Screenshot 2023-09-09 at 1.59.01 PM
Screenshot 2023-09-09 at 1.59.01 PM
Screenshot 2023-09-09 at 1.59.01 PM
LOCATION
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL -
ASHANTI REGION
CLIENT
Mr. ABDUL KADIR ISAHAK
DATE
SEPTEMBER 2022
NOTES.
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
A B C D E F G H TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.
8480
1200 950 900 2280 900 1050 1200 Recommended by
1b 1b
Approved by
3050
3050
Approved by
1830
Fill
1 1
1350
800
800
10000
Signed by
3800
3800
3450
3450
Fill
Fill
Fill
5700
3 3
1350
1350
Fill
900
Project
4 4
Fill
2250
Fill
1350
5 5 Client
Checked By
WeBuildGHANA
0240020446 Drawing No.
Date
SEPTEMBER 2022
FOUNDATION PLAN
NOTES.
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
A B C D E F G H TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.
8480
1200 950 900 2280 900 1050 1200 Recommended by
1b 1b
Approved by
3050
3050
Approved by
2430
Porch
1800
1 1
800
800
10000
Signed by
4100
4100
Bedroom
Bedroom
3450
3450
w4
w4
6000
D2 D2
3 D1 3
1350
1350
1200
D2
washroom Nook
w1
Project
Kitchen
4 4
2550
w2
1350
washroom D1
w1
5 w4
D2
5 Client
Checked By
WeBuildGHANA
0240020446 Drawing No.
Date
SEPTEMBER 2022
1b 3530 4650
1b
w5
1650
1650
washroom Approved by
1500
2900
1a 1a
w5
D1
Lobby
1400
Laundry
w5
2050
w2
1 1
800
800
D2
3000 Granted by
2 DD
2
K. Store
2200
10000
10000
Signed by
3450
3450
Living Area
w4
6075
6000
Balcony
3 3
Kitchen
4450
1350
w2
1350
D2
Dining Area
Project
4 4 A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
1350
1350
5180 3000
1000
5 w4 w2
5 Client
Checked By
C1 WeBuildGHANA
0240020446 Drawing No.
Date
SEPTEMBER 2022
1b 5180
1b
w5
1650
1650
Approved by
1800
Master
washroom
1a 1a
w5
D1
Approved by
1400
1400
walk in
w5
D2
Lobby
closet
1750
1 1
800
800
Granted by
2 DD
2
D2
10000
10000
Signed by
3450
3450
4850
Bedroom
w4
w4
w4
Master
Balcony
4725
Bedroom
6000
3 D2 3
1350
1350
D2
1000
Project
4 washroom
D1
closet 4 A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
1800
1350
1350
5 w4 w1
5 Client
Checked By
C1 WeBuildGHANA
0240020446 Drawing No.
Date
SEPTEMBER 2022
Signed by
10000
10000
10350
150mm concrete slab
6225
3 fall 3
Project
4 600 4 A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION
5 5
100
Client
A B C D D1 E F G H Scale 1:100
C1 Drawn By : Checked By
WeBuildGHANA
0240020446 Drawing No.
Date
SEPTEMBER 2022
ROOF PLAN
Aluminum Roofing Sheet
50 x 50mmCeiling members @ 900mm
NOTES.
50 x 50mm Hangers @ 1050 c/c
50 x 150mm Rafters @ 1200 c/c THIS IS AN AUTO CAD GENERATED
50 x 75mm Purlins @ 1050 c/c DRAWING. ALL DIMENSION AND LEVELS
A 1b 100mm thickness Parapet cap TO BE CHECKED VERIFIED ON SITE BY
1500mm High Parapet wall THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.
Recommended by
3000
washroom Master
washroom
Approved by
3000
3600
Nook Granted by
H.C.F
Earth
Signed by
SECTIONAL VIEW
A H
Project
A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION
3000
Master Bedroom
Bedroom
Client
Scale 1:100
3000
Recommended by
Approved by
Approved by
Granted by
FRONT VIEW
Signed by
5 1b
Project
A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION
Client
Description
FRONT & BACK VIEW
Scale 1:100
Drawn By : Checked By
WeBuildGHANA
0240020446 Drawing No.
BACK VIEW Date
SEPTEMBER 2022
NOTES.
H A
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.
Recommended by
Approved by
Approved by
Granted by
LEFT VIEW
Signed by
A H
Project
A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION
Client
Description
LEFT & RIGHT VIEW
Scale 1:100
Drawn By : Checked By
WeBuildGHANA
0240020446 Drawing No.
RIGHT VIEW Date
SEPTEMBER 2022
NOTES.
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.
1200
1500
1500
Approved by
Granted by
CODE w1 w2 w3 w4
LOCATION Washroom and Master washroom Kitchen & Laundry Living room/Dining Area & Master Bedroom Living room, Bedroom & Master Bedroom
Signed by
NUMBER REQUIRED 5 4 2 9
400
2150
2150
Project
A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION
CODE D1 D2 DD w5 Client
LOCATION Washroom and Master washroom Bedroom, Master Bedroom, Laundry Porch Staircase Mr. ABDUL KADIR ISAHAK
Lobby & Kitchen
NUMBER REQUIRED 5 13 3 3
Description
DOORS & WINDOWS SCHEDULES
Scale 1:100
Drawn By : Checked By
WeBuildGHANA
0240020446 Drawing No.
Date
SEPTEMBER 2022
NOTES.
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
balloon cage to svp termination
above roof level TO BE CHECKED VERIFIED ON SITE BY
4-1602 THE CONTRACTOR PRIOR TO
01 01 COMMENCING ANY WORKS.
15-1001-175
soil and vent pipe
Recommended by
Fence Wall Elevation
3000
flushing cistern
Approved by
floor fin.
5000 3000 4-1601
hardcore filling
2-12Ø 10 2 -12Ø
concrete
benching
225
450
to septic tank
Granted by
25 COVER
foundation concrete 150
2 - 12Ø 10 2 - 12Ø
450 BEAM / LINTEL SECTION 10 -10
300
Water Level
Signed by
750
1571
2550
2700
Water Level
1400
150
900
2700
1800
1800
1400
150
2100
866
150
SECTION b-b
SECTION a-a
Project
1200
1200
Client
750
4950
Scale 1:100
900
PLAN OF SEPTIC TANK SECTION c-c Drawn By : Checked By
SEPTIC TANK & SOAKAWAY SECTION d-d WeBuildGHANA
0240020446 Drawing No.
Date
SEPTEMBER 2022
STRUCTURES
NOTES.
A B C C1 D D1 E F G H
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
VARIOUS AGGREGATES.
1b 1b 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
1c 1c
12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
750 750 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
1500
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
1a 1a 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
F02 F02 F02 F02 AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
1 1
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
2 2 STRIP FOOTING
MINIMUM
COVER(mm)
-
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES
27.5 LITRES
0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
5 5 BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
1000
ASHANTI REGION
Client
FOUNDATION PLAN
Scale
A B C C1 D D1 E F G H Designed By
Drawn By
WEBUILD GH
Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
+3.65 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
50
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
70 70
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
500
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
+3.65
+3.65 WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
L=900
L=950
+0.50
GRADE C20/40.
50
50
4R16-6
50
1610
1610
1550
1550
500
200 300
500
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
±0.00 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
±0.00 REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
APPROVED.
1350
L=1650
1450
WITH.
L=1700
L=1700
2R14-2
2R16-7
2R16-7
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
1200
1200
L=3150
L=3150
19R8-3-175
16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
L=3550
L=3550
3050
L=3550
HIS APPROVAL OR OTHERWISE.
2R14-4
2R14-4
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
2R14-1
2R14-1
6R14-1
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
13R8-2-250
2650
19R8-3-175
3050
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
350
70 70
250
-1.20
2650
2650
A
125 200
3
MINIMUM
COVER(mm)
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES
VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)
VOLUME OF WATER
PER BAG OF CEMENT (L)
200
- 20 N/mm 1:3:6 0.11m3 0.21m3
125
STRIP FOOTING 0.55 27.5 LITRES
FOUNDATIONS-PAD
87.5
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES
250
175
1b A
30 N/mm 1:2:4 3
200
200
120
87.5
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES
200
200 . ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
125125 L=8509R8-4-175
A2 - INNER BOTTOM REINFORCEMENT
3050
3050
+0.50
100
+0.50 200
100
+0.50
87.5
100
175
120
A
2
87.5 200
SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) 125 200
200 125125 L=850
19R8-3-175
(Hook:100)
R8 0.395 130.6 51.6
125 87.5 250
175
250
1b E
120
120
87.5
200
200
Project
3 8 28 1000 28.00 200100 GROUND FLOOR R.C COLUMNS BENDING SCHEDULE
200 200 200 PROPOSED RESIDENTIAL 2-STOREY
SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) BUILDING TO BE BUILT AT
4 8 108 850 91.80 120
200
200100 120
AS SHOWN
2 8 52 1000 52.00 200
200100
200 200
Scale
3 8 228 850 193.80 120
200
200100 120 Designed By
WEBUILD GH
70 Drawing No.
4 14 20 3150 63.00 3050
Drawn By
WEBUILD GH
Date SEPTEMBER 2022
CONTACT
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
875
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
AT 28DAYS.
70 70 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
50
11R16-1-200
L=2650
VARIOUS AGGREGATES.
2000
250
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
11R16-2-200
AND MUST COMPLY WITH B.S.12.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
875
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
1900
100
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
F02 2000 / 2000 (d = 500) 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
4R14-1
L=3150
L=3150
22R8-2-150
ENGINEER.
2R14-1
2R14-1
3050
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
1400 9R16-3-200 L=2200 U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
L=2150
9R16-3-200
1500
HW - HARD WOOD
250
BM - BEAM
COL - COLUMN
9R16-4-200
100
3050
3050
+3.65 100
100
1b
75150
F01 1500 / 1500 (d = 500)
1b 200
75150 200 75
75 A
100
100
200
A
100
100
200
125125 22R8-2-150
L=800 (Hook:100)
125125 22R8-2-150
L=800 (Hook:100) 250
250
4C1
3C1 (150/250) PAD FOUNDATION BENDING SCHEDULE
(150/250) SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) Project
PROPOSED RESIDENTIAL 2-STOREY
R16 1.580 885.2 1,398.8
BUILDING TO BE BUILT AT
FIRST FLOOR R.C COLUMNS BENDING SCHEDULE SECOND FLOOR R.C COLUMNS BENDING SCHEDULE T.WEIGHT (Kg) 1,398.8 PARKUSU -ASOKORE MAMPONG MUNICIPALITY
SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) ASHANTI REGION
SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) NO SIZE QUA LENGTH (mm) TOTAL FORM
R8 0.395 281.6 111.2 Client
R8 0.395 246.4 97.3
1 16 132 2668 352.18 390 1900 390
AS SHOWN
1400
NO SIZE QUA LENGTH (mm) TOTAL FORM
NO SIZE QUA LENGTH (mm) TOTAL FORM
4 16 43 2136 91.85 370
1400
370
70 Scale
1 14 56 3550 198.80 3510 1 14 64 3150 201.60 3050
Designed By
2 8 308 800 246.40 100
200100
200 100 2 8 352 800 281.60 100
200100
200 100 WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
A B C C1 D D1 E F G H
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
1C1 (250/250) 1C15 (250/250) 1C2 (250/250) 1C16 (250/250) 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
1b 1b
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
1B25 150/300 1B26 150/300 1B27 150/300 REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
1c 1c
13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
1a 1a
1B12 150/300
1B20 150/300
1B24 150/300
1B21 150/300
16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
2 2
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
1B13 150/300
1B17 150/300
1B18 150/300
1B22 150/300
1B19 150/300
1B14 150/300
1B23 150/300
4 4
Project
PROPOSED RESIDENTIAL 2-STOREY
1C11 (175/250) 1C12 (175/250) 1C13 (175/250) 1C14 (175/250) BUILDING TO BE BUILT AT
A B C C1 D D1 E F G H
Description
700
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.
600
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
850 2R12-5(TT) 650 2R12-1(TT) 2R12-1(TT) 2R12-1(TT) 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.
2R12-1(TT) 600 2R12-4(TT) 500 2R12-6(TT) 2R12-7(TT) 17R8-3-175 17R8-3-175 17R8-3-175 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
300
300
300
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
215
230
VARIOUS AGGREGATES.
17x1R8-3-175 13x1R8-3-175 18x1R8-3-175
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
2R12-2(BB) 2R12-2(BB) 2R12-2(BB) AND MUST COMPLY WITH B.S.12.
2R12-2(BB)
150 150 150 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
2875 87.5
87.5 2105 87.5
87.5 2975 87.5
87.5 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
A C F H
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
650
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
300
300
300
18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
1975 87.5
87.5 3905 87.5
87.5 2075 87.5
87.5 . ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
A D E H BM - BEAM
COL - COLUMN
700 900
(3) 1 (3) 2 (3) 3 550 600 2R12-4(TT)
850 2R12-5(TT) 650 2R12-1(TT) 2R12-1(TT) 2R12-1(TT)
2R12-1(TT) 600 2R12-4(TT) 500 2R12-6(TT) 2R12-7(TT) 17R8-3-175 17R8-3-175 17R8-3-175
1B6 150/300 1B7 150/300 1B8 150/300
300
300
300
215
215
230
230
5 3 5 3
2700 2700
Project
(F) 1 (F) 2 (F) 3 PROPOSED RESIDENTIAL 2-STOREY
(C) 1 (C) 2 (C) 3
2R12-19(TT)
2R12-19(TT) BUILDING TO BE BUILT AT
2R12-19(TT)
2R12-19(TT) PARKUSU -ASOKORE MAMPONG MUNICIPALITY
1B16 150/300
15R8-3-175 1B19 150/300
15R8-3-175
15x1R8-3-175 Client
15x1R8-3-175
MR. ABDUL KADIR ISAHAK
2R12-19(BB) 2R12-19(BB)
2R12-19(BB) 2R12-19(BB)
150 150 Description
2700 3450 3850 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
1000 1100
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.
750 950
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
600 600
GRADE C20/40.
2R12-13(TT) 2R12-15(TT) 2R12-16(TT) 2R14-17(TT) 2R12-18(TT)
1B14 150/300 1B13 150/300 1B12 150/300
6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
2R12-14(BB)
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
(A) 1 (A) 2 (A) 3 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
15R8-3-175 15R8-3-175 15R8-3-175 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
300
300
300
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
2R12-14(BB) 2R12-14(BB) 2R12-14(BB) COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
(A) 1 - 1 (A) 2 - 2 (A) 3 - 3 AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
3450 3850
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)
1100
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES
600
25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES
300
300
COL - COLUMN
19x1R8-3-175 21x1R8-3-175 G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
A D E H
3050 2280 3150
2R12-23(BB)
Project
(1b) 1 (1b) 2 (1b) 3 PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
125125 2800 125125 2030 125125 2900 125125 PARKUSU -ASOKORE MAMPONG MUNICIPALITY
2R12-6(TT) ASHANTI REGION
2R12-22(TT) 2R12-22(TT) 2R12-22(TT) Client
17R8-3-175 17R8-3-175 17R8-3-175
MR. ABDUL KADIR ISAHAK
300
300
300
Description
GROUND FLOOR R.C COL. DET. 2/3
2R12-23(BB) 2R12-23(BB) 2R12-23(BB)
Scale
150 150 150
Designed By
WEBUILD GH
(1b) 1 - 1 (1b) 2 - 2 (1b) 3 - 3 Drawing No.
Drawn By
WEBUILD GH
SEPTEMBER 2022
CONTACT
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
3 2 1b
MEASURED AND REIMBURSED ACCORDINGLY.
3450 3850
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
1100
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
(D) 1 (D) 2 (D) 3
600 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
950
GRADE C20/40.
2R12-20(TT) 2R12-20(TT) 2R14-17(TT) 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
600
WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
2R12-20(TT) 2R14-17(TT) 2R12-18(TT) AT 28DAYS.
300
300
300
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
19x1R8-3-175 21x1R8-3-175
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
2R12-21(BB) 2R12-21(BB) 2R12-21(BB) 2R12-21(BB) WORKS.
150 150 150 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
(D) 1 (D) 2 (D) 3
13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
125125 3200 125125 3600 125125 (D) 1 - 1 (D) 2 - 2 (D) 3 - 3 CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
5 3 2 1b
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
2700 3450 3850 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
750 950 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
2R12-13(TT) 600 2R12-15(TT) 2R12-16(TT) 600 2R14-17(TT) 2R12-18(TT)
1B23 1B22 1B21
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
180180 180180 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
GROUND FLOOR R.C BEAMS BENDING SCHEDULE R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
2R12-15(TT) BM - BEAM
2R12-13(TT) 2R12-13(TT) 2R12-13(TT) SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
15R8-3-175 15R8-3-175 15R8-3-175 R8 0.395 349.4 138.0
R12 0.889 328.0 291.6
300
300
300
100 100
100
2930
7 12 4 3200 12.80 230
2080
8 12 2 2350 4.70 230
12 12 2 2450 4.90
2180
230
Project
2620 PROPOSED RESIDENTIAL 2-STOREY
13 12 4 2800 11.20 180
BUILDING TO BE BUILT AT
14 12 4 10550 42.20 10180
180 180
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
15 12 4 1700 6.80 1700
ASHANTI REGION
16 12 4 2750 11.00 2730
Client
17 14 8 2000 16.00 1990
18 12 8 3700 29.60
3480
180
MR. ABDUL KADIR ISAHAK
2830
19 12 8 3250 26.00 180 220
Description
20 12 4 3400 13.60 180
3180
GROUND FLOOR R.C COL. DET. 3/3
21 12 4 7850 31.40 180
7480
180
Scale
22 12 2 3100 6.20
2880
180
Designed By
23 12 2 9050 18.10 180
8660
180 WEBUILD GH
Drawn By Drawing No.
24 12 2 2000 4.00 1960
WEBUILD GH
25 12 2 1550 3.10 1530 SEPTEMBER 2022
26 12 2 3150 6.30
2950
180
CONTACT
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
A B C C1 D D1 E F G H
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
1b 1b
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
d=175 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
1c 1c
WORKS.
1a 1a
14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
2B26 150/500
2B27 150/500
2B31 150/500
TENSILE AND OTHER RELEVANT TESTS.
2S1 2S2 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
d=175 d=175
16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
1 2B24 150/500
1 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
2S3
20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
d=175
2 2
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
2B13 150/500
2B17 150/500
2B18 150/500
2B22 150/500
HW - HARD WOOD
2S4 2S5 2S6 BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
d=175 d=175 d=175 R.C. - REINFORCED CONCRETE
3 d=175
2B6 150/500 2B7 150/500 2B8 150/500
3
2B16 150/500
2B19 150/500
2B14 150/500
2B23 150/500
2C11 (175/250) 2C12 (175/250) 3C17 (150/250) 2C13 (175/250) 2C14 (175/250)
Project
5 2B25 150/500 2B9 150/500 2B10 150/500 2B11 150/500
5 PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
Client
5330 3150 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
900
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
(1b) 1 (1b) 2 (1b) 3
650
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
2R16-1(TT) 800 2R16-4(TT) 2R12-5(TT) 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
VARIOUS AGGREGATES.
180
500
500
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
280
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
150 150
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
125125 5080 125125 2900 125125 HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
3050 2280 3150 OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
550
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
550 2R16-11(TT)
650
850 650
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
2R12-10(TB) AS SHOWN IN THE TABLE (1) :
2R14-7(TT) 2R12-10(TB)
2R14-7(TT) 700 2R16-9(TT) 500 2R14-12(TT) 2R12-13(TT)
2B6 150/500 2B7 150/500 2B8 150/500 175
11R8-3-300
175 175
11R8-3-300
175 STRIP FOOTING
FOUNDATIONS-PAD
MINIMUM
COVER(mm)
-
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES
0.55
VOLUME OF WATER
PER BAG OF CEMENT (L)
27.5 LITRES
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES
25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES
500
500
360
. ABBREVIATIONS
11x1R8-3-300 8x1R8-3-300 11x1R8-3-300 A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
700
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
2R12-8(BB) 2R16-14(BB) 2R12-8(BB) 2R12-8(BB) BM - BEAM
150 150
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
(3) 1 (3) 2 (3) 3
2875 87.5
87.5 2105 87.5
87.5 2975 87.5
87.5 (3) 1 - 1 (3) 3 - 3
5 3 2 1b
2700 3450 3850
2R12-16(BB)
500
Description
FIRST FLOOR R.C BEAMS DET. 1/4
Scale
2R12-16(BB) 2R12-16(BB)
150 150 Designed By
WEBUILD GH
Drawn By Drawing No.
(A) 1 - 1 (A) 3 - 3 WEBUILD GH
SEPTEMBER 2022
CONTACT
0240020446
NOTES.
5 3 5 3 1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
(C) 1 (C) 2 2700 (C) 3 (F) 1 (F) 2 2700 (F) 3 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
2R12-21(TT) 2R12-21(TT) WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
2R12-21(TT) 2R12-21(TT) 3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
180 180 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
180 180
GRADE C20/40.
500
500
9x1R8-3-300 9x1R8-3-300 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.
2R12-21(BB) 2R12-21(BB) 2R12-21(BB) 2R12-21(BB) 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
150 150 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
(C) 1 (C) 2 (C) 3 (F) 1 (F) 2 (F) 3 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
3450 3850 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
(D) 1 (D) 2 (D) 3 1100 FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
950 2R12-25(TB)
2R12-22(TT) 2R12-22(TT) 2R12-25(TB)
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
180
150/500 150/500
180 175 175 175 175 175 175 COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
500
500
500
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
280
12x1R8-3-300 13x1R8-3-300
20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.
850
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :
2R14-23(BB) 2R16-26(BB) 2R14-23(BB) 2R14-23(BB) 2R14-23(BB)
125
1125 3200 125125 3600 125125
25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
40 N/mm 1:1 :3 0.053m3 0.105m3 0.5
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
3 2 1b
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
500
500
12x1R8-3-300 13x1R8-3-300
220
E H
(1) 1 (1) 2 3150 (1) 3
ASHANTI REGION
500
500
500
11x1R8-3-300
250
Client
2700 3450 3850 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
650 600
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
2R12-15(TT) 600 2R12-28(TT) 2R12-18(TT) 600 2R14-19(TT) 2R12-20(TT) 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
180 180 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
2R12-16(BB) 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
125125 2450 125125 3200 125125 3600 125125 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
2R12-28(TT) STRUCTURAL ENGINEER.
2R12-15(TT) 2R12-15(TT) 2R12-15(TT) 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
9R8-3-300 9R8-3-300 9R8-3-300 OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
500
500
500
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
50
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES
30 N/mm 1:2:4 3
0.07m 0.14m3
VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)
0.55
0.55
VOLUME OF WATER
PER BAG OF CEMENT (L)
27.5 LITRES
27.5 LITRES
600
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES
750
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
(5) 1 (5) 2 (5) 3 2R14-31(TT) 750 500 2R16-34(TT) 2R14-36(TT) 700 3R16-34(TT)
2B25 150/500 2B9 150/500 2B10 150/500 2B11 150/500
360
395
355
2850 1000
500
500
ASHANTI REGION
Client
550
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.
700 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
550
5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
650
6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
550 500
WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
850 650
7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
2R12-10(TB) 2R12-48(TB) OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
(2) 1 (2) 2 (2) 3 2R14-31(TT) 2R16-43(TT) 700 2R16-9(TT) 500 2R14-12(TT) 2R12-13(TT)
VARIOUS AGGREGATES.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
230
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
395
WORKS.
230
750 1300 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
850 700
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
2R12-42(BB) 2R16-46(BB) 2R12-49(BB)
700 R14-44(BT)
14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
700
STRUCTURAL ENGINEER.
987.5 87.5
87.5 2875 87.5
87.5 2105 87.5
87.5 2975 87.5
87.5
HIS APPROVAL OR OTHERWISE.
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
500
500
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
(2) 1 - 1 (2) 2 - 2 (2) 3 - 3 U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
SIZE
NO
R16
R14
R12
R10
R8
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
6
5
4
2
1
12
12
12
16
16
14
16
12
12
16
14
14
16
14
12
16
16
12
14
12
12
12
14
16
12
16
14
12
12
12
14
12
14
12
12
16
12
14
16
12
16
12
14
12
12
16
16
16
8
2
2
2
2
3
1
2
2
2
2
2
3
2
2
7
3
2
2
2
2
4
2
4
8
4
4
2
4
4
2
4
2
4
4
2
2
2
2
2
2
LENGTH (mm)
10550
1.580
1.210
0.889
0.617
0.395
1250
3350
1100
1400
3650
2050
1500
2050
4000
2450
2550
1300
2700
5450
3300
1250
1750
1150
1950
3100
3100
3750
1700
7950
5050
1350
2000
3600
3400
3300
3700
2000
2750
1700
2800
4250
3200
1500
2050
1050
1500
5500
3250
3300
3150
2300
1250
6450
5100
T.WEIGHT (Kg)
LENGTH (m)
TOTAL
337.50
18.75
16.35
12.25
12.40
15.00
15.90
10.10
13.60
26.40
29.60
11.00
42.20
11.20
12.80
11.00
12.90
10.20
121.7
233.2
337.5
6.70
2.20
2.80
7.30
6.15
1.50
4.10
8.00
4.90
7.65
2.60
5.40
6.60
2.50
3.45
3.90
6.20
3.40
2.70
8.00
7.20
8.00
3.40
8.50
6.00
4.10
4.20
6.00
6.50
6.60
6.30
4.60
75.5
18.8
Project
PROPOSED RESIDENTIAL 2-STOREY
250
220
180
180
BUILDING TO BE BUILT AT
360
400
220
180
180
230
300
280
280
T.WEIGHT (Kg)
420
430
2180
2180
4770
3480
3890
2930
3080
2950
10180
ASHANTI REGION
1070
1400
3650
2030
1470
2010
3970
1270
2660
5450
3280
1210
1730
1110
3070
3230
1700
7480
1310
1990
2830
1990
2730
1700
1490
2040
1050
1470
2290
100
100
90
90
1570
2660
3380
3180
2620
5260
2950
6150
4790
420
120
430
100
Client
635.8
192.2
207.3
133.3
230
230
360
280
180
360
230
180
180
91.3
11.6
250
220
250
180
A B C C1 D D1 E F G H
MEASURED AND REIMBURSED ACCORDINGLY.
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
1b 1b
6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
2S11 WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
100 100 100 AT 28DAYS.
5R12-5-150
L=800
L=850
L=800
L=1100
100
100
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
860
9R12-5-250
20R12-26-150
20R12-25-150
5R12-19-150 L=3250 SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
1c 1c
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
100 AND MUST COMPLY WITH B.S.12.
15R12-2-250 L=850 15R12-4-250 L=2300 15R12-5-250 L=800 R12 0.889 1,375.4 1,222.6
100
100
2B27 150/500
2B31 150/500
L=3950
WITH.
2S1 2S2 1 12 37 3150 116.55 3150
14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
100 TENSILE AND OTHER RELEVANT TESTS.
12R12-13-250
9R12-13-250
3R12-20-250 L=650 3R12-5-250 L=800 6 12 35 2250 78.75 2250 AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
d=175
100
3R12-19-250
2B24 150/500
12R12-17-250 L=900
L=3250 670
670
L=1800
L=2350
8 12 20 2050 41.00
2 2
2040
20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
100 ENGINEER.
L=800
12R12-6-250
9R12-15-250
12R12-18-250
2B29 150/500 2B3 150/500 2B4 150/500 2B5 150/500 9 12 11 2350 25.85 2350
670
13 12 21 3950 82.95
25 25 LITRES
1/2
3950
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
2B13 150/500
2B17 150/500
2B18 150/500
2B22 150/500
100
L=3550
L=3550
L=3550
9R12-12-250
12R12-12-250
COL - COLUMN
3490 22R12-22-150 L=3600 22R12-18-150 L=2350 750 16 12 12 2350 28.20 2310
G.A - GENERAL ARRANGEMENT
100
2C7 (175/250) 2C8 (175/250) 2C9 (175/250) 2C10 (175/250) 20 12 3 650 1.95 640
7R12-24-150
L=2250
L=2050
L=2350
2S7
3 3 21 12 40 1100 44.00 1100
d=175
12R12-6-250
9R12-8-250
12R12-16-250
100
23 12 22 850 18.70 750
2B19 150/500
2B14 150/500
2B23 150/500
L=2800
16R12-11-250 L=2800
L=2800
9R12-11-250
11R12-5-250 L=800 d=175 11R12-8-250 L=2050 d=175 11R12-10-250 L=2100 d=175 11R12-5-250 L=800
100
100
L=800
L=800
680
2C11 (175/250) 2C12 (175/250) 3C17 (150/250) 2C13 (175/250) 2C14 (175/250)
670
670
670
16R12-5-250
7R12-5-150
8R12-5-250
9R12-5-250
5 100
2B10 150/500
100
2B11 150/500
5 Project
PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
A B C C1 D D1 E F G H Client
A B C C1 D D1 E F G H
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
1b 3S19
1b
VARIOUS AGGREGATES.
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
1c 1c
12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
1a 1a
TENSILE AND OTHER RELEVANT TESTS.
3B26 150/500
3B32 150/500
3B6 150/500
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
3S11 FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
d=175 3S12
16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
d=175
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
3S13
1 1
18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
d=175
3B24 150/500 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.
3C3 (150/250) 3C16 (150/250) 3C5 (150/250) 3C6 (150/250) 21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
2 2
AS SHOWN IN THE TABLE (1) :
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
3B13 150/500
3B18 150/500
3B22 150/500
BM - BEAM
3S14 3S15 COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
d=175 d=175
3S16
d=175
3C7 (150/250) 4C18 (150/250) 3C9 (150/250) 3C10 (150/250)
3S17
3B14 150/500
3B33 150/500
3B23 150/500
d=175 3S18
4 d=175 4
A E H
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
5330 3150
2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
1400
5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.
2R12-1(TT) 2R12-4(TT)
600
6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
2R12-1(TT) 2R12-4(TT) 2R12-5(TT) WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
250
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
500
500
320
18x1R8-3-300 11x1R8-3-300
250
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
150 150
APPROVED.
(1b) 1 - 1 (1b) 3 - 3 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
5 3 2 1b
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
2700 3450 3850 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
650 600 AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
750 950 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.
180 180
AS SHOWN IN THE TABLE (1) :
180
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)
220
/ 50 0.55 27.5 LITRES
. ABBREVIATIONS
125125 2450 125125 3200 125125 3600 125125 G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
2R12-9(TT)
2R12-7(TT) 2R12-7(TT) 2R12-7(TT)
9R8-3-300 9R8-3-300 9R8-3-300
175 175 175 175
500
500
500
500
500
Scale
Designed By
2R12-14(BB) 2R12-14(BB) 2R12-14(BB) WEBUILD GH
SEPTEMBER 2022
(H) 1 - 1 (H) 2 - 2 (H) 3 - 3 CONTACT
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
E H
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
2 1b
MEASURED AND REIMBURSED ACCORDINGLY.
2R12-16(TT) 3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
2R12-16(TT) OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.
AT 28DAYS.
500
500
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.
13x1R8-3-300
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
2R12-16(BB) 2R12-16(BB)
7575 3000 7575 150
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
(1) 1 (1) 2 (1) 3 3R16-36(BB) 3R16-36(BB) 3R16-36(BB) REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
(1) 1 - 1
2R12-37(BT) 150 2R12-37(BT) 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
150
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
125125 3600 125125 (D1) 1 - 1 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
(D1) 1 (D1) 2 (D1) 3 CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
(D1) 2 - 2
14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
A E H 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
900
HIS APPROVAL OR OTHERWISE.
1650 650 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
(5) 1 (5) 2 (5) 3 2R12-18(TT) 650 2R12-20(TT) 600 2R16-23(TT) 2R12-5(TT) 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
250
400
250
AS SHOWN IN THE TABLE (1) :
500 700
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)
700
/ 50 0.55 27.5 LITRES
1650 2R12-22(BT)
3050
25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
(5) 1 (5) 2 (5) 3 A2 - INNER BOTTOM REINFORCEMENT
500
500
2R16-23(TT)
500
500
380
380
18x1R8-3-300 11x1R8-3-300
250
Description
SECOND FLOOR R.C BEAMS DET. 2/4
4R16-31(BB) 700 2R12-6(BB)
Scale
2R14-32(BT)
3050 Designed By
WEBUILD GH
(3) 1 (3) 2 (3) 3 Drawing No.
7575 5180 7575 3000 7575 Drawn By
WEBUILD GH
SEPTEMBER 2022
CONTACT
0240020446
NOTES.
A D1 E H
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
1075 3680 1650 3150 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
1650 650 900 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
650 650
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
1000 2R14-27(TT) 500 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.
250250
VARIOUS AGGREGATES.
400
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
5x1R8-3-300 13x1R8-3-300 6x1R8-3-300 11x1R8-3-300 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
700
WORKS.
2R12-17(BB) 2R16-25(BB) 2R12-28(BB) 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
1550 WITH.
1000 7575 3530 7575 1500 7575 3000 7575 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
175 175 175 COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
500
500
500
5 3 (2) 3 - 3
2 1b
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES
. ABBREVIATIONS
1000 1100
HW - HARD WOOD
BM - BEAM
(E) 1 (E) 2 (E) 3 COL - COLUMN
750 950
R.C. - REINFORCED CONCRETE
2R12-14(BB)
2R16-38(TT)
2R12-7(TT) 2R12-7(TT) 2R12-7(TT)
9R8-3-300 9R8-3-300 9R8-3-300
175 175 175 175 175 175
Project
500
500
500
FIRST FLOOR R.C BEAMS BENDING SCHEDULE 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.
R8 0.395 316.3 124.9 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.
R12 0.889 253.0 224.9 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
R14 1.210 46.7 56.5 8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.
R16 1.580 96.2 152.0 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
T.WEIGHT (Kg) 558.3 AND MUST COMPLY WITH B.S.12.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
NO SIZE QUA LENGTH (mm) TOTAL FORM WORKS.
4 12 2 2250 4.50 2240 FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
2930
5 12 6 3200 19.20 250 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
6 12 6 3350 20.10 3080
250 HIS APPROVAL OR OTHERWISE.
2620
7 12 6 2800 16.80 180 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
8 12 2 6300 12.60 180
6080
3480
12 12 6 3700 22.20 180
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :
15 12 2 2000 4.00
30 N/mm 1:2:4 3
0.07m 0.14m3
1990 / 50 0.55 27.5 LITRES
4660
30 14 2 5000 10.00 320
3080
34 16 3 3500 10.50 380
4030
35 12 2 4400 8.80 180 180
I A B C C1 D D1 E F G H
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
3C1 (150/250) 3C15 (150/250) 3C2 (150/250) 3C4 (150/250) WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.
1b 3S19
1b
7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
100 100 100
L=800
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
L=1100
L=950
VARIOUS AGGREGATES.
L=900
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
810
860
5R12-14-150
10R12-5-150
L=650
23R12-19-150
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
20R12-25-150
20R12-24-150
670
1c 1c
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
100 REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
25R12-2-150 L=950 25R12-4-150 L=2650 25R12-5-150 L=800 WORKS.
100
100
830 25R12-1-150 L=3800 25R12-3-150 L=1750 670 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
3B28 150/500
3B32 150/500
3B6 150/500
L=3950
L=3950
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
3S11 SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg)
TENSILE AND OTHER RELEVANT TESTS.
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
23R12-17-150
10R12-17-150
T.WEIGHT (Kg) 1,567.1 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
d=175 OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
NO SIZE QUA LENGTH (mm) TOTAL FORM 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
3S13
1 1
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
100
1 12 25 3800 95.00 3780
L=800
4R12-14-150 d=175
3B24 150/500
20R12-21-150 L=900
100
3C3 (150/250) 3C16 (150/250) 3C5 (150/250) 3C6 (150/250) 3 12 25 1750 43.75 1750
L=2650
L=2350
ENGINEER.
20R12-22-150
6 12 31 1100 34.10
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)
1100 STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 0.55 27.5 LITRES
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES
7 12 39 5450 212.55
27.5 LITRES
5430 25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES
100 . ABBREVIATIONS
8 12 22 4000 88.00 3870
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
9 12 48 3250 156.00
3B13 150/500
3B18 150/500
3B22 150/500
20R12-16-150
100
L=2350
20R12-20-150
3B33 150/500
3B23 150/500
34R12-15-150 L=2800
20R12-15-150 L=2800
d=175 3S18
4 d=175 4 21
22
12
12
20
20
900
2350
18.00
47.00
900
2330
L=800
680
20R12-5-150
5 3B25 150/500
100
3B30 150/500
100
3B31 150/500
5 Project
PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
Client
A B C C1 D D1 E F G H
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
4C1 (150/250) 4C15 (150/250) 4C2 (150/250) 4C4 (150/250) 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
1b 1b
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
4B1 150/350 4B2 150/500 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
WITH.
1a 1a
TENSILE AND OTHER RELEVANT TESTS.
4B26 150/350
4B32 150/350
4B3 150/500
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
1 1
18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
4B24 150/350
20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.
2 2
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :
4B34 150/350 4B35 150/350 4B36 150/350 4B5 150/350 MINIMUM 28-DAY MIX-DESIGN VOL. OF FINE VOL. OF COARSE
WATER/CEMENT VOLUME OF WATER
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
4B38 150/350
4B13 150/350
4B40 150/350
4B18 150/350
4B22 150/350
BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
4B14 150/350
4B41 150/350
4B33 150/350
4B23 150/350
4 4
5330 (1b) 4 (1b) 5 3150 (1b) 6 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
600
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.
600
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
2R12-1(TT) 2R12-4(TT) 2R12-5(TT)
4B1 4B2 24R8-3-225 24R8-3-225 24R8-3-225 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
250
350
350
350
7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
24x1R8-3-225 OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
11x1R8-7-300
250
VARIOUS AGGREGATES.
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
2R12-2(BB) 2R12-6(BB) 2R12-2(BB) 2R12-2(BB) 2R12-2(BB) 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
(1b) 1 (1b) 2 (1b) 3 WORKS.
(1b) 1 - 1 (1b) 2 - 2 (1b) 3 - 3 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
(1b) 4 (1b) 5 (1b) 6 COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
5180 7575 3000 7575 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
5 3 2 1b
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
2700 3450 3850 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
1000 1100
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
750 950
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
2R12-8(TT) 600 2R12-10(TT) 2R12-11(TT) 600 2R12-12(TT) 2R12-13(TT) 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
4B14 150/350 4B13 150/350 4B26 150/350 19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
180 180 AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
180 180 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.
12x1R8-3-225 15x1R8-3-225 17x1R8-3-225
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :
2R12-9(BB)
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
2R12-10(TT) U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
2R12-8(TT) 2R12-8(TT) 2R12-8(TT) R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
12R8-3-225 12R8-3-225 12R8-3-225 BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
350
350
350
2R12-14(BB) 2R12-15(BB)
250
(H) 1 (H) 2 (H) 3
Project
(H) 4 (H) 5 (H) 6
PROPOSED RESIDENTIAL 2-STOREY
125125 2450 125125 3200 125125 3600 125125 BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
2R12-10(TT) Client
2R12-8(TT) 2R12-8(TT) 2R12-8(TT)
12R8-3-225 12R8-3-225 12R8-3-225 MR. ABDUL KADIR ISAHAK
Description
350
350
Scale
2R12-14(BB) 2R12-14(BB) 2R12-14(BB) Designed By
150 150 150 Drawn By
WEBUILD GH
Drawing No.
WEBUILD GH
(H) 1 - 1 (H) 2 - 2 (H) 3 - 3 SEPTEMBER 2022
CONTACT
0240020446
NOTES.
E H
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
2R12-6(TT) 3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
2R12-6(TT) OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.
4B24 150/350
14R8-3-225 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
350
7575 3000 7575 150 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
(1) 1 (1) 2 (1) 3 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
(1) 1 - 1 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
A E H
12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
1075 5330 3150 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
900 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
1750 600
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
1400 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
650 600
STRUCTURAL ENGINEER.
(5) 1 (5) 2 (5) 3 2R12-17(TT) 2R12-18(TT) 2R12-20(TT) 2R12-5(TT)
4B25 150/350 4B30 150/350 4B31 150/350 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
250
250
6x1R8-3-225 24x1R8-3-225 14x1R8-3-225 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
1000
ENGINEER.
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
350
350
350
2R12-9(BB)
350
350
A D1 E H
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
1000 500
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
2R12-25(TT) 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.
(2) 1 (2) 2 (2) 3 2R12-17(TT) 2R12-23(TT) 600 2R12-24(TT) 400 2R12-26(TT) 2R12-5(TT)
4B34 4B35 4B36 4B5
6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
150/350 150/350 150/350 150/350 WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.
250
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.
6x1R8-3-225 17x1R8-3-225 8x1R8-3-225 14x1R8-3-225
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
2R12-22(BB) 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
(2) 1 (2) 2 1000(2) 3 7575 3530 7575 1500 7575 3000 7575 CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
2R12-17(TT) 2R12-17(TT) 2R12-17(TT) 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
6R8-3-225 6R8-3-225 6R8-3-225 STRUCTURAL ENGINEER.
350
350
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
2R12-22(BB) 2R12-22(BB) 2R12-22(BB) 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
150 150 150 19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
900
1750 650
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)
1400
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES
650 600
25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
(3) 1 (3) 2 (3) 3 2R16-27(TT) 2R12-18(TT) 2R16-30(TT) 2R12-5(TT) 25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES
250
250
250
U2 - INNER TOP REINFORCEMENT
6x1R8-3-225 24x1R8-3-225 14x1R8-3-225 R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
COL - COLUMN
700 700
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
2R12-16(BB) 2R16-28(BB) 2R12-21(BB)
50 2R12-29(BT)
3050
1000
(3) 1 (3) 2 1000(3) 3 7575 5180 7575 3000 7575
2R16-27(TT) 2R16-27(TT) 2R16-27(TT)
6R8-3-225 6R8-3-225 6R8-3-225
350
350
350
5 3 2 Project
2700 3450 PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
(I) 1 (I) 2 (I) 3
950 PARKUSU -ASOKORE MAMPONG MUNICIPALITY
600 2R12-33(TT)
ASHANTI REGION
750 2R12-31(TT) 2R12-31(TT) 2R12-31(TT)
2R12-31(TT) 600 2R12-33(TT) 2R12-34(TT)
4B39 4B38 12R8-3-225 12R8-3-225 12R8-3-225 Client
150/350 150/350
MR. ABDUL KADIR ISAHAK
250
250
250
250
350
350
350
12x1R8-3-225 16x1R8-3-225
Description
5 3 2 1b
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
650 600 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
750 950
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
4B41 150/350 4B40 150/350 4B32 150/350 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
180 180 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
12x1R8-3-225 15x1R8-3-225 17x1R8-3-225 VARIOUS AGGREGATES.
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
2R12-9(BB)
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
(D1) 1 (D1) 2 (D1) 3 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
2R12-10(TT) 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
2R12-8(TT) 2R12-8(TT) 2R12-8(TT)
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
12R8-3-225 12R8-3-225 12R8-3-225 FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
350
350
SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
T.WEIGHT (Kg) 539.2 21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :
4570 -
1 12 2 4850 9.70
STRIP FOOTING 20 N/mm 1:3:6 0.11m3 0.21m3 0.55 27.5 LITRES
FOUNDATIONS-PAD
250 / 50 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
100 100
100
2620
8 12 8 2800 22.40 180
3480
13 12 8 3700 29.60 180
2850
17 12 4 3150 12.60 260
Project
23 12 2 2200 4.40 2160
3150
Designed By
34 12 2 3400 6.80 250
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
2H8-8-140 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
11H12-4-100
11H12-1-100 16H WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
2300 8-7
AT 28DAYS.
200 -23
0
7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
120 400 120 400 VARIOUS AGGREGATES.
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
16H 300 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
8-7
-23 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
560
410
0 11H12-5-100
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
L=2100
APPROVED.
560
11H12-15-100
144011H12-6-100 L=2200
560
WITH.
11H12-4-100 L=950
6H8-10-200 L=2300 2260
6H8-10-200 L=2300 2260 3660 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
370 HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
11H
1100560
300
12-2 6H8-10-200
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
11H -10
270
STRUCTURAL ENGINEER.
12-1 0
1350
L=46
11H12-6-100
1075 150 1075 -100
L=
50 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
4500 HIS APPROVAL OR OTHERWISE.
1690
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
300
400
600
1690 11H12-5-100 L=2500 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
600
400
560 21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :
120
144011H12-6-100 L=2200
50
B-B
L=47
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES
25 25 LITRES
1/2
2700
12-1
L=44
4650
. ABBREVIATIONS
0 L=
00
11H12-15-100
00
300
0 L=45
HW - HARD WOOD
BM - BEAM
11H
11H
COL - COLUMN
6H8-10-200
-10
3660
400
6H8-10-200
3660
3660
50
L=12
11H12-16-100
11H12-13-100 L=1550 4-100 600
0
300
16H
3660
11H12-12-100
11H
300
740
200 -23
0 11H12-15-100
490
1100 L=2100
T. WEIGHT (kg) 357.1
8-7
2H8-9-140
150 L=1100 1060 2H8-9-140 L=1100 1060
16H
270
560
500
120 400
1 12 11 4500 49.50
3660
600 560 560
290
400
2 12 11 4650 51.15
3660
410
560
120
B
11H12-16-100 L=1800
410
2H8-17-140
1350
11H12-11-100 3 12 11 750 8.25
570
290
150
300
2H8-9-140 370
00
4 12 11 950 10.45 270 300
00
L=44
11H12-14-100
2-1 5 12 11 2500 27.50
1690
2-1
400
50
00
400
L=47
12-1
600 120
12 12 11 4400 48.40
3660
50 Client
400
00 600
500 L=12 170 560
4-1
12-1
120
13 12 11 1550 17.05
400
490
11H
400
A-A
14 12 11 1250 13.75 120
490
600
Description
400
R.C STAIRS DETAILS
Scale
16 12 11 1800 19.80 300
1350
120
Designed By
17 8 2 0 0.00 WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT
0240020446