MyFAST 4.0 150m3 Dan
MyFAST 4.0 150m3 Dan
MyFAST 4.0 150m3 Dan
0 BASIC
Product Description & Layout
OPTIONS
8" MIN
20cm MIN Aeration Management System (AMS)
LIXOR® aeration system provides oxygen
Biosolids Airlines and mixing, reducing primary sludge.
Collection Pump
Biosolids Collection 1. LIXOR® 4.0 XD
Grid 2. Blower & Blower Housing
-- Control Panel
MyFAST® 4.0 DETAIL A
OPTIONAL: MyTEE®Screen, AMS & BMS SCALE 1 : 25 Biosolids Management System (BMS)
Influent LIXOR® aeration system to reduce biosolids
(See optional 2
quantity.
MyTEE® Screen)
Treatment 3. LIXOR® 2.0
Zone 4. Blower & Blower Housing
5. Jib Crane
SaniTEE® 6. Decant Pump
1618 Screens -- Control Panel
MyTEE®Screen
A prescreening device is required prior to
AMS Zone. MyTEE® screen provides
separation of non-biological solids and grit.
See sheet 5 of 8 MyTEE® Screen
AMS Zone
1 DO NOT SCALE
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A Layout SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN CTC 3/27/2009 1 OF 8
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV. INI-10-T
MyFAST® 4.0 TANK DETAILS
186"±10" 453 5/8"±10"
472cm±25 1152cm±25
Lid Access Requirements
detailed drawings available upon request
Settling Zone Treatment Zone (5) Access Ports
Influent from source or Or 235 1/2"±5"
from MyTEE® Screen AMS Zone Influent from source or
when prescreening is 598cm±13 Decant from MyTEE® Screen when
required Pump prescreening is required
see sheet 5 of 8 Access see sheet 5 of 8
(4) 16" SaniTEE®
48" MIN Access
122cm MIN
23" Freeboard
36" MIN Overflow
58cm
91cm MIN
8"
A
20cm B
43" MIN
109cm MIN 76 3/4"±1/8" NOTES:
(4) 8"[20.3cm] 194.9cm±0.3 When tank is covered adequate ventilation will be required,
holes for SaniTEE® (2) 6" PVC refer to the BASIC, AMS, & BMS Specification sheets for
installation Pipe openings additional details.
for FAST outlets
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A Tank Details SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN CTC 3/27/2009 2 OF 8
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV. INI-05-X
Secure Biosolids
C C Collection Grid at every
cross, tee, & end cap
BioSolids Discharge to
with non corrosive Bio Solids
Pump provided
clamps (provided by Management
by Bio-Microbics others). System Zone
Liner Placement
304 1/2"
773.4cm
SECTION C-C
All 3" PVC pipe shown
in Section C-C will be
provided by others.
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A Biosolids Collection System SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN CTC 3/27/2009 3 OF 8
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV. INI-10-T
Biosolids Management System (BMS) Option Aeration Management System (AMS) Option
Jib
Crane
See note 2
Decant Pump
See note 2
LIXOR DETAIL
LIXOR® 2.0
LIXOR® 4.0XD
NOTES
1. Blower piping to LIXOR® may not exceed 100 FT [30.5m] in total length and use a maximum of 6 elbows, to get to
the LIXOR air inlet. For distances greater than 100 FT [30.5m] - consult factory. Blower must be located above
flood/standing water levels on a concrete base 36" X 58" X 2" [91X147X5cm] minimum. DO NOT SCALE
2. The air supply line must be secured with a non-corrosive clamp every 2' [0.6m] minimum to prevent vibration UNLESS NOTED
induced damage. DIMENSIONS
ARE IN INCHES
3. Refer to sheet 7 of 8 & 8 of 8 for additional details. [CENTIMETERS]
TOLERANCES
4. Installation of the LIXOR® shall be done in accordance with the written instructions provided by the ± 0.02 IN/IN
manufacturer. Refer to LIXOR® Installation Manual for more details. [± 0.05 CM/CM] MyFAST 4.0
WEIGHT lb SIZE DRAWING NUMBER
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A Options SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN CTC 3/27/2009 4 OF 8
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV. INI-10-T
Emergency 18 1/2" MIN
Inlet overflow 47cm MIN Tank access
see note 3
Center of outlet
22 3/4" MIN and edge of tank
15 3/4" MIN
58cm MIN
40cm MIN
A
24" MIN
50 1/4" 61cm MIN
127.6cm Service access
3rd
SaniTEE
not Shown Base 36 3/4" MIN
secured 93.3cm MIN
to wall. Distance
Emergency overflow
between screens
see note 3
NOTES:
1. MyTEE® screens provide separation of non-
biological solids and grit.
2. Each1638 MyTEE® unit should be placed
under a 24"[61cm] riser for proper
operation of the internal and external swabs.
3. Tank inlet flow line must be at least 2" above
the emergency overflow outlet flow line. MyTEE® 1638 Screen
Emergency overflow must be sized to handle MyTEE®
the designed peak flow event. Flow Maximum Tank Volumes
Emergency Quantity
4. See table for required MyTEE® quantities and 20 000 GPD
overflow maximum tank volume. (1) 2500 gallon [10m3] tank 2
see note 3 [76 m3/Day]
5. Outlet pipe not included. 40 000 GPD
6. All appurtenances to MyTEE® (e.g. septic [150 m3/Day] (1) 5000 gallon [19m3] tank 2
tank, access risers, etc) must conform to all
applicable codes. 60 000 GPD (1) 7500 gallon [28m3] tank 3
7. See additional details in MyFAST® Installation [230 m3/Day]
Manual. 80 000 GPD
[300 m3/Day] (1) 10000 gallon [38m3] tank 4
120 000 GPD
[454 m3/Day] (1) 15000 gallon [55m3] tank 6
8" 160 000 GPD (1) 20000 gallon [75m3] tank 8
20.3cm [600 m3/Day]
DO NOT SCALE
UNLESS NOTED
If installed as shown in a Outlet DIMENSIONS
single compartment tank the optional 8" PVC pipe ARE IN INCHES
8" PVC pipe must be water provided by others [CENTIMETERS]
tight within the tank and flush to connect outlet to TOLERANCES
against the inside to mount
DETAIL A secondary tank ± 0.02 IN/IN
[± 0.05 CM/CM] MyFAST 4.0
16" MyTEE® bottom diverter
WEIGHT lb SIZE DRAWING NUMBER
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A MyTEE® SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN CTC 3/27/2009 5 OF 8
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV. INI-01-Q
Specifications for MyFAST® 4.0 BASIC Wastewater Treatment System
1. GENERAL
The MyFAST® 4.0 treatment system is designed to treat approximately 40,000 GPD (151 m3/day) of residential strength wastewater. For non-residential or mixed use applications, consult the
factory for guidance.The principal items of equipment shall include four (4) FAST® interconnecting liners with leg attachments, airlifts, hoses, biosolids collection manifold, sludge pump, four
(4) SaniTEE® screens, blower assembly, and control panel. The MyFAST®4.0 treatment unit shall be situated within a 40,000 gallon (151 m3) minimum tank, as shown on the plans. Settling
tank(s)/AMS Zone equaling ½ to 1x daily flow must be used prior to MyFAST®. Tank(s) provided must conform to local, state, and all other applicable codes. The tank is to be supplied by
others according to Bio-Microbics dimensions.
2.BLOWER
The blower shall be capable of delivering 400 to 700 CFM [680 - 1190 m3/hr]. The blower assembly shall include an inlet filter with metal filter element. The blower shall be mounted outside the
tank adjacent to the Treatment Zone on a contractor supplied concrete base. The blower elevation must be higher than the water level in the tank and above any normal flood level. A
two-piece, blower housing shall be provided with tamper-proof screws. Blower piping to the tank shall use non-corrosive material (Galvanized or Stainless Steel). Do not run galvanized pipe
inside the treatment tank. Refer to installation manual for further details. The 4 inch NPT Steel discharge air line, MyFAST® 4 inch NPT air header and connections shall be provided and
installed by others.
3. VENTILATION
Vent to desired location and cover opening with a vent grate with at least 120 sq in. [775 sq. cm] open surface area. Secure with Stainless Steel screws. Vent piping must not allow
condensate build up or create back pressure. Vent must be above finished grade or higher.
6. MEDIA
The MyFAST® media shall be manufactured of rigid PVC, polyethylene, or polypropylene and it shall be supported by the polyethylene insert. The media shall be fixed in position and contain
no moving or wearing parts and shall not corrode. The media shall be designed and installed to ensure that sloughed solids descend through the media to the bottom of the tank.
8. WARRANTY
Bio-Microbics, Inc. warrants all new MyFAST® models (MyFAST® 2.0, 4.0, 6.0, 8.0, 12.0, and 16.0) against defects in materials and workmanship for a period of one year after installation or
eighteen (18 months) from the date of shipment whichever occurs first, subject to the following terms and conditions:
During the warranty period, if any part is defective or fails to perform as specified when operating at design conditions, and if the equipment has been installed and is being operated and
maintained in accordance with the written instructions provided by Bio-Microbics, Inc., Bio-Microbics, Inc. will repair or replace at its discretion such defective parts free of charge. Defective
parts must be returned by owner to Bio-Microbics, Inc.’s factory postage paid, if so requested. The cost of labor and all other expenses resulting from replacement of the defective parts and
from installation of parts furnished under this warranty and regular maintenance items such as filters or bulbs shall be borne by the owner. This warranty does not cover general system misuse,
aerator components which have been damaged by flooding or any components that have been disassembled by unauthorized persons, improperly installed or damaged due to altered or
improper wiring or overload protection. This warranty applies only to the treatment plant and does not include any of the
structure wiring, plumbing, drainage, septic tank or disposal system. Bio-Microbics, Inc. is reserves the right to revise, change DO NOT SCALE
or modify the construction and/or design of the MyFAST system, or any component part or parts thereof, without incurring
any obligation to make such changes or modifications in present equipment. Bio-Microbics, Inc. is not responsible for UNLESS NOTED
consequential or incidental damages of any nature resulting from such things as, but not limited to, defect in design, DIMENSIONS
material, or workmanship, or delays in delivery, replacements or repairs. ARE IN INCHES
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED. BIO-MICROBICS SPECIFICALLY [CENTIMETERS]
DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NO TOLERANCES
REPRESENTATIVE OR PERSON IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR TO ASSUME FOR ± 0.02 IN/IN
BIO-MICROBICS, INC., ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS. [± 0.05 CM/CM] MyFAST 4.0
Contact your local distributor for parts and service. WEIGHT lb SIZE DRAWING NUMBER
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A BASIC Specifications SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN 3/27/2009 6 OF 8
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV.
AERATION MANAGEMENT SYSTEM (AMS) OPTION
1. GENERAL INSTALLATION INSTRUCTIONS
All work must be done in accordance with local codes and regulations. Installation of the Aeration Management System (AMS) Option shall be done in accordance with the written
instructions provided by the manufacturer. Manuals which include descriptions of system installation, operation, and maintenance procedures shall be furnished. For further details refer
to the Installation Manual.
3. LIXOR® 4.0XD
The LIXOR® 4.0XD system shall provide mixing to reduce primary sludge settling prior to the Treatment Zone. The contractor shall furnish and install (1) LIXOR® 4.0XD aeration system in the
AMS Zone of the MyFAST®. The system shall be complete with all needed equipment as shown on the drawings and specified herein. The principal items of equipment shall include
LIXOR® aerator, blower assembly, blower controls and alarms. All other items will be provided by others.
The LIXOR® 4.0XD system shall be evenly distributed within the AMS Z one as shown on the plans so as to maximize mixing and reduce settling. The AMS Z one Tank(s) must provide
adequate access for service activities and comply with all state and local codes.
• LIXOR® AERATOR
The LIXOR® aerator shall be manufactured of rigid PVC and ABS. The aerator shall be fixed in position anchored by non corrosive fasteners supplied by others and contain
no moving or wearing parts and shall not corrode.
• BLOWER
The LIXOR® 4.0XD system shall come equipped with a regenerative type blower capable of delivering 60-140 CFM [102-238 m3/hr]. The blower assembly shall include an
inlet filter with metal filter element. The blower shall be secured on the walkway or perimeter, of tank on a contractor supplied base. The blower must not set in standing
water and its elevation must be higher than the normal flood level and higher than the tanks operating level. A two-piece, blower housing shall be provided. The
discharge air line from the blower to the LIXOR® unit shall be provided and installed by others.
• ELECTRICAL
The electrical source should be within 150 feet [45.7 meters] of the blower. Consult local codes for longer wiring distances. All wiring must conform to all applicable codes
(IEC, NEC, etc.). Wiring distances must prevent significant voltage loss. Input power on 60Hz electrical system is 3Ø 208-230/460 VAC, and 19.7/11.4 FLA. Input power on
50Hz electrical system is 3Ø, 230/400 VAC, and 19.7/11.4 FLA. All conduit and wiring shall be supplied by others.
• CONTROLS
The standard control panel provides power to the blower with an alarm system equipped with a visual and audible alarm capable of signaling blower circuit failure. A
manual silence button in included.
• VENTILATION
If the AMS Zone is covered vent to desired location and cover opening with a vent grate with at least 13 sq in. [80 sq. cm] open surface area. Secure with Stainless Steel
screws. Vent piping must not allow condensate build up or create back pressure. Vent must be above finished grade or higher.
4.WARRANTY
Bio-Microbics, Inc. warrants all Bio-Microbics supplied AMS components against defects in materials and workmanship for a period of one year after installation or eighteen months from
date of shipment which ever occurs first, subject to the following terms and conditions:
During the warranty period, if any part is defective or fails to perform as specified when operating at design conditions, and if the equipment has been installed and is being operated
and maintained in accordance with the written instructions provided by Bio-Microbics, Inc. Bio-Microbics, Inc. will repair or replace at its discretion such defective parts free of charge.
Defective parts must be returned by owner to Bio-Microbics, Inc.’s factory postage paid, if so requested. The cost of labor and all other expenses resulting from replacement of the
defective parts and from installation of parts furnished under this warranty and regular maintenance items such as filters or bulbs shall be borne by the owner. This warranty does not
cover: general system misuse, aerator components which have been damaged by flooding or any components that have been disassembled by unauthorized persons, improperly
installed or damaged due to altered or improper wiring or overload protection. This warranty applies only to the AMS components and does not include any of the structure wiring,
plumbing, drainage, septic tank or disposal system. Bio-Microbics, Inc. reserves the right to revise, change or modify the construction and/or design of the components, without incurring
any obligation to make such
changes or modifications in present equipment. Bio-Microbics, Inc. is not responsible for consequential or
incidental damages of any nature resulting from such things as, but not limited to, defect in design, material,
or workmanship, or delays in delivery, replacements or repairs. DO NOT SCALE
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED. BIO-MICROBICS SPECIFICALLY UNLESS NOTED
DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. DIMENSIONS
NO REPRESENTATIVE OR PERSON IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR TO ASSUME FOR ARE IN INCHES
BIO-MICROBICS, INC., ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS. [CENTIMETERS]
Contact your local distributor for parts and service. TOLERANCES
± 0.02 IN/IN
[± 0.05 CM/CM] MyFAST 4.0
WEIGHT lb SIZE DRAWING NUMBER
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A AMS Specifications SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN 3/27/2009 7 OF 8
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV.
BIOSOLIDS MANAGEMENT SYSTEM (BMS) OPTION
1. GENERAL INSTALLATION INSTRUCTIONS
All work must be done in accordance with local codes and regulations. Installation of the BMS Option shall be done in accordance with the written instructions provided by the
manufacturer. Manuals which include descriptions of system installation, operation, and maintenance procedures shall be furnished. For further details refer to the Installation Manual.
• LIXOR® AERATOR
The LIXOR® aerator shall be manufactured of rigid PVC and ABS. The aerator shall be fixed in position anchored by non corrosive fasteners supplied by others and contain no
moving or wearing parts and shall not corrode.
• BLOWER
The LIXOR® 2.0 system shall come equipped with a regenerative type blower capable of delivering 20-50 CFM [34-85 m3/hr]. The blower assembly shall include an inlet filter
with metal filter element. The blower shall be secured on the walkway or perimeter of tank on a contractor supplied base. The blower must not set in standing water and its
elevation must be higher than the normal flood level and the tank's operating level. A two-piece, blower housing shall be provided. The discharge air line from the blower to
the LIXOR® unit shall be provided and installed by others.
• ELECTRICAL
The electrical source should be within 150 feet [45.7 meters] of the blower consult local codes for longer wiring distances. All wiring must conform to all applicable codes (IEC,
NEC, etc.). Wiring distances must prevent significant voltage loss. Input power on 60Hz electrical system is 3Ø, 208-230/460 VAC, and 6.3/2.9 FLA. Input power on 50Hz electrical
system is 3Ø, 230/400 VAC, and 6.1/3.5 FLA. All conduit and wiring shall be supplied by others.
• CONTROLS
The standard control panel provides power to the blower with an alarm system consisting of a visual and audible alarm capable of signaling blower circuit failure. A manual
silence button in included
• VENTILATION
If the BMS zone is covered vent to desired location and cover opening with a vent grate with at least 7 sq in. [45 sq. cm] open surface area. Secure with Stainless Steel screws.
Vent piping must not allow condensate build up or create back pressure. Vent must be above finished grade or higher.
4. WARRANTY
Bio-Microbics, Inc. warrants all Bio-Microbics supplied BMS components against defects in materials and workmanship for a period of one year after installation or eighteen months from date
of shipment which ever occurs first, subject to the following terms and conditions:
During the warranty period, if any part is defective or fails to perform as specified when operating at design conditions, and if the equipment has been installed and is being operated and
maintained in accordance with the written instructions provided by Bio-Microbics, Inc., Bio-Microbics, Inc. will repair or replace at its discretion such defective parts free of charge. Defective
parts must be returned by owner to Bio-Microbics, Inc.’s factory postage paid, if so requested. The cost of labor and all other expenses resulting from replacement of the defective parts and
from installation of parts furnished under this warranty and regular maintenance items such as filters or bulbs shall be borne by the owner. This warranty does not cover: general system misuse,
aerator components which have been damaged by flooding or any components that have been disassembled by unauthorized
persons, improperly installed or damaged due to altered or improper wiring or overload protection. This warranty applies only to
the BMS components and does not include any of the structure wiring, plumbing, drainage, septic tank or disposal system. DO NOT SCALE
Bio-Microbics, Inc. reserves the right to revise, change or modify the construction and/or design of the components, without
incurring any obligation to make such changes or modifications in present equipment. Bio-Microbics, Inc. is not responsible for UNLESS NOTED
consequential or incidental damages of any nature resulting from such things as, but not limited to, defect in design, material, DIMENSIONS
ARE IN INCHES
or workmanship, or delays in delivery, replacements or repairs.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED. BIO-MICROBICS SPECIFICALLY DISCLAIMS ANY IMPLIED [CENTIMETERS]
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NO REPRESENTATIVE OR PERSON IS AUTHORIZED TO TOLERANCES
± 0.02 IN/IN
GIVE ANY OTHER WARRANTY OR TO ASSUME FOR BIO-MICROBICS, INC., ANY OTHER MyFAST 4.0
LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS. Contact your local distributor for parts and service. [± 0.05 CM/CM]
WEIGHT lb SIZE DRAWING NUMBER
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A NAME DATE
A BMS Specifications SHEET
WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE BIO-MICROBICS © 2014 DRAWN 3/27/2009 8 OF 8
INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
CHECKED PF 9/19/2013 REVISED 9/19/2013 REV.