9106B
– 24 VDC supply via power rail or connectors
– Active and passive mA input
– Active or passive output via the same two terminals
– Splitter function - 1 in and 2 out
– SIL3 Full Assessment and certified acc. to IEC 61508
Application
Applications
• 9106B is a 1- or 2-channel isolated 1:1 repeater barrier for
intrinsic safety applications.
• The device supplies 2-wire SMART transmitters and can also
be used for 2-wire SMART current sources. HART & BRAIN
protocols are supported and are transferred bi-directionally.
• 9106B can be mounted in the safe area or in zone 2 / Cl. 1,
div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21,
22 including mining / Class I/II/III, Div. 1, Gr. A-G.
• For duplication/migration purposes, the outputs can be sent to
two different DCS/PLC/HMI or any monitoring system.
• In safety applications (SIL loops), the 9106BxBx can be used
as a splitter with the following output configuration:· When
using 9106BxBx in a SIL2 safety function, channel 1 is used
for the safety loop. Channel 2 can be used for any non-safety
device.· For higher safety purposes (SIL 3), 9106BxBx can be
used as a splitter for SIL 3 loops. Channel 1 and 2 are
then connected to the same safety PLC, where channel 2 is
used as a redundant diagnostic channel. (for more
information, consult the FMEDA Report and the Safety
Manual).
Advanced features
• The PR 45xx detachable display and the green and red front
LEDs indicate operation status for each channel.
• Monitoring of error events and cable breakage on input via
the individual status relay and/or a collective electronic signal
via the power rail.
• Suitable for the use in systems up to Performance Level “d”
according to ISO-13849.
Technical characteristics
• High galvanic isolation of 2.6 kVAC.
• Fast response time <5 ms
• High accuracy better than 0.1%.
• 2-wire transmitter supply >16 V.
Mounting
• The devices can be mounted vertically or horizontally without
distance between neighboring units.
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions Input voltage drop, supplied
unit................................................................. < 4 V @ 23 mA
Operating temperature................................... -20°C to +60°C Input voltage drop, non-supplied
Storage temperature...................................... -20°C to +85°C unit................................................................. < 6 V @ 23 mA
Calibration temperature................................. 20...28°C
Relative humidity............................................ < 95% RH (non-cond.)
Protection degree........................................... IP20 Output specifications
Installation in.................................................. Pollution degree 2 & meas. / Current output
overvoltage cat. II Signal range................................................... 3.5...23 mA
Load (@ current output)................................. ≤ 600 Ω
Mechanical specifications Load stability.................................................. ≤ 0.01% of span / 100 Ω
Dimensions (HxWxD)..................................... 109 x 23.5 x 104 mm Current limit.................................................... ≤ 28 mA
Dimensions (HxWxD) w/ 4501/451x.............. 109 x 23.5 x 116 / 131 mm
Weight approx................................................ 250 g Passive 2-wire mA output
Weight incl. 4501 / 451x (approx.)................. 265 g / 280 g Effect of external 2-wire
supply voltage variation................................. < 0.005% of span / V
DIN rail type................................................... DIN EN 60715/35 mm
Max. external 2-wire supply........................... 26 VDC
Wire size........................................................ 0.13...2.08 mm2 AWG 26...14
stranded wire Status relay
Screw terminal torque.................................... 0.5 Nm Relay function................................................ N.C.
Vibration......................................................... IEC 60068-2-6 Programmable low setpoint........................... 0...29.9 mA
2...13.2 Hz...................................................... ±1 mm Programmable high setpoint.......................... 0...29.9 mA
13.2...100 Hz.................................................. ±0.7 g Hysteresis for setpoints.................................. 0.1 mA
Max. voltage................................................... 125 VAC / 110 VDC
Common specifications Max. current................................................... 0.5 AAC / 0.3 ADC
Supply Max. voltage - hazardous installation............. 32 VDC / 32 VAC
Supply voltage............................................... 19.2...31.2 VDC Max. current - hazardous installation............. 1 ADC / 0.5 AAC
Fuse............................................................... 1.25 A SB / 250 VAC
of span........................................................... = normal measurement range
Max. required power...................................... ≤ 1.1 W / ≤ 1.9 W (1 ch. / 2 4...20 mA
ch.)
Max. power dissipation, 1
/ 2 ch.............................................................. ≤ 0.8 W / ≤ 1.2 W Observed authority requirements
EMC............................................................... 2014/30/EU
Isolation voltage LVD................................................................ 2014/35/EU
Test /working: Input to any............................. 2.6 kVAC / 300 VAC ATEX.............................................................. 2014/34/EU
reinforced isolation
RoHS.............................................................. 2011/65/EU
Analog output to supply................................. 2.6 kVAC / 300 VAC
reinforced isolation EAC................................................................ TR-CU 020/2011
Status relay to supply..................................... 1.5 kVAC / 150 VAC EAC Ex........................................................... TR-CU 012/2011
reinforced isolation
Approvals
Response time ATEX.............................................................. DEKRA 11ATEX0244 X
Response time (0...90%, 100...10%)............. < 5 ms IECEx............................................................. DEK 11.0084X
Programming................................................. PR 4500 communication c FM us.......................................................... FM16US0465X /
interfaces FM16CA0213X
Signal dynamics, input................................... Analog signal chain INMETRO....................................................... DEKRA 16.0001 X
Signal dynamics, output................................. Analog signal chain c UL us, UL 61010-1..................................... E314307
SMART bi-directional communication c UL us, UL 913............................................. E233311 (only 9106xxx-U9)
frequency range............................................. 0.5...7.5 kHz EAC Ex........................................................... RU C-DK.HA65.B.00355/19
Signal / noise ratio......................................... > 60 dB DNV-GL Marine............................................. TAA00000JD
Accuracy........................................................ Better than 0.1% of sel. range ClassNK......................................................... TA18527M
mA, absolute accuracy................................... ≤ ±16 μA SIL.................................................................. SIL 2 / SIL 3 certified & fully
mA, temperature coefficient........................... ≤ ±1.6 μA / °C assessed acc. to IEC 61508
Effect of supply voltage change
on output (nom. 24 VDC)............................... < ±10 μA
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE21, A criterion, burst.................................. < ±1% of span
Input specifications
Current input
Measurement range....................................... 3.5...23 mA
2-wire transmitter supply
9106B-113020