3D View: SEVEN Fences

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Option 2

8m

5m

KEY PLAN

NOTES :
1- ALL DIMENSIONS AND AXES SHOULD BE READ IN
CONJUNCTION WITH ARCHITECTURAL DRAWINGS
BEFORE CONSTRUCTION.
2 - ALL DIMENSION AND LEVELS ARE IN MMS
3 - THE CUBIC STRENGTH OF R. CONCRETE NOT
LESS THAN 250 Kg/cm2
4 - GRADE OF REINFORCEMENT STEEL FY=420 MPA
5 -THE STEEL GRADE IS A37
9 - BOLTS AND ANCHOR BOLTS OF GRADE A490
7 - MIN SIZE OF WELD = 2 MM
10 - WELD USING IS EX70
11 - ALL WELDING PROCESSING MUST BE IN
WORKSHOP AND MUST BE CHECKED BEFORE
TRANSPORT TO FIELD
12 - USE BOLT CONNECTION IN FIELD AND ALL
MUST BE CHECKED BY CORRECT TORQUE
13 - USE CONNECTIONS OF EXPANSION JOINTS
EVERY 40 M

DESIGN LOADS
DEAD LOAD WIND LOAD
OWN WEIGHT OF STEEL WIND VELOCITY = 50 M/SEC
COVER = 15 KG/M2 TEMPERATURE
E.M = 5 KG/M2 + & - 48
LIVE LOAD
LIVE LOAD = 80 KG (CONS.)

SYMBOLS :

P.T PRETENSION BOLTS TYPE


B.T BEARING BOLTS TYPE
F.W FILET WELD
PL PLATE
C.F.S COLD FORMED SECTION
L ANGLE
S.H.S SQUARE HOLLOW SECTION
R.H.S RECTANGULAR HOLLOW SECTION

REFERENCE DRAWINGS
S.# DRAWING NO.

COORDINATION
DESIGN\PROJECT MANAGER ARCHITECT STRUCTURAL

CIVIL ELECTRICAL MECHANICAL

REVISIONS

00 26-8-2023 ISSUE FOR TEMPORARY FENCE TYPE 1 I.E

REV DATE DESCRIPTION DRAWN CHECKED APPROVED


CLIENT:
SAUDI ENTERTAIMENT
VENTURES
PMC:

WSP MIDDLE EAST

3D VIEW PROJECT:

SEVEN Fences
CONSULTANT:

dar al-handash
shair and partners

CONTRACTOR:

DRAWING TITLE:
TYPICAL TEMPORARY FENCE TYPE 3 H=2.4m
STRUCTURAL STEEL WORKS
3D
SCALE: SHEET SIZE: DATE:
N.T.S A1
DRAWN: CHECKED: ENGINEER: APPROVED:
ISLAM EZZ
DRAWING NUMBER: 05 REV.

00

ACONEX REF: DATE: 1-10-2023