NOTES:

1. All dimensions are in millimeter unless otherwise mentioned &


levels in meter . Only written dimensions are to be followed.
2. 25 mm premoulded bituminous expansion pad shall be
WEIR AXIS provided at expansion joint.
3. Position of Returnwalls, Railings, Guard post, shall be
11200 1250 1250 1250 7750 20000 decided by Engineer in charge.
5625
4. Water spouts of 100mm dia G.I pipe are provided @ 3 m c/c.
6050 1450 9750 10250 5. Concrete shall have minimum 28 days characteristic strength
R.L +57.15 3750 on 150 mm cubes for elements of superstructure shall be
VERTICAL JOINT R.L +56.50
WITH SEAL
R.L +55.90 R.L +55.90
VERTICAL JOINT 20Mpa.
WITH SEAL
D/S WING WALL R.L +54.90
6. High strength O.P.C should be used of 43 Grade conforming
U/S WING WALL R.L +54.90
D/S DIVIDE WALL/ PIER R.L +54.50 to IS: 12269.
U/S DIVIDE WALL R.L +53.65 GATE GROOVE 7. All reinforcement bars shall be HYSD Fe-500 conforming to
D/S DIVIDE WALL/ PIER R.L +53.30
1200x1200x600 MM CC Block
U/S DIVIDE WALL R.L +53.00
IS:1786-2008.
1200 mm Thick Crated H.F.L -R.L +54.00
Boulder Pitching
with 50 mm thick joints in between POND LEVEL R.L. +53.00
UNDER SLUICE PIER
8. Cover in deck slab is 40 mm.
Pitching over 300 mm Graded Filter R.C.C M 25
CHUTE BLOCK
1200x1200x600 MM CC Block 9. Available suitable steel sheet pile conforming to I.S2314-1986.
R.L +50.00 FRICTION BLOCK
with 50 mm thick joints in between
1200 mm Thick Crated
10. R.C.C Work shall be conform to IS 456-2000.
Pitching over 300 mm Graded Filter
11. The section of various component may be adjusted as per site
1200

1200
R.C.C M 25 3:1 Boulder Pitching
1250500
1000
:1
R.L +48.50 12. Any discrepancy noticed in the drawing should be brought to

1000

1200
300

R.L +48.30 1
R.L +47.50 the notice of the chief engineer.
300 mm P.C.C M 10

300
1000

1200
13. The minimum cover in bottom raft is 75 mm and in other
1000
component 40 mm.
R.L +45.80
14. Earthen embankment of bund must be negotiated.
500 15. Angle of internal friction of back fill material of wing wall and
abutment should not be less then 30 deg.
R.L +43.00
16. Joint with water seal shall be provided at all junction of
SHEET PILE LINE
structure.
17. The actual dimension of block outs , embedded parts & gate
R.L +40.00 shall be obtained from gate design.

15000 7325 13700 1500 7500 20000 12225 25000


500 500
22825 42700 37725
HYDRAULIC PARTICULARS OF WEIR
103250

SECTION AT A - A : UNDER SLUICE PORTION

WEIR AXIS

1250 2500 7050

6050 750
R.L +57.15 3750
R.L +56.50
R.L +55.90 R.L +55.90

VERTICAL JOINT PIER


WITH SEAL
SPECIFICATION OF MATERIAL TO BE USED
200 mm Thick R.C.C M25 with
GATE GROOVE Nominal Reinforcement 1200x1200x600 MM CC Block
CHUTE BLOCK
12 mm @ 250 C/C Both ways with 50 mm thick joints in between
1200x1200x600 MM CC Block H.F.L -R.L +54.00 Pitching over 300 mm Graded Filter 1200 mm Thick Crated
1200 mm Thick Crated with 50 mm thick joints in between POND LEVEL R.L. +53.00 FRICTION BLOCK Boulder Pitching
Boulder Pitching R.L +52.00
Pitching over 300 mm Graded Filter 1250
3 : 1R.C.C M 25 500
2:1 1000 R.L +50.80
:1
1000

1200
1
R.L +50.00 R.L +49.80
1000
1200

300
1200

P.C.C M 15
1800
2400

R.L +48.50
1000
300

R.L +47.30
1000

R.L +46.00
3700 13200 300 mm P.C.C M 10 GOVT. OF BIHAR
SHEET PILE LINE WATER RESOURCES DEPARTMENT
R.L +44.00 CHIEF ENGINEER , IRRIGATION CREATION W.R.D DARBHANGA
CONSTRUCTION OF GATED WEIR & ALLIED STRUCTURES IN THE RIVER
8000 3650 6000 4000 2000 6600 12000 7325 15000 SUGERWAY AT MADANPATTI , PHULPARAS BLOCK MADHUBANI
500 500
12150 30600 22825
65575

Western Kosi Canal division Design and Mont. Division Western Kosi Canal Circle
Jhanjharpur Darbhanga Jhanjharpur

Approved by
SECTION AT B - B : WEIR PORTION

Design and Mont. Circle IRRIGATION CREATION W.R.D DARBHANGA


Darbhanga