S-Band Limiter

DESCRIPTION GENERAL
The B3LT1018 is a 30kW solid state S-band high Outline……………………………………………..B3LT1018_SHT3
power limiter with an integral filter for protection Overall dimensions.............. 122 x 105 x 55.4 mm nom
against magnetron-generated spurious signals in Waveguide size .................................... WG10 (WR284)
marine radar systems. A triggered STC generator Connectors:
circuit is provided. waveguide ..................................................... special
STC circuit.................................. Lumburg 2.5MBC 3
CHARACTERISTICS (at 20°C ambient) Pin 1……………………………………………………………Supply
see notes 1 and 6 Pin2……………………………………………………………Trigger
Pin3………………………………………………………………Earth
Frequency………………………………… 3.02 to 3.08 GHz
Return loss……………………………….. 18 dB min Mounting position................................................... any
Insertion loss……………………………. 1 dB max Net weight ................................................. 1 kg approx.
Total peak leakage (PO 30 kW)…. 100 mW max
Recovery to -3 dB (PO 10 kW)…… 1 µs max NOTES
STC maximum (see note 2)………. 20 dB
1. High power tests measured at 3.05 GHz, tp 0.1, du
STC response: 0.001, STC tests measured at 3.05 GHz, VS +12 V, VP
at 3.0µs (see note 3)………………… 10 ± 1.5 dB +3.5 V, tP 2 µs.
at 11µs 1.5 dB max 2. Attenuation level that the maximum attenuation from the
Clutter saturation (see note 4) 5 dB max STC generator circuit can be set to by variable resistor
STC bias voltage (see note 5) 4.25 V min RV1.
3. Measured from the start of the STC ramp with maximum
MAXIMUM AND MINIMUM RATINGS attenuation of 20 dB.
4. Change in the maximum attenuation of the STC curve
MIN MAX due to 10 mW of incident power.

Transmitter power: 5. Voltage at the cathode of D1A when the attenuation is


20 dB. Design parameter only.
peak .............................................. - 30 kW
mean ............................................. - 30 W 6. Maximum and minimum characteristic values may be
exceeded at the temperature extremes. Contact e2v for
Pulse duration .................................... - 2.0 µs details.
Duty ratio ........................................... - 0.001
7. The components on the STC generator circuit are
STC circuit supply .......................... 11.5 12.5 V exposed and are static sensitive. Correct procedures for
STC trigger pulse…………………………… 3.5 5.5 V handling of such components are to be adhered to.
Ambient temperature: 8. The STC circuit cable must be clamped on installation to
operating ................................. −40 +90 °C minimise damage resulting from excessive flexing. The
storage ..................................... −50 +90 °C limiter must be mounted so that the EMC effects are
contained.

Whilst e2v technologies has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use
thereof and also reserves the right to change the specification of goods without notice. e2v technologies accepts no liability beyond the set out in its standard
conditions of sale in respect of infringement of third party patents arising from the use of tubes or other devices in accordance with information contained herein.
e2v technologies (uk) limited, Waterhouse Lane, Chelmsford, Essex CM1 2QU United Kingdom Holding Company: e2v technologies plc
Telephone: +44 (0)1245 493493 Facsimile: +44 (0)1245 492492
Contact e2v by e-mail: enquiries@e2v.com or visit www.e2v.com for global sales and operations centres.
© e2v technologies (uk) limited 2016 M210286A Version 3, June 2016
Template: DF764388A-11 123197

You might also like