INDUSTRIAL (A NABL Accredited Laboratory Certificate No.: CC-2986)


SOLUTION
CALIBRATION CERTIFICATE

User's Name & Address: Certificate No. 2S[S/W%/0081/2


I\,I/s SARENS HEAVY LIFT INDIA PVT. LTD. Date Of Receipt: 0544-2023
2nd & 3rd Floor, Plot No. - 19 & 2O Sector -L25, Noida, G. B. Nagar. Date of Calibraton: 0544-208
Date of Issue: 0@-nB
Next Due Date Requested by Customer : M-04-2024
InstrumentDetail(s)
Equip. For Calibration Crane Safe Load Indicator Identificafion No. SU-01
Make Grove Serial No.. 51302004
Model No. GMK5130-l Were Rope Dia 19mm
Range/Size 40.1 Ton Location Crane
Least Count 0.1 Ton Visual Inspection OK
Environmental Condition Maintained During Calibration

Temperature : 26.8'C Relative Humidity : 56%


Reference Standard ( s ) / Master Equipment Used For Calibration

s.N. Nomenclafure Make Id./Sr. No. Certificate No. Due Date of Calibration Calibrated By
1. 6.5 Digit Precision Multimeter Fluke 2s.ls/Er/02 cc202022000000837F 04-11.-2023 AIPLNoida
2. Multifunction Calibrator ( 5% Digit ) Megatronics 2S1S/ET /01. PPL/07-23/0076/4 75-07-2024 PPL-Noida
3. S.S. Weights Weightronics 2SI$SW-02 T\E/W / 07 /2022/ 568 22-06-2023 Tycon Engg.
Traceability : Master equipment used are traceable to S.l. units through unbroken chain calibration from NABL accredited lab. / competent
competent lab. / NPL, New Deihi.

Calibration Method Used: WI-065M (Comparison Method ) &


at:
Calibration performed On Site II Reference Standard : lS : 14473
CalibrationResult(s)
Nominal Value ( UUC ) Observed Value (Master )
Sr. No.
(Ton) (Ton)
1. 5 5.04
) 10 10.08

3. 15 15.11

4. 20 20.18

5. 30 30.20

6. 35 35.%

Uncertainty Of Measurement : I 1.0 % ( The reported uncertainty is at coverage factor k = 2,


tr\lhich correspond to coverage probability of approximately 95 % ol anormal distribution. )

NOTE: -
1. The calibration results reported in this certificate are valid at the time and the stated condition of measurement.
2. This report should not be reproduced except in full without our prior permission in writing.
3. UUC : - Unit Under Calibration / GUT : - Gauge Under Testing.
4. Calibration certificate without signature are not valid.
5. The results stated in the certificate reiates to the referred calibrated item only.
6. The details of calibrated item, referred in the certificate are mentioned as per the informantion provided by customer ordy.
, 7. CAB establishes haceability of its measurement standards to the Si by means of an unbroken chain of calibrations or comparisions

302, BasundharaApartment, NearCentral Bank, Rasulgarh,.Bhubaneswar-751010


Ph.: (+91674) 2581037, Cell : +91-7609057106, +91-6370190415, +91-9717733244, E-mail : 2sis.bbsr@grpail.com / s2sindustrial@yahoo.com, Web : www.2sis.co.in
2S
INDUSTRIITL (A NABL Accredited Laboratory Certificate No.: CC-2986)
SOLUl]ION
CALIBRATION CERTIFICATE
2SlSIFl7.8l07 I Paee 1 of 1

User's Name & Address : Certificate No. 2515/0+23/0081./3


N,f/s SARENS TIEAVY LIFT INDIA PVT. LTD. Date Of Receipt: 054+20?3
2"a & 3'u Floor, Plot No. - 19 & 2O Sector -125, Noida G. B. Nagar. Date of Calibration: 05-0+2023
Date of Issue : 064+2023
Next Due Date Requested by Customer : M-M-2024
InstrumentDetail(s)
Equip. For Calibration Digital Anemometer Identification No. Amm-01
Make Serial Nol
ModelNo. Location Lfane
Range/Size (0to40)m/s Visual InspecHon OK
Least Count 0.1 m/s
Environmental Condition Maintained During Calibration

Temperafure t 26,8"C Relative Humidity : 56o/o

Reference Standard ( s ) / Master Equipmenf Used For Calibration

s.N. Nomenclature Make Id./Sr. No. Certificate No. Due Date of Calibration Calibrated By

1 Hot Wire Anemometer Lutron Q868s88 cc2864230000000192F 21-03-2025 EI-G.Noida

Traceability @S.I.unitsthroughunbrokenchainofcalibrationfromNABLaccreditedlab,/competentlab./NPL,Nex,
equipment through

at:
Calibration Performed On Site I Calibration Method Used: WI-034M ( Comparison Method )

ealbretles ncqgltl-El
Standard Reading (Master ) Measured Reading (UUC )
Sr. No. (ry's)
( rry's )

1,. L.6 1.8

2. L) 4.5

3. 1,0.4 1.4.2

4. 1,6.9 16.4

5. 19.6 1,9.3

Uncertainty Of Measurement : + 3.5 o/r,


rdg ( The reported uncertainty is at coverage tactor k = 2,
l\rhich correspond to coverage probability of approximately 95'ft of a normal distribution. )

NOTE : -
1. The calibration results reported in this certificate are valid at the time and the stated condition of measurement'
2. This report should not be reproduced except in ful1 without our prior permission in writing.
3. UUC : - Unit Under Calibration / GUT : - Gauge Under Testing.
4. Calibration certificate without signature are not valid.
5. The results stated in the certificate relates to the referred calibrated item only.
6. The details of calibrated item, referred in the certificate are mentioned as per the informantion provided by customer only.
, 7. CAB establishes kaceability of its meajurement standards to the SI by means of an unbroken chain of calibrations or comparisions
Linking them to relevant primary standards of the SI units of measurement, The link to SI units may be achieved by reference to

,#.ru\
ional/lntemational measurement standards. n
\r,-{
.^WKuy ftf*=ffi tssu"a)'appioved Bv

C. R. JENA VffiFl . , sANTosH KUnilAR s1ffAtN


Callbration Engineer \-S,\_/*Y , (oM/rM)