (mm²/s) FKM t ≤ 3 min, p ≤ 0.3 × pnom, measured at port Lx
operation
▼ Selection diagram
200
VG 68
VG 46
VG
VG 32
VG 2
10
2
100
0
Continuous operation 60
40
36
νopt
20
16
10
Minimum permissible viscosity for short-term operation
7
−40 −13 14 32 50 86 104 122 158 195 240
(−40) (−25) (−10) (0) (10) (30)(40)(50) (70) (90) (115)
Temperature ϑ [°F (°C)]
1) This corresponds, for example on the VG 46, to a temperature 2) If the temperature at extreme operating parameters cannot be
range of +39 °F to 113 °F (+4 °C to +85 °C) adhered to, please contact us.
(see selection diagram) 3) For applications in the low-temperature range, please contact us.
1.2
24 (1.6)
Minimum pressure (high-pressure side)
Inlet pressure pabs psi (bar)
20 (1.4)
1.1
Time t
Speed n / nnom
17 (1.2)
Total operating period = t1 + t2 + ... + tn
1.0 15 (1.0)
▼ Rate of pressure change RA max
13 (0.9)
pnom
0.9 12 (0.8) ∆t
0.7 0.8 0.9 1.0
Pressure p
Displacement Vg/Vgmax
∆p
Time t
Technical data
Size NG 10 18 28 45 60 63 72 85 100
Displacement, geometric, per Vg 3
in 0.64 1.10 1.75 2.75 3.66 3.84 4.39 5.18 6.10
revolution max (cm3) (10.5) (18) (28) (45) (60) (63) (72) (85) (100)
Maximum at Vg max nnom rpm 3600 3300 3000 26002) 2700 2600 2600 2500 2300
rotational at Vg <Vg max nmax rpm 4320 3960 3600 3120 3140 3140 3140 3000 2500
speed1)
perm
1) The values are applicable: 3) The data are valid for values between the minimum required
– At an abs. pressure pabs = 15 psi (1 bar) at the suction port S and maximum permissible rotational speed. It applies for external
‒ for the optimum viscosity range from νopt = 36 to 16 cSt stimuli (e.g. diesel engine 2 to 8 times rotary frequency, cardan
(mm²/s) shaft twice the rotary frequency). The limit value is only valid for
‒ with hydraulic fluid on the basis of mineral oils a single pump. The load capacity of the connection parts must be
2) See diagram on page 9 at speed increase up to nmax perm. considered.
4) On Request
Key
Vg Displacement per revolution [in3 (cm3)]
Δp Differential pressure [psi (bar)]
n Rotational speed [rpm]
ηv Volumetric efficiency
ηhm Hydraulic-mechanical efficiency
ηt Total efficiency (ηt = ηv × ηhm)
Notice
▶ Theoretical values, without efficiency and tolerances;
values rounded
▶ Operation above the maximum values or below the
minimum values may result in a loss of function,
a reduced service life or in the destruction of the axial
piston unit. Bosch Rexroth recommends checking the
load by means of experiment or calculation /
simulation and comparison with the permissible
values.
Axial force maximum + Fax max lbf 90 157 225 337 450 337 675 675
Fax –
+
(N) (400) (700) (1000) (1500) (2000) (1500) (3000) (3000)
Notice
▶ The values given are maximum values and do not
apply to continuous operation. All loads of the drive
shaft reduce the bearing service life.
▼ Distribution of torques
M1 M2
ME
MD
DR – Pressure controller
▼ Characteristic curve DR
max
Hysteresis/pressure increase Δp
3600
(250)
Working pressure pB [psi (bar)]
L2 S
Controller data
Size 10 18 28 45 60 72 85 100
63
Pressure Δp [psi 87 87 87 87 115 115 175 200
increase (bar)] (6) (6) (6) (6) (8) (8) (12) (14)
Hysteresis Δp [psi maximum 45 (3)
and (bar)]
Repeat
510 accuracy
(35)
Pilot fluid gpm maximum approx. 0.8 (3)
con- (l/min)
qv min Flow qV qv max sumption
For the remote controlled pressure controller, the LS ▼ Circuit diagram DRG
3600 increase (bar)] (6) (6) (6) (6) (8) (8) (12) (14)
Hysteresis/pressure increase Δp
(250)
Hysteresis Δp maximum 45 (3)
and [bar]
Repeat
accuracy
Pilot fluid gpm maximum approx. 1.2 (4.5)
con- (l/min)
sumption
Standby2)
▼ Characteristic curve DRF (DFR) / DRS (DFR1) / DRSC Plugged at DRS (DFR1) / DRSC valve
X
max
3600
Hysteresis/pressure increase Δp
2 1
(250)
Working pressure pB [psi (bar)]
L L1 B
Stand by2)
0
qv min qv max
Flow qV
qV max
Hysteresis/pressure increase ΔqV
Controller data
▶ DR pressure controller data see page 14
▶ Maximum flow deviation measured at drive
speed n = 1500 rpm.
Size 10 18 28 45 60 72 85 100
63
Flow deviation Δq vmax [gpm (l/min)] 0.13 (0.5) 0.24 (0.9) 0.26 (1.0) 0.48 (1.8) 0.66 (2.5) 0.66 (2.5) 0.83 (3.1) 0.83 (3.1)
Hysteresis; Δp [psi (bar)] maximum 45 (3)
Repeat accuracy
Pilot fluid gpm (l/min) maximum approx. 0.8 to 0.2 (3 to 4.5) (DRF (DFR))
consumption maximum approx. 0.8 (3) (DRS (DFR1) / DRSC)
Pressure controller equipped as DR(G), When ordering please state the power characteristics to
see page 14 (15). be set ex works in plain text, e.g. 27 HP (20 kW) at
Equipment of the flow controller like DRS (DFR1), 1500 rpm.
see page 16. Controller data
In order to achieve a constant drive torque with varying ▶ Pressure controller DR see page 14.
operating pressures, the swivel angle and with it the ▶ Pressure and flow controller DR see page 16.
volume flow from the axial piston pump is varied so that ▶ See data sheet 92709 for electric override LA.EF
the product of flow and pressure remains constant. ▶ Pilot fluid consumption max. approx. 1.45 gpm
Flow control is possible below the power control curve. (5.5 l/min).
Beginning of Torque M [lb-ft (Nm)] for size Order
control code
psi (bar) 18 28 45 63 72 85 100
145 to 510 2.80 – 8.92 4.4 – 14 7.4 – 22.1 11 – 32 12.5 – 36.3 15 – 42 18 – 49.5 LA5
(10 to 35) (3.8 – 12.1) (6 – 19) (10 – 30) (15 – 43) (17 – 49.2) (20 – 57) (24 – 68)
520 to 1015 8.92 – 17.2 14 – 26.5 22.2 – 43.5 32 – 61 36.4 – 69.9 42 – 83 49.5 – 97.1 LA6
(36 to 70) (12.2 – 23.3) (19.1 – 36) (30.1 – 59) (43.1 – 83) (49.3 – 94.9) (57.1 – 112) (68.1 – 132)
1030 to 1520 17.2 –24.9 26.6 – 38.4 43.6 – 62 61 – 88 70 – 100.3 83 – 118 97.1 – 139.4 LA7
(71 to 105) (23.4 – 33.7) (36.1 – 52) (59.1 – 84) (83.1 – 119) (95.0 – 136.0) (112.1 – 160) (132.1 – 189)
1535 to 2030 24.9 –33.2 38.4 – 51.6 62 – 83 88 – 116 100.4 – 132.3 118 – 156 139.4 – 183.6 LA8
(106 to 140) (33.8 – 45) (52.1 – 70) (84.1 – 112) (119.1 – 157) (136.1 – 179.4) (160.1 – 212) (189.1 – 249)
2045 to 3335 33.2 – 55.2 51.7 – 86.3 83 – 139 116 – 195 132.4 – 222.5 156 – 263 183.3 – 309 LA9
(141 – 230) (45.1 – 74.8) (70.1 – 117) (112.1 – 189) (157.1 – 264) (179.5 – 301.7) (212.1 – 357) (249.1 – 419)
4350 (300)
Working pressure pB [psi (bar)]
3600 (250)
LA9
2900 (200)
LA8
2200 (150)
LA7
1450 (100)
LA6
725 (50)
LA5
0 (0)
0 Flow qV [%] 100
∆qV
LA9
Torque M
LA8
LA7
LA6
LA5
LA... – Variations
X X
L L1 B
L L1 B
L2 S
L2 S
X
X
L L1 B
L2 S
3600 (250)
Δp max < 60 psi (4 bar)
Setting range
(de-energized)
2000 (140) L2 S
Notice!
With ED71, de-energized operating condition
(jump from 100 to 0 mA) results in a pressure increase
of the maximum pressure of 60 to 75 psi (4 to 5 bar).
With ED72, de-energized operating condition
(jump from 50 to 0 mA) results in a pressure increase of
the maximum pressure of 60 to 75 psi (4 to 5 bar).
3600 (250)
Maximum adjustable
control pressure
2200 (150)
L2 S
725 (50) Minimum adjustable
20 (14) control pressure Technical data, solenoids ER71 ER72
0
0 1 Voltage 12 V (±20%) 24 V (±20%)
Current I/I max
Control current
▶ Hysteresis static current-pressure characteristic Start of control at pmin 100 mA 50 mA
curve < 45 psi (3 bar). End of control at pmax 1200 mA 600 mA
Current limit 1.54 A 0.77 A
▼ Flow-pressure characteristic curve
Nominal resistance 5.5 Ω 22.7 Ω
(at 68 °F (20 °C))
Maximum working pressure p [psi (bar)]
3600 (250)
Hysteresis/pressure increase
Setting range
EP – Electro-proportional control
0 0.5 1.0
Displacement [%]
Vg min Vg max
Variant EK... is based completely on the variant EP... ▼ Circuit diagram EK.D
In Vg max position, the spring force of the return spring Start of control at Vg min 400 mA 200 mA
is maximum. To overcome the force of this spring, End of control at Vg max 1200 mA 600 mA
the solenoid must be subjected to excessive current (Ires). Dither frequency 100 Hz 100 Hz
Recommended amplitude 240 mA 120 mA
▼ Characteristic curve EK1/2 Peak to peak1)
Current limit 1.54 A 0.77 A
1400 Nominal resistance 5.5 Ω 22.7 Ω
(at 68 °F (20 °C))
Ires
1200 Duty cycle 100% 100%
Control current I [ mA]
Ioff
Notice!
0 0.5 1.0
We recommend the valve with flushing function for the
Displacement [%]
EK.D control variant. Please contact us.
▶ Hysteresis static current-displacement
characteristic curve < 5 %.
▶ For changes in current, ramp times of > 200 ms must be
observed
1) ΔI = 44% of the current difference within the control range,
regardless of the mean value of the current
electro-proportional control.
The pressure control regulates the pump displacement
X
infinitely varied back to Vg min after the set pressure
command value has been reached. 1
This function is super-imposed on the EP or EK control, i.e.
the control-current dependent EP or EK function is
executed below the pressure command value.
For the setting range of the pressure flow controller,
see page 14 to 16.
With all controller combinations, the Vg reduction has
priority. L L1 B
L L1 B
X
L L1 B
L2 S
L2 S
L L1 B
L2 S
Dimensions, size 10
6)
(5
0.25 (6.4)
20
L
2.
Flange
4 5°
ISO 3019-1
0. )
35
(ø 82.55 -0.054 )
0.43
(11)
(9
DIA 3.250
3.248
45
0
2.11 (53.5)
2.30 (58.5)
L1
▼ View Y ▼ View Y
Valve mounting Valve mounting for
for clockwise counter-clockwise
rotation rotation
S B
B S
1.13 1.13 1.13 1.13
(28.6) (28.6) (28.6)(28.6)
2.00 (51) 2.00 (51) 2.00 (51) 2.00 (51)
▼ Splined shaft 3/4 in (19-4, ISO 3019-1) ▼ Splined shaft 5/8 in (16-4, ISO 3019-1)
1)
S ‒ 11T 16/32DP U ‒ 9T 16/32DP1)
1.18 (30)
0.94
0.55 (14) (23.8)
1/4-20UNC-2B2)
0.20 (5)
DIA 0.87
DIA 0.87
(ø22)
(ø22)
Centering3) 0.62
0.87 (22) R 0.12 × 0.26 (15.8)
DIN 332
1.50 (38) 1.25 (31.8)
DIA 0.750
(21.1 +0.05
-0.1
DIA 0.87
0.827
0.833
(Ø22)
Centering3)
R 0.12 × 0.26 1.61 (41)
DIN 332
1) Involute spline according to ANSI B92.1a, 30° pressure angle, 5) The countersink may be deeper than specified in the standard.
flat root, side fit, tolerance class 5 6) Depending on the installation position, L or L1 must be connected
2) Thread according to ASME B1.1 (also see installation instructions starting on page 76).
3) Coupling axially secured, e.g. with a clamp coupling or radially 7) O = Must be connected (plugged on delivery)
mounted clamping screw X = Plugged (in normal operation)
4) Depending on the application, momentary pressure peaks can
occur.
Keep this in mind when selecting measuring devices and fittings.
▼ DRG – Pressure controller, remotely controlled (SAE)1) ▼ DFR/DFR1 – Pressure, flow controller (SAE)1)
4.02 (102)
4.02 (102)
3.74 (95)
3.74 (95)
L1 L1
7.09 (180) 7.09 (180)
Dimensions, size 18
4.80 (122)
Flange
ISO 3019-1 L
2.83 (72)
0.
09
L 45°
(2
(Ø82.55- 00.054 )
.5
3.250
DIA 3.248
)
5)
5)
1.
1.
(6
X
(6
42
42
0.43 (11)
2.48 (63)
2.
2.
45°
L2
(47.6)
(Ø32)
1.87
S B
1.19
▼ Port plate 62 (30.2) 0.87 (22.2)
Detail Z
1.26 1.30
(32) (33)
DIA 0.79 (Ø20)
3.27 (83)
1.87 (47.6)
L1
Flange B 0.87
ISO 3019-1 (22.2)
L
(Ø82.55 - 00.054 )
2.31 (58.7)
DIA 3.250
3.248
DIA 1.26
(Ø32)
Y Z
S
1.19 (30.2)
5.67 (144) 2.22 (56.5) 2.22 (56.5)
6.70 (170)
▼ Splined shaft 3/4 in (19-4, ISO 3019-1) ▼ Splined shaft 3/4 in (similar to ISO 3019-1)
1)
S ‒ 11T 16/32DP R ‒ 11T 16/32DP1)2)
1.18 (30)
0.55 (14)
1/4-20UNC-2B4)5)
0.20 (5)
DIA 0.87
Ø22
DIA 0.87
(Ø22)
Centering4)
0.87 (22)
R 0.12 × 6.7 Usable 0.83 (21)
DIN 332 spline length
1.50 (38) 1.50 (38)
▼ Splined shaft 5/8 in (16-4, ISO 3019-1) ▼ Parallel keyed shaft DIN 6885
U ‒ 9T 16/32DP1) K ‒ 19-1
Shaft key width
0.188
0.94
-0.004 )
0.749 (ø19.05+0.009
(23.8) 1.30 (33) 0.187
(4.76+0.025)
0.1 1.03 (26.1)
(2.5)
DIA 0.87
(ø22)
DIA 0.750
(21.1 +0.05
-0.1
DIA 0.87
0.827
0.833
(Ø22)
Centering4) 0.62
R 0.12 × 6.7 (15.8)
DIN 332 Centering4)
R 0.12 × 6.7 1.61 (41)
1.25 (31.8) DIN 332
1) Involute spline according to ANSI B92.1a, 30° pressure angle, 6) The countersink may be deeper than specified in the standard.
flat root, side fit, tolerance class 5 7) Depending on the installation position, L, L1 or L2 must be
2) Splines according to ANSI B92.1a, spline runout is a deviation from connected (also see installation instructions starting on
standard ISO 3019-1. page 76).
3) Thread according to ASME B1.1 8) O = Must be connected (plugged on delivery)
4) Coupling axially secured, e.g. with a clamp coupling or radially X = Plugged (in normal operation)
mounted clamping screw
5) Depending on the application, momentary pressure peaks can
occur.
Keep this in mind when selecting measuring devices and fittings.
▼ DRG – Pressure controller, remotely controlled, series 53 ▼ EP.D. / EK.D. – Electro-proportional control, series 53
4.33 (110)
4.17 (106)
L L
4.80 (122)
S
S L2 L2
▼ DRF/DRS/DRSC – Pressure and flow controller, series 53 ▼ EP.ED. / EK.ED. – Electro-prop. control, series 53
X
4.17 (106)
4.33 (110)
L
4.80 (122)
L2
S L2
▼ LA.D. – Pressure, flow and power controller, series 53 ▼ ED7. / ER7. – Electro-prop. Pressure control, series 53
L L
L2 S L2
S
Dimensions, size 28
▼ Port plate 61
3.54 (90)
4.88 (124)
Flange
ISO 3019-1 L
L
(14.3)
)
0.56
(ø101.6 -0.054
DIA 4.000
3.998
69
0
2.64 (67)
2.44 (62)
1.06 (27) L1 5.75 (146)
0.31 (7.9) 6.69 (170) 6.77 (172)
max. 8.27 (210)
View X1)
▼ Port plate 62
max. 8.27 (210)
3.54 (90)
0.47 (12)
0.37 (9.5)
0.79 (ø20)
0.25 (6.3)
Flange
2.31 (58.7)
1.26 (ø32)
ISO 3019-1
(47.6)
1.87
L
)
2.31 (58.7)
(ø101.6 -0.054
B
DIA 4.000
3.998
S
(ø32)
Y
0
1.26
1.19 0.87
(30.2) (22.2)
S 1.39 1.39
0.79 (ø20)
B 0.87
(22.2)
Z
S B
S B
Dimensions, size 28
▼ Port plate 61
max. 8.27 (210)
3.54 (90)
0.37 (9.5) 1.14 (29) L1
0.25 (6.3)
L
L1
Flange
5.12 (130)
0. )
12
ISO 3019-1
(3
0.56 (14.3)
3.23 (82)
L
45°
(⌀101.6-0.054)
(7 .91
3.998
DIA 4.000
0
4)
2
X
(7 .91
2.95 (75)
45°
4)
2
L2
0.47 (12)
0. )
12
5.75 (146)
(3
3.54 (90) 6.77 (172)
6.69 (170)
View X1)
0.79 (⌀20)
2.31 (58.7)
(47.6)
(⌀32)
1.87
1.26
S B
▼ Port plate 62
1.19 (30.2) 0.87 (22.2)
max. 8.27 (210) 1.30 1.30
3.54 (90)
View Z (33) (33)
B
0.37 (9.5) 1.14 (29)
0.25 (6.3)
View Y1)
(47.6)
1.87
L1 X
L
Flange
0.79 ⌀20)
ISO 3019-1
0.87
(22.2)
(⌀101.6-0.054)
3.998
DIA 4.000
0
(58.7)
(⌀32)
2.31
1.26
Y Z
B
S
▼ Splined shaft 7/8 in (22-4, ISO 3019-1) ▼ Splined shaft 7/8 in (similar to ISO 3019-1)
1)
S ‒ 13T 16/32DP R ‒ 13T 16/32DP1)2)
1.30 (33.1)
0.63 0.63 (16)
(16)
1/4-20UNC-2B3)
1/4-20UNC-2B3) 0.20 (5)
0.20(5)
▼ Splined shaft 3/4 in (19-4, ISO 3019-1) ▼ Splined shaft 3/4 in (similar to ISO 3019-1)
1)
U ‒ 11T 16/32DP W ‒ 11T 16/32DP1)2)
1.18 (30)
0.55 0.55 (14)
1/4-20UNC-2B3)
(14) 0.20
1/4-20UNC-2B3)
0.20 (5) (5)
▼ Parallel keyed shaft (ISO 3019-1) ▼ Tapered with woodruff key (ISO 3019-1)
K ‒ 22-1 C
0.8742 (ø22.225 -0.02 )
1.31 (33.3)
1/4-20UNC-2B 3)
A
)
(Ø21.774+0.006
+0.025
0.8575
DIA 0.8570
0.98 (Ø25)
DIA0.8750
(25 -0.2 )
0.250(6.35
0.251
0.130
0.16 (Ø4) B
0.118 1.10
0.110 (3 -0.2 ) (28)
Ports Port plate 61 and 62 Standard Size pmax [psi (bar)]1) State5)
B Working port (standard pressure series) ISO 6162-1 3/4 in 4550 (315) O
Fastening thread ASME B1.1 3/8-16UNC-2B; 0.75 (19) deep
S Suction port (standard pressure series) ISO 6162-1 1 1/4 in 75 (5) O
Fastening thread ASME B1.1 7/16-14UNC-2B; 0.79 (20) deep
Ports Port plate 64 Standard Size pmax [psi (bar)]1) State5)
B Working port ISO 11926 1 1/16 12UN-2B; 0.79 (20) deep 4550 (315) O
S Suction port ISO 11926 1 5/8 12UN-2B ; 0.67 (17) deep 75 (5) O
L Drain port ISO 119262) 3/4-16UNF-2B; 0.47 (12) deep 30 (2) O3)
4) 2)
L1, L2 Drain port ISO 11926 3/4-16UNF-2B; 0.47 (12) deep 30 (2) X3)
X Pilot pressure ISO 11926 7/16-20UNF-2B; 0.45 (11.5) deep 4550 (315) O
1) Depending on the application, momentary pressure peaks can 4) Only for series 53
occur. 5) O = Must be connected (plugged on delivery)
Keep this in mind when selecting measuring devices and fittings. X = Plugged (in normal operation)
2) The countersink may be deeper than specified in the standard.
3) Depending on the installation position, L, L1 or L2 must be
connected (also see installation instructions starting on
page 76).
▼ DRG – Pressure controller, remotely controlled, series 52 ▼ DFR/DFR1 – Pressure and flow controller, series 52
4.23 (107.5)
4.88 (124)
4.23 (107.5)
4.88 (124)
X L X L
L
L
S S
L1 L1
9.45 (240)
4.88 (124)
L
S
L1
▼ DRG – Pressure controller, remotely controlled, series 53 ▼ EP.D. / EK.D. – Electro-proportional control, series 53
5.12 (130)
5.12 (130)
4.49 (114)
4.49 (114)
L L
S S
L2 L2
5.12 (130)
4.61 (117)
4.49 (114)
L L
S L2 L2
▼ LA.D. – Pressure, flow and power controller, series 53 ▼ ED7. / ER7. – Electro-prop. Pressure control, series 53
9.09 (231)
5.51 (140) 2.48 (63)
9.45 (240)
L1 L1
X
5.12 (130)
4.49 (114)
5.12 (130)
L L
S S
L2
L2
Dimensions, size 45
5.19 (132)
ISO 3019-1
0.56 (14.3)
3.03 (77)
L
(Ø101.6 -0.054 )
3.998
DIA 4.000
8)
X
(7
0
1
3.
2.70 (68.5)
7.44 (189) 5.75 (146)
max. 8.68 (220.5) 6.77 (172)
▼ Port plate 62
max. 8.68 (220.5)
3.90 (99)
0.37 (9.5) 0.47 (12) View X1)
0.25 (6.3) 1.18 (30)
L1
Flange
ISO 3019-1
S
)
L
1.50 (ø38) 69.9
0.98 (ø25)
5(
(Ø101.6 -0.054 )
2.7
2.75 (69.9)
DIA 3.998
4.000
0
Y
(ø38)
1.50
(5 06
)
2.4
2.
S
1. B
1.41 1.
(3 41 (2 03 3
(35.7) 5.7 6.2 0°
) 30° )
7.01 (178) 1.50 1.50
8.31 (211) (38) (38)
Detail Z
▼ Port plate 64 B
View Y1)
2.06 (52.4)
0.98 (Ø25)
1.03
(26.2)
Z
S B
B
S
S B
3.54 (90) 3.54 (90)
1.50 1.50
(38) (38)
Dimensions, size 45
▼ Port plate 61
max. 8.50 (216)
3.90 (99)
L1
L1 L X
L
5.22 (132.5)
Flange
4.13 (105)
0.
ISO 3019-1
0.56 (14.3)
08
3.27 (83)
(2
)
45°
(Ø101.6 -0.054)
DIA 3.998
4.000
77
0
.5
3.19 (81)
75
45°
0
(3 .12 L2
3.90 (99) )
5.75 (146)
7.44 (189)
6.77 (172)
▼ Port plate 62
max. 8.50 (216)
View X1)
3.90 (99)
0.37 1.22
(9.5) (31) X
S
0.25 (6.3)
0.98 (⌀25)
.9)
Flange
69
5(
ISO 3019-1
2.7
(⌀38)
1.50
(Ø101.6 -0.054)
2.75 (69.9)
DIA 3.998
4.000
(⌀38)
0
1.50
(5 06
)
2.4
2.
B
S
1.
(3 41 B
S 5.7 1
) 30° (2 .03
6.2
0.47 (12) ) 30°
1.41
3.90 (99) (35.7) 1.50 1.50
(38) (38)
7.01 178) Detail Z
8.31 211)
2.06 (52.4)
0.98 (⌀25)
View Y1)
1.03
(26.2)
Z
S
▼ Splined shaft 1 in (25-4, ISO 3019-1) ▼ Splined shaft 1 in (similar to ISO 3019-1)
1)
S ‒ 15T 16/32DP R ‒ 15T 16/32DP1)2)
1.50 (38)
0.63 (16)
0.63 (16)
3)
1/4-20UNC-2B3)
0.20 (5)
1/4-20UNC-2B
0.20(5)
Usable 1.16
spline length (29.5)
1.18 (30) 1.81 (45.9)
1.81 (45.9)
▼ Splined shaft 7/8 in (22-4, ISO 3019-1) ▼ Splined shaft 7/8 in (similar to ISO 3019-1)
U ‒ 13T 16/32DP1) W ‒ 13T 16/32DP1)2)
1/4-20UNC-2B3)
0.20 (5)
1/4-20UNC-2B3)
0.20 (5)
Usable 0.98
spline length (25)
0.99
(25.1) 1.61 (41)
1.61 (41)
▼ Parallel keyed shaft (ISO 3019-1) ▼ Tapered with woodruff key (ISO 3019-1)
K ‒ 25-1 C
(5) A
)
(Ø21.774+0.006
+0.025
0.8575
DIA 0.8570
0.250(6.35
DIA1.000
(28.2-0.2 )
0.998
1.1102
1.1023
0.251
0.130
B
0.16 (Ø4)
0.13 (3.2) 1.18
(30)
1.81 (46)
2.43 (61.8)
Ports Port plate 61 and 62 Standard Size pmax [psi (bar)]1) State5)
B Working port (standard pressure series) ISO 6162-1 1 in 4550 (315) O
Fastening thread ASME B1.1 3/8-16UNC-2B; 0.71 (18) deep
S Suction port (standard pressure series) ISO 6162-1 1 1/2 in 75 (5) O
Fastening thread ASME B1.1 1/2-13UNC-2B; 0.87 (22) deep
Ports Port plate 64 Standard Size pmax [psi (bar)]4) State5)
B Working port ISO 11926 1 5/16-12UN-2B; 0.79 (20) deep 4550 (315) O
S Suction port ISO 11926 1 7/8-12UN-2B; 0.79 (20) deep 75 (5) O
L Drain port ISO 119262) 7/8-14UNF-2B; 0.51 (13) deep 30 (2) O3)
4) 2)
L1, L2 Drain port ISO 11926 7/8-14UNF-2B; 0.51 (13) deep 30 (2) X3)
X Pilot pressure ISO 11926 7/16-20UNF-2A; 0.45 (11.5) deep 4550 (315) O
▼ DRG – Pressure controller, remotely controlled, series 52 ▼ DFR/DFR1/DRSC – Pressure and flow controller, series 52
L1
5.20 (132)
L1 X
5.20 (132)
X
4.53 (115)
4.53 (115)
L L
S S
9.88 (251)
X L1
5.20 (132)
L L
L
▼ DRG – Pressure controller, remotely controlled, series 53 ▼ EP.D. / EK.D. – Electro-proportional control, series 53
X
L1
5.22 (132.5)
X
X X
4.57 (116)
5.22 (132.5)
4.57 (116)
L
S
S
L2
X
X
4.70 (119.5)
4.57 (116)
5.22 (132.5)
S
S L2
▼ LA.D. – Pressure, flow and power controller, series 53 ▼ ED7. / ER7. – Electro-prop. Pressure control, series 53
9.25 (235)
5.75 (146) 2.68 (68) 9.68 (246)
L1
X X
5.22 (132.5)
X
5.22 (132.5)
4.57 (116)
L
S
S
L2
Dimensions, size 60
▼ Port plate 61
max. 8.68 (220.5)
4.61 (117)
0.37 1.57
(9.5) (40) L1
5.39 (137)
Flange
ISO 3019-1
0.56 (14.3)
3.43 (87)
L 45°
(Ø101.6 -0.054 )
3.998
DIN 4.000
5)
0
8.
X
(7
3.07 (78)
0.59 (15) 5.75 (146)
8.19 (208) 6.77 (172)
View X1)
0.98 (Ø25)
3.06 (77.8)
1.97 (Ø50)
(52.4)
2.06
S B
4.61 (117)
0.98 (Ø25)
3.06 (77.8)
(Ø101.6 -0.054
3.998
DIN 4.000
0
(Ø50)
1.97
Y Z
Dimensions, size 60
▼ Port plate 61
5.39 (137)
Flange
0. 4.
56 3)
ISO 3019-1
(1
3.43 (87)
L
45°
4.51 (114.5)
(Ø127 -0.063 )
4.9975
DIA 5.0000
5.83 (148)
5)
8.
0
(7
X
09
3.
3.07 (78)
0.59 (15) 4.51 (114.5)
8.19 (208) 5.75 (146)
View X1)
0.98 (Ø25)
3.06 (77.8)
1.97 (Ø50)
(52.4)
2.06
B
1.67 (42.9) 1.03 (26.2)
▼ Port plate 62 1.30 1.81
Detail Z
max. 8.68 (220.5) (33) (46)
2.06 (52.4)
0.98 (Ø25)
4.61 (117)
0.50 (12.7) 1.57
(40) View Y1)
X
Flange B
ISO 3019-1 1.03 (26.2)
L
3.06 (77.8)
(Ø127 -0.063 )
4.9975
DIA 5.0000
(Ø50)
1.97
0
Y Z
B
S
Dimensions, size 63
▼ Port plate 61
max. 8.68 (220.5)
4.55 (115.5)
L1
L1
L
5.51 (140)
Flange
4.37 (111)
0.56 (14.3)
ISO 3019-1
3.50 (89)
43°
(Ø101.6 -0.054 )
DIA 3.998
4.000
(7 .11
9)
0
3
X
(7 .05
5)
3.46 (88)
45°
7.
3
L2
4.55 (115.5) 5.75 (146)
8.19 (208) 6.77 (172)
View X1)
0.98 (Ø25)
S B
3.06 (77.8)
1.97 (Ø50)
(52.4)
2.06
S B
3.06 (77.8)
DIA 3.998
4.000
0
(Ø50)
Y Z
1.97
B
S
S
0.59 (15) 1.69
4.55 (115.5) (42.9) 2.83 (72) 2.83 (72)
7.93 (201.5)
9.43 (239.5)
Dimensions, size 63
▼ Port plate 61
4)
5.51 (140)
(1
ISO 3019-1
4.37 (111)
55
0.
3.50 (89)
43°
45°
45°
4.51 (114.5)
(Ø127 -0.063 )
9)
5.75 (146)
4.9975
DIA 5.0000
(7
5)
11
X
0
7.
3.
(7
05
3.46 (88)
45°
3.
L2
0.59 (15)
4.51 (114.5)
8.19 (208)
5.75 (146)
5.91 (150)
View X1)
2.06 (52.4)
0.98 (Ø25)
1.97 (Ø50)
3.06 (77.8)
B
S
▼ Port plate 62 1.69
(42.9) 1.03 (26.2)
1.30 1.81
max. 8.68 (220.5) Detail Z (33) (46)
4.55 (115.5)
2.06 (52.4)
3.06 (77.8)
4.9975
DIA 5.0000
(Ø50)
1.97
0
Y Z
B
S
0.59 (15)
4.55 (115.5) 1.69 2.83 (72) 2.83 (72)
7.93 (201.5) (42.9)
9.43 (239.5)
▼ Splined shaft 1 1/4 in (32-4, ISO 3019-1) ▼ Splined shaft 1 1/4 in (similar to ISO 3019-1)
1)
S ‒ 14T 12/24DP R ‒ 14T 12/24DP1)2)
5/16-18UNC-2B3)
3)
5/16-18UNC-2B 0.75 (19)
0.24 (6)
0.24 (6)
1.56
Usable 1.57 (40)
(39.5) spline length
2.18 (55.4)
2.18 (55.4)
▼ Splined shaft 1 in (25-4, ISO 3019-1) ▼ Splined shaft 1 in (similar to ISO 3019-1)
1)
U ‒ 15T 16/32DP W ‒ 15T 16/32DP1)2)
1.50 (38)
0.63 (16)
0.63 (16)
1/4-20UNC-2B3)
1/4-20UNC-2B3)
0.20 (5) 0.20 (5)
▼ Parallel keyed shaft (ISO 3019-1) ▼ Tapered with woodruff key (ISO 3019-1)
K ‒ 32-1 C
1.87 (47.5)
(ø31.75 -0.03 )
1/4-20UNC-2B 3)
125:1000
0.75 (19)
Key width
0.3223 (7.94+0.25) 0.93 (23.6) 0.3136
0.20 0.3125 0.56 (14.1) 0.3126 (7.94 +0.025 )
1-12UNF-2A3)
(5) A
0.3126 (7.94 +0.025 )
-0.006 )
DIA 1.2399
1.2403
(Ø31.51+0.006
(35.3-0.2 )
DIA1.250
1.249
1.37
0.3136
0.1394
B
0.16 (Ø4) 1.18
0.12 (3) (30)
2.18 (55.4) 2.61 (66.4)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, 3) Thread according to ASME B1.1
flat root, side fit, tolerance class 5
2) Splines according to ANSI B92.1a, spline runout is a deviation from
standard ISO 3019-1.
▼ DRG – Pressure controller, remotely controlled, series 52 ▼ DFR/DFR1/DRSC – Pressure and flow controller, series 52
5.39 (137)
L
5.39 (137)
4.76 (121)
4.76 (121)
S S
9.88 (251)
L1
5.39 (137)1)
L1 L
L S
▼ DRG – Pressure controller, remotely controlled, series 53 ▼ EP.D. / EK.D. – Electro-proportional control, series 53
5.51 (140)
4.88 (124)
4.92 (125)
5.51 (140)
4.88 (124)
L
S S L2
▼ DRF/DRS/DRSC – Pressure and flow controller, ▼ EP.ED. / EK.ED. – Electro-prop. control, series 53
Series 53
5.51 (140)
4.92 (125)
5.51 (140)
4.88 (124)
S
S L2
▼ LA.D. – Pressure, flow and power controller, series 53 ▼ ED7. / ER7. – Electro-prop. Pressure control, series 53
9.72 (247)
5.92 (150.5) 2.56 (65) 9.88 (251)
X
L1 L1
L1 X
5.51 (140)
X
L
4.88 (124)
5.04 (128)
5.51 (140)
S L2 L2
S
Dimensions, size 72
▼ Port plate 61
max. 8.68 (220.5)
4.55 (115.5)
L1
L1
L
5.51 (140)
Flange
4.37 (111)
0.56 (14.3)
ISO 3019-1
3.50 (89)
43°
(Ø101.6 -0.054 )
DIA 3.998
4.000
(7 .11
9)
0
3
X
(7 .05
5)
3.46 (88)
45°
7.
3
L2
4.55 (115.5) 5.75 (146)
8.19 (208) 6.77 (172)
View X1)
0.98 (Ø25)
S B
3.06 (77.8)
1.97 (Ø50)
(52.4)
2.06
S B
3.06 (77.8)
DIA 3.998
4.000
0
(Ø50)
Y Z
1.97
B
S
S
0.59 (15) 1.69
4.55 (115.5) (42.9) 2.83 (72) 2.83 (72)
7.93 (201.5)
9.43 (239.5)
Dimensions, size 72
▼ Port plate 61
max. 8.68 (220.5)
4.55 (115.5)
0.50 (12.7) 1.54
0.25 (6.3) (39)
L1 L1
Flange L
4)
5.51 (140)
(1
ISO 3019-1
4.37 (111)
55
0.
3.50 (89)
43°
5 ° 45°
4
4.51 (114.5)
(Ø127 -0.063 )
9)
5.75 (146)
4.9975
DIA 5.0000
(7
5)
11
X
0
7.
3.
(7
05
3.46 (88)
45°
3.
L2
0.59 (15)
4.51 (114.5)
8.19 (208)
5.75 (146)
5.91 (150)
View X1)
2.06 (52.4)
0.98 (Ø25)
1.97 (Ø50)
3.06 (77.8)
B
S
▼ Port plate 62 1.69
(42.9) 1.03 (26.2)
1.30 1.81
max. 8.68 (220.5) Detail Z
(33) (46)
4.55 (115.5)
2.06 (52.4)
View Y1)
0.25
L1
(6.3)
Flange
ISO 3019-1 B 1.03
(26.2)
(Ø127 -0.063 )
3.06 (77.8)
4.9975
DIA 5.0000
(Ø50)
1.97
0
Y Z
B
S
0.59 (15)
4.55 (115.5) 1.69 2.83 (72) 2.83 (72)
7.93 (201.5) (42.9)
9.43 (239.5)
▼ Splined shaft 1 1/4 in (32-4, ISO 3019-1) ▼ Splined shaft 1 1/4 in (similar to ISO 3019-1)
1)
S ‒ 14T 12/24DP R ‒ 14T 12/24DP1)2)
5/16-18UNC-2B3)
3)
5/16-18UNC-2B 0.75 (19)
0.24 (6)
0.24 (6)
2.18 (55.4)
▼ Splined shaft 1 in (25-4, ISO 3019-1) ▼ Splined shaft 1 in (similar to ISO 3019-1)
1)
U ‒ 15T 16/32DP W ‒ 15T 16/32DP1)2)
1.50 (38)
0.63 (16)
0.63 (16)
1/4-20UNC-2B3)
1/4-20UNC-2B3)
0.20 (5) 0.20 (5)
1.87 (47.5)
(ø31.75 -0.03 )
1/4-20UNC-2B 3)
0.75 (19)
Key width
0.3223 (7.94+0.25)
0.20 0.3125
(5)
(35.3-0.2 )
(Ø34.91)
1.3819
1.3898
DIA1.250
1.249
1.37
2.18 (55.4)
▼ DRG – Pressure controller, remotely controlled, series 53 ▼ EP.D. / EK.D. – Electro-proportional control, series 53
4.88 (124)
4.92 (125)
5.51 (140)
5.51 (140)
4.88 (124)
L L
S L2 S L2
▼ DRF/DRS/DRSC – Pressure and flow controller, series 53 ▼ EP.ED. / EK.ED. – Electro-prop. control, series 53
5.51 (140)
4.92 (125)
5.51 (140)
4.88 (124)
L L
S
S L2 L2
▼ LA.D. – Pressure, flow and power controller, series 53 ▼ ED7. / ER7. – Electro-prop. Pressure control, series 53
9.72 (247)
5.92 (150.5) 2.56 (65) 9.88 (251)
X
L1 L1 L1
5.51 (140)
X X
L
4.88 (124)
5.04 (128)
L
5.51 (140)
S L2 L2
S
Dimensions, size 85
▼ Port plate 61
6.14 (156)
ISO 3019-1
3.68 (93.5)
45°
)
DIA 4.9975
5.0000
(Ø127-0.063
5)
(9
0
74
3.
0.69 (17.5)
3.42 (87)
0.79 (20) 7.13 (181)
9.65 (245) 8.27 (210)
View X1)
1.26 (Ø32)
3.50 (88.9)
2.36 (Ø60)
(66.7)
2.63
B
2.00
(50.8) 1.25 (31.8)
▼ Port plate 62 Detail Z 1.97 1.77
(50) (45)
max. 9.51 (241.5)
2.63 (66.7)
1.26 (Ø32)
5.12 (130)
0.50 (12.7) 1.57 (40) View Y1)
X
B
Flange
ISO 3019-1 1.25
(31.8)
L
)
3.50 (88.9)
DIA 4.9975
5.0000
-0.063
(Ø63)
0
2.48
Y Z
(Ø127
B
S
Dimensions, size 85
5.91 (150)
4.96 (126)
0. )
ISO 3019-1
16
(4
3.98 (101)
45°
3) 4.51 (114.5)
)
(9 .74
DIA 4.9975
5.0000
(Ø127-0.063
74
5)
3
3. 5)
0
X
(9
102.5
45°
0. )
(1 .56
16
(4
4.
0
5.12 (130) L2
9.65 (245) 4.51 (114.5)
5.75 (146)
View X1)
▼ Mounting flange C
1.26 (Ø32)
L1
L
5.91 (150)
4.96 (126)
0. )
16
(4
3.98 (101)
2.36 (Ø60)
3.50 (88.9)
(66.7)
45°
2.63
(9 74
3.
5)
B
(9 .74
4.04 (102.5)
S
0.69 (17.5)
5)
3
45°
2.00
(50.8) 1.25 (31.8)
1.97 1.77 L2
0. )
16
(4
8.27 (210)
▼ Port plate 62 Detail Z
max. 9.90 (251.5)
5.63 (143)
2.63 (66.7)
Flange
ISO 3019-1
B
1.25
(31.8)
)
3.50 (88.9)
DIA 4.9975
5.0000
(Ø127-0.063
(Ø63)
0
2.48
Y Z
B
S
▼ Splined shaft 1 1/2 in (38-4, ISO 3019-1) ▼ Splined shaft 1 1/2 in (similar to ISO 3019-1)
1)
S ‒ 17T 12/24DP R ‒ 17T 12/24DP1)2)
2.13 (54)
1.10 (28)
1.10 (28)
3)
0.37
7/16-14UNC-2B3)
7/16-14UNC-2B
0.37 (9.5)
(9.5)
▼ Splined shaft 1 1/4 in (32-4, ISO 3019-1) ▼ Splined shaft 1 1/4 in (similar to ISO 3019-1)
1)
U ‒ 14T 12/24DP W ‒ 14T 12/24DP1)2)
1.87 (47.5)
0.75 (19) 0.75 (19)
5/16-18UNC-2B3)
5/16-18UNC-2B3)
0.24 (6) 0.24 (6)
2.10 (53.5)
7/16-14UNC-2B 3)
(ø38.1 -0.03 )
DIA1.500
1.499
2.44 (61.9)
▼ DRG – Pressure controller, remotely controlled, series 52 ▼ DFR/DFR1/DRSC – Pressure and flow controller, series 52
6.14 (156)
L
X
5.49(139.5)
6.14 (156)
L
5.49(139.5)
S
S
2.17 (55)
10.69 (271.5) 0.76 (19.4)
L1 X
6.14 (156)
L
▼ DRG – Pressure controller, remotely controlled, series 53 ▼ EP.D. / EK.D. – Electro-proportional control, series 53
5.90 (150)
X
5.24 (133)
X
5.91 (150)
5.59 (142)
L
5.24 (133)
S S L2
L2
▼ DRF/DRS/DRSC – Pressure and flow controller, series 53 ▼ EP.ED. / EK.ED. – Electro-prop. control, series 53
L
X
5.24 (133)
5.91 (150)
L
5.24 (133)
S S L2
L2
▼ LA.D. – Pressure, flow and power controller, series 53 ▼ ED7. / ER7. – Electro-prop. Pressure control, series 53
X L
L
5.71(145)
5.24 (133)
5.91 (150)
L2 S L2
S
▼ Port plate 61
0.
16
Flange
5.91 (150)
(4
)
ISO 3019-1
5)
(9
5)
0
(9
74
74
3.
DIA
0.69 (17.5)
3.
45°
0.
16
(4
)
5.12 (130) L2
9.65 (245) 7.13 (181)
8.27 (210)
View X1)
(Ø32)
1.26
3.50 (88.9)
2.36 (Ø60)
(66.7)
2.62
S B
2.00
(50.8) 1.25
▼ Port plate 62
1.26 (Ø32)
View Y1)
0.50 (12.7) 1.42 (36)
L1 X
Flange
ISO 3019-1 B 1.25
(31.8)
L
3.50 (88.9)
)
DIA5.0000
4.9975
(Ø127-0.063
(Ø63)
2.48
Y Z
0
B
S
▼ Port plate 61
max. 9.90 (251.5)
5.63 (143)
0.50 (12.7) 1.42 (36) L1
L1 X
0.
16
Flange
5.91 (150)
(4
4.96 (126)
ISO 3019-1
3.98 (101)
L L
45°
4.51 (114.5)
(Ø127 -0.063 )
5.0000
DIA 4.9975
5)
(9
5)
0
(9
74
74
4.04 (102.5)
3.
3.
45°
0.
16
(4
)
5.12 (130) L2
4. 6
(1 .5
3)
0
9.65 (245) 4.51 (114.5)
5.75 (146)
View X1)
1.26 (Ø32)
2.36 (Ø60)
3.50 (88.9)
(66.7)
2.62
S B
2.00
(50.8) 1.25
(31.8)
▼ Port plate 62 1.97 1.77
Detail Z (50) (45)
(Ø32)
5.63 (143)
2.63 (66.7)
Flange
ISO 3019-1
B
1.25
L (31.8)
)
3.50 (88.9)
DIA 5.0000
4.9975
(Ø127 -0.063
(Ø63)
Y Z
2.48
0
B
S
▼ Splined shaft 1 1/2 in (38-4, ISO 3019-1) ▼ Splined shaft 1 1/2 in (similar to ISO 3019-1)
1)
S ‒ 17T 12/24DP R ‒ 17T 12/24DP1)2)
2.13 (54)
1.10 (28)
1.10 (28)
3)
0.37
7/16-14UNC-2B3)
7/16-14UNC-2B
0.37 (9.5)
(9.5)
▼ Splined shaft 1 1/4 in (32-4, ISO 3019-1) ▼ Splined shaft 1 1/4 in (similar to ISO 3019-1)
1)
U ‒ 14T 12/24DP W ‒ 14T 12/24DP1)2)
1.87 (47.5)
0.75 (19) 0.75 (19)
5/16-18UNC-2B3)
5/16-18UNC-2B3)
0.24 (6) 0.24 (6)
2.10 (53.5)
7/16-14UNC-2B 3)
(ø38.1 -0.03 )
DIA1.500
1.499
2.44 (61.9)
▼ DRG – Pressure controller, remotely controlled, series 53 ▼ EP.D. / EK.D. – Electro-proportional control, series 53
5.91 (150)
L X
5.24 (133)
5.91 (150)
5.59 (142)
L
5.24 (133)
S L2 S L2
▼ DRF/DRS/DRSC – Pressure and flow controller, series 53 ▼ EP.ED. / EK.ED. – Electro-prop. control, series 53
L
5.24 (133)
5.91 (150)
L
5.24 (133)
S L2
S L2
▼ LA.D. – Pressure, flow and power controller, series 53 ▼ ED7. / ER7. – Electro-prop. Pressure control, series 53
10.71 (272)
10.67 (271)
L1
7.15 (181.5) X 2.91 (74)
X
L1
6.14 (156)
X
L
L
5.71(145)
5.24 (133)
5.91 (150)
S L2
S L2
Flange ISO 3019-1 (SAE) Hub for splined shaft1) Availability across sizes Code
Diameter Mounting2) Diameter 18 28 45 60/63 72 85 100
82-2 (A) , 5/8 in 9T 16/32DP ● ● ● ● ● ● ● K01
3/4 in 11T 16/32DP ● ● ● ● ● ● ● K52
● = Available ○ = On request
82-2
A3
Omitted for NG 18 and 28 A2 Omitted for NG 18 and 28
A2
45°
45°
(ø82.55 +0.020 )
(ø82.55 +0.020 )
+0.050
DIA 3.2520
3.2508
+0.050
DIA 3.2520
3.2508
A B A B
4. 4
(ø1 19 (ø1 .19
06. 06
5) .5)
A4 0.39 A4
0.39
(10) (10)
Omitted for NG 18 and 28 Omitted for NG 18 and 28 A3
A1 (to mounting flange)
A1 (to mounting flange)
1) According to ANSI B92.1a, 30° pressure angle, flat root, side fit, 3) Thread according to DIN 13.
tolerance class 5 4) Minimum dimensions
2) Mounting holes pattern viewed on through drive with control at top
Flange ISO 3019-1 (SAE) Hub for splined shaft1) Availability across sizes Code
Diameter Mounting2) Diameter 18 28 45 60/63 72 85 100
101-2 (B) , 7/8 in 13T 16/32DP – ● ● ● ● ● ● K68
1 in 15T 16/32DP – – ● ● ● ● ● K04
● = Available ○ = On request
101-2
45°
45
+0.020 )
+0.020 )
(ø101.6 +0.050
(ø101.6 +0.050
4.0020
DIA 4.0008
°
4.0020
DIA 4.0008
A B A B
5.7 5.7
(ø1 5 (14 5
46 6)
)
A4 A4
0.39
(10) 0.39
Omitted for NG 28, 45 A3 Omitted for NG 45 A2 (10)
A1 (to mounting flange) A1 (to mounting flange)
1) According to ANSI B92.1a, 30° pressure angle, flat root, side fit, 3) Thread according to DIN 13.
tolerance class 5 4) Minimum dimensions
2) Mounting holes pattern viewed on through drive with control at top
Flange ISO 3019-1 (SAE) Hub for splined shaft1) Availability across sizes Code
Diameter Mounting2) Diameter 18 28 45 60/63 72 85 100
127-4 (C) 1 1/4 in 14T 12/24DP – – – ● ● ● ● K15
1 1/2 in 17T 12/24DP – – – – – ● ● K16
● = Available ○ = On request
127-4
A3 A3
A2 A A2
A
4.51 (114.5)
+0.020 )
(ø127 +0.020 )
5.001
DIA 5.002
4.51 (114.5)
5.0020
DIA 5.0008
+0.050
(ø127 +0.050
0.51
4.51 (114.5) A4
4.51 (114.5) A4 (13) 0.53
(13.4)
B B
A1 (to mounting flange) A1 (to mounting flange)
1) According to ANSI B92.1a, 30° pressure angle, flat root, side fit, 3) Thread according to DIN 13.
tolerance class 5 4) Minimum dimensions
2) Mounting holes pattern viewed on through drive with control at top
Flange ISO 3019-1 (SAE) Hub for splined shaft1) Availability across sizes Code
Diameter Mounting2) Diameter 18 28 45 60/63 72 85 100
127-2 (B) , 1 1/4 in 14T 12/24DP – – – – – ● ● K07
1 1/2 in 17T 12/24DP – – – – – ● ● K24
● = Available ○ = On request
127-2
45° 45° A3
A
A2 A A2
(Ø127 +0.020 )
5.0020
DIA 5.0008
+0.050
3
3
7.1 81) 7.1 1)
(Ø127 +0.020 )
5.0020
DIA 5.0008
+0.050
8
(Ø1 (Ø1
A4 A4
B
B 0.51
A3 (13) 0.51
(13)
A1 (to mounting flange) A1 (to mounting flange)
1) According to ANSI B92.1a, 30° pressure angle, flat root, side fit, 3) Thread according to DIN 13.
tolerance class 5 4) Minimum dimensions
2) Mounting holes pattern viewed on through drive with control at top
Notice
Through drives with installed hub are supplied with
a spacer.
The spacer must be removed before the 2nd pump is
installed and before commissioning. For further
information, see instruction manual 92703-01-B
▼ Switching symbol
Consisting of DT designation
1 housing DT06-2S-EP04
1 wedge W2S
2 sockets 0462-201-16141
Control electronics
Control Electronics function Electronics Data sheet
Electric pressure control Controlled power outlet RA analog 95230
RC4-5/30 digital 95205
Installation instructions
S
1) Because complete air bleeding and filling are not possible in this
position, the pump should be air bled and filled in a horizontal
position before installation. L
2) For NG10 and NG28 series 52, L1 is opposite, L must then be L1
connected if necessary.
3) Only series 53
Above-reservoir installation
Above-reservoir installation means that the axial piston A check valve in the case drain line is only permissible in
unit is installed above the minimum fluid level of the individual cases. Consult us for approval.
reservoir. To prevent the axial piston unit from draining
in position 6, the height difference hES min must be at
least 0.98 inch (25 mm). Observe the maximum For key, see page 78.
permissible suction height hS max = 31.5 inch (800 mm).
Installation position Air bleed Filling
52) F L1 or L
F
L
L1 X
hs max
S
ht min
SB
h min
61)2) F L1
F
hES min
L1
S L
X
hs max
ht min
SB
h min
73) F L2
F
L2
L1 L S
hs max
ht min
SB
h min
81) F S or L
F
S
L
L1
hs max
ht min SB
h min
1) Because complete air bleeding and filling are not possible in this
position, the pump should be air bled and filled in a horizontal
position before installation.
2) For NG10 and NG28 series 52, L1 is opposite, L must then be
connected if necessary.
3) Only series 53
position under
Notice
h t min
SB the hydraulic
fluid level Port F is part of the external piping and must be provided
S on the customer side to make filling and air bleeding
easier.
h min
L the hydraulic
X
fluid level
S
h min
113)
L2
h t min
L S
SB
h min
position under
the hydraulic
L fluid level
L1
h min
1) Because complete air bleeding and filling are not possible in this
position, the pump should be air bled and filled in a horizontal
position before installation.
2) For NG10 and NG28 series 52, L1 is opposite, L must then be
connected if necessary.
3) Only series 53
▶ The A10VO axial piston variable pump is designed to ▶ Pressure controllers are not safeguards against
be used in open circuit. pressure overload. Be sure to add a pressure relief
▶ Project planning, installation and commissioning of the valve to the hydraulic system.
axial piston units requires the involvement of skilled ▶ For drives that are operated for a long period of time
personnel. with constant rotational speed, the natural frequency
▶ Before using the axial piston unit, please read the of the hydraulic system can be stimulated by the
corresponding instruction manual completely and excitation frequency of the pump (rotational speed
thoroughly. If necessary, this can be requested from frequency ×9). This can be prevented with suitably
Bosch Rexroth. designed hydraulic lines.
▶ Before finalizing your design, request a binding ▶ Please note the details regarding the tightening torques
installation drawing. of port threads and other threaded joints in the
▶ The specified data and notes contained herein must be instruction manual.
observed. ▶ Working ports:
▶ Depending on the operating conditions of the axial – The ports and fastening threads are designed for
piston unit (working pressure, fluid temperature), the specified maximum pressure. The machine or
the characteristic curve may shift. The characteristic system manufacturer must ensure the connecting
curve may also shift due to the dither frequency or elements and lines correspond to the specified
control electronics. application conditions (pressure, flow, hydraulic
▶ Preservation: Our axial piston units are supplied as fluid, temperature) with the necessary safety
standard with preservation protection for a maximum of factors.
12 months. If longer preservation protection is required – The service ports and function ports are only
(maximum 24 months), please specify this in plain text intended to accommodate hydraulic lines.
when placing your order. The preservation periods
apply under optimal storage conditions, details of which
can be found in the data sheet 90312 or the instruction
manual.
▶ Not all versions of the product are approved for use in
safety functions according to ISO 13849. Please consult
the proper contact at Bosch Rexroth if you require
reliability parameters (e.g. MTTFd) for functional safety.
▶ Depending on the type of control used, electromagnetic
effects can be produced when using solenoids. Applying
a direct voltage signal (DC) to solenoids does not create
electromagnetic interference (EMI) nor is the solenoid
affected by EMI. Electromagnetic interference (EMI)
potential exists when operating and controlling
a solenoid with a modulated direct voltage signal
(e.g. PWM signal) Appropriate testing and measures
should be taken by the machine manufacturer to ensure
other components or operators (e.g. with pacemaker)
are not affected by this potential.
Safety instructions
Bosch Rexroth Corporation © Bosch Rexroth Corporation 2021. All rights reserved, also regarding any
8 Southchase Court disposal, exploitation, reproduction, editing, distribution, as well as in the
Fountain Inn, SC 29644-9018 event of applications for industrial property rights. The data specified within
USA only serves to describe the product. No statements concerning a certain
Telephone (864) 967-2777 condition or suitability for a certain application can be derived from our
Facsimile (864) 962-5338 information. The information given does not release the user from the
www.boschrexroth-us.com obligation of own judgment and verification. It must be remembered that our
products are subject to a natural process of wear and aging.