SUYANG
SUYANG
SUYANG
PRODUCT
SELECTION
GUIDE
Suyang Products are widely used in various fields like electric power, ship
transport, high-rise building and residential. The products meet our customer's
need from design, development, performance to moulding and so on because
we always take user requirements as guidance. Suyang has passed the
ISO9001 quality management system certification, TUV certification and
accreditation mandatory CCC, and all of our products meet CE and ROHS
standards.
CONTENTS
E High Breaking Miniature Circuit Breaker 45-51
SYDZ47LE-125 Series 50
SYK1/K2 Series Automatic Transfer Switch 01
14
F Moulded Case Circuit Breaker 52-64
SYS1 Series Manual Transfer Switch 17 SYCM1 Series Moulded Case Circuit Breaker 52
C
65
Switch-Disconnector-Fuse 26-32
H
26
Auto over/under Voltage Protector 76-78
SYR1-63A~1250A Switch-Disconnector-Fuse 28
Overall and Installation Dimensions of SYR1-63A~400A 29 SYG1 Series Auto over/under Voltage Protector 76
81
SYCPS Control and Protection Switch 33
SYL1-D Series Surge Protection Device 82
Suyang Quality, Rock Solid
SYK1/K2 Series
SYK1/K2 Series Automatic transfer switch is suitable for rated voltage 690V, rated frequency 50/60HZ,
rated voltage 440V and below, rated current of 16A-4000A, the main power supply system for power supply,
mainly used between in the two powers in the emergency case of the power supply system , in order to make
Automatic Transfer Switch sure the main load of emergency lighting, emergency elevator, lampblack machine to keep continuous and
reliable work. It would be widely used for providing uninterrupted and normal power supply for high-rise
buildings, hospitals, banks, highways, railways, etc..
Meet the standards:
IEC60947-1/GB/T14048 <The General Provisions on low-voltage switch and control equipment>
IEC60947-3/GB 1404.8.3 <Low-voltage switch and control equipment, low-voltage switches, isolators ,
disconnecting switches and fuse combinations>
IEC60947-6-1/GB14048.11 <automatic transfer switch appliance>
SY K
Pole
A(Automatic-type)S(Distance-type)E(Generator-type)L(Double Load)
Rate current
Design No.
Automatic transfer switch
Yangzhou Suyang Electric CO., Ltd.
IV.Working condition
A 01 02 A
Suyang Quality, Rock Solid
SYK1/K2 Series Automatic Transfer Switch SYK1/K2 Series Automatic Transfer Switch
V. Technical Parameters VII. Mounting Dimension
L1
Meet standard : IEC947-6-1/GB 14048. 11 L2
Horizontal hole center Auxiliary horizontal Lengthways hole Auxiliary lengthways Hole diameter
Current (A) distance L1 hole center distance L2 center distance H1 hole center distance H2 (mm)
Rated thermal
current(Ith) 80A 100A 125A 160A 250A 400A 6 3 0 A 8 0 0 A 1000A 1250A 1600A 2000A 2500A 3200A
(mm) (mm) (mm) (mm)
Rated isolation H2 2000-3200 475 150 350 220 13
voltage (Ui) 750V 1000V H1
Net weight 3.4 3.4 5 .2 5 .2 8 .1 1 5 .8 1 6 .0 3 6 .5 3 6 .8 37 44 96 105 108 SYK2-20-100A 245 126 233 84 14 30 6 133
Gross weight 4 .0 4 .0 6 .0 6 .0 9 .6 1 9 .0 1 9 .0 42. 0 4 2 .5 43 50 102 SYK1-20-160A 290 166 278 20 36 9 184
D
SYK1-200-300A 355 187 335 25 50 184
B
I road connect
the main power
VIII. Typical wire connection mode
201-206 ATS control terminals
SYK Series typical control schematic diagram
101-106 Control power terminals
of in-put and out-put
Note:1,This drawing is only
Standby power Main power
applicable to the standard
ATS using which under the
Safety guard board
301-306 working status terminals situation of the voltage is
POWER POWER
I road closing indicator
AC380V/220V (three phases 2 1
Status indication four wires),and frequency is I road 2 road 0 road closing indicator
Use the hand shank to R S T N U V W N power power
50/60HZ. indicator indicator
switch in manual type LED Indicators
2 4 6 8 2 4 6 8
2road closing indicator
2,When using the intelligent Q2 Q1
Auto/Manual electrical interlock
controller ,please use the
1 3 5 7 1 3 5 7
Mechanical interlock
NO.3 terminal as the
feedback port of the access
Fu2
control,and the NO.4 terminal
The bolts for installing
the safety guard boards as the port of the external Fu1
A2 B2 C2 N2 A1 B1 C1 N1
indicator.
Back 2 road Front I road 102 103 104 105 101 106 302 305 304 303 405 404 403 402
bar out-put bar out-put N F
FU1/FU2 is 2A fuse Upper power power
NO.1 control 201
power terminal
end 202
SB1
connection modes
A 03 04 A
Suyang Quality, Rock Solid
SYK1/K2 Series Automatic Transfer Switch SYK1/K2 Series Automatic Transfer Switch
SYK Series connection modes
SYK1/SYK2 Automatic-type connection mode Automatic-type+Manual-type(Remote-type) connection modes (two main supply)
Automatic Manual
Main power Standby power Main power Standby power
Note: Note:
Hl1 and HL2 are common power supply and standby power indicating instructions respectively SA is the option button for choosing Automatic-type or Manual-type function
HD1 and HD2 are common power supply and standby power input instructions respectively SB1 is the manual power input button (passive contact) for main power supply
FU1 and FU2 are 2A fuses SB2 is the manual input button for standby power supply (passive contact)
101-106, 201-206 and 301-306 are SYK1 connection terminals SB3 is the force to "O" position button (passive contact) (need self lock)
SYK1/SYK2 Automatic-type + Force to O position type (Both powers are break off) connection mode
Start signal for the generator connection mode
Main power Standby power
The generator interface has been supplied (301-306 terminals with the signal of 'UGE1' ) ,
the wiring diagram is as follows:
301 306
Note:
SB1 is the manual power input button (passive contact) for main power supply
SB2 is the manual input button for standby power supply (passive contact)
SB3 is the force to "O" position button (passive contact) (need self lock)
A 05 06 A
Suyang Quality, Rock Solid
SYKZ-F Automatic Transfer SYKZ-F Automatic transfer switch intelligent controller use the microprocessor as its core, could accurately detect
the two phase three phases voltage. It could make accurate judgement on the abnormal voltage(decompression, over-
voltage, under-voltage , phase loss), then control the ATS after a certain time delay. When there is something wrong with
Switch Intelligent Controller one of the power it could send a signal to start the generator.
◆ Input power
AC power supply of the controller: Ac230v ± 20%(Hz) (I, II. A, N phase voltage).
Detection voltage: Rated 380V (Hz) Three-phase four-wire, other detection voltage levels, please consult before order.
◆ Power supply anomaly amplitude setting range
Over-pressure threshold: 264V (PC only).
Under-voltage threshold: 172V (set only via PC).
◆ Change-over Time
Closing time: 5 seconds, if the switching signal is detected in the process of effective , then immediately disconnect.
Break time: 3 seconds, if the switch in the process of detection of the signal is invalid, then immediately disconnect.
Normal power delay: (0-60) seconds (adjustable through the Controller panel potentiometer)
Abnormal power supply delay: (0-60) seconds, factory value: 5 Seconds (can be adjusted through the Controller panel
potentiometer)
Generator Set power-on delay: I road anomaly after confirmation, the delay start (0-60) seconds (only through the
controller panel on the potentiometer adjustment).
Generator Set Downtime delay: I road after the normal confirmation, delay start (0-60) seconds (only through the
controller panel on Potentiometer adjustment or PC adjustment).
◆I/ II Road closing State detect (can be programmed through the Controller panel button) factory value: Detect I/II Circuit
closing state input, that is the controller must access the switch state signal.
◆ Power consumption
The power consumption of the voltage circuit at the rated voltage is less than 2VA
◆ Environmental conditions
Temperature: (-30~+70)℃ Humidity (20~95)%
◆ Net Weight: 0. 47kg
A 07 08 A
Suyang Quality, Rock Solid
R1
S1
T1
N1
10A
N1 C1 B1 A1 L O N O C O M I II GND S1 S 2 A2 B2 C2 N2
power supply
ATS working
closing control
I road
closing control
II road
Grounding
closing status
I road
closing status
II road
119mm
130mm
111mm
60mm 6mm
129mm
138mm
A 09 10 A
Suyang Quality, Rock Solid
Note: If required, the handle could be removed, the totally high is 110mm.
II. Overview
This product is a new generation of the use of the instantaneous of the PC level ATS , compared with the
traditional motor-driven modem , it has the advantage of simple structure, fast conversion speed (less than 80ms),
and use the main contact system of the single pole double throw(V) structure.which could not lead to the two power
supply connected at the same time ,even if in the emergency situation.
SY P
Pole
Type(T/N/N2)
Rated current (A)
Design No.
Automatic transfer switch
Yangzhou Suyang Electric CO., Ltd
SYD1 series electromagnetic automatic transfer switch is suitable for rated voltage 690V, rated frequency Type S
50/60HZ, rated voltage 440V and below, rated current of 16A-4000A, mainly used between in the two powers in the Rated working current(A)
emergency case of the power supply system , in order to make sure the main load of the important places' could keep
continuous and reliable power supply. It would be widely used for providing uninterrupted and normal power supply for
high-rise buildings, hospitals, markets,banks, fire-fighting, chemical industries,metallurgy, etc..
V.Working Condition
A 11 12 A
Suyang Quality, Rock Solid
Type S
Rated working current(A)
SYQ1 Series
Automatic Transfer Switch
A 13 14 A
Suyang Quality, Rock Solid
SYQ1 Series Automatic Transfer Switch SYQ1 Series Automatic Transfer Switch
I.Introduction
VI. Outline and Installation Dimension
SYQ1 Series Automatic Transfer Switch (ATS) is suitable for double power supply system (AC 50/60Hz, rated
voltage is 440V, rated current is 6A-1250A). The ATS can autotransfer between common power supply and standby
power supply to ensure the continuity and reliablity of power supply without manual operation.
W
The body of ATS consists of forward and reversing motor, circuit breaker, mechanical interlock and controller.
W1
The product are used in some important places where not allow blackout: Ⅰ power systems, high-rise buildings,
housing estates, military installations, hospitals, airports, communications, fires, etc. The ATS meet IEC60947-6-1、
GB/T14048.11 standards.
SYQ1 Series Automatic Transfer Switch
II. Overview
L1
L
SYQ1 Series Automatic Transfer Switch (ATS) is suitable for a three-phase four-wire double power supply
system (AC 50/60Hz, rated voltage is 440V, rated current is 6A-1250A), it can connect one or several load circuits common
closing
standby
closing
from one power supply to another automatically, to ensure the nomal power supply of the load circuit. This Product
are used in industrial sites、 commercial spaces、 high-rise buildings、 residential buildings and other important
places. The ATS meet IEC60947-6-1、GB/T14048.11 standards.
SYQ1-63 (basic type) terminal wiring principle SYQ1-63 (fire、power type) terminal wiring principle
III.Types and Classification Indicator Light is 220V
Terminal:
Indicator Light is 220V
Terminal:
1:Common Power Indicated Output 1:Common Closing Indicated Output
No External Power Supply 2:Common Closing Indicated Output No External Power Supply 2:Standby Closing Indicated Output
Signal Output
Generator
3:Common Zero Line Output 3:Zero Line Output
Power
Common
Closing
Common
Power
Standby
Closing
Standby
Closing
Common
Closing
Standby
4:Standby Power Indicated Output 4:Common Signaling Point of Fire Power
5:Standby Closing Indicated Output 5:Fire Double Portion (DC24V) Signal Input
Pole 6:Standby Zero Line Output 6:Generator Signal Output
Plug common zero line into terminal 3 Notes: If it is a three-pole ATS, please
Rated Current for Circuit Breaker 1 2 3 4 5 6 Plug standby zero line into terminal 6 1 2 3 4 5 6 plug standby zero line into terminal 3
Design No.
CB-level ATS
Dimension
Yangzhou Suyang Electric CO., Ltd Specification W W1 L L1 H
SYQ1-63/2P 150 135 132 120 122
SYQ1-63/3P 185 165 132 120 122
IV. Service Conditions
SYQ1-63/4P 220 200 132 120 122
◆Ambient Air Temperature ◇Maximum Temperature: +40℃
◇Minimum Temperature: -5℃ W H
◇Average Temperature in 24h: ≤+35℃ W1 Note: If the ATS is two-pole,
please connect zero line with 1
◆Altitude: Installation altitude ≤2000m
1 2 3 4 5 6
◆Atmospheric Conditions: when the maximum temperature is +40℃, the relative humidity is less
than 50%, a high relative humidity is allowed when the temperature is low, for example, when the Normal Standby
Source SYQ1 Series Automatic Transfer Switch Source
temperature is 20℃ , the humidity is 90%. Users should take special measures for condensation
COM
power output
instruction
normally on
caused by temperature changes.
L1
L
◆Pollution Level: 3
◆Electrical Level: CB
Load Side Load Side
instruction
normally on
instruction
standby on
COM
power output
3P (general lighting) SYQ1-225/3P 376.5 356 189 162 132
SYQ1 Tripping Current Range: SYQ1-225/4P
5In-10In 411.5 391 189 162 132
SYQ1-400/3P 460 420 350 302 220
4P D-type Power Protection: Note: If the ATS is three-pole, please connect
10In-14In SYQ1-400/4P 510 470 350 330 220 common zero line with 1, standby zero line with 3
SYQ1-630/3P 530 490 350 330 245 SYQ1-400~630
Notes: The input voltage is 230V, only connect to A phase (detection phase) of miniature circuit breaker (MCB).
SYQ1-630/4P 590 550 350 330 245
A 15 16 A
Suyang Quality, Rock Solid
SYS1 Series SYS1 Series Manual transfer switch is suitable for AC:50HZ,rated voltage 660V below,DC: rated voltage
440V, used in the industrial power supply system for the two low-voltage circuit switching or two of load equipment
conversion or isolation.
The switch has a glass fiber reinforced unsaturated polyester resin shell, Spring Energy storage acceleration
mechanism, fast realization connecting and breaking, parallel double breakpoint two separate contact head, use
the chip spring to ensure the contact pressure, automatically determine the limit position of the on-off, has obvious
on-off mark indicating the location of the broken.
IV.Technical Parameters
Conventional
thermal current
Rated isolation
voltage (Ui)
Rated impulse
withstand voltage
(Uimp)
Rated working
voltage (Ue)
Rated working
current(Ie)
Rated making
capacity
Rated breaking
capacity
Rated limited
breaking current
Rated short-time
withstand current
A 17 18 A
Suyang Quality, Rock Solid
SYF1 Series
Load Isolating Switch
Mounting
Appearance dimension Wiring dimension Handle
dimensions
Specification
A 19 20 B
Suyang Quality, Rock Solid
SYF1-125~630A
II.Types and Classification Inside-cabinet operation
Installing specialized
SYF1 baseboard
Cabinet-after operation,
marked only needed
Load Isolation switch code
Board-after wiring , the front do not note Below 630A Installing
C side-operation specialized baseboard
Load isolating switch
Auxiliary contact code(refer to diagram), Baseboard dimension
Z conversion load Specification
marked only
isolating switch(up-down)
Z2 conversion load SYF1
isolating switch(left-right) Directly observe auxiliary contact window , SYF1-125~630A/JK SYF1
marked only needed. Outside-cabinet operation SYF1
Diagram
Outside-cabinet operation ,
the inside do not mark
One often-open
one often-closed Appearance and mounting dimensions
Pole: 3 pole,4pole Specification
Two often-open (3 Poles + can break the neutral pole)
two often-closed
SYF1
Example: Rated current 630A, neutral Rated current
pole, outside-cabinet operation, the SYF1
type will be HGLZ-630/4J.
SYF1
SYF1
Using modular design, suitable for connecting with the split power circuit or electrical isolation. The 1000A and
above is only could be used for electrical isolation; SYF1
The use of spring energy storage, instantaneous release of the acceleration of the closing mechanism with the SYF1
simultaneous and disconnected parallel double breakpoint contact structure,which has greatly improving the product's
SYF1
electrical performance and mechanical properties;
The use of glass fiber reinforced unsaturated polyester mold plastic and manual handle, to realize high dielectric SYF1
properties, protection and reliable operating safety;
SYF1
With 3 poles, 4 poles (3 Poles + can break the neutral pole);
The front is provided with a marking window ,indicating the On-off state of the contact, which can provide a rear SYF1
observation window to directly observe the On-off state of the contact ,to ensure the reliability and safety of the switch SYF1
operation;
SYF1
Handle can be directly installed on the switch operation ( the cabinet operation), but also through the addition of
long shaft in the power distribution cabinet door operation (the operation outside the counter), to provide convenient SYF1
operation;
SYF1
If needed ,we Can provide often open and closed auxiliary contacts , install special floor panel and front panel
connection modes , to meet the diverse needs of the customers; SYF1
In the breaking position "0", can be used two or three locks to lock the handle to prevent misoperation.
B 21 22 B
Suyang Quality, Rock Solid
Inside-cabinet
operation Outside-cabinet
operation
SYF1C-125~630A/K
Inside-cabinet operation
Installing specialized
baseboard
SYF1 SYF1
SYF1 SYF1
SYF1 SYF1
SYF1 SYF1
SYF1 SYF1
SYF1 SYF1
SYF1
SYF1
Specification
SYF1
SYF1
SYF1
SYF1
SYF1
SYF1 SYF1
SYF1 SYF1
SYF1 SYF1
SYF1
SYF1
SYF1
B 23 24 B
Suyang Quality, Rock Solid
SYR1 Series
Outside-cabinet handle
Switch-Disconnector-Fuse
SYF1C-1000、1250、1600A
Above 1000A
SYF1C-2000、2500、3200A Installing specialized baseboard
Specification
SYF1
SYF1
SYF1
SYF1
SYF1
SYF1
Specification
SYF1
SYF1
SYF1
SYF1
SYF1
SYF1
B 25 26 C
Suyang Quality, Rock Solid
SY R1 A / - C J B
ⅠModular(160~400A-1250A)
Style
ⅡMonolithic(400~630A)
rear connection, front connection are not marked Note: Unnecessary functions are
Auxiliary contact not marked.
Operate outside the cabinet, standard extension shaft 330mm F- normally open or normally
The special length is indicated after J, the operation inside closed auxiliary contacts,
the cabinet is not marked.
S- normally open + normally
Side operation, front operation are not marked.
closed S type auxiliary contacts,
Rated current of fuse (A) U-U auxiliary contacts.
Pole number 2p, 3p, 4p
(3p + on-off neutral pole) Selection example: rated current 1 normally open or normally
160A, 3 poles, Side-inside closed auxiliary contacts
Rated current
cabinet operation.
Code
2 normally open or normally
Yangzhou Suyang Electric Co,. Ltd. closed auxiliary contacts
Fuse function 600V, AC (V) (W) 7.5 7.5 9.6 18.3 26 40.3 90
Rated insulator voltage Ui (V) (Installation type IV) 690 690 690 690 690 690
Rated limited short-circuit current 100 100 100 100 100 100 100
Rated connection capacity 320 630 1600 2500 400 6300 12500
Rated breaking capacity 256 504 1280 2000 3200 5000 10000
Combination neutral wire connection
Mechanical life(Cycle operation times) 1700 1700 1400 800 800 800 500
Electrical life(Cycle operation times) 300 300 200 200 200 200 100
Operating torque, front operation 15 10 12 15 42 42
3P 1 1.8 3.2 4.8 16 28
Weight (Kg)
4P 1.3 2.3 4.5 6.1 19 33
C 27 28 C
Suyang Quality, Rock Solid
Overall and Installation Dimensions of SYR1-63A~400A Overall and Installation Dimensions of SYR1-63A~400A
A
H1
T
H1
I
U
B
K
B
U
B
K
7 0°
126
SYR1C-63A-3 SYR1-250A-3
I
φ31 4-φ4.5
H1
H1
9 0°
φX I
C E
50
R φX
H R P
A J
50
H 门孔
SYR1-63A~250A side operation
SYR1-63A~400A front operation outside cabinet
C A SYR1C-63A-4 SYR1-250A-4
E
Y P M 21
T L I
H1
90° Y
T
F
U
B
φ31 4-φ4.5
K
B
U
B
F
I
50
H1
J φX SYR1-160A-3 SYR1-400A-3 50
R P 门孔
H
P 70
126.5
SYR1-63A~400A front operation
SYR1-63A~400A side operation outside cabinet
Extension without linkage
Specifications Fuse size Overall dimensions and installation dimensions Specifications Fuse size Overall dimensions and installation dimensions
SYR1-63~400A A B C E F H U I J K L M P R T φX Y SYR1-63~400A A B D E F H U I J K L M P R T φX Y
SYR1-160A-4
63A/3 00C 152 118 192 117 114 95 159 145 5 64 32 63A/3 00C 133 118 20~30 117 114 116.5 95 159 145 5 36 32
63A/4 00C 184 118 192 117 114 95 159 145 5 64 32 63A/4 00C 164 118 20~30 117 114 116.5 95 159 145 5 36 32
160/3 00 164 162 192 126 118 108 100 141 189 140 5.4 68 36 20 2.5 8.5 19.5 160/3 00 150 162 28~30 126 118 108 100 141 189 140 5.4 38 36 20 2.5 8.5 19.5
160/4 00 200 162 192 126 118 144 100 141 189 140 5.4 68 36 20 2.5 8.5 19.5 160/4 00 186 162 28~30 126 118 144 100 141 189 140 5.4 38 36 20 2.5 8.5 19.5
250/3 1 236 195 201 146 162 180 140 185 251 165 6.2 92 60 32 2.5 11 19.5 250/3 1 253 195 28~30 146 162 180 140 185 251 165 6.2 54 60 32 2.5 11 19.5
250/4 1 296 195 201 146 162 240 140 185 251 165 6.2 115 60 32 2.5 11 19.5 250/4 1 313 195 28~30 146 162 240 140 185 251 165 6.2 81 60 32 2.5 11 19.5
400/3 2 278 205 201 149 170 192 150 200 260 175 7 121 66 50 3 11 20 400/3 2 271 205 28~30 149 170 192 150 200 260 175 7 86 66 50 3 11 20
400/4 2 344 205 201 149 170 258 150 200 260 175 7 121 66 50 3 11 20 400/4 2 337 205 28~30 149 170 250 150 200 260 175 7 89 66 50 3 11 20
C 29 30 C
Suyang Quality, Rock Solid
Overall and Installation Dimensions of SYR1-630A Overall and Installation Dimensions of SYR1-1250A
14.5 11.5
68
13
10.5
20
25
O OFF 40
77
330
min330
90°
68
46
28 68
I ON
120 120 min15
442(3P)
Direct padlock handle 562(4P)
Inside cabinet: 330 Extra plus 260 outside the cabinet fix 362 (3P)
fix 482 (4P)
289
A Y
A1 Terminal shield
J2 J J1 11
79.5 34
H
T
R φ13
S
22
fix 250
300
260
SYR1-1250A-3
B1
90
SYR1-630A-3
K
7
U
B
190
° 7
k
55
355
oc
dl
pa
φL E 59
120 120
C
P P P M N
295
50 Padlock position
SYR1-630A-4
max.Φ0.31 in/Φ8mm
min.Φ0.19 in/Φ5mm
50
门孔 Φ4.5
Φ30
96
50
Specifications Fuse size Overall dimensions and installation dimensions 50
90°
SYR1-400-630A A A1 B B1 C E H2 J J2 J1 K M N P R S T U φL Y 0
630A/3 3 470 345 300 150 348 268 85 250 76 250 38.5 162 80 50 50 7 260 7 74
Padlock position
630A/4 3 550 425 300 150 348 268 85 250 100 76 250 38.5 162 80 50 50 7 260 7 74
C 31 32 C
Suyang Quality, Rock Solid
SYCPS generation of major products to fill the gap in our country in 90s.
Standards:“ Low voltage switch equipment and control equipment sixth parts: multi-function electric appliance
Control and Protection Switch second section: control and protect switch electric appliance”“Low voltage switch equipment and control equipment
multi-function electrical appliance (equipment) second parts: control and protection switch electric appliance
(equipment) “(Equate adoption)
Electrical symbols
III. Application
SYCPS products using single a product structure modularization, it is the integration of traditional circuit breaker
(fuse), contactor, overload (or over-current, phase failure) protection relays, starter, isolator and other main functions,
it has remote automatic control and local direct manual control function, with panel indicator and electrical signal alarm
function, with overvoltage and undervoltage protection function, with phase failure protection function, with the
characteristics of time-current protection coordination (anti time limit, time limit and instantaneous three phase
protection characteristics). Matching function modules or accessories according to the requirements , to control and
protect load and distribution loadall of all kinds of motor.
SYCPS is mainly used in power system which is AC 50Hz (60Hz), rated voltage to 690V, rated current from 1A
to 125A, and it can connect, load and break the current under normal conditions (including prescribed overload
conditions), and it can be switched on, carrying and breaking the current under prescribed abnormal conditions (such
as short circuit).
Low voltage distribution system, motor control and protection system for general industry, agriculture, commerce,
civil construction, such as: single machine control and protection in factory or workshop (equivalent to power terminal);
motor control center (MCC), especially the intelligent electric control system or MCC with high breaking capacity (the
distribution control and protection system requiring Icu50kA or cs35kA); integrated distribution system; Electrical
control and protection systems for lighting, power conversion, fans, air conditioning, fire fighting, water supply, etc. Of
modern buildings.
V. Operating conditions
Elevation:≤2000m Installation category: III II
Ambient temperature:-25℃~+40℃ Fluctuation range of control power supply voltage: 85%us-110%us
(you must take special project at -40℃~+80℃) Pollution degree:3
Relative humidity of air:90%
D 33 34 D
Suyang Quality, Rock Solid
SYCPS Control and Protection Switch SYCPS Control and Protection Switch
VI. Product features VIII.Types and Classification
Compared with the low voltage power distribution and control system composed of discrete components
SY CPS
★Easy to design and install, , simple operation, convenient application: SYCPS switch integrates circuit breakers, contactors,
thermal relays and other control and protection functions on a single structure of the appliance, there is no need to consider the Slection Function Code: F-fire, G-isolation, L-leakage, T-communication
characteristic matching among the components in the user selection. There's no need to reduce capacity under the AC44 usage
category, you can choose the correct SYCPS switch products only based on either the load power or the rated operating current. Control supply voltage:M-AC220V、Q-AC380V
SYCPS switch can replace the low-voltage distribution and control system of a variety of electrical appliances, reducing the workload
of the design and installation personnel. Accessory code: 02--2 normal open and 1 normal closed +1 short circuit and
1 overload、06-3 normal open and 2 normal closed + 1 short circuit and 1 overload
★Small size, high reliability and easy maintenance: SYCPS switch has changed traditional configuration of multiple component
series combination, make the installation space reduced more than 50%, the system reliability is greatly improved; After breaking the
fault line, if the fault is eliminated, the SYCPS switch can be safely put into continuous operation without maintenance, and the Intelligent release code (Express by class code + rated current)
maintenance is simple.
★Complete function, complete protection: SYCPS switch circuit, blocking the road, overload, phase, phase imbalance, residual Poles: in two digits, the former represents the poles, and the latter indicates
the number of protective poles.
current (leakage), overvoltage, voltage loss, undervoltage protection function can also be ground fault, personal electric shock hazard
Breaking capacity: C-economical type(35KA), Y-standard type(50KA),
provide indirect protection. At the same time, a remote communication function. The user can choose according to need flexible. Ii H-high breaking type(80KA)
can improve the function and reliability of information system.
Compared with molded case circuit breakers Main release current: 6.3~125A
★ High breaking capacity: SYCPS switch has a strong short-circuit breaking capacity (Ics is 50KA, Icu is 80KA), the total
short-circuit breaking time is less than 10ms, the current limiting coefficient is less than 0.4, and the dynamic and thermal impact of Product Combination: Basic type - no code、N-reversible control、
J--voltage reducing starter、S-ATS、D-two speed motors、
the short circuit current on the system can be reduced, and it can achieve zero arc. Z-main and auxiliary motor controller
★ Protection characteristics is perfect, reasonable and reliable: implementation of protection measures, the use of digital
measuring and processing technology action is accurate, reliable, continuous tuning values can be set within a predetermined range. Current level of shell frame(45、125)
Functions: voltage detection (V products), current detection, fault warning, fault type recognition and memory functions.current
detection, fault warning, fault type identification and storage memory. Control and protection switch apparatus (Multi-function electric appliance)
★Long service life, high reliability, remote control: SYCPS switch increase the breaking speed and reduce the breaking time by
pulse degaussing technology, and abandon the traditional mechanical tripping device in circuit breaker. Fewer parts, high reliability, Yangzhou Suyang Electric Co., Ltd.
and can realize remote control.
Compared with contactor
SYCPS switch operation electromagnet adopts intelligent control, the coil is powered by a DC pulse, the intelligent controller
can adaptively adjust the width of the pulse exciting voltage according to the supply voltage, to ensure the optimum matching between IX.Working principle
suction characteristics and reaction characteristicsso, which greatly reduces the collision and contact bounce closure process,
contact wear is small, not welding, long life, in the use of AC43 category can reach more than 1 million times. The SYCPS switch consists of two parts, the main body and the intelligent controller, the main method of electromagnetic
system is operating mechanism, driving the contacts movement to achieve on the main circuit or breaking. Using the intelligent
★Connect, breaking capacity: SYCPS switch can be switched on, carrying, breaking current 16le, it is suitable for work in the
control and power electronic technology to control the motion of electromagnet characteristics; Using pulse demagnetization
heavy load situation, in the use of AC44 class without derating. Especially A type products of SYCPS, is suitable for heavy-duty lifting
technology to improve the speed of opening of electromagnet.
device and frequent operation.
The intelligent controller detects the main circuit current and the coil supply voltageI, according to the main circuit current fault
★Low energy consumption, no noise: when the electromagnet is pulled in, it uses the DC low voltage power supply to keep the
diagnosis, calculate the winding temperature rise, once the fault occurs, then issue tripping instructions to control the electromagnet
electromagnet attracting, without noise and low energy consumption.
breaking. In normal working conditions, the display shows the current value of each phase and the temperature rise of the winding in
★ Non burning coil: when the coil control voltage fluctuations and coil heating, SYCPS switch automatically according to the
turn, to facilitate the user to keep abreast of the operation of the switch. If the user open the alarm function, when the protective circuit
control voltage and coil resistance adjusting pulse width of excitation voltage, electromagnet, changed into DC low voltage power
or equipment overload temperature rise to the limit of action, the switch issued warning sound, prompting operators to take
supply. Low coil power consumption, even if the long-term work, the coil heat is low, do not burn the coil.
appropriate measures to prevent the motor continues to overload. If the overload is not eliminated in time, the switch will break the
fault line when the temperature rise reaches the limit. If the warning function switch is not opened, when the fault reaches the safety
VII.Product function of the equipment, the SYCPS switch will trip and make a sound alarm.
★ Circuit breaker function: short circuit protection function, it can be divided into short-circuit current breaking the Body panel diagram
corresponding level specified in 10ms, the limiting factor is less than 0.4. If the rated service short-circuit breaking capacity Ics of Automatic control position: CPS coil control contact in
SYKB0-100 switch is 35KA, rated ultimate short-circuit breaking capacity Icu is 50KA. At the same time, V products has fuctions with Tripping position: In the connected circuit, such as overload, the closed position, in this state, through the coil
overvoltage, undervoltage, loss pressure protection. overcurrent, short circuit, open phase, and remote shunt tripping, control circuit on-off can be remote automatic control.
the product corresponding function module take action, to make the
★Contactor function: 50Hz or 60Hz AC, rated insulation voltage is 660V. Under AC43 and AC44 categories, rated voltage is main contacts and coil control contacts are in the open position.
380V, rated current is 1A~100A, frequent operation, motor starting control, stop or reverse, and can realize remote control.
★Thermal relay and overcurrent relay function: with perfect, reasonable, continuous three section protection function and motor
starting time limit protection, overload protection mode uses the most advanced double time constant index, and the protected object
allows the overload characteristic matching, its action is accurate and reliable. Disconnect position: coil control contact is in the
disconnection position, and the CPS main contact
★ Starter function: can replace contactor and thermal relay combination starter, control motor start. Phase missing, three- remains in the disconnected position.
phase unbalanced protection function (NQ, WQ products) leakage protection function (L products).
★Counter function: During operation, the cumulative operation times of the switch are recorded and displayed on the display,
users can decide whether or not to replace the new switch according to the recorded data, calculate shift output or the remaining life Re-trip position: When the operation knob is
of the switch. rotated to the position, the tripping CPS can be
normally reset and re-trip.
★Detection and display function: alarm function can be turned on or off according to the user's needs, when the equipment is
overloaded and the temperature rise reaches the warning limit, warning voice, to facilitate timely troubleshooting.
★ Fault diagnosis function: during operation, the current value of three-phase winding is detected in real time, and the
temperature rise of three-phase winding is calculated, the detection and processing results are shown on the display in turn.
★Warning function: when the system fails, the switch can automatically identify, store and record the fault type and display it,
which is easy for users to troubleshoot.
D 35 36 D
Suyang Quality, Rock Solid
SYCPS Control and Protection Switch SYCPS Control and Protection Switch
XI. Parameters of intelligent release
Main circuit contactor (including contact system, short circuit release)
The main circuit contactor of SYCPS control and protection switch consists of moving and static bridge type double break contact, Rated current Rated operating current of Rated operating current Control power
Shell current of main body overload electronic release adjustment range of range of 380V Usage Rated Rated
grid plate arc extinguishing chamber and current limiting fast short-circuit release mechanism. Each pole is independent of each other. overload electronic release class voltage(V) power(Hz)
(Ith A) (Im A) (Ie A) (kW)
The main circuit contactor with limited flow type quick short-circuit tripping device, and extinguishing system of high breaking capacity, (Ie A)
high current limiting characteristics (limiting coefficient is less than 0.2) of the backup protection, tripping setting current value is:
16In+20%, the numerical value is not adjustable, and is only related to shell grade. When the load is short circuited, the release opens the
main contactor quickly(2~3ms), at the same time, it drives the operating mechanism to cut off the control coil circuit, then all the main
circuit is disconnected.
Frame
CPS-45 CPS-125
Project
、125
SYCPS switch has the characteristics of overload, reverse time, long time delay, short circuit transient, short
circuit and short delay, three phase protection, and motor starting timing limit. And functions of residual current,
delay type protection, phase or three-phase unbalanced protection, overvoltage protection, undervoltage
protection and reclosing.
D 37 38 D
Suyang Quality, Rock Solid
SYCPS Control and Protection Switch SYCPS Control and Protection Switch
XIII、Installation and appearance
Protection characteristic parameter
Movement time(min)
Phase failure or three-phase
unbalance protection Current setting range (multiple)
Action time(S)
Short circuit short time
delay protection
Voltage setting range (multiple)
Action time(S)
Undervoltage protection
Voltage setting range (multiple)
Protection Limit
features non-actuating Residual current
(optional) time
Maximum movement time
Limit non-actuating time
Maximum movement time
Limit non-actuating time
Maximum movement time
Limit non-actuating time
D 39 40 D
Suyang Quality, Rock Solid
SYCPS Control and Protection Switch SYCPS Control and Protection Switch
XIV. SYCPS-F fire-type control and protection switch XVI. SYCPS-G isolated control panel
Purpose
SYCPS-Ffire-type control and protection switch (60Hz) is mainly used in fire protection system which is AC 50Hz, Tripping position: In the connected circuit, Automatic control position: CPS coil control
rated voltage to 690V, rated current from 0.16A to 125A. It is capable of being switched on, carrying normal such as overload, overcurrent, short circuit, contact in the closed position, in this state,
open phase, and remote shunt tripping, the through the coil control circuit on-off can be
conditions, including prescribed overload, current under overcurrent conditions, it can realize only alarm, no product corresponding function module take remote automatic control.
action, to make the main contacts and coil
tripping, and can connect, load and break the current (such as short circuit current) under abnormal conditions, control contacts are in the open position.
and realize the alarm and trip, and the main parameters of the main circuit and the accessory module are the same
as the basic type of the SYCPS. Disconnect position: coil control
contact is in the disconnection
Product type position, and the CPS main contact
remains in the disconnected position.
Take SYCPS-F fire control and protection switch circuit as main body, derived the following series of
products: Re-trip position: When the operation
knob is rotated to the position, the Isolation position: turn the CPS
SYCPS-FG Isolated fire fighting type tripping CPS can be normally reset knob to OFF, turn the isolating
and re-trip. latch in the knob (available
SYCPSD-F Fire fighting type double speed motor controller padlock), and the main internal
circuit is in the isolated state of
SYCPSD3-F Fire fighting type three speed motor controller disconnection.
SYCPSJ-F, SYCPSJ2-F, SYCPSZ-F, SYCPSR-F Fire fighting pressure reducing starter
SYCPSN-F Reversible control and protection switch apparatus
SYBK1-F Fire protection control box
Special Note
In the line failure, the fire-type product alarm, you must turn the red knob to the re-trip position, you can lift the
alarm signal, when you continue to use, you should turn the knob to the connecting position. XVII.Basic electrical control diagram
XV.SYCPS-G isolated control and protection switch Secondary Power Local manual Auxiliary signal Alarm signal Secondary Power Local manual Auxiliary signal Alarm signal
power protection control operation stop short circuit fault power protection control operation stop short circuit fault
Purpose
SYCPS-G isolated products is applicable to the power distribution circuit and electric circuit, the main
circuit can meet the isolation requirements, also meet the requirement of isolation of control circuit, the position
of the position indicator (operation knob) can be clearly displayed.
Parameters of the main circuit and the accessory module are the same as those of the SYCPS.
When the handle is in the isolated position, the isolating product has a locking device and can be locked.
The padlock is supplied by the customer.
SY CPS 45 C 33 B40 06 M F G
Operating voltage:220V
Accessories code:
06-3 normally open 2 normally closed +1 short circuit 1 overload
40A Digital tube intelligent controller rated operating current
Poles and protection:3p with 3p protection
D 41 42 D
Suyang Quality, Rock Solid
SYCPS Control and Protection Switch SYCPS Control and Protection Switch
XVIII. SYCPS-N communication type control and protection switch XIX.SYCPS-L leakage-type control and protection switch
When leakage current is 100mA, SYCPS action time is less than 0.2s. The leakage current value can be set
2. Network communication
according to user's needs according to the setting value serial number, corresponding leakage current value of set
value serial number see below.
3. Operation instruction
RS485 When SYCPS leakage-type control and protection switch is operating, three-phase current and leakage
1SYCPS 2SYCPS 3SYCPS 4SYCPS 5SYCPS 6SYCPS NSYCPS current are displayed circularly, which is convenient for users to check the leakage of load.
This module is optional, and the fire protection type can be selected.
RS485 communication interface with open field bus, comply with the Modbus agreement. 4. Main parameters and application instructions
Main technical parameters of SYCPS leakage type control and protection switch are the same as those of
SYCPS-L
D 43 44 D
Suyang Quality, Rock Solid
III.Characteristic
1.Breaking capacity (see Table 1) Table 1
Rated current Rated ultimate short-circuit breaking capacity Tripping current range of
Poles Voltage (V)
(A) Breaking current instantaneous release
3In~5In(Type B)
5In~10In(Type C)
10In~20In(Type D)
Tripping
E 45 46 E
Suyang Quality, Rock Solid
SYDZ47-125 is suitable for short circuit protection and overload protection, it is used in distribution system
for lighting distribution systems or motors. It has compact appearance, light weight, excellent performance, reliable
high breaking capacity, rapid release, rail installation, shell and components are made of high impact resistance
SYDZ47LE Series
and flame retardant plastics and long service life, it is mainly used for overload and short circuit protection for
power supply which is AC 50Hz, rated voltage to 230/400V, rated current to 125A, at the same time, electrical Leakage Circuit Breaker
equipment and lighting circuits can be broken down frequently under normal conditions.
This product complies with GB 14048.2 standard.
Table 1
Serial Rated current Starting state Test current Regulation time Remarks
number of release Expected results
Overall dimensions
Thermal / electromagnetic tripping characteristic
2.Spot
tripping 2.Spot
tripping
C D
E 47 48 E
Suyang Quality, Rock Solid
Leakage circuit breaker is suitable for leakage protection for power supply shich is AC 50Hz, rated voltage is SYDZ47LE-125 residual current circuit breaker is suitable for AC 50Hz, rated voltage of single pole two line,
230V/400V, rated current to 63A. When someone gets an electric shock or the circuit leakage current exceeds the two 230V, 3P, four line, quadrupole 400V, rated current from 63A to 125A in the circuit, when the electric power
specified value, the leakage circuit breaker can automatically cut off the power supply in 0.1s to ensure personal grid or leakage current exceeds the set value, residual current circuit breaker can cut off the power supply fault
safety and prevent the accident caused by the leakage current of the equipment. quickly in a very short period of time to protect the personal safety of the electric equipment, leakage circuit breaker
Leakage circuit breaker with overload and short circuit protection function, it is used to protect the circuit from with overload and short circuit protection function, it is used to protect the circuit from overload and short circuit, but
overload and short circuit, but also in normal circumstances, line is not installed for frequent use. also in normal circumstances, line is not installed for frequent use.
This product complies with GB 16917.1 standard. This product complies with GB 14048.2, IEC 60947-2 standard.
Residual current interrupting time of leakage circuit breaker is shown in table 1: table 1
Maximum (residual current) breaking time IV.Main parameters and technical performance
Category
4.1 Classification: 4.2.8 The breaking time of the residual current (see Table 1);
Indirect contact Any value 4.1.1 Poles:1P+N、2P、3P、3P+N、4P; 4.2.9 Mechanical and electrical life:
Direct grounding Any value 4.1.2 Short-circuit tripping performance:(8~12)In Electrical life:1500 times,cosΦ=0.85~0.9;
No tripping I△m(A):2000;
cold state
All values
Table 1
III.Installation dimension
Overcurrent protection characteristics (see Table 2)
Table 2
Poles Specified time
Width
Starting state Expected Remarks
Test current
In=63A In>63A results
E 49 50 E
Suyang Quality, Rock Solid
SYDZ47LE-125 Series
Structure and working principle V.Other
5.1 Structure and working principle
5.1.1 Structure
The residual current operated circuit breaker consists of a DZ47LE-125
moulded case circuit breaker and a residual current release device. DZ47LE-
SYCM1 Series
Moulded Case Circuit Breaker
125 is mainly composed of insulation shell, operating mechanism, static and
dynamic contact, delay and instantaneous release, arc extinguishing chamber.
The residual current release is mainly composed of zero sequence transformer,
electronic discrimination control circuit, release push rod, test button and so on.
The moulded case circuit breaker is connected with the residual current
release device by a push rod.
5.1.2 Working principle
When the residual current operated circuit breaker handle is pulled to the ON
position, the moving contact is driven by the mechanical mechanism to the
static contact and is in reliable contact with the static contact , the circuit is
connected. When the circuit is overload, the overload current causes the
thermal bimetallic element to bend and push the lever so that the mechanical
locking mechanism is reset, the moving contact rapidly moves away from the
static contact to break circuit. When the circuit is overload, the short circuit
current causes the instantaneous release action, and the iron core push rod
enables the locking mechanical reset to realize the breaking function. When
residual current or electric shock occurs on the circuit, signals produced by the
zero sequence transformer Trigger thyristor turn-on, the residual current
release core is operated, push rod drives the circuit breaker to trip, and the
residual current action breaker cuts off the power supply in a very short time to
realize the residual current protection function.
5.2 Connection
Suitable for (10~50) 2mm wire connections, tightening torque of the terminal shall not be greater than 3.5N.m. Before installation, users should select
appropriate wire to connect the residual current action circuit breaker to the circuit. The cross-sectional area of the recommended leads is shown in
Table 3. Check whether the residual current operated circuit breaker is in conformity with the normal operating conditions.
E 51 52 F
Suyang Quality, Rock Solid
SYCM1 Series Moulded Case Circuit Breaker SYCM1 Series Moulded Case Circuit Breaker
I.Range of Application
3. The current of the protective electric motor of the electromagnetic release is 12In±20%(A)
Moulded Case Circuit Breaker (MCCB)is one of the company's new circuit breakers which combined the international 4. If the applied voltage of the shunt release is between 70%~110% of the rated control power voltage, it can reliably
advanced design,manufacturing technology and develop . According to its rated limit short circuit sectional capacity (ICU), is breaking the circuit breaker.
divided into L-type (standard type), M-type (high break type), H-type (higher break type).It has the characteristics of small 5. When the supply voltage drops to the rage of 70%~35% of the rated working voltage of the under-voltage release,
size, high breaking, short flying arc and anti-vibration, and is an ideal product for land and ship use. Its rated insulation voltage the under-voltage release can reliably breaking the circuit breaker. If the supply voltage is below 35% of the normal-
800V (SYCM1-63 is 500V), suitable for AC 50HZ, 690V and the following circuit for continuous frequent conversion and motor voltage of the under-voltage release , the under-voltage release could prevent the breaker of closing; when the
infrequent start-up. Circuit Breaker has overload, short circuit and under-voltage protection device, which can protect the line supply voltage is above 85% of the rated working voltage of the under-voltage, the under-voltage could ensure the
and power equipment from being damaged.
breaking closing.
Vertical installation and horizontal installation
Meet the standards: IEC60947-2、GB14048.2
V. Appearance and Mounting Dimension
II.Types and Classification
flash barrier
SY CM A
A1 A1 flash barrier
Under-voltage release
Under-voltage release
G
H5
G1
H4
H3
Operation methods(2) F
F
Application code(1)
L1
C1
L2
E
B
L
C
22
E
Release Versions and Accessory codes 22
Pole
Rated limited short-circuit breaking capacity levels H2
H
Shell grade rated current W1 W1 W1
H1(max)
W2
Design NO. W1 W1
W
4P
Moulded Case Circuit Breaker
3P Table3
Yangzhou Suyang Electric Co., Ltd
F 53 54 F
Suyang Quality, Rock Solid
SYCM1L Series Leakage advanced design,manufacturing technology and develop . According to its rated limit short circuit sectional capacity (ICU), is
divided into L-type (standard type), M-type (high break type), H-type (higher break type).It has the characteristics of small
size, high breaking, short flying arc and anti-vibration, and is an ideal product for land and ship use. Its rated insulation voltage
Moulded Case Circuit Breaker 800V (SYCM1-63 is 500V), suitable for AC 50HZ, 690V and the following circuit for continuous frequent conversion and motor
infrequent start-up. Circuit Breaker has overload, short circuit and under-voltage protection device, which can protect the line
and power equipment from being damaged.
Vertical installation and horizontal installation .
Meet the standards: IEC60947-2、GB14048.2.
SY C
Alarms: both alarm and tripping is represented by I,
alarm without tripping is represented by II
4pole type code (see the below table), 3pole type has no code
Operation mode:
Manual operation type has no code;
Turning handle operation is represented by Z;
Motor operation is represented by D.
Shell grade
With leakage protection
Design NO.
III.Technical Parameters
Table 1 Release mode and accessories code
Release mode and
accessories code Auxiliary mounting and wiring connection mode
No accessories
Alarm contact
Shunt release
Auxiliary contact
Alarm contact
under-voltage release
Shunt release,
auxiliary contact
Leakage alarm mode I/II I/II
F 55 56 F
Suyang Quality, Rock Solid
SYCM1L Series Leakage Moulded Case Circuit Breaker SYCM1L Series Leakage Moulded Case Circuit Breaker
Appearance and mounting dimension of the circuit breaker rear connection
IV.The Conditions of Application,Mounting and Transportation
Normal condition of application:
a)The ambient air temperature is -5℃~+40℃, average temperature in 24 hours should less than +35℃.
Note: If the temperature is below -5℃ or above 40℃, consult the manufacturer before order
b)The elevation of the installation site should be less than 2000m.
c)The relative humidity of the atmosphere is not more than 50% when the ambient maximum temperature is
+40℃;and at lower temperatures there can be a higher relative humidity (eg. 20℃ 90%), take the condensation on
the surface of the product due to the temperature changes into account.
(mm)
Specification
3P 4P 3P 4P
SYCM1L-100
SYCM1L-250
SYCM1L-400
SYCM1L-630、800
Appearance
dimension Mounting dimension
Specification Pole
L1 L2 L3 L4 Mounting
a b holes(φ)
3 92 150 110 92 30±0.14 129±0.32 4-φ4.5
SYCM1L-100
4 122 150 110 92 60±0.14 129±0.32 6-φ4.5
The hole size of door
3 107 165 110 90 35±0.16 126±0.32 4-φ4.5 Emergency unlock
SYCM1L-250
4 142 165 110 90 70±0.16 126±0.32 6-φ4.5
VII. Turning Handle Operation Mounting Dimension
SYCM1L-400 4 198 257 147 110 94±0.20 194±0.43 6-φ7
SYCM1L-630/800 4 280 280 155 103 140±0.20 243±0.50 6-φ7 Specification SYCM1L-100 SYCM1L-250 SYCM1L-400 SYCM1L-800
Mounting dimension(H)
F 57 58 F
Suyang Quality, Rock Solid
SY CM E
Specification
Release Versions and Accessory codes
Pole
Operation methods
Rated limited short-circuit breaking capacity levels
Shell grade rated current
Electronic tripping
Design NO.
Moulded Case Circuit Breaker
Yangzhou Suyang Electric Co., Ltd
1. Elevation:≤2000m.
2. The ambient air temperature:-5℃~+40℃.
3. Withstand the effects of humid air.
4. Withstand the effects of salt mist or oil mist.
5. Main circuit installation category is III, and the remaining auxiliary circuit,control circuit installation category is II.
6. When the highest temperature is +40℃,the relative humidity of the air should not more than 50%, and at lower
temperatures there can be a higher relative humidity , take the condensation on the surface of the product due to
the temperature changes into account.
7. Maximum tilt is 22.5°.
8. The medium with no explosion-dangerous and is not sufficient to corrode the metal and to destroy the insulating
gas and conductive dust.
9. The installation place without rain or snow.
F 59 60 F
Suyang Quality, Rock Solid
SYCM1E Series Electronic Moulded Case Circuit Breaker SYCM1E Series Electronic Moulded Case Circuit Breaker
IV.Main functions and features VI. Main technical performance instructions
Intelligent controller is the core component of MCCB, it is used in motor protection or distribution protection.
Measurement, protection, control and communication functions can protect circuit and power equipment from damages like
overload, short circuit and grounding fault.
1.Using MCU micro processing controller, stable and reliable performance: the intelligent controller can supply power,
as long as one pahse is power on, and the current is not less than 20% of its rated value, it can ensure the normal
operation of the protection function;
2.Selectivity coordination has three sections protection: circuit breaker used for B category and other short circuit
protection device connected on the same circuit has selective coordination; Overload long delay inverse time, short circuit
delay(inverse time, time limit), short circuit instantaneous protection function parameter setting;
3.Parameter settings of action current and action time three section protection is adjustable in 4-10 gear: users can
adjust the controller settings according to load current requirements, and select corresponding functions (customize the
function required to specify when ordering); Intelligent molded case circuit breaker
SYCM1LE-630M/3300
4.High current instantaneous trip function: when the breaker is in closed operation, and the current is a high short Ui 690V Ue 400V
circuit current (≥ 20lnm), the magnetic tripping mechanism of circuit breaker can be directly tripped, double protection is L
Icu
50kA
Ics
35kA
GB 14048.2
IEC60947-2
H 100kA 65kA
5.Tripping test function: make the voltage of input circuit is DC12V; Ir1 400A-630A PUSH TO TRIP
Uimp 6kV
Cat:A 50Hz
In 630 A
6.Fault self-diagnosis function: to protect and detect working state and operation condition of the intelligent controller; Yangzhou Suyang Electric Co., Ltd.
7.Pre-alarm and overload indicator: When the load current reaches or exceeds the set value, corresponding light
source is derived; TEST
20
25
60
80 4
5
6 0.1
0.2 8
10
11
0.85
0.9
0.8
7 12
8.Double air gap technology of flux transfer trip: The utility model has the advantages of more reliable and stable
16 12 3 7 0.95
0.06
0.75
2.5 8 6 13
10 14 0.7 1
100 2 0.3 4
32 OFF 12 OFF OFF
Product SYCMIE SYCMIE(Z) SYCMIE(B) SYCMIE(X) SYCMIE(L) Model SYCMIE-125 SYCMIE-250 SYCMIE-400 SYCMIE-630 SYCMIE-800
type Programming type
Function Basic type Intelligent type Fire type Liquid crystal type
Overload and long Inm(A) 125 250 400 630 800
time delay setting
16/20/25/32/36/ 400/420/440/460/ 630/640/660/680/
Short circuit and short 40/45/50/55/60/ 125/140/160 200/250/280/
time delay setting In(A) 63/70/75/80/85/ 180/200/250 315/350/400
480/500/530/560/ 700/720/740/760/
90/95/125 600/630 780/800
Short circuit and
instantaneous setting
Overload and Ue(v) AC400V
pre-alarm indication
Ui(v) AC800V
Tripping test function
F 61 62 F
Suyang Quality, Rock Solid
SYCM1E Series Electronic Moulded Case Circuit Breaker SYCM1E Series Electronic Moulded Case Circuit Breaker
VII. Appearance and installation dimension Appearance and installation dimension of circuit breaker rear-panel wiring
5 10 0.85
20 60 6 0.1 11 0.9
25 80 4 0.2 8
0.8
3 7 7 12 0.95 5 10 0.85
16 12 0.06 20 60 6 0.1 11 0.9
25 80 4 0.2 8
0.75 0.8
2.5 8 6 13 3 7 7 12 0.95
16 12 0.06
10 14 0.7 1 0.75
100 2 0.3 4 2.5 6
32 OFF 12 OFF OFF 8 13
10 14 0.7 1
100 2 0.3 4
Ir1(A) t1(S) Ir2(XIr1) t2(S) Ir3(XIr1) Ir0(XIr1) 32 OFF 12 OFF OFF
SYCM1E-800 4 280 280 155 115.5 140±0.20 243±0.50 6-φ7 IX. Rotational handle installation dimension
F 63 64 F
Suyang Quality, Rock Solid
SYDW45 Series
SYDW45 series intelligent air circuit breaker (hereinafter referred to as breaker), it is suitable for distribution network
which is AC 50Hz, rated voltage up to 660V (690V) and below, 630A~6300A rated current. It is used in distribution of
power and protecting circuit from overload, short circuit, undervoltage, single-phase grounding fault hazard. Circuit breaker
Intelligent Air Circuit Breaker with intelligent protection function and precise selective protection can improve the reliability of power supply, avoid
unnecessary power outages. And it has an open communication interface, can carry out the "four remote", in order to meet
requirements of the control center and the automation system. The circuit breaker pulse pressure is 8000V at an altitude of
2000 meters (different altitude correction according to the standard, the maximum is not more than 12000V). This circuit
breaker has no intelligent controller or sensor, can used for identification of the isolator. Identification:
The circuit breaker complies with GB14048.2 “low voltage switchgear and control equipment, low voltage circuit
breaker” and IEC60947-2“ low voltage switchgear and control equipment, circuit breakers” etc.
classification
Classified by installation:
a.Fixed
b.Open frame
Divided by poles: 3p、4p
According to the operation mode:
a.Electric operation
b.Manual operation ( maintenance)
Release type
Intelligent controller, under voltage instantaneous (or delayed) release, shunt release.
G 65 66 G
Suyang Quality, Rock Solid
SYDW45 Series Intelligent Air Circuit Breaker SYDW45 Series Intelligent Air Circuit Breaker
III. Main technical parameters 5. Ground fault protection characteristics for the short delay and constant time-lag, see Table 5 limit action time and
return time, ground fault factory time setting for "OFF".
1. The basic parameters of the circuit breaker is shown in Table 1 Table 1 6. The operation performance of the circuit breaker is represented by the number of operation cycles, see Table 6.
Frame Size Rated ultimate short- Rated operation short- Rated short time Power loss(w) Table 6
Rated voltage
Rated Current Rated current circuit breaking capacity circuit breaking capacity withstand current Open
Fixed frame Number of operation Mechanical life (Times) Electrical life
Inm(A)
cycles per hour Mnintenance-free Mnintenance (Times)
2000 20 13500 20000 6500
400/690V
3200 20 10000 20000 3000
5. Working voltage of shunt release, undervoltage release, electric operating mechanism, release (closing) electromagnet,
intelligent release for circuit breaker is shown in Table 7.
Table 7
80/50
Rated voltage
Type
80/50
Shunt release
Undervoltage release
Electric operating mechanism
100/75
Release (closing) electromagnet
Intelligent release
Note 1: the arcing distance is zero. Note 2: the breaking capacity of upper and lower line are the same.
The derating coefficient of circuit breaker at different ambient temperature see Table 2 Note: Reliable operation voltage range of shunt release is (70%-110%) Us, release (closing) electromagnet and the
Table 2
electric operating mechanism is (85%-110%) Us.
Ambient temperature
Allowable continuous 8. Performance of circuit breaker under voltage release is shown in Table 8
working current Table 8
Note: in various ambient temperature conditions, measured circuit breaker import terminal temperature reached 110℃ as a benchmark. Type Undervoltage delay release Undervoltage instantaneous release
2. Release current setting Ir and tolerance are shown in Table 3 Table 3 Release action time Delay 1、3、5 s Instantaneous
Long time Short time delay(Ir2) Instantaneous(Ir3) Ground fault(Ir4)
break the circuit breaker
delay(Ir1) L-type M、H-type Tolerance L-type M、H-type Tolerance Tolerance
Release action time Circuit breakers are not closed
Maximum:1200A
Minimum:160A Circuit breaker can be reliably closed
G 67 68 G
Suyang Quality, Rock Solid
SYDW45 Series Intelligent Air Circuit Breaker SYDW45 Series Intelligent Air Circuit Breaker
IV. Basic function of M or L type controller V. Installation and appearance dimention of fixed circuit breaker
Connecting terminal SYDW45-2000、2000/4 fixed circuit breaker (see Figure 2)
There are 47 connecting terminals in circuit breaker, it is simple and easy to use, the wiring diagram is shown in Figure 1.
Other connection of intelligent controller 413(4P)
318(3P) Cupboard door
340(3P)
435(4P)
Control (Extended horizontal wiring)
power supply
Processing Figure 2
unit
85 29
95
105
Working
power
DC power module (SYDW45-3200、3200/4)fixed circuit breaker (see Figure 3)
493(4P)
Figure 1 378(3P)
Cupboard door
Note:
(1) If control power supply voltage of F, X and M is different, power supply is different.
(2) Terminal #35 can be directly connected to the power supply (automatic pre storage), also can be connected with
power supply when it is cascaded with a normally open button (manual pre storage). 86
(3) Terminal #6~#7 can output normally closed contact as users' requirements. 400(3P)
(Vertical wiring)
(4) Accessories are prepared by user. 515(4P)
(5) When working power supply of intelligent controller is DC power, general configuration is “built in” ( none
specified) DC power supply module, Terminal #1, #2 can be directly connected to the DC power. If users select "plug-
in" module, terminal #1, #2 can not be directly connected to the DC power, and DC power supply must be input from the
400(3P)
515(4P)
DC power module U1 (+), U2 (-), the two output terminals are respectively corresponding connect to the secondary
86
wiring terminal input 1 (+) and 2 (-).
F
G 69 70 G
Suyang Quality, Rock Solid
SYDW45 Series Intelligent Air Circuit Breaker SYDW45 Series Intelligent Air Circuit Breaker
VI. Installation and appearance dimention of open frame circuit breaker SYDW45-4000 open frame circuit breaker (see Figure 6)
42.5
461(connect) 494(connect)
507(separate) 540(separate)
375(3P) (Vertical wiring) 559(connect)
470(4P)
605(separate)
202.5 202.5
360(4P)
15
(Extended horizontal wiring)
50
Figure 4
Figure 6
Cupboard door
510(4P)
395(3P)
452
45.5
461(connect)
42.5
504(connect)
507(separate)
550(separate)
c (connect)
435(3P)
559(connect)
d (separate)
90
550(4P) 615(separate)
(Vertical wiring)
Note: size from panel
center to breaker
Center is about 206.5
325(3P)
440(4P)
155
15
(Extended horizontal wiring)
50
Figure 5 (Horizontal wiring)
Figure 7
G 71 72 G
Suyang Quality, Rock Solid
SYDW45 Series Intelligent Air Circuit Breaker SYDW45 Series Intelligent Air Circuit Breaker
SYDW45-6300、6300/4 In=4000A、5000A open frame circuit breaker (see Figure 8) SYDW45-6300、6300/4 In=6300A open frame circuit breaker (see Figure 10)
952(4P)
335(3P) 888 Cupboard door
Cupboard door 1067
837(3P)
773 1003
452
452
42.5
42.5
504(connect)
504(connect)
550(separate)
550(separate)
569(connect)
569(connect)
615(separate)
813(3P) 615(separate)
1043
928(4P)
Note: size from panel
Note: size from panel center center to breaker
to breaker Center is about Center is about 304
189(3P), 264.5(4P)
In=4000A,The thickness of
60
wiring copper bar:20mm
703(3P)
818(4P)
100
1037
938
50 28
50
N
(Horizontal wiring)
(Horizontal wiring)
Figure 8
Figure 10
504(connect)
550(separate) 1250A 80X5 2 4000A 120X10 4
569(connect)
615(separate)
1600A 100X5 2 5000A 120X10 5
Note: size from panel
center to breaker 2000A 100X5 3 6300A 120X10 6
Center is about 264.5
2500A 100X5 4
50
(Horizontal wiring)
Figure 9
G 73 74 G
Suyang Quality, Rock Solid
19 . 5
268
51 16
Inm a mm b mm c mm
2000 306 345 0
3200、4000/3 366 405 0
4000/4 306 345 0
6300 366 405 0
241 241
Current Current
specification specification 205
7 50 55 50
5000A 30
25
50
50
134
4000A 20
(Horizontal wiring)
395
134
112
55
base point
150 69.5 196
11 778(3P) 11
285 11
898(4P)
290
G 75 76 H
Suyang Quality, Rock Solid
SYG1 Series Auto over/under Voltage Protector SYG1 Series Auto over/under Voltage Protector
I. Product overview IV. Connection diagram V. Appearance and installation dimention
load load
SYG1 series auto over/under voltage protector (hereinafter referred to as protector) is a high-tech new product 35 66 66
74
developed with the latest technology. When the power supply line is over voltage and under voltage, the protector can
cut off the circuit rapidly and safely, to avoid abnormal voltage into the terminal resulting in accidents. When the
normal operation of the terminal. Protector is suitable for single phase AC voltage 220V, frequency 50Hz, rated 270±5V Overvoltage Working voltage:AC380V 50Hz
Undervoltage protection:AC300V±15V SYG1-40 IN:40A Overvoltage protection:AC460V±15V
170±5V Undervoltage Delay Time:≤60S 270±5V Overvoltage Undervoltage protection:AC300V±15V
84
84
Delay Time:≤60S
81
operating current 90A loads.The protection of single-phase power supply equipment caused by single-phase line 1-2min Delayed protect 170±5V Undervoltage
over voltage due to neutral line fault is mainly used for the protection of the distribution line of the household, Yangzhou Suyang Electric Co., Ltd. AC220V Power Supply
a) The ambient air temperature shall not exceed +40℃, and the temperature within 24h shall not exceed +35℃;
b) The ambient air temperature limit is -5℃. VI. Structure features and working principle
Altitude:≤2000m;
1、 When the single-phase line is under voltage, the circuit is cut off, the single-phase voltage is restored to normal,
Atmospheric condition:
then is reset automatically after the delay, without manual operation.
When the maximum temperature is +40℃, the relative humidity of the air should not exceed 50%.
2、When the line appears transient or transient over-voltage, the protection will not cause misoperation.
Lower temperatures permit higher relative humidity, such as 90%. at 20 degrees, and appropriate measures should 3、The line is out of contact, then it causes the unstable voltage or a sudden power failure followed by a sudden call, the
be taken for the occasional condensation due to temperature changes. protector does not switch on the circuit.
Pollution level: 3 4、When the line fault voltage is the highest, the protector itself is not damaged.
In a medium that has a weatherproof device and is free from explosion, there is not enough gas in the medium to 5、Voltage protection range: <40A: 0-450V; 50A/63A: 0-600V.
corrode the metal and destroy the insulation, and there is a lot of conductive dust; 6、Indicator lamp: four double color LED light-emitting diode respectively: normal (green), delay (yellow), overvoltage
The installation surface and the vertical inclination are not more than ±5℃, installed and fixed in places where there is (green), undervoltage (blue).
no significant shaking or impact vibration. 7、Installation method is the same as DZ47 (C45) miniature circuit breaker which is the same size with it, it is directly
Installation category: III connected with the switching device in series, used in the main circuit. Easy installation, low power consumption, long
service life.
8、The auto over/under voltage protector is sampling and comparing with the integrated chip to determine whether the
input voltage of the main circuit is abnormal, if the circuit is abnormal then trigger protective circuit, it disconnect the main
III. Model and technical parameter circuit load through the built-in relay, and the protector enters the power-off protection state until the input voltage
returns to normal range, start delay 1 minutes after coincidence.
SY G1 -
Rated working voltage VII. Installation and use
Rated current of main circuit
S:36mm width(The connection mode is down-in and up-out) Installation: Standard 35mm rail installation. If the product appearance and size similar to DZ47, it can be
auto over/under voltage delayed protector merged installation.
Read the instruction manual before installation, and then according to the wiring diagram on line. The
Yangzhou Suyang Electric., Ltd.
protector marked on the inlet end and the outlet end of the English letter "N" indicates the zero line, "L" phase,
"IN" into the line side, "OUT" represents the outlet end.
Main technical data and parameters (see table below) Instructions of SYG1 auto over/under voltage delayed protector : when the power supply is connected, the
Product model SYG1 auto over/under voltage delayed protector power indicator lamp and the time delay protection lamp are simultaneously lighted, and the controller is in the
Work power AC220V 50/60Hz detection voltage state. When the voltage of power supply is normal, after the delay protection, the control
Protected type Over voltage protection, under voltage protection terminal is provided with power output, and the main circuit is loaded with electricity. In the process of use,
Protection parameter Overpressure value:AC275±5V;AC175±V(Special requirements can be customized) when the overvoltage or undervoltage, the corresponding indicator light, delayed protection open, until the
Action delay time 1S~6S voltage returned to normal when the start time, 30~60s coincidence, load power.
Protection time of SYG1 series auto over/under voltage protector is 1s, and can turn off power supply. The
Reclosing time 30S~60S(Start clocking after the voltage has returned to normal)
second automatic transmission starting from the voltage returns to normal and starts timing in 1min. The over -
Turn on Delay Time 2S
Restore power supply undervoltage range protected by the protector is fixed at the factory, we can customize according to your
parameters Overvoltage recovery difference:242±5V Undervoltage recovery difference:187±5V
special requirements.
Product power consumption ≤2VA
contact rating 250VAC 20A/250VAC 30A(Resistance)
Connection mode up-in and down-out/down-in and up-out
Use type AC-15 DC-13 VIII.Storage conditions of protectors
Mechanical life 10 6 times
Installation method 35mm rail mounting (Combination installation with DZ47) Temperature: -25℃~+40℃;
Relative humidity (25℃) ≤ 85%;
Keep away from rain and snow.
H 77 78 H
Suyang Quality, Rock Solid
SYL1 Series
SYL1-B/4-60KA、 SYL1-B/4-80KA、 SYL1-B/4-100KA Series SPDs are suitable for TT、IT、TN-S、TN-C、
TN-C-S power supply systems (AC 50/60Hz,≤380V), they are used in equipotential bonding at the interface between
LPZ0A or LPZ0B and LPZ1, to protect the power grid from lightning strike or surge overvoltage. This SPD is designed
Surge Protection Device according to IEC-61643-1、 GB5007-94, it can discharge 100kA thunder-strike current, the shell is installed in a
35mm guide rail, these's a internal failure release device, when the SPD with a breakdown failure due to overcurrent and
overheating, the device can separate it from the grid and the status indicator displays from green to red.
Protection Class
Un(V)
Uc(V)
Ip(10/350μS)(kA)
Q(As)
(8/20μS)In(kA)
(8/20μS)Imax(kA)
Up(kA)
Temp(℃)
Installation 35mm electric guide rail 35mm electric guide rail 35mm electric guide rail
I 79 80 I
Suyang Quality, Rock Solid
SYL1-C Series Surge Protection Device SYL1-D Series Surge Protection Device
I. Product Description I. Product Description
SYL1-C Series SPD is suitable for TT、 IT、 TN-S、 TN-C-S power supply systems (AC 50/60Hz,≤ SYL1-D Series SPD is suitable for TT、 IT、 TN-S、 TN-C-S power supply systems (AC 50/60Hz,≤
380V), it is used in equipotential bonding under lighting. This SPD is designed according to IEC61643-1、 380V), it is used in equipotential bonding under lighting. This SPD is designed according to IEC61643-1、
GB5007-94, the shell is installed in a 35mm guide rail, these's a internal failure release device, when the SPD GB5007-94, the shell is installed in a 35mm guide rail, these's a internal failure release device, when the SPD
with a breakdown failure due to overcurrent and overheating, the device can separate it from the grid and the with a breakdown failure due to overcurrent and overheating, the device can separate it from the grid and the
status indicator displays from green to red. status indicator displays from green to red.
Model SYL1-D
Model SYL1-C
Un(V) Uc(V)
Installation 35mm electric guide rail Installation 35mm electric guide rail
Common Model SYL1 SYL1 Common Model SYL1 SYL1
Alarm Model SYL1 Alarm Model SYL1 SYL1
Remote Control Contact Model SYL1
Remote Control Contact Monitoring SYL1 SYL1
Single-phase Bipolar Combined
into A single phase system SYL1
I 81 82 I