Biowell
Biowell
Biowell
DISINFECTION
Patients deserve 100% safety water more than just quality water.
At Biowell,we deliver state-of-the-art ozone disinfection technology specifically for use in the
Dentistry. We take our commitments to quality seriously and strive to continually improve our
products in order to ensure we are providing the highest quality ozone disinfection solutions
available. We are dedicated to providing our customers with complete solutions for their needs
The high levels of microorganisms found in DUWL output water derive from microbial biofilms formed on the
internal surfaces of DUWLs. These biofilms are composed mainly of hydrated complex exopolysaccharides
secreted by bacteria.
As the biofilm grows and develops, planktonic cells and by-products such as bacterial endotoxins are released
into the water and are subsequently aerosolised by dental chair supplied instruments including turbine dental
handpieces and ultrasonic scalers.
Besides the bad odors coming out of these dirty water lines, the microbial biofilm represents a source of infection
to patients, especially who have a deficient immune system or the elderly.
Dental patients and dental healthcare staff become exposed to and can inhale the fine aerosols containing
microorganisms, fragments of biofilm and bacterial endotoxins. When this occurs, the potential for contracting
serious illness such as Legionnaires Disease is increased exposing the immunocompromised to unnecessary risk.
1
Taking the benefits of ozone, Biowell provides a more effective and economical way to offer consistent and
unconditional supply of bacteria-free water for dental treatment, and keep waterlines safe and clean. Our solution
accomplish a simultaneous disinfection of DUW and DUWL together, providing both an antimicrobialcleaner and
organic irrigant for enhanced patient care at all times.
Designed for self-contained water systems, the CDU favors the water
disinfection at point -of-use prior to bottle filling, with capability up to
180 liters per hour. This compact product enables clinics to use of ozonated water
for multiple disinfection applications.
CDU
MWDS-mini MWDS
MWDS series is designed for dental unit water and waterlines disinfection within direct feed configurations.
Automatic sanitation function without manually dosing chemical gives clinics a peace of mind when it comes to
DUWL disinfection.
PROUDLY CERTIFIED BY
Product Features
Continuous flow of dissolved ozone residual in the water as disinfection treatment in the dental unit waterlines
UV units are generally used to control the bacteria levels in the water, but bacteria such as Pseudomonas species will
continue to develop, producing biofilm throughout the system and compromising the water quality.
To achieve biofilm control, injecting or circulating a disinfectant throughout the system is necessary. Dissolved ozone
solution provides an effective cleaning and biocidal treatment, replacing chemical processes previously used.
Ozone does not damage plumbing fittings or pipes, nor affect the pH of water. Moreover, it leaves no chemical by-products in water, as it
breaks down to give di-atomic oxygen.
Ozonated water leaves no biocidal traces so there is no contamination risk in bonding procedures and does not interfere with dental
material bond strengths in endodontic.
3
Enhance Your Protocol & Exceed Regulatory Standard
Continuous disinfection on-demand
System hygiene is maintained within the most stringent water quality standards.
Zero by-product but oxygen, Harsh chemical residue and Scattered and ineffective
bacteria-free guaranteed chemical handling
4
Chemical Free Infection Control Solutions for Dental Clinics
CDU MWDS Series
1. Bacteria-free water filling for bottle 6. Bacteria-free water for DUW
2. Instruments pre-wash 7. Automatic DUWL disinfection
3. Hand wash MWDS mini for clinics with 1-4 dental chairs
CDU
4. water oral rinse MWDS for clinics with 5-10 chairs
5. Surface disinfection (intraoral scanner,
dentures, seat, counter)
2
7
Tools Pre-wash
MWDS series
Hand Wash
3
CDU
Bacteria Fee Water
for Cup Fill 4 6
5
Bacteria Free Water
Surface Disinfection
for Bottle
Technology Features
The world leading dissoled ozone technology for infection control
NOx*-free
√ Full time ozone generator self monitoring & operation status display
√ Built-in off gas destruct unit
5 Automatic destructs excessive undissolved ozone before dispensing
Meets international OSHA off-gas standards
BIOWELL OZONATED WATER EFFICIENCY TEST
Test Item 0sec 5sec 15sec Reduction(%)
Staphylococcus aureus (CFU/ml) 5.4x105 Not Detected Not Detected >99.999%
The above test results by SGS show the efficiency of Biolux’s ozonated water with 5 second and 15
second exposure times for eliminating various microorganisms up to 99.999% and chemicals up to
100%. SGS is the world’s leading inspection, verification, testing and certification company. SGS is
recognized as the global benchmark for quality and integrity.
6
SPECIFICATIONS
Model No. CDU MWDS mini MWDS
Con uration
Type of Ozone Generators Indirect Electrolytic Ozone Generation (iEOG)
Source of Ozone Water electrolysis
Control Method Sensor Flow switch
Application Method Point-of-use Point-of-entry
Performance
Output Pressure*1 0.3kg/cm2 (4.4 psi) ≤ Input water pressure (Max. 3kg/cm2 [42.7 psi])
Ozonated Water Concentration *1, *2, *3 12-4 ppm / 8-2 ppm 8~0.5 ppm >0.5 ppm
Capacity Recommendations
100 LPH / 200 LPH ≈ 300 LPH ≈ 750 LPH
(Total water volume in connecting waterlines)
Operating Requirements
□ 100V/60Hz □ 120V/60Hz
Power Supply
□ 220V/50Hz □ 240V/50Hz
100 – 120V 900 W
Power Consumption 60 W
200 – 240V 700 W
Quality Municipal Water Source *3
Pressure 2.0 - 4.0 kg/cm2 (29 - 57 psi)
Input Water
Temperature 5 - 30℃ (41 - 86 ℉ )
Piping Diameter 3/8” 1”
Room Temperature 5 - 35℃ (41 - 95 ℉ )
Environment
Room Conditions Well Ventilated Environment
Design Parameters
Depth (D) 176mm(6.9in) 320mm(12.6in)
Dimension Width (W) 330mm(12.9in) 550mm(21.7in)
Height (H) 435mm(17.1in) 700mm(27.6in)
Leveling Legs 5mm(0.2in) 85mm(3.3in)
Net Weight 7.5kg(15.5lb) 50kg(110lb)
Frame Material ABS 304 SS casing
Pump Material NA 304 SS impeller
Installation Wall mount / Counter top Stationary
Noise Level ≤40 Max. 60 ‐65 bBA (at1m)
Remark:
*1. Results are based on input water pressure given at 3 kg/cm 2 (43.5 psi).
*2. Ambient room temperature: 20℃ (68 ℉ ).Using cool water 10℃ (50 ℉ ) or below will attain best results.
*3. Recommend pH between 6 - 8 with a standard water hardness less than 120 ppm with water electrical conductivity: ≤500 us/cm. Most standard municipal water quality is
adequate.
© BES Group 2014 August.
DISTRIBUTED BY: