BISAT PRODUCTION FACILITY (BISAT C)

SYSTEM NUMBER: XXXX


SUB-SYSTEM NUMBERS: XXXXX
SYSTEM PROCEDURE
BSTC-00-OPS-PRC-EXT- August 30,
Revision: K-00
000-00002-00 2021

5.0 CHEMICAL INJECTION SUMMARY

Chemistry Product Name Treatment Location Treat Rate Basis Frequency Monitoring Requirements Monitoring Approach

Separator Level Monitoring


Antifoam AFMR21907A u/s Inlet Separator, 02-V-1001 30 ppm Total Oil Continuous Oil Dehydration Analysis, Track & Trend
Produced Water Quality / OIW

u/s Inlet Separator, 02-V-1001 5-7 ppm Total Fluids Continuous


st
T1: u/s Desalter 1 Stage, 08-V-1005 0-10 ppm Total Fluids If required BS&W, Water Content ex. Inlet Oil
Phase Separation
Leg & Desalters
Vessel Level Stability
Demulsifier EMBR18538A T1: u/s Desalter 2nd Stage, 08-V-1008 0-10 ppm Total Fluids If required
Oil Dehydration
Analysis, Track & Trend
st
T2: u/s Desalter 1 Stage, 08-V-2005 0-10 ppm Total Fluids If required Produced Water Quality / OIW
<0.5% Water RequiredI
T2: u/s Desalter 2nd Stage, 08-V-2008 0-10 ppm Total Fluids If required

Open Drains Pump Discharge 0-50ppm Total Water Batch. If required


PW Injection Pumps 0-20ppm Total Water Continuous <10ppb Diss. O2
Oxygen Dissolved Oxygen
OSCV20002A Raw Water Transfer Pumps 0-20ppm Total Water Batch. If required Residual Bisuphite
Scavenger Residual Bisulphite
Oil Offloading Pump Discharge 0-20ppm Total Water Batch. If required Orbisphere (inline O2)
Fire Water Pumps Discharge 0-20ppm Total Water Batch. If required

Scale Inhibitor Residuals


SCAL16170A Raw Water Transfer Pumps 15 ppm Total Water Continuous Analysis, Track & Trend
Inhibitor ESEM and Ion Analysis

Corrosion Corrosion Coupons / Probes


CORR23304A Inlet Separator 15 ppm Total Fluids Continuous Analysis, Track & Trend
Inhibitor Laboratory LPR & Residuals
Produced Water Injection 500 ppm Total Water Batch – 3h Twice Serial Dilutions
Raw Water Storage Tank Total Water Weekly Serial Dilutions Analysis, Track & Trend
Biocide BIOC16039NR
No tolerance for SRB
Batch - 3h
Fire Water Storage Tank 500 ppm Total Water Serial Dilutions
Weekly
Analysis, Track & Trend
Coagulant CLAR16024A Gas Flotation Tank (GFU) 3-7ppm Total Water Continuous Produced Water Quality / OIW
OIW <50ppm