Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Screenshot 2023-09-09 at 1.59.01 PM

Download as pdf or txt
Download as pdf or txt
You are on page 1of 37

A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING

LOCATION
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL -
ASHANTI REGION

CLIENT
Mr. ABDUL KADIR ISAHAK

DATE
SEPTEMBER 2022
NOTES.
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
A B C D E F G H TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.
8480
1200 950 900 2280 900 1050 1200 Recommended by

1b 1b
Approved by
3050

3050

Approved by
1830
Fill

1 1
1350
800

800

750 750 Granted by


2 2
2600 1830 2700
10000

10000

Signed by
3800

3800
3450

3450
Fill

Fill

Fill
5700

3 3
1350

1350
Fill
900

Project
4 4
Fill

2250
Fill

A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING


1350

1350

AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION


Fill
900

1700 3630 1800

5 5 Client

Mr. ABDUL KADIR ISAHAK

1200 950 900 2280 900 1050 1200


Description
FOUNDATION PLAN
8480
Scale
A B C D E F G H Drawn By :
1:100

Checked By
WeBuildGHANA
0240020446 Drawing No.

Date
SEPTEMBER 2022


FOUNDATION PLAN
NOTES.
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
A B C D E F G H TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.
8480
1200 950 900 2280 900 1050 1200 Recommended by

1b 1b
Approved by
3050

3050

Approved by
2430

Porch
1800

1 1
800

800

1050 1050 Granted by


2 DD 2
2900 2130 3000
10000

10000

Signed by
4100

4100
Bedroom

Bedroom
3450

3450
w4

w4
6000

D2 D2

3 D1 3
1350

1350
1200

D2
washroom Nook
w1

Project
Kitchen

4 4
2550

w2

A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING


1350

1350

AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION


1200

washroom D1
w1

2000 3930 2100

5 w4
D2
5 Client

Mr. ABDUL KADIR ISAHAK

1200 950 900 2280 900 1050 1200


Description
GROUND FLOOR PLAN
8480
Scale
A B C D E F G H Drawn By :
1:100

Checked By
WeBuildGHANA
0240020446 Drawing No.

Date
SEPTEMBER 2022


GROUND FLOOR PLAN


NOTES.
C1 THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
A B C D D1 E F G H TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.
8480
380
1200 950 520 630 1650 900 1050 1200 Recommended by
w1

1b 3530 4650
1b
w5
1650

1650

washroom Approved by
1500

2900

1a 1a
w5

D1
Lobby

2380 1000 Approved by


1400

1400
Laundry

w5
2050
w2

1 1
800

800

D2
3000 Granted by
2 DD
2
K. Store

2200
10000

10000

Signed by
3450

3450
Living Area
w4
6075

6000
Balcony

3 3
Kitchen

4450
1350

w2

1350

D2
Dining Area

Project
4 4 A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
1350

1350

D2 AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION


w3

5180 3000
1000
5 w4 w2
5 Client

Mr. ABDUL KADIR ISAHAK

1200 950 520 630 1650 900 1050 1200


Description
380
FIRST FLOOR PLAN
8480
Scale
A B C D D1 E F G H Drawn By :
1:100

Checked By
C1 WeBuildGHANA
0240020446 Drawing No.

Date
SEPTEMBER 2022


FIRST FLOOR PLAN


NOTES.
C1 THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
A B C D D1 E F G H TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.
8480
380
1200 950 520 630 1650 900 1050 1200 Recommended by
w1

1b 5180
1b
w5
1650

1650

Approved by
1800

Master
washroom
1a 1a
w5

D1
Approved by
1400

1400
walk in

w5

D2
Lobby
closet
1750

1 1
800

800

Granted by
2 DD
2
D2
10000

10000

Signed by
3450

3450
4850
Bedroom
w4

w4

w4
Master
Balcony
4725

Bedroom
6000

3 D2 3
1350

1350

D2
1000

Project
4 washroom
D1
closet 4 A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
1800
1350

1350

AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION


w3

3530 2500 2000

5 w4 w1
5 Client

Mr. ABDUL KADIR ISAHAK

1200 950 520 630 1650 900 1050 1200


Description
380
SECOND FLOOR PLAN
8480
Scale
A B C D D1 E F G H Drawn By :
1:100

Checked By
C1 WeBuildGHANA
0240020446 Drawing No.

Date
SEPTEMBER 2022


SECOND FLOOR PLAN


NOTES.
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.
C1
A B C D D1 E F G H
Recommended by
8480
900 8830
Approved by
1b 1b
600

150mm concrete slab


Fascia Board
Purlins @ 900mm c/c Approved by
1a 1a
3925

Rafters @ 1200mm c/c

fall 200mm Concrete Slab Granted by


1 1 1500mm Parapet Wall
2 2
100

Aluminum Roofing Sheet


600
150mm concrete slab

Signed by
10000

10000
10350
150mm concrete slab
6225

3 fall 3
Project
4 600 4 A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION

150mm concrete slab


600

5 5
100

Client

Mr. ABDUL KADIR ISAHAK


456 9274
Description
8480 ROOF PLAN

A B C D D1 E F G H Scale 1:100
C1 Drawn By : Checked By
WeBuildGHANA
0240020446 Drawing No.

Date
SEPTEMBER 2022

ROOF PLAN
Aluminum Roofing Sheet
50 x 50mmCeiling members @ 900mm
NOTES.
50 x 50mm Hangers @ 1050 c/c
50 x 150mm Rafters @ 1200 c/c THIS IS AN AUTO CAD GENERATED
50 x 75mm Purlins @ 1050 c/c DRAWING. ALL DIMENSION AND LEVELS
A 1b 100mm thickness Parapet cap TO BE CHECKED VERIFIED ON SITE BY
1500mm High Parapet wall THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.

Recommended by
3000

washroom Master
washroom

Approved by
3000

Dining Area Living room


See Engineering Drawings for Details
Approved by
3000

3600

Nook Granted by

H.C.F

Earth

Signed by
SECTIONAL VIEW

A H

Project
A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION
3000

Master Bedroom
Bedroom

Client

Mr. ABDUL KADIR ISAHAK


3000

Living room Kitchen


See Engineering Drawings for Details Description
SECTIONAL VIEWS

Scale 1:100
3000

Bedroom Bedroom Drawn By : Checked By


WeBuildGHANA
0240020446 Drawing No.
H.C.F H.C.F H.C.F
Date
Earth Earth Earth SEPTEMBER 2022

SECTIONAL VIEW
NOTES.
1b 5
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.

Recommended by

Approved by

Approved by

Granted by

FRONT VIEW
Signed by

5 1b

Project
A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION

Client

Mr. ABDUL KADIR ISAHAK

Description
FRONT & BACK VIEW

Scale 1:100

Drawn By : Checked By
WeBuildGHANA
0240020446 Drawing No.
BACK VIEW Date
SEPTEMBER 2022

NOTES.
H A
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.

Recommended by

Approved by

Approved by

Granted by

LEFT VIEW
Signed by

A H

Project
A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION

Client

Mr. ABDUL KADIR ISAHAK

Description
LEFT & RIGHT VIEW

Scale 1:100

Drawn By : Checked By
WeBuildGHANA
0240020446 Drawing No.
RIGHT VIEW Date
SEPTEMBER 2022

NOTES.
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
TO BE CHECKED VERIFIED ON SITE BY
THE CONTRACTOR PRIOR TO
COMMENCING ANY WORKS.

DOORS & WINDOWS SCHEDULE Recommended by

900 1800 1200 1800 Approved by


900

1200

1500

1500

Approved by

Granted by

CODE w1 w2 w3 w4
LOCATION Washroom and Master washroom Kitchen & Laundry Living room/Dining Area & Master Bedroom Living room, Bedroom & Master Bedroom
Signed by
NUMBER REQUIRED 5 4 2 9

400

750 900 1200


4800
2150

2150

2150

Project
A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING
AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION

CODE D1 D2 DD w5 Client
LOCATION Washroom and Master washroom Bedroom, Master Bedroom, Laundry Porch Staircase Mr. ABDUL KADIR ISAHAK
Lobby & Kitchen

NUMBER REQUIRED 5 13 3 3
Description
DOORS & WINDOWS SCHEDULES

Scale 1:100

Drawn By : Checked By
WeBuildGHANA
0240020446 Drawing No.

Date
SEPTEMBER 2022

NOTES.
THIS IS AN AUTO CAD GENERATED
DRAWING. ALL DIMENSION AND LEVELS
balloon cage to svp termination
above roof level TO BE CHECKED VERIFIED ON SITE BY
4-1602 THE CONTRACTOR PRIOR TO
01 01 COMMENCING ANY WORKS.

15-1001-175
soil and vent pipe
Recommended by
Fence Wall Elevation
3000

flushing cistern

cistern overflow pipe


Approved by
wc with 50mm
minimum seal 50mm dia. anti- syphonage pipe
Ground Plan
inspection eye

Approved by
floor fin.
5000 3000 4-1601
hardcore filling
2-12Ø 10 2 -12Ø
concrete
benching
225

450
to septic tank

Granted by
25 COVER
foundation concrete 150
2 - 12Ø 10 2 - 12Ø
450 BEAM / LINTEL SECTION 10 -10
300

Water Level

Signed by
750

1571

2550

2700

Water Level
1400
150

900
2700
1800
1800

1400

150

2100
866
150

SECTION b-b
SECTION a-a

Project
1200

A PROPOSED THREE (3) STOREY RESIDENTIAL BUILDING


AT PARKUSU - ASOKORE MAMPONG MUNICIPAL - ASHANTI REGION
150

1200

PLAN OF SOAKAWAY PIT


900

Client

Mr. ABDUL KADIR ISAHAK


150

750 150 Description


3000 1500 750 150
FENCE WALL, SEPTIC TANK, SOAKAWAY,
150 150
BEAM/LINTEL & COLUMN DETAILS
1800

750

4950
Scale 1:100
900
PLAN OF SEPTIC TANK SECTION c-c Drawn By : Checked By
SEPTIC TANK & SOAKAWAY SECTION d-d WeBuildGHANA
0240020446 Drawing No.

Date
SEPTEMBER 2022

STRUCTURES
NOTES.
A B C C1 D D1 E F G H
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,

F01 F01 F01 F01


WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


GRADE C20/40.

6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm

C01 C01 C01 C01


AT 28DAYS.
750 750

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
1500

VARIOUS AGGREGATES.

1b 1b 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

1c 1c
12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

750 750 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE

1500
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

1a 1a 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE

F02 F02 F02 F02 AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

1 1
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL

C02 C02 C02 C02


ENGINEER.

21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO


AS SHOWN IN THE TABLE (1) :

2 2 STRIP FOOTING
MINIMUM
COVER(mm)

-
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES

20 N/mm 1:3:6 0.11m3 0.21m3


VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)
VOLUME OF WATER
PER BAG OF CEMENT (L)

27.5 LITRES
0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE

F02 F02 F02 F02

C02 C02 C02 C02


3 3

4 F02 F02 F02 F02 4


1000

C02 C02 C02 C02 Project


PROPOSED RESIDENTIAL 2-STOREY
2000

5 5 BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
1000

ASHANTI REGION
Client

MR. ABDUL KADIR ISAHAK


1000 1000
2000 Description

FOUNDATION PLAN
Scale


A B C C1 D D1 E F G H Designed By

Drawn By
WEBUILD GH
Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.
+3.65 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS

50
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.
70 70
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL

500
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
+3.65
+3.65 WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
L=900

L=950

+0.50 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


50

+0.50
GRADE C20/40.

50
50

6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL


4R14-1

4R16-6
50

WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm


AT 28DAYS.
200 300

1610

1610
1550

1550

500
200 300

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE

500
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.

9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

±0.00 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
±0.00 REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL


COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
7R8-3-250

APPROVED.
1350

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE


9R8-4-175

CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED


L=1650

L=1650

1450

WITH.
L=1700

L=1700

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
2R14-2

2R14-2

2R16-7

2R16-7

15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
1200

1200

L=3150

L=3150
19R8-3-175
16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
L=3550

L=3550

OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR

3050
L=3550
HIS APPROVAL OR OTHERWISE.

2R14-4

2R14-4
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
2R14-1

2R14-1

COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE

6R14-1
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
13R8-2-250

2650
19R8-3-175

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.


3050

3050

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
350

70 70
250

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


-1.20 80 80 ENGINEER.

-1.20
2650

2650

21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO


AS SHOWN IN THE TABLE (1) :

A
125 200
3
MINIMUM
COVER(mm)
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES
VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)
VOLUME OF WATER
PER BAG OF CEMENT (L)

200
- 20 N/mm 1:3:6 0.11m3 0.21m3

125
STRIP FOOTING 0.55 27.5 LITRES
FOUNDATIONS-PAD

87.5
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES
250

175

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES

1b A
30 N/mm 1:2:4 3
200

200

25 0.07m 0.14m3 0.55 27.5 LITRES


120

120

87.5
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

200
200 . ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT

125125 L=8509R8-4-175
A2 - INNER BOTTOM REINFORCEMENT

125125 7R8-3-250 U1 - OUTER TOP REINFORCEMENT


(Hook:100)
250
U2 - INNER TOP REINFORCEMENT
L=1000 (Hook:100)
250
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
1C1 1C7
(250/250) (175/250)

3050

3050
+0.50
100

+0.50 200
100

+0.50
87.5
100

175

FOUNDATION R.C COLUMNS BENDING SCHEDULE D


120

120

A
2
87.5 200

SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) 125 200
200 125125 L=850
19R8-3-175
(Hook:100)
R8 0.395 130.6 51.6
125 87.5 250
175
250

1b E
120

120

87.5
200

200

R14 1.210 193.8 234.5 200


200
R16 1.580 10.6 16.8
125125 L=850
19R8-3-175 2C8
T.WEIGHT (Kg) 302.8 125125 13R8-2-250
L=1000 (Hook:100) 250
(Hook:100) (175/250)
250
NO SIZE QUA LENGTH (mm) TOTAL FORM

1 14 76 900 68.40 860 2C1 2C5


(250/250) (175/250)
70
2 14 76 1650 125.40 1550

Project
3 8 28 1000 28.00 200100 GROUND FLOOR R.C COLUMNS BENDING SCHEDULE
200 200 200 PROPOSED RESIDENTIAL 2-STOREY
SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) BUILDING TO BE BUILT AT
4 8 108 850 91.80 120
200
200100 120

R8 0.395 245.8 97.1 PARKUSU -ASOKORE MAMPONG MUNICIPALITY


5 8 18 600 10.80 120 80
100 120
80 ASHANTI REGION
R14 1.210 233.4 282.4
6 16 4 950 3.80 940
Client
T.WEIGHT (Kg) 379.5
MR. ABDUL KADIR ISAHAK
80
7 16 4 1700 6.80 1610

NO SIZE QUA LENGTH (mm) TOTAL FORM


Description
1 14 48 3550 170.40 3510

AS SHOWN
2 8 52 1000 52.00 200
200100
200 200
Scale

3 8 228 850 193.80 120
200
200100 120 Designed By
WEBUILD GH
70 Drawing No.
4 14 20 3150 63.00 3050
Drawn By
WEBUILD GH
Date SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL

875
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


GRADE C20/40.
+9.95 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

+6.80 WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm


50

AT 28DAYS.
70 70 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
50

1900 11R16-1-200 L=2700


OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE

11R16-1-200
L=2650
VARIOUS AGGREGATES.

2000
250
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)

11R16-2-200
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL


COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE

875
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
1900

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION

100
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR

912.5 175 912.5


HIS APPROVAL OR OTHERWISE.

2000 500 100


17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
L=3550

F02 2000 / 2000 (d = 500) 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
4R14-1

L=3150

L=3150
22R8-2-150

AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.


3150
3050
22R8-2-150

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


3150

ENGINEER.
2R14-1

2R14-1
3050

21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO


AS SHOWN IN THE TABLE (1) :

MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER


28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES
625

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
1400 9R16-3-200 L=2200 U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
L=2150

9R16-3-200
1500

HW - HARD WOOD
250

BM - BEAM
COL - COLUMN
9R16-4-200

G.A - GENERAL ARRANGEMENT


R.C. - REINFORCED CONCRETE
625
1400

100
3050

3050

+6.80 625 250 625


1500 500
100

+3.65 100
100

1b
75150
F01 1500 / 1500 (d = 500)
1b 200
75150 200 75
75 A
100

100

200
A
100

100

200

125125 22R8-2-150
L=800 (Hook:100)
125125 22R8-2-150
L=800 (Hook:100) 250
250
4C1
3C1 (150/250) PAD FOUNDATION BENDING SCHEDULE
(150/250) SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) Project
PROPOSED RESIDENTIAL 2-STOREY
R16 1.580 885.2 1,398.8
BUILDING TO BE BUILT AT
FIRST FLOOR R.C COLUMNS BENDING SCHEDULE SECOND FLOOR R.C COLUMNS BENDING SCHEDULE T.WEIGHT (Kg) 1,398.8 PARKUSU -ASOKORE MAMPONG MUNICIPALITY
SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) ASHANTI REGION
SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) NO SIZE QUA LENGTH (mm) TOTAL FORM
R8 0.395 281.6 111.2 Client
R8 0.395 246.4 97.3
1 16 132 2668 352.18 390 1900 390

R14 1.210 198.8 240.5


R14 1.210 201.6 243.9 MR. ABDUL KADIR ISAHAK
2 16 132 2636 347.95 370 1900 370
T.WEIGHT (Kg) 355.2
T.WEIGHT (Kg) 337.9 Description
3 16 43 2168 93.22 390 390

AS SHOWN
1400
NO SIZE QUA LENGTH (mm) TOTAL FORM
NO SIZE QUA LENGTH (mm) TOTAL FORM
4 16 43 2136 91.85 370
1400
370
70 Scale
1 14 56 3550 198.80 3510 1 14 64 3150 201.60 3050 
Designed By
2 8 308 800 246.40 100
200100
200 100 2 8 352 800 281.60 100
200100
200 100 WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,

A B C C1 D D1 E F G H
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


GRADE C20/40.

6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.

1C1 (250/250) 1C15 (250/250) 1C2 (250/250) 1C16 (250/250) 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

1b 1b
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL

1B25 150/300 1B26 150/300 1B27 150/300 REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL


COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

1c 1c
13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

1a 1a
1B12 150/300

1B20 150/300

1B24 150/300

1B21 150/300
16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

1 1 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


ENGINEER.

21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO


AS SHOWN IN THE TABLE (1) :

1C3 (175/250) 1C4 (175/250) 1C5 (175/250) 1C6 (175/250)

2 2
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

1B3 150/300 1B4 150/300 1B5 150/300 25


25
30 N/mm 1:2:4
30 N/mm 1:2:4
0.07m3 0.14m3
3
0.07m 0.14m3
0.55
0.55
27.5 LITRES
27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
1B13 150/300

1B17 150/300

1B18 150/300

1B22 150/300

1C7 (175/250) 1C8 (175/250) 1C9 (175/250) 1C10 (175/250)

3 1B6 150/300 1B7 150/300 1B8 150/300


3
1B16 150/300

1B19 150/300
1B14 150/300

1B23 150/300

4 4
Project
PROPOSED RESIDENTIAL 2-STOREY
1C11 (175/250) 1C12 (175/250) 1C13 (175/250) 1C14 (175/250) BUILDING TO BE BUILT AT

5 1B9 150/300 1B10 150/300 1B11 150/300


5 PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
Client

MR. ABDUL KADIR ISAHAK

A B C C1 D D1 E F G H
Description

G.A GROUND FLOOR PLAN


Scale

GROUND FLOOR - LEVEL: +0.5m - Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
A D E H 1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK

3050 2280 3150


MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

700
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

(2) 1 (2) 2 (2) 3 550 900 2R12-4(TT)


4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL

600
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

850 2R12-5(TT) 650 2R12-1(TT) 2R12-1(TT) 2R12-1(TT) 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.

2R12-1(TT) 600 2R12-4(TT) 500 2R12-6(TT) 2R12-7(TT) 17R8-3-175 17R8-3-175 17R8-3-175 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

1B3 1B4 1B5


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm

150/300 150/300 150/300 AT 28DAYS.

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE

300

300

300
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE

215
230
VARIOUS AGGREGATES.
17x1R8-3-175 13x1R8-3-175 18x1R8-3-175
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
2R12-2(BB) 2R12-2(BB) 2R12-2(BB) AND MUST COMPLY WITH B.S.12.

2R12-2(BB)
150 150 150 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL


(2) 1 (2) 2 (2) 3 (2) 1 - 1 (2) 2 - 2 (2) 3 - 3 COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

2875 87.5
87.5 2105 87.5
87.5 2975 87.5
87.5 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

A C F H
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

2150 4080 2250 2R14-9(TT)


16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
2R12-8(TT) 2R12-8(TT) 2R12-8(TT) HIS APPROVAL OR OTHERWISE.

(5) 1 (5) 2 (5) 3


1150 650 12R8-3-175 12R8-3-175 12R8-3-175 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN

650
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

600 1100 2R12-12(TT)

300

300

300
18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

2R12-8(TT) 500 2R14-9(TT) 2R12-10(TT) 600 550


2R14-11(TT) 19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS

1B9 150/300 1B10 150/300 1B11 150/300


AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


ENGINEER.
215 2R12-2(BB) 2R12-2(BB) 2R12-2(BB)
230
12x1R8-3-175 23x1R8-3-175 13x1R8-3-175
150 150 150 21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :

(5) 1 - 1 (5) 2 - 2 (5) 3 - 3


2R12-2(BB) MINIMUM
COVER(mm)
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES
VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)
VOLUME OF WATER
PER BAG OF CEMENT (L)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

30 N/mm 1:2:4 0.07m3 0.14m3 0.55

(5) 1 (5) 2 (5) 3


25 27.5 LITRES
25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

1975 87.5
87.5 3905 87.5
87.5 2075 87.5
87.5 . ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD

A D E H BM - BEAM
COL - COLUMN

3050 2280 3150


G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE

700 900
(3) 1 (3) 2 (3) 3 550 600 2R12-4(TT)
850 2R12-5(TT) 650 2R12-1(TT) 2R12-1(TT) 2R12-1(TT)
2R12-1(TT) 600 2R12-4(TT) 500 2R12-6(TT) 2R12-7(TT) 17R8-3-175 17R8-3-175 17R8-3-175
1B6 150/300 1B7 150/300 1B8 150/300
300

300

300
215

215
230

230

17x1R8-3-175 13x1R8-3-175 18x1R8-3-175

2R12-2(BB) 2R12-2(BB) 2R12-2(BB) 2R12-2(BB)


150 150 150
(3) 1 (3) 2 (3) 3
(3) 1 - 1 (3) 2 - 2 (3) 3 - 3
87.5
87.5 2875 87.5
87.5 2105 87.5
87.5 2975 87.5
87.5

5 3 5 3
2700 2700
Project
(F) 1 (F) 2 (F) 3 PROPOSED RESIDENTIAL 2-STOREY
(C) 1 (C) 2 (C) 3
2R12-19(TT)
2R12-19(TT) BUILDING TO BE BUILT AT
2R12-19(TT)
2R12-19(TT) PARKUSU -ASOKORE MAMPONG MUNICIPALITY
1B16 150/300
15R8-3-175 1B19 150/300
15R8-3-175

180180 180180 ASHANTI REGION


300
300

15x1R8-3-175 Client
15x1R8-3-175
MR. ABDUL KADIR ISAHAK
2R12-19(BB) 2R12-19(BB)
2R12-19(BB) 2R12-19(BB)
150 150 Description

(C) 1 (C) 2 (C) 3


(F) 1 (F) 2 (F) 3 GROUND FLOOR R.C COL. DET. 1/3
125125 2500 7575 (C) 1 - 1 125125 2500 7575 (F) 1 - 1
Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
5 3 2 1b 1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2700 3450 3850 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

1000 1100
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

(A) 1 (A) 2 (A) 3


650 600
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,

750 950
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF

600 600
GRADE C20/40.
2R12-13(TT) 2R12-15(TT) 2R12-16(TT) 2R14-17(TT) 2R12-18(TT)
1B14 150/300 1B13 150/300 1B12 150/300
6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm

180180 180180 AT 28DAYS.

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
15x1R8-3-175 19x1R8-3-175 21x1R8-3-175 VARIOUS AGGREGATES.

9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
2R12-14(BB)
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

(A) 1 (A) 2 (A) 3 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR

125125 2450 125125 3200 125125 3600 125125 APPROVED.

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE


CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
2R12-15(TT) WITH.

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


2R12-13(TT) 2R12-13(TT) 2R12-13(TT) HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

15R8-3-175 15R8-3-175 15R8-3-175 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
300

300

300

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
2R12-14(BB) 2R12-14(BB) 2R12-14(BB) COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE

150 150 150


AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS

(A) 1 - 1 (A) 2 - 2 (A) 3 - 3 AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


ENGINEER.

3 2 1b 21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO


AS SHOWN IN THE TABLE (1) :

3450 3850
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55

1100
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55

(E) 1 (E) 2 (E) 3


27.5 LITRES

600
25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

950 2R12-20(TT) 2R12-20(TT) 2R14-17(TT)


. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT

2R12-20(TT) 600 2R14-17(TT) 2R12-18(TT)


A2 - INNER BOTTOM REINFORCEMENT

1B18 1B24 19R8-3-175 19R8-3-175 19R8-3-175 U1 - OUTER TOP REINFORCEMENT

150/300 150/300 U2 - INNER TOP REINFORCEMENT

180180 180180 R - ROUND MILD STEEL REINFORCEMENT BAR


HW - HARD WOOD
BM - BEAM
300

300

300
COL - COLUMN
19x1R8-3-175 21x1R8-3-175 G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE

2R12-21(BB) 2R12-21(BB) 2R12-21(BB) 2R12-21(BB)


150 150 150
(E) 1 (E) 2 (E) 3

125125 3200 125125 3600 125125 (E) 1 - 1 (E) 2 - 2 (E) 3 - 3

A D E H
3050 2280 3150

(1b) 1 (1b) 2 (1b) 3 700 900


600
850 2R12-24(TT) 650
2R12-22(TT) 600 550
2R12-6(TT) 500 2R12-25(TT) 2R12-26(TT)
1B25 150/300 1B26 150/300 1B27 150/300
180180 180180
17x1R8-3-175 13x1R8-3-175 17x1R8-3-175

2R12-23(BB)
Project
(1b) 1 (1b) 2 (1b) 3 PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
125125 2800 125125 2030 125125 2900 125125 PARKUSU -ASOKORE MAMPONG MUNICIPALITY
2R12-6(TT) ASHANTI REGION
2R12-22(TT) 2R12-22(TT) 2R12-22(TT) Client
17R8-3-175 17R8-3-175 17R8-3-175
MR. ABDUL KADIR ISAHAK
300

300

300

Description
GROUND FLOOR R.C COL. DET. 2/3
2R12-23(BB) 2R12-23(BB) 2R12-23(BB)
Scale
150 150 150 
Designed By
WEBUILD GH
(1b) 1 - 1 (1b) 2 - 2 (1b) 3 - 3 Drawing No.
Drawn By
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK

3 2 1b
MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm

3450 3850
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

1100
4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
(D) 1 (D) 2 (D) 3
600 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF

950
GRADE C20/40.

2R12-20(TT) 2R12-20(TT) 2R14-17(TT) 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

600
WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
2R12-20(TT) 2R14-17(TT) 2R12-18(TT) AT 28DAYS.

1B17 150/300 1B20 150/300


19R8-3-175 19R8-3-175 19R8-3-175 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE

180180 180180 OPERATIONS.


8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.

300

300

300
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
19x1R8-3-175 21x1R8-3-175
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
2R12-21(BB) 2R12-21(BB) 2R12-21(BB) 2R12-21(BB) WORKS.

150 150 150 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
(D) 1 (D) 2 (D) 3
13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE

125125 3200 125125 3600 125125 (D) 1 - 1 (D) 2 - 2 (D) 3 - 3 CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

5 3 2 1b
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

2700 3450 3850 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

(H) 1 (H) 2 (H) 3


1000 1100 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN

650 600 COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE


AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

750 950 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
2R12-13(TT) 600 2R12-15(TT) 2R12-16(TT) 600 2R14-17(TT) 2R12-18(TT)
1B23 1B22 1B21
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS

150/300 150/300 150/300


AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

180180 180180 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.

15x1R8-3-175 19x1R8-3-175 21x1R8-3-175


21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :

2R12-14(BB) MINIMUM 28-DAY MIX-DESIGN VOL. OF FINE VOL. OF COARSE


WATER/CEMENT VOLUME OF WATER
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

(H) 1 (H) 2 (H) 3 25


25
30 N/mm 1:2:4
30 N/mm 1:2:4
0.07m3 0.14m3
3
0.07m 0.14m3
0.55
0.55
27.5 LITRES
27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3 0.5

125125 2450 125125 3200 125125 3600 125125


25 LITRES
1/2

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT

GROUND FLOOR R.C BEAMS BENDING SCHEDULE R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
2R12-15(TT) BM - BEAM

2R12-13(TT) 2R12-13(TT) 2R12-13(TT) SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
15R8-3-175 15R8-3-175 15R8-3-175 R8 0.395 349.4 138.0
R12 0.889 328.0 291.6
300

300

300

R14 1.210 22.9 27.7


T.WEIGHT (Kg) 457.3

2R12-14(BB) 2R12-14(BB) 2R12-14(BB) NO SIZE QUA LENGTH (mm) TOTAL FORM


150 150 150 1 12 4 3100 12.40 230
2860

(H) 1 - 1 (H) 2 - 2 (H) 3 - 3 2 12 6 9050 54.30 220


8590
220

100 100

3 8 411 850 349.35 230 230

100

4 12 4 1500 6.00 1460

5 12 4 2050 8.20 2040

6 12 6 1500 9.00 1490

2930
7 12 4 3200 12.80 230

2080
8 12 2 2350 4.70 230

9 14 2 1700 3.40 1690

10 12 2 3100 6.20 3080

11 14 2 1750 3.50 1710

12 12 2 2450 4.90
2180
230
Project
2620 PROPOSED RESIDENTIAL 2-STOREY
13 12 4 2800 11.20 180
BUILDING TO BE BUILT AT
14 12 4 10550 42.20 10180
180 180
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
15 12 4 1700 6.80 1700
ASHANTI REGION
16 12 4 2750 11.00 2730

Client
17 14 8 2000 16.00 1990

18 12 8 3700 29.60
3480
180
MR. ABDUL KADIR ISAHAK
2830
19 12 8 3250 26.00 180 220
Description
20 12 4 3400 13.60 180
3180
GROUND FLOOR R.C COL. DET. 3/3
21 12 4 7850 31.40 180
7480
180
Scale
22 12 2 3100 6.20
2880 
180
Designed By
23 12 2 9050 18.10 180
8660
180 WEBUILD GH
Drawn By Drawing No.
24 12 2 2000 4.00 1960
WEBUILD GH
25 12 2 1550 3.10 1530 SEPTEMBER 2022

26 12 2 3150 6.30
2950
180
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS

A B C C1 D D1 E F G H
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


GRADE C20/40.

6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.
2C1 (250/250) 2C16 (250/250)
3C15 (150/250) 2C2 (250/250) 2C15 (250/250) 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE

1b 1b
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.

2B1 150/500 2B32 150/500


2S11
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

d=175 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY

1c 1c
WORKS.

12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL


COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE


2B28 150/500

CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED


WITH.

1a 1a
14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
2B26 150/500

2B27 150/500

2B31 150/500
TENSILE AND OTHER RELEVANT TESTS.

2S1 2S2 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.
d=175 d=175
16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

1 2B24 150/500
1 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

2S3
20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL

2C3 (175/250) 2C4 (175/250)


3C16 (150/250) 2C5 (175/250) 2C6 (175/250) ENGINEER.

d=175
2 2
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :

2B29 150/500 2B3 150/500 2B4 150/500 2B5 150/500


MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
2B13 150/500

2B17 150/500

2B18 150/500

2B22 150/500

HW - HARD WOOD
2S4 2S5 2S6 BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
d=175 d=175 d=175 R.C. - REINFORCED CONCRETE

2C7 (175/250) 2C8 (175/250) 2C9 (175/250) 2C10 (175/250)


2S7

3 d=175
2B6 150/500 2B7 150/500 2B8 150/500
3
2B16 150/500

2B19 150/500
2B14 150/500

2B23 150/500

2S8 2S9 2S10


4 d=175 d=175 d=175 4

2C11 (175/250) 2C12 (175/250) 3C17 (150/250) 2C13 (175/250) 2C14 (175/250)
Project
5 2B25 150/500 2B9 150/500 2B10 150/500 2B11 150/500
5 PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
Client

A B C C1 D D1 E F G H MR. ABDUL KADIR ISAHAK


Description

G.A FIRST FLOOR PLAN


FIRST FLOOR - LEVEL: +3.65m - Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
A E H
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

5330 3150 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE

900
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
(1b) 1 (1b) 2 (1b) 3
650
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

1400 2R16-1(TT) 2R16-4(TT)


5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.

2R16-1(TT) 800 2R16-4(TT) 2R12-5(TT) 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

2B1 150/500 2B32 150/500 175


8R8-3-300
175
13R8-3-225 WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.

180 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
280

VARIOUS AGGREGATES.

180

500

500
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
280

8x1R8-3-300 13x1R8-3-225 11x1R8-3-300


2300 2700 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY

2R16-2(BB) 750 2R12-6(BB) 2R16-2(BB) 2R16-2(BB)


WORKS.

12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL

150 150
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

(1b) 1 (1b) 2 (1b) 3


3000 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
(1b) 1 - 1 (1b) 3 - 3 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT

125125 5080 125125 2900 125125 HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

A D E H 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS

3050 2280 3150 OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE

550 AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

700 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS

550
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

(3) 1 (3) 2 (3) 3 2R16-9(TT)


900 2R14-7(TT)
20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.

550 2R16-11(TT)
650
850 650
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
2R12-10(TB) AS SHOWN IN THE TABLE (1) :
2R14-7(TT) 2R12-10(TB)
2R14-7(TT) 700 2R16-9(TT) 500 2R14-12(TT) 2R12-13(TT)
2B6 150/500 2B7 150/500 2B8 150/500 175
11R8-3-300
175 175
11R8-3-300
175 STRIP FOOTING
FOUNDATIONS-PAD
MINIMUM
COVER(mm)

-
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES

20 N/mm 1:3:6 0.11m3 0.21m3


VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)

0.55
VOLUME OF WATER
PER BAG OF CEMENT (L)

27.5 LITRES

30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES


230

25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES
500

500
360

. ABBREVIATIONS
11x1R8-3-300 8x1R8-3-300 11x1R8-3-300 A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT

700
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
2R12-8(BB) 2R16-14(BB) 2R12-8(BB) 2R12-8(BB) BM - BEAM

150 150
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
(3) 1 (3) 2 (3) 3

2875 87.5
87.5 2105 87.5
87.5 2975 87.5
87.5 (3) 1 - 1 (3) 3 - 3

5 3 2 1b
2700 3450 3850

(A) 1 (A) 2 (A) 3


1000 1100
650 600
750 950
2R12-15(TT) 600 2R14-17(TT) 2R12-18(TT) 600 2R14-19(TT) 2R12-20(TT)
2B14 150/500 2B13 150/500 2B26 150/500
180 180
180 9x1R8-3-300 12x1R8-3-300 13x1R8-3-300
180

2R12-16(BB)

(A) 1 (A) 2 (A) 3

125125 2450 125125 3200 125125 3600 125125 Project


PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
2R14-17(TT)
ASHANTI REGION
2R12-15(TT) 2R12-15(TT)
9R8-3-300 9R8-3-300 Client
175 175 175 175
MR. ABDUL KADIR ISAHAK
500

500

Description
FIRST FLOOR R.C BEAMS DET. 1/4
Scale
2R12-16(BB) 2R12-16(BB) 
150 150 Designed By
WEBUILD GH
Drawn By Drawing No.
(A) 1 - 1 (A) 3 - 3 WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
5 3 5 3 1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

(C) 1 (C) 2 2700 (C) 3 (F) 1 (F) 2 2700 (F) 3 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS

2R12-21(TT) 2R12-21(TT) WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

2R12-21(TT) 2R12-21(TT) 3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE

2B16 150/500 175


9R8-3-300
175 2B19 150/500 175
9R8-3-300
175
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

180 180 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF

180 180
GRADE C20/40.
500

500
9x1R8-3-300 9x1R8-3-300 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.

2R12-21(BB) 2R12-21(BB) 2R12-21(BB) 2R12-21(BB) 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

150 150 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

(C) 1 (C) 2 (C) 3 (F) 1 (F) 2 (F) 3 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY

125125 2500 7575 (C) 1 - 1


125125 2500 7575 (F) 1 - 1 WORKS.

12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL


COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

3 2 1b 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE


CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

3450 3850 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE

700 TENSILE AND OTHER RELEVANT TESTS.

15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED

(D) 1 (D) 2 (D) 3 1100 FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

650 650 2R16-24(TT)


16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS

950 2R12-25(TB)
2R12-22(TT) 2R12-22(TT) 2R12-25(TB)
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

2R12-22(TT) 600 2R16-24(TT) 2R12-20(TT)


2B17 2B27 12R8-3-300 12R8-3-300 12R8-3-300 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN

180
150/500 150/500
180 175 175 175 175 175 175 COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
500

500

500
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
280

12x1R8-3-300 13x1R8-3-300
20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.

850
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :
2R14-23(BB) 2R16-26(BB) 2R14-23(BB) 2R14-23(BB) 2R14-23(BB)

3300 150 150 2R16-26(BB)


150
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

(D) 1 - 1 (D) 2 - 2 25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES

125
1125 3200 125125 3600 125125
25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
40 N/mm 1:1 :3 0.053m3 0.105m3 0.5

(D) (D) 2 (D) 3 (D) 3 - 3


25 25 LITRES
1/2

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT

3 2 1b
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR

3450 3850 HW - HARD WOOD


BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE

(E) 1 (E) 2 (E) 3


1100
650
950 2R12-22(TT) 2R12-22(TT) 2R16-24(TT)
2R12-22(TT) 600 2R16-24(TT) 2R12-20(TT)
2B18 150/500 2B28 150/500 175
12R8-3-300
175 175
12R8-3-300
175 175
12R8-3-300
175
180 180
500

500

500

12x1R8-3-300 13x1R8-3-300
220

2R14-27(BB) 2R14-27(BB) 2R14-27(BB) 2R14-27(BB)


150 150 150
(E) 1 (E) 2 (E) 3

125125 3200 125125 3600 125125 (E) 1 - 1 (E) 2 - 2 (E) 3 - 3

E H
(1) 1 (1) 2 3150 (1) 3

2R12-29(TT) 2R12-29(TT) 2R12-29(TT) Project


2R12-29(TT) PROPOSED RESIDENTIAL 2-STOREY
2B24 150/500 175
11R8-3-300
175
11R8-3-300
175
11R8-3-300
BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
250

ASHANTI REGION
500

500

500

11x1R8-3-300
250

Client

MR. ABDUL KADIR ISAHAK


2R12-29(BB) 2R12-29(BB) 2R12-29(BB) 2R12-29(BB)
7575 3000 7575 150 150 150 Description
(1) 1 (1) 2 (1) 3
FIRST FLOOR R.C BEAMS DET. 2/4
(1) 1 - 1 (1) 2 - 2 (1) 3 - 3
Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
5 3 2 1b
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2700 3450 3850 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

(H) 1 (H) 2 (H) 3


1000 1100 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL

650 600
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

750 950 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


GRADE C20/40.

2R12-15(TT) 600 2R12-28(TT) 2R12-18(TT) 600 2R14-19(TT) 2R12-20(TT) 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

2B23 2B22 2B31


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm

150/500 150/500 150/500 AT 28DAYS.

180 180 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.

180 9x1R8-3-300 12x1R8-3-300 13x1R8-3-300


180 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

2R12-16(BB) 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE


(H) 1 (H) 2 (H) 3 CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

125125 2450 125125 3200 125125 3600 125125 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
2R12-28(TT) STRUCTURAL ENGINEER.

2R12-15(TT) 2R12-15(TT) 2R12-15(TT) 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
9R8-3-300 9R8-3-300 9R8-3-300 OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR

175 175 175 HIS APPROVAL OR OTHERWISE.

17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
500

500

500

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


ENGINEER.
2R12-16(BB) 2R12-16(BB) 2R12-16(BB)
150 150 150 21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :

A C (H) 1 - 1 (H) 2 - 2 (H) 3 - 3


F H
1075 2150 4080 2250 STRIP FOOTING
FOUNDATIONS-PAD
/
MINIMUM
COVER(mm)

50
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES

20 N/mm 1:3:6 0.11m3 0.21m3

30 N/mm 1:2:4 3
0.07m 0.14m3
VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)

0.55

0.55
VOLUME OF WATER
PER BAG OF CEMENT (L)

27.5 LITRES

27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES

600
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

550 650 700


. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT

750
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT

1650 1150 550 U2 - INNER TOP REINFORCEMENT


R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD

3R16-33(TT) 750 700 3R16-40(TT)


BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
2R12-32(TB) 500 2R12-35(TB) 1100 2R14-39(TB) R.C. - REINFORCED CONCRETE

(5) 1 (5) 2 (5) 3 2R14-31(TT) 750 500 2R16-34(TT) 2R14-36(TT) 700 3R16-34(TT)
2B25 150/500 2B9 150/500 2B10 150/500 2B11 150/500
360
395
355

4x1R8-3-300 8x1R8-3-300 10x1R8-3-300 9x1R10-50-125 8x1R8-3-300


230

2850 1000

2R12-30(BB) 700 3R16-37(BB) 1100 2R12-41(BB)


2R14-38(BT) 2R16-34(BT)
(5) 1 (5) 2 (5) 3 700
700
2150
987.5 87.5
87.5 1975 87.5
87.5 3905 87.5
87.5 2075 87.5
87.5

2R14-31(TT) 2R14-31(TT) 2R14-31(TT)

2R12-32(TB) 2R12-32(TB) 2R12-32(TB)


Project
4R8-3-300 4R8-3-300 4R8-3-300
PROPOSED RESIDENTIAL 2-STOREY
175 175 175 BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
500

500

500

ASHANTI REGION
Client

2R12-30(BB) 2R12-30(BB) 2R12-30(BB) MR. ABDUL KADIR ISAHAK


150 150 150 Description

(5) 1 - 1 (5) 2 - 2 (5) 3 - 3 FIRST FLOOR R.C BEAMS DET. 3/4


Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
A D E H 1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK

1075 3050 2280 3150


MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

550
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

700 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,

600 WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

550
5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF

1650 900 GRADE C20/40.

650
6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

550 500
WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm

750 3R16-45(TT) AT 28DAYS.

850 650
7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
2R12-10(TB) 2R12-48(TB) OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE

(2) 1 (2) 2 (2) 3 2R14-31(TT) 2R16-43(TT) 700 2R16-9(TT) 500 2R14-12(TT) 2R12-13(TT)
VARIOUS AGGREGATES.

2B29 150/500 2B3 150/500 2B4 150/500 2B5 150/500


9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

230
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
395

WORKS.

4x1R8-3-300 11x1R8-3-300 6x1R10-50-150 5x1R8-3-300 11x1R8-3-300

230
750 1300 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE

850 700
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
2R12-42(BB) 2R16-46(BB) 2R12-49(BB)
700 R14-44(BT)
14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

(2) 1 (2) 2 (2) 3 2R12-47(BT)


15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE

700
STRUCTURAL ENGINEER.

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR

987.5 87.5
87.5 2875 87.5
87.5 2105 87.5
87.5 2975 87.5
87.5
HIS APPROVAL OR OTHERWISE.

17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.


2R14-31(TT) 2R14-31(TT) 2R14-31(TT) 19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
4R8-3-300 4R8-3-300 4R8-3-300
175 175 175 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.

21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO


AS SHOWN IN THE TABLE (1) :
500

500

500

MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER


28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES

2R12-42(BB) 2R12-42(BB) 2R12-42(BB) 25


25
30 N/mm 1:2:4 3
0.07m 0.14m3
40 N/mm 1:1 :3 0.053m3 0.105m3
0.55
0.5
27.5 LITRES

150 150 150


25 LITRES
1/2

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
(2) 1 - 1 (2) 2 - 2 (2) 3 - 3 U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
SIZE
NO

R16
R14
R12
R10
R8
50

49
48
47
46
45
44
43
42
41

40

39
38
37
36
35
34
33

32

31

30

29

28
27
26
25
24
23
22

21

20
19
18
17
16

15
14

13

12
11
10
9
8

6
5
4

2
1

FIRST FLOOR R.C BEAMS BENDING SCHEDULE


SIZE
10

12
12
12
16
16
14
16
12
12

16

14
14
16
14
12
16
16

12

14

12

12

12
14
16
12
16
14
12

12

12
14
12
14
12

12
16

12

14
16
12
16
12

14

12
12
16

16
16
8

UNIT WEIGHT (Kg/m)


QUA
270
15

2
2
2
2
3
1
2
2
2

2
2
3
2
2
7
3

2
2
2
2
4
2
4

8
4
4
2
4

4
2

4
2
4
4
2

2
2
2

2
2

LENGTH (mm)
10550

1.580
1.210
0.889
0.617
0.395
1250

3350
1100
1400
3650
2050
1500
2050
4000
2450

2550

1300
2700
5450
3300
1250
1750
1150

1950

3100

3100

3750

1700
7950
5050
1350
2000
3600
3400

3300

3700
2000
2750
1700

2800
4250

3200

1500
2050
1050
1500
5500

3250

3300
3150
2300

1250

6450
5100

T.WEIGHT (Kg)

LENGTH (m)
TOTAL
337.50
18.75

16.35

12.25

12.40

15.00

15.90
10.10

13.60

26.40

29.60

11.00

42.20

11.20

12.80

11.00

12.90
10.20

121.7

233.2

337.5
6.70
2.20
2.80
7.30
6.15
1.50
4.10
8.00
4.90

7.65

2.60
5.40

6.60
2.50

3.45

3.90

6.20

3.40

2.70
8.00
7.20

8.00

3.40

8.50

6.00
4.10
4.20
6.00

6.50

6.60
6.30
4.60

75.5

18.8

Project
PROPOSED RESIDENTIAL 2-STOREY
250

220

180

180

BUILDING TO BE BUILT AT
360

400

220

180

180

230

300

280

280

T.WEIGHT (Kg)
420

430

PARKUSU -ASOKORE MAMPONG MUNICIPALITY


FORM
3080

2180

2180

4770

3480

3890

2930

3080

2950
10180

ASHANTI REGION
1070

1400

3650

2030

1470

2010

3970

1270

2660

5450

3280

1210

1730

1110

3070

3230

1700

7480

1310

1990

2830

1990

2730

1700

1490

2040

1050

1470

2290

100

100
90

90

1570

2660

3380

3180

2620

5260

2950

6150

4790
420

120

430

100

Client
635.8
192.2

207.3

133.3
230

230

360

280

180

360

230

180

180

91.3

11.6
250

220

250

180

MR. ABDUL KADIR ISAHAK


Description
FIRST FLOOR R.C BEAMS DET. 4/4
Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK

A B C C1 D D1 E F G H
MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF

2C1 (250/250) 2C16 (250/250)


3C15 (150/250) 2C2 (250/250) 2C15 (250/250) GRADE C20/40.

1b 1b
6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
2S11 WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
100 100 100 AT 28DAYS.
5R12-5-150
L=800
L=850

L=800
L=1100
100

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


L=900

2B1 150/500 670 2B32 150/500


d=175 5R12-5-150 L=800 FIRST FLOOR R.C SLAB BENDING SCHEDULE OPERATIONS.
670
720

100
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
860
9R12-5-250

670 VARIOUS AGGREGATES.


12R12-14-250

20R12-26-150

20R12-25-150

5R12-19-150 L=3250 SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

1c 1c
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
100 AND MUST COMPLY WITH B.S.12.
15R12-2-250 L=850 15R12-4-250 L=2300 15R12-5-250 L=800 R12 0.889 1,375.4 1,222.6
100

100

730 15R12-1-250 L=3150 15R12-3-250 L=2400 670


11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY

T.WEIGHT (Kg) 1,222.6 WORKS.

12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL


2B28 150/500

COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR


APPROVED.
NO SIZE QUA LENGTH (mm) TOTAL FORM
1a 1a
13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
2B26 150/500

2B27 150/500

2B31 150/500

CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED


L=3950

L=3950

WITH.
2S1 2S2 1 12 37 3150 116.55 3150
14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
100 TENSILE AND OTHER RELEVANT TESTS.
12R12-13-250

9R12-13-250

d=175 d=175 2 12 15 850 12.75 730


15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE

3 12 37 2400 88.80 2380 STRUCTURAL ENGINEER.

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


4 12 37 2300 85.10 2270 OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
100
2S3 5 12 118 800 94.40
1 1
670
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
100 COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
L=800

3R12-20-250 L=650 3R12-5-250 L=800 6 12 35 2250 78.75 2250 AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
d=175
100

3R12-19-250
2B24 150/500
12R12-17-250 L=900

L=3250 670
670

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.


12R12-5-250

7 12 11 4200 46.20 4180


19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
2C3 (175/250) 2C4 (175/250)
3C16 (150/250) 2C5 (175/250) 2C6 (175/250)
L=2250

L=1800

L=2350

AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

8 12 20 2050 41.00
2 2
2040
20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
100 ENGINEER.
L=800

12R12-6-250

9R12-15-250

12R12-18-250

2B29 150/500 2B3 150/500 2B4 150/500 2B5 150/500 9 12 11 2350 25.85 2350
670

21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO


7R12-5-150

AS SHOWN IN THE TABLE (1) :


10 12 11 2100 23.10 2060

11 12 33 2800 92.40 2800


MINIMUM
COVER(mm)
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES
VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)
VOLUME OF WATER
PER BAG OF CEMENT (L)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD

12 12 33 3550 117.15 3550 30 N/mm 1:2:4 3


0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
40 N/mm 1:1 :3 0.053m3 0.105m3 0.5

13 12 21 3950 82.95
25 25 LITRES
1/2

3950
. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
2B13 150/500

2B17 150/500

2B18 150/500

2B22 150/500

100
L=3550

L=3550

L=3550

2S4 2S5 2S6 14 12 12 850 10.20 720


A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
15 12 9 1800 16.20 1790
12R12-12-250

9R12-12-250

12R12-12-250

d=175 d=175 d=175 HW - HARD WOOD


BM - BEAM
22R12-4-150 L=2300 22R12-23-150 L=850
100

COL - COLUMN
3490 22R12-22-150 L=3600 22R12-18-150 L=2350 750 16 12 12 2350 28.20 2310
G.A - GENERAL ARRANGEMENT
100

22R12-1-150 L=3150 22R12-19-150 L=3250 R.C. - REINFORCED CONCRETE

17 12 12 900 10.80 900


40R12-21-150 L=1100 22R12-3-150 L=2400
18 12 34 2350 79.90 2330
L=6250

19 12 30 3250 97.50 3250

2C7 (175/250) 2C8 (175/250) 2C9 (175/250) 2C10 (175/250) 20 12 3 650 1.95 640
7R12-24-150

L=2250

L=2050

L=2350

2S7
3 3 21 12 40 1100 44.00 1100

d=175
12R12-6-250

9R12-8-250

12R12-16-250

2B6 150/500 2B7 150/500 2B8 150/500 22 12 22 3600 79.20


100
3490

100
23 12 22 850 18.70 750

24 12 7 6250 43.75 6250


2B16 150/500

2B19 150/500
2B14 150/500

2B23 150/500
L=2800

16R12-11-250 L=2800

L=2800

2S8 2S9 2S10 25 12 20 900 18.00 860

4 4 26 12 20 1100 22.00 100 860 100


8R12-11-250

9R12-11-250

11R12-5-250 L=800 d=175 11R12-8-250 L=2050 d=175 11R12-10-250 L=2100 d=175 11R12-5-250 L=800
100

100

670 11R12-6-250 L=2250 11R12-7-250 L=4200 11R12-9-250 L=2350 670


L=800
L=800

L=800

L=800
680

2C11 (175/250) 2C12 (175/250) 3C17 (150/250) 2C13 (175/250) 2C14 (175/250)
670

670

670
16R12-5-250
7R12-5-150

8R12-5-250

9R12-5-250

5 100

2B25 150/500 2B9 150/500


100 100

2B10 150/500
100

2B11 150/500
5 Project
PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION

A B C C1 D D1 E F G H Client

MR. ABDUL KADIR ISAHAK


Description
FIRST FLOOR - LEVEL: +3.65m FOUNDATION PLAN
Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

A B C C1 D D1 E F G H
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


GRADE C20/40.

6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


3C1 (150/250) 3C15 (150/250) 3C2 (150/250) 3C4 (150/250) OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE

1b 3S19
1b
VARIOUS AGGREGATES.

9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

3B1 150/500 3B2 150/500


d=175 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

1c 1c
12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE


CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
3B28 150/500

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE

1a 1a
TENSILE AND OTHER RELEVANT TESTS.
3B26 150/500

3B32 150/500

3B6 150/500
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
3S11 FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

d=175 3S12
16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

d=175
17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

3S13
1 1
18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

d=175
3B24 150/500 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.

3C3 (150/250) 3C16 (150/250) 3C5 (150/250) 3C6 (150/250) 21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO

2 2
AS SHOWN IN THE TABLE (1) :

3B27 150/500 3B3 150/500 3B4 150/500 3B5 150/500 MINIMUM


COVER(mm)
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES
VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)
VOLUME OF WATER
PER BAG OF CEMENT (L)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
3B13 150/500

3B18 150/500

3B22 150/500

BM - BEAM
3S14 3S15 COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE

d=175 d=175

3S16

d=175
3C7 (150/250) 4C18 (150/250) 3C9 (150/250) 3C10 (150/250)

3 3B29 150/500 3B8 150/500


3

3S17
3B14 150/500

3B33 150/500

3B23 150/500

d=175 3S18
4 d=175 4

3C11 (150/250) 4C19 (150/250) 3C17 (150/250) 3C14 (150/250) Project


PROPOSED RESIDENTIAL 2-STOREY
5 3B25 150/500 3B30 150/500 3B31 150/500
5 BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
Client

MR. ABDUL KADIR ISAHAK


A B C C1 D D1 E F G H Description

G.A FIRST FLOOR PLAN


Scale
SECOND FLOOR - LEVEL: +6.80m 
Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND

A E H
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

5330 3150
2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

(1b) 1 (1b) 2 (1b) 3


900 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,

600 WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

1400
5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.
2R12-1(TT) 2R12-4(TT)
600
6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
2R12-1(TT) 2R12-4(TT) 2R12-5(TT) WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm

3B1 150/500 3B2 150/500 175


18R8-3-300
175
18R8-3-300 AT 28DAYS.

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.
250

250
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

500

500
320

18x1R8-3-300 11x1R8-3-300

250
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

2R14-2(BB) 700 2R12-6(BB) 2R14-2(BB) 2R14-2(BB)


12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR

150 150
APPROVED.

(1b) 1 (1b) 2 (1b) 3


3050 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

(1b) 1 - 1 (1b) 3 - 3 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT

7575 5180 7575 3000 7575


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS

5 3 2 1b
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

2700 3450 3850 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

(A) 1 (A) 2 (A) 3


1000 1100 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS

650 600 AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

750 950 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.

2R12-7(TT) 600 2R12-9(TT) 2R12-10(TT) 600 2R14-11(TT) 2R12-12(TT)


3B14 150/500 3B13 150/500 3B26 150/500 21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO

180 180
AS SHOWN IN THE TABLE (1) :

180
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55

9x1R8-3-300 12x1R8-3-300 13x1R8-3-300


FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3

220
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS

2R12-8(BB) 750 2R14-13(BB)


A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
(A) 1 (A) 2 (A) 3 BM - BEAM
COL - COLUMN

125125 2450 125125 3200 125125 3600 125125 G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE

2R12-9(TT)
2R12-7(TT) 2R12-7(TT) 2R12-7(TT)
9R8-3-300 9R8-3-300 9R8-3-300
175 175 175 175
500

500

500

2R12-8(BB) 2R12-8(BB) 2R12-8(BB)


150 150 150
5 3 (A) 1 - 1 (A) 2 - 2 (A) 3 - 3 2 1b
2700 3450 3850

(H) 1 (H) 2 (H) 3


1000 1100
650 600
750 950
2R12-7(TT) 600 2R12-9(TT) 2R12-10(TT) 600 2R12-15(TT) 2R12-12(TT)
3B23 150/500 3B22 150/500 3B6 150/500
180 180 Project
PROPOSED RESIDENTIAL 2-STOREY
180 9x1R8-3-300 12x1R8-3-300 13x1R8-3-300
180 BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
2R12-14(BB) 2R12-9(TT)
Client
2R12-7(TT) 2R12-7(TT) 2R12-7(TT)
(H) 1 (H) 2 (H) 3 9R8-3-300 9R8-3-300 9R8-3-300 MR. ABDUL KADIR ISAHAK
175 175 175
125125 2450 125125 125125 3600 125125 Description
SECOND FLOOR R.C BEAMS DET. 1/4
500

500

500

Scale

Designed By
2R12-14(BB) 2R12-14(BB) 2R12-14(BB) WEBUILD GH

150 150 150 Drawn By


WEBUILD GH
Drawing No.

SEPTEMBER 2022
(H) 1 - 1 (H) 2 - 2 (H) 3 - 3 CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND

E H
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK

2 1b
MEASURED AND REIMBURSED ACCORDINGLY.

(1) 1 (1) 2 3150 (1) 3


3850
2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

2R12-16(TT) 3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE

2R12-16(TT) OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

3B24 150/500 175


11R8-3-300 (D1) 1 (D1) 2 (D1) 3 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
2R12-35(TT) 2R12-35(TT) WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

2R12-35(TT) 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF

3B32 13R8-3-300 13R8-3-300 GRADE C20/40.


250

150/500 175 175 175 175


500

6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
11x1R8-3-300
250

AT 28DAYS.

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


OPERATIONS.

500

500
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.
13x1R8-3-300
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
2R12-16(BB) 2R12-16(BB)
7575 3000 7575 150
10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
(1) 1 (1) 2 (1) 3 3R16-36(BB) 3R16-36(BB) 3R16-36(BB) REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
(1) 1 - 1
2R12-37(BT) 150 2R12-37(BT) 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL

150
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

125125 3600 125125 (D1) 1 - 1 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
(D1) 1 (D1) 2 (D1) 3 CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
(D1) 2 - 2
14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

A E H 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE

1075 5330 3150


STRUCTURAL ENGINEER.

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR

900
HIS APPROVAL OR OTHERWISE.

1650 650 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE

1400 AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

(5) 1 (5) 2 (5) 3 2R12-18(TT) 650 2R12-20(TT) 600 2R16-23(TT) 2R12-5(TT) 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

3B25 150/500 3B30 150/500 3B31 150/500


19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


ENGINEER.

250
400

21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO


5x1R8-3-300 18x1R8-3-300 11x1R8-3-300

250
AS SHOWN IN THE TABLE (1) :

500 700
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55

2R12-17(BB) R12-19(BT) 2R16-21(BB) 2R12-6(BB)


FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3

700
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES

1650 2R12-22(BT)
3050
25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
(5) 1 (5) 2 (5) 3 A2 - INNER BOTTOM REINFORCEMENT

1000 7575 5180 7575 3000 7575


U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
2R12-18(TT) 2R12-18(TT) 2R12-18(TT) COL - COLUMN
G.A - GENERAL ARRANGEMENT
5R8-3-300 5R8-3-300 5R8-3-300 R.C. - REINFORCED CONCRETE
500

500

500

2R16-23(TT)

2R14-30(TT) 2R14-30(TT) 2R16-33(TB)


18R8-3-300 18R8-3-300 18R8-3-300
2R12-17(BB) 2R12-17(BB) 2R12-17(BB) 175 175 175 175 175 175
150 150 2R16-21(BB)
R12-19(BT)
500

500

500

(5) 1 - 1 (5) 2 - 2 150


(5) 3 - 3

4R16-31(BB) 4R16-31(BB) 4R16-31(BB)


150 2R14-32(BT) 150
150
(3) 1 - 1 (3) 3 - 3
(3) 2 - 2
A E H
5330 3150
650 Project
(3) 1 (3) 2 (3) 3 900 PROPOSED RESIDENTIAL 2-STOREY
900 800 BUILDING TO BE BUILT AT
1400 2R16-33(TB) PARKUSU -ASOKORE MAMPONG MUNICIPALITY
2R14-30(TT) 700 2R16-23(TT) 3R16-34(TT) ASHANTI REGION
3B29 150/500 3B8 150/500
Client

MR. ABDUL KADIR ISAHAK


320

380
380

18x1R8-3-300 11x1R8-3-300
250

Description
SECOND FLOOR R.C BEAMS DET. 2/4
4R16-31(BB) 700 2R12-6(BB)
Scale

2R14-32(BT)
3050 Designed By
WEBUILD GH
(3) 1 (3) 2 (3) 3 Drawing No.
7575 5180 7575 3000 7575 Drawn By
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
A D1 E H
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

1075 3680 1650 3150 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

1650 650 900 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL

650 650
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

1000 2R14-27(TT) 500 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.

(2) 1 (2) 2 (2) 3 2R12-18(TT) 2R12-24(TT) 600 550


2R16-26(TT) 400 2R12-29(TT) 2R12-5(TT) 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

3B27 150/500 3B3 3B4 3B5


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm

150/500 150/500 150/500 AT 28DAYS.

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE

250250
VARIOUS AGGREGATES.
400

9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

5x1R8-3-300 13x1R8-3-300 6x1R8-3-300 11x1R8-3-300 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY

700
WORKS.

2R12-17(BB) 2R16-25(BB) 2R12-28(BB) 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

(2) 1 (2) 2 (2) 3


700 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED

1550 WITH.

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

1000 7575 3530 7575 1500 7575 3000 7575 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
2R12-18(TT) 2R12-18(TT) 2R12-18(TT)
5R8-3-300 5R8-3-300 5R8-3-300 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN

175 175 175 COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
500

500

500

AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


ENGINEER.

21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO


AS SHOWN IN THE TABLE (1) :
2R12-17(BB) 2R12-17(BB) 2R12-17(BB)
150 150 2R16-25(BB)
150
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

(2) 1 - 1 (2) 2 - 2 25 30 N/mm 1:2:4 0.07m3 0.14m3


3
0.55 27.5 LITRES
25 30 N/mm 1:2:4 0.07m 0.14m3 0.55 27.5 LITRES

5 3 (2) 3 - 3
2 1b
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS

2700 3450 3850 A1 - OUTER BOTTOM REINFORCEMENT


A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR

1000 1100
HW - HARD WOOD
BM - BEAM
(E) 1 (E) 2 (E) 3 COL - COLUMN

650 650 G.A - GENERAL ARRANGEMENT

750 950
R.C. - REINFORCED CONCRETE

2R12-7(TT) 600 2R16-38(TT) 2R12-10(TT) 600 2R16-39(TT) 2R12-12(TT)


3B33 150/500 3B18 150/500 3B28 150/500
180 180
180 9x1R8-3-300 12x1R8-3-300 13x1R8-3-300
180

2R12-14(BB)

(E) 1 (E) 2 (E) 3

125125 2450 125125 3200 125125 3600 125125

2R16-38(TT)
2R12-7(TT) 2R12-7(TT) 2R12-7(TT)
9R8-3-300 9R8-3-300 9R8-3-300
175 175 175 175 175 175
Project
500

500

500

PROPOSED RESIDENTIAL 2-STOREY


BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
2R12-14(BB) 2R12-14(BB) 2R12-14(BB)
ASHANTI REGION
150 150 150 Client

(E) 1 - 1 (E) 2 - 2 (E) 3 - 3 MR. ABDUL KADIR ISAHAK


Description
SECOND FLOOR R.C BEAMS DET. 3/4
Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

FIRST FLOOR R.C BEAMS BENDING SCHEDULE 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.

R8 0.395 316.3 124.9 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL
WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.
R12 0.889 253.0 224.9 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
R14 1.210 46.7 56.5 8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.

R16 1.580 96.2 152.0 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
T.WEIGHT (Kg) 558.3 AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
NO SIZE QUA LENGTH (mm) TOTAL FORM WORKS.

12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL


4560
1 12 2 4850 9.70 250
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

2 14 2 6400 12.80 320


6050 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.
100 100
14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
3 8 253 1250 316.25 430 430 HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
100
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED

4 12 2 2250 4.50 2240 FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

2930
5 12 6 3200 19.20 250 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
6 12 6 3350 20.10 3080
250 HIS APPROVAL OR OTHERWISE.

2620
7 12 6 2800 16.80 180 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.
8 12 2 6300 12.60 180
6080

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.


9 12 4 1700 6.80 1700
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
10 12 6 2750 16.50 2730

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


11 14 2 2000 4.00 1990
ENGINEER.

3480
12 12 6 3700 22.20 180
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :

13 14 2 4900 9.80 4670


220

14 12 4 10550 42.20 180


10180
180 MINIMUM
COVER(mm)
28-DAY
STRENGHT
MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES
VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)
VOLUME OF WATER
PER BAG OF CEMENT (L)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD

15 12 2 2000 4.00
30 N/mm 1:2:4 3
0.07m 0.14m3
1990 / 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
3230
16 12 4 3750 15.00 25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES
250 250
. ABBREVIATIONS
17 12 4 950 3.80 930 A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
2650 U1 - OUTER TOP REINFORCEMENT
18 12 4 3050 12.20 400
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
19 12 1 2100 2.10 2090 BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
20 12 2 3550 7.10 3510
R.C. - REINFORCED CONCRETE

21 16 2 6700 13.40 6690

22 12 2 3600 7.20 3560

23 16 4 2250 9.00 2240

24 12 2 2300 4.60 2280

25 16 2 5050 10.10 5040

26 16 2 1600 3.20 1600

27 14 2 1450 2.90 1430

28 12 2 5000 10.00 4730


250

29 12 2 1350 2.70 1340

4660
30 14 2 5000 10.00 320

31 16 4 6450 25.80 380


6050

32 14 2 3600 7.20 3560

33 16 2 1500 3.00 1500

3080
34 16 3 3500 10.50 380

4030
35 12 2 4400 8.80 180 180

36 16 3 4600 13.80 280


4030
280

37 12 2 2450 4.90 2450

38 16 2 1700 3.40 1700


Project
39 16 2 2000 4.00 1990
PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
Client

MR. ABDUL KADIR ISAHAK


Description
SECOND FLOOR R.C BEAMS DET. 4/4
Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm

I A B C C1 D D1 E F G H
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


GRADE C20/40.

6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

3C1 (150/250) 3C15 (150/250) 3C2 (150/250) 3C4 (150/250) WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.

1b 3S19
1b
7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
100 100 100
L=800

8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
L=1100
L=950

VARIOUS AGGREGATES.
L=900

3B1 150/500 3B2 150/500


d=175
670

9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.
810

860

5R12-14-150
10R12-5-150

L=650
23R12-19-150

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
20R12-25-150

20R12-24-150

5R12-9-150 L=3250 5R12-5-150 L=800 AND MUST COMPLY WITH B.S.12.


100

670

1c 1c
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
100 REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
25R12-2-150 L=950 25R12-4-150 L=2650 25R12-5-150 L=800 WORKS.
100

100

830 25R12-1-150 L=3800 25R12-3-150 L=1750 670 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.
3B28 150/500

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE


CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED

SECOND FLOOR R.C SLAB BENDING SCHEDULE WITH.

1a 1a 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


3B26 150/500

3B32 150/500

3B6 150/500
L=3950

L=3950

HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
3S11 SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg)
TENSILE AND OTHER RELEVANT TESTS.

15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
23R12-17-150

10R12-17-150

d=175 3S12 R12 0.889 1,763.0 1,567.1 STRUCTURAL ENGINEER.

T.WEIGHT (Kg) 1,567.1 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION

d=175 OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

NO SIZE QUA LENGTH (mm) TOTAL FORM 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
3S13
1 1
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

100
1 12 25 3800 95.00 3780
L=800

18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

4R12-14-150 d=175
3B24 150/500
20R12-21-150 L=900

L=650 4R12-5-150 L=800 2 12 25 950 23.75


100
19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
670
L=750

100

4R12-9-150 L=3250 670


830 AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
20R12-5-150

3C3 (150/250) 3C16 (150/250) 3C5 (150/250) 3C6 (150/250) 3 12 25 1750 43.75 1750
L=2650

L=2350

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


10R12-23-150

ENGINEER.

2 2 4 12 25 2650 66.25 2650


21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
23R12-18-150

20R12-22-150

AS SHOWN IN THE TABLE (1) :

3B27 150/500 3B3 150/500 3B4 150/500 3B5 150/500 100


5 12 135 800 108.00 670
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT

6 12 31 1100 34.10
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

1100 STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 0.55 27.5 LITRES
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55

7 12 39 5450 212.55
27.5 LITRES
5430 25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

100 . ABBREVIATIONS
8 12 22 4000 88.00 3870
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
9 12 48 3250 156.00
3B13 150/500

3B18 150/500

3B22 150/500

3250 U2 - INNER TOP REINFORCEMENT


L=3550
L=3550

3S14 3S15 R - ROUND MILD STEEL REINFORCEMENT BAR


HW - HARD WOOD
10 12 56 2550 142.80 2510 BM - BEAM
COL - COLUMN
34R12-16-150

20R12-16-150

d=175 d=175 G.A - GENERAL ARRANGEMENT


22R12-10-150 L=2550 11 12 22 850 18.70
100
750
R.C. - REINFORCED CONCRETE

3870 22R12-8-150 L=4000 22R12-11-150 L=850


100

100

22R12-7-150 L=5450 750 12 12 17 1050 17.85 1050

31R12-6-150 L=1100 22R12-9-150 L=3250


3S16 13 12 17 2050 34.85 2040

14 12 9 650 5.85 640


d=175
15 12 54 2800 151.20 2800
3C7 (150/250) 4C18 (150/250) 3C9 (150/250) 3C10 (150/250)
L=2550

L=2350

3 3 16 12 54 3550 191.70 3550


34R12-10-150

20R12-20-150

3B29 150/500 3B8 150/500 17 12 33 3950 130.35 3950

18 12 23 2650 60.95 2630


17R12-12-150 L=1050 17R12-13-150 L=2050 17R12-5-150 L=800
100

17R12-7-150 L=5450 17R12-9-150 L=3250 670 100


19 12 23 950 21.85
3S17 810

20 12 20 2350 47.00 2310


3B14 150/500

3B33 150/500

3B23 150/500
34R12-15-150 L=2800

20R12-15-150 L=2800

d=175 3S18
4 d=175 4 21
22
12
12
20
20
900
2350
18.00
47.00
900

2330

23 12 10 750 7.50 730

24 12 20 900 18.00 860


L=800

L=800

25 12 20 1100 22.00 100 860 100


680

680

3C11 (150/250) 4C19 (150/250) 3C17 (150/250) 3C14 (150/250)


34R12-5-150

20R12-5-150

5 3B25 150/500
100

3B30 150/500
100

3B31 150/500
5 Project
PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
Client

I A B C C1 D D1 E F G H MR. ABDUL KADIR ISAHAK


Description

SECOND FLOOR R.C SLAB DET.


SECOND FLOOR - LEVEL: +6.80m
Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

A B C C1 D D1 E F G H
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


GRADE C20/40.

6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.

4C1 (150/250) 4C15 (150/250) 4C2 (150/250) 4C4 (150/250) 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.

1b 1b
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.

9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

4B1 150/350 4B2 150/500 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

1c 1c 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL


COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE


CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
4B28 150/350

WITH.

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE

1a 1a
TENSILE AND OTHER RELEVANT TESTS.
4B26 150/350

4B32 150/350

4B3 150/500
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

1 1
18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

4B24 150/350
20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.

4C3 (150/250) 4C16 (150/250) 4C5 (150/250) 4C6 (150/250)

2 2
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :

4B34 150/350 4B35 150/350 4B36 150/350 4B5 150/350 MINIMUM 28-DAY MIX-DESIGN VOL. OF FINE VOL. OF COARSE
WATER/CEMENT VOLUME OF WATER
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
4B38 150/350

4B13 150/350

4B40 150/350

4B18 150/350

4B22 150/350

BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE

4C7 (150/250) 4C18 (150/250) 4C9 (150/250) 4C10 (150/250)

3 4B37 150/350 4B29 150/350 4B8 150/350


3
4B39 150/350

4B14 150/350

4B41 150/350

4B33 150/350

4B23 150/350

4 4

4C11 (150/250) 4C19 (150/250) 4C17 (150/250) 4C14 (150/250) Project

5 4B25 150/350 4B30 150/350 4B31 150/350


5 PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
Client

MR. ABDUL KADIR ISAHAK


A B C C1 D D1 E F G H Description

G.A ROOF BEAMS


ROOF BEAMS - LEVEL: +9.95m Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
Date SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
A E H 1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

5330 (1b) 4 (1b) 5 3150 (1b) 6 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS

(1b) 1 (1b) 2 (1b) 3


900 WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

600
3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

1400 2R12-1(TT) 2R12-1(TT) 2R12-4(TT)


4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,

600
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
2R12-1(TT) 2R12-4(TT) 2R12-5(TT)
4B1 4B2 24R8-3-225 24R8-3-225 24R8-3-225 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF

150/350 150/500 GRADE C20/40.

6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.

250

350

350

350
7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
24x1R8-3-225 OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
11x1R8-7-300
250

VARIOUS AGGREGATES.

9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

2R12-2(BB) 2R12-6(BB) 2R12-2(BB) 2R12-2(BB) 2R12-2(BB) 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)

300 150 150 150


AND MUST COMPLY WITH B.S.12.

11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
(1b) 1 (1b) 2 (1b) 3 WORKS.

(1b) 1 - 1 (1b) 2 - 2 (1b) 3 - 3 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
(1b) 4 (1b) 5 (1b) 6 COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

5180 7575 3000 7575 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED

5 3 2 1b
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

2700 3450 3850 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS

1000 1100
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.

(A) 1 (A) 2 (A) 3


650 600 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN

750 950
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

2R12-8(TT) 600 2R12-10(TT) 2R12-11(TT) 600 2R12-12(TT) 2R12-13(TT) 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

4B14 150/350 4B13 150/350 4B26 150/350 19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS

180 180 AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

180 180 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL
ENGINEER.
12x1R8-3-225 15x1R8-3-225 17x1R8-3-225
21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :

2R12-9(BB)
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

(A) 1 (A) 2 (A) 3 25


25
30 N/mm 1:2:4
30 N/mm 1:2:4
0.07m3 0.14m3
3
0.55
0.55
27.5 LITRES
0.07m 0.14m3 27.5 LITRES

125125 2450 125125 3200 125125 3600 125125


25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
2R12-10(TT) U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
2R12-8(TT) 2R12-8(TT) 2R12-8(TT) R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
12R8-3-225 12R8-3-225 12R8-3-225 BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
350

350

350

2R12-9(BB) 2R12-9(BB) 2R12-9(BB)


150 150 150
(A) 1 - 1 (A) 2 - 2 (A) 3 - 3
5 3 2 1b
2700 3450 (H) 4 (H) 5 3850 (H) 6

(H) 1 (H) 2 (H) 3


1000 1100
650 600
750 950
2R12-8(TT) 600 2R12-10(TT) 2R12-11(TT) 600 2R12-12(TT) 2R12-13(TT)
4B23 150/350 4B22 150/350 4B3 150/500
180 180
180
12x1R8-3-225 15x1R8-3-225
180 13x1R8-7-300

2R12-14(BB) 2R12-15(BB)
250
(H) 1 (H) 2 (H) 3
Project
(H) 4 (H) 5 (H) 6
PROPOSED RESIDENTIAL 2-STOREY
125125 2450 125125 3200 125125 3600 125125 BUILDING TO BE BUILT AT
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
2R12-10(TT) Client
2R12-8(TT) 2R12-8(TT) 2R12-8(TT)
12R8-3-225 12R8-3-225 12R8-3-225 MR. ABDUL KADIR ISAHAK
Description

ROOF R.C BEAMS DET. 1/4


350

350

350

Scale

2R12-14(BB) 2R12-14(BB) 2R12-14(BB) Designed By
150 150 150 Drawn By
WEBUILD GH
Drawing No.
WEBUILD GH
(H) 1 - 1 (H) 2 - 2 (H) 3 - 3 SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
E H
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

(1) 1 (1) 2 3150 (1) 3


2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

2R12-6(TT) 3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
2R12-6(TT) OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

4B24 150/350
14R8-3-225 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


GRADE C20/40.
250
250

350

14x1R8-3-225 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL


WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


OPERATIONS.
2R12-6(BB) 2R12-6(BB) 8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.

7575 3000 7575 150 9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

(1) 1 (1) 2 (1) 3 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

(1) 1 - 1 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

A E H
12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

1075 5330 3150 13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE
CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

900 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT

1750 600
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

1400 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE

650 600
STRUCTURAL ENGINEER.
(5) 1 (5) 2 (5) 3 2R12-17(TT) 2R12-18(TT) 2R12-20(TT) 2R12-5(TT)
4B25 150/350 4B30 150/350 4B31 150/350 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
HIS APPROVAL OR OTHERWISE.
250

250
6x1R8-3-225 24x1R8-3-225 14x1R8-3-225 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

2R12-16(BB) 700 2R14-19(BB) 700 2R12-21(BB)


18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

50 3050 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL

1000
ENGINEER.

21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO


AS SHOWN IN THE TABLE (1) :

(5) 1 (5) 2 1000(5) 3 7575 5180 7575 3000 7575 MINIMUM


COVER(mm)
28-DAY MIX-DESIGN
RATIO
VOL. OF FINE
AGGREGATES
VOL. OF COARSE
AGGREGATES
WATER/CEMENT
RATIO (BY WEIGHT)
VOLUME OF WATER
PER BAG OF CEMENT (L)
STRENGHT

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD

2R12-17(TT) 2R12-17(TT) 2R12-17(TT) 30 N/mm 1:2:4 3


0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES

6R8-3-225 6R8-3-225 6R8-3-225


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

. ABBREVIATIONS
A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
350

350

350

U1 - OUTER TOP REINFORCEMENT


U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
COL - COLUMN
G.A - GENERAL ARRANGEMENT
2R12-16(BB) 2R12-16(BB) 2R12-16(BB) R.C. - REINFORCED CONCRETE

150 150 2R14-19(BB)


150
5 3 (5) 1 - 1 (5) 2 - 2
2 1b
2700 3450 (5) 3 - 3
3850
(E) 1 (E) 2 (E) 3
1000 1100
650 600
750 950
2R12-8(TT) 600 2R12-10(TT) 2R12-11(TT) 600 2R12-12(TT) 2R12-13(TT)
4B33 150/350 4B18 150/350 4B28 150/350
180 180
180 180
12x1R8-3-225 15x1R8-3-225 17x1R8-3-225

2R12-9(BB)

(E) 1 (E) 2 (E) 3

125125 2450 125125 3200 125125 3600 125125


2R12-10(TT)
2R12-8(TT) 2R12-8(TT) 2R12-8(TT)
12R8-3-225 12R8-3-225 12R8-3-225 Project
PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
350

350

350

PARKUSU -ASOKORE MAMPONG MUNICIPALITY


ASHANTI REGION

2R12-9(BB) 2R12-9(BB) 2R12-9(BB) Client

150 150 150 MR. ABDUL KADIR ISAHAK


(E) 1 - 1 (E) 2 - 2 (E) 3 - 3
Description

ROOF R.C BEAMS DET. 2/4


Scale

Designed By
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND

A D1 E H
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

1075 3680 1650 3150


2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

1750 550 900


3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

650 400 600


4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,

1000 500
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.
2R12-25(TT) 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF
GRADE C20/40.

(2) 1 (2) 2 (2) 3 2R12-17(TT) 2R12-23(TT) 600 2R12-24(TT) 400 2R12-26(TT) 2R12-5(TT)
4B34 4B35 4B36 4B5
6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

150/350 150/350 150/350 150/350 WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm
AT 28DAYS.

7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE


OPERATIONS.
250

250
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
VARIOUS AGGREGATES.
6x1R8-3-225 17x1R8-3-225 8x1R8-3-225 14x1R8-3-225
9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

2R12-22(BB) 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

50 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL


COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
APPROVED.

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE

(2) 1 (2) 2 1000(2) 3 7575 3530 7575 1500 7575 3000 7575 CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT


HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.

2R12-17(TT) 2R12-17(TT) 2R12-17(TT) 15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
6R8-3-225 6R8-3-225 6R8-3-225 STRUCTURAL ENGINEER.

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
350

350

350

HIS APPROVAL OR OTHERWISE.

17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

2R12-22(BB) 2R12-22(BB) 2R12-22(BB) 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

150 150 150 19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL

A (2) 1 - 1 (2) 2 - 2 (2) 3 - 3


E H
ENGINEER.

1075 5330 3150


21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :

900
1750 650
MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55

1400
FOUNDATIONS-PAD
30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES

650 600
25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES

(3) 1 (3) 2 (3) 3 2R16-27(TT) 2R12-18(TT) 2R16-30(TT) 2R12-5(TT) 25 40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.5 25 LITRES

4B37 150/350 4B29 150/350 4B8 150/350 . ABBREVIATIONS


A1 - OUTER BOTTOM REINFORCEMENT
A2 - INNER BOTTOM REINFORCEMENT
U1 - OUTER TOP REINFORCEMENT

250
250

250
U2 - INNER TOP REINFORCEMENT
6x1R8-3-225 24x1R8-3-225 14x1R8-3-225 R - ROUND MILD STEEL REINFORCEMENT BAR
HW - HARD WOOD
BM - BEAM
COL - COLUMN

700 700
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
2R12-16(BB) 2R16-28(BB) 2R12-21(BB)

50 2R12-29(BT)
3050
1000
(3) 1 (3) 2 1000(3) 3 7575 5180 7575 3000 7575
2R16-27(TT) 2R16-27(TT) 2R16-27(TT)
6R8-3-225 6R8-3-225 6R8-3-225
350

350

350

2R12-16(BB) 2R12-16(BB) 2R12-16(BB)


150 150 2R16-28(BB)
150
(3) 1 - 1 (3) 2 - 2
(3) 3 - 3

5 3 2 Project
2700 3450 PROPOSED RESIDENTIAL 2-STOREY
BUILDING TO BE BUILT AT
(I) 1 (I) 2 (I) 3
950 PARKUSU -ASOKORE MAMPONG MUNICIPALITY
600 2R12-33(TT)
ASHANTI REGION
750 2R12-31(TT) 2R12-31(TT) 2R12-31(TT)
2R12-31(TT) 600 2R12-33(TT) 2R12-34(TT)
4B39 4B38 12R8-3-225 12R8-3-225 12R8-3-225 Client
150/350 150/350
MR. ABDUL KADIR ISAHAK
250

250
250

250

350

350

350

12x1R8-3-225 16x1R8-3-225
Description

ROOF R.C BEAMS DET. 3/4


2R12-32(BB) 2R12-32(BB) 2R12-32(BB) 2R12-32(BB)
7575 2550 7575 3300 7575 150 150 150 Scale

(I) 1 (I) 2 (I) 3 Designed By
(I) 1 - 1 (I) 2 - 2 (I) 3 - 3 WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND

5 3 2 1b
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

2700 3450 3850


2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm
GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

(D1) 1 (D1) 2 (D1) 3


1000 1100 3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE
OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

650 600 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL

750 950
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


2R12-8(TT) 600 2R12-10(TT) 2R12-11(TT) 600 2R12-12(TT) 2R12-13(TT) GRADE C20/40.

4B41 150/350 4B40 150/350 4B32 150/350 6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

180 180 WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm


AT 28DAYS.

180 180 7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
12x1R8-3-225 15x1R8-3-225 17x1R8-3-225 VARIOUS AGGREGATES.

9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.
2R12-9(BB)
11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.

(D1) 1 (D1) 2 (D1) 3 12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL
COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR

125125 2450 125125 3200 125125 3600 125125


APPROVED.

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE


CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED
WITH.

2R12-10(TT) 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
2R12-8(TT) 2R12-8(TT) 2R12-8(TT)
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
12R8-3-225 12R8-3-225 12R8-3-225 FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
STRUCTURAL ENGINEER.

16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION


OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
350

350

350

OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR

ROOF R.C BEAMS BENDING SCHEDULE HIS APPROVAL OR OTHERWISE.

SIZE UNIT WEIGHT (Kg/m) LENGTH (m) T.WEIGHT (Kg) 17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

2R12-9(BB) 2R12-9(BB) 2R12-9(BB) R8 0.395 370.1 146.2


150 150 150
18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.
R12 0.889 381.0 338.7 19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.

R14 1.210 13.4 16.2


(D1) 1 - 1 (D1) 2 - 2 (D1) 3 - 3 20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL

R16 1.580 24.1 38.1 ENGINEER.

T.WEIGHT (Kg) 539.2 21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :

NO SIZE QUA LENGTH (mm) TOTAL FORM


MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER
28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

4570 -
1 12 2 4850 9.70
STRIP FOOTING 20 N/mm 1:3:6 0.11m3 0.21m3 0.55 27.5 LITRES
FOUNDATIONS-PAD
250 / 50 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES

25 30 N/mm 1:2:4 0.07m3 0.14m3 0.55 27.5 LITRES

2 12 2 5950 11.90 250


5660 25
25
30 N/mm 1:2:4 3
0.07m 0.14m3
40 N/mm 1:1 :3 0.053m3 0.105m3
1/2
0.55
0.5
27.5 LITRES
25 LITRES

100 100 . ABBREVIATIONS


A1 - OUTER BOTTOM REINFORCEMENT
3 8 358 950 340.10 280 280
A2 - INNER BOTTOM REINFORCEMENT
100 U1 - OUTER TOP REINFORCEMENT
U2 - INNER TOP REINFORCEMENT
R - ROUND MILD STEEL REINFORCEMENT BAR
4 12 2 2250 4.50 2230
HW - HARD WOOD
BM - BEAM
2930
5 12 8 3200 25.60 250
COL - COLUMN
G.A - GENERAL ARRANGEMENT
R.C. - REINFORCED CONCRETE
6 12 6 3750 22.50 250
3230
250

100 100

7 8 24 1250 30.00 430 430

100

2620
8 12 8 2800 22.40 180

9 12 6 10550 63.30 180


10180
180

10 12 8 1700 13.60 1700

11 12 8 2750 22.00 2730

12 12 8 2000 16.00 1990

3480
13 12 8 3700 29.60 180

14 12 2 6700 13.40 180


6480

15 12 2 4400 8.80 180


4030
180

16 12 4 1050 4.20 1010

2850
17 12 4 3150 12.60 260

18 12 4 3400 13.60 3390

19 14 2 6700 13.40 6690

20 12 2 2250 4.50 2240

21 12 4 3350 13.40 3080


250

22 12 2 9900 19.80 9640


250

Project
23 12 2 2200 4.40 2160

PROPOSED RESIDENTIAL 2-STOREY


24 12 2 1500 3.00 1470
BUILDING TO BE BUILT AT
25 12 2 1450 2.90 1430
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
26 12 2 1350 2.70 1340
ASHANTI REGION
2850
27 16 2 3100 6.20 250 Client
28 16 2 6700 13.40 6690

29 12 2 3600 7.20 3560


MR. ABDUL KADIR ISAHAK
30 16 2 2250 4.50 2240
Description

ROOF R.C BEAMS DET. 4/4


2590
31 12 2 2850 5.70 250

32 12 2 6750 13.50 250


6230
250
Scale

33 12 2 1700 3.40 1660

3150
Designed By
34 12 2 3400 6.80 250
WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446
NOTES.
1. CONTRACTOR MAY BE REQUIRED TO EXCAVATE FURTHER DEEP TO A FIRM GROUND
IF SOIL AT FOUNDATION LEVEL IS FOUND UNSUITABLE. HENCE ADDITIONAL WORK
MEASURED AND REIMBURSED ACCORDINGLY.

11H12-2-100 2. MACHINE CRUSHED GRANITE COARSE AGGREGATES OF MAXIMUM SIZE 20mm


GRADED DOWN TO 10mm SHALL BE USED, EXCEPT FOR STRIP FOUNDATIONS
WHERE MAXIMUM SIZE SHALL BE 38mm AND MUST COMPLY WITH B.S.882.

3. FINE AGGREGATES SHALL CONSIST OF SAND OR CRUSHED ROCK OF ONE OR MORE


OF TYPES GIVEN ABOVE AND MUST COMPLY WITH B.S. 882.

2H8-8-140 4. THE AGGREGATES (FINE & COARSE) SHALL NOT CONTAIN ANY HARMFUL MATERIAL
IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY THE STRENGTH,
WEAR RESISTANCE OR DURABILITY OF THE CONCRETE.

2H8-9-140 5. BLINDING SHALL BE OF GRADE C10/40 AND MASS CONCRETE OF


GRADE C20/40.

6. REINFORCED CONCRETE FOR ALL SUB-STRUCTURAL & SUPER-STRUCTURAL

11H12-4-100
11H12-1-100 16H WORKS SHALL HAVE A CHARACTERISTIC COMPRESSIVE STRENGTH fcu=30N/mm

2300 8-7
AT 28DAYS.

200 -23
0
7. MECHANICAL (POKER) VIBRATORS SHALL BE USED THROUGHOUT ALL CONCRETE
OPERATIONS.
8. THE STRUCTURAL ENGINEER RESERVE THE RIGHT TO CHANGE THE GRADING OF THE
120 400 120 400 VARIOUS AGGREGATES.

9. WATER SHALL BE CLEAN AND FREE FROM CHEMICALS AND HARMFUL MATTER.

16H 300 10. CEMENT SHALL BE ORDINARY PORTLAND (OPC) AND PORTLAND LIMESTONE (PLC)
AND MUST COMPLY WITH B.S.12.

8-7
-23 11. CEMENT OF GRADE 42.5 N EXTRA (SUPER STRENGTH) SHALL BE USED FOR ALL
560

410
0 11H12-5-100
REINFORCED CONCRETE WORKS AND GRADE 32.5R (SUPER RAPID) FOR MASONRY
WORKS.
L=2100

12. THE REINFORCEMENT SHALL UNLESS SPECIFIED OTHERWISE BE MILD STEEL

290 150 6H8-10-200


COMPLYING WITH B.S. 4449 WITH YIELD STRESS 250N/mm OR SIMILAR
11H12-16-100 L=1800

APPROVED.
560

11H12-15-100
144011H12-6-100 L=2200

560

13. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON THIS PROJECT SHALL BE


3660
1250

CERTIFIED STIPULATING THAT THE ABOVE SPECIFICATION HAS BEEN COMPLIED


11H12-5-100 L=2500

WITH.

11H12-4-100 L=950
6H8-10-200 L=2300 2260
6H8-10-200 L=2300 2260 3660 14. NOTWITHSTANDING THE PROVISION OF No. 15 ABOVE, THE CONTRACTOR SHALL AT
370 HIS OWN COST AND AS DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR THE
TENSILE AND OTHER RELEVANT TESTS.
11H
1100560

300
12-2 6H8-10-200
15. ANY CONSIGNMENT NOT MEETING THE SPECIFICATION ABOVE SHALL BE REMOVED
FROM THE SITE WITHIN 24 HOURS UPON NOTIFICATION TO DO SO BY THE
11H -10
270

STRUCTURAL ENGINEER.

12-1 0
1350

L=46
11H12-6-100
1075 150 1075 -100
L=
50 16. NO REINFORCEMENT SHALL BE WELDED WITHOUT THE WRITTEN PERMISSION
OF THE STRUCTURAL ENGINEER. BEFORE ANY WELDING IS CARRIED OUT, DETAILS
OF WELDING PROCESS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR
4500 HIS APPROVAL OR OTHERWISE.
1690

17. REINFORCEMENT WILL BE INSPECTED BY THE ENGINEER ONLY AFTER IT HAS BEEN
COMPLETELY FIXED IN POSITION WITH COVER BLOCKS IN PLACE
300

400
600

AND AFTER THE CONTRACTOR HAS INSPECTED EVERYTHING HIMSELF.

1690 11H12-5-100 L=2500 18. ALL FORMWORK MUST BE CLEAN AND SUFFICIENTLY RIGID.

19. CONCRETE SHALL BE CURED AFTER SETTING WITH MOIST SACKS FOR COLUMNS
AND MOIST SAND AND SACKS FOR BEAMS AND SLABS.
600

20. NO ADMIXTURES SHALL BE USED WITHOUT PRIOR APPROVAL OF STRUCTURAL


400

600 560 ENGINEER.

400
560 21. CONCRETE COVER TO REINFORCEMENT, MIX DESIGN AND WATER/CEMENT RATIO
AS SHOWN IN THE TABLE (1) :

120
144011H12-6-100 L=2200
50

B-B
L=47

MINIMUM VOL. OF FINE VOL. OF COARSE VOLUME OF WATER


28-DAY MIX-DESIGN WATER/CEMENT
RATIO AGGREGATES AGGREGATES PER BAG OF CEMENT (L)
COVER(mm) STRENGHT RATIO (BY WEIGHT)

STRIP FOOTING - 20 N/mm 1:3:6 0.11m3 0.21m3 27.5 LITRES


0.55
FOUNDATIONS-PAD
00

30 N/mm 1:2:4 3
0.07m 0.14m3
/ 50 0.55 27.5 LITRES

30 N/mm 1:2:4 0.55


1-1

25 0.07m3 0.14m3 27.5 LITRES


25 30 N/mm 1:2:4 3
0.07m 0.14m3 0.55 27.5 LITRES
40 N/mm 1:1 :3 0.053m3 0.105m3 0.5
00

25 25 LITRES
1/2
2700

12-1
L=44
4650

. ABBREVIATIONS
0 L=

00

A1 - OUTER BOTTOM REINFORCEMENT


11H

A2 - INNER BOTTOM REINFORCEMENT


2-1
-10

U1 - OUTER TOP REINFORCEMENT


U2 - INNER TOP REINFORCEMENT
12-1
12-2

11H12-15-100
00

R - ROUND MILD STEEL REINFORCEMENT BAR

300
0 L=45

HW - HARD WOOD
BM - BEAM
11H
11H

COL - COLUMN
6H8-10-200
-10

G.A - GENERAL ARRANGEMENT

150 R.C. - REINFORCED CONCRETE


12-1
11H

3660
400

6H8-10-200
3660
3660

50
L=12

11H12-16-100
11H12-13-100 L=1550 4-100 600

0
300

-23 R.C STAIR BENDING SCHEDULE


8-7
16H8-7-230 L=1050 1040 16H8-7-230 L=1050 1040

16H
3660

16H8-7-230 L=1050 16H8-7-230 L=1050


SIZE UNIT WEIGHT (Kg/m) Length (m) T. WEIGHT (kg)
1040 1040
12-1
11H12-3-100 L=750

H8 0.395 126.8 50.1


11H12-4-100 L=950570

11H12-12-100
11H
300

740

H12 0.889 345.4 307.0


370

200 -23
0 11H12-15-100
490

1100 L=2100
T. WEIGHT (kg) 357.1
8-7
2H8-9-140
150 L=1100 1060 2H8-9-140 L=1100 1060

16H
270

11H12-13-100 BM SIZE QTY Length (mm) TOTAL FORM


170

560
500

120 400

1 12 11 4500 49.50
3660
600 560 560
290
400

2 12 11 4650 51.15
3660
410

560
120
B

11H12-16-100 L=1800
410

2H8-17-140
1350
11H12-11-100 3 12 11 750 8.25
570
290

150

300
2H8-9-140 370

00
4 12 11 950 10.45 270 300

00
L=44
11H12-14-100
2-1 5 12 11 2500 27.50
1690

2-1
400
50

00
400
L=47

1 1H1 1 -1 6 12 11 2200 24.20 1440

12-1
600 120

11H 7 8 64 1050 67.20 1040 Project


400
8 8 2 0 0.00 PROPOSED RESIDENTIAL 2-STOREY
3660
11H12-13-100 L=1550 9 8 4 1100 4.40 1060
BUILDING TO BE BUILT AT
740
3660
10 8 24 2300 55.20 2260
PARKUSU -ASOKORE MAMPONG MUNICIPALITY
ASHANTI REGION
11 12 11 4750 52.25
3660
500
170 560

12 12 11 4400 48.40
3660
50 Client
400

00 600
500 L=12 170 560

4-1
12-1
120

MR. ABDUL KADIR ISAHAK


740

13 12 11 1550 17.05
400
490

11H
400

A-A
14 12 11 1250 13.75 120

490
600
Description

STR-01 Stairs Detail 15 12 11 2100 23.10 600


1100

400
R.C STAIRS DETAILS
Scale
16 12 11 1800 19.80 300
1350
120

Designed By
17 8 2 0 0.00 WEBUILD GH
Drawn By Drawing No.
WEBUILD GH
SEPTEMBER 2022
CONTACT 
0240020446

You might also like