The P2 panelboard from Siemens offers flexibility with a wide array of factory-assembled options to meet various lighting and distribution panel applications. It includes 250A or 600A bus ratings in copper or aluminum. Standard panels have 9-45 inches of unit space with up to 54 neutral connections, while extended panels have 33-45 inches of space and over 100 neutral connections. The P2 uses a stepped numbering system and offers 1-pole and 2/3-pole breakers from 15-100 amps with various interrupting ratings.

Uploaded by

vvargas
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views

Sie CS P2

The P2 panelboard from Siemens offers flexibility with a wide array of factory-assembled options to meet various lighting and distribution panel applications. It includes 250A or 600A bus ratings in copper or aluminum. Standard panels have 9-45 inches of unit space with up to 54 neutral connections, while extended panels have 33-45 inches of space and over 100 neutral connections. The P2 uses a stepped numbering system and offers 1-pole and 2/3-pole breakers from 15-100 amps with various interrupting ratings.

Uploaded by

vvargas
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

DATA SHEET

P2 Panelboards
usa.siemens.com/panelboards

Product Description

The current generation of panelboards from Siemens offers the high level of engineering and
innovation you’ve come to expect from the leader in power distribution technology. The “P Series”
line of panelboards offers a stepped approach to power distribution. (P1-P2-P3-P4-P5)

Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factory-assembled
options to meet virtually any lighting panel application. The ability to mix breaker frames within the
unit space up to 250 amps will also meet certain distribution panel requirements in a much smaller
package.

P2 construction includes the following:


• 250A or 600A max. panel bus ratings in CU or AL
• Standard Circuit P2 Panels from 9” to 45” of unit space with max. 54 neutral connections.
• Extended Circuit P2 Panels with 33-45” of unit space. Total available neutral connections vary by
configuration but some offer over 100 neutral connections.
* P2 Bussing options: Temp rated CU or AL with Tin plating; 750 A/Si AL or 1000 A/Si CU with Tin
plating; Silver Plated CU is available in both above configurations.
**P2 Unit Space starts with 9” (18 circuits of 1-pole breakers) and increases in 6” increments as
needed. Breakers mounted in the unit space can be mixed and matched to meet customer
requirements.

Standards & Certifications:


• NEC: 2020 (where accepted), NEMA PB 1 and ANSI/NEMA PB1.1
• UL Listed: 67, 50 and 50E. (see “Panelboards” File #E2269, and #E4016) Also meets Federal
Specification W-P-115c.
• NFPA 70 compliant (Enclosures are not fire rated).
• Seismically qualified and OSHPD rated (OSP #0078)- see also LVTM-LVSEI-xxxx Seismic Flie
2 P2 Panelboards

Features Overview

The P2 Series lighting panel features include:


1) Fas-Latch trim (Type 1), is standard but, can be ordered with other popular front styles.
2) Adjustable Interiors with jacking screw system.
3) Neutral Configurations are all located at the Main end of the panel. Both Standard Circuit and
Extended Circuit configurations are available with 56-116 total connections available. Qty and
size varies depending on configuration
4) Unit Space is very Flexible with many Field installable kits that allow changes in the field as
requirements change. BL/BQD kits, 3VA41/xGB kits, QR kits and 3VA52/61/62 kits allow changes
in either 3” or 6” increments.
5) Main Breakers are field replaceable within the original breaker Frame size. Frame types cannot
be changed in the field. Strap kits determine max. amperage breakers allowed.

P2 construction features:
• Either 250A or 600A max. main bus, both Temp Rated and A/Si (Amps per Square inch) Rated bus
are available.
• Up to 600 volts AC with standard Bus bracing up to 200KAIC

Main space:
• 250A max. bus allows for MLO (125A or 250A) and Main Breaker Types BL/BQD, 3VA41/xGB,
QR or 3VA52/61/62 for 100-250A max. panel rating.
• 600A max. bus allow for MLO (max. 400-600A) and Main Breaker Types 3VA53/63 (400A max) or
3VA54/64 (600A max.) See SpeedFax for other Legacy breaker types if needed.

Unit space:
• Strap kits for 1” frame breakers can be mixed in unit space as needed. (Each kit uses 3” of unit
space)
- BL/BQD kits also accept GFCI/AFCI Breakers, BT twin and BPSD surge protection devices.
- 3VA41/xGB kits also accept BSPD surge protection devices
• Strap kits for larger frame breakers require 6” of unit space and are single mount for P2 panels.
- QR kits are 225A max. and 240V max.
- 3VA52/61/62 kits are the most versatile and are 250A max. and 600V max. with many optional
accessories available.

Subfeed space:
a) Feed-Thru Lugs either 250A max or 400-600A max are available.
b) Subfeed Breakers are no longer available in P2 panels since 250A max. branch breakers now fit in
unit space.

Additional information:
For complete application and pricing information contact your local sales office.

For further information on the product, visit our website at www.usa.siemens.com/panelboards.

For detailed configuration information consult the SpeedFax section 11 on the website.
P2 Panelboards 3

P2 Panelboard additional information

Enclosures available:
• Std. Enclosure sizes: 20” wide x 5.75” Deep
• Std. heights: 26”, 32”, 38”, 44”, 50”, 56”, 62”, 68” and 74”. Also available B74FLR universal fit
Type 1 Enclosure fits all P1/P2 interiors 26” thru 74”.
• Std. Types Available: Type 1, Type 3R, Type 3R/12, or Type 4X

Type 1 Fronts — Surface or Flush available:


Order to match box height: Typical 20” wide w/ #14 Gauge Steel

• FasLatch Front (Surface or Flush) is Standard, options available: Screw-to-Box, Hinge-to-Box


and Door-in-Door fronts with either standard hinge or Piano Hinge options (including 304
Stainless). [many of these fronts are also available for 24" wide enclosures when needed for
P1-P2 applications]

Weight = Approximate 3 lbs. per inch of box height (3.2 lbs/inch for 24" wide)
• Total panelboard weight when filled with a normal quantity of breakers and accessories is an
estimate only.

Series Connected Short Circuit Ratings


The term “Series Connected Short Circuit Rating” refers to the application of series connected
circuit breakers in a combination that allows some breakers to have lower individual interrupting
ratings than the available fault current.

This is permitted as long as the series combination has been tested and certified by UL. See
Circuit Breaker Section of the SpeedFax.

• Series rating booklet # PBTA-00101B-1020 (web searchable)


4 P2 Panelboards

Catalog Numbering System: Factory Assembled ) P 2 C 4 2 M L 2 5 0 A T S Typical Voltage Codes

Type of Panel: P 2 A 120/240 1: 3 W AC

Voltage and System Code: A, C, D, E, C 208Y/120 3: 4 W Wye AC

(additional codes in SpeedFax) F, J, I, T D 240 3: 3 W Delta AC

Circuits: 18, 30, 42, 54, 66, 78, 90 E 480Y/277 3: 4W Wye AC


(See Speedfax for MB Codes) Main: ML = Main Lug, F 480 3: 3 W Delta AC
“xx” = Main Breaker J 240 1: 2W No Neutral AC
Panel Amperage: 100-600A I 347 3: 3W Delta AC
Bus Code: (material/plating) A, B, E, F, G or H
T 230 3: 3W Delta AC
Feed Location: T = Top B = Bottom
See SpeedFax for additional
Note:
Mounting: S = Surface F = Flush Voltage codes available.

Small Frame Branch Circuit Breakers (also see Bolt on SPD series BSPD in this flier # RPFL-BSPD1-0120)
1-Pole 2-Pole and 3-Pole
P2 Small Frame Branch
Circuit Breakersa Max IR (kA) at Max IR (kA) at
Amp 125/
Amp Trip Breaker Breaker 125V Ratings 120/ 480Y/ 600Y/ 250V 250V Amp Ratings
Rating Type Family Type 120V 277V 347V DCd Available 240V 240V 277V 480V 347V 600V DCd DCd Available

BL, BTj 10 — — — 15-70j 10 10 — — — — — — 15-100f

Thermal
BL BLH, BTHj 22 — — — 15-70j 22 22 — — — — — — 15-100f
Magnetic

HBL 65 — — — 15-50 65 65 — — — — — — 15-100

100 BLGs 10 — — — 15-20 10 - — — — — — — 30


Specials BLG
Application BL
BL(HID)s 10 — — — 15-30 10 - — — — — — — 15-30

BQD BQDg 65 14 — 14 15-100 — 65 14 — — — 14 — 15-100


Thermal
BQD
Magnetic
(CSA) BQD6h 65 — — 14 15-70 — 65 — 10 — 14 — 15-70
AFCI/GFCI see special see special
Electronic
XX BL & Dual X — — — table page x — — — — — — — table page
and misc.
Function SF 11-17 SF 11-17
NGB 100 25 14 14 15-125 — 100 25 — 14 — 14 — 15-125

GB HGB 100 35 14 14 15-125 — 100 35 — 14 — 14 — 15-125

LGB 100 65 14 14 15-125 — 100 65 — 14 — 14 — 15-125


Thermal
125
Magnetic
SEAB 65 25 14 14 65 65 25 25 14 — 50 50 15-125

3VA41d MEAB 85 35 18 25 85 85 35 35 18 — 85 85 15-125

HEAB 150 65 25 30 150 150 65 65 25 — 100 100 15-125

a Unit space is 1 inch per pole, except for Special Application with accessory included. f 110A-125A BL/BLH (2-pole only) available as Main or Subfeed in
s BLG: Two-pole breaker is one phase and neutral. Three pole is two phases and neutral Revised P1 panels only.
- See SpeedFax Section 7 for additional info. Some are Built to order. Allow 2-3 weeks delivery. g Approved for CSA and UL Listed.
d DC Voltage Systems are not approved for use in P1 panels. Refer to P2/P3 panels if DC Voltage Systems are h Approved for CSA but not UL Listed.
needed. j BT and BTH are only available in 15A and 20A with two 1-pole cir-
cuits in one inch of unit space.
P2 Panelboards 5

Primary Main Breaker Selections available for P2 Panels


Note: all 250A and 225A frame are also suitable for single Horizontal mount in Unit Space.
2-Pole and 3-Pole
P2 Main Circuit Breakers & Unit Space (up to 250A max.) a Max IR (kA) at
Amp

480Vh

600Vj
/277V

/347V
240V

480Y

600Y
Amp Breaker Main Breaker Breaker Ratings Branch Strap Kits d
Rating Family Code Type Available (not for use as Main Kit)
BL BL 10 — — — — 15-100
100 BL BH BLH 22 — — — — 15-100 BBKB32
(Horiz. for 1-ph or 3-ph
only) HB HBL 65 — — — — 15-100 3” of unit space
BQD BQ BQDs 65 14 — 10 — 15-100

NB NGB 100 25 — 14 — 15-125


Sentron
G2 HGB 100 35 — 14 — 15-125
GB
125 G3 LGB 100 65 — 14 — 15-125 BBKVA4P2P3
(Horiz. for 1-ph or 3-ph
only) V1 SEAB 65 — 25 14 — 15-125 3” of unit space
3VA41 V2 MEAB 85 — 35 18 — 15-125

V3 HEAB 100 — 65 25 — 15-125

QR QR2 10 — — — — 100-225
225f BBKQR1
(Horiz. Sentron Q4 QRH2 25 — — — — 100-225 for 1-ph or 3-ph
or vert. QR Q5 HQR2 65 — — — — 100-225 6” of unit space
mount) Single mount Branch
Q6 HQR2H 100 — — — — 100-225

VA MFAS 85 — 35 — 18 100-250
3VA52
VB HFAS 100 — 65 — 25 100-250
(W/TM230 trip)
BBKVA5262P2S
250f VC CFAS 200 — 100 — 35 100-250 for 1-ph or 3-ph
[150]
6” of unit space
(Horiz. WA [W2] MFAE [MDAE] 100 — 35 — 18 100-250 [40-150]
Single Mnt. kit with
or vert.
3VA62 [3VA61] WB [W3] HFAE [HDAE] 100 — 65 — 22 100-250 [40-150] Hardware kit #
mount)
(ETU350 LSI BBKVA5262P2HW
standard) WC [W4] CFAE [CDAE] 200 — 100 — 35 100-250 [40-150]

WD [W5] LFAE [LDAE] 200 — 150 — 50 100-250 [40-150]

VE MJAS 85 — 35 — 18 200-400
3VA53
VF HJAS 100 — 65 — 25 200-400
(W/TM230 trip)
VG CJAS 200 — 100 — 35 300-400 Vertical Main only
Not available as
400 g
WE MJAE 100 — 35 — 18 100-400 Field Branch Kit
- Not available for
3VA63 WF HJAE 100 — 65 — 22 100-400 Subfeed
(ETU350 LSI
standard) WG CJAE 200 — 100 — 35 100-400

WH LJAE 200 — 150 — 50 100-400

VJ MLAS 85 — 35 — 18 450-600
3VA54
VK HLAS 100 — 65 — 25 450-600
(TM230 std)
VL CLAS 200 — 100 — 35 450-600 Vertical Main only
Not available as
600 g
WJ MLAE 100 — 35 — 18 160-600 Field Branch Kit
- Not availabe
3VA64 WK HLAE 100 — 65 — 22 160-600 for Subfeed
(ETU350 LSI
standard) WL CLAE 200 — 100 — 35 160-600

WM LLAE 200 — 150 — 50 160-600

a See Branch Strap Kit column for Field installable kits.


s Approved for CSA and UL Listed.
d Kits for unit space can be mixed as needed for application and re-arranged
in the field.
f QR and 3VA52/61/62 can be used as Main or Branch. Branch requires strap
kit for single mount in 6” of unit space. Adding in the field one of these
Strap kits may require adjusting the Deadfront Center strip. See DFK1 and
other lengths (DFK07 thru DFK21) in SpeedFax as needed.
g 3VA53/63 and 3VA54/64 can be used as Vertical Main only.
h 480V values apply to 480Y/277V also.
j 600V values apply to 600Y/347V also.
6 P2 Panelboards

Standard Enclosures
Catalog Number
Box
Height Type 1 Standard Trim
(in.) Boxa Surfaces Flushs Type 3Rd Type 3R/12d

26 B26 S26B F26B NR26 WP26

32 B32 S32B F32B NR32 WP32

38 B38 S38B F38B NR38 WP38

44 B44 S44B F44B NR44 WP44

50 B50 S50B F50B NR50 WP50

56 B56 S56B F56B NR56 WP56

62 B62 S62B F62B NR62 WP62

68 B68 S68B F68B NR68 WP68

74 B74 S74B F74B NR74 WP74

a 14 Gauge Steel only.


s 16 Gauge Can w/ 14 Gauge Front.
d (UL approved construction. 16 Gauge Steel Can with 14 Gauge front or similar
approved construction.) A60 Galvanneal with ANSI 61 light gray paint is standard.

Surface Flush Surface Flush


Box No. of Box No. of
Size A A Hinges Size A A Hinges
26 26 27.5 2 56 56 57.5 3
32 32 33.5 2 62 62 63.5 3
38 38 39.5 2 68 68 69.5 3
44 44 45.5 3 74 74 75.5 3
50 50 51.5 3
P2 Panelboards 7

Type 1 Box
Box is symmetrical

0.313 in. Dia.

0.313 in. Dia.

³⁄₄ in. 20 in. ³⁄₄ in.


[19 ] [ 508 ] [19 ]

5.75 in.
[ 146 ]

(UL approved construction. 16 Gage Steel or equivalent alternate Construction.


14 or 12 Gage is available as an optional special order.)
G60 Galvanized is standard without paint.

Type 3R and 3R/12 Box 8.0 in. Flush Mounting


Note: 3R boxes 50" High and Larger include two "T" handles. [ 204 ]

8.0 in.
[ 204 ]
ting Holes (Mounting Holes
n. Square) 0.437 in. Square)

(Mounting Holes (Mounting Holes


0.437 in. Square) 0.437 in. Square)

idth = 12.97"

(UL approved construction. 16 Gage Steel Can with


Door width = 12.97" 14 Gage front or similar approved construction.)
A60 Galvannealed with ANSI 61 light gray paint is
standard.

nting Holes (Mounting Holes


in. Square) 0.437 in. Square) Dimensions are interior of the box. Add 5/8” to
width for absolute dimension. Add 1/8” to height for
absolute dimension.
(Mounting Holes (Mounting Holes
0.437 in. Square) 0.437 in. Square)
Dimensions shown in inches and millimeters [ ].

23.0 in.
[ 584 ]

23.0 in.
[ 584 ]
Legal Manufacturer This document contains a general
description of available technical options
Siemens Industry, Inc.
only, and its effectiveness will be subject to
3617 Parkway Ln
specific variables including field conditions
Peachtree Corners, GA 30092
and project parameters. Siemens does not
United States of America
make representations, warranties, or
Telephone: +1 (800) 333-7421 assurances as to the accuracy or
www.usa.siemens.com/panelboards completeness of the content contained
herein. Siemens reserves the right to
Order No. PBSS-20302-1021
modify the technology and product
© 10.2021, Siemens Industry, Inc.
specifications in its sole discretion without
advance notice.

You might also like