Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Scala 1-2 DataBooklet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 35

GRUNDFOS DATA BOOKLET

SCALA
Multistage centrifugal boosters, 50/60 Hz
SCALA

1. Product introduction . . . . . . . . . . . . . . . . . . . 3
Table of contents

Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Features and benefits . . . . . . . . . . . . . . . . . . . . .3
Pumped liquids. . . . . . . . . . . . . . . . . . . . . . . . . .3
Product range. . . . . . . . . . . . . . . . . . . . . . . . . . .4
Performance range . . . . . . . . . . . . . . . . . . . . . . .5

2. Selection guide . . . . . . . . . . . . . . . . . . . . . . . 6

3. Installation and operation . . . . . . . . . . . . . . . 7


Mechanical installation. . . . . . . . . . . . . . . . . . . . .7
Installation examples . . . . . . . . . . . . . . . . . . . . . .9
Electrical connection . . . . . . . . . . . . . . . . . . . . . 11
Motor protection . . . . . . . . . . . . . . . . . . . . . . . . 11

4. SCALA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Product range. . . . . . . . . . . . . . . . . . . . . . . . . . 12
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Features and benefits of SCALA1 . . . . . . . . . . . . 12
Protection features . . . . . . . . . . . . . . . . . . . . . . 12
Performance curves . . . . . . . . . . . . . . . . . . . . . 13
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 15
Approvals and markings . . . . . . . . . . . . . . . . . . 18
Suction performance . . . . . . . . . . . . . . . . . . . . . 19

5. SCALA1 twin booster system . . . . . . . . . . . 20


Features and benefits . . . . . . . . . . . . . . . . . . . . 20
Protection features . . . . . . . . . . . . . . . . . . . . . . 20
Operating modes . . . . . . . . . . . . . . . . . . . . . . . 20
Performance curves . . . . . . . . . . . . . . . . . . . . . 21
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 22

6. SCALA2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Features and benefits of SCALA2 . . . . . . . . . . . . 23
Protection features . . . . . . . . . . . . . . . . . . . . . . 23
Performance curves . . . . . . . . . . . . . . . . . . . . . 24
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 25
Approvals and markings . . . . . . . . . . . . . . . . . . 27
Suction performance . . . . . . . . . . . . . . . . . . . . . 27

7. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 28
SCALA twin accessory set . . . . . . . . . . . . . . . . . 28
SCALA2 accessories. . . . . . . . . . . . . . . . . . . . . 29

8. Product numbers . . . . . . . . . . . . . . . . . . . . . 31
SCALA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SCALA2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

9. Grundfos Product Center . . . . . . . . . . . . . . 34

2
SCALA
1

Product introduction
1. Product introduction
Features and benefits
General benefits of SCALA pumps:
• Easy installation.
• Easy commission.
• Easy operation.

Features SCALA1 SCALA2


Auto start-stop √ √

TM075413
Self-priming √ √
Alarm indication √ √
Dry-running protection √ √
Left to right: SCALA1, SCALA2 Anti-cycling protection √ √
Maximum runtime
√ √
protection
Grundfos SCALA pumps are all-in-one integrated
pressure boosters designed for domestic use and ensure Bluetooth
√ -
communication
a constant supply of clean water to households, gardens
and light commercial applications. Twin enabled √ -
External input √ -
Adjustable constant
SCALA1 pressure
- √
Grundfos SCALA1 is a self-priming, multistage pump, Integrated frequency
which combines all the components of a pressure booster - √
converter
into a compact composite enclosure. Low noise 55 dB(A) 47 dB(A)
SCALA1 can communicate with Grundfos GO Remote
app through a built-in Bluetooth technology, which Pumped liquids
enables high customization options, making this pump a
good fit for every application. The product is suitable for pumping clean, thin, non-
aggressive and non-explosive liquids without solid
particles or fibres.
SCALA2 The product is designed for fresh water with a maximum
Grundfos SCALA2 is a fully integrated, self-priming, chloride content of 300 ppm and a free chlorine content
compact waterworks for pressure boosting in domestic below 1 ppm.
applications. Examples of liquids:
SCALA2 incorporates integrated speed control which
allows maintaining a perfect pressure in the taps. This • drinking water
means that the pump performance will adjust to the the • rainwater.
increasing demand.

Applications
The SCALA boosters are suitable for domestic and light
commercial water supply, where pressure boosting is
required.
We recommend SCALA pumps for the following
applications:
• pressure boosting of city mains water
• pressure boosting of water from roof tank
• pressure boosting of water from break tank
• pressure boosting of water from ground tank
• water supply from shallow wells [8 m (26.2 ft)]
• garden irrigation
• water transfer.

Depending on the application needs and required comfort,


one pump can be a better fit than the other.

3
1 SCALA

Product range
Product introduction

Nominal flow rate Max. head


Pump type
[m3/h (gpm)] [m (ft)]
SCALA1 3-25 3 (13) 25 (82)
SCALA1 3-35 3 (13) 35 (114)
SCALA1 3-45 3 (13) 45 (147)
SCALA1 5-25 5 (22) 25 (82)
SCALA1 5-35 5 (22) 40 (131)
SCALA1 5-55 5 (22) 55 (180)
SCALA2 3-45 3 (13) 45 (147)

4
SCALA
1

Performance range

Product introduction
The performance curves show the range of the SCALA
pumps.

H H
[ft] [m]
SCALA1
180 55 60 Hz

50
160
5-55

45
140
40
3-45
120
35

100 30
3-35

80 25

20
60
3-25
15

40
10

20
5
5-25
TM075223

TM075369
0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 Q [m³/h]

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [US GPM]

Performance range, SCALA1 50 Hz


Performance range, SCALA1 60 Hz

TM1040464

Performance range, SCALA2 50/60 Hz

5
2 SCALA
Selection guide

2. Selection guide

This guide helps you to size and select the most suitable SCALA product.
Follow the instructions below to determine which product variant is best suited to your needs.

1. Choose the right pump for your application.

Application Pump Suitability rating Recommendation


SCALA1 ● ●

City water mains Due to integrated frequency converter, SCALA2 can adapt the speed to varying
SCALA2 ● ● ● water pressure in the city mains, delivering constant pressure in all taps any time.
PN10 rating ensures robustness towards maximum system pressure.
SCALA1 construction offers better suction capabilities with different modes to handle
SCALA1 ● ● ●
Shallow well air.
SCALA2 ● ●
SCALA1 ● ●
Water storage tank (above
ground level) Adjustable constant pressure for SCALA2 enables user to select the desired
SCALA2 ● ● ●
pressure for the entire home, and thus avoids overpressure.
SCALA1 construction offers better suction capabilities with different modes to handle
Water storage tank (below SCALA1 ● ● ●
air.
ground level)
SCALA2 ● ●
SCALA1 ● ●
Roof tank Adjustable constant pressure for SCALA2 enables user to select the desired
SCALA2 ● ● ●
pressure for the entire home, and thus avoids overpressure.
External input and fixed speed in SCALA1 will make sure water is transferred as
SCALA1 ● ● ●
Water transfer quickly as possible from point A to B, when needed.
SCALA2 ●

External input and calendar function are a perfect combination for irrigation
SCALA1 ● ● ●
Garden irrigation purposes.
SCALA2 ●
SCALA1 ● ●
Kitchen
SCALA2 ● ● ● SCALA2 delivers constant pressure to all taps regardless of the inlet pressure.
SCALA1 ● ●
Bathroom
SCALA2 ● ● ● SCALA2 delivers constant pressure to all taps regardless of the inlet pressure.

2. Size your pump.

Number of floors 1-5 taps 6-10 taps 11-20 taps 21-50 taps
SCALA1 3-45 or
4 SCALA1 5-55 SCALA1 Twin 5-55 SCALA1 Twin 5-55
SCALA2 3-45
SCALA1 3-45 or SCALA1 3-45 or
3 SCALA1 5-55 SCALA1 Twin 5-55
SCALA2 3-45 SCALA2 3-45
SCALA1 3-35 or SCALA1 3-45 or SCALA1 5-55 or SCALA1 Twin 5-55 or
2
SCALA2 3-45 SCALA2 3-45 SCALA1 5-35 SCALA1 5-35
SCALA1 3-25 or SCALA1 3-35 or SCALA1 3-45 or SCALA1 Twin 5-55 or
1
SCALA2 3-45 SCALA2 3-45 SCALA2 3-45 SCALA1 5-35

Preconditions:
• A tap pressure of 3 bar (43.5 psi) is considered. To achieve pressure of 4 bar (58 psi), remove two floors.
• The inlet is flooded. For suction operation, remove a floor for every 3 metres (9.84 ft) of suction depth.
• A tap flow between 9 (2.4 gpm) and 12 l/min (3.2 gpm) average usage and half of the taps opened at the same time
will be considered.

6
SCALA
3

Installation and operation


3. Installation and operation
Mechanical installation Inlet and outlet pipes
Placing the pump above ground is generally a convenient Follow these general precautions when connecting the
way to establish water or rainwater supply. The pump can inlet and outlet pipes.
be installed both indoors and outdoors. • Install the pipes so that air pockets are avoided,
The product should be placed as close as possible to the especially on the inlet side of the pump.
liquid to be pumped to minimize the length of the inlet • Use eccentric reducers with the tapered side down.
pipe. The motor is water-cooled, but we still recommend a
clearance of 0.5 m (1.64 ft) on three sides of the product. • Make sure the pipes are as straight as possible to
The product should be fastened to a solid horizontal avoid unnecessary bends and fittings. We recommend
foundation with a maximum inclination angle of ± 5 °. The long-radius 90 ° pipe bends to decrease friction loss.
base plate must be facing downwards. • If possible, run a horizontal inlet line. We recommend
If the pump is used for pumping rainwater or well water, a gradual upward slope for pumps operating in
we recommend installing a filter on the inlet side to protect suction-lift conditions.
the pump from sand, gravel or other debris. If the pump is • A short pipe must be of the same diameter as the inlet
installed above the liquid level, we recommend fitting a port or larger.
foot valve with a strainer to the inlet pipe.
• A long pipe must be one or two sizes larger than the
Pipe system inlet port, depending on the length.
To obtain the optimum suction capacity which the dry-
installed pump is designed for, the correct dimension of
the pipe system is important. If a hose is used as inlet
pipe, it must be non-collapsible.
The diameter of the inlet pipe must be larger than 1", if the
inlet pipe is longer than 10 m (32.8 ft), or if the suction lift
exceeds 4 m (13.1 ft).

Inlet pipe length and suction lift


The length of the inlet pipe of self-priming pumps depends

TM040338
on the geodetic suction lift. The recommended maximum
length of the inlet pipe according to the suction lift is
shown in the figure below. The example shows that if the
suction lift is 2.5 m (8.2 ft), the length of the inlet pipe Recommended pipe installation to avoid friction and air
must not exceed 25 m (82 ft). pockets

[ft] [m]
9
8
25
7
20 6
5
15
4
10 3
2
TM075387

5
1
0
4 8 12 16 20 24 28 32 36 40 [m]
[ft] Correct pipe sizing for connection to the pump inlet or
15 45 75 105 120 outlet
TM075339

Maximum inlet pipe length (horizontal axis) according to


the suction lift (vertical axis)

7
3 SCALA

Maximum system pressure


Installation and operation

Make sure that the system in which the pump is


installed is designed for the maximum pump pressure.

When installing a non-return valve in the plumbing


system, make sure that the system has an expansion
tank at the water heater and that the pressure-relief
valve in the water heater is plumbed to a drain. Carry
out the installation in accordance with local regulations.

The maximum inlet pressure depends on the head at the


actual duty point. The sum of the inlet pressure and the
head must not exceed the maximum system pressure.
We recommend installing a pressure-relief valve to protect
the pump so that the outlet pressure does not exceed the
maximum system pressure.

8
SCALA
3

Installation examples Suction from a tank

Installation and operation


We recommend that you follow the installation examples.
Valves are not supplied with the pump.

Suction from a well 1

2
3 3 4
1

5
A

6
7

TM075007
H1

5 4
8

Pos. Description
1 Highest tapping point
H2

6
TM075006

2 Pipe hangers
3 Isolating valve
4 Flexible hoses
5 Drain to sewer
Pos. Description
6 Inlet filter
1 Highest tapping point
7 Freshwater tank
2 Isolating valve
8 Foot valve with strainer
3 Flexible hoses
9 Minimum 1-degree inclination
4 Pipe support
5 Inlet filter
6 Foot valve with strainer
H1 Maximum suction lift: 8 m (26.2 ft)
H2 Inlet pipe must be submerged at least 0.5 m (1.64 ft)

9
3 SCALA

Mains water pressure boosting, SCALA1 Mains water pressure boosting, SCALA2
Installation and operation

1 1

2 2

7 3 9 4
7 3 9 4

10
10
5 6
2 5 6 2

8
8

TM075262

TM064347
3
3

Mains water pressure boosting, SCALA1 Mains water pressure boosting, SCALA2

Pos. Description Pos. Description


1 Highest tapping point 1 Highest tapping point
2 Pipe hangers and supports 2 Pipe hangers and supports
3 Isolating valves 3 Isolating valves
4 Flexible hoses 4 Flexible hoses
5 Bypass valve 5 Bypass valve
Optional pressure-reducing valve on the inlet side if Optional pressure-reducing valve on the inlet side if the pressure
6 6
the system pressure can exceed 8 bar (115 psi). can exceed 10 bar (145 psi).
Optional pressure relief valve on the outlet side if the Optional pressure-relief valve on the outlet side if the installation
7 7
installation cannot withstand the outlet pressure. cannot withstand a pressure of 6 bar (87 psi).
Drip tray. Install the pump on a small stand to prevent Drip tray. Install the pump on a small stand to prevent the
8 8
the ventilation holes from being flooded. ventilation holes from being flooded.
9 Pressure gauge 9 Pressure gauge
10 Mains water pipe 10 Mains water pipe

10
SCALA
3
Roof tank filling Electrical connection

Installation and operation


The electrical connection and protection must be carried
out in accordance with local regulations. Please also
observe the following requirements:
1
• Make sure that the pump is suitable for the power
5 supply to which they are to be connected.
• The pump must always be correctly earthed.
• The plug on the pump must have the same protective
earth (PE) connection system as the power outlet. If
not, use a suitable adapter if allowed by local
regulations.
• A pump without plug must be connected to an external
main switch or wired with a plug.
2
Motor protection
The pump incorporates current- and temperature-
dependent motor protection. If the pump is blocked or
3 otherwise overloaded, the built-in thermal switch will cut
out. When the motor has cooled sufficiently, it will restart
automatically.
No external motor protection is required.

4
TM075330

Pos. Description
1 Float switch
2 External input (switch) cable
3 Pump
4 Water source (tank)
5 Roof tank

11
4 SCALA
SCALA1

4. SCALA1
Self-priming
A self-priming pump ensures a stable operation, even if
the pump is not fully filled with liquid. The self-priming
pump is able to lift liquid from below the inlet level and
handle a mix of air and liquid until the pump reaches a
fully-primed pumping condition.

Robust design
The pump is designed for long and trouble-free
operation.Composite construction combined with excellent
corrosion-resistant internal components ensure high
robustness in operation.

Easy installation

TM075390
All-in-one fully integrated plug-and-pump solution
eliminating any uncertainties found in traditional
SCALA1 pump installations.

Protection features
Grundfos SCALA1 is a self-priming, multistage pump,
which combines all of the components of a pressure Dry-running protection
booster into a compact composite enclosure. The product incorporates dry-running protection that
SCALA1 can communicate with the Grundfos GO Remote automatically stops the pump from running without
app through a built-in Bluetooth technology, which liquid. Dry-running protection means less risk of pump
enables high customization options, making this pump a damage and lower maintenance costs.
good fit for every application.
Anti-cycling function
Product range The anti-cycling function prevents the product from
starting and stopping too often in case of a minor leakage
Nominal flow rate Max. head in the system or if a tap has not been closed completely.
Pump type
[m3/h (gpm)] [m (ft)] The anti-cycling function will stop the pump, and an alarm
SCALA1 3-25 3 (13) 25 (82)
will be indicated.
SCALA1 3-35 3 (13) 35 (114) Maximum runtime
SCALA1 3-45 3 (13) 45 (147) The maximum runtime function is a timer that can turn the
SCALA1 5-25 5 (22) 25 (82) pump off if it runs continuously for a certain amount of
SCALA1 5-35 5 (22) 55 (180) time. This time period is adjustable via Grundfos GO
SCALA1 5-55 5 (22) 55 (180) Remote app.

Motor
The motor is water-cooled and equipped with sealed,
greased-for-life ball bearings to ensure silent operation
and minimum service. The motor has a built-in thermal
switch and requires no additional motor protection.

Features and benefits of SCALA1


• Water on demand.
• All-in-one integrated booster.
• Bluetooth communication.
• External input.
• Twin booster enabled.
• Low noise level < 55 dB(A).

12
SCALA
4

Performance curves

SCALA1
50 Hz 60 Hz
H H H H
[ft] [m] [ft] [m]
SCALA1 3-25 SCALA1 3-25
28 28
90 50 Hz 90 60 Hz
80 24 80 24
70 70
20 20
60 60
16 16
50 50

40 12 40 12

30 30
8 8
20 20
4 4
10 10

0 0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 Q [m³/h]

0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM] 0 2 4 6 8 10 12 14 16 18 20 Q [US GPM]


P1 P1 P1 P1
[hp] [W] [hp] [W]
0.8 600 0.8 600
500 500
0.6 0.6
400 400
0.4 300 0.4 300
200 TM075218

TM075364
200
0.2 0.2
100 100
0.0 0 0.0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 Q [m³/h]

H H H H
[ft] [m] [ft] [m]
40
SCALA1 3-35 120 SCALA1 3-35
50 Hz 35
60 Hz
120
35
100 30
100 30
80 25
80 25
20
20 60
60
15
15
40
40
10 10

20 20
5 5

0 0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Q [m³/h]

0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM] 0 2 4 6 8 10 12 14 16 Q [US GPM]


P1 P1 P1 P1
[hp] [W] [hp] [W]
800 800
1.0 1.0
0.8 600 600
0.8
0.6 0.6
400 400
0.4

TM075365
TM075219

0.4
200 200
0.2 0.2
0.0 0 0.0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Q [m³/h]

H H H H
[ft] [m] [ft] [m]
45 SCALA1 3-45 45 SCALA1 3-45
140 50 Hz 140 60 Hz
40 40
120 120
35 35

100 30 100 30

80 25 25
80

20 20
60 60
15 15
40 40
10 10
20 20
5 5

0 0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 Q [m³/h]

0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM] 0 2 4 6 8 10 12 14 16 18 20 Q [US GPM]


P1 P1 P1 P1
[hp] [W] [hp] [W]
1.4 1000 1.4 1000
1.2 1.2
800 800
1.0 1.0
0.8 600 0.8 600
0.6 400 0.6 400
TM075366
TM075220

0.4 0.4
200 200
0.2 0.2
0.0 0 0.0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 Q [m³/h]

13
4 SCALA

50 Hz 60 Hz
SCALA1

H H H H
[ft] [m] [ft] [m]
SCALA1 5-25 SCALA1 5-25
100 100
30 60 Hz 30 60 Hz

80 25 80 25

20 20
60 60

15 15

40 40
10 10

20 20
5 5

0 0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Q [m³/h] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Q [m³/h]

0 2 4 6 8 10 12 14 16 18 20 22 24 Q [US GPM] 0 2 4 6 8 10 12 14 16 18 20 22 24 Q [US GPM]


P1 P1 P1 P1
[hp] [W] [hp] [W]
800 800
1.0 1.0

0.8 600 0.8 600

0.6 0.6
400 400

TM075367

TM075367
0.4 0.4
200 200
0.2 0.2

0.0 0 0.0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Q [m³/h] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Q [m³/h]

Not available
TM084369

H H H H
[ft] [m] [ft] [m]
180 55 SCALA1 5-55 180 55 SCALA1 5-55
50 50 Hz 50 60 Hz
160 160
45 45
140 140
40 40
120 120
35 35
100 30 100 30

80 25 80 25

20 20
60 60
15 15
40 40
10 10
20 5 20 5

0 0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 Q [m³/h] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 Q [m³/h]

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [US GPM] 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28Q [US GPM]


P1 P1 P1 P1
[hp] [W] [hp] [W]
1400 1400
1.8 1.8
1.6 1200 1.6 1200
1.4 1000 1.4 1000
1.2 1.2
800 800
1.0 1.0
TM075368

0.8 600 0.8 600


TM075222

0.6 400 0.6 400


0.4 0.4
200 200
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 Q [m³/h] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 Q [m³/h]

14
SCALA
4

Technical data

SCALA1
Dimensions and weights

DN2
DN1

H1

H2
H3

TM075267
W1 L1

H1 H2 H3 L1 W1
Pos. [mm] [mm] [mm] [mm] [mm]
[inch] [inch] [inch] [inch] [inch]
316 263 171 466 202
SCALA1 (all variants)
12.4 10.4 6.7 18.4 8.0

Weight
SCALA1 3-25 SCALA1 3-35 SCALA1 3-45 SCALA1 5-25 SCALA1 5-35 SCALA1 5-55
[kg] [kg] [kg] [kg] [kg] [kg]
[lb] [lb] [lb] [lb] [lb] [lb]
11 12 12 12 12 14
24.2 26.4 26.4 26.4 26.4 30.8

Operating conditions

SCALA1
3-25 3-35 3-45 5-25 5-35 5-55
55 °C 55 °C 55 °C 55 °C 55 °C 55 °C
Max. ambient temperature
(131 °F) (131 °F) (131 °F) (131 °F) (131 °F) (131 °F)
45 °C 45 °C 45 °C 45 °C 45 °C 45 °C
Max. liquid temperature
(113 °F) (113 °F) (113 °F) (113 °F) (113 °F) (113 °F)
Maximum system pressure [bar
8 (116) 8 (116) 8 (116) 8 (116) 8 (116) 8 (116)
(psi)]
Maximum inlet pressure [bar
5 (72.5) 4 (58) 3 (43.5) 5 (72.5) 4 (58) 2 (29)
(psi)]
Max. head [m (ft)] 50 Hz 25 (82) 36 (118.1) 44 (144.3) 26 (85.3) 40 (131.2) 52 (170.6)
Max. head [m (ft)] 60 Hz 25 (82) 35 (114.8) 46 (150) 27 (85.3) - 55 (180)
Nominal head [m (ft)] 15 (49.2) 20 (65.6) 25 (82) 15 (49.2) 20 (65.6) 25 (82)
Nominal flow [m3/h (gpm)] 3.00 (12.19) 3.72 (16.38) 3.59 (15.80) 4.80 (21.12) 4.92 (21.66) 5.33 (23.48)
IP Rating X4D X4D X4D X4D X4D X4D
Pumped liquids Clean water Clean water Clean water Clean water Clean water Clean water
Noise level [db(A)] < 55 < 55 < 55 < 55 < 55 < 55
Frequency of starts and stops 25 per hour 25 per hour 25 per hour 25 per hour 25 per hour 25 per hour
Start pressure (pstart) [bar (psi)] 1.2 (17.4) 1.5 (21.8) 2.2 (31.9) 1.2 (17.4) 1.5 (21.7) 2.8 (40.6)

15
4 SCALA

Electrical data
SCALA1

All variants have insulation class F.

50 Hz
Voltage P1 P2 n In Istart Standby power
Pump type
[V] [W (hp)] [W (hp)] [rpm] [A] [A] [W]
SCALA1 3-25 1 x 230 550 (0.74) 360 (0.50) 2850 2.58 13.0 1.5
SCALA1 3-35 1 x 230 720 (0.97) 450 (0.60) 2800 3.27 13.0 1.5
SCALA1 3-45 1 x 230 910 (1.23) 580 (0.80) 2800 4.10 17.0 1.5
SCALA1 5-25 1 x 230 650 (0.88) 425 (0.60) 2850 3.00 13.0 1.5
SCALA1 5-35 1 x 230 890 (1.19) 450 (0.60) 2800 3.60 20.0 1.5
SCALA1 5-55 1 x 230 1200 (1.62) 780 (1.00) 2850 5.38 26.0 1.5

60 Hz
Voltage P1 P2 n In Istart Standby power
Pump type
[V] [W (hp)] [W (hp)] [rpm] [A] [A] [W]
1 x 230 540 (0.72) 350 (0.50) 3450 2.37 13.0 1.5
SCALA1 3-25
1 x 115 560 (0.75) 350 (0.50) 3450 5.10 29.5 1.5
1 x 230 650 (0.88) 470 (0.60) 3400 2.76 13.0 1.5
SCALA1 3-35
1 x 115 650 (0.88) 470 (0.60) 3400 5.71 29.5 1.5
1 x 230 870 (1.17) 570 (0.80) 3350 3.72 15.5 1.5
SCALA1 3-45
1 x 115 950 (1.28) 590 (0.80) 3400 8.62 40.0 1.5
1 x 230 600 (0.80) 420 (0.60) 3450 2.60 13.0 1.5
SCALA1 5-25
1 x 115 610 (0.82) 450 (0.60) 3450 5.70 29.5 1.5
1 x 230 1250 (1.68) 810 (1.10) 3450 5.25 22.5 1.5
SCALA1 5-55
1 x 115 1250 (1.68) 860 (1.10) 3450 11.57 64.0 1.5

16
SCALA
4
Construction of SCALA1

SCALA1
5

15
10
11 6

8
9
18

14 13
12

16

TM075375
17

Exploded view of SCALA1

Material specification
Pos. Component Material
1 Combined pump and stator housing Composite
4 PCB cover Composite
5 Cover for control box Composite
7 Motor flange Composite
8 Shaft seal, complete Carbon/Ceramic
9 Chamber stack Composite
11 Air handling unit Composite
14 Connection part for hydraulic Composite
15 Non-return valve discharge Composite
16 Cover for hydraulic Composite
17 Drain plug Composite
18 Fittings, thread R 1" / NPT 1" Composite

17
4 SCALA

Approvals and markings


SCALA1

Safety approvals

TM074611

TM074115
TM075405

Drinking water approvals

ACS TM074613

TM074116

18
SCALA
4

Suction performance

SCALA1
H H H H
[ft] [m] [ft] [m]
26 SCALA1 SCALA1
80 3-25 40 3-35
24
120
22 35
70
20
100 30
60 18
16 25
50 80
14
40 12 20
60
10
30 15
8 40
0m
20 6 10
7m 6m 1m
4 8m 5m 20
10 2m 5
2
4m 8m 7m 6m 5m 4m 0m
3m
3m 2m 1m
0 0 0 0

TM075531

TM075532
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
Q [m³/h] Q [m³/h]

0 2 4 6 8 10 12 14 16 18 Q [US GPM] 0 2 4 6 8 10 12 14 16 18 Q [US GPM]

H H H H
[ft] [m] [ft] [m]
45
SCALA1 26 SCALA1
140 3-45 80 24 5-25
40 22
70
120 20
35
60 18
100 30
16
50
80 25 14
40 12
20
60 10
30
15 8
40
10 20 6
6m 5m 4m 1m
8m 7m 2m 0m
7m 4
20 6m 0m 10 3m
5 5m
8m 4m 1m 2
3m 2m
0 0 0 0
TM075533

TM075534
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
Q [m³/h] Q [m³/h]

0 2 4 6 8 10 12 14 16 18 20 Q [US GPM] 0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]

H H
[ft] [m]
180 55 SCALA1
5-55
50
160
45
140
40
120
35
100 30

80 25

20
60
15
40
10
20 5 1m
8m 7m 6m 5m 4m 2m 0m
3m
0 0
0 1 2 3 4 5 6 7 8
TM075535

Q [m³/h]
TM084481

0 5 10 15 20 25 Q [US GPM]

19
5 SCALA
SCALA1 twin booster system

5. SCALA1 twin booster system


Alternate on runtime
Pump 1 will be the first to start until it accumulates the
defined number of running hours. After that, Pump 2 will
start first.
Alternate on number of starts
Pump 1 will be the first to start until it accumulates the
defined number of starts. After that, Pump 2 will start first.

Grundfos GO Remote enabled


SCALA1 twin booster system can be connected to
Grundfos GO Remote via Bluetooth communication to be
able to adjust the system parameters to specific user
needs.

Protection features
TM075391 SCALA1 twin booster has all the protective functions of
the SCALA1 pump.
Dry-running protection will stop each pump separately,
SCALA1 twin booster system
while the anti-cycling protection and maximum runtime
protection will stop the system.
SCALA1 can be easily setup as a twin booster, in case
there is a need for a stand-by pump or higher flow Operating modes
demand.
Duty/Assist
For this purpose, there is a dedicated accessory set that
includes: In Duty/Assist, both pumps can run at the same time,
delivering more flow on the outlet side.
• base plate
If one pump is unable to meet the demand, the second
• inlet and outlet manifolds with valves pump will start up.
• communication cable Duty/Standby
• fixing screws. In this mode, only one pump will run at a time, while the
In the twin setup, the two SCALA1 pumps communicate other pump will remain as a standby pump.
together via a cable included in the accessory kit, Based on alternation settings, the pumps will switch
enabling optimum double-pump operation. priority in starting.

Features and benefits


The twin system has all the features and benefits of the
SCALA1 pump, along with the ability to handle increased
flow demand.

Easy installation
SCALA1 twin booster can be quickly installed. After the
pumps are mounted on the base plate and connected with
a cable and manifolds, it is only a matter of connecting to
the pipe system.
Once the system is primed, it is ready to deliver water.

Alternation
Once the communication cable is connected and the
system powered on, the pumps are automatically
assigned a priority at the start.
Alternation determines when the pumps will switch priority
in starting, enabling equal use during operation lifetime.
Grundfos GO Remote allows selecting the following
options:
• alternate on runtime
• alternate on the number of starts.

20
SCALA
5

Performance curves

SCALA1 twin booster system


H H
[ft] [m] H H
SCALA1 3-25 [ft] [m]
28
120 36 SCALA1 3-35
80 24 32
100

20 28
60
80 24
16
20
40 60
12
16

8 40 12
20
8
4
20

TM075229
4

TM075228
0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h] 0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
0 5 10 15 20 25 30 35 40 Q [US GPM]
0 5 10 15 20 25 30 35 40 Q [US GPM]

H H
[ft] [m] H H
45 SCALA1 3-45 [ft] [m]
140 SCALA1 5-25
40 28
120
35 80 24
100 30
20
80 25 60
16
20
60
15 40 12
40
10
8
20 20
5

TM075231
4
TM075230

0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h] 0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
0 5 10 15 20 25 30 35 40 Q
45 [US GPM]
0 5 10 15 20 25 30 35 40 45 50 Q [US GPM]
H H
[ft] [m]
180 55 SCALA1 5-55
50
160
45
140
40
120
35

100 30

80 25

20
60
15
40
10
20 5
TM084518

TM075232
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Q [m³/h]

0 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]

21
5 SCALA

Technical data
SCALA1 twin booster system

Dimensions

L2 L1

H3

H1
H2

TM075401
W1

Dimensions of SCALA1 twin system

H1 H2 H3 L1 L2 W1
Pos. [mm] [mm] [mm] [mm] [mm] [mm]
[inch] [inch] [inch] [inch] [inch] [inch]
360 210 92 614 360 473
SCALA1 twin system
14.2 8.3 3.6 24.2 14.2 18.6

Construction of SCALA1 twin system

1 2

TM075400

SCALA1 twin system

Pos. Component Material


1 Inlet and outlet manifolds Composite
2 Isolating valves Brass
3 Twin base plate Composite

22
SCALA
6

SCALA2
6. SCALA2
Self-priming
A self-priming pump ensures a stable operation, even if
the pump is not fully filled with liquid. The self-priming
pump is able to lift liquid from below the inlet level and
handle a mix of air and liquid until the pump reaches a
fully-primed pumping condition.

Robust design
The pump is designed for long and trouble-free
operation.Aluminium construction combined with excellent
corrosion-resistant internal components ensure high
robustness in operation.

Easy installation
All-in-one fully integrated plug-and-pump solution
eliminating any uncertainties found in traditional
TM075409
installations.

Protection features
SCALA2 pump
Dry-running protection
The product incorporates dry-running protection that
Grundfos SCALA2 is a fully integrated, self-priming, automatically stops the pump from running without
compact waterworks for pressure boosting in domestic liquid. Dry-running protection means less risk of pump
applications. damage and lower maintenance costs.
SCALA2 incorporates integrated speed control, enabling
Anti-cycling function
the ability to keep perfect pressure in the taps, which
means that the pump performance will adjust to the The anti-cycling function prevents the product from
increasing demand. starting and stopping too often in case of a minor leakage
in the system or if a tap has not been closed completely.
The anti-cycling function will stop the pump, and an alarm
Motor will be indicated.
The highly efficient motor with a permanent magnet is
water-cooled and equipped with sealed, greased-for-life Maximum runtime
ball bearings to ensure silent operation and minimum The maximum runtime function is a timer that can turn the
service. pump off if it runs continuously for a certain amount of
It has a built-in thermal switch and requires no additional time. For SCALA2, this time period is 30 minutes.
motor protection.

Features and benefits of SCALA2


• Perfect water pressure.
• All-in-one integrated booster.
• High energy efficiency.
• Easy selection.
• Compact.
• Low noise < 47 dB(A) with typical use.

Perfect water pressure


SCALA2 is equipped with an integrated sensor that
measures the pressure discharged from the pump. The
sensor sends a signal to the pump control and compares
the measured pressure level with the desired pressure
level, which is the pressure set according to the
homeowner's needs.
If there is a difference between these two measurements,
the pump control signals the frequency converter to
increase or decrease the pump speed, thus maintaining a
constant pressure in the system.

23
6 SCALA

Performance curves
SCALA2

50/60 Hz

TM1040350
SCALA2 3-45 performance curves

24
SCALA
6

Technical data

SCALA2
Dimensions and weights

H1

H2
H3
B1 L1

TM063305
Dimensions of SCALA2

H1 H2 H3 L1 B1 Weight
Pos. [mm] [mm] [mm] [mm] [mm] [kg]
[inch] [inch] [inch] [inch] [inch] [lb]
302 234 114 403 193 10
SCALA2
11.9 9.2 4.5 15.9 7.6 22

Operating conditions

SCALA2 3-45
45 °C
Max. ambient temperature, 60 Hz models
(113 °F)
55 °C
Max. ambient temperature for 1 x 200-240 V, 50 Hz models
(131 °F)
45 °C
Max. liquid temperature
(113 °F)
Maximum system pressure [bar (psi)] 10 (145)
Max. inlet pressure [bar (psi)] 6 (87)
Max. head [m (ft)] 45 (147)
Nominal head [m (ft)] 27 (88.6)
Nominal flow [m3/h (GPM)] 3 (13.21)
IP Rating X4D (Outdoor installation)
Pumped liquids Clean, fresh water and chlorinated water < 300 ppm
Noise level [db(A)] < 47

Electrical data

50/60 Hz
Voltage and frequency P1 P2 n In
Insulation class
[V] ([Hz]) [W (hp)] [W (hp)] [rpm] [A]
1 x 200-240 (50/60)
550 450
1 x 208-230 (60) 5200 2.80 F
(0.74) (0.60)
1 x 115 (60)

25
6 SCALA

Construction of SCALA2
SCALA2

TM063306
Exploded view of SCALA2

Material specification
Pos. Component Material
Aluminium, Composite and
1 Combined pump and stator housing
EN 1.4301 / AISI 304
2 Control box cover Composite
3 Pump cover Composite
4 Shaft seal Carbon/Ceramic
5 Chamber stack (four stages) Composite
9 Non-return valve, outlet Composite
Composite, Butyl and
10 Pressure tank complete
EN 1.4301 / AISI 304
11 Connection part Composite
19 Drain plug Composite
22 Thread R 1" / NPT 1" Composite
24 Non-return valve, inlet Composite

26
SCALA
6

Approvals and markings

SCALA2
Safety approvals

PS

Drinking water approvals

ACS
Combined

WATER QUALITY
Drinking water system component
Water circulation pump NSF/ANSI 61
99K4 MH26400
NSF/ANSI 372

Suction performance

H H
[ft] [m]
150 46 SCALA2
44
140
42

130 40

38
120
36

34
110
32
100
30

28
90
26
80 24

22
70
20
60 18

16
50
14

40 12

10
30
8
1m
20 6
3m 2m
4 8m
4m
10 5m
2 6m
7m
TM066277

0 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 4.2 Q [m³/h]

0 2 4 6 8 10 12 14 16 18 Q [US GPM]

Suction performance for SCALA2

27
7 SCALA
Accessories

7. Accessories
SCALA twin accessory set Construction of SCALA twin accessory set

1 2

TM075392

TM075402
3
4
Twin accessory set 5

Exploded view of SCALA twin accessory set


When an installation requires a two-pump solution,
SCALA pumps can be easily connected using this set. It
includes all the necessary components to set up SCALA Pos. Component Material
pumps as a twin booster system. 1 Isolating valves Brass
This set includes: 2
Manifold cap with O-
Composite, NBR
ring
• base plate
Inlet and outlet
3 Composite
• two manifolds (inlet and outlet) including the isolating manifolds
valves 4 Communication cable -

• communication cable (for SCALA1 only) 5 Twin base plate Composite


6 Fixing screws Stainless steel
• fixing screws.

Product numbers
Valve Manifold
Description Part number
Connection Connection
SCALA1 twin accessory set 1" Rp 1 1/4" Rp 99725165
SCALA1 twin accessory set 1" NPT 1 1/4" NPT 99725168
SCALA2 twin accessory set 1" Rp 1 1/4" Rp 99743076
SCALA2 twin accessory set 1" NPT 1 1/4" NPT 99743075

28
SCALA
7

SCALA2 accessories Locking pin

Accessories
The pump may produce a clicking noise if there is positive
Flexible hoses pressure at the inlet of the pump. In this case, you can
mount a locking pin to avoid this noise. When a locking
pin is mounted, the self-priming function is not applicable.
If the pump has a negative pressure at the inlet, removing
the locking pin is necessary to enable the self-priming
function.
The pin is also available as an accessory.

Description Product number


Locking pin SCALA2 (20 pieces) 99862078

TM080290

The flexible hose range provides a safe and taint-free


conveyance of potable water supplies in domestic and
commercial applications. The range is designed to
achieve robust and flexible solutions with the following
attributes:
• Water Regulation Advisory Scheme (WRAS)-approved
for both hot and cold water
• Strong construction with excellent abrasion and crush-
resistant construction
• Excellent flexibility and kink resistance.

Product numbers
Description Product number
Flexible hose set 99891639
Flexible hose set (with brass elbow
99891647
connection)

29
7 SCALA

Inlet filter Filter specifications


Accessories

Micron rating 250


Efficiency percentage 80
Max. working pressure [bar (psi)] 8 (116)
Max. differential pressure [bar (psi)] 0.8 (11.6)
Max. working temperature 45 °C (113 °F)

TM075393
p P
[psi] [bar]

3.0
Inlet filter accessory 0.20

2.5
0.16

2.0
When using SCALA products for pumping rainwater or 0.12

well water, we recommend installing a filter on the inlet 1.5

side to provide clean water to increase the longevity of the 1.0


0.08

pump, and to protect it from sand, gravel or other debris.


0.04
Features of the filter include: 0.5

• Clean water provides long life for the pump. 0.0 0.00

TM075373
0 1 2 3 4 5 6 7 8 Q [m³/h]

• Quick and easy installation. 0 5 10 15 20 25 30 Q [US GPM]

• Easy maintenance and cleaning.


Inlet filter pressure loss
The square mesh allows a uniform flow along the entire
surface of the cartridge itself, which minimizes the
possibility of clogging. Also, the smooth surface of the Product numbers
filter ensures easy washing and cleaning. The filter
cartridges provide a nominal filtration with an efficiency of Description Connection Part number
80 %. If properly used, they can be used repeatedly Inlet filter, 250 micron 1" Rp 99725183
maintaining constant efficiency. Inlet filter, 250 micron 1" NPT 99725185
The inside core is manufactured from talc-filled
polypropylene and a welded nylon net. The filter housing
is composite.

30
SCALA
8

Product numbers
8. Product numbers
Guide on how to read the product number tables
Abbreviation Description
SNI Warranty card for Indonesia is included.
Printed installation and operating instructions in English (GB) and Arabic are
ARB
included.
CCC CCC approval on the nameplate.
CSA CSA approval on the nameplate.

SCALA1
50 Hz
Pump model Voltage Plug type/cable Country of origin Product number
SCALA1 3-25 1 x 230 V 50 Hz Schuko Hungary 99530403
SCALA1 3-35 1 x 230 V 50 Hz Schuko Hungary 99530404
SCALA1 3-45 1 x 230 V 50 Hz Schuko Hungary 99530405
SCALA1 5-25 1 x 230 V 50 Hz Schuko Hungary 99530406
SCALA1 5-55 1 x 230 V 50 Hz Schuko Hungary 99530407

SCALA1 3-25 1 x 230 V 50 Hz No plug Hungary 99530408


SCALA1 3-35 1 x 230 V 50 Hz No plug Hungary 99530409
SCALA1 3-45 1 x 230 V 50 Hz No plug Hungary 99530410
SCALA1 5-25 1 x 230 V 50 Hz No plug Hungary 99530411
SCALA1 5-35 1 x 230 V 50 Hz No plug Hungary 92929476
SCALA1 5-55 1 x 230 V 50 Hz No plug Hungary 99530412

SCALA1 3-25 1 x 230 V 50 Hz Thailand Hungary 99530413


SCALA1 3-35 1 x 230 V 50 Hz Thailand Hungary 99530414
SCALA1 3-45 1 x 230 V 50 Hz Thailand Hungary 99530415
SCALA1 5-25 1 x 230 V 50 Hz Thailand Hungary 99530416
SCALA1 5-55 1 x 230 V 50 Hz Thailand Hungary 99530417

SCALA1 3-25 1 x 230 V 50 Hz Australia Hungary 99530418


SCALA1 3-35 1 x 230 V 50 Hz Australia Hungary 99530419
SCALA1 3-45 1 x 230 V 50 Hz Australia Hungary 99530420
SCALA1 5-25 1 x 230 V 50 Hz Australia Hungary 99530421
SCALA1 5-55 1 x 230 V 50 Hz Australia Hungary 99530422

SCALA1 3-25 1 x 230 V 50 Hz UK Hungary 99530423


SCALA1 3-35 1 x 230 V 50 Hz UK Hungary 99530424
SCALA1 3-45 1 x 230 V 50 Hz UK Hungary 99530425
SCALA1 5-25 1 x 230 V 50 Hz UK Hungary 99530426
SCALA1 5-55 1 x 230 V 50 Hz UK Hungary 99530427

SCALA1 3-25 SNI 1 x 230 V 50 Hz Schuko Hungary 99530428


SCALA1 3-35 SNI 1 x 230 V 50 Hz Schuko Hungary 99530429
SCALA1 3-45 SNI 1 x 230 V 50 Hz Schuko Hungary 99530430
SCALA1 5-25 SNI 1 x 230 V 50 Hz Schuko Hungary 99530431
SCALA1 5-55 SNI 1 x 230 V 50 Hz Schuko Hungary 99530432

SCALA1 3-25 1 x 230 V 50 Hz Argentina Hungary 99656462


SCALA1 3-35 1 x 230 V 50 Hz Argentina Hungary 99656484
SCALA1 3-45 1 x 230 V 50 Hz Argentina Hungary 99656485
SCALA1 5-25 1 x 230 V 50 Hz Argentina Hungary 99656486
SCALA1 5-55 1 x 230 V 50 Hz Argentina Hungary 99656487

31
8 SCALA

Pump model Voltage Plug type/cable Country of origin Product number


Product numbers

SCALA1 3-25 CCC 1 x 230 V 50 Hz No plug Hungary 99530433


SCALA1 3-35 CCC 1 x 230 V 50 Hz No plug Hungary 99530434
SCALA1 3-45 CCC 1 x 230 V 50 Hz No plug Hungary 99530435
SCALA1 5-25 CCC 1 x 230 V 50 Hz No plug Hungary 99530436
SCALA1 5-55 CCC 1 x 230 V 50 Hz No plug Hungary 99530437

60 Hz
Pump model Voltage Plug type/cable Country of origin Product number
SCALA1 3-25 ARB 1 x 230 V 60 Hz No plug Hungary 99530438
SCALA1 3-35 ARB 1 x 230 V 60 Hz No plug Hungary 99530439
SCALA1 3-45 ARB 1 x 230 V 60 Hz No plug Hungary 99530440
SCALA1 5-25 ARB 1 x 230 V 60 Hz No plug Hungary 99530441
SCALA1 5-55 ARB 1 x 230 V 60 Hz No plug Hungary 99530441

SCALA1 3-25 1 x 230 V 60 Hz No plug Hungary 99530443


SCALA1 3-35 1 x 230 V 60 Hz No plug Hungary 99530444
SCALA1 3-45 1 x 230 V 60 Hz No plug Hungary 99530445
SCALA1 5-25 1 x 230 V 60 Hz No plug Hungary 99530446
SCALA1 5-55 1 x 230 V 60 Hz No plug Hungary 99530447

SCALA1 3-25 CSA 1 x 230 V 60 Hz NEMA 6-15 Hungary 99631734


SCALA1 3-35 CSA 1 x 230 V 60 Hz NEMA 6-15 Hungary 99631735
SCALA1 3-45 CSA 1 x 230 V 60 Hz NEMA 6-15 Hungary 99631736
SCALA1 5-25 CSA 1 x 230 V 60 Hz NEMA 6-15 Hungary 99631737
SCALA1 5-55 CSA 1 x 230 V 60 Hz NEMA 6-15 Hungary 99631739

SCALA1 3-25 1 x 115 V 60 Hz No plug Hungary 99530448


SCALA1 3-35 1 x 115 V 60 Hz No plug Hungary 99530449
SCALA1 3-45 1 x 115 V 60 Hz No plug Hungary 99530450
SCALA1 5-25 1 x 115 V 60 Hz No plug Hungary 99530451
SCALA1 5-55 1 x 115 V 60 Hz No plug Hungary 99530452

SCALA1 3-25 CSA 1 x 115 V 60 Hz NEMA 5-15 Hungary 99631740


SCALA1 3-35 CSA 1 x 115 V 60 Hz NEMA 5-15 Hungary 99631741
SCALA1 3-45 CSA 1 x 115 V 60 Hz NEMA 5-15 Hungary 99631742
SCALA1 5-25 CSA 1 x 115 V 60 Hz NEMA 5-15 Hungary 99631753
SCALA1 5-55 CSA 1 x 115 V 60 Hz NEMA 5-15 Hungary 99631754

32
SCALA
8

SCALA2

Product numbers
50/60 Hz
Pump model Voltage Plug type/cable Country of origin Product number
SCALA2 3-45 1 x 230 V 50/60 Hz Schuko Serbia 98562862
SCALA2 3-45 1 x 230 V 50/60 Hz Schuko Serbia 99027073
SCALA2 3-45 SNI 1 x 230 V 50/60 Hz Schuko Serbia 99027077
SCALA2 3-45 CCC 1 x 230 V 50/60 Hz No plug Serbia 98562863
SCALA2 3-45 1 x 230 V 50/60 Hz No plug Serbia 98562865
SCALA2 3-45 1 x 230 V 50/60 Hz No plug Serbia 99027076
SCALA2 3-45 ARB 1 x 230 V 50/60 Hz No plug Serbia 99448121
SCALA2 3-45 1 x 230 V 50/60 Hz Australia Serbia 98562866
SCALA2 3-45 1 x 230 V 50/60 Hz UK Serbia 98562870
SCALA2 3-45 1 x 230 V 50/60 Hz Argentina Serbia 98562872
SCALA2 3-45 1 x 230 V 50/60 Hz Chile Serbia 99342334
SCALA2 3-45 1 x 230 V 50/60 Hz Thailand Serbia 99371163
SCALA2 3-45 1 x 230 V 50/60 Hz India Serbia 99471149
SCALA2 3-45 CSA 1 x 230 V 50/60 Hz US Serbia 98562817

SCALA2 3-45 CSA 1 x 115 V 50/60 Hz US Serbia 98562818


SCALA2 3-45 1 x 115 V 50/60 Hz No plug Serbia 99027074
SCALA2 3-45 1 x 115 V 50/60 Hz US Serbia 99027075
SCALA2 3-45 1 x 115 V 50/60 Hz Japan Serbia 99240350

33
9 SCALA
Grundfos Product Center

9. Grundfos Product Center


Online search and sizing tool to help you make the right choice.
From the international view, you can select your specific country to view the product range available to you.
International view: http://product-selection.grundfos.com

All the information you need in one place


Performance curves, technical specifications, pictures, dimensional drawings, motor curves, wiring
diagrams, spare parts, service kits, 3D drawings, documents, system parts. The Product Center
displays any recent and saved items - including complete projects - right on the main page.
Downloads
On the product pages, you can download installation and operating instructions, data booklets,
service instructions, etc., in PDF format.

When you select your country, you will see the menus below. Note that some menus may not be available depending on
the country.
Example: https://product-selection.grundfos.com/uk

Pos. Description
1 Products & services enables you to find products and documents by typing a product number or name into the search field.
2 Applications enables you to choose an application to see how Grundfos can help you design and optimise your system.
3 Products A-Z enables you to look through a list of all the Grundfos products.
4 Categories enables you to look for a product category.
5 Liquids enables you to find pumps designed for aggressive, flammable or other special liquids.
6 Product replacement enables you to find a suitable replacement.
7 WWW enables you to select the country, which changes the language, the available product range and the structure of the website.
8 Sizing enables you to size a product based on your application and operating conditions.

34
99735562
ECM: 1366409

www.grundfos.com
Tel: +45 87 50 14 00
DK-8850 Bjerringbro
04.2023

Poul Due Jensens Vej 7


GRUNDFOS Holding A/S
Trademarks displayed in this material, including but not limited to Grundfos and the Grundfos logo, are registered trademarks owned by The Grundfos Group. © 2023 Grundfos Holding A/S, all rights reserved.