MODEL Electro-proportional relief valve - high pressure setting with no command

RPEI SERIES 1 / CAPACITY: 95 L/min. / CAVITY: T-13A

sunhydraulics.com/model/RPEI

This 2-port, pilot-operated relief cartridge is an electro-proportionally controlled, normally-closed pressure regulating
valve. The valve is spring biased closed to its highest setting (customer specified). Increasing current to the coil will
proportionally decrease the pressure setting. When the pressure at port 1 (inlet) is sufficient to overcome the spring
force minus the solenoid force, as determined by the analog input signal, the poppet lifts and allows flow from port
1 to port 2 (outlet).

TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.

Cavity T-13A
Series 1
Capacity 95 L/min.
Factory Pressure Settings Established at 15 L/min.
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 30 cc/min.@70 bar
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Adjustment Screw Internal Hex Size 3,2 mm
Locknut Hex Size 11,1 mm
Locknut Torque 5 - 6 Nm
U.S. Patent # 10,775,812
Seal kit - Cartridge Buna: 990010007
Seal kit - Cartridge Viton: 990010006
Seal and nut kit - Coil Viton: 990740006
Model Weight 0.24 kg.

PROPORTIONAL PERFORMANCE DATA

Hysteresis (with dither) A-Range: 9%, W-Range: 10%


Linearity (with dither) A-Range: 3%, W-Range 5%
Repeatability (with dither) 3%
Recommended dither frequency 110 Hz
Deadband, nominal (as a percentage of input) 35%

NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.

c 2021 Sun Hydraulics 1 of 4


CONFIGURATION OPTIONS Model Code Example: RPEILAN
CONTROL (L) ADJUSTMENT RANGE (A) SEAL MATERIAL (N) COIL *
L Standard Screw Adjustment A 1500 - 3000 psi (105 - 210 bar), 3000 N Buna-N No coil
psi (210 bar) Standard Setting V Viton * Additional coil options are available
W 3000 - 5000 psi (210 - 350 bar), 5000
psi (350 bar) Standard Setting

TECHNICAL FEATURES
The setting represents the maximum relief pressure which the valve will default to with no command. As the command increases, the relief setting will decrease.
See performance curves for selected pressure range.
Varying the analog input signal to the proportional solenoid provides a step-less control of pressure.
Damped construction provides stable operation over a wide range of operating conditions.
For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
This cartridge utilizes 740 Series low-power and high-power coils, and 747 Series hazardous location coils.
All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
This valve is fully compatible with the XMD Expandable Mobile Drivers from Sun.
The preferred mounting configuration is horizontal or vertically with the coil down. The valve can be mounted coil up if it is installed below reservoir oil level to
prevent air accumulation in the solenoid tube. Do not actuate the valve manually or electrically when the valve is not installed.
Coils can be mounted on the tube in either direction.