CP Circuit Protection
CP Circuit Protection
Circuit Protection
®
FREE Videos:
www.automationdirect.com/videos
FREE Documentation:
www.automationdirect.com/documentation
Fuji Electric
UL 489 Rated Molded Case Circuit Breakers
(MCCBs)
BW Series Fuji Molded Case Circuit Breakers are more compact
(especially 100A, 125A, 250A frames) than any breakers on the market,
so control panels take up less space than ever before. This product
group maintains conformity to all Worldwide standards, including
cULus / IEC / CE Marking / JIS (Japan) / CCC (China).
• Suitable for branch circuit protection
• 5 frame sizes, rated current of 15 to 800A, max 600V
starting at • Standard type and high-interrupting capacities are available in identically
$182.00 sized breakers
• Shunt Trip, Undervoltage Release and other accessories are available
• Auxiliary Switch and Shunt Trip can be installed in the field
Main Circuit
• 10kAIC @ 277/480VAC Motor feeder
short circuit
disconnecting
means
(NEC 430.101-
Molded Case Current Manual Motor 430.113)
Load Supplementary General
and DIN rail Limiting Disconnect Starters
Switches Protectors Fuses
mounted UL489 Fuses Switches (MMS) Motor branch-
UL 508 UL 1077 UL 248 circuit short
Circuit Breakers UL 248 UL 98 UL 508
circuit protection
(NEC 430.51-
430.58)
Short circuit for feeder
and branch circuits YES YES YES NO NO NO NO
Motor controller
Motor Circuit
Motor branch-circuit
short circuit protection YES YES YES NO NO NO NO Motor overload
(NEC 430.51-430.58) protection (NEC
430.21-430.44)
Motor controller
(NEC 430.81-430.91) YES YES YES NO NO NO NO
OSHA Lockout/
Motor overload tagout
protection YES YES YES YES NO NO NO disconnect
(NEC 430.21-430.44) (NEC 430.81-
430.91)
OSHA Lockout/tagout
disconnect YES YES YES YES YES NO NO
(NEC 430.81-430.91) Mot or
Protection Selection We carry industry standard current limiting class CC, general
purpose class M (Midget) and small dimension glass and ceramic
Supplementary General circuit protection, fuse holders and accessories.
Protectors Fuses
Control
UL 1077 UL 248-14 They provide ideal supplemen-
starting at
Transformer
tary protection up to 30 amps
$2.00 to branch circuits and end of
for 5-pack
line equipment.
Anywhere
branch
circuit,
YES YES overcurrent
protection is
already provided
PLC Contactor Relays or not needed
I/O Coils
starting at
$9.25 starting at
$8.50
UL489 or UL1077?
What are your Circuit Protection Requirements?
An understanding of circuit types and circuit protection products is critical to ensure their proper application.
See NEC Sections 100, 430 and 409 for definitions.
The proper sizing of an overcurrent protection device is the responsibility of the customer and should be determined using the
application standards of the NEC (National Electric Code), CEC (Canadian Electrical Code) or other
applicable standards. Per fine print note of 2008 NEC Section 100 “A current in excess of rating may be
accommodated by certain equipment and conductors for a given set of conditions. Therefore, the rules for
overcurrent protection are specific for particular situations.”
UL489 UL1077
Branch Protection Supplementary Protection
•O pens automatically on Overload and Short Circuit when properly • Opens automatically on Overload and Short Circuit
applied within its ratings • Provides additional equipment protection where branch circuit
• Protects wire and cable against Overload and Short Circuit protection is already provided or not required
• Not suitable for the protection of branch circuit conductors
Applications
• B ranch circuit protection in control panels, panelboards, switchboards • circuits,
Used within appliances or other electrical equipment such as control
control power transformers, relays, PLC I/O points and
and motor control centers lighting circuits
•M otor overload and motor short circuit protection (UL489 Recognized • I
deal replacement for fuses that are applied as supplementary
motor circuit protectors) for control panels and motor control centers protection
Features
• Bolted down or DIN-rail mounted • DIN-Rail mounted
• External handle mechanisms available • Field mounted accessories
• Field mounted accessories • Various levels of protection (curve type)
• Stand alone branch circuit protection • 10 kAIC @ 240 VAC
• Various levels of protection (curve type) • 10 kAIC @ 277 VAC and 5 kAIC @ 480VAC
• High voltage and interruption levels (up to 100 kAIC @ 480V) • 10 kAIC @ 48VDC
kAIC = thousands of Amps interrupt capacity
Summary
A Supplementary Protector can’t be used for Branch Circuit Protection.
Understanding the difference between Branch Circuit Protection and Supplementary Protection helps to ensure their proper use.
UL 489
Breaker
UL 489
UL1077 Branch External
Internal Receptacle Receptacle
Electronics
UL1077 UL 489
Branch External
Motor
Other
Sensitive M
Devices
UL 489
Branch External
Motor
UL 489
Branch M
Note: UL489 devices can be used in place of UL1077; UL1077 devices cannot be used in place of UL489.
BW125JAGU-3P125SB shown
10
6
4
2 Max. value
1
40
20 BW125 (rated current 15A)
10
Operating time
0.2
Rated current
0.1 Instantaneous tripping
100
0.06 characteristic
0.04 500A±100A
0.02
0.01 50
1 1.5 2 3 4 5 6 78 10 15 20 30 405060 80100 10 0 10 20 30 40 50
180
120
60
40
Minute
20
BW125 Rated Current 20A
10
6
4
2
1
Max. value BW125 (rated current 20A)
40
20
Reference temp. 40˚C
10
Operating time
150
6 Max. total fault
4
correction ratio (%)
clearing time
Min. value
2
Rated current
1 100
0.6
0.4
Second
Rated current
0.1 characteristic
100
0.06 500A±100A
0.04
0.02
0.01 50
1 1.5 2 3 4 5 6 7 8 10 15 20 30 40506080100 10 0 10 20 30 40 50
180
120
60 BW125 Rated Current 40A
40
20
Minute
10
6
4
2 Max. value
1
40 BW125 (Rated current: 40A)
20
10
Operating time
20
10
6
4
2 Max. value
1 BW125 (Rated current: 50 - 125A)
40
20
Operating time
10
6 Max. total fault
4 Min. value clearing time
2
1 Reference temp. 40°C
150
0.6
0.4
Second
BW250JAGU-3P125SB shown
10
6
4
2 Max. value
BW250 (Current Range: 125 - 250A)
1
40
20
10
Operating time
6 Min. value
4 Max. total fault
clearing time
2
1 Reference temp. 40˚C
150
0.6
0.4
Second
Instantaneous
0.2
tripping
Rated current
BW400SAGU-3P250SB shown
20
10
6
4
2 Max. value
1 BW400 (Current Range: 250 - 400A)
40
20
Operating time
10
6 Min. value
4 Max. total fault
2 clearing time
1 Reference temp. 40˚C
0.6 150
0.4
Second
0.2 Instantaneous
tripping
Rated current
0.1
0.06 characteristic 100
0.04 10 In±20%
0.02
0.01 50
1 1.5 2 3 4 5 6 78 10 15 20 30 40506080100 10 0 10 20 30 40 50
Multiple of rated current Ambient temp. (˚C)
BW630RAGU-3P500SB shown
20
10
6
4
2 Max. value
10
6 Min. value
4 Max. total fault
clearing time
2
1
0.6 Reference temp. 40˚C
0.4
Second
150
Instantaneous
0.2
tripping
Rated current
0.1 characteristic
0.06 10 In±20% 100
0.04
0.02
0.01 50
10 0 10 20 30 40 50
1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 5060 80 100
Multiple of rated current Ambient temp. (˚C)
Fuji BW800A series MCCBs are 800 amp applications. Included with each MCCB
frame, 3-pole, non-adjustable magnetic trip, are Line and Load-side lug terminals and
molded case circuit breakers (MCCB). The mounting hardware. Accessories are not
BW800 series is suitable for reverse feed pre-installed and are sold separately.
BW800RAGU-3P700SB shown
alue
Fuji Molded Case CircuitBW800Breakers –
(Current Range: 700 - 800A
800A Frame Characteristic Curves
Max. total fault
clearing time
Operating time
eristic
0% 100
50
3 4 5 6 7 8 10 15 20 30 40 5060 80 100 10 0 10 20 30 40 50
15 to 125A
BW125A Frame
125 to 250A
BW250A Frame
250A to 350A
BW400 Frame
400A
BW400 Frame
500A to 600A
BW630 Frame
700A
BW800 Frame
800A
BW800 Frame
BW9FRG0 Shunt Trip 24 VAC/VDC (Mounting both Left and Right sides) X X
BW9FHA-R Shunt Trip 24-48 VAC/VDC (Mounting Left side ONLY) X X X
Shunt Trip 100-120 VAC, 100-110 VDC
BW9FAG0 (Mounting both Left and Right sides) X X
BW9FHA-A Shunt Trip 100-280 VAC, 100-220 VDC (Mounting Left side ONLY) X X X
BW9F0CA-15A Flange Handle (flex shaft), NEMA 12, 59“ (1.5m) cable,
125 Amp frame X
BW9F0CA-20A Flange Handle (flex shaft), NEMA 12, 78.7” (2.0m) cable,
125 Amp frame X
Flange Handle (flex shaft), NEMA 12, 59“ (1.5m) cable,
BW9F0GA-15A 250 Amp frame X
Flange Handle (flex shaft), NEMA 12, 78.7” (2.0m) cable,
BW9F0GA-20A 250 Amp frame
X
Flange Handle (flex shaft), NEMA 12, 59“ (1.5m) cable,
BW9F0HA-15A 400 Amp frame
X
Flange Handle (flex shaft), NEMA 12, 78.7” (2.0m) cable, 400 Amp
BW9F0HA-20A frame X
Nema 12 flexible shaft handle for 630A or 800A frame. 59.06”
BW9F0JA-15A (1.5m) cable
X X
Nema 12 flexible shaft handle for 630A or 800A frame. 78.74” (2m)
BW9F0JA-20A cable X X
Handle
Undervoltage trip
BW9V0CA shown
Rotary Operating Handles for Fuji MCCBs – Selection Guide
With the optional shaft With the optional shaft
V-type Handle (x= 6.102 (155)) V-type (x= 24.567 (624))
Breaker V-type Mounting Handle
Price Max. Mounting Range in which the Max. Mounting Range in which Screw Mass
Type Handle
H: inch(mm) Depth hinge with H can Depth the hinge with H lb. (kg)
H: inch(mm) be installed H: inch(mm) can be installed
BW125 BW9V0CA $45.00 4.134±0.078 9.843±0.078 5.512 to 9.843 28.307±0.078 28.307 - 5.591 M4 x 3.35 (85) 1.48 (0.67)
BW250 BW9V0GA $45.00 (105±2) (250±2) (140 to 250) (719±2) (124 - 719)
Dimensions Notes: • Handle is an operating mechanism only; not for sealing enclosure door.
• Not available for side mounting
Units: inches [mm] • For BW250 Series only: When mounting a terminal cover, cut away part of it because it hides
the mounting screws for the breaker.
4.449 (113)
Panel
Line C
L MCCB
2.677 (68) Door panel cutting
Handle
4-0.591 dia (ø15) C/L
4.449 (113)
MCCB 0)
3.071 (78)
MCCB (ø9
dia
handle Handle C/L 43
3.5
C/L
3.071(78)
Load Panel thickness: Note: Align the center of the hole cut in the panel
0.047 to 0.126 (1.2 to 3.2) 28.87
with the center of the breaker handle. (733.4)
C 2.559 (65) H
L
1.929 (49)
Handle C/L
Padlock size 0.157 dia to 0.315 dia (ø4 to ø8)
.94
4P 3P 2P (24.0)
1.181 (30)
Optional shafts
1.929 (49)
BW9VSG0
1.614
(41)
X = 6.102 (155)
BW9VSG0-24
X = 24.567 (624)
1.063
(27)
0.315 (8)
0.039 (1)
0.591 (15)
Dimensions
Units: inches [mm]
5.906 (150)
Door panel cutting
Line
)
10
(ø
4.409 (112) d ia
Panel Decorative 94
0.3
plate 4-
5.906 (150)
4.409 (112)
8)
ø13
MCCB ia ( MCCB
3 3d
handle C/L 5.4 handle C/L
OFF
5.906 (150)
MCCB
Mounting
screw handle C/L
can be mounted.)
10.37
Optional shafts (263.5)
2.165 (55)
BZ-VS2
X = 3.504 (89)
BZ-VS2-24
X = 24 (609.6)
1.181 (30)
BW9F0JA-20A shown
BW630*& BW9F0JA-15A $388.00 Nema 12 flexible shaft handle for 630A or 800A frame. 59.06” (1.5m)cable
BW800* BW9F0JA-20A $399.00 Nema 12 flexible shaft handle for 630A or 800A frame. 78.74” (2m) cable
*Terminal covers for line side and load side included with Flange Disconnects. 2/pk
Frame Size 125A frame 250A frame 400A frame 630A/800 frame
Mechanical Endurance 10,000 8,000 6,000 6,000
(cycles)
Ambient Temperature 14 to 140F (- 10 to 40°C)
Relative Humidity less than 95% RH
Protection NEMA Type12 IP54 (IEC60529)
Conforming Standards NFPA 79(2007), ANSI(Lockout), OSHA(1910.147, Lockout/tagout), UL489(cUL)
Environment No excessive dust, smoke, corrosive gases, flammable gases, steam or salt.
BW9F0CA
BW9F0GA
BW9F0HA
BW9F0JA
BW400
BW630 BW9W1SHA $22.50 Auxiliary switch for for 400A , 630A and 800A frame. Mounting left side ONLY
BW800
Ratings of Auxiliary Switches
Standard Type
Rated Make/Break Current (A)
Minimum
Breaker Type Thermal AC DC Load Current
Current (A) Voltage (V) Res. Load Ind. Load Voltage (V) Res. Load Ind. Load
24 5 5 24 4 3
BW125, BW250, 48 5 5 48 2.5 1 5V DC 160 mA
BW400 BW630, 5
BW800 125 5 3 125 0.4 0.4 30V DC 30 mA
250 3 2 250 0.2 0.2
Shunt Trips
Shunt Trip is for remote tripping (opening) of crircuit breaker.
BW400*2 24 2 24 2
BW630*2
BW800*2 120 - 130 3 125 3
Replacement Lugs
Terminal Covers
Terminal covers act as guards to shield the
operator from touching live terminations.
They fit either the line or load side.
BW9BTHA-L3W
Terminal Covers for Fuji MCCBs – Selection Guide shown
Dimensions inch (mm)
Breaker Type Part Number Price Description
A B C
A C
Breaker
Lockout Attachment
Note: These parts available for sale to North American locations only.
Amp Rating
3 Pole
100,000
20,000
30,000
40,000
50,000
60,000
70,000
80,000
90,000
10,000
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
200
300
400
500
600
700
800
900
50
60
70
80
90
10,000 10,000
Circuit Breaker Time/Current Curves
2 HOURS
2 HOURS
1 HOUR
rated wire (60/75˚C) per terminal. Tested in open air with
1 HOUR
2,000 2,000
M ax im um Vo lts
Breaker AC Volts
Type 60 Hz
G 3P 480
1,000 1,000
100 100
1 MINUTE
1 MINUTE
50 50
30 30
20 20
10 10
M axim um
M inim um 5
5
3 3
2 2
TIME IN SECONDS
1 1
.5 .5
TIME IN SECONDS
.3 .3
.2 .2
.1 .1
.05 .05
.03 .03
.005 .005
.003 .003
.002 .002
.001 .001
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
200
300
400
500
600
700
800
900
10,000
20,000
30,000
40,000
50,000
60,000
70,000
80,000
90,000
100,000
50
60
70
80
90
10000
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
200
300
400
500
600
700
800
900
5 6 7 8 9 10 20 30 40 50 60 70 8090
10,000
Circuit Breaker Time/Current Curves
2 HOURS
2 HOURS
F3P 60 Amperes
5,000 5,000
1 HOUR
1 HOUR
Breaker Rating
1,000 Continuous Amperes Instantaneous Trip Amperes 1,000
60 Amps See Curve
F3P 65 35 18 10
300 300
200 1 Single pole test data at 25˚C based on NEMA Procedures 200
Maximum Single (AB 4-1991) for verifying performance of molded case circuit
Pole Trip Times breakers.
at 25°C 1
100 100
1 MINUTE
1 MINUTE
50 50
30 30
20 20
Minimum Maximum
10 10
5 5
3 3
TIME IN SECONDS
2 2
1 1
TIME IN SECONDS
.5 .5
.3 .3
.2 .2
.1 .1
.05 .05
.03 .03
.01 .01
Interrupting
.005 Rating .005
Determines
End of Curve
.003 (See Above) .003
.002 .002
.001 .001
10000
7000
500
1000
2000
3000
4000
5000
6000
8000
9000
700
200
300
400
600
800
900
100
5 6 7 8 9 10 20 30 40 50 60 70 8090
CURRENT IN AMPERES
10000
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
200
300
400
500
600
700
800
900
5 6 7 8 9 10 20 30 40 50 60 70 8090
10,000
Circuit Breaker Time/Current Curves
2 HOURS
2 HOURS
F3P 70 Amperes
5,000 5,000
1 HOUR
1 HOUR
Breaker Rating
1,000 Continuous Amperes Instantaneous Tr ip Amperes 1,000
70 Amps See Curve
F3P 65 35 18 10
300 300
200 1 Single pole test data at 25˚C based on NEMA Procedures 200
Maximum Single (AB 4-1991) for verifying performance of molded case circuit
Pole Trip Times breakers.
at 25°C 1
100 100
1 MINUTE
1 MINUTE
50 50
30 30
20 20
Minimum Maximum
10 10
5 5
3 3
TIME IN SECONDS
2 2
1 1
TIME IN SECONDS
.5 .5
.3 .3
.2 .2
.1 .1
.05 .05
.03 .03
Maximum Interrupting Time
.02 .02
.01 .01
Interrupting
.005 Rating .005
Determines
End of Curve
.003 (See Above) .003
.002 .002
.001 .001
10000
7000
500
1000
2000
3000
4000
5000
6000
8000
9000
700
200
300
400
600
800
900
100
5 6 7 8 9 10 20 30 40 50 60 70 8090
CURRENT IN AMPERES
10000
2000
3000
4000
5000
6000
7000
8000
9000
1000
100
200
300
400
500
600
700
800
900
5 6 7 8 9 10 20 30 40 50 60 70 80 90
10,000
Circuit Breaker Time/Current Curves
2 HOURS
2 HOURS
F3P 80 Amperes
5,000 5,000
1 HOUR
1 HOUR
Breaker Rating
1,000 Continuous Amperes Instantaneous Tr ip Amperes 1,000
80 Amps See Curve
F3P 65 35 18 10
300 300
200 Maximum Single 1 Single pole test data at 25˚C based on NEMA Procedures 200
Pole Trip Times (AB 4-1991) for verifying performance of molded case circui t
at 25°C 1 breakers.
100 100
1 MINUTE
1 MINUTE
50 50
30 30
20 20
10 10
5 5
3 3
Minimum Maximum
TIME IN SECONDS
2 2
1 1
TIME IN SECONDS
.5 .5
.3 .3
.2 .2
.1 .1
.05 .05
.03 .03
.01 .01
Interrupting
.005 Rating .005
Determines
End of Curve
.003 (See Above) .003
.002 .002
.001 .001
5 6 7 8 9 10 20 40 50 60 70 80 90
500
30
700
7000
200
300
400
600
800
900
1000
2000
3000
4000
5000
6000
8000
9000
10000
100
CURRENT IN AMPERES
10000
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
200
300
400
500
600
700
800
900
5 6 7 8 9 10 20 30 40 50 60 70 8090
10,000
Circuit Breaker Time/Current Curves
2 HOURS
2 HOURS
F3P 90 Amperes
5,000 5,000
1 HOUR
1 HOUR
Breaker Rating
1,000 Continuous Amperes Instantaneous Tr ip Amperes 1,000
90 Amps See Curve
F3P 65 35 18 10
300 300
200 Maximum Single 1 Single pole test data at 25˚C based on NEMA Procedures 200
Pole Trip Times (AB 4-1991) for verifying performance of molded case circui
t
at 25°C 1 breakers.
100 100
1 MINUTE
1 MINUTE
50 50
30 30
20 20
10 10
Minimum Maximum
5 5
3 3
TIME IN SECONDS
2 2
1 1
TIME IN SECONDS
.5 .5
.3 .3
.2 .2
.1 .1
.05 .05
.03 .03
.01 .01
Interrupting
.005 Rating .005
Determines
End of Curve
.003 (See Above) .003
.002 .002
.001 .001
10000
7000
500
1000
2000
3000
4000
5000
6000
8000
9000
700
200
300
400
600
800
900
100
5 6 7 8 9 10 20 30 40 50 60 70 8090
CURRENT IN AMPERES
10000
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
200
300
400
500
600
700
800
900
5 6 7 8 910 20 30 40 50 60 708090
10,000
2 HOURS
1 HOUR 2 HOURS
5,000 5,000
1 HOUR
For application and coordination purposes only
Based on 40°C ambient, cold start. Connected.
with four
3,000 (4) feet of rated wire (60°C up to 125 amps, 75°C 3,000
above 125 amps) per terminal
Tested in open air with current in all poles.
2,000 2,000
Maximum AC Volts: 600 at 60 Hz
Maximum DC Volts: 250
Breaker Rating
1,000 Continuous Amperes Instantaneous Trip Amperes 1,000
100 Amps See Curve
Interrupting Rating (UL/CSA Listed)
Breaker Symmetrical RMS Amperes (KA) Amps (KA)
500 @ 480 VAC @ 600 VAC @ 250VDC 500
Type @ 240 VAC
F3P 65 35 18 10
300 300
200 * Single pole test data at 25°C based on NEMA Procedures 200
Maximum Single
Pole Trip Times (AB 4-1991) for verifying performance of molded case circuit
at 25°C * breakers.
100 100
1 MINUTE
1 MINUTE
50 50
30 30
20 20
10 10
Minimum Maximum
5 5
3 3
TIME IN SECONDS
2 2
TIME IN SECONDS
1 1
.5 .5
.3 .3
.2 .2
.1 .1
.05 .05
.03 .03
.01 .01
Interrupting
.005 Rating .005
Determines
End of Curve
.003 (See Above) .003
.002 .002
.001 .001
5 6 7 8 9 10
10000
100
20 40 50 60 708090
7000
30
1000
2000
3000
4000
5000
6000
8000
9000
500
700
200
300
400
600
800
900
CURRENT IN AMPERES
10000
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
200
300
400
500
600
700
800
900
5 6 7 8 9 10 20 30 40 50 60 70 8090
10,000
Circuit Breaker Time/Current Curves
2 HOURS
2 HOURS
1 HOUR
1 HOUR
rated wire (60°C up to 125 amps, 75°C above 125 amps) per terminal.
Tested in open air with current in all poles. .
3,000 3,000
Breaker Rating
1,000 Continuous Amperes Instantaneous Trip Amperes 1,000
125 Amps See Curve
Interrupting Rating (UL/CSA Listed)
Breaker Symmetrical RMS Amperes (KA) Amps (KA)
500 Type @ 500
240 VAC @ 480 VAC @ 600 VAC 250 VDC
1 MINUTE
1 MINUTE
50 50
30 30
20 20
10 10
Minimum Maximum
5 5
3 3
TIME IN SECONDS
2 2
1 1
TIME IN SECONDS
.5 .5
.3 .3
.2 .2
.1 .1
.05 .05
.03 .03
.01 .01
.001 .001
10000
7000
500
1000
2000
3000
4000
5000
6000
8000
9000
700
5 6 7 8 9 10 20 40 50 60 70 8090
200
300
400
600
800
900
100
30
CURRENT IN AMPERES
10000
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
200
300
400
500
600
700
800
900
5 6 7 8 9 10 20 30 40 50 60 70 8090
10,000
2 HOUR S
2 HOUR S
¨
1 HOUR
For application and coordination purposes only.
Based on 40˚C ambient, cold start. Connected with four (4) feet of
3,000 rated wire (60˚C up to 125 Amps, 75˚C above 125 Amps) per terminal. 3,000
Tested in open air with current in all poles.
.
2,000 2,000
M ax im u m A C Vo l t s : 600 at 60 Hz
M ax im u m D C Vo l t s : 250
Breaker Rating
1,000 Continuous A mperes Instantaneous Trip Amperes 1,000
150 A m ps See Curve
100 100
1 MINU TE
1 MINU TE
50 50
30 30
20 20
10 10
M inim um M axim um
5 5
3 3
TIME IN SECONDS
TIME IN SECONDS
2 2
1 1
.5 .5
.3 .3
.2 .2
.1 .1
.05 .05
.03 .03
.01 .01
.002 .002
.001 .001
7000
1000
2000
3000
4000
5000
6000
8000
9000
5 6 7 8 9 10 20 30 40 50 60 70 8090
500
700
200
300
400
600
800
900
10000
100
1000
100
200
300
400
500
600
700
800
900
10
20
30
40
50
60
70
80
90
5 6 7 8 91 2 3 4 5 6 7 8 9
10,000
Circuit Breakers Time/Current Curves
2 HOURS
2 HOURS
1 HOUR
1 HOUR
Based on 40˚C ambient, cold start. Connected with four (4) feet of rated
wire (75˚C) per terminal. Tested in open air with current in all poles.
Maximum Single
Pole Trip Times Notes:
300 À Fixed Inverse Ð Time Overcurrent Release. 300
at 25˚C Á Á Single Pole Test Data at 25 ˚C based on NEMA Procedures (AB 4-1991)
for verifying performances of Molded Case Circuit Breakers.
200 Â Total Operation Time. 200
à Interrupting Rating Determines End of Curve.
In this interruption region:
The curve is drawn for I n = 200A. For I n ¹ 200A, the end points in this
region are displaced along the current-axis by a factor (200A/I n )
100 100
1 MINUTE
1 MINUTE
50 50
30 30
Maximum
Trip Time
20 20
10 10
5 5
3 3
TIME IN SECONDS
2 Minimum 2
Trip Time
1 1
TIME IN SECONDS
175 A
.5 .5
200 A
.3 .3
.2 225 A .2
.1 .1
.05 .05
.03 .03
Â
.02
à .02
.01 .01
.005 .005
.003 .003
.002 .002
.001 .001
1 2 3 4 5 6 7 8 9
1000
700
50
100
200
300
400
500
600
800
900
70
20
30
40
60
80
90
10
Note: See 3P Series Molded Case Circuit Breakers Accessories catalog pages for accessory electrical specifications. 3TA401K
C U R R E N T I N P E R C E N T O F B R E A K E R T R I P U N I T R AT I N G ( I n)
100,000
20,000
30,000
40,000
50,000
60,000
70,000
80,000
90,000
10,000
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
200
300
400
500
600
700
800
900
50
60
70
80
90
10,000 10,000
2 HOURS
C i r c u i¨ t B r e a k e r T i m e / C u r r e n t C u r v e s
2 HOURS
C a t a l o g Ty p e s K 3 P 2 5 0 - 4 0 0 A m p e r e s
5,000 5,000
1 HOUR
1 HOUR
F o r a p p l i c a t i o n a n d c o o r d i n a t i o n p u r p o s e s o n l y. B a s e d o n
3,000 3,000
40°C ambient, cold start. Connected with four (4) feet of
rated wire (60°C up to 125 amps, 75°C above 125 amps)
p e r t e r m i n a l . Te s t e d i n o p e n a i r w i t h c u r r e n t i n a l l p o l e s .
2,000 2,000
M axim um Voltage
600V., Ac (60 Hz)
250 V., Dc
1,000 1,000
B reaker Rating
R ated Am peres (In ) Ins tantaneous Trip A m peres
100, 125, 150, 500 to 1000% of tr ip unit rati ng
175, 200, 225, (See Figure B elow)
500 250, 300, 350, (Dc values are approxim ately 40% higher) 500
(250-400A) 400
Interrupting Rating (UL/CSA)
B r e a k e r R MS S ym A mperes A m peres
300 300
(125-225A) Ty p e @ 240 VAC @ 480 VAC @ 600 VAC @ 250 VDC
M axim um Single Pole
Tr ip Ti m es at 25°C? K3P 65,000 35,000 25,000 10,000
200 200
1 MINUTE
M inim um M axim um
1 MINUTE
50 50
30 30
20 20
7.5 7.5 7.5
C Thermal Pu sh to Tr ip
Typical Magnetic
Tr ip U nit Tr ip Un it
10 N am eplate 10 5 10 5 10 5
10
Magnetic Amps Cat.
Multiples Of I n (In) 40°C No.
5 5
Individual Po le
A djus tm ents
3 3
TIME IN SECONDS
1 1
.5 .5
±20% ±10%
10X
5X
.3 .3
.2 .2
.1 .1
.05 .05
.03 .03
.02 .02
M axim um Interrupting Tim e
.01 .01
.005 .005
Interrupting
Rating
.003 .003
Determines
End of Curve
(See Above)
.002 .002
.001 .001
20,000
30,000
40,000
50,000
60,000
70,000
80,000
90,000
100,000
60
50
70
80
10,000
90
500
700
7000
200
300
400
600
800
900
100
1000
2000
3000
4000
5000
6000
8000
9000
C U R R E N T I N P E R C E N T O F B R E A K E R T R I P U N I T R AT I N G ( I n) C urve No. S
Note: See 3P Series Molded Case Circuit Breakers Accessories catalog pages for accessory electrical specifications.
3TA603LDK
AWG Wire Range Specifications
Circuit Ampere Wire AWG Wire Range Metric Wire
Breaker Rating Type Range mm2
400 3/0 - 350 (2) 95 - 150
L-Frame 500 Cu/AI 3/0 - 350 (2) 95 - 150
600 400 - 500 (2) 185 - 240 UVH4LP08K
C U R R E N T I N P E R C E N T O F B R E A K E R T R I P U N I T R AT I N G ( I n)
100,000
20,000
30,000
40,000
50,000
60,000
70,000
80,000
90,000
10,000
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
200
300
400
500
600
700
800
900
50
60
70
80
90
10,000 10,000
2 HOURS
Circuit Breaker Time/Current Cur ves
2 HOURS
1 HOUR
F o r a p p l i c a t i o n a n d c o o r d i n a t i o n p u r p o s e s o n l y. B a s e d o n
1 HOUR
2,000 2,000
M aximum Voltage
600 Volts A C (50/60Hz.)
250 Volts DC
1,000 1,000
R a t e d A m p e r e s ( In) I n s t a n t a n e o u s Tr i p A m p e r e s
See figure below
500, 600 500 to 1000% of tr ip unit rati ng (D C values
are approxim ately 40% higher)
500 500
Interrupti ng R ati ng
B r e a k e r U L/CS A
M axim um Single Type R MS Sym. kA , 50/60 Hz. kA, DC
300 Pole Trip Tim es 240 V. 480 V. 600 V. 250 V.
300
at 25°C 1
200
L3P 65 35 25 10 200
IEC 947-2
M inim um M axim um R MS Sym. kA , 50/60 Hz. kA, DC
100 240 V., (U e) 380 V., (U e) 415 V., (U e) 250 V., (U e) 100
Icu Ics Icu Ics Icu Ics Icu Ics
1 MINUTE
1 MINUTE
L3P 65 17 40 10 40 10 10 3
50 50
U tilizati on Ca tegory A
U IMP = 8 kV
N am eplate 10 5 10 5 10 5
5 5
Individual Pole
3 3
A djus t m ents
TIME IN SECONDS
2 2
TIME IN SECONDS
±20% ±10%
10X
5X
1 1
.5 .5
A djus table M agnetic Trip
.3 .3
.2 .2
.1 .1
.05 .05
.03 .03
M axim um Interrupting Tim e
.02 .02
.01 .01
Interrupting Rating
Determines End of
.005 Cur ve (See Above) .005
.003 .003
.002 .002
.001 .001
20,000
30,000
40,000
50,000
60,000
70,000
80,000
90,000
100,000
60
50
70
80
10,000
90
7000
500
1000
2000
3000
4000
5000
6000
8000
9000
700
200
300
400
600
800
900
100
C U R R E N T I N P E R C E N T O F B R E A K E R T R I P U N I T R AT I N G ( I n)
GHMVD12B $73.25 NEMA 1/12 black rotary handle for G-Frame MCCB. Shaft length: 12”
FHMVD12B $73.25 NEMA 1/12 black rotary handle for F-Frame MCCB. Shaft length: 12”
HM1R12X $104.50 NEMA 4/4X black rotary handle for F-Frame MCCB. Shaft length: 12”
HM1R24X $118.25 NEMA 4/4X black rotary handle for F-Frame MCCB. Shaft length: 24”
KHMVD12B $106.50 NEMA 1/12 black rotary handle for K-Frame MCCB. Shaft length: 12”
HM3R12X $129.25 NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 12”
HM3R24X $143.75 NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 24”
LHMVD12B $122.50 NEMA 1/12 black rotary handle for L-Frame MCCB. Shaft length: 12”
HM4R12X $167.50 NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 12”
HM4R24X $176.50 NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 24”
HM1R12X
F0S06C $320.25 NEMA 1/12 flex shaft cable operator for G-Frame MCCB. Cable length: 6’
F0S03C F1S03C $320.25 NEMA 1/12 flex shaft cable operator for F-Frame MCCB. Cable length: 3’
F1S06C $347.25 NEMA 1/12 flex shaft cable operator for F-Frame MCCB. Cable length: 6’
F3S03C $381.00 NEMA 1/12 flex shaft cable operator for K-Frame MCCB. Cable length: 3’
F3S06C $403.25 NEMA 1/12 flex shaft cable operator for K-Frame MCCB. Cable length: 6’
F4S04C $437.25 NEMA 1/12 flex shaft cable operator for L-Frame MCCB. Cable length: 4’
F4S06C $504.50 NEMA 1/12 flex shaft cable operator for L-Frame MCCB. Cable length: 6’
A1X3PK
Auxiliary Contact Accessory Selection Guide
Part Number Price Description
A1X3PK $188.75 Field installable auxiliary contact for K-Frame MCCB, SPDT, 18” pigtail leads
A1X4PK $193.50 Field installable auxiliary contact for L-Frame MCCB, SPDT, 18” pigtail leads
Undervoltage Release
This product monitors a voltage (typically a line voltage) and trips the circuit breaker
when the voltage falls to between 70% and 35% of the solenoid coil rating. It consists
of a continuous rated solenoid, with a plunger and tripping lever mounted in a
plug-in module.
Note: The undervoltage release is a pre-installed accessory on G-Frame and F-Frame breakers.
GDIN
NEMA 12 Safety Door Hardware
Type C361 door interlocking safety handle kits are designed for use with AutomationDi-
rect 3P series MCCBs and flexible handle, when mounted in an SDN12, or equivalent,
enclosure. These handles secure the SDN12 enclosure, protecting against unauthor-
ized entry while the MCCB is in the ON position. Use them on enclosures with right
side flanges only and material thickness from 16 gauge through 3/16”. All mounting
hardware is included for enclosures up to 40” tall. The addition of the C361KR roller
kit is necessary for enclosures taller than 40” that require a 3-point latch. See SDN12
Handle
Enclosures section for enclosure specifications in OFF
position
Safety Door Hardware Selection Guide
Part Number Price Description
Handle length: 4”. Mounting hardware included for enclosures up to 40” tall. For Release
C361KJ4 $232.00 taller enclosures that require a 3-point latch, the C361KR (purchase separately) will Screw
also be needed.
Handle length: 6”. Mounting hardware included for enclosures up to 40” tall. For
C361KJ6 $243.75 taller enclosures that require a 3-point latch, the C361KR (purchase separately) will
also be needed.
Door Interlocking safety roller kit for use with the C361KJ4 and C361KJ6 safety
C361KR $52.50 handle kits when the SDN12 series enclosure is taller than 40 inches and 3-point
latching is required. Kit includes roller and all hardware.
Safety Handle
Note: The 1/4” x 1/2” standard mill rectangular locking bar is not supplied with these kits. The bar is
supplied with the enclosures.
shown on enclosure
Trip curves
• B [3-5 In] Captive Terminal
• C [5-10 In] Screws
DIN Rail
• D [10-20 In] Mounting
Operating Handle
with Trip Free
Design
Color Coded
Flag Indicator
Information
Printed on
Part Number Front and Side
for Quick
Information
IP20 Finger
and Back-of-hand
Protection
Overview
The Eaton FAZ supplementary protec-
tors are used to provide overcurrent
protection where branch protection (for
example, UL 489 MCCB) is already pro-
vided or not required. The units can be
installed as a component within, or as a
part of an appliance or a piece of elec-
trical equipment. Supplementary protec-
tors are ideal replacements for fuses that
are applied as a supplementary protec-
tor, i.e. in addition to branch protection
(if required). They are 35mm DIN-rail
mountable, utilizing spring clips. These
are standard protectors, recognized by
UL and CSA under UL 1077 and CSA
22.2. They are CE marked in accord- Features and Benefits Applications
ance with Low Voltage Directive (LVD)
• Dual rated for AC or DC Applications FAZ Supplementary protectors are
(73/23/EEC).
• Box terminals accept #18 to #4 wire recognized per UL 1077 and certified
(1 to 25mm2) for one wire connection or
Product Specification #18 to #8 for two wire connection. per CSA C22.2 No. 235 as a
Supplementary Protector and can be
The FAZ supplementary protector is a • Thermal magnetic overcurrent
protection: three levels, categorized by B, fully utilized per the NEC and CEC
dual-rated product for both AC and DC C and D curves in direct relation to Codes in that capacity. For international
supplies, in accordance with UL 1077 continuous rating of the device purposes, the entire FAZ family is CE
and CSA 22.2 standards and is marked B curve magnetic trip point: marked and in full conformity with the
with CE in accordance with the Low Volt- 3 to 5 times the rated current, applicable IEC standards for miniature
age Directive. With this dual standard typically used for computers and circuit breakers, EN/IEC 60898 and
electronic loads with very low inrush
product, you can include it in your de- currents (PLC wiring). IEC/EN 60947-2.
sign, knowing that in most cases wher- C curve magnetic trip point: Outside North America, they can be
ever your equipment is used, the prod- 5 to 10 times the rated current, used in both residential and industrial
uct will conform to the local UL, CSA or typically used for small transformers,
pilot devices, etc. applications as feeder and branch circuit
IEC (International) requirements.
D curve magnetic trip point: protective devices. In North America,
The supplementary protector is de- 10 to 20 times the rated current, most European Miniature Circuit
signed to be applied in conjunction typically used for transformers or Breakers are only UL recognized and CSA
with a branch circuit protector (if branch devices with very high inductive loads. certified as “Supplementary Protectors”,
protection is required) and can be a re- • Trip Free Design: Protector cannot be meaning they cannot be utilized as
placement for similarly applied fuses. Its defeated by holding the handle in the
“ON” position. feeder or branch circuit protective
advantage over fuses is that it is resetta- devices per the local electrical codes
• Module width of only 17.7 mm per pole
ble and the device’s status is easily and (2008 NEC 240.10 and CEC Part 1
clearly identified by the position of the • Color coded status indicator window – C22.1). This commonly restricts their
Red = ON or Green = OFF
handle and the flag indicator. use to applications where “closer”
• IP20 finger protection
In addition, you can select a device that protection is desired than that offered by
• 35mm DIN-rail mountable, utilizing a branch circuit protection device.
provides maximum reliability and ac- spring clip
curacy to fit various applications due to • Captive screws cannot be lost Eaton FAZ Supplementary Protectors are
the availability of a wide range of cur- • Suitable for reverse feed applications ideal for providing protection in many
rent ratings from 0.5 to 63 amperes in applications, including:
three overcurrent characteristic curves,
B, C and D. Listings • Control power transformers (D curve)
• Relays
• UL recognized under UL 1077
Category QVNU2 File E177451 • Contactor coils
• CSA 22.2, No. 235 File 204453 • PLC I/O points
• CE File LVD 2006/95/EC • Lighting circuits
• IEC/EN 60898 • Power supplies
• IEC/EN 60947-2 • Computers
• Electronic equipment
• Control circuits
Supplementary
Protector
UL1077
UL1077
M M
PLC Contactor Relays
I/O Coils
Supplementary protectors are not to be used in feeder circuits or motor circuits. Use them
only in applications where branch protection is already provided or is not required.
Influence of the mains system frequency on the tripping behavior IMA of the instantaneous release
Influence of the Mains Frequency
Mains Frequency ƒ (Hz) 16 2/3 50 60 100 200 300 400
IMA(ƒ) IMA(50Hz) [%] 91 100 101 106 115 134 141
Let-Through Current
Let-Through Energy
7200
3600 2 Tripping characteristic
1 acc. to EN 60898
2
1
3
0.5
0.2
5 7 9
0.1
0.05
4 B6 C 8
D
0.02
0.01
0.005
0.002
0.001
0.0005
1 2 3 4 5 6 7 8 9 10 15 20 30 40 50
I / IN
or or
ZIS-SPE-1TE-3
Lockout Attachment
FAZ or FAZ-NA Series
Busbar System
Without auxiliary contacts
BBUL Series Busbars for use with FAZ Series Supplementary Protectors
Description Rated Operational Current Qty Price
BBUL25-1P-1M57-SP Busbar, 1 pole, 57-position, 480VAC 1 $35.75
100A,
BBUL25-2P-2M56-SP Busbar, 2 pole, 56-position, 480VAC fed from end 1 $68.25
BBUL25-3P-3M57-SP Busbar, 3 pole, 57-position, 480VAC 1 $101.00
Busbar Accessories
Description
BBUL-EC-1 10 $9.75
Busbar end cover for use with 1-pole Eaton BBUL series busbar.
BBUL-EC-1-2 2 $4.00
BBEV-EC-3 10 $13.00
Busbar cover end for use with 2-pole and 3-pole Eaton BBUL series busbar.
BBEV-EC-3-2 2 $5.25
BBUL-TEPA-35-1 Busbar terminal lug, connects wiring to busbar system, for use with 1-pole Eaton BBUL 1 $11.50
BBUL-TEPA-35-3 series busbar, accepts 10AWG to 1/0 AWG copper wire, 115A, 1000V AC/DC. 3 $32.50
BBUL-TEP-35-1 Busbar terminal lug, connects wiring to busbar system, for use with 2-pole and 3-pole 1 $11.50
BBUL-TEP-35-3 Eaton BBUL series busbar, accepts 10AWG to 1/0 AWG copper wire, 115A, 1000V AC/DC. 3 $32.50
BBUL-EC-1 BBUL-TEPA-35-1
Single
Phase Cut to
length
OR
BBUL-TEP-35-1 L3 L1
L1 L2
Three L2 L3 L1 L2
Phase 57-SP L3 L1
5-3P-3M L11 L2 L3
L1 L2
BBUL2 L2 L3 L3 L1
L1 L2
L2 L3
L1
BBEV-EC-3 BBIP-5
Top
Side
FAZ Series
Bottom
Side May feed from
Top or Bottom side
4.11
Manual Trip
contact 4.xx in Alarm mode SEL
contact 1.xx in Auxilary mode TRIP
OFF ON OFF 4.14
1 N 1.11 4.11 1 N 1.11 4.11 1 N 1.11 4.12
4.14
Electrical Trip
FAZ-XAM002 4.12
FAZ-XAM002 Diagrams
FAZ-XHIN11-SP FAZ-XAA-C-xxx
FAZ Series
Miniature Circuit Breakers
Connection Diagrams Busbar Connection Diagrams
Single Pole Two-Pole Three-Pole Three-Pole Busbar Two-Pole Busbar Single Pole Busbar
1 1 3 1 3 5 L1 L1 L
L2 L2
L3
2 2 4 2 4 6
BBUL25-1P-1M57-SP
BBUL25-2P-2M56-SP
BBUL25-3P-3M57-SP
BBIP-5
BBUL-TEP-35-1 BBUL-TEPA-35-1
BBUL-EC-1 BBEV-EC-3
Operating
7200
2
Handle Calibration
3600
1 tripping characteristic with Trip Free Temperature
acc. to UL 489 / CSA 22.2 No. 235
Design UL / CSA
1200 1 conventional non-tripping current
Int= 1.0 I N (T=40 °C )
600
2 conventional tripping current
Rated Voltage
300 I t = 1.35 I N: t < 1 h (T=25 °C ) UL / CSA
3 3 2.0 I N : t = 12 - 120 s (T=25 °C )
120
60 Rated
instantaneous tripping Current
30 acc. to IEC 60898-1 Part Number
4 type C: 5 I N : t > 0.1 s
Tr ipping time t [sec]
10 3 10 I N: t < 0.1 s
2
1
0.5
0.2
4 5
0.1
4 5
0.05 C D
Captive Terminal
0.02
Screws
0.01
0.005
0.002
0.001
0.0005
1 2 3 4 5 6 7 8 9 10 15 20 30 40 50
Multiples of In
FAZ-NA Series
Technical Specifications
FAZ-NA Miniature Circuit Breakers – UL/CSA
C Curve D Curve
Short Circuit Trip Response 5 - 10 I n 10 - 20 I n
Current Range 0.5 - 40 A
0.5 - 32 A 277 / 480Y
Maximum Voltage Ratings 35 - 40 A 240VAC
UL / CSA Per pole 48VDC
2 poles in series 96VDC Max
Thermal Tripping Single pole
40°C
Characteristics Multi-pole
Short Circuit 1 pole 10kA
Note: 14 kAIC at select amperages
Ratings 2 pole B and C curves (15-25 A)
(@ maximum voltage) 3 pole D curve (13-20 A)
Rated Frequency 50/60 Hz
Agency Approvals UL File #E235139, CSA #204453
Note: To obtain the most current agency approval information, see the Agency Approval Checklist section
on the specific part number's web page.
FAZ-NA Miniature Circuit Breaker - IEC
C Curve D Curve
Short Circuit Trip Response 5 - 10 I n 10 - 20 I n
Current Range 0.5 - 40 A
Maximum Voltage 1 pole
Ratings - 2 pole / 3 pole 240/415 VAC
IEC/EN 60947-2 2 poles in series
Thermal Tripping Single pole
30°C
Characteristics Multi-pole
Interrupt Ratings (At Max Voltage) 15kA
Rated Frequency 50/60 Hz
General Specifications
Lifespan / Endurance M20,000 (1 operation = ON/OFF)
UL 489, CSA C22.2 No.5 = 40°C
Operating Temperature IEC 60947-2 = 30°C
Shock (UL 489) 10g 20-25 ms
Housing Material Nylon
Mounting Position Vertical
1 pole 0.3 lb (136g)
Weight 2 pole 0.6 lb (272g)
3 pole 0.9 lb (408g)
Wire Size
Ampere Rating Conductor Size
One wire 18 to 6 AWG (0.75 to 13mm²)
0.5 - 40
Two wires 18 to 10 AWG (0.75 to 5mm²)
Note: Eaton does not recommend the use of wire ferrules or crimping terminals. The wire gauges are
specified above and in the installation instructions included with each circuit breaker.
Tightening Torque
Conductor Size Tightening Torque
18 - 12 AWG 21 lb·in (2.4 N·m)
10 - 8 AWG 25 lb·in (2.8 N·m)
6AWG 36 lb·in (4.1 N·m)
80000 80000
70000 70000
60000 60000
50000 50000
40000 40000
C 20 6
C1
30000 5, 30000 C40
C1
C35
C13 C32
20000 C10 20000 C30
C8 7
C6 , C C25
15000 15000
C5
C4 10000
10000 C3
9000 9000
8000 8000
7000 7000
6000 6000
5000 5000
4000 4000
3000 3000
C2
C 1,5
2000 2000
1500 1500
1000 1000
900 900
800 800
700 700
C1
600 600
500 500
400
400
300
300 C 0.5
500
1000
1500
2000
3000
4000
6000
7000
8000
9000
5000
10000
500
1000
1500
2000
3000
4000
6000
7000
8000
9000
5000
10000
80000 80000
70000 70000
60000 60000
50000 0
50000
D2
40000 40000
D40
30000 16 30000
5, D D35
D1
D32
D 13 D30
D10
20000 20000
D8 D25
7
D6,D
15000 15000
D5
D4
10000 10000
9000 D3 9000
8000 D2 8000
7000 D 1.5 7000
6000 6000
5000 5000
4000 4000
3000 3000
D1
2000 2000
1500 1500
1000 1000
900 900
800 800
700 700
600 600
500 500
400 400
300 300
D0.5
500
500
1000
1500
2000
3000
4000
6000
7000
8000
9000
1000
1500
2000
3000
4000
6000
7000
8000
9000
5000
5000
10000
10000
Power Loss at In 1
Characteristic D 0.5
In [A] 1p 2p 3p
P[W] P[W] P[W]
0.2
0.5 1.6 3.2 4.8
1 0.8 1.5 2.3 4 5
0.1
1.5 1.0 2.1 3.1 4 5
2 1.0 2.1 3.1 0.05 C D
3 1.2 2.4 3.6
4 1.4 2.9 4.3 0.02
5 1.5 2.9 4.4
0.01
6 1.2 2.3 3.5
7 1.4 2.8 4.3 0.005
8 1.2 2.4 3.7
10 1.5 3.0 4.5 0.002
13 2.0 4.1 6.1
15 1.5 3.1 4.6 0.001
16 1.7 3.5 5.2
0.0005
20 1.8 3.7 5.5
25 2.6 5.1 7.7
1 2 3 4 5 6 7 8 9 10 15 20 30 40 50
30 2.7 5.4 8.1
32 3.1 6.2 9.3 Multiples of In
35 3.8 7.6 11.3
40 3.9 7.8 11.6
1.40
1.30
Load factor KT [I/In]
1.20
1.10
1.00
0.90
-20 -10 0 10 20 30 40 50
IL = Maximum Load
T = Ambient Temperature
IN = Rated Current in Amps
KT = Load Factor
ZNHK ZIHK-NA
Alarm/Aux Contact Auxiliary Contact
ZNHK* ZIHK-NA
Price $21.25 $16.50
Electrical Data
Contact function 2 Form C (one set changeover) (SPDT) 1 N.O. + 1 N.C. (DPST)
Rated voltage 230VAC / 110V AC/DC 600VAC / 230VAC / 120VAC
Frequency 50/60 Hz
Rated current 2A / 0.5 A 1.2 A / 2A / 6A
Rated thermal current Ith 60947-5-1 2A / 250VAC 6A / 250VAC
60947-5-1 Utilization category AC13 3A / 250VAC
Rated Utilization category AC15 2A / 250VAC
operational 0.5 A / 110VDC
current Ie Utilization category DC12 0.5 A / 110VDC 0.25 A / 220VDC
Rated insulation voltage UI 250VAC
Minimal operational voltage per Contact Umin 5VDC
Minimum operational current Imin 10mA DC 10 mA AC/DC
Rated peak withstand voltage Uimp (1.2/50µ) 2.5 kV 4kV
Conditional short-circuit current Ik w/ backup fuse 6A 1kA 1kA
Mechanical Data
Tripping indicator "electrical tripping" Blue/white –
Frame size 45mm
Mounting Onto FAZ-NA
Degree of protection, built-in IP40
Terminal protection Finger and hand touch safe according to BGV A3, OVE-EN 6
Terminals Lift terminals
Terminal capacity 20-18 AWG (0.75 - 2.5 mm²) 20-14 AWG (0.5 - 2.5 mm²)
Terminal screws M3 (Posidrive Z0 - Phillips)
Fastening torque of terminal screws 7 lb·in (0.79 N·m) Max. 10.6 lb·in (1.2 N·m)
*Voltage of the FAZ-NA circuit breaker is limited to 300V with contact installed.
or or
C2
FAZ-XAA-NA12-110V FAZ-XAA-NA110-415V
Price $30.00 $30.00
Electrical Data
Can be mounted onto FAZ-NA
12-110 VAC 110-415 VAC
Operational voltage range 12-60 VDC 110-230 VDC
Maximum inrush current 15A 2.1 A
Frequency 50/60 Hz
Mechanical Data
Frame size 45mm
Height 4.13 in (105mm)
Width 0.69 in (17.5 mm)
Weight 0.28 lb (127g)
Mounting Quick fastening with two lock-in positions on EN 50022
Degree of protection, built-in IP40
Terminal protection Finger and hand touch safe according to BGV A3, OVE-EN 6
Terminals Open mouthed/lift
Terminal capacity, one and two wires 18-10 AWG (0.8 - 5.3 mm²)
Agency Approval UL File # E257181, CSA 204453
Note: To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number's web page.
Lockout Attachment
Lockout Attachment
Part Number Description Weight Qty Price
Lockout attachment for Eaton FAZ-NA series supplementary protectors and 0.10 lb
ZIS-SPE-1TE-3 FAZ-NA mini circuit breakers, suitable to prevent unauthorized activation of a (45g) 3 $26.25
de-energized circuit, accepts lock shackles up to 9/32 in. (7.1 mm) in diameter
1
ZIS-SPE-1TE-3
3
Busbar Specifications
Description UL489 IEC/EN60947-2
Operating Voltage 480VAC 96VDC 240/415 VAC
Frequency 50/60 Hz n/a 50/60 Hz
Rated impulse withstand Uimp n/a 9.5 kV
Max Current - Ie Fed from End 80A @ 40°C 80A @ 30°C
Cross Section n/a 16 mm2
Agency Approval UL File #E257181
ZEK35-UL
P-3TE12SP
ZSVUL16-3
Top
Side
ZVBS-UL
Bottom
Side
FAZ-NA Series
May feed from Top or Bottom side
ZVBS-UL Busbar Shroud - covers for unused bus bar terminals, (10) 3-terminal covers per package $22.50
ZVBS-UL-5 Busbar Shroud - covers for unused bus bar terminals, (5) 3-terminal covers per package $12.00
ZEK35-UL – Specifications
Description UL489 IEC/EN60947-2
Operating Voltage 480VAC 96VDC 240/415 VAC
Frequency 50/60 Hz n/a 50/60 Hz ZEK35-UL
Rated impulse withstand - Uimp n/a 9.5 kV ZEK35-UL – Tightening Torque
Max Current - Ie 80A @ 40°C 80A @ 30°C Tested Cable Size Tightening
#2 - 14 AWG 2.5 - 35 mm 2 Acc. To Torque
UL 486A #14 AWG M 20 lb·in (2.3 N·m)
0.56 in 14mm UL 486B #8 - 12 AWG M 25 lb·in (2.8 N·m)
Agency Approval UL File # E307559 UL 486E #6 - 1 AWG 35 lb·in (4 N·m)
Note: To obtain the most current agency approval information, see the Agency
Approval Checklist section on the specific part number's web page.
4.11
Manual Trip
contact 4.xx in Alarm mode SEL
contact 1.xx in Auxilary mode TRIP
OFF ON OFF 4.14
1 N 1.11 4.11 1 N 1.11 4.11 1 N 1.11 4.12
4.14
Electrical Trip
4.12
ZNHK
ZNHK Diagrams
21
13
22 14
ZIHK-NA
Diagram
ZIHK-NA
FAZ-NA Series
Miniature Circuit Breakers
Connection Diagrams
2 2 4 2 4 6
FAZ-XAA-NA-xxx
ZSVUL16-xP-xTExSP
ZVBS-UL ZEK35-UL
Listings
Disconnect Switch
UL Class CC fuse version
Fuse Holder
• UL Listed under UL 98
File E339079, Guide WHTY Compartment Knob
Lockout Provision
• cULus 22.2, No. 4-04
File 339079, Guide WHTY7
• CE Compliant Circuit Marking
• RoHS Area
UL Class Midget fuse version Open Fuse
• UL Listed under UL 508 Indication Spade
File E222847, Guide NRNT Light Connection
• cULus 22.2, No. 14-05
• CE Compliant
• RoHS
®
Compact Fusible Switches
AC and DC Compact Fusible Switches
Compact Fusible Switch Specifications - AC Switches
Part Number Poles Max Fuse Voltage Fuse SCCR Agency Approvals HP Ratings Price
Ampacity Range Type
UL 98 Listed
CFS-1PCC30 90 - 600 VAC Class CC 200 kA cULus 22.2 No. 4-04 0.5 HP @ 120 VAC $21.25
1
UL 508 Listed
CFS-1PM30 90 - 240 VAC* UL Midget 10 kA* CULus 22.2 No.14-05 n/a $21.25
UL 98 Listed
CFS-2PCC30 90 - 600 VAC Class CC 200 kA 2.0 HP @ 240 VAC $43.50
Single-Pole 2
cULus 22.2 No. 4-04
30A
UL 508 Listed
CFS-2PM30 90 - 240 VAC* UL Midget 10 kA*
CULus 22.2 No.14-05
n/a $43.50
Note: The minimum enclosure size is 14 in. x 12 in. x 6 in. Minimum spacings are 2 inches over surface, 1 inch through air.
* Rating may be lower depending upon installed fuse. Refer to fuse specifications.
* Rating may be lower depending upon installed fuse. Refer to fuse specifications.
Three-Pole
General Specifications Recommended Fuse Types
Construction RoHS compliant, IP20 compliant with AC Voltage Class CC
10 AWG or larger wire
Edison Bussmann Gould Littlefuse
Operating Temperature -20 °C to 75 °C (-4 °F to 167 °F) HCLR KTK-R ATMR KLKR
Flammability Rating UL 94V0 HCTR FNQ-R ATQR KLDR
Frequency 50/60 Hz EDSS LP-CC ATDR CCMR
Padlockable Yes [4mm (0.16 in) shank]
Local Indication Yes AC Voltage Class Midget
Mounting 35 mm DIN Rail Edison Bussmann Gould Littlefuse
MCL KTK ATM KLK
One-Pole 0.22 lbs. (100g)
MOL BAF / BAN OTM BLF
Weight Two-Pole 0.43 lbs. (195g)
MEQ FNQ ATQ FLQ
Three-Pole 0.65 lbs. (295g) MEN FNM TRM FLM
®
Compact Fusible Switches
Motor Sizing - Compact Fusible Switches
Note: NEMA motors only (no IEC or Design B Energy Efficient). Minimum size if no more than 1 start / hour. Use Code Max Fuse Amperage in low to moderate
reverse / jog / plug applications. Use Heavy Start Fuse Amperage only if Code Max does not allow motor start up. For high reverse / jog / plug applications
or larger horsepower motors, Class J fuses are recommended. (Refer to time-current curves for specific applications.) Per NEC 430.52
®
Compact Fusible Switches
Compact Fusible Switches Dimensions
CFS-1P
CFS-2P
Replacing Fuses
4
2
Steps:
1. Turn Switch Off.
2. Turn fuse holder compartment knob counterclockwise.
3. Rotate fuse holder compartment knob up.
4. *Remove fuse and replace with appropriate type CC or Midget fuse.
*Note: Insert replacement CC fuse with rejection feature (tip) in first.
®
Compact Fusible Switches
Auxiliary Contact
N.O. + N.C. contact output to indicate the status of the switching mechanism on the Gladiator switch.
Mounts on the right side of the switch.
CFS-AUX
33 NO 34 NO
41 NC 42 NC
CFS-AUX
ting
at
Disconnect Switches
Star .50
$48 g at UL 98 Non-Fusible
Compact UL 98 t a rtin 0
S 4.0 Heavy Duty Switches
Non-Fusible Switches $12
100 - 600 Amp Range
30 - 100 Amp Range
• Fully visible
• Touch safe disconnection
• DIN-rail or back-plate mounted • High thermal and
• Direct or external operation handle dynamic withstand
• Double breaking per pole • High electrical and
mechanical endurance
R
at UL 508 Enclosed
t a r ting Sta
rtin
S .50 Non-Fusible Switches $66 g at
$18 30 - 60 Amp Range .00
• 1 removable
ground terminal
UL 508 Non-Fusible
Switches • Ability to add 1 power pole
and 1 auxiliary contact
16 - 80 Amp Range
• NEMA/UL type 1, 3R, 12,
• Compact and modular 4, 4X
• Direct or external operation • Suitable as motor disconnect
• DIN-rail or base mount
• Suitable as motor disconnect R
r t
Sta 7.25 Disconnect Switches
$8 30 Amp Rating
t
i n ga • Front operation
r t 0
Sta 214.5 • Touch safe covers
$ • Voltage sensing terminals
• Up to 200kA SCCR
R
at
ting
Star .75
R
$80 UL 98 Fusible
Disconnect Switches
30 - 600 Amp Range
UL 98 Manual • Front and side operation
Multipolar Load Switches • Touch safe covers
100 - 250 Amp Range • Up to 200kA SCCR
• Ideal for photovoltaic applications R
• Double break contact
• 600VDC per UL 98 / CSA
• 1000VDC per UL98B
To obtain the most current agency approval information, see the Agency Approval Checklist
• Up to 1000VDC per UL IEC 60947-3 characteristics section on the specific part number's web page at www.AutomationDirect.com
Disconnect Switches
Introduction
Non-Fusible
Disconnect Switches
Machine Control Power Distribution
Selection Guide UL 508 Non-Fusible
UL 98 Compact Non-Fusible UL 508 Non-Fusible UL 98 Non-Fusible UL 98B DC Non-Fusible
Enclosed Disconnect
• Which application? Disconnect Switches Disconnect Switches
Switches
Disconnect Switches Disconnect Switches
• Which function?
• Which operation handle?
• Which type of breaking?
Applications
Main switchboard
Distribution panel
Emergency disconnect
Local safety disconnect (padlockable)
Photovoltaic disconnect
Enclosed switches
Functions
3/4 pole non-fusible disconnect switch
Characteristics
Operation Manual (rotating)
Direct operation handle Front
External operation Front
handle Right side
Positive break
Indication of breaking
indication
Switch body Modular
Non-Fusible
Disconnect Switches
Assembly of Accessories
6 5
1
1. Switch body
7 2. Direct handle
3. External handle
4. Shaft and mount
5. Terminal shroud
6. Terminal shroud
2 7. Auxiliary contact
8 8. Additional pole
4
3
1
1. Switch body
2 2. Direct handle
3. External handle
7 4. Shaft
4 5. Terminal screen
6. Terminal screen
7. Auxiliary contacts
3
6
SIRCO M UL 98
Compact Non-Fusible
Disconnect Switches
To assemble a switch, please select:
Direct Operation External Operation
+ OR + +
Switch Body Direct Handle Switch Body Shaft External Handle
SIRCO M UL 98
Compact Non-Fusible
Disconnect Switches
Shaft Guide for External Handle
Part Number Description Handle Type Price
14190000 This accessory makes alignment connections between the shaft and handle easier. S00, S0 $1.50
Allows up to 15mm misalignment tolerance. Required for a shaft length over
300mm. Included with longer shafts.
14290000 S01, S1, S2, S3 $4.75
14190000
Additional Poles
Switch Body No.
Part Number Description Use Price
Rating (A) of Poles
Fourth pole module
22011003 switched 600VAC 100kA 30 1 $14.25
SCCR Adding one
additional pole
Fourth pole module transforms a
22011006 switched 600VAC 65kA 60 1 non-fusible $15.75 22011003
SCCR disconnect switch
from 3 poles to 4
Fourth pole module poles
22001010-UL switched 600VAC 100kA 100 1 $20.50
N or PE
N or PE
SCCR
Transforms the
Solid neutral pole module
22005011 unswitched 600VAC 30 - 100 1 3-pole switch into a $16.50
3-pole + solid neutral
Adds 1 ground
N or PE
N or PE
N or PE
N or PE
Grounding pole module
22009011 unswitched 600VAC 30 - 100 1 module pole to the $16.50
switch-disconnector
4th Pole Configurations
4th Pole Configurations
Terminal Shrouds
Switch Body
Part Number Description No. of Poles Price
Rating (A)
22941011 Terminal shroud line/load mount, 2 per pack, offers 30 - 100 1 $3.50
additional protection against direct contact with the terminals.
22943016 30 - 100 3 $5.75
22941011
Auxiliary Contacts
Switch Body
Part Number Description Contacts Price
Rating (A)
22990001-UL
SIRCO M UL 98
Compact Non-Fusible
Disconnect Switches
Technical Characteristics
Characteristics According to UL 98 / CSA 22.2#4
22013003 22013006 22003010-UL
General use rating (A) 30 60 100
Short-circuit rating at 480VAC (kA) 100 100 100
Short-circuit rating at 600VAC (kA) 100 100 25
Type of fuse J J J
Max fuse rating (A) 30 60 100
Max. motor hp / FLA 3-phase motor max.
220-240 VAC 10 / 28 20 / 54 20 / 54
440-480 VAC 20 / 27 40 / 52 50 / 65
600VAC 25 / 27 50 / 52 50 / 52
Max. motor hp / FLA 1-phase motor max.
120VAC 2 / 24 3 / 34 5 / 56
240VAC 5 / 28 10 / 50 10 / 50
Wire type/temperature Cu / 75°C (167°F)
Product weight – lb(kg) 1.3 (0.6)
Wire range
Solid (AWG) #12-10 #12-10 #12-10
Torque – lb·in (N·m) 35.4 (4) 35.4 (4) 35.4 (4)
Stranded (AWG) #10-1 #10-1 #10-1
Torque – lb·in (N·m) 35.4 (4) 35.4 (4) 35.4 (4)
Stranded (AWG) 1/0 1/0 1/0
Torque – lb·in (N·m) 39.8 (4.5) 39.8 (4.5) 39.8 (4.5)
Stranded (AWG) 2/0 2/0 2/0
Torque – lb·in (N·m) 44.3 (5) 44.3 (5) 44.3 (5)
Mechanical characteristics
Endurance (number of operating cycles) 10,000 10,000 10,000
Operating torque (lb·in / N·m) 12.4 / 1.4 12.4 / 1.4 12.4 / 1.4
Environmental - switch body
Operating temperature¹ -20°C to 70°C (-4°F to +158°F)
Flammability rating UL 94-V0
Mounting 35mm DIN rail or panel mount
Auxiliary contacts
Electrical characteristics A300 A300 A300
Agency approvals
UL file # E201138 (UL 98), CSA file # 112964 (C22.2 NO. 14)
¹ Temperature above 40°C, the current rating of the switch has to be de-rated 1% per °C over 40°C. Example, at 60°C a 100A switch is rated 80A.
Note: Short-circuit rating achieved when used with corresponding fuse type and max fuse rating.
To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page.
SIRCO M UL 98
Compact Non-Fusible
Disconnect Switches
Technical Characteristics (Continued)
Characteristics According to IEC 60647-3
22013003 22013006 22003010-UL
Thermal current Ith at 40°C (A) 30 60 100
Rated insulation voltage Ui (V) 800 800 800
Rated impulse withstand voltage Uimp (kV) 8 8 8
Rated operational currents Ie
400VAC / AC-22A utilization category (A)1 32 63 100
400VAC / AC-23A utilization category (A)1 32 63 100
690VAC / AC-22A utilization category (A)1 32 63 80
690VAC / AC-23A utilization category (A)1 32 63 63
Operational power in AC-23 (kW)2/3
@ 400VAC without prebreak AC in AC-23 15 30 45
@ 500VAC without prebreak AC in AC-23 15 30 45
@ 690VAC without prebreak AC in AC-23 18.5 30 45
Overload capacity (Ue 415VAC)
Rated short-circuit making capacity Icm (kA peak)4 12 12 12
Connection
Min. connection section (mm²) 2.5 2.5 10
Max. connection section (mm²) 70 70 70
1
Category with index A = frequent operation.
2
A/B: Category with index A = frequent operation - Category with index B = infrequent operation.
3
The power value is given for information only, the current values vary from one manufacturer to another.
4
For a rated operating voltage Ue = 400VAC
SIRCO M UL 98
Compact Non-Fusible
Disconnect Switches
Dimensions [inches/mm]
Dimensions
Switch Body Rating (A) / Overall Dimensions Terminal Switch Body Switch Mounting Connection
Units
Frame Size D min D Max E min E max Shrouds AC F F1 G J M N T
in 1.18 7.87 3.94 14.65 7.44 3.07 1.02 4.91 0.51 1.02 5.17 1.02
100 / M3
mm 30 201 100 372 189 78 26 124.6 13 26 131.4 26
SIRCO UL 98 Non-Fusible
Disconnect Switches
To assemble a switch, please select:
Direct Operation External Operation
+ OR + +
Switch Body Direct Handle Switch Body Shaft External Handle
14011520
SIRCO UL 98 Non-Fusible
Disconnect Switches
Auxiliary Contacts
Part Switch Body
Description Type Contacts Price
Number Rating (A)
Auxiliary Contact Block: 1 Form C,
27990021 10A @ 125 VAC 1 NO / 1 NC $9.25
C Type
Auxiliary Contact Block: 1 Form C, standard level
27990022 10A @ 125 VAC, 2/pk 1 NO / 1 NC $12.75
100-600
Auxiliary Contact Block: 1 Form C, 1A
27990121 @ 125 VAC, low impedance 1 NO / 1 NC $11.25
C Type
Auxiliary Contact Block: 1 Form C, 1A low impedance
27990122 @ 125 VAC, low impedance, 2/pk 1 NO / 1 NC $17.00
27990021
Terminal Screens
Switch Body
Part Number Description No. of Poles Position Price
Rating (A)
27983021 Line $14.75
3
27988021 100-250 Load $14.75
27984021 Terminal screens provide line or load 4 Line or load $17.00
protection against direct contact with
27983041 terminals or connection parts. Line $22.25
400
27988041 3 Load $22.25 27983021
27983060* 600 Load $50.25
* Load side screen, the line side is included with the switch.
Terminal Lugs
Part Switch Body Wire Lugs No cables
Description Price
Number Rating (A) Range per kit per lug
39542020 2 $12.25
SIRCO UL 98 Non-Fusible
Disconnect Switches
Technical Characteristics
Characteristics According to UL 98 / CSA 22.2#4
27003011 27003021 27003041 27003060
27004011 27004021
General use rating (A) 100 200 400 600
Short-circuit rating at 600VAC (kA) 200 200 200 200
Type of fuse J J J J
Max fuse rating (A) 100 200 400 600
Max. motor hp / FLA 3-phase motor max.
220-240 VAC 30 / 80 75 / 192 125 / 312 200 / 480
440-480 VAC 75 / 96 150 / 180 250 / 302 400 / 477
600VAC 100 / 99 200 / 192 350 / 336 350 / 336
Max. motor hp / FLA 1-phase motor max.
240VAC 10 / 50 10 / 50 – –
Max. motor hp / DC FLA motor max.
120VDC¹ 10 / 76 15 / 112 20 / 148 20 / 148
250VDC² 15 / 55 15 / 55 50 / 173 50 / 173
Wire type/temperature Cu / 75°C (167°F)
Product weight – lb (kg)
3-pole 4.2 (1.91) 4.2 (1.91) 10.0 (4.6) 18.1 (8.2)
4-pole 5.0 (2.3) 5.0 (2.3) 12.3 (5.6) 23.9 (10.9)
Wire range
Stranded (AWG) #6-300MCM #6-300MCM #4-600MM (2) #2-600MCM
Torque – lb·in (N·m) 275 (31) 275 (31) 550 (62) 375 (42.4)
Stranded (AWG) – – (2) 1/0-250MCM –
Torque – lb·in (N·m) – – 550 (62) –
Stranded (AWG) – – (2) #6-2 –
Torque – lb·in (N·m) – – 200 (22.6) –
Stranded (AWG) – – (2) #1-350MCM –
Torque – lb·in (N·m) – – 375 (42.4) –
Environmental – switch body
Operating temperature³ -20°C to 70°C (-4°F to +158°F)
Flammability rating UL 94-V0
Mechanical characteristics
Endurance (number of operating cycles) 10,000 8,000 6,000 6,000
Operating torque (lb·in / N·m) 88.5 / 10 88.5 / 10 128.3 / 14.5 327.5 / 37
Mounting Panel mount
Auxiliary contacts
Electrical characteristics A300 A300 A300 A600
Approvals
UL file # E201138 (UL 98), CSA file # 112964 (C22.2 NO. 4)
1
2 pole in series
² 3 pole in series
³ Temperatures above 40°C, the current rating of the switch has to be de-rated 1% per °C over 40°C. Example, at 60°C a 100A switch is rated 80A
Note: Short-circuit rating achieved when used with corresponding fuse type and max fuse rating.
To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page.
SIRCO UL 98 Non-Fusible
Disconnect Switches
Technical Characteristics
Characteristics According to IEC 60647-3
27003011 27003021 27003041 27003060
27004011 27004021
Thermal current Ith at 40°C (A) 100 200 400 600
Rated insulation voltage Ui (V) 1000 1000 1000 1000
Rated impulse withstand voltage Uimp (kV) 12 12 12 12
Rated operational currents Ie
400VAC / AC-22A utilization category (A)1 100 200 400 630
400VAC / AC-23A utilization category (A)1 100 200 400 630
690VAC / AC-22A utilization category (A)1 100 200 400 500
Connection
Min. Cu cable cross section (mm²) 35 70 185 2 x 150
Min. Cu busbar (mm²) – – – 2 x 30 x 5
690VAC / AC-23A utilization category (A)1 100 200 315 200
Operational power in AC-23 (kW)2/3
@ 400VAC without prebreak AC in AC-23 51 100 220 355
@ 500VAC without prebreak AC in AC-23 63 140 280 450
@ 690VAC without prebreak AC in AC-23 90 185 185 185
Overload capacity (Ue 415VAC)
Rated short-circuit making capacity Icm (kA peak)4 17.6 32 48 48
1
Category with index A = frequent operation.
2
A/B: Category with index A = frequent operation - Category with index B = infrequent operation.
3
The power value is given for information only, the current values vary from one manufacturer to another.
4
For a rated operating voltage Ue = 400VAC
SIRCO UL 98 Non-Fusible
Disconnect Switches
Dimensions [inches/mm]
Dimensions
Switch Overall Dims Terminal Shrouds Switch Body Switch Mounting Connection
Body Unit
Rating (A) C AC AD F 3p F 4p H J1 3p J1 4p K M 3p M 4p N R1 R2 T U V W Y Z AA CA
in 3.72 10.1 3.05 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.27 5.31 0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3 0.6
100
mm 94.6 256 77.5 180 230 107 55 105 45.6 160 210 135 9 7 50 25 30 11 3.5 34.4 160 15
in 3.72 10.1 3.05 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.27 5.31 0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3 0.6
200
mm 94.6 256 77.5 180 230 107 55 105 45.6 160 210 135 9 7 50 25 30 11 3.5 34.4 160 15
in 4.92 16 4.15 9.05 – 6.53 2.95 – 2.65 8.26 – 7.67 0.35 0.27 2.56 1.77 1.97 0.43 0.2 2.08 10.2 0.8
400
mm 128 406 115 230 – 166 75 – 67.5 210 – 195 9 7 65 45 50 13 5 53 260 20
27003060
Dimensions
Switch Terminal Shrouds Switch Body Switch Mounting Connection
Body Unit
Rating (A) AC F 3p F 4p H J1 3p J1 4p M 3p M 4p N N1 AA Z
in 18.12 11 – 5.5 5 – 10.03 – 6.88 2.34 12.6 1.85
600
mm 460 280 – 140 127.5 – 255 – 175 59.5 320 47
Please see our website www.AutomationDirect.com for complete engineering drawings.
+ OR + +
Switch Body Direct Handle Switch Body Shaft External Handle
22003001-UL 20 3 $19.75
22003002-UL 25 3 $21.00
Non-fusible UL 508 disconnect rotary 600VAC
22003003-UL disconnect switch 32 3 $21.50
22003004-UL 40 3 $22.25
22003006-UL 63 3 $30.25
22003008-UL 80 3 $34.25
14070515
Shafts for External Handles
Part Switch Body Handle Length
Description Price
Number Rating (A) Type in mm
14070515 5.9 150 $3.00
For 3/4-pole switches: shafts are for
14070520 external front and side handle S00, S0 7.9 200 $4.00
14070532 12.6 320 $5.25
16 - 100
14040520 7.9 200 $7.25
For 3/4-pole switches: shafts are for
14040532 external front and side handle. S01 12.6 320 $8.75
14040540 15.7 400 $15.25
Additional Poles
Switch Body No.
Part Number Description Use Price
Rating (A) of Poles
22001000-UL
22001000-UL 16 $10.00
22001001-UL 20 $11.50
Transforms a 3-pole
22001002-UL Module switched 4th pole 25 1 switch into a 4-pole $11.50
22001003-UL 32 $12.00
22001004-UL 40 $13.00
4th Pole Configurations
4th Pole Configurations
Terminal Shrouds
Switch Body
Part Number Description No. of Poles Price
Rating (A)
22941005 1 $2.00
16-40
22943005 Terminal shroud line/load mount, 2 per pack, offers 3 $3.00
additional protection against direct contact with the terminals.
22941009 1 $2.50 22941005
63-80
22943009 3 $4.00
Auxiliary Contacts
Switch Body
Part Number Description Contacts Price
Rating (A)
22990001-UL Auxiliary contact block module, 10A @ 240VAC, can be 16 - 100 1 NO / 1 NC $13.75
mounted on left or right side of switch, maximum 4 auxiliary
22990011-UL contacts can be used (requires 2 modules) 16 - 100 2 NO $14.75
22990001-UL
¹ Temperatures above 40°C, the current rating of the switch has to be de-rated 1% per °C over 40°C. Example, at 60°C a 100A switch is rated 80A
Note: Short-circuit rating achieved when used with corresponding fuse type and max fuse rating.
To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page.
Dimensions
Switch Body Overall Dimensions Terminal Switch Body Switch Mounting Connection
Units
Rating (A) D min D Max E min E max Shrouds AC F F1 G J M N T
in 1.18 9.25 3.94 14.64 4.33 1.77 0.59 2.67 0.59 1.18 2.95 0.59
16 - 40
mm 30 235 100 372 110 45 15 68 15 30 75 15
in 1.18 9.25 3.94 14.64 4.33 2.06 0.69 2.99 0.69 1.38 3.35 0.69
63 - 80
mm 30 235 100 372 110 52.5 17.5 76 17.5 35 85 17.5
General characteristics
• Gray enclosure with red handle • Operating temperature -20° to +70°C [-4° to +158°F]
• Equipped with a 3 pole SIRCO M • Polycarbonate plastic
• 1 removable ground terminal • Flammability UL94-5VA
• Possibility of adding 1 power pole and 1 auxiliary contact • Nema/UL type 1, 3R, 12, 4, 4X
Dimensions [inches/mm]
Size 2
Size 1
¹ Temperatures above 40°C, the current rating of the switch has to be de-rated 1% per °C over 40°C. Example, at 60°C a 100A switch is rated 80A
Note: Short-circuit rating achieved when used with corresponding fuse type and max fuse rating.
To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page.
SIRCO UL 98B DC
Non-Fusible
Disconnect Switches
To assemble a switch, please select:
Direct Operation External Operation
+ OR + +
Switch Body Direct Handle Switch Body Shaft External Handle
SIRCO UL 98B DC
Non-Fusible
Disconnect Switches
Shaft Guide for External Handle
Fits
Part Number Description Price
Handle Type
This accessory makes alignment connections between the shaft and handle
14290000 easier. Allows up to 15mm misalignment tolerance. Required for a shaft S01, S1, S2, S3 $4.75
length over 300mm. Included with longer shafts.
14290000
Auxiliary Contacts
Part Switch Body
Description Type Contacts Price
Number Rating (A)
Auxiliary contact block: 1 Form C, 10A
27990021 @ 125VAC 1 NO / 1 NC $9.25
C Type
Auxiliary contact block: 1 Form C, 10A standard level
27990022 @ 125VAC, 2/pk 1 NO / 1 NC $12.75
100-600
Auxiliary contact block: 1 Form C, 1A
27990121 @ 125VAC, low impedance 1 NO / 1 NC $11.25
C Type
Auxiliary contact block: 1 Form C, 1A low impedance
27990122 @ 125VAC, low impedance, 2/PK 1 NO / 1 NC $17.00 27990021
Terminal Screens
Switch Body
Part Number Description No. of Poles Position Price
Rating (A)
27983021 Line $14.75
Terminal screens provide line or load 3
27988021 protection against direct contact with 100-250 Load $14.75
terminals or connection parts.
27984021 4 Line or load $17.00 27983021
Terminal Lugs
Part Switch Body Wire Lugs No cables
Description Price
Number Rating (A) Range per kit per lug
Terminal lug kits allow for the
39542020 connection of bare copper cables on to
the terminals (no spade lugs). 100-250 #6 - 300MCM 2 1 $12.25
Cable type Cu/Al.
39542020
SIRCO UL 98B DC
Non-Fusible
Disconnect Switches
Technical Characteristics
Characteristics According to UL 98 / CSA 22.2#4 and UL 98B
27DC3011, 27DC4011 27DC3021, 27DC4021
General use rating (A) 100 250
600VDC / 3P in series (A) 100 250
1000VDC / 4P in series (A) 100 250
Short-circuit capacity at 600VDC
Prospective short-circuit current (kA rms)¹ 20 20
Type of fuse Mersen A70P100 Mersen A70P100
Associated fuse rating (A) 200 200
Short-circuit capacity at 1000VDC (any breaker)
Prospective short-circuit current (kA rms)¹ 10 10
Wire type/temperature Cu/Al / 75°C (167°F)
Product weight – lb (kg)
3-pole 4.2 (1.91)
4-pole 5.0 (2.3)
Wire range
Stranded (AWG) #6-300MCM #6-300MCM
Torque - lb·in (N·m) 275 (31) 275 (31)
Environmental – switch body
Operating temperature¹ -20°C to 70°C (-4°F to +158°F)
Flammability rating UL 94-V0
Mechanical characteristics
Endurance (number of operating cycles) 10,000 10,000
Operating torque (lb·in / N·m) 88.5 / 10 88.5 / 10
Mounting Panel mount
Auxiliary contact
Electrical characteristics A300 A300
Agency approvals
UL file # E201138 (UL 98), E346418 (UL 98B) CSA file # 112964 (22.2 No. 4)
¹ Temperatures above 40°C, the current rating of the switch has to be de-rated 1% per °C over 40°C. Example, at 60°C a 100A switch is rated 80A
Note: Short-circuit rating achieved when used with corresponding fuse type and max fuse rating.
To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page.
SIRCO UL 98B DC
Non-Fusible
Disconnect Switches
Dimensions [inches/mm]
Dimensions
Switch Body Overall Dims Terminal Shrouds Switch Body Switch Mounting Connection
Unit
Rating (A) C AC AD F 3p F 4p H J1 3p J1 4p K M 3p M 4p N R1 R2 T U V W Y Z AA CA
in 3.72 10.1 3.05 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.27 5.31 0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3 0.6
100-250
mm 94.6 256 77.5 180 230 107 55 105 45.6 160 210 135 9 7 50 25 30 11 3.5 34.4 160 15
Mounting Orientation
FUSERBLOC UL 489
Compact Fusible
Disconnect Switches
To assemble a switch, please select:
Direct Operation External Operation
+ OR + +
Switch Body Direct Handle Switch Body Shaft External Handle
Handles
Part Switch Body Handle Handle NEMA/
Description Test Price
Number Rating (A) Color Type UL Type
37294012 Direct handle for class CC disconnect switches* 30 Black – – – $15.00
37294014 Direct handle for class J disconnect switches* 30 Black – – – $15.00
14930111 30 Black/Blue S0 I-O $16.75
1, 3R, 12
14940111 30 Red/Yellow S0 I-O $16.75 Direct Handle
149D0111 30 Black/Blue S0 I-O $19.25 37294012
4, 4X
149E0111 30 Red/Yellow S0 I-O $19.25
141F2111 Front operation handle for compact UL 489 30 Black/Blue S1 I-O $21.25
fusible disconnect switches, defeatable and 1, 3R, 12
141G2111 lockable 30 Red/Yellow S1 I-O $21.25
141D2111 30 Black/Blue S1 I-O $28.00
S0 Handle
141E2111 30 Red/Yellow S1 I-O $28.00 149D0111
4, 4X
141D2115 30 Black/Blue S1 I - O - Test $29.50
141E2115 30 Red/Yellow S1 I - O - Test $29.50
141D2911 External heavy duty front handles, 30 Black/Blue S1 I-O $32.25
4, 4X
141E2911 shaft required** 30 Red/Yellow S1 I-O $32.25
* Defeatable S1 Handle
**Heavy duty handles have larger metal hasp to accommodate multiple locking devices. 141F2111
Shafts for External Handles
Part Switch Body Handle Length
Price 14050620
Number Rating (A) Type in mm
14050620 7.9 200 $7.25
14050632 S0 12.6 320 $8.75
14050640 15.7 400 $9.50
30
14010520 7.9 200 $6.75
14010532 S1 12.6 320 $8.00 14010520
14010540 15.7 400 $9.00
FUSERBLOC UL 489
Compact Fusible
Disconnect Switches
Shaft Guide for External Handle
Fits
Part Number Description Price
Handle Type
14290000 This accessory makes alignment connections between the shaft and handle S01, S1, S2, S3 $4.75
easier. Allows up to 15mm misalignment tolerance. Required for a shaft
14190000 length longer than 300mm. Included with longer shafts. S00, S0 $1.50 14290000
Auxiliary Contacts
Part Switch Body Contacts
Description Price
Number Rating (A)
Front mount auxiliary contacts can be configured to be operated
39990701 on standard and TEST position switches. Each slot can accomo- 1 NO $6.25
date up to 2 interlocked auxiliary contacts. 3A @ 240VAC. 30 - 600
39990702 1 NC $6.25 39990701
For 30 to 200A/J, maximum of 4 auxiliary contacts
Technical Characteristics
Characteristics According to UL 489 / CSA 22.2#5
37103003, 37104003 37103004, 37104004
37105003 37105004
General use rating (A) 30 30
Short circuit rating at 600VAC (kA) 100 100
Type of fuse CC J
Maximum fuse rating (A) 30 30
Operational power (hp) / current max operation 3-phase (A)
220-240 VAC 7.5 / 22 7.5 / 22
440-480 VAC 15 / 21 15 / 21
600VAC 20 / 22 20 / 22
125VDC¹ 3 / 25 3 / 25
250VDC² 5 / 20 5 / 20
Product weight – lb (kg) 1.3 (0.6) 1.4 (0.6)
Environmental – switch body
Operating temperature³ -20°C to 70°C (-4°F to +158°F)
Flammability rating UL 94-V0
Mechanical endurance
Endurance (number of operating cycles) 10,000 10,000
Operating torque (lb·in / N·m) 3.5 3.5
Mounting 35mm DIN rail or panel mount
Connection
Min. connection cross-section (AWG)² #14 #14
Max. connection cross-section (AWG)² #10 #10
Torque - lb·in (N·m) 27 (3) 27 (3)
Agency Approvals
UL file # E255272 (UL 489, C22.2 No.5)
¹ 2 poles in series
² 3 poles in series
³ Temperatures above 40°C, the current rating of the switch has to be de-rated 1% per °C over 40°C. Example, at 60°C a 100A switch is rated 80A
Note: Short-circuit rating achieved when used with corresponding fuse type and max fuse rating.
To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page.
FUSERBLOC UL 489
Compact Fusible
Disconnect Switches
Dimensions [inches/mm]
Class CC
Class J
Dimensions
Switch Body Switch Body Switch Mounting Connection
Unit
Rating (A) F H H1 J J1 N N1 AA Z
30 in 3.78 3.28 5.19 1.47 0.59 3.13 1 4.56 1.12
Class CC mm 96 83.5 132 37.5 15 79.5 25.5 116 28.5
30 in 4.13 3.89 – 1.47 0.59 3.30 1 4.56 1.12
Class J mm 105 99 – 37.5 15 84 25.5 116 28.5
FUSERBLOC UL 98 Fusible
Disconnect Switches
To assemble a switch, please select:
Direct Operation External Operation
+ OR + +
Switch Body Direct Handle Switch Body Shaft External Handle
FUSERBLOC UL 98 Fusible
Disconnect Switches
Right Side Operation Handles (No door interlocking)
Part Switch Body Fits Handle Handle NEMA/ Test
Description Price
Number Rating (A) Frame Color Type UL Type
141H6111 Black/Blue $28.25
30-60 4 S1
141I6111 Side operation handle for UL 98 Red/Yellow $28.25
142H6111 fusible disconnect switches Black/Blue $40.50
100-400 5, 6, 7 S2
142I6111 Red/Yellow $40.50
4, 4X I-O
141H6911 Black/Blue $56.50
Heavy duty side operation handle 30-60 4 S1
141I6911 Red/Yellow $56.50
for UL 98 fusible disconnect
142H6911 switches* Black/Blue $68.75
100-400 5, 6, 7 S2
142I6911 Red/Yellow $68.75 141H6111
* Heavy duty handles have larger metal hasp to accommodate multiple locking devices.
14290000
Auxiliary Contacts
Body Switch
Part Number Description Contacts Price
Rating (A)
Front mount auxiliary contacts can be configured to
39990701 be operated on standard and TEST position switches. 1 NO $6.25
Each slot can accomodate up to 2 interlocked auxil- 30 - 600
iary contacts. 3A @ 240VAC.
39990702 1 NC $6.25
For 30 to 200A/J, maximum of 4 auxiliary contacts
39990701
3999U041 Side operated auxiliary contacts for frame sizes 3 to 8 30-600 1 NO $19.50
UL 98 fusible disconnect switches, position OFF and
ON signalled by 1 to 4 NO + NC auxiliary contacts.
3999U042 10A @ 600 VAC/DC. 2/pk 30-600 1NO / 1NC $38.00
3999U041
FUSERBLOC UL 98 Fusible
Disconnect Switches
Terminal Shrouds
Switch Body
Part Number Description Pcs/pk Price
Rating (A)
38982020 200 2 $12.50
Terminal Lugs
Switch Body
Part Number Wire Range Wires per lug Lugs per Kit Price
Rating (A)
39542020 2 $12.25
39544020 4 $24.75
Cables
Part Number Cable Length (feet) Cable Length (m) Price
37299992 37299903
37299992 3 1 $112.00
FUSERBLOC UL 98 Fusible
Disconnect Switches
Blown Fuse Monitors
These fuse monitors detect fuse opening using a bistable
(latching) relay and a signaling LED. They can be mounted
on a 35mm DIN rail, a back plate, next to the disconnect
switch or on the door, or can be mounted directly on the
side of Fuserbloc (3861xxx) series switches.
38199120 38299120
Dimensions [inches/mm]
FUSERBLOC UL 98 Fusible
Disconnect Switches
Technical Characteristics
Characteristics According to UL 98 / CSA 22.2 #4
38612004 38612005 38612010 38612020
38613004 38613005 38613010 38613020 38513038 38503060
38616004 38616005 38616010 38616020
General use rating (A) 30 60 100 200 400 600
Short circuit rating at 600VAC (kA) 200 100 200 200 200 200
Type of fuse J J J J J J
Max. fuse rating (A) 30 60 100 200 400 600
Operational power (hp) / current max operation 3-phase (A)
220-240 VAC 7.5 / 22 15 / 42 30 / 80 60 / 154 125 / 312 200 / 480
440-480 VAC 15 / 21 30 / 40 60 / 77 125 / 156 250 / 302 500 / 590
600VAC 20 / 22 50 / 52 75 / 77 150 / 144 350 / 336 500 / 475
125VDC¹ 3 / 25 5 / 40 7.5 / 58 15 / 112 20 / 148 –
250VDC² 5 / 20 10 / 38 20 / 72 40 / 140 50 / 173 –
Mechanical endurance
Endurance (number of operating cycles) 10,000 10,000 10,000 8,000 6,000 5,000
Operating torque (lb·in / N·m) 4.1 8.7 9.7 10.2 17 66.2
Wire type/temperature Cu / 75°C (167°F) Cu/Al / 75°C (167°F)
Product weight – lb (kg)
2-pole 3.0 (1.3) 3.1 (1.4) 4.07 (1.8) 5.7 (2.6) – –
3-pole 3.8 (1.7) 4.1 (1.8) 5.3 (2.4) 7.8 (3.5) 16.6 (7.6) 44.2 (20.1)
4-pole 4.7 (2.1) 4.8 (2.2) 6.49 (2.9) 10.8 (4.9) – –
Wire range
Solid (AWG) #14-10 #14-10 #12-10 – – –
Torque – lb·in (N·m) 27 (3.1) 31 (3.5) 35.4 (4) – – –
Stranded (AWG) #14-6 #14-6 #12-1 #6-300MCM #4-600MCM (2) #2-600MCM
Torque – lb·in (N·m) 31 (3.5) 31 (3.5) 35.4 (4) 275 (31) 550 (62) 375 (42.4)
Stranded (AWG) – – – – (2) 1/0-250MCM –
Torque – lb·in (N·m) – – – – 550 (62) –
Environmental – switch body
Operating temperature³ -20°C to 70°C (-4°F to +158°F)
Flammability rating UL 94-V0
Mounting 35mm DIN rail or panel mount panel mount
Agency Approvals
UL file # E201138 (UL 98), CSA file # 112964 (C22.2 No. 4)
¹ 2 poles in series
² 3 poles in series
³ Temperatures above 40°C, the current rating of the switch has to be de-rated 1% per °C over 40°C. Example, at 60°C a 100A switch is rated 80A
To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page.
FUSERBLOC UL 98 Fusible
Disconnect Switches
Dimensions [inches/mm]
30A to 60A - Frame Size 4
Note: For 2-pole and 4-pole devices decrease overall width by 1.41"/36mm
FUSERBLOC UL 98 Fusible
Disconnect Switches
Dimensions [inches/mm]
200A - Frame Size 6
Note: For 2-pole and 4-pole devices decrease overall width by 1.96"/50mm
FUSERBLOC UL 98 Fusible
Disconnect Switches
Dimensions [inches/mm]
600A - Frame Size 8
Accessories Dimensions
Handles
[inches/mm]
S0 Type
Handle Dimensions Direction of Operation Door Drilling
S01 Type
Handle Dimensions Direction of Operation Door Drilling
Accessories Dimensions
Handles
[inches/mm]
S3 Type
Handle Dimensions Direction of Operation Door Drilling
Accessories Dimensions
Handles
[inches/mm]
S0 Type
Handle Dimensions Direction of Operation Door Drilling
S01 Type
Handle Dimensions Direction of Operation Door Drilling
Accessories Dimensions
Handles
[inches/mm]
Accessories Dimensions
Handles
[inches/mm]
S1 Type
Handle Dimensions Direction of Operation Door Drilling
Note: Test position included on certain models only as indicated in the selection tables.
Please see our website www.AutomationDirect.com for complete engineering drawings.
Accessories Dimensions
Handles
[inches/mm]
S2 Type
Handle Dimensions Direction of Operation Door Drilling
S3 Type
Handle Dimensions Direction of Operation Door Drilling
Note: Test position included on certain models only as indicated in the selection tables.
Accessories Dimensions
Shafts for Non-Fusible Disconnect Switches
[inches/mm]
Accessories Dimensions
Shafts for Fusible Disconnect Switches
[inches/mm]
Accessories Dimensions
Lugs
[inches/mm]
39543041 39543060
Accessories Dimensions
Auxiliary Contacts and Additional Poles
[inches/mm]
3999U041
3999U042
27990021
27990022
27990121
22990001-UL
22990011-UL
39990701
39990702
22011003
22011006
22001010-UL
22005011
22009011
22001000-UL
22001001-UL
22001002-UL
22001003-UL
22001004-UL
6
7
3
2
1 8
10 9
5
12 11
1. SD1
1 . Sdirect
D1 dihandle
rect haload
ndle switch
switch disconnect on5the
. FSD
ixeseries
d neudisconnect
tral pole switch
for SD1 9. Fixed
9.neutral
Fixed pole
neufor
traSD2
l pole for SD2
2. SD2
2. Sdirect
D2 dihandle
rect haload
ndle switch
switch disconnect 7. 4th6.pole
SDfor
1-SSD2
D2 auxiliary contact 1NO+1NC 10. Operating
10. Opshaft
erating shaft
3. 4th
3. 4pole
th Pfor
oleSD1
for SD1 8. Grounding
7. 4th Ppole
ole for
forSD2
SD2 11. Non-defeatable
11. Door intdoor
erlocinterlock
k hendhandle
le
4. Grounding
4. Groundpoleingfor
poSD1
le for SD1 8. Grounding pole for SD2 12. Emergency
12. Emedoor
rgeninterlock
cy doohandle
r interlock handle
5. Fixed neutral pole for SD1
6. SD1-SD2 auxiliary contact 1NO + 1NC
One auxilliary contact block can be used
Our SD1 series non-fused load switches allow breaking of equipment loads
up to 600 VAC, at a nominal current of 32 amps. They are DIN-rail or panel-
mountable. A line of standard accessories is available for this model.
Note: One auxilliary contact block can be used on the SD series disconnect switch
SD2-AUX
2.05(52)
Dia 2.83(72)
2.95(75)
3.35(85)
2.56(65)
2.17(55)
1.77(45) 1.22(31)
1.61(41)
0.55(14) 1.77(45)
0.39(10)
2.20(56)
0.51(13)
2.48(63)
1.42(36)
3.15(80)
Dia 2.83(72)
2.80(71)
2.56(65)
2.40(61)
1.77(45)
1.22(31)
1.97(50)
)
.2
1.57(40)
(3
26
.1
.0
ia
D
Cutout
3.7(94)
Dia. 1.57(40)
1.77(45)
Dia 0.16(4)
Dia 0
.87(2
2)
0.27(6.8)
SD-CON dimensions
1.04(26.3)
1.2(30.5)
0.2(5)
3.3(82.8)
1.5(39)
2.1(52.3)
2.7(67.3) Dimensions in inches(millimeters)
Fuse Blocks
Fuses can be used for a variety of over- In addition, the current limiting line is And, we’ve not forgotten the accessories
current and overload applications. They recognized for NEC branch circuit pro- you need: fuse holders and fuse blocks
can be used to protect transformers, tection and Type 2 coordinated applica- are available in a variety of 1, 2, and
motors, DC power supplies, lighting cir- tions for IEC or NEMA starters/contac- 3-pole form factors.
cuits, contactors, relays and other indus- tors.
trial and commercial electrical equip- Small dimension fuses are perfect in size
ment and conductors. and ratings for protection in electronic
AutomationDirect now carries a vast as- applications.
Feeder In
sortment of fuse types. General purpose
Midget Class fuses are typically used
as supplemental protection for control RK5 RK1
loads. IWhere adherence to extensive
current limiting codes is not required,
the Class M Midget fuses are a great
low-cost solution for both time-delay
and fast-acting protection. Current
Class Class Class Class Class Class
Limiting RK1 RK1 RK5
J J J J CC J
Current limiting fuses, frequently used Class CC
in applications for motor branch circuit
protection, are available in both time-
delay and fast-acting models.
Resistance Inductive
Feeder for
Load Load
MOL Lighting
M Panel
9
power supplies need protection. Minimal maintenance
High interrupting rating uses do not require periodic recalibration as do
F
Long life
10
you are not paying a high premium for a high inter-
rupting capacity. Our current limiting fuses meet the
UL and NEC codes. s a fuse ages, the speed of response will not slow
A
down or change. A fuse’s ability to provide protec-
tion will not be adversely affected by the passing of
Reliability
4 uses have no moving parts to wear out or become
F
contaminated by dust or oil.
time.
(Sold in packages, prices shown are per piece) All fuses are 13/32” x 1-1/2”.
All prices are U.S. published prices. AutomationDirect prices as of 12/13/2017. Prices and specifications may vary by
dealer. Littlefuse prices are from http://www.newark.com 12/13/2017. Prices subject to change without notice.
Fuse Block
Fuse Fuse Holders
Fuse Amperage
Class Description Application
Series Range
All general purpose circuits with high inrush inductive loads includ-
Most popular current limiting dual element time delay fuses ing motor branch circuits and transformers. Also suited for lighting
JDL available. Small physical size and high preformance characteris- loads. Recommended for type 2 (no damage) protection of IEC style
tics makes the class J ideal for any space limited applications motors, starters, and contactors.
J 1A to 600A JHL Class J fuses combine the performance of high-speed
semiconductor fuses and the convenience of Class J branch- AC and DC drives, electronic motor controllers, power semiconductor
JHL circuit fuses in one small package. Ideal for AC and DC drives devices that utilize diodes, GTOs, SCRs, or SSRs.
and controllers.
ECNR 1A to 600A The dual element time delay characteristics of these fuses Use in AC power distribution system mains, feeders, and branch
typically allows them to be sized closer to the running ampacity circuits. Recommended for high inrush inductive loads, like motors
RK5
ECSR 3A to 600A of inductive loads to reduce cost and improve over current and transformers, and non inductive loads like lighting, and heating
protection. loads.
LENRK 10A to 600A These dual element time delay fuses have up to 40% more Use in AC power distribution system mains, feeders, and branch
RK1 current limitation and up to 350% more I2t limitation under fault circuits. Recommended for high inrush inductive loads, like motors
LESRK 5A to 600A conditions than the ECNR and ECSR fuses, reducing the potential and transformers, and non inductive loads like lighting, and heating
for damage. loads.
TJN These fuses are extremely fast-acting fuses in a compact, space- These fuses are ideal as the main fuse protection for panel boards,
T 1A to 600A
TJS saving size. load centers, meter stacks, and AC drives.
Fast acting characteristics with 200kA Interrupting Rating, and Recommended for branch circuit protection, resistive heating loads,
HCLR CC 0.5A to 30A compact design are an excellent choice for inductive loads as and lighting loads
well as resistive loads
Time delay characteristics with 200kA Interrupting Rating, and Recommended for Motor Branch protection, short circuit protection
HCTR CC 0.25A to 30A compact design are an excellent choice for high inductive loads. required by NEC® 430.52 and for Primary protection for control
Meets the requirements of the NEC® 430.72 and UL508 transformer loads.
Low peak design was developed specifically for motor protection,
Recommended for small horsepower motor circuits. Can provide Type
EDCC CC 0.5A to 30A Provides excellent current limiting capabilities up to 200KA
2 coordinated protection for IEC or NEMA starters/contactors
600VAC
Provides supplemental protection to end-use equipment with a Recommended for control circuits, street lighting, HID lighting, and
MCL Midget 0.5A to 50A 100KA interruption rating, 600VAC. Fast acting design responds electronic equipment protection
quickly to both overloads and short-circuit protection
Provides supplemental protection to end-use equipment with a Recommended to use as supplemental protection for non inductive
MOL Midget 0.5A to 30A 10,000A interruption rating, economical laminated paper tube control loads and lighting circuits
Provides supplemental protection to high inrush loads. has a Recommended to use as supplemental protection for inductive
MEQ Midget 0.25 to 30A 10,000A interruption rating, 500VAC. Fiber tube construction. control loads such as transformers and solenoids.
Provides supplemental protection to high inrush loads. has a Recommended to use as supplemental protection for inductive
MEN Midget 0.5A to 30A 10,000A interruption rating, fiber tube construction. Dual ele- control loads such as transformers and solenoids, and other high
ment allows harmless inductive surges to pass without opening. inrush electronics circuits.
1 1/4” x 1/4” Fast acting 1/4” x 1-1/4” ceramic tube construction.
ABC Ceramic 0.5A to 30A Small dimension electronic fuses. Recommended as supplemental protection for electronic applications
1 1/4” x 1/4” Fast acting 1/4” x 1-1/4” glass tube construction.
AGC Glass 0.5A to 30A Small dimension electronic fuses. Recommended as supplemental protection for electronic applications
5mm x 20mm 0.063A to 15A Fast acting 5mm x 20mm glass tube construction.
GMA Glass Small dimension electronics fuses. Recommended as supplemental protection for electronic applications
5mm x 20mm Medium Time Delay 5mm x 20mm glass tube construction.
GMC Glass 0.5A to 10A Small dimension electronics fuses. Recommended as supplemental protection for electronic applications
1 1/4” x 1/4” Time Delay 1/4” x 1-1/4” ceramic tube construction.
MDA Ceramic 0.5A to 20A Small dimension electronics fuses. Recommended as supplemental protection for electronic applications
1 1/4” x 1/4” 0.0625A to 20A Time Delay 1/4” x 1-1/4” glass tube construction.
MDL Glass Small dimension electronics fuses. Recommended as supplemental protection for electronic applications
5mm x 20mm 0.032A to 10A Fast acting 5mm x 20mm glass tube construction.
S500 Glass Small dimension electronics fuses. Recommended as supplemental protection for electronic applications
5mm x 20mm 0.25A to 6.3 A Time Delay 5mm x 20mm glass tube construction.
S506 Glass Small dimension electronics fuses. Recommended as supplemental protection for electronic applications
Suited for protection of low interrupting circuit breakers and non-
LCU L 601-1200 A Fast acting current limiting for non-inductive applications. inductive loads.
Selection Guide
Line Overview The fuse selection guide below is a general summary of the
specifications included for each fuse type. This selection guide
The Edison family of fuses, fuse blocks and fuse holders is di- does not include the many variables that can exist for specific
vided into two classes: situations such as local codes, unusual temperature, or other
1. Current Limiting: Class CC, Class J, Class L, Class RK, Class T operating conditions. When selecting fuses, be sure to com-
2. General Purpose: Class M Midget and Small Dimension ply with any applicable PUBLIC SAFETY standards that apply to
Overcurrent Protection Devices (OPD).
Edison Fuses Selection Guide and General Specifications
Current Limiting
Description
Class J Class RK5 Class RK1 Class T Class L Class CC
Fuse Type Fast-Acting Time-Delay Time-Delay Extremely Fast-Acting Fast-Acting Fast-Acting Time-Delay
Part Number JHL JDL ECNR ECSR LENRK LESRK TJN TJS LCU HCLR HCTR EDCC
250VAC 250VAC 600VAC
Voltage 600VAC 600VAC 125 VDC* 600VAC 125VDC* 600VAC 300VAC 600VAC 300VDC
(1-200A) 300VDC* (10-60A) 300VDC* 160 VDC 600VAC 600V 300VDC 600VAC (0.5-2.25A)
Rating 450VDC 300VDC*
250VDC* 250VDC* (15-600A) (15-20A) (20–30A)
(201-600A) (70-600A)
Amp Rating 1 - 600 1 - 600 3 - 600 10 - 600 5 - 600 1 - 600 601 - 1200 0.5 - 30 0.25 - 30 0.5 - 30
Interrupting 200,000 RMS Symmetrical Amps
Rating
Current Class J Class RK5 Class RK1 Class T Class L Class CC
Limiting
UL Listed
Class J UL Listed
Guide JDDZ Class J UL Listed,
File E162363 Guide JDDZ UL Listed, Class RK, Guide JDDZ, UL Listed, Class T, Std. 248-10 UL Listed to 248.4, Class CC,
Agency CSA Certified File E162363 File E162363 Guide JDDZ, File E162363 CSA Certified, Guide JDDZ, File E162363,
HRCI-J per CSA Certified CSA Certified HRCI-R per C22.2, No. 248.12, CSA Certified HRCI-T per HRC-L C22.2
Approvals C22.2, HRCI-J per File 700489 C22.2, No. 248.12, File 53787, No. 248.10, CSA certified HRCI-MISC per C22.2
No. 248.8 C22.2, No. (LENRK CSA File 053787) Class 1422-02 & 1422-82 Class 1422-02, No. 248.4, File 700489
File 700489 248.8 File 53787
RoHS File 700489
compliant
Dimensions See product specification pages. ferrule (in): 13/32, length (in): 1-1/2
* Self-certified DC ratings
Amp Rating 0.5 to 50 0.5 to 30 0.25 to 30 0.5 to 30 0.5 to 30 0.10 to 30 0.063 to 15 0.5 to 10 0.5 to 20 0.0625 to 20 0.032 to 10 0.25 to 6.3
Interrupting 100,000 10,000 RMS Amps See specifications table on product pages
Rating RMS Amps
Current N/A N/A
Limiting
UL Listed standard 248-14 UL Listed standard 248-14
UL Listed Guide and File nos. UL Listed Card:
(ABC 0.25-20 A): Designed to UL/CSA 248-14 MDA 2/10-20A ,
UL Listed, Guide JDYX, File L Recognized Guide
U
(AGC 1/100-10 A) MDL 1/16-8A JDYX2, File E19180
JDYX and E19180 E19180 63mA-6A (Guide JDYX, File E19180
UL Recognition Guide and UL Recognition, Guide JDYX2, UL Recognized Card: Semko Approval
Agency UL Listed to 248.14, File E162443 File nos. (ABC 20-30A):(AGC File E19180, 7A-15A MDA 25-30A MDL 9-30A VDE Approval
Approvals CSA Cert. C22.2 Part 59.2, LR 700489 11-30) (Guide JDYX2, File BSI Approval
CSA Certified, File
JDYX2 and E19180 E19180) IMQ Approval
053787_C_000,
CSA Certification Record No: 63mA-6A Class 1422-01 CSA Certification Card: RoHS compliant
053787 C 000 and Class No: MDA 2/10-15A
1422 01 and 1422 30 (Class No. 1422-01)
RoHS
1/4” x 1-1/4”, 0.197” x 0.788” 1/4” x 1-1/4”, 0.197” x 0.788”
Dimensions ferrule (in): 13/32 length (in): 1-1/2 (6.3mm x 32mm) (5mm x 20mm) (6.3mm x 32mm) (5mm x 20mm)
VOLTS
EDISON
BUSSMANN
GOULD
MERSEN
LITTELFUSE
rated circuit breakers.
JDL12 12 $137.25 • All general purpose circuits with
JDL15 15 10 $131.75 inductive (high inrush) loads,
including motor and motor
JDL17-5 17.5 $137.25 branch circuits, and transformer
JDL20 20 $131.75 circuits. Also
suitable for lighting loads. 600 JDL LPJ AJT JTD
JDL25 25 $131.75
URRENT LIMITING
JDL30 30 $131.75
JDL35 35 $223.75
JDL Dimensions inches (mm)
DIMENSIONS
JDL40 40 $223.75 Cat No. JFL and JDL, Class J
JDL45 45 $223.75
2.00 lb
JDL50 50 $223.75
600V
JDL60 60 $223.75
JDL70 70 $229.50
JDL80 80 $229.50 Ampere Overall Max. Blade Barrel Blade Blade
5 1.70 lb Rating Length Dia. Length Length Thickness Width Mounting Hole Spacing
JDL90 90 $241.00 Range A B C D E F G H J K
$92.25
Thickness
110-200 5-3/4 1-5/8 1-3/8 3 3/16 1-1/8 11/16 4-3/8 3/8 9/32
Ampere
Overall
Length
Length
Length
Rating
Barrel
225-400 7-1/8 2-1/8 1-7/8 3-3/8 1/4 1-5/8 15/16 5-1/4 17/32 13/32
Width
Blade
Blade
Blade
Cat. No. JDL (Amp) 600V Cat. No. JDL (Amp) 600V
100A B
125A
200A
225A
400A
600A
Ampere 100,000
10A
15A
20A
30A
40A
50A
60A
1A
3A
5A
Rating 80,000
300
60,000
AMPERE
RATING
10 4,000
8 3,000
6 A
4 2,000
TIME IN SECONDS
3
2 1,000
800
1 600
.8
400
.6
300
.4
.3 200
.2
100 1, 000
2, 000
3, 000
4, 000
6, 000
8, 000
10, 000
20, 000
30, 000
40, 000
60, 000
80, 000
100, 000
200, 000
100
200
300
400
600
800
.1
.08
.06
.04 RMS SYMMETRICAL CURRENTS IN AMPERES
.03 A–B=ASYMMETRICAL AVAILALBE PEAK (2.3 X SYMM RMS AMPS)
.02
B
.01 100,000
1
2
3
4
6
8
10
20
30
40
60
80
100
200
300
400
600
800
1,000
2,000
3,000
4,000
6,000
8,000
10,000
80,000
INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS
60,000
RMS SYMMETRICAL CURRENT IN AMPERES 600
40,000
400
30,000
200
20,000
100
Current-Limiting Effects 10,000
60
50
8,000 40
*Prosp. Let-Thru Current (Apparent RMS Symmetrical) 6,000 30
S.C.C. JDL (600V) Fuse Ratings 4,000 20
15A 30A 60A 100A 200A 400A 600A 3,000
15
1,000 270 470 750 — — — —± 2,000
AMPERE
2, 000
3, 000
4, 000
6, 000
8, 000
10, 000
20, 000
30, 000
40, 000
60, 000
80, 000
100, 000
200, 000
100
200
300
400
600
800
JHL Features
* Note: JHL fuses can be used with GS and DURApulse • Space saving Class J dimensions allow the
drives in non-UL applications. Fuse the drive use of readily available Class J fuse blocks,
according to NEC guidelines (NEC Article 430). holders, and switches
For UL applications, GS and DURApulse drives
1 – 60 A require Class T fuses (refer to the drive’s user • Allows the lowest I2t let-through energy of
manual for details). any branch-circuit overcurrent protective
70 – 600 A device
• Works with existing and new variable
speed drives and electronic motor control-
JHL Series Class J High-Speed Drive Fuses lers
Part AMP Rated Pcs/ Weight
Pkg Part Pkg
Pcs/ Weight • Meets UL, CSA, and NEC requirements for
Rating Voltage Price Pkg (lb[kg]) Price
branch circuit protection devices
Number Pkg Number
(max) (lb[kg])
JHL1 1 $120.75 JHL1-1 $14.50 Specifications
JHL2 2 $132.25 JHL2-1 $16.50 Voltage Rating: 600 VAC; 450 VDC
JHL3 3 $120.75 JHL3-1 $16.50 Ampere Rating: 1 – 600 Amps
JHL4 4 $137.75 JHL4-1 $17.50 Interrupting Rating:
JHL5 5 $133.00 JHL5-1 $16.50 200,000 RMS Symmetrical Amps;
JHL6 6 $133.00 JHL6-1 $16.50 100,000 DC Amps
JHL8 8 1.0 $138.25 JHL8-1 0.10 $17.50 Current Limiting: Class J Fuse
[0.45] [0.05]
JHL10
JHL12
10
12
$133.00
$138.25
JHL10-1
JHL12-1
$16.50
$17.50
Agency Approvals
• UL, std 248-8, Class J, Guide JDDZ, File
JHL15 15 10 $134.00 JHL15-1 1 $16.50 E162363
JHL17P5 17.5 $133.00 JHL17P5-1 $13.75 • CSA Certified, C22.2 # 248.8, Class 1422-02,
JHL20 20 $134.00 JHL20-1 $16.50 File 700489
JHL25 25 $134.00 JHL25-1 $16.50 • RoHS compliant
JHL30 30 $134.00 JHL30-1 $16.50 CROSS REFERENCE
JHL35 35 $226.75 JHL35-1 $27.00
VOLTS
EDISON
BUSSMANN
COOPER /
MERSEN
FERRAZ /
LITTELFUSE
JHL40 40 $226.75 JHL40-1 $27.00
1.5 0.16
JHL45 45 [0.68] $226.75 JHL45-1 [0.07] $27.00
JHL50 50 600 VAC $226.75 JHL50-1 $27.00
JHL60 60 450 VDC $226.75 JHL60-1 $25.75 600 JHL DFJ HSJ –
JHL70 70 $46.75
JHL80 80 0.30 $46.75
JHL Dimensions
[0.14] A A
JHL90 90 $48.75
H H
JHL100 100 $46.75 A A K K D D
B B
JHL110 110 0.70 [0.32] $87.75 70–600A
70–600A F F B B
JHL125 125 $93.50
1–60A
1–60A J J C C E E
JHL150 150 0.8 $93.50
[0.36]
JHL175 175 $90.00 JHL Series Dimensions - Inches [mm]
JHL200 200 1 $93.50 Range A B C D E F H J K
JHL225 225 $160.00 1-30 2.25 0.81 – – – – – – –
[57.2] [20.6]
JHL250 250 $142.50 2.38 1.06
1.6 35-60 [60.5] [26.9] – – – – – – –
JHL300 300 [0.73] $142.50
4.63 1.13 1.00 2.63 0.13 0.75 3.63 0.43 0.28
JHL350 350 $149.75 70-100 [117.6] [28.7] [25.4] [66.8] [3.3] [19.1] [92.2] [10.9] [7.1]
JHL400 400 $142.50 5.75 1.63 1.38 3.00 0.19 1.13 4.38 0.43 0.28
110-200 [146.1] [41.4] [35.1] [76.2] [4.8] [28.7] [111.3] [10.9] [7.1]
JHL450 450 $215.25 7.13 2.11 1.88 3.38 0.25 1.63 5.25 0.58 0.41
2.6 225-400 [181.1] [53.6] [47.8] [85.9] [6.4] [41.4] [133.4] [14.7] [10.4]
JHL500 500 [1.18] $223.50
8.00 2.50 2.13 3.75 0.38 2.00 6.00 0.74 0.53
JHL600 600 $218.50 450-600 [203.2] [63.5] [54.1] [95.3] [9.7] [50.8] [152.4] [18.8] [13.5]
Agency Approvals
• UL Listed, Class RK5, Guide JDDZ,
File E162363
• CSA Certified HRCI-R per C22.2, No.
248.12
ECSR5 ECSR200
CROSS REFERENCE
VOLTS EDISON BUSSMANN MERS-
EN GOULD LITTELFUSE
250 ECNR FRN-R TR FLNR
600 ECSR FRS-R TRS FLSR
1. 125A
6. 125A
AMPERE AMPERE
100A
200A
400A
600A
1. 6A
2. 5A
3. 2A
10A
15A
30A
60A
. 2A
. 3A
. 4A
. 5A
. 6A
. 8A
. 1A
RATING
1A
2A
4A
5A
RATING
100 100
10
10
TIME IN SECONDS
TIME IN SECONDS
1
.1
.1
.01
100
1
.1
10
600
10, 000
100
20, 000
10
1, 000
RMS SYMMETRICAL CURRENTS IN AMPERES
1. 125A
6. 125A
AMPERE AMPERE
1. 6A
2. 5A
3. 2A
100A
200A
400A
600A
. 1A
. 2A
. 5A
. 4A
. 8A
10A
15A
30A
60A
RATING
8A
1A
2A
4A
5A
RATING
100 100
10
10
TIME IN SECONDS
TIME IN SECONDS
.1
.1
.01
100
1
.1
10
700
20, 000
100
10
1, 000
Applications Specifications
• Recommended for AC power distribution Voltage Rating:
system mains, feeders, and branch circuits LENRK Series
LENRK: 250 VAC Dual-element Time-delay Fuses
• Protection of motors and motor branch LESRK: 600 VAC
circuits Part AMP Rated Pcs/Pkg Package Price
• Type 2 protection for IEC components
Ampere Rating: Number Rating Voltage Weight
LENRK: 10–600A AC Max
• All general-purpose applications including LESRK: 5–600A LENRK10 10 $75.75
lighting, heating and other non-inductive LENRK15 15 $60.50
loads 0.50 lb
LENRK20 20 10 $60.50
CURRENT LIMITING
Class RK1 Fuses AVERAGE TIME/CURRENT CURVES
UL FUSES
LENRK (250V)
AVERAGE TIME/CURRENT CURVES
LENRK (250 VAC)
LESRK (600V)
100A
200A
400A
600A
AMPERE
15A
20A
30A
60A
LENRK (AMP) 250 VAC
20A
30A
60A
250 VAC 600
300
VAC RATING
300
200
1-1/4
6-1/4
1-1/4
6-1/4
200
Average
1/2
1/2
15/100
15/100
1-6/10
3-2/10
1-6/10
3-2/10
2-1/2
2-1/2
1/10
2/10
3/10
4/10
6/10
8/10
1/10
2/10
3/10
4/10
6/10
8/10
Time/Current
100 100
AMPERE RATING AMPERE RATING
10
12
10
12
1
4
5
8
4
5
8
300 80
300 80
60 60
Curves
200 200
40 40
100 100
3080 30
80
60 60
20 20
40 40
30 30
20 1020 10
8 8
10 610 6
8 8
6 46 4
TIME IN SECONDS
TIME IN SECONDS
TIME IN SECONDS
4 34
TIME IN SECONDS
3
3 3
22 2
2
1 1
1 1
.8 .8
.8.6 .8
.6
.6.4 .6
.4
.3 .3
.4 .4
.2 .2
.3 .3
.1 .2.1 .2
.08 .08
.06 .06
.04 .04
.1 .1
AM Page 8 .03 .03
.08 .08
.02 .06
.02 .06
.04 .04
.01 .01
.1
.2
.3
.4
.6
.8
1, 000
.1
.2
.3
.4
.6
.8
1, 000
1
2
3
4
6
8
10
20
30
40
60
80
100
200
300
400
600
800
2
3
4
6
8
10
20
30
40
60
80
100
200
300
400
600
800
.03 .03
RMS SYMMETRICAL CURRENT IN AMPERES RMS SYMMETRICAL CURRENT IN AMPERES
.02 .02
.01 .01
20
30
40
60
80
100
1, 000
2, 000
3, 000
4, 000
6, 000
8, 000
10, 000
20, 000
30
40
60
80
100
200
300
400
600
800
AVERAGE TIME/CURRENT CURVES
RMS SYMMETRICAL CURRENT IN AMPERES
RMS SY
200A
400A
600A
AMPERE
LESRK (AMP) 600VAC
100A
200A
400A
600A
AMPERE
15A
20A
30A
60A
20A
30A
60A
6-1/4
1-1/4
6-1/4
200 200
1/2
15/100
1-6/10
3-2/10
1-6/10
3-2/10
2-1/2
2-1/2
8/10
1/10
2/10
3/10
4/10
6/10
8/10
10
12
100
1
4
5
8
4
5
8
300 80 80
200 60 60
40 40
100
80 30 30
60
20 20
40
30
20 10
10
8 8
10 6
6
8
6 4
4
TIME IN SECONDS
4
TIME IN SECONDS
TIME IN SECONDS
3 3
3
2 2 2
1
.8 1 1
.6 .8 .8
.4 .6 .6
.3
.4 .4
.2
.3 .3
.1 .2
.2
.08
.06
.04
.1 .1
.03 .08 .08
.02 .06 .06
1, 000
.1
.2
.3
.4
.6
.8
1, 000
1
2
3
4
6
8
10
20
30
40
60
80
100
200
300
400
600
800
2
3
4
6
8
10
20
30
40
60
80
100
200
300
400
600
800
.03 .03
RMS SYMMETRICAL CURRENT IN AMPERES RMS SYMMETRICAL CURRENT IN AMPERES
.02 .02
.01 .01
1, 000
2, 000
3, 000
4, 000
6, 000
8, 000
10, 000
20
30
40
60
80
100
200
300
400
600
800
1, 000
2, 000
3, 000
4, 000
6, 000
8, 000
10, 000
20, 000
30
40
60
80
100
200
300
400
600
800
AMPERE
AMPERE
RATING
RATING
100,000 100,000
80,000 80,000
60,000 60,000 600
600
50,000 50,000
40,000 400 40,000 400
30,000 30,000
200 200
20,000 20,000
100 100
60 60
10,000 10,000
8,000 8,000
30 30
6,000 6,000
5,000 5,000
4,000 4,000
3,000 3,000
A A
2,000 2,000
1,000 1,000
1, 000
2, 000
3, 000
4, 000
5, 000
6, 000
8, 000
10, 000
20, 000
30, 000
40, 000
50, 000
60, 000
80, 000
100, 000
200, 000
1, 000
2, 000
3, 000
4, 000
5, 000
6, 000
8, 000
10, 000
20, 000
30, 000
40, 000
50, 000
60, 000
80, 000
100, 000
200, 000
RMS SYMMETRICAL CURRENTS IN AMPERES RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)
*Curves test data obtained at 15% short-circuit power factor when possible.
LENRK (250V)* RMS & Peak Let-Thru Currents (kA) LESRK (600V)* RMS & Peak Let-Thru Currents (kA)
Available Available
Fault Apparent Effective Let-Thru Amperes (kA) Fault Apparent Effective Let-Thru Amperes (kA)
current 30 60 100 200 400 600 current 30 60 100 200 400 600
RMS Amps I RMS Ip IRMS Ip IRMS Ip IRMS Ip IRMS Ip IRMS Ip RMS Amps I RMS Ip IRMS Ip IRMS Ip IRMS Ip IRMS Ip IRMS Ip
1,000 1 1 1 2 1 2 1 2 1 2 1 2 1,000 1 1 1 2 1 2 1 2 1 2 1 2
2,000 1 2 1 3 2 4 2 5 2 5 2 5 2,000 1 2 1 3 2 4 2 4 2 4 2 4
3,000 1 2 1 3 2 4 3 6 3 7 3 7 3,000 1 2 1 3 2 4 3 6 3 7 3 7
5,000 1 2 2 4 2 5 3 7 5 12 5 12 5,000 1 2 2 4 2 5 3 7 5 12 5 12
10,000 1 3 2 4 2 6 4 9 7 15 9 21 10,000 1 3 2 5 3 6 4 9 7 16 9 21
15,000 1 3 2 5 3 6 4 10 7 17 10 23 15,000 1 3 2 5 3 7 5 11 8 18 10 24
20,000 1 3 2 6 3 7 5 11 8 19 11 25 20,000 1 3 3 6 3 7 5 12 8 19 11 26
25,000 1 3 3 6 3 7 5 12 9 20 12 27 25,000 2 4 3 6 3 8 5 12 9 21 12 28
30,000 2 3 3 6 3 8 5 12 9 21 13 29 30,000 2 4 3 6 4 8 6 13 10 22 13 30
35,000 2 4 3 7 4 8 6 13 10 22 13 30 35,000 2 4 3 7 4 9 6 14 10 23 13 31
40,000 2 4 3 7 4 9 6 13 10 23 13 31 40,000 2 4 3 7 4 9 6 14 10 24 14 32
50,000 2 4 3 7 4 9 6 14 10 24 14 33 50,000 2 5 3 8 4 10 7 15 11 26 15 35
60,000 2 4 3 8 4 10 7 15 11 26 15 35 60,000 2 5 3 8 4 10 7 16 12 28 16 37
70,000 2 4 3 8 4 10 7 16 12 27 16 36 70,000 2 5 4 8 5 11 7 17 13 29 17 39
80,000 2 5 4 8 5 11 7 16 12 28 17 38 80,000 2 5 4 9 5 11 8 18 13 30 17 40
90,000 2 5 4 9 5 11 7 17 13 29 17 39 90,000 2 5 4 9 5 12 8 18 13 31 18 42
100,000 2 5 4 9 5 11 8 18 13 30 17 40 100,000 2 6 4 9 5 12 8 19 14 32 19 44
150,000 2 6 4 10 5 13 8 19 16 36 20 46 150,000 3 6 5 11 6 14 9 21 16 36 22 50
200,000 3 6 5 11 6 14 9 21 18 42 22 50 200,000 3 7 5 12 7 15 10 23 17 40 23 54
*"Apparent Let-Thru Amperes" values are read from "Peak Let-Through Current Curves" and the peak current value divided by 2.3
Asymmetry Factor.
Extremely Fast-Acting
Class T Fuses
EDISON TJN and TJS Class T T Series 300VAC T Series 600VAC
fuses are extremely fast-acting Extremely Fast-Acting Fuses Extremely Fast-Acting Fuses
fuses in a compact, space-sav- Part AMP Rated Pcs/ Package Part AMP Rated Pcs Package
ing size. These fuses are ideal Number Rating Voltage Pkg Weight Price Number Rating Voltage /Pkg Weight Price
as the main fuse protection for TJN1 10 0.12 lb $79.00 TJS1 10 0.33 lb $82.25
panel boards, load centers, me- 1 1
TJN1-1 1 0.02 lb $10.25 TJS1-1 1 0.02 lb $8.00
ter stacks, and AC drives.
TJN3 10 0.12 lb $82.25 TJS3 10 0.33 lb $82.25
3 3
TJN3-1 1 0.02 lb $10.25 TJS3-1 1 0.02 lb $9.50
TJN/S Features TJN6 10 0.12 lb $82.25 TJS6 10 0.33 lb $82.25
• Extremely current limiting 6 6
TJN6-1 1 0.02 lb $10.25 TJS6-1 1 0.02 lb $9.50
• No intentional time delay; opens
quickly on overload TJN10 10 0.12 lb $99.75 TJS10 10 0.33 lb $93.75
10 10
• Silver link construction TJN10-1 1 0.02 lb $12.25 TJS10-1 1 0.02 lb $11.00
provides superior component TJN15 10 0.12 lb $109.25 TJS15 10 0.33 lb $93.75
protection against fault currents TJN15-1 15 15
1 0.02 lb $13.50 TJS15-1 1 0.02 lb $11.00
• Space saving dimensions TJN20 10 0.12 lb $109.25 TJS20 10 0.33 lb $93.75
20 20
TJN20-1 1 0.02 lb $13.00 TJS20-1 1 0.02 lb $11.00
Applications TJN25 10 0.12 lb $105.00 TJS25 10 0.33 lb $93.75
25 25
• Recommended for protection TJN25-1 1 0.02 lb $13.00 TJS25-1 1 0.02 lb $11.00
of non-inductive loads such as
lighting and resistance-heating TJN30 10 0.12 lb $109.25 TJS30 10 0.33 lb $88.25
30 30
circuits TJN30-1 1 0.02 lb $13.50 TJS30-1 1 0.02 lb $10.25
• Use to protect lower interrupt- TJN35 10 0.23 lb $113.50 TJS35 10 0.82 lb $131.00
ing-rated circuit breakers when 35 35
series rated with Class T fuses TJN35-1 1 0.03 lb $13.50 TJS35-1 1 0.03 lb $14.75
• For motor protection, size at TJN40 10 0.23 lb $113.25 TJS40 10 0.82 lb $143.50
40 40
300% FLC; provides short-circuit TJN40-1 1 0.03 lb $13.50 TJS40-1 1 0.03 lb $16.00
protection only TJN45 10 0.23 lb $113.50 TJS45 10 0.82 lb $147.00
• Use for short-circuit protection 45 45
of AC drives TJN45-1 1 0.03 lb $13.50 TJS45-1 1 0.03 lb $17.75
TJN50 10 0.23 lb $113.50 TJS50 10 0.82 lb $133.00
50 50
TJN50-1 $13.50 TJS50-1
Specifications TJN60
300 VAC 1
10
0.03 lb
0.23 lb $109.25 TJS60
600 VAC 1
10
0.03 lb $15.25
0.82 lb $131.00
Voltage Rating: TJN: 300 VAC 60 60
TJN60-1 1 0.03 lb $13.50 TJS60-1 1 0.03 lb $14.25
TJS: 600 VAC
TJN70 5 0.36 lb $64.50 TJS70 5 0.51 lb $95.75
70 70
Ampere Ratings: 1–600 Amps TJN70-1 1 0.11 lb $15.25 TJS70-1 1 0.11 lb $21.75
Interrupting Rating: 200,000 RMS TJN80 5 0.36 lb $68.75 TJS80 5 0.51 lb $109.25
80 80
Symmetrical Amps TJN80-1 1 0.11 lb $16.50 TJS80-1 1 0.11 lb $25.25
S elf-Certified Voltage Ratings TJN90 5 0.36 lb $68.75 TJS90 5 0.51 lb $120.75
90 90
(DC): TJN90-1 1 0.11 lb $16.50 TJS90-1 1 0.11 lb $27.75
TJN (15–600): 160 VDC
TJS (15–400): 300 VDC TJN100 5 0.36 lb $63.50 TJS100 5 0.51 lb $109.25
100 100
TJN100-1 1 0.11 lb $15.25 TJS100-1 1 0.11 lb $25.25
Self-Certified Interrupting
Ratings (DC): TJN110 110 1 $18.75 TJS110 110 1 $26.50
TJN (15–600): 20,000 Amps DC TJN125 125 1 $18.75 TJS125 125 1 $26.50
TJS (15–400): 10,000 Amps DC TJN150 150 1 0.14 lb $20.75 TJS150 150 1 0.19 lb $26.50
Current Limiting: Class T Fuse TJN175 175 1 $20.75 TJS175 175 1 $27.50
TJN200 200 1 $20.75 TJS200 200 1 $27.50
Agency Approvals TJN225 225 1 $48.25 TJS225 225 1 $64.50
• UL Listed, Class T, Guide JDDZ,
File E162363 TJN250 250 1 $48.25 TJS250 250 1 $64.50
• CSA Certified HRCI-T per C22.2, TJN300 300 1 0.25 lb $49.00 TJS300 300 1 0.46 lb $71.75
No. 248.12, File # 53787 TJN350 350 1 $42.75 TJS350 350 1 $73.75
• CE TJN400 400 1 $38.50 TJS400 400 1 $77.00
• REACH TJN450 450 1 $56.25 TJS450 450 1 $151.75
TJN500 500 1 0.44 lb $60.00 TJS500 500 1 0.85 lb $156.00
TJN600 600 1 $62.50 TJS600 600 1 $167.50
Extremely Fast-Acting
Class T Fuses
CROSS REFERENCE
VOLTS
EDISON
BUSSMANN
GOULD
MERSEN
LITTELFUSE
300 TJN JJN A3T JLLN
600 TJS JJS A6T JLLS
B1 B1 B2 F
1A to 60A TJN
1A to 30A TJS 35A to 60A TJS
G H J E
70A to 600A
Hole Spac-
Fuse Type
Maximum
Thickness
Mounting
Diameter
Current
Overall
Length
Length
Length
Rating
Barrel
Width
Blade
Blade
Blade
ing
Range A B1 B2 C D E F G H J
(A) (in [mm])
0.41
1-30 [10.4]
0.88 n/a (no blades)
[22.4] 0.56
35-60 [14.2]
TJN (300 VAC)
Extremely Fast-Acting
Class T Fuses
TJN (300 VAC)Trip Curves
TJS Time-Current Characteristic Curves
Current Limitation Curves – Average Melt
B
100A
200A
400A
600A
400,000 AMPERE
INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS
15A
30A
60A
AMPERE
RATING
RATING
300
100,000
100
600
400
200
10,000 100
60
30
15
10
1,000
TIME IN SECONDS
A
200
100
1,000
10,000
100,000
200,000
0.1
0.01
20
100
1,000
10,000
CURRENT IN AMPERES
200A
400A
500A
800A
B
10A
15A
30A
60A
400,000
INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS
1A
3A
5A
RATING
AMPERE
RATING
300
100,000 100
600
400
200
10,000 100 10
60
TIME IN SECONDS
30
1
1,000
A
200 0.1
100
1,000
10,000
100,000
200,000
10
100
1,000
10,000
CURRENT IN AMPERES
Class L Fast-Acting
Current Limiting Fuses
Edison LCU UL Class L fuses are particularly
suited for protection of circuit breakers with lower
Specifications
interrupting ratings and non-inductive loads such Voltage Rating: 600 VAC (or less)
as lighting and heating circuits. 99% pure silver Ampere Rating: 601-1200 Amps
links provide low watt loss and low operating
Interrupting Rating:
temperature at normal current levels.
200,000 RMS Symmetrical Amps;
Applications Current Limiting: Class L Fuse
• Circuit breakers Mounting: Bolt mount
LCU601 • Drive protection Note: Fuse blocks not sold by AutomationDirect.com
• Meets UL, NEC and CSA requirements for branch
and feeder protection Agency Approvals
• UL Listed, Std. 248-10, E162363, JDDZ
Class L Features • CSA Certified, HRC-L C22.2 No. 248.10, Class
• Fast-acting, short circuit protection 1422-02, File 53787
• Allows low I2t let-through energy of any branch • RoHS compliant, CE, Reach
circuit overcurrent protective device
• High grade silica-sand filler accelerates response To obtain the most current agency approval information,
of fuse to short circuits by having a quenching see the Agency Approval Checklist section on the specific
effect upon the fuse arc.
LCU1200 part number's web page.
• O-ring seals maximize pressure build-up during
current limiting actions and ensure filler retention.
• Silver-plated micro-peened terminals provide
high electrical conductivity, minimize heat genera-
tion, and keep fuses and switches cool.
• Selective coordination (blackout prevention)
• Glass melamine tube
• Silver-plated end bells LCU Series Class L Fast-Acting Fuses
• No fuse reducers required. Part AMP Rated Voltage Pcs/ Weight Price
Number Rating (max) Pkg lb [kg]
Cross Reference LCU601 601 $322.00
LCU650 650 3.64 $366.00
Edison Bussmann Mersen Littelfuse [1.65]
LCU700 700 $309.50
LCU KTU A4BY LDC 600VAC 1
LCU800 800 $305.25
LCU1000 1000 4.04 $293.50
LCU601-800 LCU1000-1200
Dimensions
Amp A B C
1000-1200 2-25/64 3/8 2
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
1200
800
601
RATING
10A
15A
20A
RATING
1A
2A
3A
5A
8A
HCLR2 2 $73.25 300
HCLR3 3 $73.25
HCLR3-5 3.5 $98.25 100
80
HCLR4 4 $77.75 60
HCLR5 5 $73.25 40
10 0.2 lb
HCLR6 6 $76.50 30
HCLR7 7 $89.25 20
HCLR8 8 $77.75
HCLR9 9 $98.25 10
8
HCLR10 10 $73.25 6
HCLR12 12 $73.75 4
TIME IN SECONDS
HCLR15 15 $73.25 3
HCLR20 20 $73.25 2
HCLR25 25 $77.75
1
HCLR30 30 $73.25 0.8
0.6
0.4
DIMENSIONS 0.3
0.06
0.04
0.02
EDISON BUSSMANN GOULD LITTELFUSE
HCLR KTK-R ATMR KLKR 0.01
1
3
4
6
8
10
20
30
40
60
80
100
200
300
400
7. 5
0.75 $107.75
0.5
RATING
1
5
3
100
HCTR1 1 $85.50
80
HCTR1-25 1.25 $107.75 60
HCTR3 3 $86.25
HCTR3-5 3.5 $107.75 10
10 0.2 lb 8
HCTR4 4 $93.75
6
HCTR5 5 $87.25
4
HCTR6 6 $96.75
TIME IN SECONDS
3
HCTR7-5 7.5 $103.25
2
HCTR8 8 $96.75
HCTR10 10 $93.75
1
HCTR15 15 $87.75 0.8
0.6
HCTR20 20 $91.25
0.4
HCTR25 25 $91.25
0.3
HCTR30 30 $91.25
0.2
DIMENSIONS 0.1
0.08
Amps Ferrule (in) Length (in) 0.06
0.25 - 30 13/32 1-1/2 0.04
0.03
0.02
CROSS REFERENCE
0.01
EDISON BUSSMANN GOULD LITTELFUSE
0.4
0.6
0.8
1
3
4
6
8
10
20
30
40
60
80
100
200
100000
200000
10000
20000
50000
1000
2000
5000
100
200
500
10
20
30
50
10000 70
7000
30 AMP
5000 20 AMP
15 AMP
10 AMP
3000 7.5 AMP
3 AMP
2000
1.5 AMP
1000
700
500
300
200
100
70
50
30
20
10
10
20
30
50
70
100
200
500
1000
2000
5000
10000
20000
50000
100000
200000
3.5
4.5
10
12
15
20
25
30
RATING
3
4
6
8
1
Prospective
Short- Circuit 1.25A 2.8A 15A 20A 25A 30A
Current* 100
1000 100 135 240 305 380 435
3000 140 210 350 440 575 580
5000 165 255 420 570 690 710
10,000 210 340 540 700 870 1,000
20,000 260 435 680 870 1,090 1,305
30,000 290 525 800 1,030 1,300 1,520 10
DIMENSIONS 0.1
Amps Ferrule (in) Length (in)
0.5 - 30 13/32 1-1/2
CROSS REFERENCE
EDISON BUSSMANN GOULD LITTELFUSE 0.01
0.1
10
100
1000
10A
15A
20A
RATING
1A
2A
3A
5A
8A
300
MCL1 1 $73.50
200
MCL1-5 1.5 $79.75
MCL2 2 $73.50
100
MCL2-5 2.5 $91.75 80
MCL3 3 $73.50 60
30
MCL4 4 $75.50
MCL5 5 $73.50 20
MCL6 6 $71.25
10 0.2 lb 10
MCL8 8 $75.50 8
MCL10 10 $73.50 6
MCL12 12 $86.50 4
TIME IN SECONDS
MCL15 15 $73.50 3
MCL20 20 $73.50 2
MCL25 25 $73.50
1
MCL30 30 $73.50
0.8
0.2
*Note: Max continuous load 25A. Not UL.
0.1
0.08
DIMENSIONS 0.06
0.03
0.5 - 50 13/32 1-1/2
0.02
CROSS REFERENCE
0.01
1
3
4
6
8
10
20
30
40
60
80
100
200
300
400
10A
15A
20A
30A
1A
3A
RATING
MOL1 1 $15.25 100
80
MOL1-5 1.5 $19.75
60
MOL2 2 $15.25 50
40
MOL2-5 2.5 $19.75 30
MOL3 3 $15.25
20
MOL4 4 $19.75
MOL5 5 10 0.2 lb $15.25 10
MOL6 6 $15.25 8
6
MOL8 8 $16.00 5
MOL10 10 $12.25 4
TIME IN SECONDS
3
MOL15 15 $13.50
2
MOL20 20 $18.50
MOL25 25 $19.25
1
MOL30 30 $17.00 0.8
0.6
0.5
0.4
0.3
DIMENSIONS 0.2
800
1
3
4
5
6
8
10
20
30
40
60
80
100
200
300
400
500
600
7. 5
0.5
RATING
1
5
3
100
MEQ1-5 1.5 $77.00
80
MEQ2 2 $73.75 60
MEQ2-5 2.5 $77.00
40
MEQ3 3 $73.75 30
MEQ3-5 3.5 $83.25
20
MEQ4 4 $73.75
MEQ4-5 4.5 $89.25 10
10 0.2 lb
MEQ5 5 $73.75 8
6
MEQ6 6 $73.75
4
MEQ7 7 $77.00
TIME IN SECONDS
3
MEQ8 8 $73.75
2
MEQ10 10 $73.75
MEQ12 12 $73.75
1
MEQ15 15 $73.75
0.8
MEQ20 20 $73.75 0.6
MEQ25 25 $73.75
0.4
MEQ30 30 $73.75 0.3
0.2
DIMENSIONS
0.1
Amps Ferrule (in) Length (in) 0.08
0.03
0.6
0.8
1
3
4
6
8
10
20
30
40
60
80
100
200
General Purpose
Midget Class MEN Fuses
Features MEN Specifications
• Compact dimensions
• Fiber tube construction Time-Delay
• Dual-element construction allows Voltage Rating: MEN - 250 VAC
harmless inductive surges to pass without Ampere Rating: 0.5 - 30 Amps
opening
Interrupting Rating: 10,000 RMS Amps @ 125V
0.5
MEN-6 0.6 $36.25 RATING
1
100
MEN1 1 $34.25 80
60
MEN1-4 1.4 $43.75 50
MEN1-5 1.5 $38.50 40
30
MEN2 2 $31.25
20
MEN2-5 2.5 $35.00
MEN3 3 $32.75
10
MEN3-5 3.5 $33.25 8
MEN4 4 $32.75 6
10 0.2 lb 5
MEN5 5 $31.25 4
3
TIME IN SECONDS
MEN6 6 $35.00
MEN7 7 $33.25 2
MEN8 8 $32.75
1
MEN10 10 $31.25
0.8
MEN12 12 $35.50 0.6
0.5
MEN15 15 $32.75
0.4
MEN20 20 $33.00 0.3
MEN30 30 $33.00
0.1
0.08
DIMENSIONS 0.06
0.05
Amps Ferrule (in) Length (in) 0.04
0.03
0.5 - 30 13/32 1-1/2
0.02
3
4
5
6
8
10
20
30
40
50
60
80
100
200
300
400
500
600
800
Small Dimension
Fast-Acting ABC Fuses
Applications Agency Approvals
• Supplemental protection for electronic • UL Listed product meets standard 248-14
applications • UL Listed Guide and File numbers
(ABC 0.5-15A): JDYX and E19180
ABC Specifications • UL Recognition Guide and File numbers
(ABC 20-30A): JDYX2 and E19180
Voltage Rating: ABC - See table below • CSA Certification Record No: 053787,
Class No: 1422 01 and 1422 30
Ampere Rating: 0.5 - 30 Amps
• RoHS
Interrupting Rating: See table below
Features
• Compact dimensions 1/4” x 1-1/4”, Environmental Data
(6.3 mm x 32 mm) • Shock: 0 .5A - MIL-STD-202, Method 213,
• Ceramic tube construction Test Condition I;
• Fast-acting 1A thru 30A - MIL-STD-202,
• Fit on our DN-F6 fuse terminal blocks sold Method 207, (HI Shock)
in Wiring Solutions section of this catalog • Vibration: 0.5A thru 30A - MIL-STD-202,
• RoHS Compliant Method 204, Test Condition C
(except 5g, 500 HZ)
* Interrupting ratings were measured at 70% – 80% power factor on AC, and at a time constant described in UL 198L.
** Typical Melting I2t (A2sec) – measured at listed interrupting rating and rated voltage (at 70% to 80% power factor on AC).
*** Typical Voltage Drop – measured at 25°C ± 3°C ambient temperature at rated current.
For mounting and wiring ABC fuses, see our DN-F6 Series fuse CROSS REFERENCE
blocks in the Terminal Blocks and Wiring Solutions section. OLD EDISON BUSSMANN MERSEN LITTELFUSE
GOULD
BBC ABC GAB 314
Small Dimension
Fast-Acting ABC Fuses
TIME CURRENT CURVE
CURRENT IN AMPERES
10
15
20
25
30
1
8
Time in seconds
CURRENT IN AMPERES
Small Dimension
Fast-Acting AGC Fuses
Applications Environmental Data
• Supplemental protection for electronic Shock: 0 .1A thru 0.75A - MIL-STD-202,
applications Method 213, Test Condition I;
1 A thru 30A - MIL-STD-202,
AGC Specifications Method 207, (HI shock)
Vibration: 0.1A thru 30A - MIL-STD-202,
Voltage Rating: AGC - See table below Method 204, Test condition A
(except 5g, 500 HZ)
Ampere Rating: 0.10 - 30 Amps
Interrupting Rating: See table below Agency Approvals
• UL Listed product meets standard 248-14
Features • UL Listed Card: (0.1-10A): JDYX E19180
• Compact dimensions 1/4” x 1-1/4”, • UL Recognition Card: (15-30A): JDYX2
(6.3 mm x 32 mm) E19180
• Glass tube construction, with nickel • CSA Certification 053787
plated brass endcaps (Class No. 1422 01 and 1422 30
• Fast-acting • RoHS
• RoHS Compliant
CROSS REFERENCE
For mounting and wiring AGC fuses, see our DN-F6 Series fuse
OLD EDISON BUSSMANN MERSEN
blocks in the Terminal Blocks and Wiring Solutions section. GOULD LITTELFUSE
BGC AGC GGC 312
Small Dimension
Fast-Acting AGC Fuses
1-1/2
2-1/2
1/16
1/10
2/10
3/10
3/8
1/8
1/4
1/2
3/4
3
4
1
2
RRENT CURVE
TIME IN SECONDS
ENT IN AMPERES
TIME CURRENT CURVES
1-1/2
2-1/2
3/8
1/2
3/4
3
4
1
Dimensions
(mm/inches)
TIME IN SECONDS
5x20mm Glass
Fast-Acting GMA Fuses
Features GMA Specifications
• Compact dimensions, 0.197” x 0.788” (5mm Voltage Rating: GMA - See table below
x 20mm)
• Glass tube construction with Ampere Rating: 0.063 - 15 Amps
nickel-plated brass end caps Interrupting Rating: See table below
• Fast-acting, low breaking capacity
• RoHS Complian Agency Approvals
• Designed to UL/CSA 248-14
Applications • UL Listed, Guide JDYX, File E19180
63 mA-6A
• Supplemental protection for electronic
applications • UL Recognition, Guide JDYX2, File E19180,
7A-15A
• CSA Certified, Class 1422-01, File 053787,
63 mA-6A
• RoHS
*Note: Interrupting ratings for 63 mA - 6A were measured at 70% - 80% power factor on AC; interrupting ratings
for 7A - 15A were measured at 100% power factor on AC.
** Typical pre-arcing I2t (A2Sec) - measured at listed interrupting rating and rated voltage (at 70% to 80%
power factor on AC)
*** Typical Voltage Drop - measured at 20°C ambient temperature at rated current.
CROSS REFERENCE
For mounting and wiring GMA fuses, see our DN-F10 Series fuse
blocks in the Terminal Blocks and Wiring Solutions section. OLD EDISON BUSSMANN MERSEN
GOULD LITTELFUSE
BMA GMA GGM 235
5x20mm Glass
Fast-Acting GMA Fuses
1.25A
2A
3A
1.5A
2.5A
AMPERE
1A
4A
5A
6A
RATING
100
10
TIME IN SECONDS
.1
.01
.4
10
100
200
CURRENT IN AMPERES
*Note: Interrupting ratings for 63 mA - 6A were measured at 70% - 80% power factor on AC; rnterrupting ratings
for 7A - 15 A were measured at 100% power factor on AC.
** Typical pre-arcing I2t (A2Sec) - measured at listed interrupting rating and rated voltage.
*** Typical Voltage Drop - measured at 20°C ambient temperature at rated current.
CROSS REFERENCE
For mounting and wiring GMC fuses, see our DN-F10 Series fuse
OLD EDISON BUSSMANN MERSEN
blocks in the Terminal Blocks and Wiring Solutions section. GOULD LITTELFUSE
none GMC GSC none
100mA
200mA
315mA 300mA
400mA
2.5A
3.5A
6.3A
1A
4A
8A
125mA
150mA
250mA
500mA
750mA
800mA
62mA
80mA
1.5A
1.6A
AMPERE
10A
2A
3A
5A
6A
7A
RATING
100
10
TIME IN SECONDS
.1
.01
.1
10
100
CURRENT IN AMPERES
Dimensions
GMC Electrical Characteristics
(mm)
Rated Current % of Amp Rating Opening Time
(± (±
100 None
0.5A to 10 Amps 135 60 minutes maximum
200 2 minutes maximum
5.2mm
(+0.1/-0.2)
Small Dimension
Time-Delay MDA Fuses
Features Environmental Data
• Compact dimensions 1/4” x 1-1/4”, Shock: 0 .5A : MIL-STD-202, Method 213,
(6.3 mm x 32 mm) Test Condition I;
• Ceramic tube construction with 1 A thru 20A: MIL-STD-202,
nickel-plated brass end caps Method 207, (HI shock)
• Time-delay Vibration: 0.5A: MIL-STD-202, Method 201;
• RoHS 0 .5A thru 20A: MIL-STD-202,
Method 204, Test condition C
(except 5g, 500 HZ)
Applications
• Supplemental protection for electronic Agency Approvals
applications • UL Listed product meets standard 248-14
• UL Listed Card: MDA 0.5-20A
MDA Specifications (Guide JDYX, File E19180
• CSA Certification File 053787: MDA 0.5-15
Voltage Rating: MDA - See table below (Class No. 1422-01)
Ampere Rating: 0.5 - 20 Amps • RoHS
Interrupting Rating: See table below
For mounting and wiring MDA fuses, see our DN-F6 Series fuse CROSS REFERENCE
blocks in the Terminal Blocks and Wiring Solutions section. OLD EDISON BUSSMANN MERSEN
GOULD LITTELFUSE
BDA MDA None 326
Small Dimension
Time-Delay MDA Fuses
TIME CURRENT CURVE
CURRENT IN AMPERES
3-2/10
6-1/4
1/4
1/2
10
12
15
20
25
30
4
5
1
2
TIME IN SECONDS
TIME IN SECONDS
CURRENT IN AMPERES
Small Dimension
Time-Delay MDL Fuses
Applications 201;
0.25A thru 20A: MIL-STD-202,
• Supplemental protection for electronic Method 204, Test condition C
applications (except 5g, 500 HZ)
CROSS REFERENCE
For mounting and wiring MDL fuses, see our DN-F6 Series fuse
OLD EDISON BUSSMANN MERSEN
blocks in the Terminal Blocks and Wiring Solutions section. GOULD LITTELFUSE
BDL MDL GDL 313
Small Dimension
Time-Delay MDL Fuses
10000
2000
3000
4000
5000
6000
7000
8000
9000
1000
100
200
300
400
500
600
700
800
900
10
20
30
40
50
60
70
80
90
1
5
6
7
8
9
1000 1000
900 900
800 800
700 700
600 600
500 500
1-6/10
400 400
1-1/2
300 300
2
200 200
3-2/10
1-1/4
6-1/4
10
15
20
25
30
40
5
100 100
90 90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
9 9
8 8
TIME IN SECONDS
TIME IN SECONDS
7 7
6 6
5 5
4 4
3 3
2 2
1 1
.9 .9
.8 .8
.7 .7
.6 .6
.5 .5
.4 .4
.3 .3
.2 .2
.1 .1
.09 .09
.08 .08
.07 .07
.06 .06
.05 .05
.04 .04
.03 .03
.02 .02
.01 .01
1
5
6
7
8
9
10
20
30
40
50
60
70
80
90
100
200
300
400
500
600
700
800
900
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
CURRENT IN AMPERES
5x20mm Fast-Acting
S500 Series Fuses
Features Agency Approvals
• Compact dimensions, 0.197” x 0.788” • UL Recognized Card: (0.5A-10A)
(5 mm x 20 mm) Guide JDYX2, File E19180
• Glass tube construction with • CSA Component Acceptance File 53787
nickel-plated brass end caps • Semko Approval 160 mA-400 mA and
• Fast-acting, low breaking capacity 800 mA-10A
• Designed to IEC 60127-2 (32mA-6.3A) • VDE Approval 0.32A-10A
• RoHS Compliant • BSI Approval 0.32A-10A
• IMQ Approval 0.32A-10A
Applications • RoHS
•
Supplemental protection for electronic
applications
S500 Specifications
Voltage Rating: See table below
Ampere Rating: 0.32 - 10 Amps
Interrupting Rating: See table below
CROSS REFERENCE
For mounting and wiring S500 fuses, see our DN-F10 Series fuse
blocks in the Terminal Blocks and Wiring Solutions section. OLD EDISON BUSSMANN MERSEN
GOULD LITTELFUSE
GDB/BDB GDB GSB 217
5x20 mm Fast-Acting
S500 Series Fuses
TIME CURRENT CURVE
Dimensions
mm (inches)
S500 Electrical Characteristics
(0.394”) (0.788”)
IN 1.5 In min 2.1 In max 2.75 In min 2.75 In max 4 In min 4 In max 10 In max
0.32A to 6.3A 60 min 30 min 50 ms 2 sec 10 ms 300 ms 20 ms
(0.197”)
5x20 mm Time-Delay
S506 Series Fuses
Features • UL Recognized Card: (0.25A-10A)
Guide JDYX2, File E19180
• Compact dimensions, 0.197” x 0.788” • CSA Component Acceptance File 053787
(5 mm x 20 mm)
• Semko Approval 0.25-10A
• Glass tube construction with
nickel-plated brass end caps • VDE Approval 0.25-10A
• Time-delay, low breaking capacity • BSI Approval 0.25-10A
• Designed to IEC 60127-2 (32 mA-10A) • IMQ Approval 0.25-10A
• RoHS Compliant • MITI Approval, 0.25-10A
• RoHS
Applications
• Supplemental protection for electronic
applications
S506 Specifications
Voltage Rating: See table below
Ampere Rating: 0.25 - 6.3 Amps
Interrupting Rating: See table below
Agency Approvals:
CROSS REFERENCE
For mounting and wiring S506 fuses, see our DN-F10 Series fuse
blocks in the Terminal Blocks and Wiring Solutions section. OLD EDISON BUSSMANN MERSEN LITTELFUSE
GOULD
GDC/BDC GDC GDG 218
5x20 mm Time-Delay
S506 Series Fuses
Dimensions
mm (inches)
(0.197”)
Wire:
Cu – 75°/90°C [ 167°/194°F] Clear IP20 finger-safe cover
(sold separately)
Al – 75°C [167°F]
Ring or Fork terminal to fit a #10-32 screw
Modular dove-tail
design for tool-less
snap together assembly Test probe holes
Compact Footprint
RM25030-2SR 1 $12.50 30 2 18-10 AWG (Cu) 18-10 AWG 20 [2.3] 0.15 [0.07] CVR-RH-25030 CVRI-RH-25030 1
$5.25 $6.50
RM25030-3SR 1 $18.75 250V 3 0.25 [0.12]
RM25060-1CR 1 $14.75 AC/DC 1 3-2 AWG 50 [5.6] 0.15 [0.07]
Box Lug
RM25060-2CR 1 $28.50 60 2 14-2 AWG (Cu) 6-4 AWG 45 [5.1] 0.30 [0.14] CVR-RH-25060 CVRI-RH-25060 1
8-2 AWG (Al) 8 AWG 40 [4.5] $6.25 $7.25
RM25060-3CR 1 $36.50 3 14-10 AWG 35 [4.0] 0.45 [0.22]
RM60030-1SR 1 $16.75 1 0.15 [0.07]
Screw
RM60030-2SR 1 $27.00 30 2 18-10 AWG (Cu) 18-10 AWG 20 [2.3] 0.30 [0.14] CVR-RH-60030 CVRI-RH-60030 1
$5.25 $6.75
RM60030-3SR 1 $33.25 600V 3 0.45 [0.22]
RM60060-1CR 1 $21.25 AC/DC 1 3-2 AWG 50 [5.6] 0.25 [0.12]
Box Lug
RM60060-2CR 1 $35.75 60 2 14-2 AWG (Cu) 6-4 AWG 45 [5.1] 0.45 [0.22] CVR-RH-60060 CVRI-RH-60060 1
8-2 AWG (Al) 8 AWG 40 [4.5] $6.25 $7.25
RM60060-3CR 1 $46.75 3 14-10 AWG 35 [4.0] 0.70 [0.30]
¹ Open fuse indication requires 90V minimum and closed circuit to operate.
RM25030
RM25060
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
RM60030
Pressure plate
RM60060
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
Specifications
Construction: Thermoplastic
UL Flammability: 94V-0
Voltage Ratings:
R250: 250 Volts AC; R600: 600 Volts AC
Ampere Ratings: 0.10 - 600 Amps
R60030-1SR Short-circuit current Rating: 200,000 RMS
Symmetrical Amps
R250 Series Fuse Blocks (250V) R600 Series Fuse Blocks (600V)
Poles
Poles
Maximum Fig # Pcs/ Wt. Price Maximum Fig # Pcs/ Wt. Price
Part Number Amps Part Number Amps
Wire Size Pkg (lbs.) Wire Size Pkg (lbs.)
R25030-1SR 1 1 0.10 Retired R60030-1SR 1 13 0.24 Retired
R25030-2SR 0.1 to 30 2 #10-18 Cu 2 0.25 Retired R60030-2SR 0.1 to 30 2 #10-18 Cu 14 0.44 $26.50
only
R25030-3SR 3 3 0.30 Retired R60030-3SR 3 15 0.40 Retired
R25060-1CR 1 4 0.23 Retired R60060-1CR 1 16 0.30 $20.50
R25060-2CR 31 to 60 2 #2-14 Cu 5 0.44 Retired R60060-2CR 31 to 60 2 #2-14 Cu 17 0.60 $34.50
#2-8 Al #2-8 Al
R25060-3CR 3 6 0.45 Retired R60060-3CR 3 18 0.85 Retired
R25100-1CR 1 7 0.60 Retired R60100-1CR 1 19 1.00 $44.00
61 to
R25100-2CR 61 to 100 2 1/0-8 Cu-Al 8 1 1.00 Retired R60100-2CR 100 2 1/0-8 Cu-Al 20 1 1.50 $64.00
R25100-3CR 3 9 1.50 Retired R60100-3CR 3 21 2.30 Retired
R25200-1CR 1 250MCM-6 2.20 $90.00 R60200-1CR 101 to 1 250MCM-6 0.50 $91.00
101 to 200
R25200-3CR 3 Cu-Al See 5.30 $270.00 R60200-3CR 200 3 Cu-Al See 4.95 $258.00
Table 1
R25400-1CR 1 500MCM-4 below 2.90 $247.00 R60400-1CR 201 to 1 500MCM-4 Table 2 4.10 $219.00
201 to 400 below
R25400-3CR* 3 Cu-Al then 1070 $737.00 R60400-3CR* 400 3 Cu-Al 9.85 $617.00
refer to then refer
R25600-1CR 1 5.80 $300.00 R60600-1CR 1 (2) 500MCM- to Figure # 7.50 $348.00
(2) 500MCM- Figure # 401 to
401 to 600
R25600-3CR* 3 4/ 0 Cu-Al 20.70 $969.00 R60600-3CR* 600 3 4/0 Cu-Al 17.30 $929.00
* Not UL
* Not UL
4.25 1.25
[108] [31.8]
1.5
[38.1]
0.28" DIA. x
0.5" C'BORE
7.36
[187] 3.125
2.38
[79.4]
[60.5]
2.125
[54]
9
[228.6]
Figure 10 Figure 11
B G
H E F
A C
.34 [8.6] DIA.
HOLE
THROUGH
Figure 12
1.56 [39.6]
Figure 13 Figure
3.38 14 Figure
4.94 15
1.56 [39.6]
[85.9] [125.5]
2.06 1.81 0.59 1.56 1.56
600V, 31 Amp to 60 Amp
[52.3] 1.56
[46] 0.59 [39.6] [15] [39.6] [39.6]
0.25 [15] 0.62
[6.4] 0.62 3.38
[15.7] 0.62 4.94
[15.7] [85.9] [15.7] [125.5]
2.06 1.81 0.59
[52.3] 1.56 1.56 1.56 0.28" DIA. x
[46] 0.59 [39.6] [15] [39.6] 0.5" C'BORE
[39.6]
0.25 [15] 0.62 [7.1 x 12.7]
[6.4] 0.62 0.62
[15.7]
[15.7] [15.7]
0.28" DIA. x
0.5" C'BORE
7.36
[7.1 x 12.7]
3.125
[187] 2.38 [79.4]
[60.5]
7.36 3.125
[187] 2.38 [79.4]
2.125 [54][60.5]
2.38
2.22 4.03 5.84
[56.4] [102.4] [148] 2.125 [54]
[60.5]
0.67 1.81 1.81 1.81
0.34 0.67
0.88 [17] [46] [46] [46]
[8.6] [17]
Figure 16[22.4] 0.88 Figure 17 0.88 Figure 18
[22.4] [22.4]
2.38
2.22 4.03 5.84
[56.4] 0.28x0.5 [102.4] [148]
[60.5]
0.34
600V, 61 Amp to
[7.1 100
x 12.7] Amp
0.67 1.81
0.28x0.5
[7.1 x 12.7] 0.67
1.81
0.28x0.5
1.81 [7.1 x 12.7]
0.88 [17] [46] 4.03 [46] [46] 5.84
[8.6] [102.4] [17]
[22.4] 0.88 0.67
[148]
2.38 2.22 1.81 0.88 0.67 1.81
9.5 [60.5] [56.4] [22.4] [17] [46] [22.4] [17] [46]
[241.3] 0.69 0.88 0.88 0.88
0.28x0.5 [22.4] 4.25 [108]
[17.4] [7.1 x 12.7] [22.4] 0.28x0.5 [22.4] 0.28x0.5
[7.1 x 12.7] [7.1 x 12.7]
9.5 4.25
[241.3]
[108]
2.63 [67]
2.63
[67]
250V,
600V, 101101A to600
Amp to 600A;
Amp 600V, 101A to 600A
600V, 101 Amp to 200 Amp
B 9.0
H G [229]
E 8.0 3.15
K F
[203.2] [80]
6.5 .75
[165] [19.1]
0.34
DIAMETER
9.58
0.75" 0.34 [8.6] [243.3]
C A
C'BORE DIAMETER
0.75 [19.1] DIA. 5.5
C'BORE 3.0 [140]
.50 [12.7] Deep [76.2]
2.04
FIGURE 10. [52]
Figure 22 Figure 23
600V, 201 Amp to 400 Amp 600V, 401 Amp to 600 Amp
15.26 4.987
11.63 4.02 [387.6]
[295.4] [102.1] [127]
9.25 11.0 1.00
1.00 2.13
1.19 [235] [279.4] [25.4]
[25.4] [54.1]
[30.2]
0.34 [8.6]
0.34 [8.6] DIAMETER 14.00
DIAMETER 0.75 [19.1] DIA. [356]
12.00 C'BORE
0.75 [19.1] DIA. [304.8] .67 [17] Deep
C'BORE 8.00
.67 [17] Deep 7.00
[203.2]
[178]
2.5 3.00
[63.5]
[76.2]
Figure 24 Figure 25
Note: All dimensions shown in inches [mm]
Specifications
Construction: Glass Polyester; Phenolic
on 600V
UL Flammability: 94V-O
Ratings:
T300: 300 VAC; 30–600A
T600: 600 VAC; 30–600A
Short-circuit Current Rating:
200,000 RMS Symmetrical
Amps
Class T Fuse Blocks
Poles Terminal Wire Range Fig # Wt. Pcs
Part Number Volts Amps
Agency Approvals Type (AWG) (lb) /Pkg Price
• UL Listed, Guide IZLT, File E14853 T30030-2SR 2 0.3 $18.00
0.5 to 30 screw 10–18 Cu (only)
• CSA, Class 6225-01, File 47235 T30030-3SR 3 0.4 $18.00
1
• CE T30060-2CR 2 0.4 $22.00
31 to 60 2–14 Cu/Al
• REACH T30060-3CR 3 0.5 $34.75
1.63 [41.4] A
1.20
0.72 [18.3] 0.69 [30.5] B Figure 1: 300V 1/2A to 60A
0.16 [4.06] [17.5] X Z
T30030-xSR T30060-xCR X Z
(screw terminals) (box lug terminals) 0.50 [12.7]
Section X-X Section Z-Z 0.20 [5.08]
C
0.22 DIAMETER
[5.6]
0.33
[8.4] 0.5 C'BORE
[12.7]
3.18 1.563
[80.8] [39.7]
Figure 2:
600V 1/2A to 30A
1.43
[36.2]
Dimensions
= in [mm]
0.22 DIAMETER
[5.6]
0.5 C'BORE
2.94 1.63 [12.7]
[74.7] [41.4]
1.47 Figure 3:
[37.3] 600V 131A to 60A
Dimensions
= in [mm]
0.22 DIA.
[5.6]
0.52 C'BORE
4.81 2.25 [13.2] 2.29
[122.2] [57.2] [58.1]
REF REF
2.41
[61.1]
3.06 [77.7]
0.81
2.56 [20.6]
[65.0] 1.94
[49.3]
1.60
[40.6]
2.75 4.46
[69.8] 0.25 [113.3]
[6.3]
1.32
[33.5]
4.95
[125.7] 0.63 [16.1]
3.06
[77.7] 0.81
2.38 [20.6]
[60.5]
Modular dove-tail
design for tool-less
snap together assembly
Test probe holes
600V
Plate
JM60030-2PR 1 $31.00 AC/DC 2 18-10 AWG (Cu) 18-10 AWG 20 [2.3] 0.25 [0.12]
JM60030-3PR 1 $46.75 3 0.40 [0.18]
JM60060-1CR 1 $18.75 1 3-2 AWG 50 [5.6] 0.20 [0.10]
Box lug
JM60060-2CR 1 $36.50 60 2 14-2 AWG (Cu) 6-4 AWG 45 [5.1] 0.35 [0.16] CVR-J-60060 CVRI-J-60060 1
8-2 AWG (Al) 8AWG 40 [4.5] $6.25 $7.25
JM60060-3CR 1 $49.00 3 14-10 AWG 35 [4.0] 0.55 [0.26]
¹ Open fuse indication requires 90V minimum and closed circuit to operate.
in [mm]
JM60030
JM60060
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
Description Specifications
For use with Edison JDL class J fuses Construction: T hermoplastic,
UL Flammability; 94V-0
Terminal type: Voltage Ratings: 600 Volts AC
• C = Box lug type
Ampere Ratings: 0.50 - 600 Amps
• CR = Box lug type, with retaining clip
Short-circuit current Rating: 200,000 RMS
• P = Pressure plate. Clip reinforcin
springs are standard on fuseblocks Symmetrical Amps
rated 100A and above.
Agency Approvals
• UL Listed, UL 512, Guide IZLT, File E14853
J60060-1C • CSA, certified, C22.2 No. 39, Class 6225-01,
File 47235
* Not UL
4.01
6.28"
C
L
CL [102]
[160
1.50
[38.1]
.75
61 Amp[119.4]
2.25
to 100 Amp [58] [49.4]
.94 1.58
[127]
.30 [38.1]
2] [19.1] [57.2] [40.1]
[7.62] [23.8]
[5.6]
3.14
[79.8]
1.50
1.75 1.5
101 Amp to 200 Amp
[38.1]
[44.5] [38.1]
Figure 4
3 3.1
8.31
[76.2] [78.7]
.75 [211.1] 3.15
2 [19.1] 7.00 [80]
[50.8] .5 .31 [177.8]
[12.7] [7.8]
3.06
[77.7] .75 [19.1] .344 [8.74]
c'bore 6.13 dia. hole through
[155.7] .750 [19.1]
6.13 1.69 dia. c'bore
.34 [8.6]
[155.7] dia. [42.9]
.750
Figure 5 Figure 6 [19.1]
3.5 7.50
[88.9] .75 [19.1] [191]
c'bore
7.5 .34 [8.6] .344 [8.7] .50
dia. 2.0 dia. hole through
[191] [12.7]
[50.8] .750 [19.1]
.5 dia. c'bore
[12.7]
Figure 10
1.00
Figure 9 Note: All dimensions shown in inches [mm]
[25.4]
E G
Dimensions H
CH30J in
Dimension CH60J in (mm)
(mm)
A 1.28 (32.5) 1.58 (40.0)
B 2.56 (65.0) 3.16 (80.0) D F
C 3.84 (97.5) 4.72 (120.0)
D 4.59 (116.6) 4.88 (124.0)
E 2.83 (71.8) 3.31 (84.1)
F 3.56 (90.4) 3.85 (97.9)
G 1.28 (32.5) 1.58 (40.0) 3 POLE CLASS J A
Modular Fuse Holder B
H 0.18 (4.44) 0.18 (4.44)
C
Part Number
(1 pc/pkg) solid and stranded*** fine stranded lb·in lb [kg] w/o w/ Pcs/
(Cu) [N·m] Indication Indication Pkg
JM60100-1CR-1 1 – 0.32 CVR-J-60100-M-1 CVRI-J-60100-M-1 1
$25.00 3-1 AWG 55 [6.2] [0.14] $6.75 $12.00
3-1/0 AWG; (2) Cu 6-4 AWG 6-4 AWG 50 [5.6]
JM60100-1CR-2 600 100 2 6-4 AWG; (2) Cu 8AWG 8AWG 45 [5.1] 0.64 CVR-J-60100-M-2 CVRI-J-60100-M-2 2
$50.00 8AWG ; (2) Cu 14-10 AWG – 40 [4.5] [0.28] $13.50 $24.00
JM60100-1CR-3 Cu 14-10 AWG; Al 12-10 AWG 0.96 CVR-J-60100-M-3 CVRI-J-60100-M-3
3 – 35 [4.0] 3
$75.50 [0.42] $20.25 $35.50
JM60200-1CR-1 1 0.82 CVR-J-60200-M-1 CVRI-J-60200-M-1 1
$105.00 [0.37] $8.25 $13.50
1AWG - 250MCM 1-3/0 AWG 375 [42]
JM60200-1CR-2 600 200 2 1.64 CVR-J-60200-M-2 CVRI-J-60200-M-2 2
$210.00 6-2 AWG; (2) Cu 6-2 AWG 6-2 AWG 275 [31] [0.74] $17.25 $27.50
JM60200-1CR-3 3 2.46 CVR-J-60200-M-3 CVRI-J-60200-M-3 3
$315.75 [1.11] $25.50 $41.00
JM60400-1CR-1 1 600MCM 500 [57] 2.16 CVR-J-60400-M-1 CVRI-J-60400-M-1 1
$188.25 500MCM 450 [51] [0.98] $15.00 $21.25
600 400 N/A
JM60400-1CR-3 (2) Cu 4-3/0 AWG 500 [57] 6.48 CVR-J-60400-M-3 CVRI-J-60400-M-3
3 (2) Al 4-3/0 AWG 300 [34] 3
$565.25 [2.94] $44.75 $63.50
JM60400-1MW22-1* 1 2.58 CVR-J-60400-M-1 CVRI-J-60400-M-1 1
$221.00 (2) 1AWG - 350MCM 375 [42] [1.17] $15.00 $21.25
600 400 NA
JM60400-1MW22-3* 3 (2) 6-2 AWG 275 [51] 7.74 CVR-J-60400-M-3 CVRI-J-60400-M-3 3
$636.50 [3.51] $44.75 $63.50
JM60600-1CR-1* 1 3.92 CVR-J-60600-1 CVRI-J-60600-1 1
$309.50 [1.78] $24.50 $30.50
600 600 (2) 4AWG - 500MCM N/A 450 [51]
JM60600-1CR-3* 3 11.76 CVR-J-60600-3 CVRI-J-60600-3 3
$927.75 [5.34] $77.00 $95.75
* Modular double box lug fuse block
** Covers sold separately. Blown fuse indication requires 90V minimum and closed circuit to operate.
*** Ratings are for copper and aluminum wire except where otherwise noted.
JM60100 Series
JM60200 Series
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
JM60400 Series
JM60600 Series
JM60400-1MW22-x
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
Agency Approvals
• Blocks - UL - UR recognized E14853 – IZLT2
• CSA - Certified 47235 – 6225-01
Class J Covers for Class J • Covers - UL - Listed UL E58836 – JDVS
Power Distribution Blocks Power Distribution Blocks • CE, RoHS, Reach Compliant
To obtain the most current agency approval information, see the Agency
Approval Checklist section on the specific part number's web page.
Part Number
(1 pc/pkg) Wire range Torque Wire range Torque lb [kg] w/o w/ Pcs/
(AWG) N·m [lb·in] (AWG) N·m [lb·in] Indication Indication Pkg
JM60100-1MW14-1 1
0.32 CVR-J-60100-M-1 CVRI-J-60100-M-1
1
$28.50 [0.15] $6.75 $12.00
1-1/0; 5.6 [50] (4) 14-4 Cu, 6-4; 4.0 [35]
JM60100-1MW14-2 100 2 (1) 14 - 1/0 6-4; 5.0 [45] 8-4 Al 8; 2.8 [25] 0.64 CVR-J-60100-M-2 CVRI-J-60100-M-2 2
$55.00 Cu/Al 8; 4.5 [40] 14-10; 2.3 [20]† [0.3] $13.50 $24.00
14-10; 4.0 [35] (8)** 14-10 Cu (2) 14-10; 3.4 [30]†
JM60100-1MW14-3 3
0.96 CVR-J-60100-M-3 CVRI-J-60100-M-3
3
$82.75 [0.45] $20.25 $35.50
Dimensions Connections
Block Size A B C D E F G H I J K L M øN øO Lineside (P) Loadside (Q)
in 2.0 4.0 6.0 5.5 5.5 2.8 2.2 6.0 2.8 0.9 2.0 0.4 1.1 0.4 0.5
100A 1 4
mm 51 102 153 139 139 72 55 152 72 22 51 10 29 9 13
in 2.6 5.3 8.0 6.8 6.8 3.8 3.0 7.3 3.8 1.4 2.6 0.3 1.3 0.4 0.7
200A 1 6
mm 67 134 203 172 172 97 75 186 97 35 34 8 32 9 19
in 3.5 7.0 10.6 8.0 8.0 4.8 4.1 8.7 4.8 2.0 3.5 0.3 1.6 0.4 0.7
400A 2 (1)* 6
mm 88 177 268 202 202 121 105 220 121 50 88 8 41 9 19
*JM60400-1MW16-X
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
Agency Approvals
Specifications • Blocks - UL - Listed cULus E14853 – IZLT & IZLT7
• CSA - Certified 47235 – 6225-01
Materials:
• Covers - UL - Listed UL E58836 – JDVS
Base – thermoplastic
• CE, RoHS, Reach Compliant
Box lug terminals – tin-plated aluminum
To obtain the most current agency approval information, see the Agency
SCCR: 200kA sym RMS Approval Checklist section on the specific part number's web page.
Flammability rating:
Blocks – UL 94V0, self-extinguishing
Covers – UL 94HB, self-extinguishing
Operating and storage temp range:
Blocks – -40° to 120°C [-40° to 248°F]
Covers – indicating -20° to 90°C [-4° to 194°F]
non-indicating -40° to 120°C [-40° to 248°F]
Part Number
(1 pc/pkg) solid and stranded** fine stranded lb·in [N·m] lb [kg] w/o w/ Pcs/
(Cu) Indication Indication Pkg
RM25100-1CR-1 1 0.86 [0.39] CVR-RH-25100-1 CVRI-RH-25100-1 1
$22.25 – 3-1 AWG 55 [6.2] $7.75 $13.00
3-1/0 AWG; (2) Cu 6-4 AWG 6-4 AWG 50 [5.6]
RM25100-1CR-2 250 100 2 6-4 AWG; (2) Cu 8AWG 8AWG 45 [5.1] 1.72 [0.78] CVR-RH-25100-2 CVRI-RH-25100-2 2
$44.25 8AWG ; (2) Cu 14-10 AWG – 40 [4.5] $16.00 $25.50
RM25100-1CR-3 3 Cu 14-10 AWG; Al 12-10 AWG – 35 [4.0] 2.58 [1.17] CVR-RH-25100-3 CVRI-RH-25100-3 3
$66.50 $24.00 $38.00
RM25200-1CR-1 1 0.88 [0.4] CVR-RH-25200-1 CVRI-RH-25200-1 1
$76.00 $10.50 $17.25
1AWG - 250MCM 1-3/0 AWG 375 [42]
RM25200-1CR-2 250 200 2 1.76 [0.8] CVR-RH-25200-2 CVRI-RH-25200-2 2
$145.50 6-2 AWG; (2) Cu 6-2 AWG 6-2 AWG 275 [31] $21.50 $33.50
RM25200-1CR-3 3 2.64 [1.2] CVR-RH-25200-3 CVRI-RH-25200-3 3
$227.25 $33.25 $50.00
RM25400-1CR-1 1 600MCM 500 [57] 2.24 [1.02] CVR-RH-25400-1 CVRI-RH-25400-1 1
$245.00 500MCM - 4AWG 450 [51] $17.50 $24.00
250 400 N/A
RM25400-1CR-3 (2) Cu 4-3/0 AWG 500 [57] CVR-RH-25400-3 CVRI-RH-25400-3
3 (2) Al 4-3/0 AWG 300 [34] 6.72 [3.06] 3
$734.25 $52.00 $73.00
RM25600-1CR-1 1 4.04 [1.83] CVR-RH-25600-1 CVRI-RH-25600-1 1
$319.75 $31.50 $39.50
250 600 (2) 4AWG - 500 MCM N/A 450 [51]
RM25600-1CR-3 3 12.12 [5.49] CVR-RH-25600-3 CVRI-RH-25600-3 3
$921.50 $95.00 $115.00
RM60100-1CR-1 1 0.34 [0.16] CVR-RH-60100-1 CVRI-RH-60100-1 1
$28.00 – 3-1 AWG 55 [6.2] $9.50 $16.25
3-1/0 AWG; (2) Cu 6-4 AWG 6-4 AWG 50 [5.6]
RM60100-1CR-2 600 100 2 6-4 AWG; (2) Cu 8AWG 8AWG 45 [5.1] 0.68 [0.32] CVR-RH-60100-2 CVRI-RH-60100-2 2
$56.25 8AWG; (2) Cu 14-10 AWG – 40 [4.5] $19.75 $32.25
RM60100-1CR-3 3 Cu 14-10 AWG; Al 12-10 AWG – 35 [4.0] 1.02 [0.48] CVR-RH-60100-3 CVRI-RH-60100-3 3
$84.25 $29.00 $47.75
RM60200-1CR-1 1 0.92 [0.42] CVR-RH-60200-1 CVRI-RH-60200-1 1
$71.75 $13.00 $19.75
1AWG - 250MCM 1-3/0 AWG 375 [42]
RM60200-1CR-2 600 200 2 1.84 [0.84] CVR-RH-60200-2 CVRI-RH-60200-2 2
$143.00 6-2 AWG; (2) Cu 6-2 AWG 6-2 AWG 275 [31] $24.50 $38.00
RM60200-1CR-3 3 5.52 [2.52] CVR-RH-60200-3 CVRI-RH-60200-3 3
$214.75 $38.50 $60.25
RM60400-1CR-1 1 600MCM 500 [57] 2.32 [1.05] CVR-RH-60400-1 CVRI-RH-60400-1 1
$199.25 4AWG - 500MCM 450 [51] $22.00 $31.25
600 400 N/A
RM60400-1CR-3 (2) Cu 4-3/0 AWG 500 [57] CVR-RH-60400-3 CVRI-RH-60400-3
3 (2) Al 4-3/0 AWG 300 [34] 6.96 [3.15] 3
$598.00 $69.75 $91.00
RM60600-1CR-1 1 4.16 [1.88] CVR-RH-60600-1 CVRI-RH-60600-1 1
$319.75 $40.50 $47.00
600 600 (2) 4AWG - 500MCM N/A 450 [51]
RM60600-1CR-3 CVR-RH-60600-3 CVRI-RH-60600-3
3 12.48 [5.64] $117.00 $142.00 3
$922.00
* Covers sold separately. Blown fuse indication requires 90V minimum and closed circuit to operate.
** Ratings are for copper and aluminum wire except where otherwise noted.
RM25100 Series
RM25200 Series
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
RM25400 Series
RM25600 Series
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
RM60100 Series
RM60200 Series
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
RM60400 Series
RM60600 Series
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
Tin-plated bimetallic
copper fuse clips
Patented lockout/tagout
DIN rail and panel mount
Modular design
for tool-less
snap together assembly Compact footprint
Pressure Plate (with Quick Connect**) Modular Ferrule Fuse Blocks for Midget Class and CC Fuses
Wire Range¹ Torque Wt. Covers* (Sold Separately)
Poles
Class
Pc/
Part Number pkg Price Volts Amps solid and
stranded
fine
stranded lb·in [N·m] lb [kg] w/o
Indication
w/
Indication³
Pc/
pkg
BMM603-1PQ 15 $66.00 1 0.05 [0.04]
BMM603-2PQ
Midget
BCM Series
BMM Series
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
in [mm]
BCCMM603-3PQ
Please see our website www.AutomationDirect.com for complete engineering drawings. Dimensions are approximate. Not for construction purposes.
Agency Approvals
• UL listed to 512 , Guide IZLT, File 14853
• CSA C22.2 No. 39 Class 6225-01, File LR47235
• CE Compliant
Description Specifications
These panel-mount fuse blocks are for use Terminal type: Pressure plate with quick connect
with any 13/32” x 1-1/2” Class M Fuses (Edi- terminal
son MCL, MEQ, MEN and MOL). Base: Thermoplastic
Clips: Bright tin-plated bronze
UL Flammability: 94V-0
Ratings: 600 VAC, 30 Amps
Agency Approvals
• UL Recognized to 512, Guide IZLT2,
File E14853
• CSA C22.2, No.39, Class 6225-01, File 47235
0.200" + 0.003"
(5.08mm + 0.08mm)
Three Pole
BC6033PQ
3 POLE
0.425"
(10.80mm)
1.530"
2.375" + 0.015" (38.86mm)
(60.33mm + 0.38mm)
0.200" + 0.003"
(5.08mm + 0.08mm)
Buss ®
BUSSMANN
COOPER INDUSTRIES
1.210" + 0.015" 30A 600V
ST. LOUIS, MO 63178
MADE IN U.S.A.
(30.73mm + 0.38mm) CLASS CC 75 C WIRE
FUSES ONLY 200,000A RMS SYM
WITHSTAND RATING
CU ONLY
10 AWG 20 LBJN. R
Dimensional Data
0.77"
(19.4mm)
M Class 1.53"
(38.9mm)
Dimensions 1.22"
(31.0mm)
0.36"
(9.1mm)
0.42"
(10.7mm)
0.42"
(10.7mm)
inches(mm)
3"
(76.2mm)
1.5"
(38.1mm)
Application
• EHM: Edison MCL, MOL, MEQ, MEN, or
midget fuses
• EHCC: Edison HCLR, HCTR, EDCC fuses,
or class CC fuses
* To add additional poles, see multi-pole connection kit JV-L in accessories. One JV-L kit is sufficient to gang up to 4 poles.
• UL Recognized, CSA
•• UL Listed, CSA
EHCC3DU EHCC3DIU
3
EHCC3DU-4 EHCC3DIU-4
Agency Approvals/Standards
• UL508, File E195399
• CE
• RoHS
• Reach
EB1P100M9 600VAC
100A Ships w/2 Endcaps 9 5.38 1 $12.75
Single-phase (power feed
1000VDC
EB1P100M12 from end) 12 7.94 $15.75
Comb-Bus Bars
Typical Single-Phase Dimensional Data
mm [inches]
EB3P100M12 EPWR35MM
EB3P100M12
EECAPMP Ships w/2 Endcaps
Modular
Fuse Holders
EFSCVR
EPWR50MM
JV-L
Comb-Bus Accessories
Dimensions
mm [inches]
EPWR1PLP
EPWR1PLP-1
EECAP1P
EECAP1P-10
EECAPMP
EECAPMP-10
EPWR50MM
EPWR50MM-1
Comb-Bus Accessories
Dimensions
mm [inches]
EPWR35MM
EPWR35MM-1
EFSCVR
EFSCVR-2
Accessories
Accessories
Part Number Description Pcs/Pkg Price
Fuse puller for fuse dia. 13/32” - 13/16”. Fuse type: 0-60A, 250V;
FP-2 0-30A, 600V
1 $16.75
JV-L
JV-L
Ordering Information
Part Pcs/ Price Part Pcs/ Price Part Pcs/ Price Part Pcs/ Price
Number Pkg Number Pkg Number Pkg Number Pkg
DN-F6 25 $93.00 DN-F10 50 $149.00
Gray Terminal Block – –
DN-F6MN 7 $20.00 DN-F10MN 10 $22.75
12-24 VAC/DC* DN-F6L24 10 $54.00 DN-F10L24 10 $53.00
110 VAC/DC* – DN-F6L110 10 $54.00 – DN-F10L110 10 $53.00
220 VAC/DC* DN-F6L220 10 $54.00 DN-F10L220 10 $53.00
Technical Specifications
Stripping Length 12mm [0.47 in] 12mm [0.47 in] 10mm [0.39 in] 10mm [0.39 in]
Tightening Torque 2.0 N·m [17.7 lb·in] 2.0 N·m [17.7 lb·in] 0.6 N·m [5.3 lb·in] 0.6 N·m [5.3 lb·in]
Density 100/m [30 pcs/ft] 100/m [30 pcs/ft] 100/m [30 pcs/ft] 100/m [30 pcs/ft]
UL Approval** 600V 30A 20-6 AWG 600V 30A 20-6 AWG 300V 15A 24-10 AWG 300V 15A 24-10 AWG
CSA Approval 600V 30A 18-6 AWG 600V 30A 18-6 AWG 300V 8A 18-12 AWG 300V 8A 18-12 AWG
VDE Approval 750V 8A – 750V 8A – 500V 8A 4mm² 500V 8A 4mm²
Fuse Size (not supplied) 1 1/4” X 1/4” 1 1/4” X 1/4” 5x20mm-5x25mm 5x20mm-5x25mm
Indicator Type Non-indicating LED blown fuse indicator Non-indicating LED blown fuse indicator
Operating Temperature Ambient air temperature: -20°C to 85°C [-4°F to 185°F] / Relative humidity: 50% max at 40°C [104°F]; 90% max at 20°C [68°F]
SCCR Rating 10kA per Table SB4.1, 2009, UL 508A, Maximum short circuit current rating for unmarked components
CE Conformity CE (EN 60947-1 / 60947-7-3)
Agency File # UL E179129 / LR84816
Note: To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number's web page.
Accessories
End Covers Included Included Included Included
DN-R35S1
7.5 mm 10 $28.00 DN-R35S1 10 $28.00 DN-R35S1 10 $28.00 DN-R35S1 10 $28.00
35mm high
DN-R35S1-2 2 $9.00 DN-R35S1-2 2 $9.00 DN-R35S1-2 2 $9.00 DN-R35S1-2 2 $9.00
DIN Rail 15mmDN-R35HS1 10 $49.50 DN-R35HS1 10 $49.50 DN-R35HS1 10 $49.50 DN-R35HS1 10 $49.50
high
DN-R35HS1-2 2 $12.00 DN-R35HS1-2 2 $12.00 DN-R35HS1-2 2 $12.00 DN-R35HS1-2 2 $12.00
DN-EB35 50 $39.50 DN-EB35 50 $39.50 DN-EB35 50 $39.50 DN-EB35 50 $39.50
DN-EB35MN 20 $18.00 DN-EB35MN 20 $18.00 DN-EB35MN 20 $18.00 DN-EB35MN 20 $18.00
DN-EB35-A 50 $28.50 DN-EB35-A 50 $28.50 DN-EB35-A 50 $28.50 DN-EB35-A 50 $28.50
End Brackets
DN-EB35-A-10 10 $7.50 DN-EB35-A-10 10 $7.50 DN-EB35-A-10 10 $7.50 DN-EB35-A-10 10 $7.50
DN-QEB35 50 $25.50 DN-QEB35 50 $25.50 DN-QEB35 50 $25.50 DN-QEB35 50 $25.50
DN-QEB35-10 10 $7.50 DN-QEB35-10 10 $7.50 DN-QEB35-10 10 $7.50 DN-QEB35-10 10 $7.50
Angled Support Bracket DN-ASB1 50 $49.50 DN-ASB1 50 $49.50 DN-ASB1 50 $49.50 DN-ASB1 50 $49.50
Marking Tags DN-L*** or 500/ various
DN-L*** or 500/ various
DN-L*** or 500/ DN-L*** or 500/
100 various DN-LT**** various
DN-LT**** 100 DN-LT**** 100 DN-LT**** 100
*Working voltage **For copper wire only ***On lever arm ****On terminal body
Note: DN-F6 series fuse holders will accommodate the following AutomationDirect fuses: ABC, AGC, MDA and MDL Series.
DN-F10 series fuse holders will accommodate the following AutomationDirect fuses: GMA, GMC, S500, and S506 Series.
For more information on accessories, see the DINnectors Accessories section of this chapter.
44 mm 44 mm
[1.73 in] [1.73 in]
66 mm 66 mm
[2.6 in] [2.6 in]
10 mm 10 mm
[0.39 in] [0.39 in]