Scala 1-2 DataBooklet
Scala 1-2 DataBooklet
Scala 1-2 DataBooklet
SCALA
Multistage centrifugal boosters, 50/60 Hz
SCALA
1. Product introduction . . . . . . . . . . . . . . . . . . . 3
Table of contents
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Features and benefits . . . . . . . . . . . . . . . . . . . . .3
Pumped liquids. . . . . . . . . . . . . . . . . . . . . . . . . .3
Product range. . . . . . . . . . . . . . . . . . . . . . . . . . .4
Performance range . . . . . . . . . . . . . . . . . . . . . . .5
2. Selection guide . . . . . . . . . . . . . . . . . . . . . . . 6
4. SCALA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Product range. . . . . . . . . . . . . . . . . . . . . . . . . . 12
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Features and benefits of SCALA1 . . . . . . . . . . . . 12
Protection features . . . . . . . . . . . . . . . . . . . . . . 12
Performance curves . . . . . . . . . . . . . . . . . . . . . 13
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 15
Approvals and markings . . . . . . . . . . . . . . . . . . 18
Suction performance . . . . . . . . . . . . . . . . . . . . . 19
6. SCALA2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Features and benefits of SCALA2 . . . . . . . . . . . . 23
Protection features . . . . . . . . . . . . . . . . . . . . . . 23
Performance curves . . . . . . . . . . . . . . . . . . . . . 24
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 25
Approvals and markings . . . . . . . . . . . . . . . . . . 27
Suction performance . . . . . . . . . . . . . . . . . . . . . 27
7. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 28
SCALA twin accessory set . . . . . . . . . . . . . . . . . 28
SCALA2 accessories. . . . . . . . . . . . . . . . . . . . . 29
8. Product numbers . . . . . . . . . . . . . . . . . . . . . 31
SCALA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SCALA2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
2
SCALA
1
Product introduction
1. Product introduction
Features and benefits
General benefits of SCALA pumps:
• Easy installation.
• Easy commission.
• Easy operation.
TM075413
Self-priming √ √
Alarm indication √ √
Dry-running protection √ √
Left to right: SCALA1, SCALA2 Anti-cycling protection √ √
Maximum runtime
√ √
protection
Grundfos SCALA pumps are all-in-one integrated
pressure boosters designed for domestic use and ensure Bluetooth
√ -
communication
a constant supply of clean water to households, gardens
and light commercial applications. Twin enabled √ -
External input √ -
Adjustable constant
SCALA1 pressure
- √
Grundfos SCALA1 is a self-priming, multistage pump, Integrated frequency
which combines all the components of a pressure booster - √
converter
into a compact composite enclosure. Low noise 55 dB(A) 47 dB(A)
SCALA1 can communicate with Grundfos GO Remote
app through a built-in Bluetooth technology, which Pumped liquids
enables high customization options, making this pump a
good fit for every application. The product is suitable for pumping clean, thin, non-
aggressive and non-explosive liquids without solid
particles or fibres.
SCALA2 The product is designed for fresh water with a maximum
Grundfos SCALA2 is a fully integrated, self-priming, chloride content of 300 ppm and a free chlorine content
compact waterworks for pressure boosting in domestic below 1 ppm.
applications. Examples of liquids:
SCALA2 incorporates integrated speed control which
allows maintaining a perfect pressure in the taps. This • drinking water
means that the pump performance will adjust to the the • rainwater.
increasing demand.
Applications
The SCALA boosters are suitable for domestic and light
commercial water supply, where pressure boosting is
required.
We recommend SCALA pumps for the following
applications:
• pressure boosting of city mains water
• pressure boosting of water from roof tank
• pressure boosting of water from break tank
• pressure boosting of water from ground tank
• water supply from shallow wells [8 m (26.2 ft)]
• garden irrigation
• water transfer.
3
1 SCALA
Product range
Product introduction
4
SCALA
1
Performance range
Product introduction
The performance curves show the range of the SCALA
pumps.
H H
[ft] [m]
SCALA1
180 55 60 Hz
50
160
5-55
45
140
40
3-45
120
35
100 30
3-35
80 25
20
60
3-25
15
40
10
20
5
5-25
TM075223
TM075369
0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 Q [m³/h]
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [US GPM]
TM1040464
5
2 SCALA
Selection guide
2. Selection guide
This guide helps you to size and select the most suitable SCALA product.
Follow the instructions below to determine which product variant is best suited to your needs.
City water mains Due to integrated frequency converter, SCALA2 can adapt the speed to varying
SCALA2 ● ● ● water pressure in the city mains, delivering constant pressure in all taps any time.
PN10 rating ensures robustness towards maximum system pressure.
SCALA1 construction offers better suction capabilities with different modes to handle
SCALA1 ● ● ●
Shallow well air.
SCALA2 ● ●
SCALA1 ● ●
Water storage tank (above
ground level) Adjustable constant pressure for SCALA2 enables user to select the desired
SCALA2 ● ● ●
pressure for the entire home, and thus avoids overpressure.
SCALA1 construction offers better suction capabilities with different modes to handle
Water storage tank (below SCALA1 ● ● ●
air.
ground level)
SCALA2 ● ●
SCALA1 ● ●
Roof tank Adjustable constant pressure for SCALA2 enables user to select the desired
SCALA2 ● ● ●
pressure for the entire home, and thus avoids overpressure.
External input and fixed speed in SCALA1 will make sure water is transferred as
SCALA1 ● ● ●
Water transfer quickly as possible from point A to B, when needed.
SCALA2 ●
External input and calendar function are a perfect combination for irrigation
SCALA1 ● ● ●
Garden irrigation purposes.
SCALA2 ●
SCALA1 ● ●
Kitchen
SCALA2 ● ● ● SCALA2 delivers constant pressure to all taps regardless of the inlet pressure.
SCALA1 ● ●
Bathroom
SCALA2 ● ● ● SCALA2 delivers constant pressure to all taps regardless of the inlet pressure.
Number of floors 1-5 taps 6-10 taps 11-20 taps 21-50 taps
SCALA1 3-45 or
4 SCALA1 5-55 SCALA1 Twin 5-55 SCALA1 Twin 5-55
SCALA2 3-45
SCALA1 3-45 or SCALA1 3-45 or
3 SCALA1 5-55 SCALA1 Twin 5-55
SCALA2 3-45 SCALA2 3-45
SCALA1 3-35 or SCALA1 3-45 or SCALA1 5-55 or SCALA1 Twin 5-55 or
2
SCALA2 3-45 SCALA2 3-45 SCALA1 5-35 SCALA1 5-35
SCALA1 3-25 or SCALA1 3-35 or SCALA1 3-45 or SCALA1 Twin 5-55 or
1
SCALA2 3-45 SCALA2 3-45 SCALA2 3-45 SCALA1 5-35
Preconditions:
• A tap pressure of 3 bar (43.5 psi) is considered. To achieve pressure of 4 bar (58 psi), remove two floors.
• The inlet is flooded. For suction operation, remove a floor for every 3 metres (9.84 ft) of suction depth.
• A tap flow between 9 (2.4 gpm) and 12 l/min (3.2 gpm) average usage and half of the taps opened at the same time
will be considered.
6
SCALA
3
TM040338
on the geodetic suction lift. The recommended maximum
length of the inlet pipe according to the suction lift is
shown in the figure below. The example shows that if the
suction lift is 2.5 m (8.2 ft), the length of the inlet pipe Recommended pipe installation to avoid friction and air
must not exceed 25 m (82 ft). pockets
[ft] [m]
9
8
25
7
20 6
5
15
4
10 3
2
TM075387
5
1
0
4 8 12 16 20 24 28 32 36 40 [m]
[ft] Correct pipe sizing for connection to the pump inlet or
15 45 75 105 120 outlet
TM075339
7
3 SCALA
8
SCALA
3
2
3 3 4
1
5
A
6
7
TM075007
H1
5 4
8
Pos. Description
1 Highest tapping point
H2
6
TM075006
2 Pipe hangers
3 Isolating valve
4 Flexible hoses
5 Drain to sewer
Pos. Description
6 Inlet filter
1 Highest tapping point
7 Freshwater tank
2 Isolating valve
8 Foot valve with strainer
3 Flexible hoses
9 Minimum 1-degree inclination
4 Pipe support
5 Inlet filter
6 Foot valve with strainer
H1 Maximum suction lift: 8 m (26.2 ft)
H2 Inlet pipe must be submerged at least 0.5 m (1.64 ft)
9
3 SCALA
Mains water pressure boosting, SCALA1 Mains water pressure boosting, SCALA2
Installation and operation
1 1
2 2
7 3 9 4
7 3 9 4
10
10
5 6
2 5 6 2
8
8
TM075262
TM064347
3
3
Mains water pressure boosting, SCALA1 Mains water pressure boosting, SCALA2
10
SCALA
3
Roof tank filling Electrical connection
4
TM075330
Pos. Description
1 Float switch
2 External input (switch) cable
3 Pump
4 Water source (tank)
5 Roof tank
11
4 SCALA
SCALA1
4. SCALA1
Self-priming
A self-priming pump ensures a stable operation, even if
the pump is not fully filled with liquid. The self-priming
pump is able to lift liquid from below the inlet level and
handle a mix of air and liquid until the pump reaches a
fully-primed pumping condition.
Robust design
The pump is designed for long and trouble-free
operation.Composite construction combined with excellent
corrosion-resistant internal components ensure high
robustness in operation.
Easy installation
TM075390
All-in-one fully integrated plug-and-pump solution
eliminating any uncertainties found in traditional
SCALA1 pump installations.
Protection features
Grundfos SCALA1 is a self-priming, multistage pump,
which combines all of the components of a pressure Dry-running protection
booster into a compact composite enclosure. The product incorporates dry-running protection that
SCALA1 can communicate with the Grundfos GO Remote automatically stops the pump from running without
app through a built-in Bluetooth technology, which liquid. Dry-running protection means less risk of pump
enables high customization options, making this pump a damage and lower maintenance costs.
good fit for every application.
Anti-cycling function
Product range The anti-cycling function prevents the product from
starting and stopping too often in case of a minor leakage
Nominal flow rate Max. head in the system or if a tap has not been closed completely.
Pump type
[m3/h (gpm)] [m (ft)] The anti-cycling function will stop the pump, and an alarm
SCALA1 3-25 3 (13) 25 (82)
will be indicated.
SCALA1 3-35 3 (13) 35 (114) Maximum runtime
SCALA1 3-45 3 (13) 45 (147) The maximum runtime function is a timer that can turn the
SCALA1 5-25 5 (22) 25 (82) pump off if it runs continuously for a certain amount of
SCALA1 5-35 5 (22) 55 (180) time. This time period is adjustable via Grundfos GO
SCALA1 5-55 5 (22) 55 (180) Remote app.
Motor
The motor is water-cooled and equipped with sealed,
greased-for-life ball bearings to ensure silent operation
and minimum service. The motor has a built-in thermal
switch and requires no additional motor protection.
12
SCALA
4
Performance curves
SCALA1
50 Hz 60 Hz
H H H H
[ft] [m] [ft] [m]
SCALA1 3-25 SCALA1 3-25
28 28
90 50 Hz 90 60 Hz
80 24 80 24
70 70
20 20
60 60
16 16
50 50
40 12 40 12
30 30
8 8
20 20
4 4
10 10
0 0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 Q [m³/h]
TM075364
200
0.2 0.2
100 100
0.0 0 0.0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 Q [m³/h]
H H H H
[ft] [m] [ft] [m]
40
SCALA1 3-35 120 SCALA1 3-35
50 Hz 35
60 Hz
120
35
100 30
100 30
80 25
80 25
20
20 60
60
15
15
40
40
10 10
20 20
5 5
0 0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Q [m³/h]
TM075365
TM075219
0.4
200 200
0.2 0.2
0.0 0 0.0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Q [m³/h]
H H H H
[ft] [m] [ft] [m]
45 SCALA1 3-45 45 SCALA1 3-45
140 50 Hz 140 60 Hz
40 40
120 120
35 35
100 30 100 30
80 25 25
80
20 20
60 60
15 15
40 40
10 10
20 20
5 5
0 0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 Q [m³/h]
0.4 0.4
200 200
0.2 0.2
0.0 0 0.0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h] 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 Q [m³/h]
13
4 SCALA
50 Hz 60 Hz
SCALA1
H H H H
[ft] [m] [ft] [m]
SCALA1 5-25 SCALA1 5-25
100 100
30 60 Hz 30 60 Hz
80 25 80 25
20 20
60 60
15 15
40 40
10 10
20 20
5 5
0 0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Q [m³/h] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Q [m³/h]
0.6 0.6
400 400
TM075367
TM075367
0.4 0.4
200 200
0.2 0.2
0.0 0 0.0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Q [m³/h] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Q [m³/h]
Not available
TM084369
H H H H
[ft] [m] [ft] [m]
180 55 SCALA1 5-55 180 55 SCALA1 5-55
50 50 Hz 50 60 Hz
160 160
45 45
140 140
40 40
120 120
35 35
100 30 100 30
80 25 80 25
20 20
60 60
15 15
40 40
10 10
20 5 20 5
0 0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 Q [m³/h] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 Q [m³/h]
14
SCALA
4
Technical data
SCALA1
Dimensions and weights
DN2
DN1
H1
H2
H3
TM075267
W1 L1
H1 H2 H3 L1 W1
Pos. [mm] [mm] [mm] [mm] [mm]
[inch] [inch] [inch] [inch] [inch]
316 263 171 466 202
SCALA1 (all variants)
12.4 10.4 6.7 18.4 8.0
Weight
SCALA1 3-25 SCALA1 3-35 SCALA1 3-45 SCALA1 5-25 SCALA1 5-35 SCALA1 5-55
[kg] [kg] [kg] [kg] [kg] [kg]
[lb] [lb] [lb] [lb] [lb] [lb]
11 12 12 12 12 14
24.2 26.4 26.4 26.4 26.4 30.8
Operating conditions
SCALA1
3-25 3-35 3-45 5-25 5-35 5-55
55 °C 55 °C 55 °C 55 °C 55 °C 55 °C
Max. ambient temperature
(131 °F) (131 °F) (131 °F) (131 °F) (131 °F) (131 °F)
45 °C 45 °C 45 °C 45 °C 45 °C 45 °C
Max. liquid temperature
(113 °F) (113 °F) (113 °F) (113 °F) (113 °F) (113 °F)
Maximum system pressure [bar
8 (116) 8 (116) 8 (116) 8 (116) 8 (116) 8 (116)
(psi)]
Maximum inlet pressure [bar
5 (72.5) 4 (58) 3 (43.5) 5 (72.5) 4 (58) 2 (29)
(psi)]
Max. head [m (ft)] 50 Hz 25 (82) 36 (118.1) 44 (144.3) 26 (85.3) 40 (131.2) 52 (170.6)
Max. head [m (ft)] 60 Hz 25 (82) 35 (114.8) 46 (150) 27 (85.3) - 55 (180)
Nominal head [m (ft)] 15 (49.2) 20 (65.6) 25 (82) 15 (49.2) 20 (65.6) 25 (82)
Nominal flow [m3/h (gpm)] 3.00 (12.19) 3.72 (16.38) 3.59 (15.80) 4.80 (21.12) 4.92 (21.66) 5.33 (23.48)
IP Rating X4D X4D X4D X4D X4D X4D
Pumped liquids Clean water Clean water Clean water Clean water Clean water Clean water
Noise level [db(A)] < 55 < 55 < 55 < 55 < 55 < 55
Frequency of starts and stops 25 per hour 25 per hour 25 per hour 25 per hour 25 per hour 25 per hour
Start pressure (pstart) [bar (psi)] 1.2 (17.4) 1.5 (21.8) 2.2 (31.9) 1.2 (17.4) 1.5 (21.7) 2.8 (40.6)
15
4 SCALA
Electrical data
SCALA1
50 Hz
Voltage P1 P2 n In Istart Standby power
Pump type
[V] [W (hp)] [W (hp)] [rpm] [A] [A] [W]
SCALA1 3-25 1 x 230 550 (0.74) 360 (0.50) 2850 2.58 13.0 1.5
SCALA1 3-35 1 x 230 720 (0.97) 450 (0.60) 2800 3.27 13.0 1.5
SCALA1 3-45 1 x 230 910 (1.23) 580 (0.80) 2800 4.10 17.0 1.5
SCALA1 5-25 1 x 230 650 (0.88) 425 (0.60) 2850 3.00 13.0 1.5
SCALA1 5-35 1 x 230 890 (1.19) 450 (0.60) 2800 3.60 20.0 1.5
SCALA1 5-55 1 x 230 1200 (1.62) 780 (1.00) 2850 5.38 26.0 1.5
60 Hz
Voltage P1 P2 n In Istart Standby power
Pump type
[V] [W (hp)] [W (hp)] [rpm] [A] [A] [W]
1 x 230 540 (0.72) 350 (0.50) 3450 2.37 13.0 1.5
SCALA1 3-25
1 x 115 560 (0.75) 350 (0.50) 3450 5.10 29.5 1.5
1 x 230 650 (0.88) 470 (0.60) 3400 2.76 13.0 1.5
SCALA1 3-35
1 x 115 650 (0.88) 470 (0.60) 3400 5.71 29.5 1.5
1 x 230 870 (1.17) 570 (0.80) 3350 3.72 15.5 1.5
SCALA1 3-45
1 x 115 950 (1.28) 590 (0.80) 3400 8.62 40.0 1.5
1 x 230 600 (0.80) 420 (0.60) 3450 2.60 13.0 1.5
SCALA1 5-25
1 x 115 610 (0.82) 450 (0.60) 3450 5.70 29.5 1.5
1 x 230 1250 (1.68) 810 (1.10) 3450 5.25 22.5 1.5
SCALA1 5-55
1 x 115 1250 (1.68) 860 (1.10) 3450 11.57 64.0 1.5
16
SCALA
4
Construction of SCALA1
SCALA1
5
15
10
11 6
8
9
18
14 13
12
16
TM075375
17
Material specification
Pos. Component Material
1 Combined pump and stator housing Composite
4 PCB cover Composite
5 Cover for control box Composite
7 Motor flange Composite
8 Shaft seal, complete Carbon/Ceramic
9 Chamber stack Composite
11 Air handling unit Composite
14 Connection part for hydraulic Composite
15 Non-return valve discharge Composite
16 Cover for hydraulic Composite
17 Drain plug Composite
18 Fittings, thread R 1" / NPT 1" Composite
17
4 SCALA
Safety approvals
TM074611
TM074115
TM075405
ACS TM074613
TM074116
18
SCALA
4
Suction performance
SCALA1
H H H H
[ft] [m] [ft] [m]
26 SCALA1 SCALA1
80 3-25 40 3-35
24
120
22 35
70
20
100 30
60 18
16 25
50 80
14
40 12 20
60
10
30 15
8 40
0m
20 6 10
7m 6m 1m
4 8m 5m 20
10 2m 5
2
4m 8m 7m 6m 5m 4m 0m
3m
3m 2m 1m
0 0 0 0
TM075531
TM075532
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
Q [m³/h] Q [m³/h]
H H H H
[ft] [m] [ft] [m]
45
SCALA1 26 SCALA1
140 3-45 80 24 5-25
40 22
70
120 20
35
60 18
100 30
16
50
80 25 14
40 12
20
60 10
30
15 8
40
10 20 6
6m 5m 4m 1m
8m 7m 2m 0m
7m 4
20 6m 0m 10 3m
5 5m
8m 4m 1m 2
3m 2m
0 0 0 0
TM075533
TM075534
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
Q [m³/h] Q [m³/h]
H H
[ft] [m]
180 55 SCALA1
5-55
50
160
45
140
40
120
35
100 30
80 25
20
60
15
40
10
20 5 1m
8m 7m 6m 5m 4m 2m 0m
3m
0 0
0 1 2 3 4 5 6 7 8
TM075535
Q [m³/h]
TM084481
0 5 10 15 20 25 Q [US GPM]
19
5 SCALA
SCALA1 twin booster system
Protection features
TM075391 SCALA1 twin booster has all the protective functions of
the SCALA1 pump.
Dry-running protection will stop each pump separately,
SCALA1 twin booster system
while the anti-cycling protection and maximum runtime
protection will stop the system.
SCALA1 can be easily setup as a twin booster, in case
there is a need for a stand-by pump or higher flow Operating modes
demand.
Duty/Assist
For this purpose, there is a dedicated accessory set that
includes: In Duty/Assist, both pumps can run at the same time,
delivering more flow on the outlet side.
• base plate
If one pump is unable to meet the demand, the second
• inlet and outlet manifolds with valves pump will start up.
• communication cable Duty/Standby
• fixing screws. In this mode, only one pump will run at a time, while the
In the twin setup, the two SCALA1 pumps communicate other pump will remain as a standby pump.
together via a cable included in the accessory kit, Based on alternation settings, the pumps will switch
enabling optimum double-pump operation. priority in starting.
Easy installation
SCALA1 twin booster can be quickly installed. After the
pumps are mounted on the base plate and connected with
a cable and manifolds, it is only a matter of connecting to
the pipe system.
Once the system is primed, it is ready to deliver water.
Alternation
Once the communication cable is connected and the
system powered on, the pumps are automatically
assigned a priority at the start.
Alternation determines when the pumps will switch priority
in starting, enabling equal use during operation lifetime.
Grundfos GO Remote allows selecting the following
options:
• alternate on runtime
• alternate on the number of starts.
20
SCALA
5
Performance curves
20 28
60
80 24
16
20
40 60
12
16
8 40 12
20
8
4
20
TM075229
4
TM075228
0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h] 0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
0 5 10 15 20 25 30 35 40 Q [US GPM]
0 5 10 15 20 25 30 35 40 Q [US GPM]
H H
[ft] [m] H H
45 SCALA1 3-45 [ft] [m]
140 SCALA1 5-25
40 28
120
35 80 24
100 30
20
80 25 60
16
20
60
15 40 12
40
10
8
20 20
5
TM075231
4
TM075230
0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h] 0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
0 5 10 15 20 25 30 35 40 Q
45 [US GPM]
0 5 10 15 20 25 30 35 40 45 50 Q [US GPM]
H H
[ft] [m]
180 55 SCALA1 5-55
50
160
45
140
40
120
35
100 30
80 25
20
60
15
40
10
20 5
TM084518
TM075232
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Q [m³/h]
0 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]
21
5 SCALA
Technical data
SCALA1 twin booster system
Dimensions
L2 L1
H3
H1
H2
TM075401
W1
H1 H2 H3 L1 L2 W1
Pos. [mm] [mm] [mm] [mm] [mm] [mm]
[inch] [inch] [inch] [inch] [inch] [inch]
360 210 92 614 360 473
SCALA1 twin system
14.2 8.3 3.6 24.2 14.2 18.6
1 2
TM075400
22
SCALA
6
SCALA2
6. SCALA2
Self-priming
A self-priming pump ensures a stable operation, even if
the pump is not fully filled with liquid. The self-priming
pump is able to lift liquid from below the inlet level and
handle a mix of air and liquid until the pump reaches a
fully-primed pumping condition.
Robust design
The pump is designed for long and trouble-free
operation.Aluminium construction combined with excellent
corrosion-resistant internal components ensure high
robustness in operation.
Easy installation
All-in-one fully integrated plug-and-pump solution
eliminating any uncertainties found in traditional
TM075409
installations.
Protection features
SCALA2 pump
Dry-running protection
The product incorporates dry-running protection that
Grundfos SCALA2 is a fully integrated, self-priming, automatically stops the pump from running without
compact waterworks for pressure boosting in domestic liquid. Dry-running protection means less risk of pump
applications. damage and lower maintenance costs.
SCALA2 incorporates integrated speed control, enabling
Anti-cycling function
the ability to keep perfect pressure in the taps, which
means that the pump performance will adjust to the The anti-cycling function prevents the product from
increasing demand. starting and stopping too often in case of a minor leakage
in the system or if a tap has not been closed completely.
The anti-cycling function will stop the pump, and an alarm
Motor will be indicated.
The highly efficient motor with a permanent magnet is
water-cooled and equipped with sealed, greased-for-life Maximum runtime
ball bearings to ensure silent operation and minimum The maximum runtime function is a timer that can turn the
service. pump off if it runs continuously for a certain amount of
It has a built-in thermal switch and requires no additional time. For SCALA2, this time period is 30 minutes.
motor protection.
23
6 SCALA
Performance curves
SCALA2
50/60 Hz
TM1040350
SCALA2 3-45 performance curves
24
SCALA
6
Technical data
SCALA2
Dimensions and weights
H1
H2
H3
B1 L1
TM063305
Dimensions of SCALA2
H1 H2 H3 L1 B1 Weight
Pos. [mm] [mm] [mm] [mm] [mm] [kg]
[inch] [inch] [inch] [inch] [inch] [lb]
302 234 114 403 193 10
SCALA2
11.9 9.2 4.5 15.9 7.6 22
Operating conditions
SCALA2 3-45
45 °C
Max. ambient temperature, 60 Hz models
(113 °F)
55 °C
Max. ambient temperature for 1 x 200-240 V, 50 Hz models
(131 °F)
45 °C
Max. liquid temperature
(113 °F)
Maximum system pressure [bar (psi)] 10 (145)
Max. inlet pressure [bar (psi)] 6 (87)
Max. head [m (ft)] 45 (147)
Nominal head [m (ft)] 27 (88.6)
Nominal flow [m3/h (GPM)] 3 (13.21)
IP Rating X4D (Outdoor installation)
Pumped liquids Clean, fresh water and chlorinated water < 300 ppm
Noise level [db(A)] < 47
Electrical data
50/60 Hz
Voltage and frequency P1 P2 n In
Insulation class
[V] ([Hz]) [W (hp)] [W (hp)] [rpm] [A]
1 x 200-240 (50/60)
550 450
1 x 208-230 (60) 5200 2.80 F
(0.74) (0.60)
1 x 115 (60)
25
6 SCALA
Construction of SCALA2
SCALA2
TM063306
Exploded view of SCALA2
Material specification
Pos. Component Material
Aluminium, Composite and
1 Combined pump and stator housing
EN 1.4301 / AISI 304
2 Control box cover Composite
3 Pump cover Composite
4 Shaft seal Carbon/Ceramic
5 Chamber stack (four stages) Composite
9 Non-return valve, outlet Composite
Composite, Butyl and
10 Pressure tank complete
EN 1.4301 / AISI 304
11 Connection part Composite
19 Drain plug Composite
22 Thread R 1" / NPT 1" Composite
24 Non-return valve, inlet Composite
26
SCALA
6
SCALA2
Safety approvals
PS
ACS
Combined
WATER QUALITY
Drinking water system component
Water circulation pump NSF/ANSI 61
99K4 MH26400
NSF/ANSI 372
Suction performance
H H
[ft] [m]
150 46 SCALA2
44
140
42
130 40
38
120
36
34
110
32
100
30
28
90
26
80 24
22
70
20
60 18
16
50
14
40 12
10
30
8
1m
20 6
3m 2m
4 8m
4m
10 5m
2 6m
7m
TM066277
0 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 4.2 Q [m³/h]
0 2 4 6 8 10 12 14 16 18 Q [US GPM]
27
7 SCALA
Accessories
7. Accessories
SCALA twin accessory set Construction of SCALA twin accessory set
1 2
TM075392
TM075402
3
4
Twin accessory set 5
Product numbers
Valve Manifold
Description Part number
Connection Connection
SCALA1 twin accessory set 1" Rp 1 1/4" Rp 99725165
SCALA1 twin accessory set 1" NPT 1 1/4" NPT 99725168
SCALA2 twin accessory set 1" Rp 1 1/4" Rp 99743076
SCALA2 twin accessory set 1" NPT 1 1/4" NPT 99743075
28
SCALA
7
Accessories
The pump may produce a clicking noise if there is positive
Flexible hoses pressure at the inlet of the pump. In this case, you can
mount a locking pin to avoid this noise. When a locking
pin is mounted, the self-priming function is not applicable.
If the pump has a negative pressure at the inlet, removing
the locking pin is necessary to enable the self-priming
function.
The pin is also available as an accessory.
TM080290
Product numbers
Description Product number
Flexible hose set 99891639
Flexible hose set (with brass elbow
99891647
connection)
29
7 SCALA
TM075393
p P
[psi] [bar]
3.0
Inlet filter accessory 0.20
2.5
0.16
2.0
When using SCALA products for pumping rainwater or 0.12
• Clean water provides long life for the pump. 0.0 0.00
TM075373
0 1 2 3 4 5 6 7 8 Q [m³/h]
30
SCALA
8
Product numbers
8. Product numbers
Guide on how to read the product number tables
Abbreviation Description
SNI Warranty card for Indonesia is included.
Printed installation and operating instructions in English (GB) and Arabic are
ARB
included.
CCC CCC approval on the nameplate.
CSA CSA approval on the nameplate.
SCALA1
50 Hz
Pump model Voltage Plug type/cable Country of origin Product number
SCALA1 3-25 1 x 230 V 50 Hz Schuko Hungary 99530403
SCALA1 3-35 1 x 230 V 50 Hz Schuko Hungary 99530404
SCALA1 3-45 1 x 230 V 50 Hz Schuko Hungary 99530405
SCALA1 5-25 1 x 230 V 50 Hz Schuko Hungary 99530406
SCALA1 5-55 1 x 230 V 50 Hz Schuko Hungary 99530407
31
8 SCALA
60 Hz
Pump model Voltage Plug type/cable Country of origin Product number
SCALA1 3-25 ARB 1 x 230 V 60 Hz No plug Hungary 99530438
SCALA1 3-35 ARB 1 x 230 V 60 Hz No plug Hungary 99530439
SCALA1 3-45 ARB 1 x 230 V 60 Hz No plug Hungary 99530440
SCALA1 5-25 ARB 1 x 230 V 60 Hz No plug Hungary 99530441
SCALA1 5-55 ARB 1 x 230 V 60 Hz No plug Hungary 99530441
32
SCALA
8
SCALA2
Product numbers
50/60 Hz
Pump model Voltage Plug type/cable Country of origin Product number
SCALA2 3-45 1 x 230 V 50/60 Hz Schuko Serbia 98562862
SCALA2 3-45 1 x 230 V 50/60 Hz Schuko Serbia 99027073
SCALA2 3-45 SNI 1 x 230 V 50/60 Hz Schuko Serbia 99027077
SCALA2 3-45 CCC 1 x 230 V 50/60 Hz No plug Serbia 98562863
SCALA2 3-45 1 x 230 V 50/60 Hz No plug Serbia 98562865
SCALA2 3-45 1 x 230 V 50/60 Hz No plug Serbia 99027076
SCALA2 3-45 ARB 1 x 230 V 50/60 Hz No plug Serbia 99448121
SCALA2 3-45 1 x 230 V 50/60 Hz Australia Serbia 98562866
SCALA2 3-45 1 x 230 V 50/60 Hz UK Serbia 98562870
SCALA2 3-45 1 x 230 V 50/60 Hz Argentina Serbia 98562872
SCALA2 3-45 1 x 230 V 50/60 Hz Chile Serbia 99342334
SCALA2 3-45 1 x 230 V 50/60 Hz Thailand Serbia 99371163
SCALA2 3-45 1 x 230 V 50/60 Hz India Serbia 99471149
SCALA2 3-45 CSA 1 x 230 V 50/60 Hz US Serbia 98562817
33
9 SCALA
Grundfos Product Center
When you select your country, you will see the menus below. Note that some menus may not be available depending on
the country.
Example: https://product-selection.grundfos.com/uk
Pos. Description
1 Products & services enables you to find products and documents by typing a product number or name into the search field.
2 Applications enables you to choose an application to see how Grundfos can help you design and optimise your system.
3 Products A-Z enables you to look through a list of all the Grundfos products.
4 Categories enables you to look for a product category.
5 Liquids enables you to find pumps designed for aggressive, flammable or other special liquids.
6 Product replacement enables you to find a suitable replacement.
7 WWW enables you to select the country, which changes the language, the available product range and the structure of the website.
8 Sizing enables you to size a product based on your application and operating conditions.
34
99735562
ECM: 1366409
www.grundfos.com
Tel: +45 87 50 14 00
DK-8850 Bjerringbro