SUYANG

Download as pdf or txt
Download as pdf or txt
You are on page 1of 45

Suyang Electric

Code to learn more

PRODUCT
SELECTION
GUIDE

Suyang Quality, Rock Solid

Dayi Industrial Zone,Yangzhou,Jiangsu,China


Company Introduction
Suyang Electric
Committed to providing safe, reliable products and intelligent solutions
Bring more excellent low-voltage distribution experience to customers Yangzhou Suyang Electric Co.,Ltd was founded in 2006, is a high-tech
enterprise which specialized in low voltage apparaus, the main products of the
company include automatic transfer switch, load-disconnector switch,
disconnecting fuse group, control and protection switch and low voltage electrical
equipment.

Suyang Products are widely used in various fields like electric power, ship
transport, high-rise building and residential. The products meet our customer's
need from design, development, performance to moulding and so on because
we always take user requirements as guidance. Suyang has passed the
ISO9001 quality management system certification, TUV certification and
accreditation mandatory CCC, and all of our products meet CE and ROHS
standards.

Suyang insists on quality makes brand, it has been successively appraised


as “National User Satisfaction Product” and “Outstanding Quality Product”.
We will continue to upload our brand concept: “Suyang Quality, Rock Solid”,
and make greater efforts to provide cost effective products and a full range of
service for our customers. In order to build the pioneer brand of low-voltage
electric fild, we will meke unremitting endeavor!
Suyang Quality, Rock Solid

The company covers an area of 18000 ㎡ , with a total construction


area of 11000 ㎡ . Suyang has strong technical force, excellent
detection equipment, transforming traditional mode with advanced
Integrity
ADVANCED
equipment, to make manufacturing process automative. To ensure
product stability, the main components are fully designed and Strict
manufactured independently. All products have CCC certification.

EQUIPMENT We are focusing on user practice and product development, and


successfully serve thousands of enterprises.
Pragmatic
Innovative
Suyang Quality, Rock Solid

CONTENTS
E High Breaking Miniature Circuit Breaker 45-51

SYDZ47-63 High Breaking Miniature Circuit Breaker 45

SYDZ47-125 High Breaking Miniature Circuit Breaker 47

A Automatic Transfer Switch 01-19 SYDZ47LE series Leakage Circuit Breaker 48

SYDZ47LE-125 Series 50
SYK1/K2 Series Automatic Transfer Switch 01

SYKZ-F Automatic Transfer Switch Intelligent Controller 07

SYD1 Series Electromagnetic Automatic Transfer Switch

SYQ1 Series Automatic Transfer Switch


10

14
F Moulded Case Circuit Breaker 52-64

SYS1 Series Manual Transfer Switch 17 SYCM1 Series Moulded Case Circuit Breaker 52

SYCM1L Series Leakage Moulded Case Circuit Breaker 55

SYCM1E Series Electronic Moulded Case Circuit Breaker 59

B Load Isolating Switch 20-25

SYF1-20A~3200A Load Isolating Switch 20

G Intelligent Air Circuit Breaker 65-75

SYDW45 Series Intelligent Air Circuit Breaker

C
65
Switch-Disconnector-Fuse 26-32

SYR1 Series Switch-Disconnector-Fuse

H
26
Auto over/under Voltage Protector 76-78
SYR1-63A~1250A Switch-Disconnector-Fuse 28

Overall and Installation Dimensions of SYR1-63A~400A 29 SYG1 Series Auto over/under Voltage Protector 76

Overall and Installation Dimensions of SYR1-630A 31

Overall and Installation Dimensions of SYR1-1250A 32

I Surge Protection Device 79-82

D SYCPS Control and Protection Switch 33-44


SYL1-B Series Surge Protection Device

SYL1-C Series Surge Protection Device


80

81
SYCPS Control and Protection Switch 33
SYL1-D Series Surge Protection Device 82
Suyang Quality, Rock Solid

SYK1/K2 Series Automatic Transfer Switch


I、Introduction

SYK1/K2 Series
SYK1/K2 Series Automatic transfer switch is suitable for rated voltage 690V, rated frequency 50/60HZ,
rated voltage 440V and below, rated current of 16A-4000A, the main power supply system for power supply,
mainly used between in the two powers in the emergency case of the power supply system , in order to make

Automatic Transfer Switch sure the main load of emergency lighting, emergency elevator, lampblack machine to keep continuous and
reliable work. It would be widely used for providing uninterrupted and normal power supply for high-rise
buildings, hospitals, banks, highways, railways, etc..
Meet the standards:
IEC60947-1/GB/T14048 <The General Provisions on low-voltage switch and control equipment>
IEC60947-3/GB 1404.8.3 <Low-voltage switch and control equipment, low-voltage switches, isolators ,
disconnecting switches and fuse combinations>
IEC60947-6-1/GB14048.11 <automatic transfer switch appliance>

II. Products Characteristics

Good installation performance.


Using the double composite contact, horizontal structure, micro motor pre storage and micro control
technology,which basically realize the zero flying fox (no arc shield)
The reliable mechanical interlocking and electrical interlocks make a higher security.
Zero crossing technique, in case of emergency, which can be forced the ATS stop at the zero position
(simultaneously cut off two power supply).
The obvious functions of on-off position indication, padlock, etc., realize the isolation between the power
supply and the load.
High reliability, over 10000 times of service life.
Good electromagnetic compatibility, strong anti-interference ability, no interference to the outside.
High degree of automation.
With the multiple input / output interfaces, so it is convenient for remote PLC control and automation system.
Do not need to be connected with any control components.
Nice appearance, small size and light weight, and it is controlled by the different logic control board and logic,
to operate the inside built motor and gear box to make sure the position of the ATS.

III.Types and Classification

SY K

Pole
A(Automatic-type)S(Distance-type)E(Generator-type)L(Double Load)
Rate current
Design No.
Automatic transfer switch
Yangzhou Suyang Electric CO., Ltd.

IV.Working condition

Ambient air temperature :-25℃~+55℃


Installation location elevation : less than 2000m
Pollution degree: 3
Use category :AC33iB
Install method: horizontal or vertical

A 01 02 A
Suyang Quality, Rock Solid

SYK1/K2 Series Automatic Transfer Switch SYK1/K2 Series Automatic Transfer Switch
V. Technical Parameters VII. Mounting Dimension
L1
Meet standard : IEC947-6-1/GB 14048. 11 L2
Horizontal hole center Auxiliary horizontal Lengthways hole Auxiliary lengthways Hole diameter
Current (A) distance L1 hole center distance L2 center distance H1 hole center distance H2 (mm)
Rated thermal
current(Ith) 80A 100A 125A 160A 250A 400A 6 3 0 A 8 0 0 A 1000A 1250A 1600A 2000A 2500A 3200A
(mm) (mm) (mm) (mm)
Rated isolation H2 2000-3200 475 150 350 220 13
voltage (Ui) 750V 1000V H1

Rated impulse 800-1600 610 / 220 / 11


withstand voltage(Uimp) 8KV 12KV
400-630 425 / 180 / 9
Rated working
voltage (Ue) AC 4 4 0 V 200-300 335 / 80/110 / 7
Rated 125-160 278 / 80/110 / 7
working AC-33IB 80 100 125 160 250 400 630 800 1000 1250 1600 2000 2500 3200
current(Ie) 20-100 233 / 84 / 7
L1
Rated making
capacity 10Ie Note:
Rated breaking 1.The mounting brackets of the ATS must be fixed on the same flat plane, the installation hole size should be adjust according
capacity 8Ie
to the actual situation, take force to use of the wrong hole size for installation is prohibited , or it will be damaged.
Rated limited
breaking current 100KA 70KA 100KA 100KA 80KA H1 2. Recommend to add the busbars on the 2000A ATS or above, meanwhile use the cable installation will increase the
Rated short-time installation support force , so there must increase effective reinforcement measures.
withstand current 7KA 9KA 13KA 50KA 55KA
3.The mounting dimension above is suitable for field installation of users. If need more detailed dimensional parameters , as
Transfer time ≤0.45S ≤0.45S ≤0.6S ≤1.2S ≤1.4S following table:
Rated control A
supply voltage Standard :AC 220V、Customization:AC110V、AC380V、DC12V、DC24V Specifications A B C D E F G H
C

Net weight 3.4 3.4 5 .2 5 .2 8 .1 1 5 .8 1 6 .0 3 6 .5 3 6 .8 37 44 96 105 108 SYK2-20-100A 245 126 233 84 14 30 6 133
Gross weight 4 .0 4 .0 6 .0 6 .0 9 .6 1 9 .0 1 9 .0 42. 0 4 2 .5 43 50 102 SYK1-20-160A 290 166 278 20 36 9 184
D
SYK1-200-300A 355 187 335 25 50 184
B

G SYK1-400-630A 445 260 425 180 40 65 13 262


F E
SYK1-800-1000A 635 350 610 220 63 120 9 321
VI. Structure Specification
SYK1-1250A 635 350 610 220 63 120 321

SYK1-1600A 635 375 610 220 80 120 13 321

SYK1-2000-3200A 635 422 475 350 80 355 13 505


II road connect the H
standby power Electric control parts

I road connect
the main power
VIII. Typical wire connection mode
201-206 ATS control terminals
SYK Series typical control schematic diagram
101-106 Control power terminals
of in-put and out-put
Note:1,This drawing is only
Standby power Main power
applicable to the standard
ATS using which under the
Safety guard board
301-306 working status terminals situation of the voltage is
POWER POWER
I road closing indicator
AC380V/220V (three phases 2 1

Status indication four wires),and frequency is I road 2 road 0 road closing indicator
Use the hand shank to R S T N U V W N power power
50/60HZ. indicator indicator
switch in manual type LED Indicators
2 4 6 8 2 4 6 8
2road closing indicator
2,When using the intelligent Q2 Q1
Auto/Manual electrical interlock
controller ,please use the
1 3 5 7 1 3 5 7
Mechanical interlock
NO.3 terminal as the
feedback port of the access
Fu2
control,and the NO.4 terminal
The bolts for installing
the safety guard boards as the port of the external Fu1
A2 B2 C2 N2 A1 B1 C1 N1
indicator.
Back 2 road Front I road 102 103 104 105 101 106 302 305 304 303 405 404 403 402
bar out-put bar out-put N F
FU1/FU2 is 2A fuse Upper power power
NO.1 control 201
power terminal
end 202
SB1

The out-put load termina 101-106,201-206,301-306 203


SB2
I road closing button
L-type bonding bars are the terminals of ATS NO.3 position NO.4 expands
204 0 road closing button
Lower feedback signal position feedback 205
SB3
Brackets for fixing end 2road closing button
out-put terminal signal terminal
401-406,501-506 terminals Out-put Load Mechanical part Electrical part 206
Brackets for fixing
are used for 630A ATS A2 B2 C2 N2 NO.2 control
power terminal
[Mark] This diagram is
LOAD
suitable for 2、 3、 4、 5 U V W N

connection modes

A 03 04 A
Suyang Quality, Rock Solid

SYK1/K2 Series Automatic Transfer Switch SYK1/K2 Series Automatic Transfer Switch
SYK Series connection modes

SYK1/SYK2 Automatic-type connection mode Automatic-type+Manual-type(Remote-type) connection modes (two main supply)

Automatic Manual
Main power Standby power Main power Standby power

Note: Note:
Hl1 and HL2 are common power supply and standby power indicating instructions respectively SA is the option button for choosing Automatic-type or Manual-type function
HD1 and HD2 are common power supply and standby power input instructions respectively SB1 is the manual power input button (passive contact) for main power supply
FU1 and FU2 are 2A fuses SB2 is the manual input button for standby power supply (passive contact)
101-106, 201-206 and 301-306 are SYK1 connection terminals SB3 is the force to "O" position button (passive contact) (need self lock)

SYK1/SYK2 Automatic-type + Force to O position type (Both powers are break off) connection mode
Start signal for the generator connection mode
Main power Standby power

The generator interface has been supplied (301-306 terminals with the signal of 'UGE1' ) ,
the wiring diagram is as follows:
301 306

Force to "O" position contact terminal (passive) UGE1

Note: UGE1 passive contact connect generator interface


Hl1 and HL2 are common power supply and standby power indicating instructions respectively
Note: UGE1 is the generator interface inside of the ATS with the voltage 220V and relay 301-306.
HD1 and HD2 are common power supply and standby power input instructions respectively
FU1 and FU2 are 2A fuses
101-106, 201-206 and 301-306 are SYK1 connection terminals

Remote-type connection mode(two Main supply )

Main power Standby power

SB1 SB3 Sb2

Note:
SB1 is the manual power input button (passive contact) for main power supply
SB2 is the manual input button for standby power supply (passive contact)
SB3 is the force to "O" position button (passive contact) (need self lock)

A 05 06 A
Suyang Quality, Rock Solid

SYKZ-F Automatic Transfer Switch Intelligent Controller


I.Introduction

SYKZ-F Automatic Transfer SYKZ-F Automatic transfer switch intelligent controller use the microprocessor as its core, could accurately detect
the two phase three phases voltage. It could make accurate judgement on the abnormal voltage(decompression, over-
voltage, under-voltage , phase loss), then control the ATS after a certain time delay. When there is something wrong with

Switch Intelligent Controller one of the power it could send a signal to start the generator.

II. Products Characteristics


The controller can detect two phase three-phase voltage (both could be two main power supply or two generate
electricity ,also one main power and one generate electricity) to test and control ATS . Its performance characteristics
are as follows;
■ It realizes the computer programming control, which can use computer to manage the ATS change to priority,
generator stopping delay, fixed voltage, etc. When use the computer programming,you must open the front panel of the
controller and then use the SG72 interface module (USB to LINK), program through the PC testing software ( the
operation of the computer software please refer to the SYKZ-F testing software introduction )
■ The power come from the I road, II road,A phase ,N phase.
■ The normal delay time of the I road or II road could be set from 0~60 seconds , and the generator as same .
■ The abnormal delay time of the I road or II road could be set from 0~60 seconds , and the generator as same
■Use the panel button to set the functions of 'I road priority(I road automatic change and recover)','Automatic/Manual','no
priority(automatic change manual recover)','II road priority(II road automatic change and recover)', to make sure the
power supply I road priority,II road priority, no priority and the device maintenance.
■ Two roads of N line design separately
■Design the forced disjunction input port, when the input is valid , it could forced the ATS to disjunction position.
■ The LED lights on the panel could clearly show the working status of ATS.
■ Set the double power supply conversion circuits which is needed by the ATS, and its output LO,NO(5A 250V AC) can
be used directly as the ATS working power supply.
■ The output contact capacity of the generator set power-on relay (GENS START) is 7A 28VDC, and the passive
constant contact port.
■ With strong electromagnetic interference ability, suitable for the use in the complex environment of strong
electromagnetic interference;
■ Modular structural equipment, fire-retardant ABS plastic shell, plug-and-pull terminals, small size, compact structure,
installation and maintenance is very convenient.

III. Technical Parameters

◆ Input power
AC power supply of the controller: Ac230v ± 20%(Hz) (I, II. A, N phase voltage).
Detection voltage: Rated 380V (Hz) Three-phase four-wire, other detection voltage levels, please consult before order.
◆ Power supply anomaly amplitude setting range
Over-pressure threshold: 264V (PC only).
Under-voltage threshold: 172V (set only via PC).
◆ Change-over Time
Closing time: 5 seconds, if the switching signal is detected in the process of effective , then immediately disconnect.
Break time: 3 seconds, if the switch in the process of detection of the signal is invalid, then immediately disconnect.
Normal power delay: (0-60) seconds (adjustable through the Controller panel potentiometer)
Abnormal power supply delay: (0-60) seconds, factory value: 5 Seconds (can be adjusted through the Controller panel
potentiometer)
Generator Set power-on delay: I road anomaly after confirmation, the delay start (0-60) seconds (only through the
controller panel on the potentiometer adjustment).
Generator Set Downtime delay: I road after the normal confirmation, delay start (0-60) seconds (only through the
controller panel on Potentiometer adjustment or PC adjustment).
◆I/ II Road closing State detect (can be programmed through the Controller panel button) factory value: Detect I/II Circuit
closing state input, that is the controller must access the switch state signal.
◆ Power consumption
The power consumption of the voltage circuit at the rated voltage is less than 2VA
◆ Environmental conditions
Temperature: (-30~+70)℃ Humidity (20~95)%
◆ Net Weight: 0. 47kg

A 07 08 A
Suyang Quality, Rock Solid

SYKZ-F Automatic Transfer Switch Intelligent Controller


IV.Panel Operation Instructions

Manual status indication SYD1 Series Electromagnetic


I road power indication
Ⅰ AUTO

II road power indication Automatic Transfer Switch
I road closing indication II road closing indication
30 30

I road normal power II road normal power


20 40 20 40
AUTO
10 50 10 50

supply delay potentiometer 0 60 0 60


supply delay potentiometer
00:00 00:00

I road power supply II road power supply


closure button I o Ⅱ closure button

Yangzhou Suyang Electric Co., Ltd

Automatic status indication Automatic/Manual switch button


Double points button

V. Typical connection mode diagram

Typical connection mode


load
L1 L2 L3 N
I road input power

II road input power

R1
S1
T1
N1

103 102 202 203 205 302 303 305


10A
10A
10A
10A
10A

10A

N1 C1 B1 A1 L O N O C O M I II GND S1 S 2 A2 B2 C2 N2
power supply
ATS working

the public end


Controlling

closing control
I road
closing control
II road

Grounding

closing status
I road
closing status
II road

ATS intelligent controller

VI. Appearance and mounting dimensions

Open hole size


110mm

119mm

130mm
111mm

60mm 6mm
129mm
138mm

A 09 10 A
Suyang Quality, Rock Solid

VII. Appearance Dimensions


SYD1 Series Electromagnetic Automatic Transfer Switch
I.Introduction Type S
Rated working current(A)
SYD1 series electromagnetic automatic transfer switch, is suitable for the rated voltage AC440V, rated current
16A, 25A, 32A, 40A, 63A, 125A, 160A, 200A, 250A, 315A, 400A, with 2 pole, 3 pole and 4 pole .
Meet the standards:
IEC60947-1/GB/T14048 <The General Provisions on low-voltage switch and control equipment>
IEC60947-3/GB 1404.8.3 <Low-voltage switch and control equipment, low-voltage switches, isolators ,
disconnecting switches and fuse combinations>
IEC60947-6-1/GB14048.11 <automatic transfer switch appliance>
<High-rise Civil Building Fire Regulations>、 <Architectural Design Fire Regulations>、 <Applied Lighting
Designing Guide>、<Civil Architecture electrical Designing Regulations>

Note: If required, the handle could be removed, the totally high is 110mm.
II. Overview
This product is a new generation of the use of the instantaneous of the PC level ATS , compared with the
traditional motor-driven modem , it has the advantage of simple structure, fast conversion speed (less than 80ms),
and use the main contact system of the single pole double throw(V) structure.which could not lead to the two power
supply connected at the same time ,even if in the emergency situation.

III.Types and Classification

SY P

Pole
Type(T/N/N2)
Rated current (A)
Design No.
Automatic transfer switch
Yangzhou Suyang Electric CO., Ltd

IV. Range of Application

SYD1 series electromagnetic automatic transfer switch is suitable for rated voltage 690V, rated frequency Type S
50/60HZ, rated voltage 440V and below, rated current of 16A-4000A, mainly used between in the two powers in the Rated working current(A)
emergency case of the power supply system , in order to make sure the main load of the important places' could keep
continuous and reliable power supply. It would be widely used for providing uninterrupted and normal power supply for
high-rise buildings, hospitals, markets,banks, fire-fighting, chemical industries,metallurgy, etc..

V.Working Condition

Ambient air temperature :-25℃~+55℃


Atmospheric temperature: The highest temperature +40℃ when the relative temperature is not more than 50%,
the monthly maximum relative humidity 90%, can withstand the influence of moist air at sea.
Pollution degree: 3
Installation Degree: Ⅳ
Installation tilt: ATSE's installation is installed in the cabinet, the installation gradient is not less than +22.5 °
In the AC380V, the distance of the flying arc is 80mm, and the distance of the flying arc at AC660V is 100m,
125A and below of the ATS's installation can not consider the distance.
Use category : AC-33B for 400A and below , AC-31B for 630A and above.

VI. Manual operation methods and Precautions


SYD1 series electromagnetic automatic transfer switch electric operation under the 85%Ue~110%Ue could
guarantee the normal conversion . But for the manual operation due to the strength and speed differences, it can not
be sure. Take the use of the manual operation may lead to the situations of silver contact consumption, welding and
so on. Therefore the manual operation can be performed in the following conditions( note the closing position Flying Arc Distance
instruction):
■Controller has no operation power ■Busbar output without load

A 11 12 A
Suyang Quality, Rock Solid

SYD1 Series Electromagnetic Automatic Transfer Switch

Type S
Rated working current(A)
SYQ1 Series
Automatic Transfer Switch

VIII. Internal Wiring Diagram


■When A power supply, the auxiliary contact point a1, a2 closed, b1, b2 disconnection;
■When B power supply, auxiliary contact point a1, a2 disconnect, b1, b2 closed;
■ a3, a4 for the regular close contact, b3, b4 as often open contact, when the user uses the generator power
supply mode, could control the generators to start or stop according to the generator start-up mode, the maximum
capacity is 220V,5A. Users can also control other devices as needed.

A=A-Power AUX= Auxiliary contacts


B=B-Power Xa,Xb=Control switch
C=Load

A 13 14 A
Suyang Quality, Rock Solid

SYQ1 Series Automatic Transfer Switch SYQ1 Series Automatic Transfer Switch
I.Introduction
VI. Outline and Installation Dimension
SYQ1 Series Automatic Transfer Switch (ATS) is suitable for double power supply system (AC 50/60Hz, rated
voltage is 440V, rated current is 6A-1250A). The ATS can autotransfer between common power supply and standby
power supply to ensure the continuity and reliablity of power supply without manual operation.
W
The body of ATS consists of forward and reversing motor, circuit breaker, mechanical interlock and controller.
W1
The product are used in some important places where not allow blackout: Ⅰ power systems, high-rise buildings,
housing estates, military installations, hospitals, airports, communications, fires, etc. The ATS meet IEC60947-6-1、
GB/T14048.11 standards.
SYQ1 Series Automatic Transfer Switch

Main power Standby power


AUTO Manual

II. Overview

L1
L
SYQ1 Series Automatic Transfer Switch (ATS) is suitable for a three-phase four-wire double power supply
system (AC 50/60Hz, rated voltage is 440V, rated current is 6A-1250A), it can connect one or several load circuits common
closing
standby
closing

from one power supply to another automatically, to ensure the nomal power supply of the load circuit. This Product
are used in industrial sites、 commercial spaces、 high-rise buildings、 residential buildings and other important
places. The ATS meet IEC60947-6-1、GB/T14048.11 standards.
SYQ1-63 (basic type) terminal wiring principle SYQ1-63 (fire、power type) terminal wiring principle
III.Types and Classification Indicator Light is 220V
Terminal:
Indicator Light is 220V
Terminal:
1:Common Power Indicated Output 1:Common Closing Indicated Output
No External Power Supply 2:Common Closing Indicated Output No External Power Supply 2:Standby Closing Indicated Output

Point of Fire Power


Common Signaling

Signal Output
Generator
3:Common Zero Line Output 3:Zero Line Output

(DC24V) Signal Input


Fire Double Portion
SY

Power
Common

Closing
Common

Power
Standby

Closing
Standby

Closing
Common

Closing
Standby
4:Standby Power Indicated Output 4:Common Signaling Point of Fire Power
5:Standby Closing Indicated Output 5:Fire Double Portion (DC24V) Signal Input
Pole 6:Standby Zero Line Output 6:Generator Signal Output
Plug common zero line into terminal 3 Notes: If it is a three-pole ATS, please
Rated Current for Circuit Breaker 1 2 3 4 5 6 Plug standby zero line into terminal 6 1 2 3 4 5 6 plug standby zero line into terminal 3

Design No.
CB-level ATS
Dimension
Yangzhou Suyang Electric CO., Ltd Specification W W1 L L1 H
SYQ1-63/2P 150 135 132 120 122
SYQ1-63/3P 185 165 132 120 122
IV. Service Conditions
SYQ1-63/4P 220 200 132 120 122
◆Ambient Air Temperature ◇Maximum Temperature: +40℃
◇Minimum Temperature: -5℃ W H
◇Average Temperature in 24h: ≤+35℃ W1 Note: If the ATS is two-pole,
please connect zero line with 1
◆Altitude: Installation altitude ≤2000m
1 2 3 4 5 6
◆Atmospheric Conditions: when the maximum temperature is +40℃, the relative humidity is less
than 50%, a high relative humidity is allowed when the temperature is low, for example, when the Normal Standby
Source SYQ1 Series Automatic Transfer Switch Source
temperature is 20℃ , the humidity is 90%. Users should take special measures for condensation

common zero line

COM

fire control input

power output
instruction
normally on
caused by temperature changes.

L1
L
◆Pollution Level: 3
◆Electrical Level: CB
Load Side Load Side

V.Main Technical Parameters (AC220V) (without this feature, null)


SYQ1-100~250

Rated Current Rated Working Working Voltage


Dimension
W W1 L L1 H 1 2 3 4 5 6 7
Product Circuit Instantaneous of Circuit Specification
Poles Voltage of of Control Loop
Model Breaker Releaser Form Breaker(A) Circuit Breaker SYQ1-100/3P 336 317 174 146.5 112
SYQ1-100/4P 366.5 347.5 174 146.5 112
C-type Lighting Protection

instruction
normally on

instruction
standby on

COM

fire control input

power output
3P (general lighting) SYQ1-225/3P 376.5 356 189 162 132
SYQ1 Tripping Current Range: SYQ1-225/4P
5In-10In 411.5 391 189 162 132
SYQ1-400/3P 460 420 350 302 220
4P D-type Power Protection: Note: If the ATS is three-pole, please connect
10In-14In SYQ1-400/4P 510 470 350 330 220 common zero line with 1, standby zero line with 3
SYQ1-630/3P 530 490 350 330 245 SYQ1-400~630
Notes: The input voltage is 230V, only connect to A phase (detection phase) of miniature circuit breaker (MCB).
SYQ1-630/4P 590 550 350 330 245

A 15 16 A
Suyang Quality, Rock Solid

SYS1 Series Manual Transfer Switch


I.Introduction

SYS1 Series SYS1 Series Manual transfer switch is suitable for AC:50HZ,rated voltage 660V below,DC: rated voltage
440V, used in the industrial power supply system for the two low-voltage circuit switching or two of load equipment
conversion or isolation.

Manual Transfer Switch Meet the standards:


IEC60947-1/GB/T14048 <The General Provisions on low-voltage switch and control equipment>
IEC60947-3/GB 1404.8.3 <Low-voltage switch and control equipment, low-voltage switches, isolators ,
disconnecting switches and fuse combinations>
IEC60947-6-1/GB14048.11 <automatic transfer switch appliance>

II. Working condition

The switch can work reliably under the following conditions:


. a, elevation should be below 2000m;
. b, ambient temperature : + 40℃~ -5℃
. c, the relative temperature of air is not more than 95%;
. d, medium without explosive hazard, and the medium of gas and dust that are not sufficient to corrode metal
and destroy insulation
. e, places without significant shaking and shock
. f. Environment without rain and snow
Note: If used in ambient temperature -5℃~+45℃, consult before order.

III. Structure and Characteristics

The switch has a glass fiber reinforced unsaturated polyester resin shell, Spring Energy storage acceleration
mechanism, fast realization connecting and breaking, parallel double breakpoint two separate contact head, use
the chip spring to ensure the contact pressure, automatically determine the limit position of the on-off, has obvious
on-off mark indicating the location of the broken.

IV.Technical Parameters

Meet the standard: IEC60947-6-1/GB14048.11

Conventional
thermal current

Rated isolation
voltage (Ui)
Rated impulse
withstand voltage
(Uimp)

Rated working
voltage (Ue)

Rated working
current(Ie)
Rated making
capacity

Rated breaking
capacity

Rated limited
breaking current

Rated short-time
withstand current

A 17 18 A
Suyang Quality, Rock Solid

SYS1 Series Manual Transfer Switch


V.Appearance and Mounting Dimensions

SYF1 Series
Load Isolating Switch

Mounting
Appearance dimension Wiring dimension Handle
dimensions
Specification

A 19 20 B
Suyang Quality, Rock Solid

SYF1-20A~3200A Load Isolating Switch SYF1-125A~3200A Load Isolating Switch


I.Introduction IV.Appearance and Mounting Dimensions
The SYF1 Series Load isolating switch is suitable for AC 50Hz, rated voltage to 660V, DC voltage to 440V, the
conventional thermal current to 3200A industrial enterprise distribution equipment, used for infrequent access and
separate power off roads and electrical isolation. It could be widely used in construction, power, petrochemical and
other industries, distribution systems and automation systems.
The SYF1-C side-operation Load isolating switch adds a side operation mechanism on the basis of SYF load
isolating switch, which is suitable for the side operation connection and separates the power circuit and the
electrical isolation.
The SYF1-Z conversion load isolating switch is composed of two sets of SYF load isolating Below 630A outside-cabinet
handle mounting dimension
switch(installation:up-down type / left-right type), which is suitable for switching of dual power supply or for
conversion of two load equipment and safety isolation.
Meet the standard IEC 60947-3、GB 14048.3.
With nice appearance, novel and concise, small size, full-featured, it could be the best choice of the field.

SYF1-125~630A
II.Types and Classification Inside-cabinet operation

Installing specialized
SYF1 baseboard

Cabinet-after operation,
marked only needed
Load Isolation switch code
Board-after wiring , the front do not note Below 630A Installing
C side-operation specialized baseboard
Load isolating switch
Auxiliary contact code(refer to diagram), Baseboard dimension
Z conversion load Specification
marked only
isolating switch(up-down)
Z2 conversion load SYF1
isolating switch(left-right) Directly observe auxiliary contact window , SYF1-125~630A/JK SYF1
marked only needed. Outside-cabinet operation SYF1
Diagram
Outside-cabinet operation ,
the inside do not mark
One often-open
one often-closed Appearance and mounting dimensions
Pole: 3 pole,4pole Specification
Two often-open (3 Poles + can break the neutral pole)
two often-closed
SYF1
Example: Rated current 630A, neutral Rated current
pole, outside-cabinet operation, the SYF1
type will be HGLZ-630/4J.
SYF1

III. Structural characteristics SYF1

SYF1
Using modular design, suitable for connecting with the split power circuit or electrical isolation. The 1000A and
above is only could be used for electrical isolation; SYF1
The use of spring energy storage, instantaneous release of the acceleration of the closing mechanism with the SYF1
simultaneous and disconnected parallel double breakpoint contact structure,which has greatly improving the product's
SYF1
electrical performance and mechanical properties;
The use of glass fiber reinforced unsaturated polyester mold plastic and manual handle, to realize high dielectric SYF1
properties, protection and reliable operating safety;
SYF1
With 3 poles, 4 poles (3 Poles + can break the neutral pole);
The front is provided with a marking window ,indicating the On-off state of the contact, which can provide a rear SYF1
observation window to directly observe the On-off state of the contact ,to ensure the reliability and safety of the switch SYF1
operation;
SYF1
Handle can be directly installed on the switch operation ( the cabinet operation), but also through the addition of
long shaft in the power distribution cabinet door operation (the operation outside the counter), to provide convenient SYF1
operation;
SYF1
If needed ,we Can provide often open and closed auxiliary contacts , install special floor panel and front panel
connection modes , to meet the diverse needs of the customers; SYF1
In the breaking position "0", can be used two or three locks to lock the handle to prevent misoperation.

B 21 22 B
Suyang Quality, Rock Solid

SYF1-1000A~3200A Load Isolating Switch SYF1C-125A~630A side-operation Load Isolating Switch

Inside-cabinet
operation Outside-cabinet
operation

Below 630A outside-cabinet


handle mounting dimension

SYF1C-125~630A/K
Inside-cabinet operation

SYF1 Installing specialized


baseboard

Installing specialized
baseboard

Below 630A Installing


Above 1000A specialized baseboard
Installing specialized baseboard Baseboard dimension
SYF1C-125~630A/JK Specification
Above 1000A outside-cabinet Outside-cabinet operation
handle mounting dimension
SYF1 SYF1
SYF1
SYF1

Appearance and mounting dimensions


Specification
Specification

SYF1 SYF1

SYF1 SYF1

SYF1 SYF1

SYF1 SYF1

SYF1 SYF1

SYF1 SYF1

SYF1

SYF1
Specification
SYF1
SYF1
SYF1
SYF1
SYF1
SYF1 SYF1

SYF1 SYF1

SYF1 SYF1

SYF1
SYF1
SYF1

B 23 24 B
Suyang Quality, Rock Solid

SYF1C-1000A~3200A side-operation Load isolating switch


Inside-cabinet handle

SYR1 Series
Outside-cabinet handle
Switch-Disconnector-Fuse

Above 1000A outside-cabinet


handle mounting dimension

SYF1C-1000、1250、1600A

Above 1000A
SYF1C-2000、2500、3200A Installing specialized baseboard

Specification

SYF1
SYF1
SYF1
SYF1
SYF1
SYF1

Specification

SYF1
SYF1
SYF1
SYF1
SYF1
SYF1

B 25 26 C
Suyang Quality, Rock Solid

SYR1 Series Switch-Disconnector-Fuse SYR1-63A~1250A Switch-Disconnector-Fuse


I.Introduction
SYR1 is a modular design structure.
SYR1 Series Switch-disconnector-fuse is a multipolar manually operated switch, the shell is made of glass fiber Ensure connection and disconnection with load, reliable overcurrent and short circuit safety disconnection
reinforced unsaturated polyester, it has high dielectric properties, protection capability and reliable operation safety. protection. Disconnected state is visibly. There are 2p, 3p, 4p (3p + on-off neutral pole). According to fuse, it is
Operation Mechanism is a spring-loaded accumulator, acceleration mechanism for instantaneous release, the divided into a total of 23 specifications (63~1250A).
multi break contact structure is instantaneously connected and disconnected, which is independent of the speed of
the operation handle, and greatly improves the electrical performance and mechanical performance.
The switch-disconnector-fuse ensures connecting and disconnecting circuit on load, and it has reliable III.Structure characteristics
overcurrent or short circuit safety break protection.
Visibly disconnected Front operation: the handle is mounted on the front of the switch;
The switch has a novel and unique shape, with small size and full function, it is the best choice of similar product. Side operation: the handle is mounted on the right side of the switch (which requires separate instructions on
Products meet the national standard GB/T. 14048.3: 《 Low-voltage switchgear and control equipment, low the left);
voltage switch, isolator, isolating switch and fuse combination appliances 》. Front operation outside of the cabinet: the handle is mounted on the front outside distribution cabinet;
Side operation outside side of the cabinet: the handle is mounted on the right outside distribution cabinet
II.Types and Classification (which requires separate description on the left).

SY R1 A / - C J B

ⅠModular(160~400A-1250A)
Style
ⅡMonolithic(400~630A)

rear connection, front connection are not marked Note: Unnecessary functions are
Auxiliary contact not marked.
Operate outside the cabinet, standard extension shaft 330mm F- normally open or normally
The special length is indicated after J, the operation inside closed auxiliary contacts,
the cabinet is not marked.
S- normally open + normally
Side operation, front operation are not marked.
closed S type auxiliary contacts,
Rated current of fuse (A) U-U auxiliary contacts.
Pole number 2p, 3p, 4p
(3p + on-off neutral pole) Selection example: rated current 1 normally open or normally
160A, 3 poles, Side-inside closed auxiliary contacts
Rated current
cabinet operation.
Code
2 normally open or normally
Yangzhou Suyang Electric Co,. Ltd. closed auxiliary contacts

Electrical performance and mechanical performance of SYR1-32A~1250A


Conventional thermal current Ith (A) 32 63 160 250 400 630 1250

Fuse size 00C 00/0 1 2 3 4

Fuse function 600V, AC (V) (W) 7.5 7.5 9.6 18.3 26 40.3 90

Rated insulator voltage Ui (V) (Installation type IV) 690 690 690 690 690 690

Dielectric strength (V)


Rated impulse withstand voltage Uimp (kV) (Installation type IV) 8 8 8 8 8 12 12
The long axis is used to
Rated operating current Ie (A)
Fuse shield operate outside the cabinet
AC22 Cosφ=0.65 32 63 160 250 400 630 1250
380V
AC23 Cosφ=0.35 32 63 160 250 400 630 100

Motor power (kW) 15 30 80 132 220 355 560

Rated limited short-circuit current 100 100 100 100 100 100 100

Rated connection capacity 320 630 1600 2500 400 6300 12500

Rated breaking capacity 256 504 1280 2000 3200 5000 10000
Combination neutral wire connection
Mechanical life(Cycle operation times) 1700 1700 1400 800 800 800 500

Electrical life(Cycle operation times) 300 300 200 200 200 200 100
Operating torque, front operation 15 10 12 15 42 42
3P 1 1.8 3.2 4.8 16 28
Weight (Kg)
4P 1.3 2.3 4.5 6.1 19 33

C 27 28 C
Suyang Quality, Rock Solid

Overall and Installation Dimensions of SYR1-63A~400A Overall and Installation Dimensions of SYR1-63A~400A
A

E 1 or 2 pre open normally


P M
open and normally closed P M 21 16
P auxiliary contact Y
L T L 35
Y 70 D

H1
T

H1
I

U
B

K
B
U
B

K
7 0°

126
SYR1C-63A-3 SYR1-250A-3

I
φ31 4-φ4.5

H1
H1
9 0°
φX I
C E

50
R φX
H R P
A J
50
H 门孔
SYR1-63A~250A side operation
SYR1-63A~400A front operation outside cabinet

C A SYR1C-63A-4 SYR1-250A-4
E
Y P M 21
T L I
H1

90° Y
T
F

U
B

φ31 4-φ4.5
K
B

U
B
F
I

50
H1

J φX SYR1-160A-3 SYR1-400A-3 50
R P 门孔

H
P 70
126.5
SYR1-63A~400A front operation
SYR1-63A~400A side operation outside cabinet
Extension without linkage

Specifications Fuse size Overall dimensions and installation dimensions Specifications Fuse size Overall dimensions and installation dimensions
SYR1-63~400A A B C E F H U I J K L M P R T φX Y SYR1-63~400A A B D E F H U I J K L M P R T φX Y
SYR1-160A-4
63A/3 00C 152 118 192 117 114 95 159 145 5 64 32 63A/3 00C 133 118 20~30 117 114 116.5 95 159 145 5 36 32
63A/4 00C 184 118 192 117 114 95 159 145 5 64 32 63A/4 00C 164 118 20~30 117 114 116.5 95 159 145 5 36 32
160/3 00 164 162 192 126 118 108 100 141 189 140 5.4 68 36 20 2.5 8.5 19.5 160/3 00 150 162 28~30 126 118 108 100 141 189 140 5.4 38 36 20 2.5 8.5 19.5
160/4 00 200 162 192 126 118 144 100 141 189 140 5.4 68 36 20 2.5 8.5 19.5 160/4 00 186 162 28~30 126 118 144 100 141 189 140 5.4 38 36 20 2.5 8.5 19.5
250/3 1 236 195 201 146 162 180 140 185 251 165 6.2 92 60 32 2.5 11 19.5 250/3 1 253 195 28~30 146 162 180 140 185 251 165 6.2 54 60 32 2.5 11 19.5
250/4 1 296 195 201 146 162 240 140 185 251 165 6.2 115 60 32 2.5 11 19.5 250/4 1 313 195 28~30 146 162 240 140 185 251 165 6.2 81 60 32 2.5 11 19.5
400/3 2 278 205 201 149 170 192 150 200 260 175 7 121 66 50 3 11 20 400/3 2 271 205 28~30 149 170 192 150 200 260 175 7 86 66 50 3 11 20
400/4 2 344 205 201 149 170 258 150 200 260 175 7 121 66 50 3 11 20 400/4 2 337 205 28~30 149 170 250 150 200 260 175 7 89 66 50 3 11 20

C 29 30 C
Suyang Quality, Rock Solid

Overall and Installation Dimensions of SYR1-630A Overall and Installation Dimensions of SYR1-1250A

14.5 11.5

68
13
10.5

20
25
O OFF 40
77

330

min330
90°

68

46
28 68
I ON
120 120 min15
442(3P)
Direct padlock handle 562(4P)

Inside cabinet: 330 Extra plus 260 outside the cabinet fix 362 (3P)
fix 482 (4P)
289
A Y
A1 Terminal shield
J2 J J1 11
79.5 34
H
T
R φ13
S

22
fix 250
300
260
SYR1-1250A-3
B1

90
SYR1-630A-3
K

7
U
B

190

° 7
k

55

355
oc
dl
pa

φL E 59
120 120
C
P P P M N
295

SYR1-630A front operation


1. Direct operating handle 4. Terminal shield
SYR1-1250A-4 2. S auxiliary contactNO+NC 5. 1~8 pre open auxiliary contacts
φ31
3. Rear connection terminal (optional) 6. Connection terminal
4-φ4.5

50 Padlock position
SYR1-630A-4
max.Φ0.31 in/Φ8mm
min.Φ0.19 in/Φ5mm
50
门孔 Φ4.5

Φ30
96

SYR1-630A front operation outside cabinet

50
Specifications Fuse size Overall dimensions and installation dimensions 50
90°
SYR1-400-630A A A1 B B1 C E H2 J J2 J1 K M N P R S T U φL Y 0

630A/3 3 470 345 300 150 348 268 85 250 76 250 38.5 162 80 50 50 7 260 7 74
Padlock position
630A/4 3 550 425 300 150 348 268 85 250 100 76 250 38.5 162 80 50 50 7 260 7 74

C 31 32 C
Suyang Quality, Rock Solid

SYCPS Control and Protection Switch


I. Product description
The control and protection switch is a new type of product in low voltage electrical apparatus. It is the first

SYCPS generation of major products to fill the gap in our country in 90s.
Standards:“ Low voltage switch equipment and control equipment sixth parts: multi-function electric appliance

Control and Protection Switch second section: control and protect switch electric appliance”“Low voltage switch equipment and control equipment
multi-function electrical appliance (equipment) second parts: control and protection switch electric appliance
(equipment) “(Equate adoption)

II. Product overview


SYCPS switch is an intelligent multi-function low-voltage switchgear, It uses the electromagnetic system as the
operating mechanism to drive the contact movement to switch on and off the circuit. It detects the main circuit current
through the intelligent control unit, and perform logical calculations and data processing to control the electromagnetic
system movement characteristics, complete fault diagnosis and protection. The SYCPS switch has realized the main
functions of circuit breakers, contactors, thermal relays and other electrical appliances on a single device, and has
been ranked as an international leader in integration.
Standards:GB14048.9 IEC 60947-6-2

Electrical symbols

III. Application
SYCPS products using single a product structure modularization, it is the integration of traditional circuit breaker
(fuse), contactor, overload (or over-current, phase failure) protection relays, starter, isolator and other main functions,
it has remote automatic control and local direct manual control function, with panel indicator and electrical signal alarm
function, with overvoltage and undervoltage protection function, with phase failure protection function, with the
characteristics of time-current protection coordination (anti time limit, time limit and instantaneous three phase
protection characteristics). Matching function modules or accessories according to the requirements , to control and
protect load and distribution loadall of all kinds of motor.
SYCPS is mainly used in power system which is AC 50Hz (60Hz), rated voltage to 690V, rated current from 1A
to 125A, and it can connect, load and break the current under normal conditions (including prescribed overload
conditions), and it can be switched on, carrying and breaking the current under prescribed abnormal conditions (such
as short circuit).

IV. Application fields

Low voltage distribution system, motor control and protection system for general industry, agriculture, commerce,
civil construction, such as: single machine control and protection in factory or workshop (equivalent to power terminal);
motor control center (MCC), especially the intelligent electric control system or MCC with high breaking capacity (the
distribution control and protection system requiring Icu50kA or cs35kA); integrated distribution system; Electrical
control and protection systems for lighting, power conversion, fans, air conditioning, fire fighting, water supply, etc. Of
modern buildings.

V. Operating conditions
Elevation:≤2000m Installation category: III II
Ambient temperature:-25℃~+40℃ Fluctuation range of control power supply voltage: 85%us-110%us
(you must take special project at -40℃~+80℃) Pollution degree:3
Relative humidity of air:90%

D 33 34 D
Suyang Quality, Rock Solid

SYCPS Control and Protection Switch SYCPS Control and Protection Switch
VI. Product features VIII.Types and Classification
Compared with the low voltage power distribution and control system composed of discrete components
SY CPS
★Easy to design and install, , simple operation, convenient application: SYCPS switch integrates circuit breakers, contactors,
thermal relays and other control and protection functions on a single structure of the appliance, there is no need to consider the Slection Function Code: F-fire, G-isolation, L-leakage, T-communication
characteristic matching among the components in the user selection. There's no need to reduce capacity under the AC44 usage
category, you can choose the correct SYCPS switch products only based on either the load power or the rated operating current. Control supply voltage:M-AC220V、Q-AC380V
SYCPS switch can replace the low-voltage distribution and control system of a variety of electrical appliances, reducing the workload
of the design and installation personnel. Accessory code: 02--2 normal open and 1 normal closed +1 short circuit and
1 overload、06-3 normal open and 2 normal closed + 1 short circuit and 1 overload
★Small size, high reliability and easy maintenance: SYCPS switch has changed traditional configuration of multiple component
series combination, make the installation space reduced more than 50%, the system reliability is greatly improved; After breaking the
fault line, if the fault is eliminated, the SYCPS switch can be safely put into continuous operation without maintenance, and the Intelligent release code (Express by class code + rated current)
maintenance is simple.
★Complete function, complete protection: SYCPS switch circuit, blocking the road, overload, phase, phase imbalance, residual Poles: in two digits, the former represents the poles, and the latter indicates
the number of protective poles.
current (leakage), overvoltage, voltage loss, undervoltage protection function can also be ground fault, personal electric shock hazard
Breaking capacity: C-economical type(35KA), Y-standard type(50KA),
provide indirect protection. At the same time, a remote communication function. The user can choose according to need flexible. Ii H-high breaking type(80KA)
can improve the function and reliability of information system.
Compared with molded case circuit breakers Main release current: 6.3~125A
★ High breaking capacity: SYCPS switch has a strong short-circuit breaking capacity (Ics is 50KA, Icu is 80KA), the total
short-circuit breaking time is less than 10ms, the current limiting coefficient is less than 0.4, and the dynamic and thermal impact of Product Combination: Basic type - no code、N-reversible control、
J--voltage reducing starter、S-ATS、D-two speed motors、
the short circuit current on the system can be reduced, and it can achieve zero arc. Z-main and auxiliary motor controller
★ Protection characteristics is perfect, reasonable and reliable: implementation of protection measures, the use of digital
measuring and processing technology action is accurate, reliable, continuous tuning values can be set within a predetermined range. Current level of shell frame(45、125)
Functions: voltage detection (V products), current detection, fault warning, fault type recognition and memory functions.current
detection, fault warning, fault type identification and storage memory. Control and protection switch apparatus (Multi-function electric appliance)
★Long service life, high reliability, remote control: SYCPS switch increase the breaking speed and reduce the breaking time by
pulse degaussing technology, and abandon the traditional mechanical tripping device in circuit breaker. Fewer parts, high reliability, Yangzhou Suyang Electric Co., Ltd.
and can realize remote control.
Compared with contactor
SYCPS switch operation electromagnet adopts intelligent control, the coil is powered by a DC pulse, the intelligent controller
can adaptively adjust the width of the pulse exciting voltage according to the supply voltage, to ensure the optimum matching between IX.Working principle
suction characteristics and reaction characteristicsso, which greatly reduces the collision and contact bounce closure process,
contact wear is small, not welding, long life, in the use of AC43 category can reach more than 1 million times. The SYCPS switch consists of two parts, the main body and the intelligent controller, the main method of electromagnetic
system is operating mechanism, driving the contacts movement to achieve on the main circuit or breaking. Using the intelligent
★Connect, breaking capacity: SYCPS switch can be switched on, carrying, breaking current 16le, it is suitable for work in the
control and power electronic technology to control the motion of electromagnet characteristics; Using pulse demagnetization
heavy load situation, in the use of AC44 class without derating. Especially A type products of SYCPS, is suitable for heavy-duty lifting
technology to improve the speed of opening of electromagnet.
device and frequent operation.
The intelligent controller detects the main circuit current and the coil supply voltageI, according to the main circuit current fault
★Low energy consumption, no noise: when the electromagnet is pulled in, it uses the DC low voltage power supply to keep the
diagnosis, calculate the winding temperature rise, once the fault occurs, then issue tripping instructions to control the electromagnet
electromagnet attracting, without noise and low energy consumption.
breaking. In normal working conditions, the display shows the current value of each phase and the temperature rise of the winding in
★ Non burning coil: when the coil control voltage fluctuations and coil heating, SYCPS switch automatically according to the
turn, to facilitate the user to keep abreast of the operation of the switch. If the user open the alarm function, when the protective circuit
control voltage and coil resistance adjusting pulse width of excitation voltage, electromagnet, changed into DC low voltage power
or equipment overload temperature rise to the limit of action, the switch issued warning sound, prompting operators to take
supply. Low coil power consumption, even if the long-term work, the coil heat is low, do not burn the coil.
appropriate measures to prevent the motor continues to overload. If the overload is not eliminated in time, the switch will break the
fault line when the temperature rise reaches the limit. If the warning function switch is not opened, when the fault reaches the safety
VII.Product function of the equipment, the SYCPS switch will trip and make a sound alarm.

★ Circuit breaker function: short circuit protection function, it can be divided into short-circuit current breaking the Body panel diagram
corresponding level specified in 10ms, the limiting factor is less than 0.4. If the rated service short-circuit breaking capacity Ics of Automatic control position: CPS coil control contact in
SYKB0-100 switch is 35KA, rated ultimate short-circuit breaking capacity Icu is 50KA. At the same time, V products has fuctions with Tripping position: In the connected circuit, such as overload, the closed position, in this state, through the coil
overvoltage, undervoltage, loss pressure protection. overcurrent, short circuit, open phase, and remote shunt tripping, control circuit on-off can be remote automatic control.
the product corresponding function module take action, to make the
★Contactor function: 50Hz or 60Hz AC, rated insulation voltage is 660V. Under AC43 and AC44 categories, rated voltage is main contacts and coil control contacts are in the open position.
380V, rated current is 1A~100A, frequent operation, motor starting control, stop or reverse, and can realize remote control.
★Thermal relay and overcurrent relay function: with perfect, reasonable, continuous three section protection function and motor
starting time limit protection, overload protection mode uses the most advanced double time constant index, and the protected object
allows the overload characteristic matching, its action is accurate and reliable. Disconnect position: coil control contact is in the
disconnection position, and the CPS main contact
★ Starter function: can replace contactor and thermal relay combination starter, control motor start. Phase missing, three- remains in the disconnected position.
phase unbalanced protection function (NQ, WQ products) leakage protection function (L products).
★Counter function: During operation, the cumulative operation times of the switch are recorded and displayed on the display,
users can decide whether or not to replace the new switch according to the recorded data, calculate shift output or the remaining life Re-trip position: When the operation knob is
of the switch. rotated to the position, the tripping CPS can be
normally reset and re-trip.
★Detection and display function: alarm function can be turned on or off according to the user's needs, when the equipment is
overloaded and the temperature rise reaches the warning limit, warning voice, to facilitate timely troubleshooting.
★ Fault diagnosis function: during operation, the current value of three-phase winding is detected in real time, and the
temperature rise of three-phase winding is calculated, the detection and processing results are shown on the display in turn.
★Warning function: when the system fails, the switch can automatically identify, store and record the fault type and display it,
which is easy for users to troubleshoot.

D 35 36 D
Suyang Quality, Rock Solid

SYCPS Control and Protection Switch SYCPS Control and Protection Switch
XI. Parameters of intelligent release
Main circuit contactor (including contact system, short circuit release)
The main circuit contactor of SYCPS control and protection switch consists of moving and static bridge type double break contact, Rated current Rated operating current of Rated operating current Control power
Shell current of main body overload electronic release adjustment range of range of 380V Usage Rated Rated
grid plate arc extinguishing chamber and current limiting fast short-circuit release mechanism. Each pole is independent of each other. overload electronic release class voltage(V) power(Hz)
(Ith A) (Im A) (Ie A) (kW)
The main circuit contactor with limited flow type quick short-circuit tripping device, and extinguishing system of high breaking capacity, (Ie A)
high current limiting characteristics (limiting coefficient is less than 0.2) of the backup protection, tripping setting current value is:
16In+20%, the numerical value is not adjustable, and is only related to shell grade. When the load is short circuited, the release opens the
main contactor quickly(2~3ms), at the same time, it drives the operating mechanism to cut off the control coil circuit, then all the main
circuit is disconnected.

X. Parameters and protection characteristics

SYCPS Technical parameter

Frame
CPS-45 CPS-125
Project

、125

Rated operating current (IeA) 25-125


125
Rated operating voltage (UcV)
125 125 80 125 40 55
AC-43 Electrical life (Million times)
Control supply voltage Auxiliary contact technical data
Mechanical life Usage class Capacity

Average power dissipation Starting capacity


of control circuit (VA)
Retention capacity
(VA)

Pull in time Alarm contact technical data


Movement time b)ms Rated voltage (Ui V)
Usage class
Prescribed heating current (Lth A)
Release time Turn off/on power (V)
c)ms Breaking capacity (VA)
Rated operating short-circuit Operating Rated operating current (A)
breaking capacity (IcskA) voltage
Capacity(VA)
Rated current level of release Rated
Rated operating current (A)
(IeA) voltage

Short-circuit breaking time


XII.Protection characteristics

SYCPS switch has the characteristics of overload, reverse time, long time delay, short circuit transient, short
circuit and short delay, three phase protection, and motor starting timing limit. And functions of residual current,
delay type protection, phase or three-phase unbalanced protection, overvoltage protection, undervoltage
protection and reclosing.

D 37 38 D
Suyang Quality, Rock Solid

SYCPS Control and Protection Switch SYCPS Control and Protection Switch
XIII、Installation and appearance
Protection characteristic parameter

Overload protection See protective characteristic data

Movement time(min)
Phase failure or three-phase
unbalance protection Current setting range (multiple)

Action time(S)
Short circuit short time
delay protection
Voltage setting range (multiple)

Action time(S) Continuously


Overvoltage protection adjustable
Voltage setting range (multiple)

Action time(S)
Undervoltage protection
Voltage setting range (multiple)

Rated leakage current (type AC)

Residual current protection Reclosing time(S)


See residual current protection action
Action time(S)
characteristics

Protection characteristic data


Protection characteristic data A multiple of the setting current value Operation time of breaking circuit

Appearance and installation size of 45 frame, 3p SYCPS-12,16,20,32,45


Overload inverse time limit Inverse time can be adopted TH35 type standard rail installation

Short circuit short delays Definite time

Short-circuit transient Inverse time

Motor starting Definite time

Operation characteristic of residual current protection

Protection Limit
features non-actuating Residual current
(optional) time
Maximum movement time
Limit non-actuating time
Maximum movement time
Limit non-actuating time
Maximum movement time
Limit non-actuating time

Maximum movement time


Limit non-actuating time
Maximum movement time
Limit non-actuating time
Maximum movement time
6
Limit non-actuating time
Maximum movement time
7
Limit non-actuating time Appearance and installation size of 45 frame, 3p SYCPS-63、80、100、125

D 39 40 D
Suyang Quality, Rock Solid

SYCPS Control and Protection Switch SYCPS Control and Protection Switch
XIV. SYCPS-F fire-type control and protection switch XVI. SYCPS-G isolated control panel

Purpose
SYCPS-Ffire-type control and protection switch (60Hz) is mainly used in fire protection system which is AC 50Hz, Tripping position: In the connected circuit, Automatic control position: CPS coil control
rated voltage to 690V, rated current from 0.16A to 125A. It is capable of being switched on, carrying normal such as overload, overcurrent, short circuit, contact in the closed position, in this state,
open phase, and remote shunt tripping, the through the coil control circuit on-off can be
conditions, including prescribed overload, current under overcurrent conditions, it can realize only alarm, no product corresponding function module take remote automatic control.
action, to make the main contacts and coil
tripping, and can connect, load and break the current (such as short circuit current) under abnormal conditions, control contacts are in the open position.
and realize the alarm and trip, and the main parameters of the main circuit and the accessory module are the same
as the basic type of the SYCPS. Disconnect position: coil control
contact is in the disconnection
Product type position, and the CPS main contact
remains in the disconnected position.
Take SYCPS-F fire control and protection switch circuit as main body, derived the following series of
products: Re-trip position: When the operation
knob is rotated to the position, the Isolation position: turn the CPS
SYCPS-FG Isolated fire fighting type tripping CPS can be normally reset knob to OFF, turn the isolating
and re-trip. latch in the knob (available
SYCPSD-F Fire fighting type double speed motor controller padlock), and the main internal
circuit is in the isolated state of
SYCPSD3-F Fire fighting type three speed motor controller disconnection.
SYCPSJ-F, SYCPSJ2-F, SYCPSZ-F, SYCPSR-F Fire fighting pressure reducing starter
SYCPSN-F Reversible control and protection switch apparatus
SYBK1-F Fire protection control box
Special Note
In the line failure, the fire-type product alarm, you must turn the red knob to the re-trip position, you can lift the
alarm signal, when you continue to use, you should turn the knob to the connecting position. XVII.Basic electrical control diagram

XV.SYCPS-G isolated control and protection switch Secondary Power Local manual Auxiliary signal Alarm signal Secondary Power Local manual Auxiliary signal Alarm signal
power protection control operation stop short circuit fault power protection control operation stop short circuit fault
Purpose
SYCPS-G isolated products is applicable to the power distribution circuit and electric circuit, the main
circuit can meet the isolation requirements, also meet the requirement of isolation of control circuit, the position
of the position indicator (operation knob) can be clearly displayed.
Parameters of the main circuit and the accessory module are the same as those of the SYCPS.
When the handle is in the isolated position, the isolating product has a locking device and can be locked.
The padlock is supplied by the customer.

The meaning of each part of the product model is as follows

SY CPS 45 C 33 B40 06 M F G

With isolation function


Secondary Power Local manual Auxiliary signal Alarm signal Secondary Power Local manual Auxiliary signal Alarm signal
With fire protection function power protection control self-locking operation short circuit fault power protection control self-locking operation short circuit fault

Operating voltage:220V
Accessories code:
06-3 normally open 2 normally closed +1 short circuit 1 overload
40A Digital tube intelligent controller rated operating current
Poles and protection:3p with 3p protection

Breaking capacity:C- economical type


CPS main frame size rated current

Control and protection switch

Yangzhou Suyang Electric., Ltd.

D 41 42 D
Suyang Quality, Rock Solid

SYCPS Control and Protection Switch SYCPS Control and Protection Switch
XVIII. SYCPS-N communication type control and protection switch XIX.SYCPS-L leakage-type control and protection switch

1. Functional overview 1.Functional overview


SYCPS-N control and protection switch with communication function is suitable for remote communication, it
SYCPS-L leakage-type control and protection switch is designed to measure the fault of motor when it's running
provides standard RS485 communication interface, the upper terminal of the interface module is equipped with high-
in the ground through the built-in zero sequence current transformer, and determine whether to start the leakage
speed photoelectric isolation which improves the anti-interference ability. It supports communication with Modbus-
RTU, Protibus-DP and many other protocols, and communication distance up to 1200 meters. At the same time, alarm function by zero sequence current.
various parameters on the system can as many as 255 motors were modified, setting, data transmission, data
recording and displaying dynamic parameters of the motor. 2.Leakage settings

When leakage current is 100mA, SYCPS action time is less than 0.2s. The leakage current value can be set
2. Network communication
according to user's needs according to the setting value serial number, corresponding leakage current value of set
value serial number see below.

Set value serial


1 2 3 4 5 6 7 8
number(L)
Leakage current
50 75 100 150 200 300 400 500
value(mA)

3. Operation instruction
RS485 When SYCPS leakage-type control and protection switch is operating, three-phase current and leakage
1SYCPS 2SYCPS 3SYCPS 4SYCPS 5SYCPS 6SYCPS NSYCPS current are displayed circularly, which is convenient for users to check the leakage of load.

This module is optional, and the fire protection type can be selected.
RS485 communication interface with open field bus, comply with the Modbus agreement. 4. Main parameters and application instructions

Main technical parameters of SYCPS leakage type control and protection switch are the same as those of

3. The software control function of SYCPS system SYCPS standard type

SYCPS system control software see software installation manual


5. Design and illustration
major function:
3.1:Remote setup of SYCPS-N switch parameter
Representation of design:
3.2:Remote management of motors controlled by SYCPS-N
Electrical symbols and product symbols
3.3:Through the real-time monitoring software, the motor show real-time voltage, current situation and typical fault.
3.4:The motor start and stop, and other fault historical data queried by software

4. Design and illustration

SYCPS-L

Representation of design: Design1: Design2:


Electrical symbols and product symbols SYCPS-45N/380/35A means: SYCPS-125FN/380/45KW means:
1.Communication-type control and protection 1.Fire-communication-type
switch with RS485 communication interface control and protection switch

2. Frame current rating is 45A with RS485 communication interface


2.Frame current rating is 125A Design1: Design2:
3.Motor protection
4.3Pwith 3p protection
3.Motor protection SYCPS-45L/20A means: SYCPS-125GL/380/30KW Means:
4.3p with 3p protection
5. Accessories: 3 normally open + 1.Leakage-type control and protection 1.Fire-leakage-type control and protection switch
SYCPS-N 5. Accessories: 2 normally open +
2.Frame current rating is 125A
2 normally closed +2 alarm switch with leakage protection
1 normally closed +2 alarm
6.Operating voltage is 220V (implied) 2.Frame current rating is 45A 3. Motor protection
6.Operating voltage is 380V
7.Intelligent release current setting for 35A 7.Motor control power is 45KW 3.Motor protection 4. 3p with 3p protection
4. 3p with 3p protection (implied) 5.Accessories: 3 normally open +
5.Accessories: 2 normally open + 2 normally closed +2 alarm
1 normally closed +2 alarm 6. Operating voltage is 220V
6.Operating voltage is 220V (implied) 7. Motor control power is 30KW
7. Intelligent release current setting for 20A

D 43 44 D
Suyang Quality, Rock Solid

SYDZ47-63 High Breaking Miniature Circuit Breaker


I.Scope of application II.Type designation

SYDZ47 Series High Breaking


This product is suitable for short circuit protection and overload SY
protection, it is used in distribution system for lighting distribution
Rated current value
systems or motors. It has compact appearance, light weight,
excellent performance, reliable high breaking capacity, rapid
Instantaneous release type

Miniature Circuit Breaker


(expressed in B, C, D)
release, rail installation, shell and components are made of high
impact resistance and flame retardant plastics and long service Poles (expressed in Arabia figures,
neutral is expressed in N)
life, it is mainly used for overload and short circuit protection for
power supply which is AC 50Hz, rated voltage to 400V, rated Frame Size Rated Current
current to 63A, at the same time, electrical equipment and
lighting circuits can be broken down frequently under normal Design code
conditions. Miniature circuit breaker
This product complies with GB 10963.1 standard. Yangzhou Suyang Electric Co., Ltd.

III.Characteristic
1.Breaking capacity (see Table 1) Table 1

Rated current Rated ultimate short-circuit breaking capacity Tripping current range of
Poles Voltage (V)
(A) Breaking current instantaneous release

3In~5In(Type B)
5In~10In(Type C)
10In~20In(Type D)

2.Protective characteristics of over-current tripping device (see Table 2) Table 2


Serial Release Rated current of release
number type I/In Tripping time Starting state ambient temp

No tripping cold state

Tripping thermal state

Tripping cold state

Tripping cold state

No tripping cold state

Tripping

Tripping cold state

3.Current limiting characteristic


DZ47 series miniature circuit breakers have high current limiting capability, thereby limiting the damage performance
caused by short-circuit (see current limiting characteristic diagram)

IV. Appearance installation dimensions

Current limiting characteristic Appearance installation dimensions DIN-Rail mounting


Short-circuit current dimensional drawing
Expected short-circuit current peak

Expected short-circuit energy

Current limiting peak


Current limiting
short-circuit energy time

E 45 46 E
Suyang Quality, Rock Solid

SYDZ47-125 High Breaking Miniature Circuit Breaker


I.Scope of application

SYDZ47-125 is suitable for short circuit protection and overload protection, it is used in distribution system
for lighting distribution systems or motors. It has compact appearance, light weight, excellent performance, reliable
high breaking capacity, rapid release, rail installation, shell and components are made of high impact resistance
SYDZ47LE Series
and flame retardant plastics and long service life, it is mainly used for overload and short circuit protection for
power supply which is AC 50Hz, rated voltage to 230/400V, rated current to 125A, at the same time, electrical Leakage Circuit Breaker
equipment and lighting circuits can be broken down frequently under normal conditions.
This product complies with GB 14048.2 standard.

II.Type designation III.Main technical parameters

SY 1、Rated current of circuit breaker:63A、80A、100A、125A


Rated current value 2、Poles of circuit breaker: 1P, 2P, 3P, 4P
Instantaneous release type 3、The circuit breaker is an embedded installation (mounted on
(expressed in B, C, D)
poles (expressed in Arabia the mounting rail)
figures, neutral is expressed 4、Rated working voltage of circuit breaker
in N)
5、Rated breaking capacity:Icn=10000A,Ics=7500A
Frame Size Rated Current
6、Over current tripping characteristics are shown in Table 1
Design No.
(ambient temperature is 30 ~35 C)
Miniature circuit breaker
Yangzhou Suyang Electric Co., Ltd.

Table 1
Serial Rated current Starting state Test current Regulation time Remarks
number of release Expected results

cold state No tripping

The current rises


next to the a test Tripping steadily to the specified
value within 5semarks

cold state Tripping


The value in
All values cold state No tripping parentheses is D
The value in
All values cold state Tripping parentheses is D

IV. Appearance and installation dimensions

Overall dimensions
Thermal / electromagnetic tripping characteristic

DIN-Rail mounting dimension 1.Thermal


tripping 1.Thermal
tripping

2.Spot
tripping 2.Spot
tripping

C D

E 47 48 E
Suyang Quality, Rock Solid

SYDZ47LE Series Leakage Circuit Breaker SYDZ47LE-125 Series


I.Scope of application I.Scope of application

Leakage circuit breaker is suitable for leakage protection for power supply shich is AC 50Hz, rated voltage is SYDZ47LE-125 residual current circuit breaker is suitable for AC 50Hz, rated voltage of single pole two line,
230V/400V, rated current to 63A. When someone gets an electric shock or the circuit leakage current exceeds the two 230V, 3P, four line, quadrupole 400V, rated current from 63A to 125A in the circuit, when the electric power
specified value, the leakage circuit breaker can automatically cut off the power supply in 0.1s to ensure personal grid or leakage current exceeds the set value, residual current circuit breaker can cut off the power supply fault
safety and prevent the accident caused by the leakage current of the equipment. quickly in a very short period of time to protect the personal safety of the electric equipment, leakage circuit breaker
Leakage circuit breaker with overload and short circuit protection function, it is used to protect the circuit from with overload and short circuit protection function, it is used to protect the circuit from overload and short circuit, but
overload and short circuit, but also in normal circumstances, line is not installed for frequent use. also in normal circumstances, line is not installed for frequent use.
This product complies with GB 16917.1 standard. This product complies with GB 14048.2, IEC 60947-2 standard.

II.Types and Classification


II.Types and Classification III.Normal working conditions and installation conditions
Rated residual action current
Ambient temperature: -5℃ ~ +40℃ , the average value of 24h is not more than 35
Rated current value degrees centigrade;
Instantaneous release type (expressed in B, C, D) Elevation: the elevation of the installation site shall not exceed 2000m;
Frame Size Rated Current
When a neutral line is used, it is indicated by N, Installation class: Ⅲ;
with overvoltage protection, expressed in G Function code (electronic CBR)
Pollution level: 3;
Poles
Design code Installation: use TH35-7.5 steel installation rail installation;
Frame Size Rated Current
Moulded Case Circuit Breaker Installation condition: The external magnetic field of the installation shall not exceed
Special derivation code 5 times of the magnetic field in any direction; residual current circuit breaker shall be
Electronic leakage circuit breaker installed vertically, the inclination of not more than 5 degrees; the handle is upwards
to connect the power supply position; the installation shall have no significant shock
Moulded Case Circuit Breaker
and vibration.

Residual current interrupting time of leakage circuit breaker is shown in table 1: table 1
Maximum (residual current) breaking time IV.Main parameters and technical performance
Category
4.1 Classification: 4.2.8 The breaking time of the residual current (see Table 1);
Indirect contact Any value 4.1.1 Poles:1P+N、2P、3P、3P+N、4P; 4.2.9 Mechanical and electrical life:

Direct grounding Any value 4.1.2 Short-circuit tripping performance:(8~12)In Electrical life:1500 times,cosΦ=0.85~0.9;

4.2 Main technical parameters: Mechanical life:1500 times;

4.2.1Rated voltage:1P+N、2P:230V;3P、3P+N、4P:400V; 4.2.10 Insulation shock resistance performance:Uimp(V):4000;


Over current trip protection characteristics are shown in Table 2 table 2
4.2.2 Rated current In(A):63、80、100、125; 4.2.11 The residual current operated circuit breaker has the
Serial Release Rated current Test current Tripping time Starting state Expected results Ambient Temp
number of release 4.2.3 Frame Size Rated Current Inm(A):125; capacity of carrying capacity when the peak current is 200A,
the impact current and the peak voltage are 4000V, and the
cold state No tripping 4.2.4 Rated residual action current I△n(A):0.03、0.1、0.3;
surge voltage is under the action of surge overvoltage, without
thermal state Tripping 4.2.5 Rated residual non operating current I△n(A):0.5 I△n; causing misoperation
Tripping 4.2.6 Rated short-circuit breaking capacity Icu(A):6000; 4.2.12 Over-current tripping characteristic curve (see Figure).
4.2.7 Rated residual connection and breaking capacity

No tripping I△m(A):2000;
cold state
All values
Table 1

I△n Maximum breaking time and minimum non driving time


Tripping Serial number
mA I△n 2 I△n 5 I△n 10 I△n
General type ≥30 0.1 0.06 0.04 0.04

III.Installation dimension
Overcurrent protection characteristics (see Table 2)
Table 2
Poles Specified time
Width
Starting state Expected Remarks
Test current
In=63A In>63A results

Cold state 1.05In t≤1h t≤2h No tripping


The current rises steadily to a specified
next to the preceding trial 1.30In t<1h t<2h Tripping value within 5s
Current is switched on by a closed
Cold state 8In t≤0.2s No tripping auxiliary switch
Current is switched on by a closed
Cold state 12In t<2s Tripping auxiliary switch

E 49 50 E
Suyang Quality, Rock Solid

SYDZ47LE-125 Series
Structure and working principle V.Other
5.1 Structure and working principle
5.1.1 Structure
The residual current operated circuit breaker consists of a DZ47LE-125
moulded case circuit breaker and a residual current release device. DZ47LE-
SYCM1 Series
Moulded Case Circuit Breaker
125 is mainly composed of insulation shell, operating mechanism, static and
dynamic contact, delay and instantaneous release, arc extinguishing chamber.
The residual current release is mainly composed of zero sequence transformer,
electronic discrimination control circuit, release push rod, test button and so on.
The moulded case circuit breaker is connected with the residual current
release device by a push rod.
5.1.2 Working principle
When the residual current operated circuit breaker handle is pulled to the ON
position, the moving contact is driven by the mechanical mechanism to the
static contact and is in reliable contact with the static contact , the circuit is
connected. When the circuit is overload, the overload current causes the
thermal bimetallic element to bend and push the lever so that the mechanical
locking mechanism is reset, the moving contact rapidly moves away from the
static contact to break circuit. When the circuit is overload, the short circuit
current causes the instantaneous release action, and the iron core push rod
enables the locking mechanical reset to realize the breaking function. When
residual current or electric shock occurs on the circuit, signals produced by the
zero sequence transformer Trigger thyristor turn-on, the residual current
release core is operated, push rod drives the circuit breaker to trip, and the
residual current action breaker cuts off the power supply in a very short time to
realize the residual current protection function.

5.2 Connection
Suitable for (10~50) 2mm wire connections, tightening torque of the terminal shall not be greater than 3.5N.m. Before installation, users should select
appropriate wire to connect the residual current action circuit breaker to the circuit. The cross-sectional area of the recommended leads is shown in
Table 3. Check whether the residual current operated circuit breaker is in conformity with the normal operating conditions.

Rated current In(A) Nominal sectional area of copper conductor (mm²)

5.3 Product features


Suitable for (10~50) 2mm wire connections, tightening torque of the terminal shall not be greater than 3.5N.m. Before installation, users should select appropriate
wire to connect the residual current action circuit breaker to the circuit. The cross-sectional area of the recommended leads is shown in Table 3. Check whether the
residual current operated circuit breaker is in conformity with the normal operating conditions.
5.3.1 Operating mechanism of residual current operated circuit breaker is free tripping mechanism with energy storage, the contact close fast, it overcomes the
adverse effect caused by human operation handle speed, greatly improving the service life of the product: in normal operation, the contact can only stay in the closed
or open position.
5.3.2 High breaking capacity, up to 6000A.
5.3.3 Zero sequence transformer, electronic discrimination control circuit element
of residual current release with high performance, stable work, strong anti-
DZ45LE-100/4P
interference, ensure the reliable work of the product. mian circuit
5.3.4 With finger touch protection combination terminals, high safety. to other loads
5.3.5 The shell and parts are made of high flame retardant, high temperature
resistant and shock resistant plastic.
5.3.6 The products are small in size, light in weight, compact in structure and
modular in design. second circuit
DZ45LE-100/4P+N
5.3.7 Unique appearance, reasonable use of space layout.
5.3.8 The product adopts guide rail installation, it's convenient and time-saving. second circuit
DZ45LE-100/1P+N DZ45LE-100/2P DZ45LE-100/3P
5.4 As an example, the use of residual current operated circuit breakers in the
power grid is shown in Figure. The residual current operated circuit breaker can
also form a combined electric appliance with other electrical appliances to enlarge
the applicable range.

VI. Appearance and installation dimensions


Appearance and installation dimensions TH35-7.5 rail mounting dimensions

E 51 52 F
Suyang Quality, Rock Solid

SYCM1 Series Moulded Case Circuit Breaker SYCM1 Series Moulded Case Circuit Breaker
I.Range of Application
3. The current of the protective electric motor of the electromagnetic release is 12In±20%(A)
Moulded Case Circuit Breaker (MCCB)is one of the company's new circuit breakers which combined the international 4. If the applied voltage of the shunt release is between 70%~110% of the rated control power voltage, it can reliably
advanced design,manufacturing technology and develop . According to its rated limit short circuit sectional capacity (ICU), is breaking the circuit breaker.
divided into L-type (standard type), M-type (high break type), H-type (higher break type).It has the characteristics of small 5. When the supply voltage drops to the rage of 70%~35% of the rated working voltage of the under-voltage release,
size, high breaking, short flying arc and anti-vibration, and is an ideal product for land and ship use. Its rated insulation voltage the under-voltage release can reliably breaking the circuit breaker. If the supply voltage is below 35% of the normal-
800V (SYCM1-63 is 500V), suitable for AC 50HZ, 690V and the following circuit for continuous frequent conversion and motor voltage of the under-voltage release , the under-voltage release could prevent the breaker of closing; when the
infrequent start-up. Circuit Breaker has overload, short circuit and under-voltage protection device, which can protect the line supply voltage is above 85% of the rated working voltage of the under-voltage, the under-voltage could ensure the
and power equipment from being damaged.
breaking closing.
Vertical installation and horizontal installation
Meet the standards: IEC60947-2、GB14048.2
V. Appearance and Mounting Dimension
II.Types and Classification
flash barrier
SY CM A
A1 A1 flash barrier

Under-voltage release

Under-voltage release
G
H5

G1
H4
H3
Operation methods(2) F
F

Application code(1)

L1

C1
L2

E
B
L

C
22

E
Release Versions and Accessory codes 22

Pole
Rated limited short-circuit breaking capacity levels H2
H
Shell grade rated current W1 W1 W1
H1(max)
W2
Design NO. W1 W1
W
4P
Moulded Case Circuit Breaker
3P Table3
Yangzhou Suyang Electric Co., Ltd

Appearance dimension Mounting


dimension
III.Specification Specification Pole
C C1 E F G G1 H H1 H2 H3 H4 H5 L L1 L2 W W1 W2 A1 A B φd
Rated current of overcurrent release (A): respectively,SYCM1-63:(6)、 10、 16、 20、 25、 32、 40、 50、 63A; YX CM1-63L 3 85 / 48 22 14 6.5 74 90.5 28 4 6 / 135 235 117 76 25 / / 25 117 4.5
SYCM1-100:(10)、 16、 20、 25、 32、 40、 63、 80、 100A; SYCM1-250:100、 125、 140、 160、 180、 200、 225、 YXCM1-63 M 3 85 / 48 22 14 6.5 74 90.5 28 4 6 / 135 235 117 76 25 102.5 / 25 117 4.5
250; SYCM1-400:225、250、315、350、400A; SYCM1-630:400、500、630A; SYCM1-800:630、700、800A;
YXCM1-125L 3 84 / 50.5 22 17.5 7.5 68 86 24 4 7 / 150 255 136 90 30 / / 30 130.5 4.5x6
Note1: The 6A case only have the electromagnetic (instantaneous) type;
YXCM1-125M
Note2: the specifications in the parentheses are not recommended. 3 84 / 50.5 22 17.5 7.5 68 86 24 4 7 / 150 255 136 90 30 / / 30 130.5 4.5x6
YXCM1- 125H
YXCM1-250L
3 102 / 50 22 23 11.5 86 110 24 4 5 / 165 360 144 105 35 / / 35 126 5.5
IV.Technical Parameters YXCM1-250M
YXCM1-250H 3 102 / 50 22 23 11.5 103 127 24 4 5 / 165 360 144 105 35 140 / 35 126 5.5
1.Thermal magnetic circuit breaker has the inverse time characteristic, electromagnetic tripping is instantaneous
YXCM1-400L
action, characteristics refer to Table2(power distribution)
Table1 YXCM1-400M 3 127.5 173.5 88.5 65 30.5 11 105 155 38 6.5 5.5 5 257 457 224 150 48 / / 44 194 7
Thermal magnetic release (ambient air temperature+40℃) YXCM1-400H
Rated current Electromagnetic
of the release 1.05 In(cold state) 1.30 In(hot state) 3.0 In Returns the properties release tripping YXCM1-400L
no action time(h) action time(h) of the current return time(s) current(A)
YXCM1-400M 4 127.5 173.5 88.5 65 30.5 12 105 155 38 6 5 4.5 257 457 224 / 48 197.5 50 44 194 7
YXCM1-400H
YXCM1-630L
YXCM1-630M 3 134 184.5 89 65.5 44 13.5 110 160 43 7 3.5 4.5 270 470 234 182 58 / / 58 200 7
YXCM1-630H
2. Productive motor refer to Table3(ambient air temperature 40℃) YXCM1-630L
Table2
YXCM1-630M 4 134 184.5 89 65.5 44 15.5 110 160 43 6.5 3.5 4.5 270 470 234 / 58 240 58 58 200 7
Time
Testing current name The multiple of rated current Initial State YXCM1-630H
YXCM1-800L
Conventional non-tripping current Cold State 3 136 204 81 66 45 12.5 116 168 41.5 4.5 5 8 280 470 243 210 70 / / 70 243 7
YXCM1-800M
Hot State
YXCM1-800L 4 136 204 81 66 45 12 116 168 41.5 4.5 5 8 280 485 243 / 70 280 / 70 243 7
Conventional tripping current Hot State
YXCM1-1250M 3 / / 100 78 45 / 139 190 55 / / / 330 465 / 210 70 280 / 70 300 /
Cold State
YXCM1-1250M 4 / / 100 78 45 / 139 190 55 / / / 330 465 / 210 70 280 / 70 300 /

F 53 54 F
Suyang Quality, Rock Solid

SYCM1L Series Leakage Moulded Case Circuit Breaker


I.Range of Application
Moulded Case Circuit Breaker (MCCB)is one of the company's new circuit breakers which combined the international

SYCM1L Series Leakage advanced design,manufacturing technology and develop . According to its rated limit short circuit sectional capacity (ICU), is
divided into L-type (standard type), M-type (high break type), H-type (higher break type).It has the characteristics of small
size, high breaking, short flying arc and anti-vibration, and is an ideal product for land and ship use. Its rated insulation voltage

Moulded Case Circuit Breaker 800V (SYCM1-63 is 500V), suitable for AC 50HZ, 690V and the following circuit for continuous frequent conversion and motor
infrequent start-up. Circuit Breaker has overload, short circuit and under-voltage protection device, which can protect the line
and power equipment from being damaged.
Vertical installation and horizontal installation .
Meet the standards: IEC60947-2、GB14048.2.

II.Types and Classification

SY C
Alarms: both alarm and tripping is represented by I,
alarm without tripping is represented by II
4pole type code (see the below table), 3pole type has no code

Application codes: power distribution has no code, protective motor represented by 2.

Release Versions and Accessory codes

Pole:(3: 3 pole; 4: 4 pole)

Operation mode:
Manual operation type has no code;
Turning handle operation is represented by Z;
Motor operation is represented by D.

Breaker's breaking capacity levels:


Standard type is represented by L;
Higher breaking type is represented by M;
Highest breaking type is represented by H.

Shell grade
With leakage protection

Design NO.

Moulded Case Circuit Breaker

Yangzhou Suyang Electric Co., Ltd

III.Technical Parameters
Table 1 Release mode and accessories code
Release mode and
accessories code Auxiliary mounting and wiring connection mode

Accessories code Electromagnetic Complex SYCM1L-100/3□ SYCM1L-100/4□ SYCM1L-400 /□


release release SYCM1L-250/3□ SYCM1L-250/4□ SYCM1L-630、800/□

No accessories

Alarm contact
Shunt release

Auxiliary contact

Alarm contact
under-voltage release
Shunt release,
auxiliary contact
Leakage alarm mode I/II I/II

F 55 56 F
Suyang Quality, Rock Solid

SYCM1L Series Leakage Moulded Case Circuit Breaker SYCM1L Series Leakage Moulded Case Circuit Breaker
Appearance and mounting dimension of the circuit breaker rear connection
IV.The Conditions of Application,Mounting and Transportation
Normal condition of application:
a)The ambient air temperature is -5℃~+40℃, average temperature in 24 hours should less than +35℃.
Note: If the temperature is below -5℃ or above 40℃, consult the manufacturer before order
b)The elevation of the installation site should be less than 2000m.
c)The relative humidity of the atmosphere is not more than 50% when the ambient maximum temperature is
+40℃;and at lower temperatures there can be a higher relative humidity (eg. 20℃ 90%), take the condensation on
the surface of the product due to the temperature changes into account.

Appearance dimension(mm) Mounting dimension(mm)


Normal condition of mounting:
Specification
a)Mode: Vertical and horizontal.
3P 4P 3P 4P
b)Category: Circuit breaker main circuit is class III, control circuit and auxiliary is class II. SYCM1L-100
c)Pollution level: level 3. SYCM1L-250
d)External magnetic: the external magnetic field near the installation site should be 5 times less than the SYCM1L-400
geomagnetic field in any direction. SYCM1L-630、800
Appearance and mounting dimension of the wiring after inserting the board

V. Appearance and Mounting Dimension


Appearance and mounting dimension of the circuit breaker front connection

The hole size of the mounting board

(mm)

Specification
3P 4P 3P 4P
SYCM1L-100
SYCM1L-250
SYCM1L-400
SYCM1L-630、800

VI. Turning Handle Operation Module

Appearance
dimension Mounting dimension
Specification Pole
L1 L2 L3 L4 Mounting
a b holes(φ)
3 92 150 110 92 30±0.14 129±0.32 4-φ4.5
SYCM1L-100
4 122 150 110 92 60±0.14 129±0.32 6-φ4.5
The hole size of door
3 107 165 110 90 35±0.16 126±0.32 4-φ4.5 Emergency unlock
SYCM1L-250
4 142 165 110 90 70±0.16 126±0.32 6-φ4.5
VII. Turning Handle Operation Mounting Dimension
SYCM1L-400 4 198 257 147 110 94±0.20 194±0.43 6-φ7
SYCM1L-630/800 4 280 280 155 103 140±0.20 243±0.50 6-φ7 Specification SYCM1L-100 SYCM1L-250 SYCM1L-400 SYCM1L-800
Mounting dimension(H)

F 57 58 F
Suyang Quality, Rock Solid

SYCM1E Series Electronic Moulded Case Circuit Breaker


I.Range of Application

SYCM1E Series Electronic


SYCM1E Series Electronic Moulded Case Circuit Breaker (MCCB) is suitable for the AC 50HZ(/60HZ), rated
insulation voltage 800V, rated current up to 800A circuit, for infrequent conversion and motor infrequent starting. The
circuit breaker has overload long delay time, short delay time limit, short short time delay setting, short-circuit

Moulded Case Circuit Breaker


instantaneous and under-voltage protection function and residual current protection (optional), which can protect lines
and power equipment from being damaged. The circuit breaker Protection features complete, accurate, so it can
improve the reliability of power supply, avoid unnecessary power outages, and the "Z, B" type control have
communication interfaces, which can be "four remote" to meet the control center and automation system
requirements.
According to its rated limit short-circuit breaking capacity , the circuit breaker cloud be divided into M-type(the
higher type),H-type(the highest type).
The circuit breaker has the characteristics of small volume, high breaking capacity, short flying arc and anti-
vibration.
The circuit breaker can be installed vertically or horizontally
The circuit breaker has the function of isolation.
The circuit breaker could not be inverted into the line, in short, only allowed the 1,3,5 connect the power line, 2,4,6
connect the load line.
Standards:
1, IEC60947-1 and GB14048.1 "low-voltage switch-gear and control equipment-part 1th: General principles".
2. IEC60947-2 and GB14048.2 "low-voltage switch-gear and control Equipment-part 2nd: Low-voltage Circuit
Breakers" and Appendix F "Additional Tests for circuit breakers with electronic over-current protection".
3, IEC60947-5 and GB14048.5 "low-voltage switch-gear and control equipment-part 5th-1: control circuit
Electrical and switch components electromechanical control circuit electrical appliances."

II.Types and Classification

SY CM E

Specification
Release Versions and Accessory codes
Pole
Operation methods
Rated limited short-circuit breaking capacity levels
Shell grade rated current
Electronic tripping
Design NO.
Moulded Case Circuit Breaker
Yangzhou Suyang Electric Co., Ltd

III.Normal condition of application

1. Elevation:≤2000m.
2. The ambient air temperature:-5℃~+40℃.
3. Withstand the effects of humid air.
4. Withstand the effects of salt mist or oil mist.
5. Main circuit installation category is III, and the remaining auxiliary circuit,control circuit installation category is II.
6. When the highest temperature is +40℃,the relative humidity of the air should not more than 50%, and at lower
temperatures there can be a higher relative humidity , take the condensation on the surface of the product due to
the temperature changes into account.
7. Maximum tilt is 22.5°.
8. The medium with no explosion-dangerous and is not sufficient to corrode the metal and to destroy the insulating
gas and conductive dust.
9. The installation place without rain or snow.

F 59 60 F
Suyang Quality, Rock Solid

SYCM1E Series Electronic Moulded Case Circuit Breaker SYCM1E Series Electronic Moulded Case Circuit Breaker
IV.Main functions and features VI. Main technical performance instructions
Intelligent controller is the core component of MCCB, it is used in motor protection or distribution protection.
Measurement, protection, control and communication functions can protect circuit and power equipment from damages like
overload, short circuit and grounding fault.
1.Using MCU micro processing controller, stable and reliable performance: the intelligent controller can supply power,
as long as one pahse is power on, and the current is not less than 20% of its rated value, it can ensure the normal
operation of the protection function;
2.Selectivity coordination has three sections protection: circuit breaker used for B category and other short circuit
protection device connected on the same circuit has selective coordination; Overload long delay inverse time, short circuit
delay(inverse time, time limit), short circuit instantaneous protection function parameter setting;
3.Parameter settings of action current and action time three section protection is adjustable in 4-10 gear: users can
adjust the controller settings according to load current requirements, and select corresponding functions (customize the
function required to specify when ordering); Intelligent molded case circuit breaker

SYCM1LE-630M/3300

4.High current instantaneous trip function: when the breaker is in closed operation, and the current is a high short Ui 690V Ue 400V

circuit current (≥ 20lnm), the magnetic tripping mechanism of circuit breaker can be directly tripped, double protection is L
Icu
50kA
Ics
35kA
GB 14048.2
IEC60947-2

more reliable and safe; M 65kA 42kA

H 100kA 65kA
5.Tripping test function: make the voltage of input circuit is DC12V; Ir1 400A-630A PUSH TO TRIP
Uimp 6kV

Cat:A 50Hz
In 630 A

6.Fault self-diagnosis function: to protect and detect working state and operation condition of the intelligent controller; Yangzhou Suyang Electric Co., Ltd.

7.Pre-alarm and overload indicator: When the load current reaches or exceeds the set value, corresponding light
source is derived; TEST
20
25
60
80 4
5
6 0.1
0.2 8
10
11
0.85
0.9
0.8
7 12

8.Double air gap technology of flux transfer trip: The utility model has the advantages of more reliable and stable
16 12 3 7 0.95
0.06
0.75
2.5 8 6 13
10 14 0.7 1
100 2 0.3 4
32 OFF 12 OFF OFF

Ir1(A) Ir2(XIr1) Ir3(XIr1) Ir0(XIr1)

operation, no misoperation, reliable tripping, and small power;


9.High precision protection: action time accuracy of overload protection, short-circuit short delay protection is ±10%;
action value accuracy of instantaneous short circuit protection is±15%;
10.The installation has interchangeability: appearance dimension and installation dimension are the same as SYCM1
MCCB which is the same dimension.

V. Product function configuration table

Product SYCMIE SYCMIE(Z) SYCMIE(B) SYCMIE(X) SYCMIE(L) Model SYCMIE-125 SYCMIE-250 SYCMIE-400 SYCMIE-630 SYCMIE-800
type Programming type
Function Basic type Intelligent type Fire type Liquid crystal type
Overload and long Inm(A) 125 250 400 630 800
time delay setting
16/20/25/32/36/ 400/420/440/460/ 630/640/660/680/
Short circuit and short 40/45/50/55/60/ 125/140/160 200/250/280/
time delay setting In(A) 63/70/75/80/85/ 180/200/250 315/350/400
480/500/530/560/ 700/720/740/760/
90/95/125 600/630 780/800
Short circuit and
instantaneous setting
Overload and Ue(v) AC400V
pre-alarm indication
Ui(v) AC800V
Tripping test function

Fault self-diagnostic Uimp AC8000V


function
Poles 3 4 3 4 3 4 3 4 3 4
Code switching setting / /
Rated ultimate short-circuit
Two-way passive signal breaking capacity level M H M H M H M H M H
output /
Icu(kA) 50 80 50 50 85 50 65 100 65 65 100 65 65 100 65
Communication module /
Ics(kA) 35 50 35 35 50 35 42 65 42 42 65 42 42 65 42
Hand-held programmer /
Icw(kA)1s / / 5 8 10
Encoding setting /
Using sorts A A B B B
Shunt function /
Temperature monitoring Operation Power on 3000 3000 2000 1500 1500
and protection function / performance
(time) Power off 7000 7000 4000 3000 3000
Memory function /
L 150 165 257 280 280
Intelligent control module /
Appearance
W 92 122 107 142 150 198 210 280 210 280
Fire protection function / / / / dimension
H 92 90 106.5 115.5 115.5
LCD / / / /
Arcing distance ≤50 ≤50 ≤106.5 ≤100 ≤100
basic function optional function

F 61 62 F
Suyang Quality, Rock Solid

SYCM1E Series Electronic Moulded Case Circuit Breaker SYCM1E Series Electronic Moulded Case Circuit Breaker
VII. Appearance and installation dimension Appearance and installation dimension of circuit breaker rear-panel wiring

Appearance and installation dimension of circuit breaker front-panel wiring

5 10 0.85
20 60 6 0.1 11 0.9
25 80 4 0.2 8
0.8
3 7 7 12 0.95 5 10 0.85
16 12 0.06 20 60 6 0.1 11 0.9
25 80 4 0.2 8
0.75 0.8
2.5 8 6 13 3 7 7 12 0.95
16 12 0.06
10 14 0.7 1 0.75
100 2 0.3 4 2.5 6
32 OFF 12 OFF OFF 8 13
10 14 0.7 1
100 2 0.3 4
Ir1(A) t1(S) Ir2(XIr1) t2(S) Ir3(XIr1) Ir0(XIr1) 32 OFF 12 OFF OFF

Ir1(A) t1(S) Ir2(XIr1) t2(S) Ir3(XIr1) Ir0(XIr1)

Appearance dimension Installation dimension


Model
3P 4P 3P 4P
SYCM1E-63 140 75 15 30 48.5 25 50 104 117 18 6.8
S YCM1E-125 34 80 30 60 104 117 23 4.5
SYCM1E-250 59.5 89.5 35 70 126 144

Appearance dimension Installation dimension SYCM1E-400 279 224 35 42 75 44 88 194 244 32


Model Poles SYCM1E-630 299 234 60 38.5 73.5 58 116 200 234 38
L1 L2 L3 L4 a b Installation hole (φ) SYCM1E-800 304.5 243 88 92.5 148 70 140 243 243 38

3 78 142 90.5 73.5 25±0.14 117±0.32 4-φ3.5


SYCM1E-63
4 103 142 98.5 81.5 50±0.14 117±0.32 4-φ6.8

3 92 150 110 92 30±0.14 129±0.32 4-φ4.5 VIII.Rotational handle operation module


SYCM1E-125
4 122 150 110 92 60±0.14 104±0.32 6-φ4.5

3 107 165 110 90 35±0.16 126±0.32 4-φ4.5


SYCM1E-250
4 142 165 110 90 70±0.16 126±0.32 6-φ5.5

SYCM1E-400 3 150 257 146.5 106.5 44±0.20 194±0.43 6-φ7

SYCM1E-400 4 198 257 146.5 106.5 88±0.20 243±0.50 6-φ6.5

S YCM1E-630 3 182 270 150 110 58±0.20 200±0.50 6-φ7


The hole size of door
Emergency unlock
SYCM1E-630 4 240 270 150 110 116±0.20 200±0.50 6-φ7

S YCM1E-800 3 210 280 155 115.5 70±0.20 243±0.50 6-φ7

SYCM1E-800 4 280 280 155 115.5 140±0.20 243±0.50 6-φ7 IX. Rotational handle installation dimension

Model SYCM1E-63 SYCM1E-125 SYCM1E-250 SYCM1E-400 SYCM1E-630


Installation Metal 51 52 56 88 88
dimension
(H) Plastic 69 69 72 110 110

F 63 64 F
Suyang Quality, Rock Solid

SYDW45 Series Intelligent Air Circuit Breaker


I. Scope of application

SYDW45 Series
SYDW45 series intelligent air circuit breaker (hereinafter referred to as breaker), it is suitable for distribution network
which is AC 50Hz, rated voltage up to 660V (690V) and below, 630A~6300A rated current. It is used in distribution of
power and protecting circuit from overload, short circuit, undervoltage, single-phase grounding fault hazard. Circuit breaker

Intelligent Air Circuit Breaker with intelligent protection function and precise selective protection can improve the reliability of power supply, avoid
unnecessary power outages. And it has an open communication interface, can carry out the "four remote", in order to meet
requirements of the control center and the automation system. The circuit breaker pulse pressure is 8000V at an altitude of
2000 meters (different altitude correction according to the standard, the maximum is not more than 12000V). This circuit
breaker has no intelligent controller or sensor, can used for identification of the isolator. Identification:
The circuit breaker complies with GB14048.2 “low voltage switchgear and control equipment, low voltage circuit
breaker” and IEC60947-2“ low voltage switchgear and control equipment, circuit breakers” etc.

II. Type definition and classification

Types and Classification


SY DW 45

Poles (4p: 4, 3p:no mark)


Frame rated current of the circuit breaker
DesIgn code
Air circuit breaker
Yangzhou Suyang Electric., Ltd.

classification
Classified by installation:
a.Fixed
b.Open frame
Divided by poles: 3p、4p
According to the operation mode:
a.Electric operation
b.Manual operation ( maintenance)

Release type
Intelligent controller, under voltage instantaneous (or delayed) release, shunt release.

The performance of intelligent controller


a. Intelligent controller is divided into: H (Communication), M (general intelligent), L (economical)
b. With overload long delay inverse time delay, short time limit, inverse time, instantaneous function.
Users can set their own protection characteristics which is needed;
c. Single-phase grounding protective function
d. Display function: setting current, operating current, each phase voltage value is displayed (voltage
display should be presented when ordering).
e. Alarm function: overload alarm.
f. Self check function: overheating self-test, microcomputer self diagnosis.
g. Test function: operating characteristic of test controller

G 65 66 G
Suyang Quality, Rock Solid

SYDW45 Series Intelligent Air Circuit Breaker SYDW45 Series Intelligent Air Circuit Breaker
III. Main technical parameters 5. Ground fault protection characteristics for the short delay and constant time-lag, see Table 5 limit action time and
return time, ground fault factory time setting for "OFF".
1. The basic parameters of the circuit breaker is shown in Table 1 Table 1 6. The operation performance of the circuit breaker is represented by the number of operation cycles, see Table 6.
Frame Size Rated ultimate short- Rated operation short- Rated short time Power loss(w) Table 6
Rated voltage
Rated Current Rated current circuit breaking capacity circuit breaking capacity withstand current Open
Fixed frame Number of operation Mechanical life (Times) Electrical life
Inm(A)
cycles per hour Mnintenance-free Mnintenance (Times)
2000 20 13500 20000 6500
400/690V
3200 20 10000 20000 3000

4000 15 5000 10000 1500


50/40 6300 10 5000 10000 1000

5. Working voltage of shunt release, undervoltage release, electric operating mechanism, release (closing) electromagnet,
intelligent release for circuit breaker is shown in Table 7.
Table 7
80/50
Rated voltage
Type

80/50
Shunt release

Undervoltage release
Electric operating mechanism
100/75
Release (closing) electromagnet
Intelligent release
Note 1: the arcing distance is zero. Note 2: the breaking capacity of upper and lower line are the same.

The derating coefficient of circuit breaker at different ambient temperature see Table 2 Note: Reliable operation voltage range of shunt release is (70%-110%) Us, release (closing) electromagnet and the
Table 2
electric operating mechanism is (85%-110%) Us.
Ambient temperature
Allowable continuous 8. Performance of circuit breaker under voltage release is shown in Table 8
working current Table 8
Note: in various ambient temperature conditions, measured circuit breaker import terminal temperature reached 110℃ as a benchmark. Type Undervoltage delay release Undervoltage instantaneous release
2. Release current setting Ir and tolerance are shown in Table 3 Table 3 Release action time Delay 1、3、5 s Instantaneous
Long time Short time delay(Ir2) Instantaneous(Ir3) Ground fault(Ir4)
break the circuit breaker
delay(Ir1) L-type M、H-type Tolerance L-type M、H-type Tolerance Tolerance
Release action time Circuit breakers are not closed
Maximum:1200A
Minimum:160A Circuit breaker can be reliably closed

In 1/2 delay time, if the supply Circuit breaker is not breaking


voltage is restored to 85%Ue
Note: when the three section protection, the setting value can not cross
Note: accuracy of delay time is + 10%
3. Long time delay characteristic protection tripping current is shown in Table 4 Table 4

Action time Tolerance 9. The performance of auxiliary contact


>2h No action 9.1 6A Conventional thermal current of auxiliary contact is 6A
<1h Action 9.2 Auxiliary contact form: four group conversion
9.3 Abnormal connection and breaking capacities of auxiliary contact

Making and breaking capacity of auxiliary contacts in abnormal operating conditions


Note: 2.0Ir1 time is calculated byI2T=(1.5Ir1)2tL, where tL is 1.5Ir1 when the action time setting by the user. Table 9

Connect Breaking Number on-off operation


4. Short time delay over current protection action characteristics are shown in Table 5 Table 5 cycles and operation frequency
Number of
Delay setting time ts(s) 0.1 0.2 0.3 0.4 Using sorts Number of operation Power-on
or or operation cycles time
Delay time (s) 0.06 0.14 0.23 0.35 cycles per minute

I> 8Ir1 Time limit action or the same


frequency as
Action characteristics 2 main circuit
( 8Ir1 ) ts I=short-circuit current operation
I< 8Ir1 T= T=Action time
I2

G 67 68 G
Suyang Quality, Rock Solid

SYDW45 Series Intelligent Air Circuit Breaker SYDW45 Series Intelligent Air Circuit Breaker
IV. Basic function of M or L type controller V. Installation and appearance dimention of fixed circuit breaker
Connecting terminal SYDW45-2000、2000/4 fixed circuit breaker (see Figure 2)
There are 47 connecting terminals in circuit breaker, it is simple and easy to use, the wiring diagram is shown in Figure 1.
Other connection of intelligent controller 413(4P)
318(3P) Cupboard door

#1, #2 are working power input


#25, #26 are external connection of neutral pole or current transformer input

Main Intelligent controller Emergency Motor-driven Motor-driven Auxiliary switch


circuit cut-off cut-off close
340(3P)

435(4P) (Vertical wiring)


Fault Close Energy Disconnect
storage

340(3P)

435(4P)
Control (Extended horizontal wiring)
power supply
Processing Figure 2
unit

85 29
95
105
Working
power
DC power module (SYDW45-3200、3200/4)fixed circuit breaker (see Figure 3)

493(4P)
Figure 1 378(3P)
Cupboard door

Note:
(1) If control power supply voltage of F, X and M is different, power supply is different.
(2) Terminal #35 can be directly connected to the power supply (automatic pre storage), also can be connected with
power supply when it is cascaded with a normally open button (manual pre storage). 86

(3) Terminal #6~#7 can output normally closed contact as users' requirements. 400(3P)

(Vertical wiring)
(4) Accessories are prepared by user. 515(4P)

(5) When working power supply of intelligent controller is DC power, general configuration is “built in” ( none
specified) DC power supply module, Terminal #1, #2 can be directly connected to the DC power. If users select "plug-
in" module, terminal #1, #2 can not be directly connected to the DC power, and DC power supply must be input from the

400(3P)

515(4P)
DC power module U1 (+), U2 (-), the two output terminals are respectively corresponding connect to the secondary
86
wiring terminal input 1 (+) and 2 (-).

(Extended horizontal wiring)


SB1 shunt button (prepared by user) X closing electromagnet DF auxiliary contact Q undervoltage release or
Figure 3
undervoltage delay release
SB2 undervoltage button (prepared by user) Menergy storage motor F shunt release O normally open
contact (3A/AC380V)
SB3 closing button (prepared by user) XT connection terminal SA motor microswitch Signal lamp (prepared
by user)

F
G 69 70 G
Suyang Quality, Rock Solid

SYDW45 Series Intelligent Air Circuit Breaker SYDW45 Series Intelligent Air Circuit Breaker
VI. Installation and appearance dimention of open frame circuit breaker SYDW45-4000 open frame circuit breaker (see Figure 6)

SYDW45-1000、2000/3、4 open frame circuit breaker (see Figure 4) Cupboard door

430(4P) Cupboard door


335(3P)
42.5

42.5
461(connect) 494(connect)
507(separate) 540(separate)
375(3P) (Vertical wiring) 559(connect)
470(4P)
605(separate)

Note: size from panel


center to breaker
Center is about 57.5
265(3P)

202.5 202.5
360(4P)

15
(Extended horizontal wiring)

50
Figure 4
Figure 6

SYDW45-4000/4 open frame circuit breaker (see Figure 7)


SYDW45-3200、3200/4 open frame circuit breaker (see Figure 5)

Cupboard door
510(4P)
395(3P)

452
45.5

461(connect)

42.5
504(connect)
507(separate)
550(separate)
c (connect)
435(3P)
559(connect)
d (separate)

90
550(4P) 615(separate)
(Vertical wiring)
Note: size from panel
center to breaker
Center is about 206.5
325(3P)
440(4P)

155

15
(Extended horizontal wiring)

50
Figure 5 (Horizontal wiring)

Figure 7

G 71 72 G
Suyang Quality, Rock Solid

SYDW45 Series Intelligent Air Circuit Breaker SYDW45 Series Intelligent Air Circuit Breaker
SYDW45-6300、6300/4 In=4000A、5000A open frame circuit breaker (see Figure 8) SYDW45-6300、6300/4 In=6300A open frame circuit breaker (see Figure 10)

952(4P)
335(3P) 888 Cupboard door
Cupboard door 1067
837(3P)
773 1003

452
452

42.5

42.5
504(connect)
504(connect)
550(separate)
550(separate)
569(connect)
569(connect)
615(separate)
813(3P) 615(separate)
1043
928(4P)
Note: size from panel
Note: size from panel center center to breaker
to breaker Center is about Center is about 304
189(3P), 264.5(4P)

In=4000A,The thickness of
60
wiring copper bar:20mm
703(3P)

818(4P)

200 286.5 286.5

100

1037
938
50 28

50
N
(Horizontal wiring)
(Horizontal wiring)

Figure 8
Figure 10

Specifications and quantity of connecting copper bar (see table below)


SYDW45-6300 In=6300A open frame circuit breaker (see Figure 9)

Rated External Quantity of Rated External Quantity of


Cupboard door
copper bar each pole copper bar each pole
current specifications current specifications
630A 40X5 2 2900A 100X10 3

800A 50X5 2 3200A 120X10 3


452

1000A 60X5 2 3600A 120X10 4


42.5

504(connect)
550(separate) 1250A 80X5 2 4000A 120X10 4
569(connect)
615(separate)
1600A 100X5 2 5000A 120X10 5
Note: size from panel
center to breaker 2000A 100X5 3 6300A 120X10 6
Center is about 264.5
2500A 100X5 4
50

(Horizontal wiring)

Figure 9

G 73 74 G
Suyang Quality, Rock Solid

SYDW45 Series Intelligent Air Circuit Breaker


VII. Door frame size and installation hole spacing

SYG1 Series Auto


over/under Voltage Protector
19 . 5

19 . 5
268

51 16

Fixed Bottom of circuit breaker Open frame

Inm a mm b mm c mm
2000 306 345 0
3200、4000/3 366 405 0
4000/4 306 345 0
6300 366 405 0

Installation and appearance dimention of fixed circuit breaker

241 241
Current Current
specification specification 205
7 50 55 50
5000A 30
25
50
50

134

4000A 20

(Horizontal wiring)
395

134
112
55

base point
150 69.5 196
11 778(3P) 11
285 11
898(4P)
290

G 75 76 H
Suyang Quality, Rock Solid

SYG1 Series Auto over/under Voltage Protector SYG1 Series Auto over/under Voltage Protector
I. Product overview IV. Connection diagram V. Appearance and installation dimention
load load
SYG1 series auto over/under voltage protector (hereinafter referred to as protector) is a high-tech new product 35 66 66
74
developed with the latest technology. When the power supply line is over voltage and under voltage, the protector can
cut off the circuit rapidly and safely, to avoid abnormal voltage into the terminal resulting in accidents. When the

down-in and up-out


Auto over/underVoltage Delayed Protector
Auto over/under
voltage is returned to normal, the protector will automatically switch on the circuit in the given time to ensure the Voltage Protector
SYG1-40 IN:40A
Rated current:40A
Working voltage:AC380V 50Hz Auto over/under
Auto over/underVoltage Delayed Protector
Rated current:40A
Overvoltage protection:AC460V±15V Voltage Protector

normal operation of the terminal. Protector is suitable for single phase AC voltage 220V, frequency 50Hz, rated 270±5V Overvoltage Working voltage:AC380V 50Hz
Undervoltage protection:AC300V±15V SYG1-40 IN:40A Overvoltage protection:AC460V±15V
170±5V Undervoltage Delay Time:≤60S 270±5V Overvoltage Undervoltage protection:AC300V±15V

84

84
Delay Time:≤60S

81
operating current 90A loads.The protection of single-phase power supply equipment caused by single-phase line 1-2min Delayed protect 170±5V Undervoltage

AC220V Power Supply Power Supply protect


1-2min Delayed

Yangzhou Suyang Electric Co., Ltd. Power Supply

over voltage due to neutral line fault is mainly used for the protection of the distribution line of the household, Yangzhou Suyang Electric Co., Ltd. AC220V Power Supply

Yangzhou Suyang Electric Co., Ltd.


Yangzhou Suyang Electric Co., Ltd.

household box, incoming line or single-phase electric equipment.

II. Normal working conditions and environment AC220V AC380V


SYG1 single phase SYG1 three-phase
single phase three-phase
Note: up-in and down-out or down-in and up-out is
Ambient air temperature: set according to customer requirements.

a) The ambient air temperature shall not exceed +40℃, and the temperature within 24h shall not exceed +35℃;
b) The ambient air temperature limit is -5℃. VI. Structure features and working principle
Altitude:≤2000m;
1、 When the single-phase line is under voltage, the circuit is cut off, the single-phase voltage is restored to normal,
Atmospheric condition:
then is reset automatically after the delay, without manual operation.
When the maximum temperature is +40℃, the relative humidity of the air should not exceed 50%.
2、When the line appears transient or transient over-voltage, the protection will not cause misoperation.
Lower temperatures permit higher relative humidity, such as 90%. at 20 degrees, and appropriate measures should 3、The line is out of contact, then it causes the unstable voltage or a sudden power failure followed by a sudden call, the
be taken for the occasional condensation due to temperature changes. protector does not switch on the circuit.
Pollution level: 3 4、When the line fault voltage is the highest, the protector itself is not damaged.
In a medium that has a weatherproof device and is free from explosion, there is not enough gas in the medium to 5、Voltage protection range: <40A: 0-450V; 50A/63A: 0-600V.
corrode the metal and destroy the insulation, and there is a lot of conductive dust; 6、Indicator lamp: four double color LED light-emitting diode respectively: normal (green), delay (yellow), overvoltage
The installation surface and the vertical inclination are not more than ±5℃, installed and fixed in places where there is (green), undervoltage (blue).
no significant shaking or impact vibration. 7、Installation method is the same as DZ47 (C45) miniature circuit breaker which is the same size with it, it is directly
Installation category: III connected with the switching device in series, used in the main circuit. Easy installation, low power consumption, long
service life.
8、The auto over/under voltage protector is sampling and comparing with the integrated chip to determine whether the
input voltage of the main circuit is abnormal, if the circuit is abnormal then trigger protective circuit, it disconnect the main
III. Model and technical parameter circuit load through the built-in relay, and the protector enters the power-off protection state until the input voltage
returns to normal range, start delay 1 minutes after coincidence.
SY G1 -
Rated working voltage VII. Installation and use
Rated current of main circuit
S:36mm width(The connection mode is down-in and up-out) Installation: Standard 35mm rail installation. If the product appearance and size similar to DZ47, it can be
auto over/under voltage delayed protector merged installation.
Read the instruction manual before installation, and then according to the wiring diagram on line. The
Yangzhou Suyang Electric., Ltd.
protector marked on the inlet end and the outlet end of the English letter "N" indicates the zero line, "L" phase,
"IN" into the line side, "OUT" represents the outlet end.
Main technical data and parameters (see table below) Instructions of SYG1 auto over/under voltage delayed protector : when the power supply is connected, the
Product model SYG1 auto over/under voltage delayed protector power indicator lamp and the time delay protection lamp are simultaneously lighted, and the controller is in the
Work power AC220V 50/60Hz detection voltage state. When the voltage of power supply is normal, after the delay protection, the control
Protected type Over voltage protection, under voltage protection terminal is provided with power output, and the main circuit is loaded with electricity. In the process of use,
Protection parameter Overpressure value:AC275±5V;AC175±V(Special requirements can be customized) when the overvoltage or undervoltage, the corresponding indicator light, delayed protection open, until the
Action delay time 1S~6S voltage returned to normal when the start time, 30~60s coincidence, load power.
Protection time of SYG1 series auto over/under voltage protector is 1s, and can turn off power supply. The
Reclosing time 30S~60S(Start clocking after the voltage has returned to normal)
second automatic transmission starting from the voltage returns to normal and starts timing in 1min. The over -
Turn on Delay Time 2S
Restore power supply undervoltage range protected by the protector is fixed at the factory, we can customize according to your
parameters Overvoltage recovery difference:242±5V Undervoltage recovery difference:187±5V
special requirements.
Product power consumption ≤2VA
contact rating 250VAC 20A/250VAC 30A(Resistance)
Connection mode up-in and down-out/down-in and up-out
Use type AC-15 DC-13 VIII.Storage conditions of protectors
Mechanical life 10 6 times
Installation method 35mm rail mounting (Combination installation with DZ47) Temperature: -25℃~+40℃;
Relative humidity (25℃) ≤ 85%;
Keep away from rain and snow.

H 77 78 H
Suyang Quality, Rock Solid

SYL1-B Series Surge Protection Device


I. Product Description

SYL1 Series
SYL1-B/4-60KA、 SYL1-B/4-80KA、 SYL1-B/4-100KA Series SPDs are suitable for TT、IT、TN-S、TN-C、
TN-C-S power supply systems (AC 50/60Hz,≤380V), they are used in equipotential bonding at the interface between
LPZ0A or LPZ0B and LPZ1, to protect the power grid from lightning strike or surge overvoltage. This SPD is designed

Surge Protection Device according to IEC-61643-1、 GB5007-94, it can discharge 100kA thunder-strike current, the shell is installed in a
35mm guide rail, these's a internal failure release device, when the SPD with a breakdown failure due to overcurrent and
overheating, the device can separate it from the grid and the status indicator displays from green to red.

II. Product Features


1.Use temperature control circuit breaker technology, internal overcurrent and failure release device, safe and reliable,
no latent fire hazard;
2.Visible window: green indicates operational, red indicates failure ( must be replaced immediately);
3.Optinal Functions: Adjust Alarms, Audible and visual Alarm, Remote SMS Contacts;
4.Common-Mode and Different-Mode, All-directional Protection for AC system;
5.Max on-load lightning impulse is 120kA (8/20μs), response time of protective action is less than 25 ns;
6.Plug & Play, replace the protection module without power outage.

III. Installation and Application


B-level lightning current SPD is used in equipotential bonding under lightning, it is installed at the
interface between LPZ0A or LPZ0B and LPZ1, and is usually mounted at the low-voltage incoming lines
main distribution panels.

IV. Technical Parameters

Model SYL1-B/4-60 SYL1-B/4-80 SYL1-B/4-100

Protection Class

Test basis IEC61643-1

Un(V)

Uc(V)

Ip(10/350μS)(kA)

Q(As)

(8/20μS)In(kA)

(8/20μS)Imax(kA)

Up(kA)

SYL1-B SYL1-B SYL1-B SYL1-B T(ns)

Protection Class basis IEC529(1989)

Temp(℃)

Shell Color Module/Base orange/gray orange/gray orange/gray


35 hard wire 35 hard wire 35 hard wire
Maximum Cable Diameter(mm²)
or 35 strand wire or 35 strand wire or 35 strand wire
L、N16 hard wire, L、N16 hard wire, L、N16 hard wire,
L.N/PE(mm²)
PE25 hard wire PE25 hard wire PE25 hard wire
Recommended Selection of Fuses

Installation 35mm electric guide rail 35mm electric guide rail 35mm electric guide rail

I 79 80 I
Suyang Quality, Rock Solid

SYL1-C Series Surge Protection Device SYL1-D Series Surge Protection Device
I. Product Description I. Product Description
SYL1-C Series SPD is suitable for TT、 IT、 TN-S、 TN-C-S power supply systems (AC 50/60Hz,≤ SYL1-D Series SPD is suitable for TT、 IT、 TN-S、 TN-C-S power supply systems (AC 50/60Hz,≤
380V), it is used in equipotential bonding under lighting. This SPD is designed according to IEC61643-1、 380V), it is used in equipotential bonding under lighting. This SPD is designed according to IEC61643-1、
GB5007-94, the shell is installed in a 35mm guide rail, these's a internal failure release device, when the SPD GB5007-94, the shell is installed in a 35mm guide rail, these's a internal failure release device, when the SPD
with a breakdown failure due to overcurrent and overheating, the device can separate it from the grid and the with a breakdown failure due to overcurrent and overheating, the device can separate it from the grid and the
status indicator displays from green to red. status indicator displays from green to red.

II. Product Features


II. Product Features
1.Use temperature control circuit breaker technology, internal overcurrent and failure release device, safe
and reliable, no latent fire hazard; 1.Use temperature control circuit breaker technology, internal overcurrent and failure release device, safe
2.Visible window: green indicates operational, red indicates failure ( must be replaced immediately); and reliable, no latent fire hazard;
3.Optinal Functions: Adjust Alarms and Remote SMS Contacts; 2.Visible window: green indicates operational, red indicates failure ( must be replaced immediately);
4.Common-Mode and Different-Mode, All-directional Protection for AC system; 3.Optinal Functions: Adjust Alarms and Remote SMS Contacts;
5.Max on-load lightning impulse is 40kA (8/20μs), response time of protective action is less than 25 ns; 4.Common-Mode and Different-Mode, All-directional Protection for AC system;
6.Plug & Play, replace the protection module without power outage. 5.Max on-load lightning impulse is 20kA (8/20μs), response time of protective action is less than 25 ns;
6.Plug & Play, replace the protection module without power outage.
III. Installation and Application
C-level lightning current SPD is used in equipotential bonding under lightning, it is installed at the interface
between LPZ0B or LPZ1 and LPZ2, and is usually mounted in floor distribution box、 computer center、 III. Installation and Application
telecommunications room、elevator control room、cabble television room、building automation room、security control
center、 fire center、 industrial automatic control room、 frequency conversion equipment control room、 operating D-level lightning current SPD is used in equipotential bonding under lightning, it is installed at the interface
room、 ICU and distribution boxes of other places which equipped with electromedical equipments. The SPD can be between LPZ1、 LPZ2 and LPZ3, and is usually mounted in household distribution box, computer center, the
also mounted in general lighting distribution box of residential buildings (less than 6 layers) and household distribution
nearest socket boxes of information appliance、electronic equipment and control equipment.
box, SPDs in decentralized cottages should be mounted in distribution box.

IV. Technical Parameters IV. Technical Parameters

Model SYL1-D
Model SYL1-C

Protection Class Protection Class

Test basis IEC61643-1 Un(V)

Un(V) Uc(V)

Uc(V) Maximum Fuse Strength(A)

Protection Level Up(kV) (8/20μS)In(kA)


(8/20μS)In(kA) (8/20μS)Imax(kA)
(8/20μS)Imax(kA)
Protection Level Up(kV)
T(ns)
Temp(℃)
Temp(℃)
T(ns)
Shell Color Module/Base Module: orange-gray/Base: gray
Maximum Cable Diameter(mm²) 35 hard wire or 35 strand wire
Shell Material Reinforced flame retardant PBT
L.N/PE(mm²) 6 hard wire/10 hard wire
Maximum Cable Diameter(mm²) 35 hard wire or 35 strand wire
SYL1-D SYL1-D
Maximum Cable Diameter of 1.5 hard wire
L.N/PE(mm²) 16 hard wire/25 hard wire Remote Monitoring Terminal (mm²)
SYL1-C SYL1-C SYL1-C SYL1-C

Maximum Cable Diameter of Shell Color Module/Base yellow/gray


Remote Monitoring Terminal (mm²) 1.5 hard wire

Maximum Fuse Strength(A) Shell Material Reinforced flame retardant PBT

Installation 35mm electric guide rail Installation 35mm electric guide rail
Common Model SYL1 SYL1 Common Model SYL1 SYL1
Alarm Model SYL1 Alarm Model SYL1 SYL1
Remote Control Contact Model SYL1
Remote Control Contact Monitoring SYL1 SYL1
Single-phase Bipolar Combined
into A single phase system SYL1

I 81 82 I