M2CA Device
M2CA Device
M2CA Device
Typical Applications
• Centralized monitoring and control of motors, pumps or [3] POWER INPUT
heaters by DCS AC Power
• Monitoring power line and power supply current M: 85 – 264 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
23 (.91) (Select ‘/N’ for ‘Standards & Approvals’ code.)
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
(90 – 264 V for UL)
Model
76 DC Power
(2.99)
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
ZERO
R2: 11 – 27 V DC
SPAN
124
(4.88) (Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
mm (inch) (Select ‘/N’ for ‘Standards & Approvals’ code.)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
MODEL: M2CA–[1][2]-[3][4] (110 V ±10 % for UL)
https://www.m-system.co.jp/
MODEL: M2CA
GENERAL SPECIFICATIONS Insulation resistance: ≥ 100 MΩ with 500 V DC
Construction: Plug-in Dielectric strength: 2000 V AC @1 minute (input to output
Connection: M3 screw terminals (torque 0.8 N·m) to power to ground)
Screw terminal: Chromated steel (standard) or stainless
steel STANDARDS & APPROVALS
Housing material: Flame-resistant resin (black) EU conformity:
Isolation: Input to output to power EMC Directive
Input waveform EMI EN 61000-6-4
Average sensing: Sine wave EMS EN 61000-6-2
Overrange output: 0 to 120 % at 1 – 5 V Low Voltage Directive
Zero adjustment: -5 to +5 % (front) EN 61010-1
Span adjustment: 95 to 105 % (front) Installation Category II
Pollution Degree 2
INPUT SPECIFICATIONS Input or output to power: Reinforced insulation (300 V)
Frequency: 50 or 60 Hz Input to output: Basic insulation (300 V)
Input burden: RoHS Directive
≤ 0.1 VA (input 0 – 1 A) UK conformity (UKCA):
≤ 0.5 VA (input 0 – 5 A) The UK legislations and designated standards are
Overload capacity: 500 % of rating for 5 sec., 120 % equivalent to the applicable EU directives.
continuous (Refer to M-System’s website for more information about
Operational range: 0 – 120 % of rating the legislations and designated standards.)
Approval:
UL/C-UL nonincendive Class I, Division 2,
OUTPUT SPECIFICATIONS Groups A, B, C, and D
■ DC Current: 0 – 20 mA DC (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)
Minimum span: 1 mA UL/C-UL general safety requirements
Offset: Max. 1.5 times span (UL 61010-1, CAN/CSA-C22.2 No.61010-1)
Load resistance: Output drive 15 V max.
■ DC Voltage: 0 – 12 V DC
Minimum span: 5 mV
Offset: Max. 1.5 times span
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V
INSTALLATION
Power Consumption
•AC:
Approx. 3 VA at 100 V
Approx. 4 VA at 200 V
Approx. 5 VA at 264 V
•DC: Approx. 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 150 g (0.33 lb)
https://www.m-system.co.jp/
MODEL: M2CA
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
approx. 200 (7.9) CT PROTECTOR
(total of both sides) (model: CTM2) 6 (.23)
28 (1.10)
DIN RAIL
35mm wide 4 1
8 5
2–4.2x5
(.17x.20)
70.5 (2.78)
59 (2.32)
72 (2.83)
MTG HOLE
6 (.24) deep
8–M3 12 9
SCREW 14 13
4 (.16)
114 (4.49) [4 (.16)] 23 (.91)
SOURCE
Z S
INPUT
K k TRANSFORMER Average Output
1 Operation Driver
9 +
CT OUTPUT
4 12 –
L l
5 13 U(+)
LOAD POWER
8 14 V(–)
https://www.m-system.co.jp/