Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
27 views

Ident Configuration Guide 2023-11

The document provides guidance on selecting SIMATIC RF identification systems. It outlines the key SIMATIC RF families and their characteristics for different applications based on factors like read distance, tag memory, environmental tolerance, reader dimensions, and multitag capabilities. System interfaces are also described for integrating the identification systems.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views

Ident Configuration Guide 2023-11

The document provides guidance on selecting SIMATIC RF identification systems. It outlines the key SIMATIC RF families and their characteristics for different applications based on factors like read distance, tag memory, environmental tolerance, reader dimensions, and multitag capabilities. System interfaces are also described for integrating the identification systems.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 93

SIMATIC IDENT

Configuration Guide

Unrestricted | © Siemens 2023 | All rights reserved.


Content
Important notes:
Select and configure a SIMATIC RF Family ................................ …… 4
RF200
Family Matrix .................................................................................. 4 All selection possibilities of this
System Interfaces ......................................................................... 17
SIMATIC Ident Configuration Guide
RF300
can also be found in the TIA Selection Tool.
Family Matrix ................................................................................ 23
System Interfaces .......................................................................... 36 This tool is available at:
RF600 http://www.siemens.com/tst
Family Matrix ............................................................................... 41
System Interfaces .......................................................................... 49
Other functional highlights of the selection tool:
RF1000
Family Matrix ............................................................................... 53 • Create order lists
System Interfaces ......................................................................... 56 • Get price information by application to the mall
• Select other automation components
RF Handheld Reader ........................................................................ 61 (control devices, IO-Systems,
Conveyor Belt Gate ---------------------------------------------------------------------- .64 industrial communication)
• Network view of all components
Configure an Optical Identification System • Retrieve and compare technical data
MV500 System Interfaces ................................................................ 66 • … and much more
MV300 System Interfaces ................................................................ 81
System interfaces for general purpose serial devices
Bill of Materials Guide All current wireless approvals can be found
RF18xC / CI .................................................................................. 86 on the Internet at:
RF166C ........................................................................................ 88 http://www.siemens.com/rfid-approvals
RF360R ........................................................................................ 89
Bulk Cable and Connectors ............................................................... 90
The newest version of this configuration guide
is published at:
https://support.industry.siemens.com/cs/ww/en/view/67384964

Corrections mail to: markus.haeuser@siemens.com

Unrestricted | © Siemens 2023 | All rights reserved.


Each SIMATIC RF Family has characteristics that orients it to a particular range of applications:
■ The first step is to understand the application by asking the right questions. Out of this process, the best-suited SIMATIC RF family can be determined
■ A reader and tag combination within the specific family can be selected using the SIMATIC RF family matrix pages
■ Within the chosen family, a network interface to the control system can be selected using the system interfaces pages

Technology HF UHF Environment Heavy Heavy


RF1000 RF200 RF300 RF600 What kind of RF200 RF300 RF600
environmental
What is the basic
extremes will the
RF technology?
tags be subjected
125 kHz + 13.56 MHz 13.56 MHz 868/915 MHz 220°C IP68 220°C IP68 230°C
13.56 MHz to? IP68

Read Distance Shorter Longer Reader Dimensions Smallest Largest


How far away can RF1000 RF300 RF200 RF600 RF200 RF300 RF600
the tag be from the How much space will there be
reader antenna for mounting the reader/
system and still be antenna?
seen? 30 mm 210 mm 650 mm 8 meters M8 x 38 M12 x 40 75 x 75 x 20

Tag Memory Less More Multitag Mode Less More


RF600 RF200 RF300 RF200 RF300 RF600
How many bytes Will there be more
are required to be than one tag in the
stored on the tag? RF field at a time?
384 bytes 8 kbytes 64 kbytes 1 1 100+

Metal Effects Direct Mount Spacer Mount Tag Speed Slower Faster
RF300 RF600 RF200 RF200 RF300 RF600
Do tags and How fast will the
reader need to be tag be traveling
mounted on or through the RF
around metal? Direct with Direct with Spacer Mount field?
26 kbits/sec 100 kbits/sec 300 kbits/sec
reduction reduction

Tag Dimensions Smallest Largest Air Interface Protocol Siemens Standard


RF200 RF300 RF600 RF300 RF200 RF600 RF1000
Are there any
What is the
requirements
smallest tag size
regarding the air
available? ISO15693/14443 Legic,
Ø 4 x 5 mm Ø 4 x 5 mm Ø 21 x 20 interface protocol? Siemens/ ISO 18000
mm ISO15693/14443 ISO 15693 -62/ -63 Emxx/Hitag

3 Unrestricted | © Siemens 2023 | All rights reserved.


RF200
Family Matrix
13.56 MHz – passive tags

4 Unrestricted | © Siemens 2023 | All rights reserved.


D165 D261 D100 D200 D400 D160 D460 D560
RF200 Antennas 6GT2 600-1AB00-0AX0
112 byte EEPROM
6GT2 600-1AA01-0AX0 6GT2 600-0AD10 6GT2 600-1AD00 -0AX0 6GT2 600-4AD00 2 6GT2 600-0AB10 6GT2 600-4AB00 6GT2 600-5AB00
316 byte EEPROM 112 byte EEPROM 256 byte EEPROM kbyte FRAM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM
Family Matrix
13.56 MHz
Passive Tags
Operational temperature range -25°C to 85°C -25°C to 85°C -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 175°C -40°C to 100°C -40°C to 90°C
Dimensions (L x W x D) mm 86 x 54 x 0.3 55 x 55 x 0.3 85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8 Ø 16 x 3 Ø 16 x 3 Ø 16 x 3
Ingress Protection (IP) rating IP65 IP65 IP68 IP67 IP67 IP68/IPx9K IP67/IPx9K IP68/IPx9K

RF210R/ RF210M
6GT2 821-1AC10, RS422
6GT2 821-1AC32 / -1BC32, IO-Link* Integrated 1-10/ 12 1-8/ 9 1-8/ 9
6GT2 823-0AA00, Handheld (RS422) (0.04-0.39/ 0.47) (0.04-0.31/ 0.35) (0.04-0.31/ 0.35
M18 x 71

RF220R
6GT2 821-2AC10, RS422
6GT2 821-2AC32 / -2BC32, IO-Link* Integrated 1-20/ 22 1-18/ 20 1-18/ 20
(0.04-0.79/ 0.87) (0.04-0.71/ 0.79) (0.04-0.71/ 0.79
M30 x 71

RF240R
6GT2 821-4AC10, RS422
6GT2 821-4AC40, RS232 (ASCII) Integrated 2-80/ 94 2-60/ 70 2-84/ 95 2-69/ 78 2-80/ 90 1-33/ 37 1-30/ 34 1-30/ 34
6GT2821-4AC32 / -4BC32, IO-Link* (0.08-3.15/ 3.70) (0.08-2.36/ 2.76) (0.08-3.31/ 3.74) (0.08-2.72/ 3.07) (0.08-3.15/ 3.54) (0.04-1.30/ 1.46) (0.04-1.18/ 1.34) (0.04-1.18/ 1.34)
50 x 50 x 30

RF250R ANT 1
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII) 5-95/ 110 2-90/ 110 5-95/ 115 5-90/ 100 10-95/ 110 2-35/ 45 2-30/ 40 2-30/ 40
6GT2821-5AC32 / -5BC32, IO-Link* (0.20-3.74/ 4.33) (0.08-3.54/ 4.33) (0.20-3.74/ 4.53) (0.20-3.54/ 3.94) (0.39-3.74/ 4.33) (0.08-1,38/ 1.77) (0.08-1.18/ 1.57) (0.08-1.18/ 1.57)
6GT2 398-1CB00, ANT 1
75 x 75 x 20
RF250R ANT 3
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII) 1-23/ 30 1-21/ 27 1-21/ 27
6GT2821-5AC32 / -5BC32, IO-Link* (0.04-0.91/1.18) (0-0.83/ 1.06) (0.04-0.83/ 1.06)
6GT2 398-1CD40-0AX0, ANT 3
28 x 50 x 10
RF250R ANT 8
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CF10, ANT 8
Ø8 x 38
RF250R ANT 12
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII) 1-12/ 17 1-10/ 14 1-10/ 14
6GT2821-5AC32 / -5BC32, IO-Link* (0.04-0.47/ 0.67) (0.04-0.39/ 0.55) (0.04-0.39/ 0.55
6GT2 398-1DC10, ANT 12** Ø12 x 40

Holder Holder Holder


(6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 390-0AA00) Spacer Spacer Spacer
20 mm spacer 20 mm spacer 20 mm spacer (6GT2 690-0AG00) (6GT2 690-0AG00) (6GT2 690-0AG00)
Accessories (6GT2 190-0AA00) (6GT2 190-0AA00)
(6GT2 190-0AA00) Angle pattern body Angle pattern body Angle pattern body
Fixing pocket Fixing pocket Fixing pocket (6GT2690-0AN00) (6GT2690-0AN00) (6GT2690-0AN00)
(6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2 190-0AB00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
5 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D165 D261 D100 D200 D400 D160 D460 D560
RF200 Antennas 6GT2 600-1AB00-0AX0
112 byte EEPROM
6GT2 600-1AA01-0AX0 6GT2 600-0AD10 6GT2 600-1AD00 -0AX0 6GT2 600-4AD00 2 6GT2 600-0AB10 6GT2 600-4AB00 6GT2 600-5AB00
256 byte EEPROM 112 byte EEPROM 256 byte EEPROM kbyte FRAM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM
Family Matrix
13.56 MHz
Passive Tags
Operational temperature range -25°C to 85°C -25°C to 85°C -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 175°C -40°C to 100°C -40°C to 90°C
Dimensions (L x W x D) mm 86 x 54 x 0.3 55 x 55 x 0.3 85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8 Ø 16 x 3 Ø 16 x 3 Ø 16 x 3
Ingress Protection (IP) rating IP65 IP65 IP68 IP67 IP67 IP68/IPx9K IP67/IPx9K IP68/IPx9K

RF250R ANT 18
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link* 1-18/ 26 1-17/ 21 1-17/ 21
6GT2 398-1DA10, ANT 18 (0.04-0.71/ 1.02) (0.04-0.67/ 0.83) (0.04-0.67/ 0.83)
Ø18 x 40

RF250R ANT 30
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link* 1-23/ 30 1-21/ 27 1-21/ 27
6GT2 398-1DD10, ANT 30 (0.04-0.91/ 1.18) (0.04-0.83/ 1.06) (0.04-0.83/ 1.06)
Ø30 x 40

RF260R

6GT2 821-6AC10, RS422


6GT2 821-6AC40, RS232 (ASCII)
6GT2 821-6AC32 / -6BC32, IO-Link* Integrated 2-120/ 135 2-75/ 90 2-110/ 130 2-100/ 120 2-90/ 120 2-40/ 45 2-40/45 2-40/45
(0.08-4.72/ 5.31) (0.08-2.95/ 3.54) (0.08-4.33/ 5.12) (1.18-3.94/ 4.72) (0.08-3.54/ 4.72) (0.08-1.57/ 1.77) (0.08-1.57/ 1.77) (0.08-1.57/ 1.77)

RF280R

6GT2 821-8AC10, RS422 Integrated


6GT2 821-8AC40, RS232 (ASCII) 10 -160/ 190 20-110/ 150 10-160/ 200 20-140/ 185 5-150/ 180 2-55/ 70 2-55/ 70 2-55/ 70
(0.39-6.3/ 7.48) (0.79-4.33/ 5.91) (0.39-6.3/ 7.87) (0.79-5.51/ 7.28) (0.20-5.91/ 7.09) (0.08-2.17/ 2.76) (0.08-2.17/ 2.76) (0.08-2.17/ 2.76)

Holder Holder Holder Spacer Spacer Spacer


(6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 690-0AG00) (6GT2 690-0AG00) (6GT2 690-0AG00)
20 mm spacer 20 mm spacer 20 mm spacer
Accessories (6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 190-0AA00)
Angle pattern Angle pattern Angle pattern
Fixing pocket Fixing pocket Fixing pocket body body body
(6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2690-0AN00) (6GT2690-0AN00) (6GT2690-0AN00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
6 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D165 D261 D100 D200 D400 D160 D460 D560
RF200 Antennas 6GT2 600-1AB00-0AX0
112 byte EEPROM
6GT2 600-1AA01-0AX0 6GT2 600-0AD10 6GT2 600-1AD00 -0AX0 6GT2 600-4AD00 2 6GT2 600-0AB10 6GT2 600-4AB00 6GT2 600-5AB00
256 byte EEPROM 112 byte EEPROM 256 byte EEPROM kbyte FRAM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM
Family Matrix
13.56 MHz
Passive Tags
Operational temperature range -25°C to 85°C -25°C to 85°C -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 175°C -40°C to 100°C -40°C to 90°C
Dimensions (L x W x D) mm 86 x 54 x 0.3 55 x 55 x 0.3 85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8 Ø 16 x 3 Ø 16 x 3 Ø 16 x 3
Ingress Protection (IP) rating IP65 IP65 IP68 IP67 IP67 IP68/IPx9K IP67/IPx9K IP68/IPx9K

RF290R
6GT2 821-0AC12, RS232, RS422 ANT D1

10-180/ 250 5-130/ 180 10-180/ 250 10-170/240 10-170/240 1-65/90 1-60/85 1-60/85
(0.39-7.09/ 9.84) (0.39-5.12/ 7.09) (0.39-7.09/ 9.84) (0.39-6.69/ 9.45) (0.39-6.69/ 9.45) (0.04-2.56/ 3.54) (0.04-2.36/ 3.35) (0.04-2.36/ 3.35)
6GT2 698-5AC00
75 x 75 x 20

ANT D5

1-350/ 450 1-300/ 400 1-400/ 500 1-400/ 500 1-300/ 375 1-130/ 180 1-120/ 160 1-120/ 160
6GT2 698-5AA10 (0.04-13.78/ 17.72) (0.04-11.81 / 15.75) (0.04-15.75/ 19.69) (0.04-15.75/ 19.69) (0.04-11.81/ 14.76) (0.04-5.12/ 7.09) (0.04-4.72/ 6.30) (0.04-4.72/ 6.30)
380 x 380 x 110

ANT D6
1-400/ 500 1-350/ 450 1-550/ 650 1-500/ 600 1-500/ 650
6GT2 698-5AB00
(0.04-15.75/ 19.69) (0.04-13.78 / 17.72) (0.04-21.65/ 25.59) (0.04-19.69/ 23.62) (0.04-19.69/ 25.59)
580 x 480 x 110

ANT D10

1-350/ 450 1-350/ 450 1-500/ 600 1-450/ 550 1-400/ 500
6GT2 698-5AF00 (0.04-13.78/ 17.72) (0.04-13.78 / 17.72) (0.04-19.69/ 23.62) (0.04-17.72/ 21.65) (0.04-15.75/ 19.69)
1150 x 365 x 115

Covering hood Holder Holder Holder


for ANT D6 (6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 390-0AA00) Spacer Spacer Spacer
20 mm spacer 20 mm spacer 20 mm spacer (6GT2 690-0AG00) (6GT2 690-0AG00) (6GT2 690-0AG00)
Accessories (6GT2 690-0AD00)
(6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 190-0AA00) Angle pattern body Angle pattern body Angle pattern body
Fixing pocket Fixing pocket Fixing pocket (6GT2690-0AN00) (6GT2690-0AN00) (6GT2690-0AN00)
(6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2 190-0AB00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
7 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D117 D127 D421 D521 D422 D522
RF200 Antennas
6GT2 600-0AG00 6GT2 600-0AF00 6GT2 600-4AE00 6GT2 600-5AE00 6GT2 600-4AF00 6GT2600-5AF00
112 byte EEPROM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 6GT2600-5AF00-0AX0
Family Matrix 8 kbyte FRAM

13.56 MHz
Passive Tags
Operational temperature range -40°C to 125°C -40°C to 125°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø4 x 5.2 Ø 6 x 5.8 Ø10 x 4.5 Ø10 x 4.5 Ø20 x 6 Ø20 x 6 ; Ø18 x 5.2
Ingress Protection (IP) rating IP68 IPx9K IP68/ IPx9K IP67/ IPx9K IP67/ IPx9K IP68 IP68

RF210R/ RF210M
6GT2 821-1AC10, RS422
6GT2 821-1AC32 / -1BC32, IO-Link* Integrated 0-2/ 2 0-3/ 4 0-3/ 4 1-9/ 10 1-8/ 9
6GT2 823-0AA00, Handheld (RS422) (0-0.08/ 0.08) (0.0-0.12/ 0.16) (0-0.12/ 0.16) (0.04-0.35/ 0.39) (0.04-0.31/ 0.35)
M18 x 71

RF220R
6GT2 821-2AC10, RS422
6GT2 821-2AC32 / -2BC32, IO-Link* Integrated 1-12/ 14 1-10/ 12
(0.04-0.47/ 0.55) (0.04-0.39/ 0.47)
M30 x 71

RF240R
6GT2 821-4AC10, RS422
6GT2 821-4AC40, RS232 (ASCII) Integrated 1-12/ 15 1-10/ 12
6GT2821-4AC32 / -4BC32, IO-Link* (0.04-0.47/ 0.59) (0.04-0.39/ 0.47)
50 x 50 x 30

RF250R ANT 1
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CB00, ANT 1 75 x 75 x 20

RF250R ANT 3
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII) 1-12/ 15 1-12/ 15
6GT2821-5AC32 / -5BC32, IO-Link* (0.04-0.47/ 0.59) (0.04-0.47/ 0.59)
6GT2 398-1CD40-0AX0, ANT 3 28 x 50 x 10
RF250R ANT 8
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII) 0-2/ 3 0-3/ 4 0-3/ 4 0-3/ 4
6GT2821-5AC32 / -5BC32, IO-Link* (0-0.08/ 0.12) (0-0.12/ 0.16) (0-0.12/ 0.16) (0-0.12/ 0.16)
6GT2 398-1CF10, ANT 8 28 x 50 x 10
RF250R ANT 12
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII) 0-3/ 4 0-4/ 5 0-2/ 4 0-3/ 4 0-7/ 10 1-7/ 9
6GT2821-5AC32 / -5BC32, IO-Link* (0-0.12/ 0.16) (0-0.16/ 0.2) (0-0.12/ 0.16) (0-0.12/ 0.16) (0-0.28/ 0.39) (0.04-0.28/ 0.35)
6GT2 398-1DC10, ANT 12** Ø8 x 38

Accessories

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
8 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D117 D127 D421 D521 D422 D522
RF200 Antennas
6GT2 600-0AG00 6GT2 600-0AF00 6GT2 600-4AE00 6GT2 600-5AE00 6GT2 600-4AF00 6GT2600-5AF00
112 byte EEPROM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 6GT2600-5AF00-0AX0
Family Matrix 8 kbyte FRAM

13.56 MHz
Passive Tags
Operational temperature range -40°C to 125°C -40°C to 125°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø4 x 5.2 Ø 6 x 5.8 Ø10 x 4.5 Ø10 x 4.5 Ø20 x 6 Ø20 x 6 ; Ø18 x 5.2
Ingress Protection (IP) rating IP68 IPx9K IP68/ IPx9K IP67/ IPx9K IP67/ IPx9K IP68 IP68

RF250R ANT 18
6GT2 821-5AC10, RS422 0-3/ 5 0-4/ 5 1-8/ 14 1-10/ 12
6GT2 821-5AC40, RS232 (ASCII) (0-0.12/ 0.20) (0-0.16/ 0.20) (0.04-0.31/ 0.55) (0.04-0.39/ 0.47)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1DA10, ANT 18** Ø18 x 40

RF250R ANT 30
6GT2 821-5AC10, RS422 1-12/ 15 1-12/ 15
6GT2 821-5AC40, RS232 (ASCII) (0.04-0.47/ 0.59) (0.04-0.47/ 0.59)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1DD10, ANT 30 Ø30 x 40

RF260R
6GT2 821-6AC10, RS422
6GT2 821-6AC40, RS232 (ASCII)
6GT2 821-6AC32 / -6BC32, IO-Link* Integrated
75 x 75 x 41

RF280R
6GT2 821-8AC10, RS422 Integrated
6GT2 821-8AC40, RS232 (ASCII) 160 x 96 x 41

Accessories

* not with Tags D5xx


** antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
9 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D117 D127 D421 D521 D422 D522
RF200 Antennas
6GT2 600-0AG00 6GT2 600-0AF00 6GT2 600-4AE00 6GT2 600-5AE00 6GT2 600-4AF00 6GT2600-5AF00
112 byte EEPROM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 6GT2600-5AF00-0AX0
Family Matrix 8 kbyte FRAM

13.56 MHz
Passive Tags
Operational temperature range -40°C to 125°C -40°C to 125°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø4 x 5.2 Ø 6 x 5.8 Ø10 x 4.5 Ø10 x 4.5 Ø20 x 6 Ø20 x 6 ; Ø18 x 5.2
Ingress Protection (IP) rating IP68 IPx9K IP68/ IPx9K IP67/ IPx9K IP67/ IPx9K IP68 IP68

RF290R
6GT2 821-0AC12, RS232, RS422 ANT D1
Accessory:
Set for top rail mounting
6GT2 698-5AC00
6GK5798-8ML00-0AB3
75 x 75 x 20

ANT D5

6GT2 698-5AA10
380 x 380 x 110

ANT D6

6GT2 698-5AB00
580 x 480 x 110

ANT D10

6GT2 698-5AF00
1150 x 365 x 115

Covering hood for


ANT D6
(6GT2 690-0AD00)
Accessories

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
10 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D124 D324 D424 D524 D226s D426s D126 D426 D526
RF200 Antennas
6GT2 600-0AC10 6GT2 600-3AC00 6GT2 600-4AC00 6GT2 600-5AC00 6GT2 600-2BA00 6GT2 600-4BA00 6GT2 600-0AE00 6GT2 600-4AH00 6GT2 600-5AH00
112 byte EEPROM 992 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 316 byte EEPROM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM
Family Matrix 2000 byte FRAM

13.56 MHz
Passive Tags
Operational temperature range -40°C to 180°C -40°C to 140°C -40°C to 100°C -40°C to 100°C -40°C to 90°C -40°C to 90°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 30 x 3 Ø 30 x 3 Ø 50 x 3.6 Ø 50 x 3.6 Ø 50 x 3.6
Ingress Protection (IP) rating IP68/ IPx9K IP67/ IPx9K IP68 IP68 IP68
IP67 IP67/ IPx9K IP68 IP68

RF210R/ RF210M
6GT2 821-1AC10, RS422
6GT2 821-1AC32 / -1BC32, IO-Link*
Integrated 1-18/ 20 1-8/ 9 1-16/ 18 1-15/ 17 1-14/16 1-13/15
6GT2 823-0AA00, Handheld (RS422) (0.04-0.71/ 0.79) (0.04-0.31/ 0.35) (0.04-0.63/ 0.71) (0.04-0.59/ 0.67) (0.04-0,55/0,63) (0.04-0.51/0.59)
M18 x 71

RF220R
6GT2 821-2AC10, RS422
6GT2 821-2AC32 / -2BC32, IO-Link*
Integrated 1-28/ 31 2-21/ 25 2-25/ 29 2-22/ 25 1-25/30 1-25/30 2-30/ 35 2-25/ 30 2-25/ 30
(0.04-1.10/ 1.22) (0.08-0.83/ 0.98) (0.08-0.98/ 1.14) (0.08-0.87/ 0.98) (0.04-0.98/1.18) (0.04-0.98/1.18) (0.08-1.18/ 1.38) (0.08-0.98/ 1.18) (0.08-0.98/ 1.18)
M30 x 71

RF240R
6GT2 821-4AC10, RS422
6GT2 821-4AC40, RS232 (ASCII)
Integrated 2-53/ 60 1-36/ 40 (0.04- 1-47/ 53 (0.04- 1-45/ 55 1-40/48 1-40/48 2-57/ 65 2-45/ 55 2-45/ 55
6GT2821-4AC32 / -4BC32, IO-Link* (0.08-2.09/ 2.36) 1.42/ 1.57) 1.85/ 2.09) (0.04-1.77/ 2.17) (0.04-1.57/1.89) (0.04-1.57/1.89) (0.08-2.24/ 2.56) (0.08-1.77/ 2.17) (0.08-1.77/ 2.17)
50 x 50 x 30

RF250R ANT 1
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII) 2-60/ 75 5-60/ 70 2-70/ 80 1-65/ 80 2-60/72 2-60/72 2-80/ 95 2-80/ 95 2-80/ 95
6GT2821-5AC32 / -5BC32, IO-Link* (0.08-2.36/ 2.95) (0.20-2.36/ 2.76) (0.08-2.76/ 3.15) (0.04-2.56/ 3.15) (0.08-2.36/2.83) (0.08-2.36/2.83) (0.08-3.15/ 3.74) (0.08-3.15/ 3.74) (0.08/3.15/ 3.74)
6GT2 398-1CB00, ANT 1
75 x 75 x 20
RF250R ANT 3
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII) 2-32/ 40 2-22/ 35 1-34/ 48 1-35/ 40 1-30/38 1-30/38 1-47/ 60 1-44/ 58 2-35/ 45
6GT2821-5AC32 / -5BC32, IO-Link* (0.08-1.26/ 1.57) (0.08-0.87/ 1.38) (0.04-1.34/ 1.89) (0.04-1.38/ 1.57) (0.04-1.18/1.49) (0.04-1.18/1.49) (0.04-1.85/ 2.36) (0.04-1.73/ 2.28) (0.08-1.38/ 1.77)
6GT2 398-1CD40-0AX0, ANT 3
28 x 50 x 10
RF250R ANT 8
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CF10, ANT 8
28 x 50 x 10
RF250R ANT 12
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1DC10, ANT 12**
Ø8 x 38

Spacer Spacer Spacer Spacer Spacer Spacer Spacer


Accessories (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AL00) (6GT2 690-0AL00) (6GT2 690-0AL00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
11 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D124 D324 D424 D524 D226s D426s D126 D426 D526
RF200 Antennas
6GT2 600-0AC10 6GT2 600-3AC00 6GT2 600-4AC00 6GT2 600-5AC00 6GT2 600-2BA00 6GT2 600-4BA00 6GT2 600-0AE00 6GT2 600-4AH00 6GT2 600-5AH00
112 byte EEPROM 992 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 316 byte EEPROM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM
Family Matrix 2000 byte FRAM

13.56 MHz
Passive Tags
Operational temperature range -40°C to 180°C -40°C to 140°C -40°C to 100°C -40°C to 100°C -40°C to 90°C -40°C to 90°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 30 x 3 Ø 30 x 3 Ø 50 x 3.6 Ø 50 x 3.6 Ø 50 x 3.6
Ingress Protection (IP) rating IP68/ IPx9K IP67/ IPx9K IP68 IP68 IP68
IP67 IP67/ IPx9K IP68 IP68

RF250R ANT 18
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link* 1-24/ 37 1-18/ 27 1-27/ 36 1-25/ 30
6GT2 398-1DA10, ANT 18** (0.04-0.94/ 1.46) (0.04-0.71/ 1.06) (0.04-1.06/ 1.42) (0.04-0.98/ 1.18)
Ø18 x 40

RF250R ANT 30
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link* 1-35/ 48 1-22/ 35 1-34/ 48 1-35/ 40 1-47/ 60 1-44/ 58 2-44/ 50
6GT2 398-1DD10, ANT 30 (0.08-1.38/ 1.89) (0.04-0.87/ 1.38) (0.04-1.34/ 1.89) (0.04-1.38/ 1.57) (0.04-1.85/ 2.36) (0.04-1.73/ 2.28) (0.08-1.73/ 1.97)
Ø30 x 40

RF260R
6GT2 821-6AC10, RS422
6GT2 821-6AC40, RS232 (ASCII)
2-70/85 (0.08- 2-66/80 (0.08-
6GT2 821-6AC32 / -6BC32, IO-Link*
Integrated 2-80/ 85 2-60/ 70 2-60/ 70 2-60/ 70 2-75/ 100 2-70/ 85 2-70/ 85
(0.08-3.15/ 3.35) (0.08-2.36/ 2.76) (0.08-2.36/ 2.76) (0.08-2.36/ 2.76) 2.76/3.35) 2.59/3.15) (0.08-2.95/ 3.94) (0.08-2.76/ 3.35) (0.08-2.76/ 3.35)
75 x 75 x 41

Integrated
RF280R (0.08-
6GT2 821-8AC10, RS422
2-110/ 130 2-85/ 110 2-100/ 140 2-110/ 130 2-100/130 2-100/130 2-135/ 160 2-145/ 175 2-135/ 165
6GT2 821-8AC40, RS232 (ASCII) 160 x 96 x 41 (0.08-4.33/ 5.12) (0.08-3.35/ 4.33) (0.08-3.94/ 5.51) (0.08-4.33/ 5.12) 3.94/5.12) (0.08-3.94/5.12) (0.08-5.31/ 6.3) (0.08-5.71/ 6.89) (0.08-5.31/ 6.5)

Accessories

Spacer Spacer Spacer Spacer Spacer Spacer Spacer


(6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AL00) (6GT2 690-0AL00) (6GT2 690-0AL00)

* not with Tags D5xx


** antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
12 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D124 D324 D424 D524 D226s D426s D126 D426 D526
RF200 Antennas
6GT2 600-0AC10 6GT2 600-3AC00 6GT2 600-4AC00 6GT2 600-5AC00 6GT2 600-2BA00 6GT2 600-4BA00 6GT2 600-0AE00 6GT2 600-4AH00 6GT2 600-5AH00
112 byte EEPROM 992 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 316 byte EEPROM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM
Family Matrix 2000 byte FRAM

13.56 MHz
Passive Tags
Operational temperature range -40°C to 180°C -40°C to 140°C -40°C to 100°C -40°C to 100°C -40°C to 90°C -40°C to 90°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 30 x 3 Ø 30 x 3 Ø 50 x 3.6 Ø 50 x 3.6 Ø 50 x 3.6
Ingress Protection (IP) rating IP68/ IPx9K IP67/ IPx9K IP68 IP68 IP68
IP67 IP67/ IPx9K IP68 IP68

RF290R
6GT2 821-0AC12, RS232, RS422 ANT D1
Accessory: 1-100/ 140 1-90/ 130 1-90/ 130 1-90/ 130 2-90/130 (0.08- 2-90/130 (0.08- 5-110/150 5-100/ 140 5-100/ 140
Set for top rail mounting (0.04-3.94/ 5.51) (0.04-3.54/ 5.12) (0.04-3.54/ 5.12) (0.04-3.54/ 5.12) 3.54/5.12) 3.54/5.12) (0.20-4.34/ 5.91) (0.20-3.94/ 5.51) (0.20-3.94/ 5.51)
6GT2 698-5AC00
6GK5798-8ML00-0AB3
75 x 75 x 20

ANT D5

1-200/ 280 1-200/ 280 1-200/ 280 1-200/ 280 2-200/280 (0.08- 2-200/280 1-350/ 400 1-300/ 350 1-300/ 350
6GT2 698-5AA10 (0.04-7.87/ 11) (0.04-7.87/ 11) (0.04-7.87/ 11) (0.04-7.87/ 11) 7.87/11) (0.08-7.87/11) (0.04-13.78/ 15.75) (0.04-11.81/ 13.78) (0.04-11.81/ 13.78)
380 x 380 x 110

ANT D6

1-220/ 300 1-200/ 280 1-220/ 300 1-220/ 300 2-200/280 (0.08- 2-200/280 1-400/ 500 1-350/ 400 1-350/ 400
6GT2 698-5AB00 (0.04-8.66/ 11.81) (0.04-7.87/ 11) (0.04-8.66/ 11.81) (0.04-8.66/ 11.81) 7.87/11) (0.08-7.87/11) (0.04-15.75/ 19.69) (0.04-13.78/ 15.75) (0.04-13.78/ 15.75)
580 x 480 x 110

ANT D10
1-200/ 280 1-200/ 280 1-200/ 280 1-220/ 300 2-200/280 (0.08- 2-200/280 1-400/ 500 1-350/ 400 1-350/ 400
(0.04-7.87/ 11) (0.04-7.87/ 11) (0.04-7.87/ 11) (0.04-8.66/ 11.81) 7.87/11) (0.08-7.87/11) (0.04-15.75/ 19.69) (0.04-13.78/ 15.75) (0.04-13.78/ 15.75)
6GT2 698-5AF00
1150 x 365 x 115

Accessories
Covering hood
for ANT D6
(6GT2 690-0AD00)
Spacer Spacer Spacer Spacer Spacer Spacer Spacer
(6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AL00) (6GT2 690-0AL00) (6GT2 690-0AL00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
13 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D423 D425 D525 D428 D528 D139 D339
RF200 Antennas
6GT2 600-4AA00 6GT2 600-4AG00 6GT2 600-5AG00 6GT2 600-4AK00-0AX0 6GT2 600-5AK00 6GT2 600-0AA10 6GT2 600-3AA10
2 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 112 byte EEPROM 992 byte EEPROM
Family Matrix
13.56 MHz
Passive Tags
Operational temperature range -40°C to 100°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 220°C -40°C to 220°C
Dimensions (L x W x D) mm Ø 30 x 8 Ø 24 x 10 Ø 24 x 10 Ø 24 x 20 Ø 24 x 20 Ø 85 x 15 Ø 85 x 15
Ingress Protection (IP) rating IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/IPx9K IP68/IPx9K

RF210R/ RF210M
6GT2 821-1AC10, RS422
6GT2 821-1AC32 / -1BC32, IO-Link* Integrated 2-6/ 9 1-6/ 7 1-6/ 7 1-10/ 11 1-10/ 11
6GT2 823-0AA00, Handheld (RS422) (0,08-0.24/ 0.35) (0.04-0.24/ 0.28) (0.04-0.24/ 0.28) (0.04-0.39/ 0.43) (0.04-0.39/ 0.43)
M18 x 71

RF220R
6GT2 821-2AC10, RS422 2-16/ 20
6GT2 821-2AC32 / -2BC32, IO-Link* Integrated 1-11/ 13 1-11/ 13 1-18/ 21 1-15/ 20
(0,08-0.63/0.79) (0.04-0.43/ 0.51) (0.04-0.43/ 0.51) (0.04-0.71/ 0.83) (0.04-0.59/ 0.79)
M30 x 71

RF240R
6GT2 821-4AC10, RS422 1-30/ 34
6GT2 821-4AC40, RS232 (ASCII) Integrated 2-30/ 36 1-15/17 1-15/ 17 1-30/ 35
6GT2821-4AC32 / -4BC32, IO-Link* (0.08-1.18/ 1.42) (0.04-0.59/ 0.67) (0.04-0.59/ 0.67) (0.04-1.18/ 1.34) (0.04-1.18/ 1.38 )
50 x 50 x 30

RF250R ANT 1
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
2-42/ 52 2-25/ 30 2-25/ 30 2-40/ 50 2-40/ 45 5-90/ 105 2-85/ 100
6GT2821-5AC32 / -5BC32, IO-Link* (0.08-1.65/ 2.05) (0.08-0.98/ 1.18) (0.08-0.98/ 1.18) (0.08-1.57/ 1.97) (0.08-1.57/ 1.77) (0.2-3.54/ 4.13) (0.08-3.35/ 3.94)
6GT2 398-1CB00, ANT 1 75 x 75 x 20

RF250R ANT 3
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII) 1-24/ 30 1-12/ 20 1-12/ 20 1-20/ 32 1-20/ 25
6GT2821-5AC32 / -5BC32, IO-Link* (0.04-0.95/ 1.18) (0.04-0.47/ 0.79) (0.04-0.47/ 0.79) (0.04-0.79/ 1.26) (0.04-0.79/ 0.98)
6GT2 398-1CD40-0AX0, ANT 3 28 x 50 x 10
RF250R ANT 8
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2 821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CF10, ANT 8 Ø8 x 38

RF250R ANT 12
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII) 0-8/ 10 1-8/ 10 1-8/ 12 1-8/ 12
6GT2821-5AC32 / -5BC32, IO-Link* (0.0-0.31/ 0.39) (0.04-0.31/ 0.39) (0.04-0.31/ 0.47) (0.04-0.31/ 0.47)
Ø12 x 40
6GT2 398-1DC10, ANT 12**

Spacer Spacer
(6GT2 690-0AA00) (6GT2 690-0AA00)

Accessories Mounting cover Mount for quick tag Mount for quick tag
(6GT2 690-0AE00) exchange exchange
(6GT2 690-0AH00 - long) (6GT2 690-0AH00 - long)
(6GT2 690-0AH10 – short) (6GT2 690-0AH10 – short)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
14 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D423 D425 D525 D428 D528 D139 D339
RF200 Antennas
6GT2 600-4AA00 6GT2 600-4AG00 6GT2 600-5AG00 6GT2 600-4AK00-0AX0 6GT2 600-5AK00 6GT2 600-0AA10 6GT2600-3AA10
2 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 112 byte EEPROM 992 byte EEPROM
Family Matrix
13.56 MHz
Passive Tags
Operational temperature range -40°C to 100°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 220°C -40°C to 220°C
Dimensions (L x W x D) mm Ø 30 x 8 Ø 24 x 10 Ø 24 x 10 Ø 24 x 20 Ø 24 x 20 Ø 85 x 15 Ø 85 x 15
Ingress Protection (IP) rating IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/IPx9K IP68/IPx9K

RF250R ANT 18
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link* 1-16/ 20 1-11/ 16 1-11/ 16 1-18/ 25 1-15/ 20
6GT2 398-1DA10, ANT 18** (0.04-0.63/ 0.79) (0.04-0.43/ 0.63) (0.04-0.43/ 0.63) (0.04-0.71/ 0.98) (0.04-0.59/ 0.79)
Ø18 x 40

RF250R ANT 30
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link* 1-25 30 1-12/ 20 1-20/ 32 1-20/ 25
6GT2 398-1DD10, ANT 30 (0.04-0.98/ 1.18) (0.04-0.47/ 0.79) (0.04-0.79/ 1.26) (0.04-0.79/ 0.98)
Ø30 x 40

RF260R
6GT2 821-6AC10, RS422
6GT2 821-6AC40, RS232 (ASCII)
2-40/ 48 2-40/ 45 2-35/ 40 2-80/ 110 5-65/ 80
6GT2 821-6AC32 / -6BC32, IO-Link* Integrated
(0.08-1.57/ 1.89) (0.08-1.57/ 1.77) (0.08-1.38/ 1.57) (0.08-3.15/ 4.33) (0.20-2.56/ 3.15)
75 x 75 x 41

Integrated
RF280R 5-65/ 80 2-30/ 40 2-30/ 40 2-60/ 88 2-60/ 85 5-150/ 190 5-150/ 170
6GT2 821-8AC10, RS422
160 x 96 x 41 (0.20-2.36/ 2.76) (0.08-1.18/ 1.57) (0.08-1.18/ 1.57) (0.08-2.36/ 3.46) (0.08-2.36/ 3.35) (0.20-5.91/ 7.48) (0.20-5.91/ 6.69)
6GT2 821-8AC40, RS232 (ASCII)

Spacer Spacer
(6GT2 690-0AA00) (6GT2 690-0AA00)
Mounting cover Mount for quick tag Mount for quick tag
Accessories
(6GT2 690-0AE00) exchange exchange
(6GT2 690-0AH00 - long) (6GT2 690-0AH00 - long)
(6GT2 690-0AH10 – short) (6GT2 690-0AH10 – short)

* not with Tags D5xx


** antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
15 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


D423 D425 D525 D428 D528 D139 D339
RF200 Antennas
6GT2 600-4AA00 6GT2 600-4AG00 6GT2 600-5AG00 6GT2 600-4AK00-0AX0 6GT2 600-5AK00 6GT2 600-0AA10 6GT2 600-3AA10
2 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 112 byte EEPROM 992 byte EEPROM
Family Matrix
13.56 MHz
Passive Tags
Operational temperature range -40°C to 100°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 220°C -40°C to 220°C
Dimensions (L x W x D) mm Ø 30 x 8 Ø 24 x 10 Ø 24 x 10 Ø 24 x 20 Ø 24 x 20 Ø 85 x 15 Ø 85 x 15
Ingress Protection (IP) rating IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/IPx9K IP68/IPx9K

RF290R
6GT2 821-0AC12, RS232, RS422 ANT D1
Accessory: 10-60/85 1-55/ 80 1-55/ 80 5-160/ 220 5-130/170
Set for top rail mounting (0.39-2.36/ 3.35) (0.04-2.17/ 3.15) (0.04-2.17/ 3.15) (0.20-6.30/ 8.66) (0.20-5.12/ 6.69)
6GT2 698-5AC00
6GK5798-8ML00-0AB3
75 x 75 x 20

ANT D5

1-400/ 500 1-300/ 380


6GT2 698-5AA10 (0.04-15.75/ 19.69) (0.04-11.81/ 15.00)
380 x 380 x 110

ANT D6

1-500/ 600 1-400/ 480


6GT2 698-5AB00 (0.04-19.69/ 23.62) (0.04-15.75/ 18.9)
580 x 480 x 110

ANT D10
1-450/ 550 1-300/ 380
(0.04-17.72/ 21.65) (0.04-11.81/ 15.00)
6GT2 698-5AF00
1150 x 365 x 115

Covering hood for Spacer Spacer


(6GT2 690-0AA00) (6GT2 690-0AA00)
ANT D6
Mounting cover Mount for quick tag Mount for quick tag
Accessories (6GT2 690-0AD00)
(6GT2 690-0AE00) exchange exchange
(6GT2 690-0AH00 - long) (6GT2 690-0AH00 - long)
(6GT2 690-0AH10 – short) (6GT2 690-0AH10 – short)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
16 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF200
System Interfaces

17 Unrestricted | © Siemens 2023 | All rights reserved.


RF200 Reader Tags
System Interfaces powered through connection cable
D100 (6GT2 600-0AD10)
D200 (6GT2 600-1AD00 -0AX0)
D400 (6GT2 600-4AD00)

PROFINET & OPC UA & Ethernet/IP & TCP/IP D421 (6GT2 600-4AE00)
RF210R RF210M D521 (6GT2 600-5AE00)
(6GT2 821-1AC10) (6GT2 823-0AA00)

Communication Modules D422 (6GT2 600-4AF00)


A maximum of D522 (6GT2 600-5AF00)
D522 (6GT2 600-5AF00-0AX0)
1 reader at RF185C,
2 readers at RF186C/CI, RF220R
4 readers at RF188C/CI (6GT2 821-2AC10) D124 (6GT2 600-0AC10)
D324 (6GT2 600-3AC00)
of RF2x0R may be connected ANT 1 D424 (6GT2 600-4AC00)
(6GT2 398-1CB00) D524 (6GT2 600-5AC00)

RF185C RF186C RF188C ANT 3


(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40)
+ 2 m = 6GT2 891-4FH20
10 m = 6GT2 891-4FN10
5 m = 6GT2 891-4FH50
20 m = 6GT2 891-4FN20
+ RF240R
(6GT2 821-4AC10)
(6GT2 398-1CD40-0AX0)
ANT 8
D423 (6GT2 600-4AA00)

50 m = 6GT2 891-4FN50* (6GT2 398-1CF10)


ANT 12 D425 (6GT2 600-4AG00)

Additional IOs
Reader connector 90° angled:
2 m = 6GT2 891-4JH20
10 m = 6GT2 891-4JN10
5 m = 6GT2 891-4JH50
+ (6GT2398-1DC10

ANT 18
D525 (6GT2 600-5AG00)

RF250R (6GT2398-1DA10)
D226s (6GT2600-2BA00)
(6GT2 821-5AC10) D426s (6GT2600-4BA00)
ANT 30
(6GT2398-1DD10)

D127 (6GT2 600-4AF00)


Types of IO-Link D117 (6GT2 398-1CF00)

+ RF18xCI to sensor + 6ES7 14…..


IO module
IO-extension module
(up to 8xDI + 8xDO)
RF260R
(6GT2 821-6AC10) D428 (6GT2 600-4AK00-0AX0)
D528 (6GT2600-5AK00)
RF186CI RF188CI Sensor cable from
(6GT2 002-0JE50) (6GT2 002-0JE60) 0.5 to 15 m available See page 88 for detailed information
(e.g. 2 m = 6XV1801-2CH20)
D126 (6GT2 600-0AE00)
ANT D1 D426 (6GT2 600-4AH00)
RF280R (6GT2 698-5AC00) D526 (6GT2 600-5AH00)
(6GT2 821-8AC10)
ANT D5
(6GT2 698-5AA10)
Or one
D139 (6GT2 600-0AA10)
Standard sensor ANT D6
Or one
Actor
+ (6GT2 698-5AB00)
ANT D10
D339 (6GT2 600-3AA10)

(6GT2 698-5AF00) D160 (6GT2 600-0AB10)


D460 (6GT2 600-4AB00)
RF290R D560 (6GT2600-5AB00)
(6GT2 821-0AC12)

Opt. Splitter
w/ D5, D6 only D165 (6GT2 600-1AB00-0AX0) D261 (6GT2
(6GT2 690-0AC00) 600-1AA01-0AX0)

18 Unrestricted | © Siemens 2023 | All rights reserved. * Cable improper for RF290R usage due to length limitation of 20 m

SIMATIC Ident Configuration Guide


RF200 Reader Tags
System Interfaces powered through connection cable
D100 (6GT2 600-0AD10)
A maximum of 1 readers may be connected
+
D200 (6GT2 600-1AD00 -0AX0)
D400 (6GT2 600-4AD00)
RF120C to RF2x0R
SIMATIC PLC
+
2 m = 6GT2 091-4LH20 5 m = 6GT2 091-4LH50
10m = 6GT2 091-4LN10 RF210R D421 (6GT2 600-4AE00)
RF210M
S7-1200 And extension cables: (6GT2 821-1AC10) (6GT2 823-0AA00)
D521 (6GT2 600-5AE00)
RF120C 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
6GT2 002-0LA00
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
Up to 3 x RF120C modules per S7- D422 (6GT2 600-4AF00)
50 m = 6GT2 891-4FN50* D522 (6GT2 600-5AF00)
1200 rack 2 m = 6GT2 891-4JH20 Reader connector 90° angled D522 (6GT2 600-5AF00-0AX0)
5 m = 6GT2 891-4JH50 Reader connector 90° angled
10 m = 6GT2 891-4JN10 Reader connector 90° angled RF220R
(6GT2 821-2AC10) D124 (6GT2 600-0AC10)

SIMATIC PLC ANT 1


(6GT2 398-1CB00)
D324 (6GT2 600-3AC00)
D424 (6GT2 600-4AC00)
D524 (6GT2 600-5AC00)
A maximum of 2 readers may be connected
S7-300 Rack or
S7-400 via ET 200M
+ + ASM 475 to RF2x0R
2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50
+ RF240R
(6GT2 821-4AC10)
ANT 3
(6GT2 398-1CD40-0AX0)
ANT 8
D423 (6GT2 600-4AA00)

And extension cables: (6GT2 398-1CF10)


(DP-V1/PN-IO) ASM 475 + Front connector 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 ANT 12 D425 (6GT2 600-4AG00)
(6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0)
Accessories:
Connecting element (6ES7 390-5AA00-0AA0)
10 m = 6GT2 891-4FN10
50 m = 6GT2 891-4FN50*
20 m = 6GT2 891-4FN20

2 m = 6GT2 891-4JH20 Reader connector 90° angled


+ (6GT2398-1DC10

ANT 18
D525 (6GT2 600-5AG00)

Terminal element (6ES7 390-5BA00-0AA0) 5 m = 6GT2 891-4JH50 Reader connector 90° angled RF250R (6GT2398-1DA10)
10 m = 6GT2 891-4JN10 Reader connector 90° angled D226s (6GT2600-2BA00)
(6GT2 821-5AC10) D426s (6GT2600-4BA00)
ANT 30
(6GT2398-1DD10)
ET 200pro ET 200pro PROFIBUS DP-V1 D127
D117
(6GT2 600-4AF00)

Interface module (6GT2 398-1CF00)

via PROFIBUS ET 200pro PROFINET A maximum of 2 readers may be connected RF260R


or PROFINET Interface module
+ + RF170C to RF2x0R + (6GT2 821-6AC10) D428 (6GT2 600-4AK00-0AX0)
D528 (6GT2600-5AK00)

or S7 PLC ET 200pro PROFINET


CPU module RF170C
2 m = 6GT2 891-4FH20
10 m = 6GT2 891-4FN10
5 m = 6GT2 891-4FH50
20 m = 6GT2 891-4FN20
Communication module 50 m = 6GT2 891-4FN50* D126 (6GT2 600-0AE00)
Up to 9 x 170C ANT D1
(6GT2002-0HD01) D426 (6GT2 600-4AH00)
modules per Connection block Reader connector 90° angled RF280R (6GT2 698-5AC00) D526 (6GT2 600-5AH00)
ET 200pro rack 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 (6GT2 821-8AC10)
(6GT2002-1HD01) ANT D5
10 m = 6GT2 891-4JN10
(6GT2 698-5AA10)

PROFIBUS ANT D6 D139 (6GT2 600-0AA10)

A maximum of 2 readers may be connected + (6GT2 698-5AB00)


D339 (6GT2 600-3AA10)

+ RF166C to RF2x0R
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
+ ANT D10
(6GT2 698-5AF00) D160 (6GT2 600-0AB10)
D460 (6GT2 600-4AB00)
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 RF290R D560 (6GT2600-5AB00)
50 m = 6GT2 891-4FN50* (6GT2 821-0AC12)

RF166C (DP-V1) Reader connector 90° angled Opt. Splitter


Communication Module 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 w/ D5, D6 only D165 (6GT2 600-1AB00-0AX0) D261 (6GT2
(6GT2 002-0EE20) 10 m = 6GT2 891-4JN10 (6GT2 690-0AC00) 600-1AA01-0AX0)

19 Unrestricted | © Siemens 2023 | All rights reserved. * Cable improper for RF290R usage due to length limitation of 20 m

SIMATIC Ident Configuration Guide


RF200 Reader Tags
System Interfaces with external power supply at Y-cable
D100 (6GT2 600-0AD10)
ANT 1 D200 (6GT2 600-1AD00 -0AX0)
D400 (6GT2 600-4AD00)
(6GT2 398-1CB00)
RS232 / ASCII RF240R ANT 3
(6GT2 398-1CD40-0AX0) D421 (6GT2 600-4AE00)
(6GT2 821-4AC40) D521 (6GT2 600-5AE00)
ANT 8
(6GT2 398-1CF10)

1 Reader per COM port may be connected RF250R


+ ANT 12
(6GT2398-1DC10
D422 (6GT2 600-4AF00)
D522 (6GT2 600-5AF00)
D522 (6GT2 600-5AF00-0AX0)

Wide-Range power supply + 5 m cable


6GT2 898-0ACxx + 6GT2 491-1HH50 + RS 232 cable for RF2x0R
5 m = 6GT2 891-4KH50
+ (6GT2 821-5AC40) ANT 18
(6GT2398-1DA10) D124 (6GT2 600-0AC10)
D324 (6GT2 600-3AC00)

Extension cables: 5 m = 6GT2 891-4FH50


ANT 30 D424 (6GT2 600-4AC00)
D524 (6GT2 600-5AC00)
(6GT2398-1DD10)
10 m = 6GT2 891-4FN10

Simple text based protocol RF260R D423 (6GT2 600-4AA00)


(6GT2 821-6AC40)

D425 (6GT2 600-4AG00)


D525 (6GT2 600-5AG00)

RF280R
(6GT2 821-8AC40) D226s (6GT2600-2BA00)
D426s (6GT2600-4BA00)

RS232 Reader D127


D117
(6GT2 600-4AF00)
(6GT2 398-1CF00)

with external power supply at Y-cable


D428 (6GT2 600-4AK00-0AX0)
D528 (6GT2600-5AK00)

1 Reader per COM port may be connected ANT D1

Wide-Range power supply + 5 m cable


+ RS 232 cable for RF2x0R
5 m = 6GT2 891-4KH50
+ (6GT2 698-5AC00)

ANT D5
D126 (6GT2 600-0AE00)
D426 (6GT2 600-4AH00)
6GT2 898-0ACxx + 6GT2 491-1HH50 (6GT2 698-5AA10) D526 (6GT2 600-5AH00)
Extension cables: 5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10 ANT D6
RF290R

+
(6GT2 821-0AC12) (6GT2 698-5AB00)
Binary based protocol or Scanmode D139 (6GT2 600-0AA10)
ANT D10 D339 (6GT2 600-3AA10)
(6GT2 698-5AF00)

Opt. Splitter D160 (6GT2 600-0AB10)


D460 (6GT2 600-4AB00)
w/ D5, D6 only D560 (6GT2600-5AB00)
(6GT2 690-0AC00) optional antenna cables
10 m = 6GT2691-0CN10
7.2 m extension = 6GT2691-0DH72
D165 (6GT2 600-1AB00-0AX0) D261 (6GT2
*do not use with D10 ; do not use with Splitter 600-1AA01-0AX0)

20 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF200 Reader Tags
System Interfaces powered through connection cable
D100 (6GT2 600-0AD10)
D200 (6GT2 600-1AD00 -0AX0)
D400 (6GT2 600-4AD00)
IO-Link: S7-1200 A maximum of 4 (1*) readers may be connected
+ + S7-1200 to RF2x0R IO-Link
5 m = 6GT2 891-4LH50 (PUR) 5m=
+ D421 (6GT2 600-4AE00)
D521 (6GT2 600-5AE00)

SM1278 IO-Link 6GT2891-4LH50-0AX0 (PVC) RF210R IO-Link


S7-1200 (6ES7278-4BD32-0XB0) 10 m = 6GT2 891-4LN10 6GT2 821-1AC32 (8 Byte) D422 (6GT2 600-4AF00)
D522 (6GT2 600-5AF00)
6GT2 821-1BC32 (32 Byte) D522 (6GT2 600-5AF00-0AX0)

IO-Link: ET 200SP D124 (6GT2 600-0AC10)


D324 (6GT2 600-3AC00)
A maximum of 4 (1**) readers may be connected
via PROFIBUS
or PROFINET
+ + ET 200SP to RF2x0R IO-Link
5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10
+ RF220R IO-Link
D424 (6GT2 600-4AC00)
D524 (6GT2 600-5AC00)

ET 200SP head module Electronic module


6GT2 821-2AC32 (8 Byte)
or S7 PLC (6ES7 137-6BD00-0BA0)
6GT2 821-2BC32 (32 Byte) D423 (6GT2 600-4AA00)

D425 (6GT2 600-4AG00)


D525 (6GT2 600-5AG00)

IO-Link: ET 200AL A maximum of 4 readers may be connected


via PROFIBUS Head module IO-Link module
+ ET 200AL to RF2x0R IO-Link + RF240R IO-Link
6GT2 821-4AC32 (8 Byte)
6GT2 821-4BC32 (32 Byte)
D226s (6GT2600-2BA00)
D426s (6GT2600-4BA00)

or PROFINET PN: 6ES7-157-1AB00-0AB0


PB: 6ES7-157-1AA00-0AB0
(6ES7 147-5JD00-0BA0)
1.5 m = 3RK1902-4PB15-3AA0
5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10
D127 (6GT2 600-4AF00)
ANT 1 D117 (6GT2 398-1CF00)
(6GT2 398-1CB00)
ANT 3
(6GT2 398-1CD40-0AX0) D428 (6GT2 600-4AK00-0AX0)
ANT 8
IO-Link: ET 200pro (6GT2 398-1CF10)
D528 (6GT2600-5AK00)

ANT 12
via PROFIBUS (6GT2398-1DC10 D126 (6GT2 600-0AE00)
ET 200pro PROFIBUS DP-V1 RF250R
or PROFINET Interface module
ANT 18 D426 (6GT2 600-4AH00)
D526 (6GT2 600-5AH00)
IO-Link (6GT2398-1DA10)
or S7 PLC ET 200pro PROFINET A maximum of 4 (1*) readers may be connected 6GT2 821-5AC32
ANT 30
+ + +
(8 Byte)
Interface module 6GT2 821-5BC32 (6GT2398-1DD10)
ET 200AL to RF2x0R IO-Link (32 Byte)
D139 (6GT2 600-0AA10)
D339 (6GT2 600-3AA10)
ET 200pro PROFINET 1.5 m = 3RK1902-4PB15-3AA0
CPU module 5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10
Up to 9 x 170C D160 (6GT2 600-0AB10)
modules per IO-Link module D460 (6GT2 600-4AB00)
ET 200pro rack (6ES7147-4JD00-0AB0) D560 (6GT2600-5AB00)

RF260R IO-Link
*) for IO-Link reader of type 32 Byte: Some IO-Link Master permit only one or none reader per module 6GT2 821-6AC32 (8 Byte)
D165 (6GT2 600-1AB00-0AX0) D261 (6GT2
**) in case of using a PROFIBUS head module at ET 200SP, only one 32 Byte reader may be connected 6GT2 821-6BC32 (32 Byte) 600-1AA01-0AX0)

21 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF200 Reader Tags
System Interfaces powered through connection cable
D100 (6GT2 600-0AD10)
D200 (6GT2 600-1AD00 -0AX0)
D400 (6GT2 600-4AD00)
IO-Link: S7-1500
D421 (6GT2 600-4AE00)
A maximum of 8 (7*) readers may be connected
+ + S7-1500 to RF2x0R IO-Link
5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10
+ RF210R IO-Link
D521 (6GT2 600-5AE00)

CM 8xIO-Link, Electronic D422 (6GT2 600-4AF00)


S7-1500 6GT2 821-1AC32 (8 Byte)
D522 (6GT2 600-5AF00)
module 6GT2 821-1BC32 (32 Byte) D522 (6GT2 600-5AF00-0AX0)
(6ES7547-1JF00-0AB0)

D124 (6GT2 600-0AC10)


D324 (6GT2 600-3AC00)

IO-Link: PROFINET D424 (6GT2 600-4AC00)


D524 (6GT2 600-5AC00)

ET 200eco PN RF220R IO-Link


(6ES7148-6JA00-0AB0) 6GT2 821-2AC32 (8 Byte)
A maximum of 4 (0*) readers may be connected D423 (6GT2 600-4AA00)
OR 6GT2 821-2BC32 (32 Byte)

ET 200eco PN
(6ES7148-6JD00-0AB0) D425 (6GT2 600-4AG00)
A maximum of 4 readers may be connected D525 (6GT2 600-5AG00)
OR
ET 200eco PN CM 4x IO-Link, M12-L A maximum of 8 readers may be connected RF240R IO-Link
(6ES7148-6JE00-0BB0)

OR
+ Cables ET 200 eco PN to RF2x0R IO-Link + 6GT2 821-4AC32 (8 Byte)
6GT2 821-4BC32 (32 Byte)
D226s (6GT2600-2BA00)
D426s (6GT2600-4BA00)

1.5 m = 3RK1902-4PB15-3AA0
D127 (6GT2 600-4AF00)
ET 200eco PN CM 8x IO-Link, M12-L 5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10 ANT 1 D117 (6GT2 398-1CF00)
(6ES7148-6JG00-0BB0) (6GT2 398-1CB00)
(6ES7148-6JJ00-0BB0) ANT 3
(6GT2 398-1CD40-0AX0) D428 (6GT2 600-4AK00-0AX0)
ANT 8
IO-Link: (6GT2 398-1CF10)
D528 (6GT2600-5AK00)

ANT 12
Other Master (6GT2398-1DC10 D126 (6GT2 600-0AE00)
RF250R ANT 18 D426 (6GT2 600-4AH00)
D526 (6GT2 600-5AH00)
IO-Link (6GT2398-1DA10)
M12 Cables for IP65 Masters 6GT2 821-5AC32
ANT 30
+ 5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10

Open end Cables for IP20 Masters + (8 Byte)


6GT2 821-5BC32
(32 Byte)
(6GT2398-1DD10)
D139 (6GT2 600-0AA10)
D339 (6GT2 600-3AA10)
5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10

D160 (6GT2 600-0AB10)


D460 (6GT2 600-4AB00)
D560 (6GT2600-5AB00)

According to www.io-link.com *) for IO-Link reader of type 32 Byte: RF260R IO-Link


see competency-matrix for all available offers Reduced number of reader per module for some types of IO-Link Master 6GT2 821-6AC32 (8 Byte)
D165 (6GT2 600-1AB00-0AX0) D261 (6GT2
6GT2 821-6BC32 (32 Byte) 600-1AA01-0AX0)

22 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF300
Family Matrix
13.56 MHz – passive tags

23 Unrestricted | © Siemens 2023 | All rights reserved.


RF300 Antennas Suitable for
Dynamic
RF320T RF330T RF340T RF350T RF360T RF370T RF380T
6GT2 800-1CA00 6GT2 800-5BA00 20 byte EEPROM + 6GT2 800-5BD00 20 byte EEPROM + 20 Byte EEPROM + 6GT2 800-5DA00
Family Matrix Operation 20 byte 20 byte EEPROM 6GT2 800-4BB00 20 byte EEPROM 6GT2 800-4AC00 6GT2 800-5BE00 20 byte EEPROM
EEPROM 32 kbyte FRAM 8 kbyte FRAM 32 kbyte FRAM 8 kbyte FRAM 32 kbyte FRAM 32 kbyte FRAM
(RF300 Tags) 6GT2 800-5BB00
32 kByte FRAM
6GT2 800-5AC00
32 kbyte FRAM
6GT2 800-6BE00
64 kbyte FRAM

13.56 MHz
Passive Tags
-40°C to 140°C -40°C to 100°C -40°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 85°C --40°C to 220°C
Operational temperature range Ø 27 x 4 Ø 30 x 8 48 x 25 x 15 50 x 50 x 20 85.8 x 54.1 x 2.5 75 x 75 x 41 Ø 114 x 83
Dimensions (L x W x D) mm
IP67/IPX9K IP68/IPX9K IP67/IPX9K IP68 IP67 IP68 IP68
Ingress Protection (IP) rating

RF310R
RS422
1-23/ 26 2-18/ 21 2-36/ 41 2-47/ 53 2-60/68 2-45/ 60
6GT2 801-1BA10 Integrated YES
6GT2 801-1BA10-0AX1 (90°plate) (0.04-0.91/ 1.02) (0.08-0.71/ 0.83) (0.08-1.42/ 1.61) (0.08-1.85/ 2.09) (0.08-2.36/ 2.68) (0.08-1.77./ 2.36)
55 x 75 x 30
6GT2 801-1BA10-0AX2 (Ex)
6GT2 801-1BA20-0AX1 (Scanmode)
RF340R
RS422
1-20/ 25 2-20/ 24 2-50/ 60 2-60/ 75 2-65/ 85 5-60/ 80 5-80/ 100
6GT2 801-2BA10 Integrated YES
6GT2 801-2BA10-0AX2 (Ex) (0.04-0.79/ 0.98) (0.08-0.79/ 0.91) (0.08-1.97/ 2.28) (0.08-2.36/ 2.95) (0.08-2.56/ 3.35) (0.20-2.36/ 3.15) (0.20-3.15/ 3.94)
75 x 75 x 41

RF350R ANT 1
RS422
1-30/ 40 2-25/ 30 2-55/ 70 2-65/ 85 2-75/ 100 5-65/ 85 5-90/ 110
6GT2 801-4BA10 YES
6GT2 801-4BA10-0AX2 (Ex) (0.04-1.18/ 1.46) (0.08-0.98/ 1.18) (0.08-2.16/ 2.76) (0.08-2,56/ 3.35) (0.08-2.95./ 3.94) (0.20-2.56/ 3.35) (0.20-3.54/ 4.33)
6GT2 398-1CB00 (ANT 1) 75 x 75 x 20

RF350R ANT 3
RS422
1-16 / 20 1-16 / 20 2-32/ 40 2-35/ 42
6GT2 801-4BA10 NO
6GT2 801-4BA10-0AX2 (Ex) (0.04-0.59/ 0.71) (0.04-0.63/ 0.79) (0.08-1.26/ 1.57) (0.08-1.38/ 1.65)
6GT2 398-1CD40-0AX0 (ANT 3) 28 x 50 x 10

RF350R ANT 8
RS422
NO
6GT2 398-1CF10
6GT2 398-1CF00 Ø8 x 38

Holder:
20 mm spacer (short: 6GT2 090-0QA00)
(6GT2 190-0AA00) (long: 6GT2 090-0QA00-0AX3)
Accessories Spacer Mounting cover Cover for holder:
(6GT2 690-0AK00) (6GT2 690-0AE00)
Fixing pocket (6GT2 090-0QB00)
(6GT2 190-0AB00) All Purpose Support
(6GT2 590-0QA00)

* antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC00 (ANT12) or 6GT2398-1DA00 (ANT18)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
24 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas Suitable for
Dynamic
RF320T RF330T RF340T RF350T RF360T RF370T RF380T
6GT2 800-1CA00 6GT2 800-5BA00 20 byte EEPROM + 6GT2 800-5BD00 20 byte EEPROM + 20 Byte EEPROM + 6GT2 800-5DA00
Family Matrix Operation 20 byte 20 byte EEPROM 6GT2 800-4BB00 20 byte EEPROM 6GT2 800-4AC00 6GT2 800-5BE00 20 byte EEPROM
EEPROM 32 kbyte FRAM 8 kbyte FRAM 32 kbyte FRAM 8 kbyte FRAM 32 kbyte FRAM 32 kbyte FRAM
(RF300 Tags) 6GT2 800-5BB00
32 kByte FRAM
6GT2 800-5AC00
32 kbyte FRAM
6GT2 800-6BE00
64 kbyte FRAM

13.56 MHz
Passive Tags
-40°C to 140°C -40°C to 100°C -40°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 85°C --40°C to 220°C
Operational temperature range Ø 27 x 4 Ø 30 x 8 48 x 25 x 15 50 x 50 x 20 85.8 x 54.1 x 2.5 75 x 75 x 41 Ø 114 x 83
Dimensions (L x W x D) mm
IP67/IPX9K IP68/IPX9K IP67/IPX9K IP68 IP67 IP68 IP68
Ingress Protection (IP) rating

RF350R ANT 12
RS422

6GT2 801-4BA10 NO
6GT2 801-4BA10-0AX2 (Ex)
6GT2 398-1DC10 (ANT 12) *)
Ø12 x 40

RF350R ANT 18
RS422
1-10/ 13 1-11/ 13 1-18/ 22
6GT2 801-4BA10 NO
6GT2 801-4BA10-0AX2 (Ex) (0.04-0.39/ 0.51) (0.04-0.43/ 0.51) (0.04-0.71/ 0.87)
6GT2 398-1DA10 (ANT 18) *) Ø18 x 40

RF350R ANT 30
RS422
1-15/ 20 2-15/ 18 1-25/ 30 0-35/ 40 2-32/ 38
6GT2 801-4BA10 NO
6GT2 801-4BA10-0AX2 (Ex) (0.04-0.59/ 0.79) (0.08-0.59/ 0.71) (0.04-0.98/ 1.1 8) (0-1.18/ 1.57) (0.08-1.26/ 1.5)
6GT2 398-1DD10 (ANT 30) Ø30 x 40

RF360R
Ethernet
Integrated 1-20/ 25 2-18/ 23 2-50/ 58 2-60/ 75 2-65/ 85 5-60/ 80 5-80/ 100
6GT2 801-5BA30 YES
141 x 80 x 42 (0.04-0.79/ 0.98) (0.08-0.71/ 0.91) (0.04-1.97/ 2.28) (0.08-2.36/ 2.95) (0.08-2.56/ 3.35) (0.20-2.36/ 3.15) (0.20-3.15/ 3.94)

RF380R
RS422, RS232
Integrated 2-45/ 60 5-45/ 48 2-80/ 105 2-100/ 125 2-120/ 150 5-100/ 135 5-125/ 160
6GT2 801-3BA10 YES
160 x 96 x 41 (0.08-1.77/ 2.36) (0.2-1.77/ 1.89) (0.08-3.15/ 4.13) (0.08-3.94/ 4.92) (0.08-4.72/ 5.91) (0.20-3.94/ 5.31) (0.20-4.92/ 6.30)
6GT2 801-3BA10-0AX2 (Ex)

Holder:
20 mm spacer (short: 6GT2 090-0QA00)
(6GT2 190-0AA00) (long: 6GT2 090-0QA00-0AX3)
Accessories Spacer Mounting cover Cover for holder:
(6GT2 690-0AK00) (6GT2 690-0AE00)
Fixing pocket (6GT2 090-0QB00)
(6GT2 190-0AB00) All Purpose Support
(6GT2 590-0QA00)

* antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC00 (ANT12) or 6GT2398-1DA00 (ANT18)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
25 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas
D165 D261 D100 D200 D400 D160 D460
Family Matrix 6GT2 600-1AB00-0AX0
112 byte EEPROM
6GT2 600-1AA01-0AX0
316 byte EEPROM
6GT2 600-0AD10
112 byte EEPROM
6GT2 600-1AD00 -0AX0
256 byte EEPROM
6GT2 600-4AD00
2 kbyte FRAM
6GT2 600-0AB10
112 byte EEPROM
6GT2 600-4AB00
2 kbyte FRAM
(ISO Tags)
13.56 MHz
Passive Tags
-25°C to 85°C -25°C to 85°C -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 175°C -40°C to 100°C
Operational temperature range 86 x 54 x 0.3 55 x 55 x 0.3 Ø 16 x 3 Ø 16 x 3
85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8
Dimensions (L x W x D) mm
Ingress Protection (IP) rating
IP65 IP65 IP68 IP67 IP67 IP68/IPx9K IP67/IPx9K

RF310R
RS422
6GT2 801-1BA10 2-90/ 102 2-74/ 83 2-93/ 105 2-80/ 90 2-104/ 115 1-39/ 44 1-32/ 38
Integrated
6GT2 801-1BA10-0AX1 (90°plate) (0.08-3.54/ 4.02) (0.08-2.91/ 3.27) (0.08-3.66/ 4.1) (0.08-3.15/ 3.54) (0.08-4.09/ 4.53) (0.04-1.54/ 1.73) (0.08-1.26/ 1.50)
6GT2 801-1BA10-0AX2 (Ex)
6GT2 801-1BA20-0AX1 (Scanmode)

RF340R
RS422 15-120/ 140 40-100/ 120 5-110/ 140 10-100/ 115 2-100/ 130 2-35/ 60 2-25/ 40
Integrated
6GT2 801-2BA10 (0.59-4.72/ 5.51) (1.57-3.93/ 4.72) (0.20-4.33/ 5.51) (0.39-3.94/ 4.53) (0.08-3.93/ 5.12) (0.08-1.38/ 2.36) (0.08-0.98/ 1.57)
6GT2 801-2BA10-0AX2 (Ex)

RF350R ANT 1
RS422 5-100/ 120 5-80/ 95 5-110/ 140 5-95/ 115 2-110/ 135 2-35/ 60 2-32/ 38
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.20-3.94/ 4.72) (0.20-3.15/ 3.74) (0.20-4.33/ 5.51) (0.20-3.74/ 4.53) (0.08-4.33/ 5.31) (0.08-1.38/ 2.36) (0.08-1.26/ 1.50)
6GT2 398-1CB00 (ANT 1)
75 x 75 x 20

RF350R ANT 3
RS422 1-28/ 35 1-20/ 28
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.04-1.10/ 1.38) (0.04-0.79/ 1.10)
6GT2 398-1CD40-0AX0 (ANT 3)
28 x 50 x 10

RF350R ANT 8
RS422

6GT2 398-1CF10 Ø8 x 38
6GT2 398-1CF00

Holder Holder Holder


(6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 390-0AA00)
Spacer Spacer
20 mm spacer 20 mm spacer 20 mm spacer (6GT2 690-0AG00) (6GT2 690-0AG00)
Accessories (6GT2 190-0AA00) (6GT2 190-0AA00)
(6GT2 190-0AA00) Angle pattern body Angle pattern body
(6GT2690-0AN00) (6GT2690-0AN00)
Fixing pocket Fixing pocket Fixing pocket
(6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2 190-0AB00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
26 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas
D165 D261 D100 D200 D400 D160 D460
Family Matrix 6GT2 600-1AB00-0AX0
112 byte EEPROM
6GT2 600-1AA01-0AX0
316 byte EEPROM
6GT2 600-0AD10
112 byte EEPROM
6GT2 600-1AD00 -0AX0
256 byte EEPROM
6GT2 600-4AD00
2 kbyte FRAM
6GT2 600-0AB10
112 byte EEPROM
6GT2 600-4AB00
2 kbyte FRAM
(ISO Tags)
13.56 MHz
Passive Tags
-25°C to 85°C -25°C to 85°C -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 175°C -40°C to 100°C
Operational temperature range 86 x 54 x 0.3 55 x 55 x 0.3 Ø 16 x 3 Ø 16 x 3
85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8
Dimensions (L x W x D) mm
Ingress Protection (IP) rating
IP65 IP65 IP68 IP67 IP67 IP68/IPx9K IP67/IPx9K

RF350R ANT 12
RS422 0-8/ 12 1-8/ 10
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0-0.31/ 0.47) (0.04-0.31/ 0.39)
6GT2 398-1DC10 (ANT 12) *) Ø12 x 40

RF350R ANT 18
RS422 1-18/ 20 1-12/ 16
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.04-0.71/ 0.79) (0.04-0.47/ 0.63)
6GT2 398-1DA10 (ANT 18) *) Ø18 x 40

RF350R ANT 30
RS422 1-24/ 28 1-18/ 20
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.04-0.94/ 1.10) (0.04-0.71/ 0.79)
6GT2 398-1DD10 (ANT 30) Ø30 x 40

RF360R
Ethernet
Integrated 5-110/ 140 10-100/ 115 2-100/ 125
6GT2 801-5BA30 141 x 80 x 42 (0.20-4.33/ 5.51) (0.39-3.94/ 4.5pass3) (0.08-3.94/ 4.92)

RF380R
RS422, RS232
Integrated 10-170/ 200 20-120/ 160 10-170/ 210 20-150/195 10-165/ 185 2-64/ 80 2-65/ 90
6GT2 801-3BA10 160 x 96 x 41 (0.39-6.69/ 7.87) (0.79-4.72/ 6.30) (0.39-6.69/ 8.27) (0.79-5.90/ 7.67) (0.39-4.50/ 7.28) (0.08-2.52/ 3.15) (0.08-2.56/ 3.54)
6GT2 801-3BA10-0AX2 (Ex)

RF382R
RS422, RS232 Integrated 35-50/ 65 35-50/ 60
160 x 96 x 41 (1.38-1.97/ 2.56) (1.38-1.97/ 2.36)
6GT2 801-3AB20-0AX0

Holder Holder Holder


(6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 390-0AA00)
Spacer Spacer
20 mm spacer 20 mm spacer 20 mm spacer (6GT2 690-0AG00) (6GT2 690-0AG00)
Accessories (6GT2 190-0AA00) (6GT2 190-0AA00)
(6GT2 190-0AA00) Angle pattern body Angle pattern body
(6GT2690-0AN00) (6GT2690-0AN00)
Fixing pocket Fixing pocket Fixing pocket
(6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2 190-0AB00)

* antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC00 (ANT12) or 6GT2398-1DA00 (ANT18)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
27 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas
D117 D127 D421 D422 D124 D324 D424
Family Matrix 6GT2 600-0AG00
112 byte EEPROM
6GT2 600-0AF00
112 byte EEPROM
6GT2 600-4AE00
2 kbyte FRAM
6GT2 600-4AF00
2 kbyte FRAM
6GT2 600-0AC10
112 byte EEPROM
6GT2 600-3AC00
992 byte EEPROM
6GT2 600-4AC00
2 kbyte FRAM
(ISO Tags)
13.56 MHz
Passive Tags
-40°C to 125°C -40°C to 180°C -40°C to 140°C -40°C to 100°C
-40°C to 125°C -40°C to 100°C -40°C to 100°C
Ø4 x 5.2 Ø10 x 4.5 Ø 27 x 4 Ø 27 x 4 Ø 27 x 4
Operational temperature range Ø 6 x 5.8 Ø20 x 6
Dimensions (L x W x D) mm IP68 IPx9K IP67/ IPx9K IP68/ IPx9K IP67 IP67/ IPx9K
IP68/ IPx9K IP68
Ingress Protection (IP) rating

RF310R
RS422
6GT2 801-1BA10 2-64/ 72 2-64/ 72 1-68/ 75
Integrated
6GT2 801-1BA10-0AX1 (90°plate) (0.08-2.52/ 2.83) (0.08-2.52/ 2.83) (0.04-2.68/ 2.95)
6GT2 801-1BA10-0AX2 (Ex) 55 x 75 x 30
6GT2 801-1BA20-0AX1 (Scanmode)

RF340R
RS422 2-60/ 75 2-55/ 70 2-55/ 70
Integrated
6GT2 801-2BA10 (0.08-2.36/ 2.95) (0.08-2.17/ 2.76) (0.08-2.17/ 2.76)
75 x 75 x 41
6GT2 801-2BA10-0AX2 (Ex)

RF350R ANT 1
RS422 2-65/ 85 2-66/ 78 2-75/ 88
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.08-2.56/ 3.35) (0.08-2.60/ 3.07) (0.08-2.95/ 3.46)
6GT2 398-1CB00 (ANT 1) 75 x 75 x 20

RF350R ANT 3
RS422
1-11/18 1-35/ 42 1-22/ 32 1-40/ 48
6GT2 801-4BA10
(0.04-0.43/ 0.71) (0.04-1.38/ 1.65) (0-0.04/ 1.26) (0.04-1.57/ 1.89)
6GT2 801-4BA10-0AX2 (Ex)
6GT2 398-1CD40-0AX0 (ANT 3) 28 x 50 x 10

RF350R ANT 8
RS422 0-4/5 0-4/5 0-3/4
(0.0-0.16/0.19) (0.0-0.16/0.19) (0.0-0.12/0.16)
6GT2 398-1CF10 Ø8 x 38
6GT2 398-1CF00

Spacer Spacer Spacer


Accessories (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
28 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas
D117 D127 D421 D422 D124 D324 D424
Family Matrix 6GT2 600-0AG00
112 byte EEPROM
6GT2 600-0AF00
112 byte EEPROM
6GT2 600-4AE00
2 kbyte FRAM
6GT2 600-4AF00
2 kbyte FRAM
6GT2 600-0AC10
112 byte EEPROM
6GT2 600-3AC00
992 byte EEPROM
6GT2 600-4AC00
2 kbyte FRAM
(ISO Tags)
13.56 MHz
Passive Tags
-40°C to 125°C -40°C to 180°C -40°C to 140°C -40°C to 100°C
-40°C to 125°C -40°C to 100°C -40°C to 100°C
Ø4 x 5.2 Ø10 x 4.5 Ø 27 x 4 Ø 27 x 4 Ø 27 x 4
Operational temperature range Ø 6 x 5.8 Ø20 x 6
Dimensions (L x W x D) mm IP68 IPx9K IP67/ IPx9K IP68/ IPx9K IP67 IP67/ IPx9K
IP68/ IPx9K IP68
Ingress Protection (IP) rating

RF350R ANT 12
RS422 0-2/ 3 0-3/ 4 0-3/ 5
6GT2 801-4BA10
(0.0-0.08/ 0.12) (0-0.12/ 0.16) (0-0.12/ 0.20)
6GT2 801-4BA10-0AX2 (Ex)
6GT2 398-1DC10 (ANT 12) *) Ø12 x 40

RF350R ANT 18
RS422 0-5/ 6 0-5/ 6 0-4/ 6 1-10/ 13 2-24/ 28 1-22/ 28 1-27/ 35
6GT2 801-4BA10
(0.-0.20/ 0.24) (0.-0.20/ 0.24) (0-0.24/ 0.31) (0.04-0.39/ 0.51) (0.08-0.94/ 1.10) (0.04-0.87/ 1.1) (0.04-1.06/ 1.38)
6GT2 801-4BA10-0AX2 (Ex)
Ø18 x 40
6GT2 398-1DA10 (ANT 18) *)

RF350R ANT 30
RS422 1-14/ 16 1-35/ 40 1-35/ 40 1-45/ 50
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.04-0.55/ 0.63) (0.04-1.38/ 1.57) (0.04-1.38/ 1.57) (0.04-1.77/ 1.97)
6GT2 398-1DD10 (ANT 30) Ø30 x 40

RF360R
Ethernet
Integrated 2-60/ 75 2-55/ 70 2-55/ 70
6GT2 801-5BA30 141 x 80 x 42 (0.08-2.36/ 2.95) (0.08-2.17/ 2.76) (0.08-2.17/ 2.76)

RF380R
RS422, RS232
Integrated 1-120/ 140 2-96/ 120 2-120/ 140
6GT2 801-3BA10 160 x 96 x 41 (0.04-4.72/ 5.51) (0.08-3.78/ 4.72) (0.08-4.72/ 5.51)
6GT2 801-3BA10-0AX2 (Ex)

RF382R
RS422, RS232 Integrated 40-65/ 75 40-65/ 75 40-65/ 75
160 x 96 x 41 (1.57-2.56/ 2.95) (1.57-2.56/ 2.95) (1.57-2.56/ 2.95)
6GT2 801-3AB20-0AX0

Spacer Spacer Spacer


Accessories (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00)

* antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC00 (ANT12) or 6GT2398-1DA00 (ANT18)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
29 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas
D126 D426 D423 D425 D428 D139 D339
Family Matrix 6GT2 600-0AE00 6GT2 600-4AH00
2 kbyte FRAM
6GT2 600-4AA00
2 kbyte FRAM
6GT2 600-4AG00
2 kbyte FRAM
6GT2 600-4AK00-0AX0
2 kbyte FRAM
6GT2 600-0AA10
112 byte EEPROM
6GT2600-3AA10
992 byte EEPROM
112 byte EEPROM
(ISO Tags)
13.56 MHz
Passive Tags
-40°C to 100°C -40°C to 100°C -40°C to 125°C -40°C to 125°C -40°C to 220°C -40°C to 220°C
-40°C to 100°C
Operational temperature range Ø 50 x 3.6 Ø 50 x 3.6 Ø 24 x 10 Ø 24 x 20 Ø 85 x 15 Ø 85 x 15
Ø 30 x 8
Dimensions (L x W x D) mm IP68 IP68 IP68/ IPx9K IP68/ IPx9K IP68/IPx9K IP68/IPx9K
IP68/ IPx9K
Ingress Protection (IP) rating

RF310R
RS422
6GT2 801-1BA10 2-65/ 73 5-75/ 90 2-35/ 46 1-22/ 25 1-40/ 45 5-96/ 109 5-74/ 84
Integrated
6GT2 801-1BA10-0AX1 (90°plate) (0.08-2.56/ 2.87) (0.2-2.95/ 3.54) (0.08-1.38/ 1.81) (0.04-0.87/ 0.98) (0.08-1.57/ 1.77) (0.20-3.78/ 4.29) (0.20-2.91/ 3.31)
6GT2 801-1BA10-0AX2 (Ex) 55 x 75 x 30
6GT2 801-1BA20-0AX1 (Scanmode)

RF340R
RS422 2-85/ 110 1-80/ 100 5-40/ 48 2-20/ 30 2-40/ 50 5-80/ 110 5-75/ 85
Integrated
6GT2 801-2BA10 (0.08-3.34/ 4.33) (0.04-3.15/ 3.94) (0.2-1.57/ 1.89) (0.08-0.79/ 1.18) (0.08-1.57/ 1.97) (0.20-3.15/ 4.33) (0.20-2.95/ 3.35)
75 x 75 x 41
6GT2 801-2BA10-0AX2 (Ex)

RF350R ANT 1
RS422 2-90/ 120 2-85/ 95 10-48/ 60 2-23/ 32 2-40/ 50 5-85/ 115 5-90/ 105
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.08-3.54/ 4.72) (0.08-3.35/ 3.74) (0.39-1.89/ 2.36) (0.08-0.91/ 1.26) (0.08-1.57/ 1.97) (0.20-3.35/ 4.53) (0.20-3.54/ 4.13)
6GT2 398-1CB00 (ANT 1) 75 x 75 x 20

RF350R ANT 3
RS422 5-20/ 30 2-18/ 22 2-28/ 30
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.2-0.79/ 1.18) (0.08-0.71/ 0.87) (0.08-1.10/ 1.18)
6GT2 398-1CD40-0AX0 (ANT 3) 28 x 50 x 10

RF350R ANT 8
RS422

6GT2 398-1CF10 Ø8 x 38
6GT2 398-1CF00

Spacer
(6GT2 690-0AA00)
Spacer Spacer Mounting cover
Accessories (6GT2 690-0AL00) (6GT2 690-0AL00) (6GT2 690-0AE00) Mount for quick tag exchange
(6GT2 690-0AH00 - long)
(6GT2 690-0AH10 – short)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
30 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas
D126 D426 D423 D425 D428 D139 D339
Family Matrix 6GT2 600-0AE00 6GT2 600-4AH00
2 kbyte FRAM
6GT2 600-4AA00
2 kbyte FRAM
6GT2 600-4AG00
2 kbyte FRAM
6GT2 600-4AK00-0AX0
2 kbyte FRAM
6GT2 600-0AA10
112 byte EEPROM
6GT2 600-3AA10
992 byte EEPROM
112 byte EEPROM
(ISO Tags)
13.56 MHz
Passive Tags
-40°C to 100°C -40°C to 100°C -40°C to 125°C -40°C to 125°C -40°C to 220°C -40°C to 220°C
-40°C to 100°C
Operational temperature range Ø 50 x 3.6 Ø 50 x 3.6 Ø 24 x 10 Ø 24 x 20 Ø 85 x 15 Ø 85 x 15
Ø 30 x 8
Dimensions (L x W x D) mm IP68 IP68 IP68/ IPx9K IP68/ IPx9K IP68/IPx9K IP68/IPx9K
IP68/ IPx9K
Ingress Protection (IP) rating

RF350R ANT 12
RS422 1-10/ 17
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.04-0.39/ 0.67)
6GT2 398-1DC10 (ANT 12) *) Ø12 x 40

RF350R ANT 18
RS422 1-10/ 14 1-15/ 20
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.04-0.39/ 0.55) (0.04-0.59/ 0.79)
Ø18 x 40
6GT2 398-1DA10 (ANT 18) *)

RF350R ANT 30
RS422 1-42/ 50 1-45/ 48 5-22/ 28 1-15/ 20 1-25/ 28
6GT2 801-4BA10
(0-1.65/ 1.97) (0.04-1.77/ 1.89) (0.2-0.87/ 1.10) (0.04-0.59/ 0.79) (0.04-0.98/ 1.10)
6GT2 801-4BA10-0AX2 (Ex)
6GT2 398-1DD10 (ANT 30) Ø30 x 40

RF360R
Ethernet
Integrated 2-85/ 110 1-80/ 100 5-42/ 50 5-80/ 110 5-75/ 85
6GT2 801-5BA30 141 x 80 x 42 (0.08-3.35/ 4.33) (0.04-3.15/ 3.94) (0.2-1.65/1.97) (0.2-3.15/ 4.33) (0.2-2.95/ 3.35)

RF380R
RS422, RS232
Integrated 2-145/ 190 2-155/ 195 5-75/ /83 2-35/ 50 2-70/ 95 5-200/ 230 17-160/ 180
6GT2 801-3BA10 160 x 96 x 41 (0.08-5.71/ 7.48) (0.08-6.1/ 7.68) (0.2-2.95/ 3.27) (0.08-1.38/ 1.97) (0.08-2.76/ 3.74) (0.20-7.87/ 9.05) (0.67-6.30/ 7.09)
6GT2 801-3BA10-0AX2 (Ex)

RF382R
RS422, RS232 Integrated
160 x 96 x 41
6GT2 801-3AB20-0AX0

Spacer
(6GT2 690-0AA00)
Spacer Spacer Mounting cover
Accessories (6GT2 690-0AL00) (6GT2 690-0AL00) (6GT2 690-0AE00) Mount for quick tag exchange
(6GT2 690-0AH00 - long)
(6GT2 690-0AH10 – short)

* antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC00 (ANT12) or 6GT2398-1DA00 (ANT18)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
31 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas
D521 D522 D524 D525 D526 D528 D560
Family Matrix 6GT2 600-5AE00
8 kByte FRAM
6GT2 600-5AF00
8 kByte FRAM
6GT2 600-5AC00
8 kByte FRAM
6GT2 600-5AG00
8 kbyte FRAM
6GT2 600-5AH00
8 kByte FRAM
6GT2 600-5AK00
8 kByte FRAM
6GT2 600-5AB00
8 kByte FRAM
(8 KB ISO Tags)
13.56 MHz
Passive Tags
-40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 125°C -40°C to 100°C -40°C to 125°C -40°C to 90°C
Operational temperature range Ø 10 x 4.5 Ø 24 x 20 Ø 16 x 3
Ø 20 x 6 Ø 27 x 4 Ø 24 x 10 Ø 50 x 3.6
Dimensions (L x W x D) mm
IP67/IPx9K IP68 IP67 / IPx9k IP68 / IPx9k IP68 IP68/IPx9K IP68/IPx9K
Ingress Protection (IP) rating

RF310R
RS422 1-70/78 1-22/25 5-80/90 1-43/48 1-32/38
6GT2 801-1BA10 Integrated
6GT2 801-1BA10-0AX1 (90°plate) 55 x 75 x 30 (0.04-2.76/ 3.07) (0.04-0.87/ 0.98) (0.2-3.14/ 3.54) (0.04-1.69/ 1.89) (0.04-1.26/ 1.5)
6GT2 801-1BA10-0AX2 (Ex)

RF340R
RS422 2-55/70 2-20/30 1-80/100 2-40/50 2-25/40
Integrated
6GT2 801-2BA10 75 x 75 x 41 (0.08-2.16/ 2.76) (0.08-0.79/ 1.18) (0.04-3.15/ 3.94) (0.08-1.57/ 1.97) (0.08-0.98/ 1.57)
6GT2 801-2BA10-0AX2 (Ex)

RF350R ANT 1
RS422 2-65/85 2-25/35 1-85/105 2-35/50 2-32/38
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.08-2.56/ 3.35) (0.08-0.98/ 1.38) (0.04-3.35/ 4.13) (0.08-1.38/ 1.97) (0.08-1.26/ 1.5)
6GT2 398-1CB00 (ANT 1) 75 x 75 x 20

RF350R ANT 3
RS422 1-19/22 5-46/50 2-21/24 2-24/26 1-20/28
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0.04-0.75/ 0.87) (0.2-1.81/ 1.97) (0.08-0.83/ 0.94) (0.08-0.94/ 1.02) (0.04-0.79/ 1.1)
6GT2 398-1CD40-0AX0 (ANT 3)
28 x 50 x 10

RF350R ANT 8
RS422 0-3/4
(0.0-0.12/0.16)
6GT2 398-1CF10
Ø8 x 38
6GT2 398-1CF00

Spacer
Spacer Spacer (6GT2 690-0AG00)
Accessories
(6GT2 690-0AK00) (6GT2 690-0AL00) Angle pattern body
(6GT2690-0AN00)

* antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC00 (ANT12) or 6GT2398-1DA00 (ANT18)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
32 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas
D521 D522 D524 D525 D526 D528 D560
Family Matrix 6GT2 600-5AE00
8 kByte FRAM
6GT2 600-5AF00
8 kByte FRAM
6GT2 600-5AC00
8 kByte FRAM
6GT2 600-5AG00
8 kbyte FRAM
6GT2 600-5AH00
8 kByte FRAM
6GT2 600-5AK00
8 kByte FRAM
6GT2 600-5AB00
8 kByte FRAM
(8 KB ISO Tags)
13.56 MHz
Passive Tags
-40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 125°C -40°C to 100°C -40°C to 125°C -40°C to 90°C
Operational temperature range Ø 10 x 4.5 Ø 24 x 20 Ø 16 x 3
Ø 20 x 6 Ø 27 x 4 Ø 24 x 10 Ø 50 x 3.6
Dimensions (L x W x D) mm
IP67/IPx9K IP68 IP67 / IPx9k IP68 / IPx9k IP68 IP68/IPx9K IP68/IPx9K
Ingress Protection (IP) rating

RF350R ANT 12
RS422 0-3/5 1-10/17 1-8/10
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0-0.12/ 0.2) (0.04-0.40/ 0.67) (0.04-0.31/ 0.39)
Ø12 x 40
6GT2 398-1DC10 (ANT 12) *)

RF350R ANT 18
RS422 0-6/8 1-10/13 1-27/35 1-10/14 1-15/20 1-12/16
6GT2 801-4BA10
6GT2 801-4BA10-0AX2 (Ex) (0-0.24/ 0.31) (0.04-0.39/ 0.51) (0.04-1.06/ 1.38) (0.04-0.39/ 0.55) (0.04-0.59/ 0.79) (0.04-0.47/ 0.63)
6GT2 398-1DA10 (ANT 18) *) Ø18 x 40

RF350R ANT 30
RS422 1-15/ 18 0-45/ 50 1-15/ 20 0-45/ 48 1-25/ 28 1-18/ 20
6GT2 801-4BA10
(0.04-0.59/ 0.70) (0-1.77/ 1.97) (0.04-0.59/ 0.79) (0-1.77/ 1.89) (0.04-0.98/ 1.10) (0.04-0.71/ 0.79)
6GT2 801-4BA10-0AX2 (Ex)
Ø30 x 40
6GT2 398-1DD10 (ANT 30)

RF360R
Ethernet
Integrated 2-55/ 70 1-80/ 100
6GT2 801-5BA30 141 x 80 x 42 (0.08-2.17/ 2.76) (0.04-3.15/ 3.94)

RF380R
RS422, RS232
Integrated 2-115/ 130 2-35/ 50 2-155/ 195 2-70/ 95 2-65/ 90
6GT2 801-3BA10 160 x 96 x 41 (0.08-4.52/ 5.12) (0.08-1.38/ 1.97) (0.08-6.10/ 7.68) (0.08-2.76/ 3.74) (0.08-2.56/ 3.54)
6GT2 801-3BA10-0AX2 (Ex)

Spacer
Spacer Spacer (6GT2 690-0AG00)
Accessories
(6GT2 690-0AK00) (6GT2 690-0AL00) Angle pattern body
(6GT2690-0AN00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
33 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas
E600 E611
E623 E624
6GT2 300-0CD00 6GT2 300-0CE00
Family Matrix 6GT2 300-0AA00
752 byte EEPROM
6GT2 300-0BB00
752 byte EEPROM
752 byte EEPROM 752 byte EEPROM

(MOBY E compatibility)
13.56 MHz
Passive Tags
-40°C to 100°C -40°C to 150°C
-25°C to 60°C -40°C to 85°C Ø10 x 4.5 Ø 27 x 4
Operational temperature range IP67/ IPx9K
86 x 54 x 0.76 86 x 54 x 2.5 IP67/ IPx9K
Dimensions (L x W x D) mm
Ingress Protection (IP) rating IP68 IP67

RF310R
RS422 2-30/ 43 2-40/ 60 2-35/ 36
6GT2 801-1BA10 Integrated
(0.08-1.18/ 1.69) (0.08-1.57/ 2.36) (0.08-1.37/ 1.42)
6GT2 801-1BA10-0AX1 (90°plate) 55 x 75 x 30
6GT2 801-1BA10-0AX2 (Ex)

RF340R
RS422 5-50/ 65 10-50/ 65 2-35/ 45
Integrated
(0.2-1.97/ 2.56) (0.39-1.97/ 2.56) (0.08-1.37/ 1.77)
6GT2 801-2BA10 75 x 75 x 41
6GT2 801-2BA10-0AX2 (Ex)

RF350R ANT 1
RS422 10-50/ 60 20-50/ 65 2-35/ 45
6GT2 801-4BA10
(0.39-1.97/ 2.36) (0.79-1.97/ 2.56) (0.08-1.37/ 1.77)
6GT2 801-4BA10-0AX2 (Ex)
6GT2 398-1CB00 (ANT 1) 75 x 75 x 20

RF350R ANT 3
RS422
6GT2 801-4BA10
1-15/ 16
(0.04-0.59/ 0.63)
6GT2 801-4BA10-0AX2 (Ex)
6GT2 398-1CD40-0AX0 (ANT 3)
28 x 50 x 10

RF350R ANT 8
RS422

6GT2 398-1CF10 Ø8 x 38
6GT2 398-1CF00

Holder Holder
(6GT2 390-0AA00) (6GT2 390-0AA00)
20 mm spacer 20 mm spacer Spacer
Accessories (6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 690-0AK00)
Fixing pocket Fixing pocket
(6GT2 190-0AB00) (6GT2 190-0AB00)

* antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC00 (ANT12) or 6GT2398-1DA00 (ANT18)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
34 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300 Antennas
E600 E611
E623 E624
6GT2 300-0CD00 6GT2 300-0CE00
Family Matrix 6GT2 300-0AA00
752 byte EEPROM
6GT2 300-0BB00
752 byte EEPROM
752 byte EEPROM 752 byte EEPROM

(MOBY E compatibility)
13.56 MHz
Passive Tags
-40°C to 100°C -40°C to 150°C
-25°C to 60°C -40°C to 85°C Ø10 x 4.5 Ø 27 x 4
Operational temperature range IP67/ IPx9K
86 x 54 x 0.76 86 x 54 x 2.5 IP67/ IPx9K
Dimensions (L x W x D) mm
Ingress Protection (IP) rating IP68 IP67

RF350R ANT 12
RS422 0-3/ 5
6GT2 801-4BA10
(0-0.12/ 0.20)
6GT2 801-4BA10-0AX2 (Ex)
6GT2 398-1DC10 (ANT 12) *) Ø12 x 40

RF350R ANT 18
RS422 0-6/ 8 2-10/ 15
6GT2 801-4BA10
(0-0.24/ 0.31) (0.08-0.40/ 0.59)
6GT2 801-4BA10-0AX2 (Ex)
6GT2 398-1DA10 (ANT 18) *) Ø18 x 40

RF350R ANT 30
RS422 1-20/ 24
6GT2 801-4BA10
(0.04-0.79/ 0.94)
6GT2 801-4BA10-0AX2 (Ex)
6GT2 398-1DD10 (ANT 30) Ø30 x 40

RF380R
RS422, RS232
Integrated 10-80/ 95 10-115/ 135 5-50/ 60
6GT2 801-3BA10 160 x 96 x 41 (0.39-3.15/ 3.74) (0.39-4.53/ 5.31) (0.20-1.97/ 2.36)
6GT2 801-3BA10-0AX2 (Ex)

Holder Holder
(6GT2 390-0AA00) (6GT2 390-0AA00)
20 mm spacer 20 mm spacer Spacer
Accessories (6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 690-0AK00)
Fixing pocket Fixing pocket
(6GT2 190-0AB00) (6GT2 190-0AB00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
35 Unrestricted | © Siemens 2023 | All rights reserved.
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF300
System Interfaces

36 Unrestricted | © Siemens 2023 | All rights reserved.


RF300 Reader Tags
System Interfaces with external power supply

RF320T
(6GT2 800-1CA00)

PROFINET & OPC UA & TCP/IP


RF330T
(6GT2 800-5BA00)

+ Direct connection

Ethernet /PN Cable M12


+ RF340T
(8 kb: 6GT2 800-4BB00)
(32 kb: 6GT2 800-5BB00)
length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required)

RF350T
(6GT2 800-5BD00)

RF360R
6GT2801-5BA30
Controller Library and Network Connection via Switch RF360T

+
Demo-Software on DVD (8 kb: 6GT2 800-4AC00)

+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + Ethernet /PN Cable M12
(32 kb: 6GT2 800-5AC00)

length from 2 to 15 m available


e.g. 2 m = 6XV1871-5TH20
RF370T
(32 kb: 6GT2 800-5BE00)
IE switch SCALANCE X
Power supply (64 kb: 6GT2 800-6BE00)
General host application as (6GK5 …) EU connector
a, XML client 6GT2 898-0AC00
b, Off-the-shelf third-party RFID Middleware
UK connector RF380T
c, OPC UA for AutoID Client (6GT2 800-5DA00)
6GT2 898-0AC10
Controller Application written in
any controller language using Ident library US connector
with Ident profile 6GT2 898-0AC20
cable 24 V for power supply ISO TAGs
5 m = 6GT2 091-0PH50 D100 6GT2 600-0AD10
D200 6GT2 600-1AD00-0AX0
cable M12 L-coded D400 6GT2 600-4AD00
180° = 6XV1801-6Dxxx*
D124 6GT2 600-0AC10
90° = 6XV1801-6Gxxx*
D324 6GT2 600-3AC00
D424 6GT2 600-4AC00
D524 6GT2 600-5AC00
Cover caps D226s 6GT2600-2BA00
3RX9 802-0AA00 D426s 6GT2600-4BA00
D126 6GT2 600-0AE00
D426 6GT2 600-4AH00
D526 6GT2 600-5AH00
D139 6GT2 600-0AA10
D339 6GT2 600-3AA10
* More details on page 90

37 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF300 Reader Tags
System Interfaces powered through connection cable

RF320T
(6GT2 800-1CA00)

PROFINET & OPC UA & Ethernet/IP & TCP/IP


RF330T
(6GT2 800-5BA00)

RF310R RS422
6GT2 801-1BA10
6GT2801-1BA10-0AX1 (90°plate) RF340T
Communication Modules A maximum of 6GT2801-1BA10-0AX2 (Ex) (8 kb: 6GT2 800-4BB00)
1 reader at RF185C, (32 kb: 6GT2 800-5BB00)
2 readers at RF186C/CI,
4 readers at RF188C/CI
RF350T
of RF3x0R may be connected (6GT2 800-5BD00)

RF185C
(6GT2 002-0JE10)
RF186C
(6GT2 002-0JE20)
RF188C
(6GT2 002-0JE40)
+ 2 m = 6GT2 891-4FH20
10 m = 6GT2 891-4FN10
5 m = 6GT2 891-4FH50
20 m = 6GT2 891-4FN20 RF360T
50 m = 6GT2 891-4FN50* (8 kb: 6GT2 800-4AC00)
RF340R (32 kb: 6GT2 800-5AC00)
Reader connector 90° angled: 6GT2 801-2BA10
2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 6GT2801-2BA10-0AX2 (Ex)
10 m = 6GT2 891-4JN10
Additional IOs RF370T
(32 kb: 6GT2 800-5BE00)
(64 kb: 6GT2 800-6BE00)
ANT 1
(6GT2 398-1CB00)

+ + Types of IO-Link
IO module
ANT 3
(6GT2 398-1CD40-0AX0)
RF380T
(6GT2 800-5DA00)
IO-extension module
RF18xCI to sensor ANT 12
RF186CI RF188CI 6ES7 14….. (up to 8xDI + 8xDO) ISO TAGs
Sensor cable from (6GT2398-1DC10
D100 6GT2 600-0AD10
(6GT2 002-0JE50) (6GT2 002-0JE60) 0.5 to 15 m available D200 6GT2 600-1AD00-0AX0
See page 88 for detailed information ANT 18 D400 6GT2 600-4AD00
(e.g. 2 m = 6XV1801-2CH20)
(6GT2398-1DA10) D117 6GT2 600-0AG00
RF350R D421 6GT2 600-4AE00
6GT2 801 ANT 30 D422 6GT2 600-4AF00
-4BA10, (6GT2398-1DD10) D423 6GT2 600-4AA00
/-4BA10-0AX2 D124 6GT2 600-0AC10
(Ex) D324 6GT2 600-3AC00
D424 6GT2 600-4AC00
Or one D226s 6GT2600-2BA00
D426s 6GT2600-4BA00
Standard sensor D425 6GT2 600-4AG00
D126 6GT2 600-0AE00
Or one D426 6GT2 600-4AH00
D127 6GT2 600-0AF00
Actor D428 6GT2 600-4AK00-0AX0
D139 6GT2 600-0AA10
D339 6GT2 600-3AA10
D160 6GT2 600-0AB10
RF380R D460 6GT2 600-4AB00
6GT2 801-3BA10 D560 6GT2600-5AB00
6GT2801-3BA10-0AX2 (Ex) D261 6GT2 600-1AA01-0AX0
D165 6GT2 600-1AB00-0AX0

38 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF300 Reader Tags
A maximum of 1 readers may be connected
System Interfaces + RF120C to RF3x0R
2 m = 6GT2 091-4LH20 5 m = 6GT2 091-4LH50
+ powered through connection cable

RF320T
10m = 6GT2 091-4LN10 (6GT2 800-1CA00)

SIMATIC PLC RF120C


And extension cables:
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
6GT2 002-0LA00 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 RF330T
(S7-1200) Up to 3 x RF120C modules
50 m = 6GT2 891-4FN50
2 m = 6GT2 891-4JH20 Reader connector 90° angled
(6GT2 800-5BA00)

per S7-1200 rack 5 m = 6GT2 891-4JH50 Reader connector 90° angled RF310R RS422
10 m = 6GT2 891-4JN10 Reader connector 90° angled 6GT2 801-1BA10
6GT2801-1BA10-0AX1 (90°plate) RF340T
6GT2801-1BA10-0AX2 (Ex) (8 kb: 6GT2 800-4BB00)
(32 kb: 6GT2 800-5BB00)
SIMATIC PLC A maximum of 2 Readers may be connected
S7-300 Rack or + + ASM 475 to RF3x0R + RF350T
(6GT2 800-5BD00)
2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50
S7-400 via ET 200M And Extension Cables:
(DP-V1/PN-IO) ASM 475 + Front Connector
2 m = 6GT2 891-4FH20
10 m = 6GT2 891-4FN10
5 m = 6GT2 891-4FH50
20 m = 6GT2 891-4FN20
RF360T
(8 kb: 6GT2 800-4AC00)
(6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0) 50 m = 6GT2 891-4FN50 RF340R (32 kb: 6GT2 800-5AC00)
2 m = 6GT2 891-4JH20 Reader connector 90° angled 6GT2 801-2BA10
Accessories:
5 m = 6GT2 891-4JH50 Reader connector 90° angled 6GT2801-2BA10-0AX2 (Ex)
Connecting element (6ES7 390-5AA00-0AA0)
10 m = 6GT2 891-4JN10 Reader connector 90° angled
Terminal element (6ES7 390-5BA00-0AA0)
RF370T
(32 kb: 6GT2 800-5BE00)
(64 kb: 6GT2 800-6BE00)

ET 200pro ET 200pro PROFIBUS DP-V1


Interface Modul
ANT 1
(6GT2 398-1CB00)
RF380T
via PROFIBUS ET 200pro PROFINET
ANT 3
(6GT2 398-1CD40-0AX0)
(6GT2 800-5DA00)

or PROFINET Interface Modul


+ + A maximum of 2 readers may be connected
RF170C to RF3x0R + ANT 12
(6GT2398-1DC10
ISO TAGs
or S7 PLC00 ET 200pro PROFINET 2 m = 6GT2 891-4FH20
10 m = 6GT2 891-4FN10
5 m = 6GT2 891-4FH50
20 m = 6GT2 891-4FN20 ANT 18
D100 6GT2 600-0AD10
D200 6GT2 600-1AD00-0AX0
CPU module RF170C D400 6GT2 600-4AD00
50 m = 6GT2 891-4FN50 (6GT2398-1DA10) D117 6GT2 600-0AG00
Communication Module
Up to 9 x 170C (6GT2002-0HD01)
RF350R D421 6GT2 600-4AE00
Reader connector 90° angled 6GT2 801 ANT 30 D422 6GT2 600-4AF00
modules per Connection Block
-4BA10, (6GT2398-1DD10) D423 6GT2 600-4AA00
(6GT2002-1HD01) 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50
ET 200pro rack 10 m = 6GT2 891-4JN10 /-4BA10-0AX2 D124 6GT2 600-0AC10
(Ex) D324 6GT2 600-3AC00
D424 6GT2 600-4AC00
D226s 6GT2600-2BA00
A maximum of 2 readers may be connected D426s 6GT2600-4BA00

PROFIBUS + RF166C to RF2x0R


2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
+ D425 6GT2 600-4AG00
D126 6GT2 600-0AE00
D426 6GT2 600-4AH00
D127 6GT2 600-0AF00
D428 6GT2 600-4AK00-0AX0
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
D139 6GT2 600-0AA10
50 m = 6GT2 891-4FN50* D339 6GT2 600-3AA10
D160 6GT2 600-0AB10
Reader connector 90° angled RF380R D460 6GT2 600-4AB00
RF166C (DP-V1) 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 6GT2 801-3BA10 D560 6GT2600-5AB00
Communication Module 10 m = 6GT2 891-4JN10 6GT2801-3BA10-0AX2 (Ex) D261 6GT2 600-1AA01-0AX0
(6GT2 002-0EE20) D165 6GT2 600-1AB00-0AX0

39 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF300 Reader Tags
System Interfaces with external power supply

RF320T
(6GT2 800-1CA00)

RS232/RS422
RF330T
(6GT2 800-5BA00)
RS232
RS232 RS422
1 Reader per COM port may be connected
+ Open Wire to RF310R Scanmode
+ RF310R Scanmode
(6GT2 801-1BA20-0AX1)
RF340T
(8 kb: 6GT2 800-4BB00)
(32 kb: 6GT2 800-5BB00)
RS422 24VDC OUT 2 m = 6GT2 891-4EH20
5 m = 6GT2 891-4EH50
No Driver needed RF350T
Scanmode; Read only Interface Converter (6GT2 800-5BD00)
24VDC IN
(ie. TRP-C06 Trycom IP)
RF360T
(8 kb: 6GT2 800-4AC00)
(32 kb: 6GT2 800-5AC00)

RF370T
(32 kb: 6GT2 800-5BE00)
(64 kb: 6GT2 800-6BE00)

Reader
ANT 1
(6GT2 398-1CB00)
RS232 with external power supply at Y-cable
ANT 3 RF380T
(6GT2 800-5DA00)
(6GT2 398-1CD40-0AX0)

ANT 12 ISO TAGs


(6GT2398-1DC10
D100 6GT2 600-0AD10
D200 6GT2 600-1AD00-0AX0
ANT 18 D400 6GT2 600-4AD00
(6GT2398-1DA10)
1 Reader per COM port may be connected
+
D117 6GT2 600-0AG00
RF350R D421 6GT2 600-4AE00
6GT2 801 ANT 30
+
D422 6GT2 600-4AF00
Wide-Range power supply + 5 m cable RS 232 cable for RF382R -4BA10, (6GT2398-1DD10) D423 6GT2 600-4AA00
5 m = 6GT2 891-4KH50 /-4BA10-0AX2 D124 6GT2 600-0AC10
6GT2 898-0ACxx + 6GT2 491-1HH50
(Ex) D324 6GT2 600-3AC00
Extension cables: 5 m = 6GT2 891-4FH50 RF382R D424 6GT2 600-4AC00
10 m = 6GT2 891-4FN10 (6GT2 801-3AB20-0AX0) D226s 6GT2600-2BA00
D426s 6GT2600-4BA00
No Driver needed D425 6GT2 600-4AG00
D126 6GT2 600-0AE00
Scanmode; Read only D426 6GT2 600-4AH00
D127 6GT2 600-0AF00
D428 6GT2 600-4AK00-0AX0
D139 6GT2 600-0AA10
D339 6GT2 600-3AA10
D160 6GT2 600-0AB10
D460 6GT2 600-4AB00
D560 6GT2600-5AB00
D261 6GT2 600-1AA01-0AX0
D165 6GT2 600-1AB00-0AX0

40 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF600
Family Matrix
865-868 MHz (ETSI)
902-928 MHz (FCC)
Passive Tags (with Gen2 protocol)

41 Unrestricted | © Siemens 2023 | All rights reserved.


RF630L RF630L RF630L
RF600 Antennas
6GT2 810-2AE82-0AX0 6GT2 810-2AE83-1AX0
RF630L
6GT2 810-2AC84
6GT2 810-2AB04-
Family Matrix Operational Temperature Range
…/-0AX1 /-0AX2 /-1AX0
/-2AX0 /-2AX1
128 bits EPC 0AX1
96 bits EPC,
448 bits EPC,
256 byte
Dimensions ( L x W x D) mm 128 bits EPC
865-868 MHz (ETSI) 256 byte
Ingress Protection (IP) Rating
902-928 MHz (FCC)
Passive Tags (with Gen2 protocol)
-25°C to 160°C -25°C to 130°C -20°C to 160°C -40°C to 85°C
various sizes* 45 x 20 74 x 27 73 x 12.5
IP67 IP67 washable IP60 IP67

RF615R*** (IP67)
(internal antenna used)
6GT2 811-6CC10-0AA0 (ETSI)
6GT2 811-6CC10-1AA0 (FCC)
6GT2 811-6CC10-2AA0 (CMIIT)

Integrated 0.8 0.6 0.7 1


RF610R*** (IP67) (31) (24) (27) (39)
(internal antenna used) 133 x 133 x 45

6GT2 811-6BC10-0AA0 (ETSI)


6GT2 811-6BC10-1AA0 (FCC)
6GT2 811-6BC10-2AA0 (CMIIT)

RF615A***

RF615R*** (IP67) 0.4 0.4 0.4 0.25


(16) (16) (16) (10)
(external antenna used)
52 x 52 x 16
6GT2 811-6CC10-0AA0 (ETSI) RF622A***
6GT2 811-6CC10-1AA0 (FCC)
6GT2 811-6CC10-2AA0 (CMIIT) 0.4 0.4 0.4 0.25
(16) (16) (16) (10)
75 x 75 x 20
RF642A**

3.0 3.0 3.0 3.0


(118) (118) (118) (118)
185 x 185 x 45
RF650A**
1.4 1.0 1,2 1.6
Antennas: (55) (39) (48) (63)
6GT2 812-0EA00 RF615A, linear, (ETSI) 198 x 198 x 60
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT) RF662 A
6GT2 812-2EA00 RF622A, linear, (ETSI)
6GT2 812-2EA01 RF622A, linear, (FCC, CMIIT) 3.0 2.5 2.5 3.0
6GT2 812-1GA08 RF642A, linear, (all readers) (118) (98) (98) (118)
6GT2 812-0GB08 RF650A, circular, (all readers) 312 x 312 x 68
6GT2 812-1AA08 RF662A, circular, (all readers) RF680A**
6GT2 812-2GB08 RF680A, switchable,(all readers)
1.6 1.0 1.6 1.6
(63) (39) (63) (63)
198 x 198 x 60
** 3-way
mounting kit
Accessories (6GT2 890-2AB10)
*** mounting plate
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch)


* For detailed size information see technical data
42 Unrestricted | © Siemens 2023 | All rights reserved. pay attention to the system manual for range overshoot

SIMATIC Ident Configuration Guide


RF630L RF630L RF642L RF682L
RF600 Antennas
6GT2 810-2AE83-0AX1 6GT2 810-2AE81-0AX3 6GT2 810-3AC00 (ETSI) 6GT2 810-2AG84-0AX2
Family Matrix Operational Temperature Range
448 bit EPC, 256 Byte 448 bit EPC, 256 Byte 6GT2 810-3AC10 (FCC)
448 bit EPC, 256 byte
448 bits EPC, 256 Byte

Dimensions ( L x W x D) mm
865-868 MHz (ETSI) Ingress Protection (IP) Rating
902-928 MHz (FCC)
Passive Tags (with Gen2 protocol)
-25°C to 130°C -40°C to 120°C -25°C to 85°C -40°C to 230°C
105 x 25 75 x 20 50 x 22.5 x 1.6 156 x 40
IP67 IP67 IP68 IP67
RF615R*** (IP67)
(internal antenna used)
6GT2 811-6CC10-0AA0 (ETSI)
6GT2 811-6CC10-1AA0 (FCC)
6GT2 811-6CC10-2AA0 (CMIIT)

Integrated 0.8 1 1.0 1.2


RF610R*** (IP67) (31) (39) (39) (47)
(internal antenna used) 133 x 133 x 45

6GT2 811-6BC10-0AA0 (ETSI)


6GT2 811-6BC10-1AA0 (FCC)
6GT2 811-6BC10-2AA0 (CMIIT)

RF615A***

RF615R*** (IP67) 0.4 0.25 0.25 0.7


(16) (9.8) (9.8) (28)
(external antenna used)
52 x 52 x 16
6GT2 811-6CC10-0AA0 (ETSI) RF622A***
6GT2 811-6CC10-1AA0 (FCC)
6GT2 811-6CC10-2AA0 (CMIIT) 0.5 0.25 0.4 0.9
(20) (9.8) (16) (35)
75 x 75 x 20
RF642A**

3.5 3.0 2.0 4.5


(138) (118) (79) (177)
185 x 185 x 45
RF650A**
1.4 1.6 0.8 2.5
Antennas: (55) (63) (31) (98)
6GT2 812-0EA00 RF615A, linear, (ETSI) 198 x 198 x 60
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT) RF662 A
6GT2 812-2EA00 RF622A, linear, (ETSI)
6GT2 812-2EA01 RF622A, linear, (FCC, CMIIT) 3.0 3.0 1.8 4.5
6GT2 812-1GA08 RF642A, linear, (all readers) (118) (118) (71) (177)
6GT2 812-0GB08 RF650A, circular, (all readers) 312 x 312 x 68
6GT2 812-1AA08 RF662A, circular, (all readers) RF680A**
6GT2 812-2GB08 RF680A, switchable,(all readers)
1.6 1.6 1.0 2.5
(63) (63) (39) (98)
198 x 198 x 60
** 3-way
mounting kit
Accessories (6GT2 890-2AB10)
*** mounting plate
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch)


43 Unrestricted | © Siemens 2023 | All rights reserved. pay attention to the system manual for range overshoot

SIMATIC Ident Configuration Guide


RF610T RF620T RF621T RF625T RF630T
RF600 Antennas
6GT2 810-2BB80 6GT2 810-3HC80 6GT2 810-1HC80 6GT2 810-2EE00 (ETSI) 6GT2 810-2EC00 (ETSI)
6GT2 810-2EC10 (FCC)
Family Matrix Operational Temperature Range
448 bit EPC,
256 byte
96 bit EPC,
256 byte
16/128 bit EPC,
16 byte
6GT2 810-2EE01 (FCC)
96/128 bit EPC, 96/240 bit EPC,
64 byte
Dimensions ( L x W x D) mm 64 byte
865-868 MHz (ETSI) Ingress Protection (IP) Rating
902-928 MHz (FCC)
Passive Tags (with Gen2 protocol)
-40°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 125°C -40°C to 125°C
86 x 54 x 0.4 127 x 38 x 6 120 x 30 x 6,5 Ø 30 x 8 Ø 21x 20
IP67 IP67 IP67 IP68/ IPx9K IP68/ IPx9K
RF615R*** (IP67)
(internal antenna used)
6GT2 811-6CC10-0AA0 (ETSI)
6GT2 811-6CC10-1AA0 (FCC)
6GT2 811-6CC10-2AA0 (CMIIT)

Integrated 1 2.5 2.0 0.1 0.15


RF610R*** (IP67) (39) (98) (79) (4) (6)
(internal antenna used) 133 x 133 x 45

6GT2 811-6BC10-0AA0 (ETSI)


6GT2 811-6BC10-1AA0 (FCC)
6GT2 811-6BC10-2AA0 (CMIIT)

RF615A***

RF615R*** (IP67) 0.3 1.0 0.8 0.1 0.1


(12) (39) (31) (4) (4)
(external antenna used)
52 x 52 x 16
6GT2 811-6CC10-0AA0 (ETSI) RF622A***
6GT2 811-6CC10-1AA0 (FCC)
6GT2 811-6CC10-2AA0 (CMIIT) 0.4 1.2 1.2 0.1 0.15
(16) (47) (47) (4) (6)
75 x 75 x 20
RF642A**

3.0 4.0 5.0 1 0.5


(118) (157) (20) (39) (20)
185 x 185 x 45
RF650A**
1.2 3.5 2.2 0.25 0.4
Antennas: (47) (138) (55) (8) (16)
6GT2 812-0EA00 RF615A, linear, (ETSI) 198 x 198 x 60
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT) RF662 A
6GT2 812-2EA00 RF622A, linear, (ETSI)
6GT2 812-2EA01 RF622A, linear, (FCC, CMIIT) 3.0 4.0 7.0 0.8 1.0
6GT2 812-1GA08 RF642A, linear, (all readers) (118) (157) (177) (31) (39)
6GT2 812-0GB08 RF650A, circular, (all readers) 312 x 312 x 68
6GT2 812-1AA08 RF662A, circular, (all readers) RF680A**
6GT2 812-2GB08 RF680A, switchable,(all readers)
1.4 4.0 2.2 0.2 0.5
(55) (157) (55) (8) (20)
198 x 198 x 60
** 3-way
20 mm Spacer
mounting kit (6GT2 190-0AA00) Spacer Spacer
Accessories (6GT2 890-2AB10) Fixing pocket (6GT2 898-2AA00) (6GT2 898-3AA00)
*** mounting plate (6GT2 190-0AB00)
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch)


44 Unrestricted | © Siemens 2023 | All rights reserved. pay attention to the system manual for range overshoot

SIMATIC Ident Configuration Guide


RF640T RF645T RF680T RF682T
RF600 Antennas
6GT2 810-2DC00 (ETSI) 6GT2 810-2HC05 6GT2 810-2HG81 6GT2 810-3HG81
RF683T
6GT2 810-3HG00
Family Matrix Operational Temperature Range
6GT2 810-2DC10 (FCC)
96/240 bit EPC,
448 bit EPC,
256 byte
96/240 bit EPC,
64 byte
256 bit EPC,
384 byte
256 bit EPC,
32 byte
Dimensions ( L x W x D) mm 64 byte
865-868 MHz (ETSI) Ingress Protection (IP) Rating
902-928 MHz (FCC)
Passive Tags (with Gen2 protocol)
-40°C to 125°C -40°C to 85°C -40°C to 220°C -40°C to 220°C -40°C to 220°C
Ø 50 x 8 52 x 36 x 12,5 130 x 32 x 15 130 x 32 x 15 130 x 32,6 x 16,5
IP68/ IPx9K IP68 IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K
RF615R*** (IP67)
(internal antenna used)
6GT2 811-6CC10-0AA0 (ETSI)
6GT2 811-6CC10-1AA0 (FCC)
6GT2 811-6CC10-2AA0 (CMIIT)

Integrated 0.2 1.0 1.2 0.8 2.0


RF610R*** (IP67) (7.9) (39) (47) (31) (79)
(internal antenna used) 133 x 133 x 45

6GT2 811-6BC10-0AA0 (ETSI)


6GT2 811-6BC10-1AA0 (FCC)
6GT2 811-6BC10-2AA0 (CMIIT)

RF615A***

RF615R*** (IP67) 0.2 0.7 0.6 0.4 0,5


(8) (28) (24) (16) (20)
(external antenna used)
52 x 52 x 16
6GT2 811-6CC10-0AA0 (ETSI) RF622A***
6GT2 811-6CC10-1AA0 (FCC)
6GT2 811-6CC10-2AA0 (CMIIT) 0.2 0.9 0.7 0.4 0,5
(8) (35) (28) (16) (20)
75 x 75 x 20
RF642A**

1.4 3.0 4.0 2.5 5,0


(55) (118) (157) (98) (197)
185 x 185 x 45
RF650A**
0.7 1.6 1.8 1.2 2,5
Antennas: (28) (63) (71) (47) (98)
6GT2 812-0EA00 RF615A, linear, (ETSI) 198 x 198 x 60
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT) RF662 A
6GT2 812-2EA00 RF622A, linear, (ETSI)
6GT2 812-2EA01 RF622A, linear, (FCC, CMIIT) 1.2 3.5 4.0 2.0 5,0
6GT2 812-1GA08 RF642A, linear, (all readers) (47) (138) (157) (79) (197)
6GT2 812-0GB08 RF650A, circular, (all readers) 312 x 312 x 68
6GT2 812-1AA08 RF662A, circular, (all readers) RF680A**
6GT2 812-2GB08 RF680A, switchable,(all readers)
1.2 1.8 2.0 1.2 2,5
(47) (71) (79) (47) (98)
198 x 198 x 60
** 3-way
mounting kit Mounting cover 6GT2898-5AA00
Retaining bracket Retaining bracket
Accessories (6GT2 890-2AB10) Retaining bracket 6GT2890-2AA00 6GT2890-2AA00
*** mounting plate 6GT2898-5AB00
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch)


45 Unrestricted | © Siemens 2023 | All rights reserved. pay attention to the system manual for range overshoot

SIMATIC Ident Configuration Guide


RF630L RF630L RF630L
RF600 Antennas
6GT2 810-2AE82-0AX0 6GT2 810-2AE83-1AX0
RF630L
6GT2 810-2AC84
6GT2 810-2AB04-
Family Matrix Operational Temperature Range
…/-0AX1 /-0AX2 /-1AX0
/-2AX0 /-2AX1
128 bits EPC 0AX1
96 bits EPC,
448 bits EPC,
256 byte
Dimensions ( L x W x D) mm 128 bits EPC
865-868 MHz (ETSI) 256 byte
Ingress Protection (IP) Rating
902-928 MHz (FCC)
Passive Tags (with Gen2 protocol)
-25°C to 160°C -25°C to 130°C -20°C to 160°C -40°C to 85°C
various sizes* 45 x 20 74 x 27 73 x 12.5
IP67 IP67 washable IP60 IP67

RF685R** (IP65)
(internal antenna used)
6GT2 811-6CA10-0AA0 (ETSI) Integrated 5.0 4.0 5.0 5.0
6GT2 811-6CA10-1AA0 (FCC) (197) (157) (197) (197)
260 x 193 x 52
6GT2 811-6CA10-2AA0 (CMIIT)
6GT2 811-6CA10-4AA0 (ARIB)

RF615A***
RF685R** (IP65)
(external antenna used)
1.2 / *0.8 0.4 1.2 / *0.7 1.4 / *1.0
(47 / *31) (16) (47 / *27) (55 / *39)
6GT2 811-6CA10-0AA0 (ETSI) 52 x 52 x 16
6GT2 811-6CA10-1AA0 (FCC)
6GT2 811-6CA10-2AA0 (CMIIT) RF622A***
6GT2 811-6CA10-4AA0 (ARIB) 1.2 / *0.8 0.4 1.2 / *0.8 1.4 / *1.0
(47 / *31) (16) (47 / *31) (55 / *39)
RF680R** (IP65) 75 x 75 x 20
6GT2 811-6AA10-0AA0 (ETSI) RF642A**
6GT2 811-6AA10-1AA0 (FCC) 5.0 / *4.5 5.0 / *4.5 5.0 / *4.0 5.0
6GT2 811-6AA10-2AA0 (CMIIT)
(197 / *177) (197 / *177) (197 / *157) (197)
6GT2 811-6AA10-4AA0 (ARIB)
185 x 185 x 45
RF650A**
RF650R** (IP30) 3.0 / *2.0 2.0 / *1.2 3.0 / *2.0 3.5 / *2.5
6GT2 811-6AB20-0AA0 (ETSI) (118 / *79) (79 / *47) (118 / *79) (138 / *98)
6GT2 811-6AB20-1AA0 (FCC) 198 x 198 x 60
6GT2 811-6AB20-2AA0 (CMIIT)
6GT2 811-6AB20-4AA0 (ARIB) RF662 A
4.0 4.0 / *3.5 4.0 / *3.5 4.0
Antennas: (157) (157 / *138) (157 / *138) (157)
6GT2 812-0EA00 RF615A, linear, (ETSI) 312 x 312 x 68
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT, ARIB)
6GT2 812-2EA00 RF622A, linear, (ETSI) RF680A**
6GT2 812-2EA01 RF622A, linear, (FCC, CMIIT, ARIB)
6GT2 812-1GA08 RF642A, linear, (all readers) 3.5 / *2.0 2.0 / *1.2 3.5 / *2.0 3.5 / *2.5
6GT2 812-0GB08 RF650A, circular, (all readers) (138 / *79) (79 / *47) (138 / *79) (138 / *98)
6GT2 812-1AA08 RF662A circular, (all readers)
6GT2 812-2GB08 RF680A, switchable (all readers) 198 x 198 x 60

** 3-way
mounting kit
Accessories (6GT2 890-2AB10)
*** mounting plate
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch)


* Use this value in combination with RF650R
46 Unrestricted | © Siemens 2023 | All rights reserved. pay attention to the system manual for range overshoot

SIMATIC Ident Configuration Guide


RF630L RF630L RF642L RF682L
RF600 Antennas
6GT2 810-2AE83-0AX1 6GT2 810-2AE81-0AX3 6GT2 810-3AC00 (ETSI) 6GT2 810-2AG84-0AX2

Family Matrix Operational Temperature Range


448 bit EPC, 256 Byte 448 bit EPC, 256 Byte 6GT2 810-3AC10 (FCC)
448 bit EPC,
448 bits EPC, 256 Byte

Dimensions ( L x W x D) mm 256 byte


865-868 MHz (ETSI) Ingress Protection (IP) Rating
902-928 MHz (FCC)
Passive Tags (with Gen2 protocol)
-25°C to 130°C -40°C to 120°C -25°C to 85°C -40°C to 230°C
105 x 25 75 x 20 50 x 22.5 x 1.6 156 x 40
IP67 IP67 IP68 IP67

RF685R** (IP65)
(internal antenna used)
6GT2 811-6CA10-0AA0 (ETSI) Integrated 5.0 5.0 2.0 6.0
6GT2 811-6CA10-1AA0 (FCC) (197) (197) (79) (236)
260 x 193 x 52
6GT2 811-6CA10-2AA0 (CMIIT)
6GT2 811-6CA10-4AA0 (ARIB)

RF615A***
RF685R** (IP65)
(external antenna used) 1.2 / *0.7 1.4 / *1.0 0.5 / *0.4 1.6 / *1.2
(47 / *28) (55 / *39) (20 / *16) (63 / *47)
6GT2 811-6CA10-0AA0 (ETSI) 52 x 52 x 16
6GT2 811-6CA10-1AA0 (FCC)
6GT2 811-6CA10-2AA0 (CMIIT) RF622A***
6GT2 811-6CA10-4AA0 (ARIB) 1.2 / *0.8 1.4 / *1.0 0.5 / *0.4 1.8 / *1.2
(47 / *31) (55 / *39) (20 / *16) (71 / *47)
RF680R** (IP65) 75 x 75 x 20
6GT2 811-6AA10-0AA0 (ETSI) RF642A**
6GT2 811-6AA10-1AA0 (FCC) 5.0 5.0 2.0 6.0
6GT2 811-6AA10-2AA0 (CMIIT)
(197) (197) (79) (236)
6GT2 811-6AA10-4AA0 (ARIB)
185 x 185 x 45
RF650A**
RF650R** (IP30) 3.5 / *2.0 3.5 / *2.5 1.6 / *1.2 4.0 / *3.0
6GT2 811-6AB20-0AA0 (ETSI) (138 / *79) (138 / *98) (63 / *47) (157 / *118)
6GT2 811-6AB20-1AA0 (FCC) 198 x 198 x 60
6GT2 811-6AB20-2AA0 (CMIIT)
6GT2 811-6AB20-4AA0 (ARIB) RF662 A
4.0 4.0 1.6 5.0
Antennas: (157) (157) (63) (197)
6GT2 812-0EA00 RF615A, linear, (ETSI) 312 x 312 x 68
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT, ARIB)
6GT2 812-2EA00 RF622A, linear, (ETSI) RF680A**
6GT2 812-2EA01 RF622A, linear, (FCC, CMIIT, ARIB)
6GT2 812-1GA08 RF642A, linear, (all readers) 4.0 / *2.5 3.5 / *2.5 1.6 / *1.2 5.0 / *3.0
6GT2 812-0GB08 RF650A, circular, (all readers) (157 / *98) (138 / *98) (63 / *47) (197 / *118)
6GT2 812-1AA08 RF662A circular, (all readers)
6GT2 812-2GB08 RF680A, switchable (all readers) 198 x 198 x 60

** 3-way
mounting kit
Accessories (6GT2 890-2AB10)
*** mounting plate
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch)


* Use this value in combination with RF650R
47 Unrestricted | © Siemens 2023 | All rights reserved. pay attention to the system manual for range overshoot

SIMATIC Ident Configuration Guide


RF630T
RF600 Antennas RF610T RF620T RF621T RF625T
6GT2 810-2EE00 (ETSI) 6GT2 810-2EC00 (ETSI)
6GT2 810-2BB80 6GT2 810-3HC80 6GT2 810-1HC80 6GT2 810-2EC10 (FCC)
Family Matrix Operational Temperature Range
Dimensions ( L x W x D) mm
448 bit EPC,
256 byte
96 bit EPC,
256 byte
16/128 bit EPC,
16 byte
6GT2 810-2EE01 (FCC)
96/128 bit EPC, 96/240 bit EPC,
64 byte
64 byte
865-868 MHz (ETSI) Ingress Protection (IP) Rating

902-928 MHz (FCC)


Passive Tags (with Gen2 protocol)
-40°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 125°C -40°C to 125°C
86 x 54 x 0.4 127 x 38 x 6 120 x 30 x 6,5 Ø 30 x 8 Ø 21x 20
IP67 IP67 IP67 IP68/ IPx9K IP68/ IPx9K

RF685R** (IP65)
(internal antenna used)
6GT2 811-6CA10-0AA0 (ETSI) Integrated 5.0 7.0 8,0 2.0 2.0
6GT2 811-6CA10-1AA0 (FCC) (197) (276) (315) (79) (79)
260 x 193 x 52
6GT2 811-6CA10-2AA0 (CMIIT)
6GT2 811-6CA10-4AA0 (ARIB)

RF615A***
RF685R** (IP65)
(external antenna used) 1.2 / *0.9 2.5 / *1.8 1,2 0.5 / *0.3 0.5 / *0.3
(47 / *35) (98 / *71) (47) (20 / *12) (20 / *12)
6GT2 811-6CA10-0AA0 (ETSI) 52 x 52 x 16
6GT2 811-6CA10-1AA0 (FCC)
6GT2 811-6CA10-2AA0 (CMIIT) RF622A***
6GT2 811-6CA10-4AA0 (ARIB) 1.4 / *0.9 2.5 / *1.8 1,4 0.5 / *0.4 0.5 / *0.4
(55 / *35) (98 / *71) (55) (20 / *16) (20 / *16)
RF680R** (IP65) 75 x 75 x 20
6GT2 811-6AA10-0AA0 (ETSI) RF642A**
6GT2 811-6AA10-1AA0 (FCC) 4.5 7.0 10,0 1.8 2.0
6GT2 811-6AA10-2AA0 (CMIIT)
(177) (275) (394) (71) (79)
6GT2 811-6AA10-4AA0 (ARIB)
185 x 185 x 45
RF650A**
RF650R** (IP30) 3.0 / *2.0 5.0 / *4.0 3,5 / *3,2 1.4 / *1.0 1.2 / *0.9
6GT2 811-6AB20-0AA0 (ETSI) (118 / *79) (197 / *157) (138 / *126) (55 / *39) (47 / *35)
6GT2 811-6AB20-1AA0 (FCC) 198 x 198 x 60
6GT2 811-6AB20-2AA0 (CMIIT)
6GT2 811-6AB20-4AA0 (ARIB) RF662 A
3.5 6.0 8,0 1.4 1.8
Antennas: (138) (236) (315) (55) (71)
6GT2 812-0EA00 RF615A, linear, (ETSI) 312 x 312 x 68
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT, ARIB)
6GT2 812-2EA00 RF622A, linear, (ETSI) RF680A**
6GT2 812-2EA01 RF622A, linear, (FCC, CMIIT, ARIB)
6GT2 812-1GA08 RF642A, linear, (all readers) 3.0 / *2.0 6.0 / *4.0 4,0 / *3,2 1.2 / *0.8 1.2 / *0.9
6GT2 812-0GB08 RF650A, circular, (all readers) (118 / *79) (236 / *157) (157 / *126) (47 / *31) (47 / *35)
6GT2 812-1AA08 RF662A circular, (all readers)
6GT2 812-2GB08 RF680A, switchable (all readers) 198 x 198 x 60

** 3-way
20 mm Spacer
mounting kit (6GT2 190-0AA00) Spacer Spacer
Accessories (6GT2 890-2AB10) Fixing pocket (6GT2 898-2AA00) (6GT2 898-3AA00)
*** mounting plate (6GT2 190-0AB00)
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch)


* Use this value in combination with RF650R
48 Unrestricted | © Siemens 2023 | All rights reserved. pay attention to the system manual for range overshoot

SIMATIC Ident Configuration Guide


RF680T RF682T
RF600 Antennas RF640T RF645T
6GT2 810-2HG81 6GT2810-3HG81
RF683T
6GT2 810-2DC00 (ETSI) 6GT2 810-2HC05 6GT2 810-3HG00
Family Matrix 6GT2 810-2DC10 (FCC)
96/240 bit EPC,
448 bit EPC, 96/240 bit EPC,
64 byte
224 bit EPC,
384 byte
256 bit EPC,
32 byte
256 byte
64 byte
865-868 MHz (ETSI)
902-928 MHz (FCC)
Passive Tags (with Gen2
protocol) Operational Temperature Range -40°C to 125°C -40°C to 85°C -40°C to 220°C -40°C to 220°C -40°C to 220°C
Dimensions ( L x W x D) mm Ø 50 x 8 52 x 36 x 12,5 130 x 32 x 15 130 x 32 x 15 130 x 32,6 x 16,5
Ingress Protection (IP) Rating
IP68/ IPx9K IP68 IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K

RF685R** (IP65)
(internal antenna used)
6GT2 811-6CA10-0AA0 (ETSI) Integrated 3.5 6.0 5.0 4.0 4,5
6GT2 811-6CA10-1AA0 (FCC) (138) (236) (197) (157) (177)
6GT2 811-6CA10-2AA0 (CMIIT) 260 x 193 x 52
6GT2 811-6CA10-4AA0 (ARIB)

RF615A***
RF685R** (IP65)
(external antenna used) 0.8 / *0.6 1.8 / *1.2 1.4 / *1.0 1.0 / *0.7 0,6
(31 / *24) (71 / *47) (55 / *39) (39 / *28) (24)
6GT2 811-6CA10-0AA0 (ETSI)
52 x 52 x 16
6GT2 811-6CA10-1AA0 (FCC)
6GT2 811-6CA10-2AA0 (CMIIT) RF622A***
6GT2 811-6CA10-4AA0 (ARIB) 1.0 / *0.7 2.0 / *1.4 1.6 / *1.2 1.2 / *0.8 0,6
(39 / *28) (79 / *55) (63 / *47) (47 / *31) (24)
RF680R** (IP65) 75 x 75 x 20
6GT2 811-6AA10-0AA0 (ETSI) RF642A**
6GT2 811-6AA10-1AA0 (FCC) 4.0 / *2.5 6.0 5.0 4.5 8,0
6GT2 811-6AA10-2AA0 (CMIIT)
(157 / *98) (236) (197) (177) (315)
6GT2 811-6AA10-4AA0 (ARIB)
185 x 185 x 45
RF650A**
RF650R** (IP30) 2.5 / *2.0 5.0 / *3.5 4.0 / *3.0 2.5 / *2.0 4,5 / *3,0
6GT2 811-6AB20-0AA0 (ETSI) (98 / *79) (197 / *138) (157 / *118) (98 / *79) (177 / *118)
6GT2 811-6AB20-1AA0 (FCC)
198 x 198 x 60
6GT2 811-6AB20-2AA0 (CMIIT)
6GT2 811-6AB20-4AA0 (ARIB) RF662 A
3.0 / *2.0 5.0 4.5 4.0 7,0
Antennas: (118 / *79) (197) (177) (157) (275)
6GT2 812-0EA00 RF615A, linear, (ETSI) 312 x 312 x 68
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT, ARIB)
6GT2 812-2EA00 RF622A, linear, (ETSI) RF680A**
6GT2 812-2EA01 RF622A, linear, (FCC, CMIIT, ARIB)
6GT2 812-1GA08 RF642A, linear, (all readers) 3.0 /*2.0 4.5 / *3.0 4.5 / *3.0 3.0 / *2.0 4,0
6GT2 812-0GB08 RF650A, circular, (all readers) (118 / *79) (177 / *118) (177 /*118) (118 / *79) (157)
6GT2 812-1AA08 RF662A circular, (all readers)
6GT2 812-2GB08 RF680A, switchable (all readers) 198 x 198 x 60

** 3-way
mounting kit Mounting cover 6GT2898-5AA00
Retaining bracket Retaining bracket
Accessories (6GT2 890-2AB10) Retaining bracket 6GT2890-2AA00 6GT2890-2AA00
*** mounting plate 6GT2898-5AB00
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch)


* Use this value in combination with RF650R
49 Unrestricted | © Siemens 2023 | All rights reserved. pay attention to the system manual for range overshoot

SIMATIC Ident Configuration Guide


RF600
System Interfaces

50 Unrestricted | © Siemens 2023 | All rights reserved.


RF600 Reader Labels
RF630L
System Interfaces 6GT2 810-2AE82-xxxx
6GT2 810-2AE83-1AX0
6GT2810-2AB04-0AX1
6GT2810-2AC84
RF610R 6GT2810-2AE83-0AX1
6GT2 810-2AE81-0AX3
(only internal antenna)
RF642L
PROFINET & OPC UA & Ethernet/IP & TCP/IP 6GT2811-6BC10-0AA0 (ETSI)
6GT2811-6BC10-1AA0 (FCC)
6GT2811-6BC10-2AA0
6GT2 810-3AC00 (ETSI)
6GT2 810-3AC10 (FCC)
(CMIIT) RF682L

+ Direct connection

Ethernet /PN Cable M12


+ Connection
6GT2810-2AG84-0AX2
RF690L
6GT2 810-2AG00 (ETSI)
6GT2 810-2AG10 (FCC)
length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required)
with external
power supply
Tags
RF615R
(internal antenna and
Network Connection via Switch RF610T
optional 1 ext. antenna)
Controller Library and 6GT2 810-2BB80

Demo-Software on DVD
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + Ethernet /PN Cable M12
+ Power supply
6GT2811-6CC10-0AA0 (ETSI)
6GT2811-6CC10-1AA0 (FCC)
External antennas:
6GT2811-6CC10-2AA0
(CMIIT) RF620T
length from 2 to 15 m available EU connector RF615A 6GT2 810-3HC80
6GT2 898-0AC00 6GT2 812-0EA00; ETSI RF621T
e.g. 2 m = 6XV1871-5TH20
UK connector 6GT2 812-0EA01; FCC, etc. 6GT2810-3HG81
6GT2 898-0AC10 RF622A
General host application as IE switch SCALANCE X US connector 6GT2812-2EA00, ETSI
a, XML client (6GK5 …) 6GT2 898-0AC20 6GT2812-2EA01, FCC, etc. RF625T
b, Off-the-shelf third-party RFID Middleware cable 24 V for power supply 6GT2 810-2EE00 (ETSI)
5 m = 6GT2 891-0PH50
RF642A 6GT2 810-2EE01 (FCC)
c, OPC UA for AutoID Client 6GT2 812-1GA08
Controller Application written in cable w/ open ends
any controller language using Ident library 2 m = 6GT2 891-4EH20 RF650A
5 m = 6GT2 891-4EH50 6GT2 812-0GB08
with Ident profile RF630T
RF662A 6GT2 810-2EC00 (ETSI)
6GT2 812-1AA08 6GT2 810-2EC10 (FCC)
RF680A
6GT2 812-2GB08
Antenna Cable
1m = 6GT2815-0BH10 RF640T Gen2
3m = 6GT2 815-0BH30 6GT2 810-2DC00 (ETSI)
5m, flex = 6GT2 815-2BH50 6GT2 810-2DC10 (FCC)

A maximum of 2 readers may be connected 10m,2dB = 6GT2 815-1BN10


PROFIBUS + 10m,4dB = 6GT2 815-0BN10
15m,flex = 6GT2 815-2BN15
RF166C to RF6x0R RF645T
20m = 6GT2 815-0BN20 6GT2 810-2HC05
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 40m = 6GT2 815-0BN40
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
Powered through Power Splitter
50 m = 6GT2 891-4FN50* connection cable 6GT2 890-0BC00 RF680T
DI/DO interface 6GT2 810-2HG81
Use a M12 A-coded connector
Reader connector 90° angled
3RK1902-4BA00-5AA0
RF682T
2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 6GT2 810-3HG81
Cover caps
RF166C (DP-V1) 10 m = 6GT2 891-4JN10 6GT2898-4AA10 RF683T
Communication Module Opt.: 3-way mounting kit 6GT2 810-3HG00
(6GT2 002-0EE20) 6GT2890-2AB10
Opt.: Mounting plate
6GT2890-2AC00

51 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF600 Reader Labels
RF630L
System Interfaces Direct connection
+ RF650R Ethernet Connection Cable
0.5 to 50 m available; e.g. 2 m = 6XV1870-3QH20 (no switch required)
+ with external power supply
RF615A
6GT2 812-0EA00; ETSI
6GT2 810-2AE82-xxxx
6GT2 810-2AE83-1AX0
6GT2810-2AB04-0AX1
6GT2810-2AC84
6GT2 812-0EA01; FCC, etc.
Ethernet TCP/IP RF622A
6GT2810-2AE83-0AX1
6GT2 810-2AE81-0AX3

Network Connection via Switch 6GT2812-2EA00, ETSI RF642L


6GT2812-2EA01, FCC, etc. 6GT2 810-3AC00 (ETSI)
Demo-Software
on DVD + length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + RF650R Ethernet Connection Cable
+ RF642A
6GT2 812-1GA08
6GT2 810-3AC10 (FCC)
RF682L
6GT2810-2AG84-0AX2
0.5 to 50 m available RF650A RF690L
e.g. 2 m = 6XV1870-3QH20 6GT2 812-0GB08 6GT2 810-2AG00 (ETSI)
6GT2 810-2AG10 (FCC)
IE Switch SCALANCE X RF650R RF662A
Host application as (6GK5 …) (1 to 4 ext. antennas)
a, XML client
6GT2 812-1AA08
Tags
b, Off-the-shelf third-party RFID Middleware 6GT2811-6AB20-0AA0 (ETSI) RF680A
6GT2811-6AB20-1AA0 (FCC) 6GT2 812-2GB08
c, OPC UA for AutoID Client 6GT2811-6AB20-2AA0 (CMIIT)
6GT2811-6AB20-4AA0 (ARIB) Antenna Mounting kit RF610T
6GT2 890-2AB10 6GT2 810-2BB80

Antenna Cable
1m = 6GT2815-0BH10 RF620T
3m = 6GT2 815-0BH30 6GT2 810-3HC80
5m, flex = 6GT2 815-2BH50 RF621T
10m,2dB = 6GT2 815-1BN10 6GT2810-3HG81
PROFINET & OPC UA & Ethernet/IP & TCP/IP 10m,4dB
15m,flex
= 6GT2 815-0BN10
= 6GT2 815-2BN15
20m = 6GT2 815-0BN20
40m = 6GT2 815-0BN40 RF625T
6GT2 810-2EE00 (ETSI)
RF680R Power Splitter 6GT2 810-2EE01 (FCC)

+ Direct connection
Ethernet /PN Cable M12 + (1 to 4 ext. antennas)
6GT2811-6AA10-0AA0 (ETSI)
6GT2811-6AA10-1AA0 (FCC)
6GT2 890-0BC00
(do not use with RF680A)

Power supply
length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required) 6GT2811-6AA10-2AA0 (CMIIT)
RF630T
6GT2811-6AA10-4AA0 (ARIB)
EU connector 6GT2 810-2EC00 (ETSI)
6GT2 898-0AC00 6GT2 810-2EC10 (FCC)

UK connector
Network Connection via Switch 6GT2 898-0AC10
Controller Library and US connector
Demo-Software on DVD
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + Ethernet /PN Cable M12
+ 6GT2 898-0AC20
cable 24 V for power supply
RF640T Gen2
6GT2 810-2DC00 (ETSI)
6GT2 810-2DC10 (FCC)

length from 2 to 15 m available 5 m = 6GT2 891-0PH50


e.g. 2 m = 6XV1871-5TH20 cable w/ open ends
2 m = 6GT2 891-4EH20 RF645T
General host application as RF685R 5 m = 6GT2 891-4EH50 6GT2 810-2HC05
IE switch SCALANCE X (internal antenna and
a, XML client optional
(6GK5 …)
b, Off-the-shelf third-party RFID Middleware optional 1 ext. antenna)
DI/DO cable 5m
RF680T
c, OPC UA for AutoID Client 6GT2811-6CA10-0AA0 (ETSI) 6GT2 810-2HG81
6GT2891-0CH50
Controller Application written in 6GT2811-6CA10-1AA0 (FCC) RF682T
3-way mounting kit
any controller language using Ident library 6GT2811-6CA10-2AA0 (CMIIT)
6GT2890-2AB10
6GT2 810-3HG81
with Ident profile 6GT2811-6CA10-4AA0 (ARIB) RF683T
Mounting plate
6GT2890-2AC00 6GT2 810-3HG00

Cover caps Rail mounting set


(6GT2898-4AA10) 6GT2890-0AB00

52 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF600 Reader Labels
RF630L
System Interfaces powered through connection cable 6GT2 810-2AE82-xxxx
6GT2 810-2AE83-1AX0
6GT2810-2AB04-0AX1
6GT2810-2AC84
RF615A
PROFIBUS 6GT2 812-0EA00; ETSI
6GT2 812-0EA01; FCC, etc.
6GT2810-2AE83-0AX1
6GT2 810-2AE81-0AX3
RF642L
RF622A 6GT2 810-3AC00 (ETSI)
6GT2812-2EA00, ETSI 6GT2 810-3AC10 (FCC)
6GT2812-2EA01, FCC, etc. RF682L
6GT2810-2AG84-0AX2
A maximum of 2 readers may be connected RF642A RF690L
+ RF166C to RF6x0R
6GT2 812-1GA08
RF650A
6GT2 810-2AG00 (ETSI)
6GT2 810-2AG10 (FCC)

6GT2 812-0GB08
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
RF680R RF662A Tags
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 (1 to 4 ext. antennas) 6GT2 812-1AA08
50 m = 6GT2 891-4FN50* 6GT2811-6AA10-0AA0 (ETSI)
6GT2811-6AA10-1AA0 (FCC) RF680A
6GT2811-6AA10-2AA0 (CMIIT) 6GT2 812-2GB08 RF610T
Reader connector 90° angled 6GT2 810-2BB80
2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 6GT2811-6AA10-4AA0 (ARIB)
10 m = 6GT2 891-4JN10
Antenna Cable
RF620T
1m = 6GT2815-0BH10 6GT2 810-3HC80
RF166C (DP-V1) 3m = 6GT2 815-0BH30 RF621T
Communication Module 5m, flex = 6GT2 815-2BH50 6GT2810-3HG81
(6GT2 002-0EE20) 10m,2dB = 6GT2 815-1BN10
10m,4dB = 6GT2 815-0BN10
15m,flex = 6GT2 815-2BN15
20m = 6GT2 815-0BN20 RF625T
40m = 6GT2 815-0BN40 6GT2 810-2EE00 (ETSI)
6GT2 810-2EE01 (FCC)
RF685R Power Splitter
(internal antenna and 6GT2 890-0BC00
optional 1 ext. antenna) (do not use with RF680A)

6GT2811-6CA10-0AA0 (ETSI) RF630T


6GT2811-6CA10-1AA0 (FCC) 6GT2 810-2EC00 (ETSI)
6GT2 810-2EC10 (FCC)
6GT2811-6CA10-2AA 0 (CMIIT)
6GT2811-6CA10-4AA0 (ARIB)

Cover caps RF640T Gen2


6GT2 810-2DC00 (ETSI)
(6GT2898-4AA10)
6GT2 810-2DC10 (FCC)

optional
DI/DO cable 5m RF645T
6GT2891-0CH50 6GT2 810-2HC05

3-way mounting kit


6GT2890-2AB10 RF680T
6GT2 810-2HG81
Mounting plate RF682T
6GT2890-2AC00 6GT2 810-3HG81
RF683T
Rail mounting set 6GT2 810-3HG00
6GT2890-0AB00

53 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF1000
Family Matrix
13.56 MHz – passive tags

54 Unrestricted | © Siemens 2023 | All rights reserved.


RF1000 D100 D200 D400 D124 D324 D424 D524 D226s D426s
6GT2 600-0AD10 6GT2 600-1AD00 -0AX0 6GT2 600-4AD00 2 6GT2 600-0AC10 6GT2 600-3AC00 6GT2 600-4AC00 6GT2 600-5AC00
Family Matrix 112 byte EEPROM 256 byte EEPROM kbyte FRAM 112 byte EEPROM 992 byte EEPROM 2 kbyte FRAM 8 kByte FRAM
6GT2600-2BA00
316 byte EEPROM
6GT2600-4BA00
2000 byte FRAM

13.56 MHz
Passive Tags -20°C to 60°C -20°C to 60°C
-25°C to 80°C -40°C to 180°C -40°C to 140°C -40°C to 100°C
85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8 -40°C to 100°C -40°C to 90°C -40°C to 90°C
Ø 27 x 4 Ø 27 x 4 Ø 27 x 4
IP68 IP67 IP67 Ø 27 x 4 Ø 30 x 3 IP68 Ø 30 x 3
Operational temperature range IP68/ IPx9K IP67 IP67/ IPx9K
IP67 / IPx9k IP68
Dimensions (L x W x D) mm
Ingress Protection (IP) rating

RF1040R (USB, RS232) 30 30 30 10 10 10 10 10 10


6GT2831-6CA50 (1.18) (1.18) (1.18) (0.39) (0.39) (0.39) (0.39) (0.39) (0.39)

RF1060R (USB) 30 30** 30 10 10 10 10 10 10


6GT2831-6AA50 (1.18) (1.18) (1.18) (0.39) (0.39) (0.39) (0.39) (0.39) (0.39)

RF1070R (USB, RS232)


6GT2831-6BA50 30 30 10 10 10 10
6GT2831-6BA50-0AX0 (OEM*) (1.18) (1.18) (0.39) (0.39) (0.39) (0.39)

RF1140R
6GT2831-6CB00 30 30 30 10 10 10 10 10 10
(XML / Modbus-TCP) (1.18) (1.18) (1.18) (0.39) (0.39) (0.39) (0.39) (0.39) (0.39)

RF1170R
6GT2831-6BB00
(XML / Modbus-TCP)
30 30 10 10 10 10
(1.18) (1.18) (0.39) (0.39) (0.39) (0.39)

Maximum Distance for Stationary Tag (mm)


55 Unrestricted | © Siemens 2023 | All rights reserved. Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF1000 D126 D426 D526 E600 E611 ISO 14443 Legic 125 kHz (LF)
6GT2 600-0AE00 6GT2 600-4AH00 6GT2 600-5AH00 6GT2 300-0AA00 6GT2 300-0BB00
Family Matrix 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 752 byte EEPROM 752 byte EEPROM

13.56 MHz and


Company badges Company badges Company badges
125 kHz passive tags -40°C to 100°C and transponders and Transponders and Transponders
-40°C to 100°C -40°C to 100°C -25°C to 60°C -40°C to 85°C acc. Legic Prime acc. Hitag 1/2/S
acc. ISO 14443 A/B
Ø 50 x 3.6 Ø 50 x 3.6 Ø 50 x 3.6 86 x 54 x 0.76 86 x 54 x 2.5 and Legic Advant EM41xx, EKS and more
Operational temperature range IP68 IP68 IP68 IP68 IP67
Dimensions (L x W x D) mm
Ingress Protection (IP) rating

RF1040R (USB, RS232) 30 30 30 30 30 30 30


6GT2831-6CA50 (1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.18)

RF1060R (USB) 30 30 30 30 30 30
6GT2831-6AA50 (1.18) (1.18) (1.18) (1.18) (1.18) (1.18)

RF1070R (USB, RS232)


6GT2831-6BA50 30 30 30 30 30
6GT2831-6BA50-0AX0 (OEM*) (1.18) (1.18) (1.18) (1.18) (1.18)

RF1140R
30 30 30 30 30 30 30
6GT2831-6CB00 (XML / Modbus-TCP) (1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.18)

RF1170R
6GT2831-6BB00 30 30 30 30 30
(XML / Modbus-TCP) (1.18) (1.18) (1.18) (1.18) (1.18)

Maximum Distance for Stationary Tag (mm)


56 Unrestricted | © Siemens 2023 | All rights reserved. Maximum Distance for Stationary Tag (inch)

SIMATIC Ident Configuration Guide


RF1000
System Interfaces

57 Unrestricted | © Siemens 2023 | All rights reserved.


RF1000 Reader Tags
System Interfaces powered through connection cable

Optional
Ethernet TCP/IP or Modbus TCP (PoE): 100MB D100 (6GT2 600-0AD10)
D200 (6GT2 600-1AD00 -0AX0)
D400 (6GT2 600-4AD00)*

D124 (6GT2 600-0AC10)


RF1100T HID Lizenz: D324 (6GT2 600-3AC00)
D424 (6GT2 600-4AC00)*
Network Connection via SCALANCE Switches PoE 6GT2300-0CC00-0AX1 D524 (6GT2 600-5AC00)*

PC RF1140R
(6GT2831-6CB00)
Use XML Commands
or Modbus TCP
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
D126 (6GT2 600-0AE00)
D426 (6GT2 600-4AH00)*
D526 (6GT2 600-5AH00)*

IE switch SCALANCE X108 PoE


(6GK5108-0PA00-2AA3) Card holder
6GT2 890-0CA00
or D226s (6GT2600-2BA00)
D426s (6GT2600-4BA00)

S7-1200 CPU
length from Company badges and
Use Modbus TCP 0.5 to 50 m available transponders
e.g. 2 m = 6XV1870-3QH20 acc. ISO 14443 A/B
Incl. MDS E600/E611

IE switch SCALANCE XC208G PoE


(e.g. 6GK5208-0RA00-2AC2)
Cleanroom cap
(no usage with card holder)
or Transponders
acc. ISO 15693

S7-1500 CPU length from **)


Or 0.5 to 50 m available
3rd Party PLC e.g. 2 m = 6XV1870-3QH20
Company badges
IE switch SCALANCE XR326-2C PoE WG for control cabinet mount and Transponders
(e.g. 6GK5326-2QS00-3AR3) 6GT2890-0CD00 ***** acc. Legic Prime
Use Modbus TCP
and Legic Advant

Example LOGO! with Modbus:


https://support.industry.siemens.com/cs/ww/en/view/109823376
***)
Company badges
Example S7-1500 / S7-1200 with Modbus: and Transponders
https://support.industry.siemens.com/cs/ww/en/view/109816534 acc. Hitag 1/2/S,
EM41xx, EKS and more
LOGO! New Example XML Demo Applikation for PC Integration: Tag restrictions:
Use Modbus TCP https://support.industry.siemens.com/cs/ww/en/view/109824195 * not for RF1170R
** only with RF1170R
*** only with RF1140R

58 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF1000 Reader Tags
System Interfaces Powered through USB cable

Optional:
USB D100 (6GT2 600-0AD10)
D200 (6GT2 600-1AD00 -0AX0)
D400 (6GT2 600-4AD00)*

Card holder
6GT2 890-0CA00
1 Reader per USB port type A D124 (6GT2 600-0AC10)
D324 (6GT2 600-3AC00)
D424 (6GT2 600-4AC00)*
(USB cable 1.8 m included) D524 (6GT2 600-5AC00)*

Config–Card
(for customer-specific
Optional: short USB cable RF1040R reader configuration)

+
D126 (6GT2 600-0AE00)
(6GT2 831-6CA50) 6GT2300-0CC00-0AX0 D426 (6GT2 600-4AH00)*
0.5 m = 6GT2 891-0UE50 D526 (6GT2 600-5AH00)*

Extension unit IP65 D226s (6GT2600-2BA00)


for operator controls D426s (6GT2600-4BA00)

DLL and simple Demo for PC: 12’’ 6AV7674-1LA31-0AA0


https://support.industry.siemens.com/cs/ww/en/view/109741590
15’’ 6AV7674-1LA41-0AA0
Company badges and
Local user administration for 19’’ 6AV7674-1LA51-0AA0 transponders
RF1060R 22’’ 6AV7674-1LA61-0AA0 acc. ISO 14443 A/B
Comfort Panels and IPC: (6GT2 831-6AA50) Incl. MDS E600/E611
https://support.industry.siemens.com/cs/de/en/view/109754400
(included in SIMATIC HMI Option+)

Central user management PM Logon Housing for desktop


https://www.siemens.com/pm-logon Transponders
https://support.industry.siemens.com/cs/ww/en/view/109779685 and wall mounting acc. ISO 15693
6GT2890-0CB00
**)
SIMATIC Logon / Logon Remote Access
https://support.industry.siemens.com/cs/ww/en/view/109749167 Cleanroom cap
Company badges
(no usage with card holder) and Transponders
RF1070R acc. Legic Prime
and Legic Advant
(6GT2 831-6BA50)
(6GT2 831-6BA50-0AX0,
OEM )
for wall mount
6GT2890-0CC00
***)
requires 6GT2890-0CB00 Company badges
and Transponders
acc. Hitag 1/2/S,
EM41xx, EKS and more

Tag restrictions:
for control cabinet mount * not for RF1170R
6GT2890-0CD00 ** only with RF1170R
*** only with RF1140R

59 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF1000 Reader Tags
System Interfaces Powered through connection cable

Optional:
PROFINET & Ethernet/IP D100 (6GT2 600-0AD10)
D200 (6GT2 600-1AD00 -0AX0)
D400 (6GT2 600-4AD00)*
Communication Modules
A maximum of Card holder
6GT2 890-0CA00
1 reader at RF185C, D124 (6GT2 600-0AC10)
2 readers at RF186C/CI, RF188C/CI D324 (6GT2 600-3AC00)
D424 (6GT2 600-4AC00)*
of RF1000 may be connected (RS232) D524 (6GT2 600-5AC00)*

RF185C RF186C RF188C


(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40)
+ Connection cable:
+ RF1040R
Config–Card
(for customer-specific
2m = 6GT2891-4UH20 (6GT2 831-6CA50) reader configuration) D126 (6GT2 600-0AE00)
6GT2300-0CC00-0AX0 D426 (6GT2 600-4AH00)*
(do not use an additional D526 (6GT2 600-5AH00)*
extension cable)
Additional IOs
Extension unit IP65 D226s (6GT2600-2BA00)
for operator controls D426s (6GT2600-4BA00)

Types of IO-Link 12’’ 6AV7674-1LA31-0AA0

+ RF18xCI to sensor
+ IO module
IO-extension module
15’’
19’’
6AV7674-1LA41-0AA0
6AV7674-1LA51-0AA0
Company badges and
transponders
RF186CI RF188CI Sensor cable from 6ES7 14….. (up to 8xDI + 8xDO) 22’’ 6AV7674-1LA61-0AA0 acc. ISO 14443 A/B
0.5 to 15 m available Incl. MDS E600/E611
(6GT2 002-0JE50) (6GT2 002-0JE60)
(e.g. 2 m = 6XV1801-2CH20) See page 88 for detailed information
RF1070R
(6GT2 831-6BA50)
(6GT2 831-6BA50-0AX0,
OEM)
Or one Housing for desktop
Transponders
Standard sensor and wall mounting acc. ISO 15693
6GT2890-0CB00
Or one **)
Actor
Cleanroom cap
(no usage with card holder) Company badges
and Transponders
acc. Legic Prime
and Legic Advant

PROFIBUS A maximum of 2 readers


may be connected (RS232)

+ Connection cable:
2m = 6GT2891-4UH20
+ for wall mount
6GT2890-0CC00
requires 6GT2890-0CB00 Company badges
and Transponders
***)

acc. Hitag 1/2/S,


EM41xx, EKS and more
(do not use an additional
extension cable) Tag restrictions:
for control cabinet mount * not for RF1170R
RF166C (DP-V1) 6GT2890-0CD00
** only with RF1170R
Communication Module
(6GT2 002-0EE20) *** only with RF1140R

60 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF1000 Reader Tags
System Interfaces Powered through connection cable

Optional:
SIMATIC PLC D100 (6GT2 600-0AD10)
A maximum of 1 readers may be connected
S7-1200 + RF120C to RF10x0R
2 m = 6GT2891-6UH20
+ Card holder
D200 (6GT2 600-1AD00 -0AX0)
D400 (6GT2 600-4AD00)*

6GT2 890-0CA00
D124 (6GT2 600-0AC10)
D324 (6GT2 600-3AC00)
RF120C D424 (6GT2 600-4AC00)*
D524 (6GT2 600-5AC00)*
6GT2 002-0LA00
Up to 3 x RF120C modules Config–Card
per S7-1200 rack RF1040R (for customer-specific
(6GT2 831-6CA50) reader configuration) D126 (6GT2 600-0AE00)
6GT2300-0CC00-0AX0 D426 (6GT2 600-4AH00)*

ET 200pro ET 200pro PROFIBUS DP-V1


D526 (6GT2 600-5AH00)*

Interface Modul A maximum of 2 readers


via PROFIBUS may be connected (RS232) Extension unit IP65
+ +
D226s (6GT2600-2BA00)

or PROFINET ET 200pro PROFINET


Interface Modul + for operator controls
12’’ 6AV7674-1LA31-0AA0
D426s (6GT2600-4BA00)

or S7 PLC Connection cable:


2m = 6GT2891-4UH20 15’’ 6AV7674-1LA41-0AA0
ET 200pro PROFINET RF170C 19’’ 6AV7674-1LA51-0AA0
Company badges and
transponders
CPU module Communication module (do not use an additional
(6GT2002-0HD01)
22’’ 6AV7674-1LA61-0AA0 acc. ISO 14443 A/B
Up to 9 x RF170C extension cable) Incl. MDS E600/E611
Use standard function Connection block
modules per (6GT2002-1HD01) RF1070R
block Ident Profile ET 200pro rack (6GT2 831-6BA50)
(6GT2 831-6BA50-0AX0,
Application example available:
OEM)
https://support.industry.siemens.com/cs/ww/de/view/109770535 Housing for desktop
Transponders
and wall mounting acc. ISO 15693
6GT2890-0CB00

ET 200SP via serial modul Cleanroom cap


**)

(example; also useful for the connection to other serial modules) (no usage with card holder) Company badges
and Transponders
acc. Legic Prime
and Legic Advant
Serial interface RS232
6ES7137-6AA00-0BA0
for wall mount
A maximum of 1 reader per serial module 6GT2890-0CC00
requires 6GT2890-0CB00 ***)
Company badges
may be connected (RS232) and Transponders

+ Connection cable:
3m = 6GT2891-2UH30
+ acc. Hitag 1/2/S,
EM41xx, EKS and more

Tag restrictions:
for control cabinet mount
LOGO POWER 220V/5V (do not use an additional 6GT2890-0CD00
* not for RF1170R
** only with RF1170R
Use : P2P_Send and P2P_Receive 6EP3310-6SB00-0AY0 extension cable)
*** only with RF1140R
for programming The max. current of 3 A may supply up to 10 Reader

61 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


SIMATIC RF HANDHELDS

62 Unrestricted | © Siemens 2023 | All rights reserved.


SIMATIC RF Handhelds
Handheld (w/o Reading Head) Additional Components Spare Parts

Docking / Spare Battery for


Mobile Reader Basic Device for HF and UHF Reading head with user software and rechargeable Pistol Grip
Charging Unit RF160B
battery (without charging / docking unit) 6GT2093-0FG00
6GT2003-0FB00 6GT2093-0FA00

SIMATIC RF160B
6GT2003-0FA00
UHF HEAD HF HEAD

Mobile Reader Basic Device for HF and UHF Reading head with user Software and rechargeable battery (without charging / docking station)

UHF Head ETSI (6GT2813-1FA00) HF Head with int Antenna


(6GT2803-1FA00)

UHF Head FCC (6GT2813-1FA10)

HF Head for Antenna


(6GT2803-1FA10)

UHF Head CMIIT (6GT2813-1FA20)

63 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


SIMATIC RF Handheld WITH EXT ANTENNA
HF HEAD

External Antenna
Antenna MLFB Suitable for
without cable

Ant 3 6GT2 398-1CD30-0AX0 D124, D160, D324, D422, D423, D424, D425, D428,
D460, D522, D524, D525, D528, E624,
RF320T, RF330T, RF340T, RF350T, RF360T

Ant 3S 6GT2 398-1CD50-0AX0 D117, D127, D421, D521

Ant 8 6GT2 398-1CF00 D117, D127, D421000

Ant 12 ** 6GT2 398-1DC00 D117, D127, D160, D421, D428, D460, D521, D528,
E623,
HF Head for Antenna RF330T

(6GT2803-1FA10) Ant 18 ** 6GT2 398-1DA00 D117, D124, D127, D160, D226s, D324, D421, D422,
D424, D425, D426s, D428, D460, D521, D522, D524,
D525, D528, E623, E624
RF320T, RF330T, RF340T

Ant 30 6GT2 398-1DD00 D124, D126, D160, D226s, D324, D422, D423, D424,
D425, D426, D426s, D428, D460, D522, D524, D525,
D526, D528, E624,
RF320T, RF330T, RF340T, RF350T, RF360T

Antenna cables MLFB Suitable for

0.1 m 6GT2 898-0EA00 For all antenna types above


0.6 m 6GT2 391-0AE60 Only for antennas marked64 with **
3m 6GT2 391-0AH30 For all antenna types above

64 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


SIMATIC IDENT
Conveyor Belt Gate

65 Unrestricted | © Siemens 2023 | All rights reserved.


SIMATIC IDENT CB Gates
SIMATIC IDENT CB 2H Gate SIMATIC IDENT CB 2H Gate CC SIMATIC IDENT CB 2H Gate CMIIT SIMATIC IDENT CB 4 Gate SIMATIC IDENT CB 4H Gate

RFID federated band detection system RFID federated band detection system RFID federated band detection system RFID federated band detection system RFID federated band detection system
with one reading point and two antennas with one reading point and two antennas with one reading point and two antennas with one reading point and two antennas with one reading point and four antennas
(top) for easy coverage. Frequency (top) for easy coverage. Frequency (top) for easy coverage. Frequency (top) for easy coverage. Frequency (top and bottom) for double-sided
range ETSI range FCC range CMIIT range ETSI. Without panel display. coverage. Frequency range ETSI

MLFB: MLFB: MLFB: MLFB: MLFB:


6GT2881-1AB02-0AA0 6GT2881-1AB02-1AA0 6GT2881-1AB02-2AA0 6GT2881-1AA04-0AA0 6GT2881-1AB04-0AA0

SIMATIC IDENT CB 4H Gate FCC SIMATIC IDENT CB 4H Gate CMIIT SIMATIC IDENT CB 4H Gate for SIMATIC IDENT CB 4H Gate FCC SIMATIC IDENT CB 4H Gate CMIIT
Tire for Tire for Tire

RFID federated band detection system with RFID federated band detection system with RFID federated band detection system with RFID federated band detection system with RFID federated band detection system with
one reading point and four antennas (top and one reading point and four antennas (top and two reading points and four antennas (top and two reading points and four antennas (top and two reading points and four antennas (top and
bottom) for double-sided coverage. bottom) for double-sided coverage. bottom) for double-sided coverage optimized bottom) for double-sided coverage optimized bottom) for double-sided coverage optimized
Frequency range FCC Frequency range CMIIT for tag position discrimination (top or bottom) for tag position discrimination (top or bottom) for tag position discrimination (top or bottom)
in a tire. Frequency range ETSI in a tire. Frequency range FCC in a tire. Frequency range CMIIT

MLFB: MLFB: MLFB: MLFB: MLFB:


6GT2881-1AB04-1AA0 6GT2881-1AB04-2AA0 6GT2881-1AB04-0AB0 6GT2881-1AB04-1AB0
6GT2881-1AB04-2AB0

66 Unrestricted | © Siemens 2023 | All rights reserved. Link zu SIOS: https://support.industry.siemens.com/cs/us/en/view/109823734

SIMATIC Ident Configuration Guide


MV500
System Interfaces

67 Unrestricted | © Siemens 2023 | All rights reserved.


MV500 Reader Options
System Interfaces Direct connection
+ MV500 Ethernet Connection Cable
length from 2 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
+ With external power supply
DO
(no switch required) Wires included in
Ethernet TCP/IP power supply cable
Network Connection via Switch „Open wires“

Use native TCP/IP


with text based
+ + + MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ Software
commands IP 20: IE switch SCALANCE X (6GK5 …) e.g. 2 m 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
Pat-Genius
or 6GF3400-0SL03
MV530
MV500 Ethernet Connection Cable
IP 65: IE switch SCALANCE XP208 length form 0.3 m to15 m available
S; 800 x 600 pixel:
(6GK5208-0HA00-2AS6) (6GF3530-0CD10)
e.g. 2 m = 6XV1870-8GH20 H; 1280 x 1024 pixel:
(6GF3530-0GE10) Micro SD Card
for Configuration

S7-1200 via Industrial Ethernet or PROFINET Backup; 4GB


6GK6000-8HT01-0SA2

Cable for power


+ Direct connection (1 reader may be connected)
MV500 Ethernet Connection Cable
length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
+ supply
Open wires
Support
Mounting plate
(no switch required) 10 m = 6GF3500-8BA21 6GF3440-8CA
10 m UL = 6GF3500-8BA23 Tri-plate
30 m = 6GF3500-8BA41 6GF9002-7AD
Network Connection via Compact Switch Module 30 m UL = 6GF3500-8BA43

S7-1200 CPU
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + A maximum of 3 readers may be connected)
MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ or
CSM 1277 e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
Power supply
(6GK7 277-1AA10-0AA0)
Use library “Ident Profile” EU connector
6GT2 898-0AA00

UK connector
6GT2 898-0AA10

S7-300/1500 via Direct connection (1 reader may be connected) US connector

Industrial + MV500 Ethernet Connection Cable


length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
+ 6GT2 898-0AA20

cable for 24 V
(no switch required) 5 m = 6GT2 891-0PH50
Ethernet or +
S7-1500 CPU Network Connection via Compact Switch Module 50 cm = 6GF3500-8BA11
PROFINET or
5 m = 6GF3500-8BA12

A maximum of 3 readers may be connected


+
S7-300 CPU
or
S7-300 with CP343-1
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+
e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
Use library “Ident Profile” CSM 377
(6GK7 377-1AA00-0AA0) ³) Custom assembly necessary; use the correct stripping tool

68 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
System Interfaces Direct connection
+ MV500 Ethernet Connection Cable
length from 2 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
+ With external power supply DO
Wires included in
(no switch required) power supply cable
Ethernet TCP/IP 6 mm:
Manual focus lens
6GF9001-1BB01 s)
„Open wires“
Network Connection via Switch 8.5 mm: 6GF9001-1BE01 sh) 1)
Software

+
12 mm: 6GF9001-1BL01 sh)

Use native TCP/IP


with text based
+ + + MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
MV540
S; 800 x 600 pixel:
(6GF3540-0CD10)
12 mm:
16 mm:
16 mm:
6GF3560-8EA01-0FF0 ux) 1)
6GF9001-1BF01 4)

6GF3560-8EA02-0FF0 sh)
Veri-Genius
6GF3400-0SL02
Pat-Genius
commands IP 20: IE switch SCALANCE X (6GK5 …) e.g. 2 m 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) H; 1280 x 1024 pixel: 25 mm: 6GF9001-1BG01 ux) 1) 6GF3400-0SL03
(6GF3540-0GE10) 25 mm: 6GF3560-8EA03-0FF0 4)
or 35 mm: 6GF9001-1BH01 sh)

MV500 Ethernet Connection Cable MV550 50 mm: 6GF9001-1BJ01 ux) 1)


IP 65: IE switch SCALANCE XP208 length form 0.3 m to15 m available S; 800 x 600 pixel: 75 mm: 6GF9001-1BK01 shux) ²)
4)
Micro SD Card
(6GK5208-0HA00-2AS6) e.g. 2 m = 6XV1870-8GH20 (6GF3550-0CD10) shux) for Configuration
H; 1280 x 1024 pixel: shux) Backup; 4GB
(6GF3550-0GE10) 6GK6000-8HT01-0SA2
E-Focus lens
MV560 12 mm: 6GF3540-8EA01-0LL0 sh)
Support
S7-1200 via Industrial Ethernet or PROFINET U; 1920 x 1200 pixel:
(6GF3560-0LE10)
16 mm:
25 mm:
6GF3540-8EA02-0LL0 shu)
6GF3540-8EA03-0LL0 shux) Mounting plate
X; 2592 x 2048 pixel: 35 mm: 6GF3540-8EA04-0LL0 shux) 6GF3440-8CA
(6GF3560-0HE10) 50 mm: 6GF3540-8EA05-0LL0 shux) ²) Tri-plate

+ Direct connection (1 reader may be connected)


MV500 Ethernet Connection Cable
length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
+ Cable for
power supply
6GF9002-7AD

Opt. for Lens;


(no switch required)
Open wires Lights build-in Rings
red basic: 6GF3540-8DA11
10 m = 6GF3500-8BA21 0.5, 1, 5, 10, 20, 40 mm
Network Connection via Compact Switch Module red far: 6GF3540-8DA12
10 m UL = 6GF3500- 6GF9001-1BU
red multi: 6GF3540-8DA13
8BA23
white multi: 6GF3540-8DA33
S7-1200 CPU
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + A maximum of 3 readers may be connected)
MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ 30 m = 6GF3500-8BA41
30 m UL = 6GF3500-
8BA43
infrared basic: 6GF3540-8DA41
infrared far 6GF3540-8DA42
0.5, 1 mm
6GF9001-1BU01

CSM 1277 length doubler


e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) 6GF9001-1BV
(6GK7 277-1AA10-0AA0)
Use library “Ident Profile”
Poweror
supply Lights external: ring
EU connector Red: 6GF3400-0LT01-8DA1 Protective lens
6GT2 898-0AA00 Infrared: 6GF3400-0LT01-7BA1 cover
Basic length glas

S7-300/1500 via Direct connection (1 reader may be connected)


UK connector +
adapter M12/M12: 6GF3500-8BD10 no filter 6GF3540-8AC11

Industrial + MV500 Ethernet Connection Cable


length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
+ 6GT2 898-0AA10

US connector
6GT2 898-0AA20
mounting plate: 6GF3440-8CD01 red 6GF3540-8AC51
infrared 6GF3540-8AC41
IRUVcut 6GF3540-8AC31
(no switch required) Lights external: panel Long version glas ²)
Ethernet or cable for 24 V
5 m = 6GT2 891-0PH50
20x20 cm: 6GF3500-8DF30-1DA0
30x20 cm: 6GF3500-8DF30-2DA0
no filter 6GF3540-8AC12
S7-1500 CPU Network Connection via Compact Switch Module red 6GF3540-8AC52

PROFINET or
+
50 cm = 6GF3500-8BA11
40x30 cm: 6GF3500-8DF30-3DA0 infrared 6GF3540-8AC42
IRUVcut 6GF3540-8AC32
A maximum of 3 readers may be connected +
Mounting aid

+
S7-300 CPU
or
S7-300 with CP343-1
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ 5 m = 6GF3500-8BA12

1)
6GF3500-8CD

not in combination with build-in lights;


Basic length PMMA
6GF3540-8AC21

²) use long version of protective lens cover always and only Long version PMMA ²)
e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
Use library “Ident Profile” CSM 377 with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 6GF3540-8AC22
(6GK7 377-1AA00-0AA0) ³) Custom assembly necessary; use the correct stripping tool 4) No usage of option „Micro SD Card“ with these lens
shux) indicates the types of camera which are allowed for usage;

i.e. u) means MV5x0U is allowed

69 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
System Interfaces With power supply over Ethernet (PoE)
DO
Wires included in
Ethernet TCP/IP or PROFINET (PoE): 100MB power supply cable
„Open wires“

Software
Network Connection via SCALANCE Switches PoE Pat-Genius
6GF3400-0SL03
PC MV530
Use native TCP/IP with S; 800 x 600 pixel:
text based commands
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ (6GF3530-0CD10)
H; 1280 x 1024 pixel:
(6GF3530-0GE10) Micro SD Card
IE switch SCALANCE X108 PoE e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
(6GK5108-0PA00-2AA3) for Configuration
Backup; 4GB
or 6GK6000-8HT01-0SA2

S7-1200 CPU
Use library “Ident Profile”
MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ Cable for power
supply Support
e.g. 2 m = 6XV1870-8GH20
Open wires Mounting plate
IE switch SCALANCE XP208 PoE EEC 10 m = 6GF3500-8BA21 6GF3440-8CA
(6GK5208-0UA00-5ES6) 10 m UL = 6GF3500-8BA23 Tri-plate
30 m = 6GF3500-8BA41 6GF9002-7AD
or 30 m UL = 6GF3500-8BA43

S7-1500 CPU
or
MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ or
e.g. 2 m = 6XV1870-8GH20
S7-300 CPU Power supply
or IE switch SCALANCE XP216 PoE EEC
S7-300 with CP343-1 (6GK5216-0UA00-5ES6)
EU connector
Use library “Ident Profile” 6GT2 898-0AA00
or
UK connector
6GT2 898-0AA10

US connector
length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ 6GT2 898-0AA20

cable for 24 V
5 m = 6GT2 891-0PH50
IE switch SCALANCE XC208G PoE
(e.g. 6GK5208-0RA00-2AC2)
+
50 cm = 6GF3500-8BA11
or 5 m = 6GF3500-8BA12

IE switch SCALANCE XR326-2C PoE WG


length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+
(e.g. 6GK5326-2QS00-3AR3)
³) Custom assembly necessary; use the correct stripping tool

70 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
DO
System Interfaces With power supply over Ethernet (PoE)
Additional cable
for DO-supply is
Ethernet TCP/IP or PROFINET (PoE): 100MB needed
10 m = 6GF3500-8BA21
Manual focus lens 30 m = 6GF3500-8BA41
6 mm: 6GF9001-1BB01 s)

8.5 mm: 6GF9001-1BE01 sh) 1)


Software
12 mm: 6GF9001-1BL01 sh)
Veri-Genius
MV540 12 mm: 6GF3560-8EA01-0FF0 ux) 1)
6GF3400-0SL02
4)
S; 800 x 600 pixel: 16 mm: 6GF9001-1BF01
Network Connection via SCALANCE Switches PoE (6GF3540-0CD10) 16 mm: 6GF3560-8EA02-0FF0 sh) Pat-Genius
6GF3400-0SL03
PC H; 1280 x 1024 pixel: 25 mm: 6GF9001-1BG01 ux) 1)

(6GF3540-0GE10) 25 mm: 6GF3560-8EA03-0FF0 4)


Use native TCP/IP with
35 mm: 6GF9001-1BH01 sh) Micro SD Card
text based commands
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ MV550
S; 800 x 600 pixel:
(6GF3550-0CD10)
50 mm:
75 mm:
6GF9001-1BJ01
6GF9001-1BK01
ux) 1)
shux
4) ) ²)
shux)
for Configuration
Backup; 4GB
6GK6000-8HT01-0SA2
IE switch SCALANCE X108 PoE e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) H; 1280 x 1024 pixel: shux)

(6GK5108-0PA00-2AA3) (6GF3550-0GE10)
or Support
MV560
E-Focus lens
S7-1200 CPU
Use library “Ident Profile”
MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ U; 1920 x 1200 pixel:
(6GF3560-0LE10)
X; 2592 x 2048 pixel:
(6GF3560-0HE10)
12 mm:
16 mm:
25 mm:
6GF3540-8EA01-0LL0 sh)
6GF3540-8EA02-0LL0 shu)
6GF3540-8EA03-0LL0 shux)
Mounting plate
6GF3440-8CA
Tri-plate
6GF9002-7AD
e.g. 2 m = 6XV1870-8GH20 35 mm: 6GF3540-8EA04-0LL0 shux)
50 mm: 6GF3540-8EA05-0LL0 shux) ²)
IE switch SCALANCE XP208 PoE EEC Opt. for Lens;
(6GK5208-0UA00-5ES6)
Rings
or
0.5, 1, 5, 10, 20, 40 mm

S7-1500 CPU
or
MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ Lights build-in
6GF9001-1BU

0.5, 1 mm
6GF9001-1BU01
e.g. 2 m = 6XV1870-8GH20 red basic: 6GF3540-8DA11
S7-300 CPU
red far: 6GF3540-8DA12 length doubler
or IE switch SCALANCE XP216 PoE EEC red multi: 6GF3540-8DA13 6GF9001-1BV
S7-300 with CP343-1 (6GK5216-0UA00-5ES6) white multi: 6GF3540-8DA33
Use library “Ident Profile”
or infrared basic: 6GF3540-8DA41
infrared far 6GF3540-8DA42 Protective lens
cover
Basic length glas
length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ no filter 6GF3540-8AC11
red 6GF3540-8AC51
infrared 6GF3540-8AC41
IRUVcut 6GF3540-8AC31

IE switch SCALANCE XC208G PoE Long version glas ²)


(e.g. 6GK5208-0RA00-2AC2) no filter 6GF3540-8AC12
or red 6GF3540-8AC52
1)
infrared 6GF3540-8AC42
not in combination with build-in lights;
IRUVcut 6GF3540-8AC32

+
length from ²) use long version of protective lens cover always and only
0.5 to 50 m available with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0
Basic length PMMA
e.g. 2 m = 6XV1870-3QH20
4) No usage of option „Micro SD Card“ with these lens
shux) indicates the types of camera which are allowed for usage;
6GF3540-8AC21
IE switch SCALANCE XR326-2C PoE WG
(e.g. 6GK5326-2QS00-3AR3) i.e. u) means MV5x0U is allowed
Long version PMMA ²)
³) Custom assembly necessary; use the correct stripping tool 6GF3540-8AC22

71 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
System Interfaces With power supply over Ethernet (PoE) DO
Additional cable
Two parallel Networks on one Device: 1000MB + 100MB for DO-supply is
needed
1000MB / GigE Network, no PoE possible Manual focus lens
s)
10 m = 6GF3500-8BA21
6 mm: 6GF9001-1BB01 30 m = 6GF3500-8BA41
Direct connection
+ + Software
8.5 mm: 6GF9001-1BE01 sh) 1)

MV500 Ethernet Connection Cable 12 mm: 6GF9001-1BL01 sh)


Veri-Genius
length from 0.3 to 15 m available; e.g. 2 m = 6XV1878-5GH20 + 6GK1901-1BB12-2AA0 ³) MV550 12 mm: 6GF3560-8EA01-0FF0 ux) 1)
6GF3400-0SL02
4)
(no switch required) S; 800 x 600 pixel: 16 mm: 6GF9001-1BF01
Pat-Genius
(6GF3550-0CD10) 16 mm: 6GF3560-8EA02-0FF0 sh)
ux) 1) 6GF3400-0SL03
H; 1280 x 1024 pixel: 25 mm: 6GF9001-1BG01
PC Network Connection via Switch (6GF3550-0GE10) 25 mm: 6GF3560-8EA03-0FF0 4)
Use native TCP/IP with
text based commands + length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + MV500 Ethernet Connection Cable + MV560
U; 1920 x 1200 pixel:
35 mm:
50 mm:
75 mm:
6GF9001-1BH01
6GF9001-1BJ01
6GF9001-1BK01
sh)
ux) 1)
shux
4) ) ²)
Micro SD Card
for Configuration
Backup; 4GB
length from 0.3 to 15 m available (6GF3560-0LE10) shux)

e.g. 2 m = 6XV1878-5GH20 + 6GK1901-1BB12-2AA0 ³) 6GK6000-8HT01-0SA2


X; 2592 x 2048 pixel: shux)
IP 20: IE switch SCALANCE X GB (e.g. 6GK5208-0GA00-2AC2) (6GF3560-0HE10)
Support
E-Focus lens
+ MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ 12 mm:
16 mm:
25 mm:
6GF3540-8EA01-0LL0 sh)
6GF3540-8EA02-0LL0 shu)
6GF3540-8EA03-0LL0 shux)
Mounting plate
6GF3440-8CA
Tri-plate
6GF9002-7AD
e.g. 2 m = 6XV1878-5GH20
IP 65: IE switch SCALANCE XP216 (e.g. 6GK5216-0HA00-2AS6) 35 mm: 6GF3540-8EA04-0LL0 shux)
50 mm: 6GF3540-8EA05-0LL0 shux) ²)
Opt. for Lens;
Rings
100 MB / Profinet Network, Switch with PoE 0.5, 1, 5, 10, 20, 40 mm
Network Connection via SCALANCE Switches PoE 6GF9001-1BU

0.5, 1 mm
Lights build-in 6GF9001-1BU01
red basic: 6GF3540-8DA11

PC
Use native TCP/IP with
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ red far:
red multi:
white multi:
6GF3540-8DA12
6GF3540-8DA13
6GF3540-8DA33
length doubler
6GF9001-1BV

text based commands IE switch SCALANCE X108 PoE e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) infrared basic: 6GF3540-8DA41
(6GK5108-0PA00-2AA3) infrared far 6GF3540-8DA42 Protective lens
or cover
IE switch SCALANCE X308-2M PoE Basic length glas
(6GK5308-2QG00-2AA2) no filter 6GF3540-8AC11
or red 6GF3540-8AC51
S7-1200 CPU IE switch SCALANCE XR324-4M PoE infrared 6GF3540-8AC41
Use library “Ident Profile” (e.g. 6GK5324-4QG00-3AR2) IRUVcut 6GF3540-8AC31
or
Long version glas ²)

MV500 Ethernet Connection Cable


length from 0.3 to 15 m available
+ 1)
no filter 6GF3540-8AC12
red 6GF3540-8AC52
infrared 6GF3540-8AC42
S7-1500 CPU e.g. 2 m = 6XV1870-8GH20 not in combination with build-in lights; IRUVcut 6GF3540-8AC32
or ²) use long version of protective lens cover always and only
IE switch SCALANCE XP208 PoE EEC with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 Basic length PMMA
S7-300 CPU 4) No usage of option „Micro SD Card“ with these lens
(6GK5208-0UA00-5ES6) 6GF3540-8AC21
or shux) indicates the types of camera which are allowed for usage;

S7-300 with CP343-1 or i.e. u) means MV5x0U is allowed


IE switch SCALANCE XP216 PoE EEC Long version PMMA ²)
Use library “Ident Profile” (6GK5216-0UA00-5ES6) 6GF3540-8AC22

72 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
A maximum of 1 reader may be connected
System Interfaces + + With power supply over Ethernet (PoE)
DO
+ Wires included in
SIMATIC PLC power supply cable
„Open wires“
S7-1200 RF120C
6GT2 002-0LA00

Software
Pat-Genius
6GF3400-0SL03
MV530
SIMATIC PLC A maximum of 2 readers may be connected S; 800 x 600 pixel:

S7-300 Rack or + + + (6GF3530-0CD10)


H; 1280 x 1024 pixel:
(6GF3530-0GE10) Micro SD Card
S7-400 via ET 200M + for Configuration
Backup; 4GB
(DP-V1/PN-IO) ASM 475 + Front connector
(6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0)
6GK6000-8HT01-0SA2

Cable for power


Accessories:
Connecting element (6ES7 390-5AA00-0AA0) supply Support
Terminal element (6ES7 390-5BA00-0AA0)
Open wires Mounting plate
10 m = 6GF3500-8BA21 6GF3440-8CA
10 m UL = 6GF3500-8BA23 Tri-plate
30 m = 6GF3500-8BA41 6GF9002-7AD
ET 200pro PROFIBUS DP-V1 30 m UL = 6GF3500-8BA43
ET 200pro Interface module
A maximum of 2 readers may be connected or
via PROFIBUS ET 200pro PROFINET
Interface module + + + Power supply
or PROFINET adapting cable: And extension cables:
50 cm = 6GF3500-8BA11
5 m = 6GF3500-8BA12 (+) 2 m = 6GT2 891-4FH20 EU connector
or S7 PLC ET 200pro PROFINET
CPU module
RF170C
Communication module
5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10
6GT2 898-0AA00

20 m = 6GT2 891-4FN20 UK connector


Up to 9 x 170C (6GT2002-0HD01) 50 m = 6GT2 891-4FN50 6GT2 898-0AA10
Connection block
modules per (6GT2002-1HD01)
ET 200pro rack US connector
6GT2 898-0AA20

cable for 24 V
A maximum of 2 readers may be connected 5 m = 6GT2 891-0PH50
PROFIBUS + RF166C to MV500
adapting cable:
+
And extension cables:
+
50 cm = 6GF3500-8BA11
5 m = 6GF3500-8BA12
50 cm = 6GF3500-8BA11
5 m = 6GF3500-8BA12
(+) 2 m = 6GT2 891-4FH20
5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10
20 m = 6GT2 891-4FN20
RF166C (DP-V1) 50 m = 6GT2 891-4FN50
Communication Module
(6GT2 002-0EE20)

73 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
A maximum of 1 reader may be connected
System Interfaces + + With power supply over Ethernet (PoE)
Software
+ Veri-Genius
SIMATIC PLC 6GF3400-0SL02
Pat-Genius
Manual focus lens 6GF3400-0SL03
S7-1200 RF120C 6 mm: 6GF9001-1BB01 s)

8.5 mm: 6GF9001-1BE01 sh) 1)


6GT2 002-0LA00 12 mm: 6GF9001-1BL01 sh)

MV540 12 mm: 6GF3560-8EA01-0FF0 ux) 1) Micro SD Card


4)
S; 800 x 600 pixel: 16 mm: 6GF9001-1BF01 for Configuration
(6GF3540-0CD10) 16 mm: 6GF3560-8EA02-0FF0 sh) Backup; 4GB
ux) 1)
H; 1280 x 1024 pixel: 25 mm: 6GF9001-1BG01 6GK6000-8HT01-0SA2
SIMATIC PLC A maximum of 2 readers may be connected (6GF3540-0GE10) 25 mm: 6GF3560-8EA03-0FF0 4)

+ + +
sh)
35 mm: 6GF9001-1BH01
MV550 50 mm: 6GF9001-1BJ01 ux) 1)

S7-300 Rack or S; 800 x 600 pixel:


(6GF3550-0CD10)
75 mm: 6GF9001-1BK01 shux
4) ) ²)
shux)
Support

S7-400 via ET 200M + H; 1280 x 1024 pixel:


(6GF3550-0GE10)
shux) Mounting plate
6GF3440-8CA
Tri-plate
(DP-V1/PN-IO) ASM 475 + Front connector
(6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0)
MV560
U; 1920 x 1200 pixel: E-Focus lens
6GF9002-7AD

(6GF3560-0LE10) 12 mm: 6GF3540-8EA01-0LL0 sh)


Accessories: X; 2592 x 2048 pixel: 16 mm: 6GF3540-8EA02-0LL0 shu) Opt. for Lens;
Connecting element (6ES7 390-5AA00-0AA0) (6GF3560-0HE10) 25 mm: 6GF3540-8EA03-0LL0 shux) Rings
Terminal element (6ES7 390-5BA00-0AA0) 35 mm: 6GF3540-8EA04-0LL0 shux)
50 mm: 6GF3540-8EA05-0LL0 shux) ²) 0.5, 1, 5, 10, 20, 40 mm
6GF9001-1BU

0.5, 1 mm
ET 200pro PROFIBUS DP-V1 6GF9001-1BU01
ET 200pro Interface module
A maximum of 2 readers may be connected length doubler

via PROFIBUS ET 200pro PROFINET


Interface module + + + Lights build-in
red basic: 6GF3540-8DA11
6GF9001-1BV

or PROFINET adapting cable: And extension cables: red far: 6GF3540-8DA12


50 cm = 6GF3500-8BA11
5 m = 6GF3500-8BA12 (+) 2 m = 6GT2 891-4FH20 red multi: 6GF3540-8DA13

or S7 PLC ET 200pro PROFINET


CPU module
RF170C
Communication module
5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10
white multi: 6GF3540-8DA33
infrared basic: 6GF3540-8DA41 Protective lens
20 m = 6GT2 891-4FN20 infrared far 6GF3540-8DA42 cover
Up to 9 x 170C (6GT2002-0HD01) 50 m = 6GT2 891-4FN50 Basic length glas
Connection block
modules per no filter 6GF3540-8AC11
(6GT2002-1HD01)
ET 200pro rack red 6GF3540-8AC51
infrared 6GF3540-8AC41
IRUVcut 6GF3540-8AC31

A maximum of 2 readers may be connected Long version glas ²)


PROFIBUS + RF166C to MV500
adapting cable:
+
And extension cables:
no filter 6GF3540-8AC12
red 6GF3540-8AC52
infrared 6GF3540-8AC42
50 cm = 6GF3500-8BA11
5 m = 6GF3500-8BA12
(+) 2 m = 6GT2 891-4FH20
5 m = 6GT2 891-4FH50
1) not in combination with build-in lights;
IRUVcut 6GF3540-8AC32

²) use long version of protective lens cover always and only Basic length PMMA
10 m = 6GT2 891-4FN10 with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 6GF3540-8AC21
20 m = 6GT2 891-4FN20 4) No usage of option „Micro SD Card“ with these lens
RF166C (DP-V1) 50 m = 6GT2 891-4FN50 shux) indicates the types of camera which are allowed for usage;
Long version PMMA ²)
Communication Module i.e. u) means MV5x0U is allowed 6GF3540-8AC22
(6GT2 002-0EE20)

74 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
System Interfaces With power supply over Ethernet (PoE)
DO
Wires included in
PROFINET & Ethernet/IP & OPC UA & TCP/IP power supply cable
„Open wires“

Communication Modules Software


A maximum of Pat-Genius
1 reader at RF185C, 6GF3400-0SL03
MV530
2 readers at RF186C/CI, S; 800 x 600 pixel:
4 readers at RF188C/CI (6GF3530-0CD10)
of MV500 may be connected H; 1280 x 1024 pixel:
(6GF3530-0GE10) Micro SD Card
RF185C
(6GT2 002-0JE10)
RF186C
(6GT2 002-0JE20)
RF188C
(6GT2 002-0JE40) + adapting cable:
50 cm = 6GF3500-8BA11 (+) And extension cables:
2 m = 6GT2 891-4FH20
+ for Configuration
Backup; 4GB
6GK6000-8HT01-0SA2
5 m = 6GF3500-8BA12 5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10 Cable for power
Additional IOs 20 m = 6GT2 891-4FN20
supply
50 m = 6GT2 891-4FN50 Support
Open wires Mounting plate
10 m = 6GF3500-8BA21 6GF3440-8CA
10 m UL = 6GF3500-8BA23 Tri-plate
30 m = 6GF3500-8BA41 6GF9002-7AD
30 m UL = 6GF3500-8BA43
Types of IO-Link

RF186CI RF188CI
+ RF18xCI to sensor
+ I/O module
IO-extension module
or
(6GT2 002-0JE50) (6GT2 002-0JE60) 6ES7 14….. (up to 8xDI + 8xDO)
Sensor cable from Power supply
0.5 to 15 m available See page 88 for detailed information EU connector
(e.g. 2 m = 6XV1801-2CH20)
6GT2 898-0AA00

UK connector
6GT2 898-0AA10

Or one US connector
6GT2 898-0AA20
Standard sensor
cable for 24 V
5 m = 6GT2 891-0PH50
Or one +
50 cm = 6GF3500-8BA11
Actor 5 m = 6GF3500-8BA12

75 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
System Interfaces Powered through connection cable
Software
Veri-Genius
PROFINET & Ethernet/IP & OPC UA & TCP/IP 6GF3400-0SL02
Pat-Genius
Manual focus lens 6GF3400-0SL03
6 mm: 6GF9001-1BB01 s)

8.5 mm: 6GF9001-1BE01 sh) 1)

12 mm: 6GF9001-1BL01 sh)


Micro SD Card
Communication Modules MV540 12 mm: 6GF3560-8EA01-0FF0 ux) 1)
S; 800 x 600 pixel: 16 mm: 6GF9001-1BF01 4) for Configuration
A maximum of Backup; 4GB
(6GF3540-0CD10) 16 mm: 6GF3560-8EA02-0FF0 sh)
1 reader at RF185C, H; 1280 x 1024 pixel: 25 mm: 6GF9001-1BG01 ux) 1) 6GK6000-8HT01-0SA2
2 readers at RF186C/CI, (6GF3540-0GE10) 25 mm: 6GF3560-8EA03-0FF0 4)
sh)
4 readers at RF188C/CI 35 mm: 6GF9001-1BH01
MV550 50 mm: 6GF9001-1BJ01 ux) 1)
of MV500 may be connected S; 800 x 600 pixel: 75 mm: 6GF9001-1BK01 shux
4) ) ²) Support
(6GF3550-0CD10) shux)
Mounting plate
RF185C
(6GT2 002-0JE10)
RF186C
(6GT2 002-0JE20)
RF188C
(6GT2 002-0JE40) + adapting cable:
50 cm = 6GF3500-8BA11 (+) And extension cables:
2 m = 6GT2 891-4FH20
+ H; 1280 x 1024 pixel:
(6GF3550-0GE10)

MV560
shux)
6GF3440-8CA
Tri-plate
6GF9002-7AD
5 m = 6GF3500-8BA12 5 m = 6GT2 891-4FH50 U; 1920 x 1200 pixel: E-Focus lens
10 m = 6GT2 891-4FN10 (6GF3560-0LE10) 12 mm: 6GF3540-8EA01-0LL0 sh)
Opt. for Lens;
Additional IOs 20 m = 6GT2 891-4FN20
50 m = 6GT2 891-4FN50
X; 2592 x 2048 pixel: 16 mm:
25 mm:
6GF3540-8EA02-0LL0 shu)
6GF3540-8EA03-0LL0 shux) Rings
(6GF3560-0HE10)
35 mm: 6GF3540-8EA04-0LL0 shux) 0.5, 1, 5, 10, 20, 40 mm
50 mm: 6GF3540-8EA05-0LL0 shux) ²)
6GF9001-1BU

0.5, 1 mm
6GF9001-1BU01
Types of IO-Link

RF186CI RF188CI
+ RF18xCI to sensor
+ I/O module
IO-extension module
Lights build-in
length doubler
6GF9001-1BV
red basic: 6GF3540-8DA11
(6GT2 002-0JE50) (6GT2 002-0JE60) 6ES7 14….. (up to 8xDI + 8xDO) red far: 6GF3540-8DA12
Sensor cable from
0.5 to 15 m available red multi: 6GF3540-8DA13
See page 88 for detailed information white multi: 6GF3540-8DA33
(e.g. 2 m = 6XV1801-2CH20)
infrared basic: 6GF3540-8DA41 Protective lens
infrared far 6GF3540-8DA42 cover
Basic length glas
no filter 6GF3540-8AC11
red 6GF3540-8AC51
Or one 1) not in combination with infrared 6GF3540-8AC41
Standard sensor build-in lights; IRUVcut 6GF3540-8AC31
²) use long version of Lights external
protective lens cover always Red: 6GF3400-0LT01-8DA1 Long version glas ²)
and only Infrared: 6GF3400-0LT01-7BA1 no filter 6GF3540-8AC12
Or one with 6GF9001-1BK01
and 6GF3540-8EA05-0LL0
+
adapter M12/M12
red 6GF3540-8AC52
infrared 6GF3540-8AC42
Actor 4) No usage of option „Micro (6GF3500-8BD10) IRUVcut 6GF3540-8AC32
SD Card“ with these lens
shux) indicates the types of
+
Mounting plate Basic length PMMA
camera which are allowed for (6GF3440-8CD01) 6GF3540-8AC21
usage;
i.e. u) means MV5x0U is Long version PMMA ²)
allowed 6GF3540-8AC22

76 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
System Interfaces With external power supply
DO
Wires included in
Serial RS232 power supply cable
„Open wires“

RS232
RS232
1 Reader per COM port may be connected Software
Terminal
box /
switching
DI/DO
RS 232 cable for MV500 (open wires)
+ MV530
S; 800 x 600 pixel:
Pat-Genius
6GF3400-0SL03

cabinet
10 m = 6GF3500-8BA21 (6GF3530-0CD10)
24VDC OUT H; 1280 x 1024 pixel:
30 m = 6GF3500-8BA41
(6GF3530-0GE10) Micro SD Card
for Configuration
Backup; 4GB
24VDC IN DI/DO (opt.) 6GK6000-8HT01-0SA2
Simple text based
protocol Cable for power
supply Support
Open wires Mounting plate
10 m = 6GF3500-8BA21 6GF3440-8CA
10 m UL = 6GF3500-8BA23 Tri-plate
30 m = 6GF3500-8BA41 6GF9002-7AD
30 m UL = 6GF3500-8BA43

or
Power supply
EU connector
6GT2 898-0AA00

UK connector
6GT2 898-0AA10

US connector
6GT2 898-0AA20

cable for 24 V
5 m = 6GT2 891-0PH50
+
50 cm = 6GF3500-8BA11
5 m = 6GF3500-8BA12

77 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
System Interfaces With external power supply
DO
Wires included in
Serial RS232 Manual focus lens power supply cable
6 mm: 6GF9001-1BB01 s)
„Open wires“
8.5 mm: 6GF9001-1BE01 sh) 1)

12 mm: 6GF9001-1BL01 sh)


Software
12 mm: 6GF3560-8EA01-0FF0 ux) 1)
RS232 16 mm: 6GF9001-1BF01 4) Veri-Genius
RS232 MV540 6GF3400-0SL02
1 Reader per COM port may be connected 16 mm: 6GF3560-8EA02-0FF0 sh)
Pat-Genius

+
S; 800 x 600 pixel: 25 mm: 6GF9001-1BG01 ux) 1)
Terminal
(6GF3540-0CD10) 25 mm: 6GF3560-8EA03-0FF0 4) 6GF3400-0SL03
box / DI/DO sh)
H; 1280 x 1024 pixel: 35 mm: 6GF9001-1BH01
switching
RS 232 cable for MV500 (open wires) (6GF3540-0GE10) 50 mm: 6GF9001-1BJ01 ux) 1)
cabinet 75 mm: 6GF9001-1BK01 shux) ²)
4)
24VDC OUT 10 m = 6GF3500-8BA21 MV550 shux)
Micro SD Card
30 m = 6GF3500-8BA41 S; 800 x 600 pixel: shux)
for Configuration
(6GF3550-0CD10) Backup; 4GB
H; 1280 x 1024 pixel: E-Focus lens 6GK6000-8HT01-0SA2
(6GF3550-0GE10) 12 mm: 6GF3540-8EA01-0LL0 sh)
16 mm: 6GF3540-8EA02-0LL0 shu)
24VDC IN DI/DO (opt.) MV560 25 mm: 6GF3540-8EA03-0LL0 shux) Support
Simple text based U; 1920 x 1200 pixel: 35 mm: 6GF3540-8EA04-0LL0 shux)
protocol (6GF3560-0LE10) 50 mm: 6GF3540-8EA05-0LL0 shux) ²)
Mounting plate
X; 2592 x 2048 pixel: 6GF3440-8CA
(6GF3560-0HE10) Tri-plate
6GF9002-7AD

Lights build-in Opt. for Lens;


red basic: 6GF3540-8DA11
red far: 6GF3540-8DA12
Rings
red multi: 6GF3540-8DA13 0.5, 1, 5, 10, 20, 40 mm
white multi: 6GF3540-8DA33 6GF9001-1BU
infrared basic: 6GF3540-8DA41
infrared far 6GF3540-8DA42 0.5, 1 mm
6GF9001-1BU01

length doubler
6GF9001-1BV
Lights external: ring
1) not in combination Red: 6GF3400-0LT01-8DA1 Protective lens
with build-in lights; Infrared: 6GF3400-0LT01-7BA1 cover
²) use long version of +
adapter M12/M12: 6GF3500-8BD10
Basic length glas
protective lens cover no filter 6GF3540-8AC11
always and only mounting plate: 6GF3440-8CD01 red 6GF3540-8AC51
with 6GF9001- infrared 6GF3540-8AC41
1BK01 and 6GF3540- IRUVcut 6GF3540-8AC31
8EA05-0LL0
4) No usage of option Lights external: panel Long version glas ²)
„Micro SD Card“ with 20x20 cm: 6GF3500-8DF30-1DA0 no filter 6GF3540-8AC12
these lens 30x20 cm: 6GF3500-8DF30-2DA0 red 6GF3540-8AC52
shux) indicates the types infrared 6GF3540-8AC42
40x30 cm: 6GF3500-8DF30-3DA0
of camera which are
allowed for usage;
+
Mounting aid
IRUVcut 6GF3540-8AC32

i.e. u) means 6GF3500-8CD Basic length PMMA


MV5x0U is allowed 6GF3540-8AC21

Long version PMMA ²)


6GF3540-8AC22

78 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
System Interfaces Direct connection With external power supply DO
+ MV500 Ethernet Connection Cable
length from 2 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
+ Wires included in
power supply cable
Ethernet TCP/IP (no switch required)
6 mm:
Manual focus lens
6GF9001-1BB01 s)
„Open wires“
Network Connection via Switch 8.5 mm: 6GF9001-1BE01 sh) 1)
Software
12 mm: 6GF9001-1BL01 sh)

Use native TCP/IP


with text based
+ + + MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ MV540
12 mm:
16 mm:
16 mm:
6GF3560-8EA01-0FF0 ux) 1)
6GF9001-1BF01 4)

6GF3560-8EA02-0FF0 shu)
Veri-Genius
6GF3400-0SL02
Pat-Genius
commands IP 20: IE switch SCALANCE X (6GK5 …) e.g. 2 m 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
S; 800 x 600 pixel:
(6GF3540-0CD10)
25 mm:
25 mm:
6GF9001-1BG01 ux) 1)

6GF3560-8EA03-0FF0 4)
6GF3400-0SL03

or H; 1280 x 1024 pixel: 35 mm: 6GF9001-1BH01 sh)

(6GF3540-0GE10) 50 mm: 6GF9001-1BJ01 ux) 1)


MV500 Ethernet Connection Cable Micro SD Card
IP 65: IE switch SCALANCE XP208 length form 0.3 m to15 m available MV550
75 mm: 6GF9001-1BK01 shux) ²)
4)
shux)
(6GK5208-0HA00-2AS6) e.g. 2 m = 6XV1870-8GH20 for Configuration
S; 800 x 600 pixel: shux)
Backup; 4GB
(6GF3550-0CD10)
6GK6000-8HT01-0SA2
H; 1280 x 1024 pixel: E-Focus lens
(6GF3550-0GE10) 12 mm: 6GF3540-8EA01-0LL0 sh)
16 mm: 6GF3540-8EA02-0LL0 shu) Support
S7-1200 via Industrial Ethernet or PROFINET MV560
U; 1920 x 1200 pixel:
25 mm:
35 mm:
6GF3540-8EA03-0LL0 shux)
6GF3540-8EA04-0LL0 shux)
Mounting plate
6GF3440-8CA
(6GF3560-0LE10)
50 mm: 6GF3540-8EA05-0LL0 shux) ²)

+ Direct connection (1 reader may be connected)


+ X; 2592 x 2048 pixel: Tri-plate
(6GF3560-0HE10) 6GF9002-7AD
MV500 Ethernet Connection Cable
length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
(no switch required)
Cable for Opt. for Lens;
power supply Lights build-in Rings
red basic: 6GF3540-8DA11
Network Connection via Compact Switch Module Open wires red far: 6GF3540-8DA12 0.5, 1, 5, 10, 20, 40 mm
10 m = 6GF3500-8BA21 red multi: 6GF3540-8DA13 6GF9001-1BU

S7-1200 CPU
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + A maximum of 3 readers may be connected)
MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ 10 m UL = 6GF3500-
8BA23
30 m = 6GF3500-8BA41
30 m UL = 6GF3500-
white multi: 6GF3540-8DA33
infrared basic: 6GF3540-8DA41
infrared far 6GF3540-8DA42
0.5, 1 mm
6GF9001-1BU01

CSM 1277 8BA43 length doubler


e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) 6GF9001-1BV
(6GK7 277-1AA10-0AA0)
Use library “Ident Profile”
or
Lights external: ring Protective lens
Power supply Red: 6GF3400-0LT01-8DA1
EU connector Infrared: 6GF3400-0LT01-7BA1 cover
Basic length glas
S7-300/1500 via Industrial Ethernet or PROFINET 6GT2 898-0AA00 +
adapter M12/M12: 6GF3500-8BD10 no filter 6GF3540-8AC11
UK connector mounting plate: 6GF3440-8CD01 red 6GF3540-8AC51
Direct connection (1 reader may be connected) 6GT2 898-0AA10 infrared 6GF3540-8AC41

+ MV500 Ethernet Connection Cable


length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
+ US connector
6GT2 898-0AA20
Lights external: panel
IRUVcut 6GF3540-8AC31

Long version glas ²)


(no switch required) no filter 6GF3540-8AC12
cable for 24 V 20x20 cm: 6GF3500-8DF30-1DA0 red 6GF3540-8AC52
Network Connection via Compact Switch Module 5 m = 6GT2 891-0PH50 30x20 cm: 6GF3500-8DF30-2DA0 infrared 6GF3540-8AC42
S7-1500 CPU 40x30 cm: 6GF3500-8DF30-3DA0
+ IRUVcut 6GF3540-8AC32
or
A maximum of 3 readers may be connected 50 cm = 6GF3500-8BA11 +
S7-300 CPU
or
S7-300 with CP343-1
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ 5 m = 6GF3500-8BA12

1)
Mounting aid
6GF3500-8CD
not in combination with build-in lights;
Basic length PMMA
6GF3540-8AC21

Long version PMMA ²)


²) use long version of protective lens cover always and only
Use library “Ident Profile” CSM 377 e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 6GF3540-8AC22
(6GK7 377-1AA00-0AA0) ³) Custom assembly necessary; use the correct stripping tool 4) No usage of option „Micro SD Card“ with these lens
shux) indicates the types of camera which are allowed for usage;

i.e. u) means MV5x0U is allowed


79 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
System Interfaces With external power supply
DO
Wires included in
Ethernet Network Connection via SCALANCE Switches PoE power supply cable
„Open wires“
PC
TCP/IP or Use native TCP/IP with

PROFINET text based commands


+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + MV500 Ethernet Connection Cable
+ Software
Pat-Genius
(PoE): IE switch SCALANCE X108 PoE
length from 0.3 to 15 m available
e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) MV530
6GF3400-0SL03
(6GK5108-0PA00-2AA3)
100MB or
S; 800 x 600 pixel:
(6GF3530-0CD10)
H; 1280 x 1024 pixel:

S7-1200 CPU
MV500 Ethernet Connection + (6GF3530-0GE10) Micro SD Card
for Configuration
Use library “Ident Profile” Cable Backup; 4GB
length from 0.3 to 15 m available 6GK6000-8HT01-0SA2
e.g. 2 m = 6XV1870-8GH20
IE switch SCALANCE XP208 PoE EEC Cable for power
(6GK5208-0UA00-5ES6) supply Support
or Open wires Mounting plate

+
10 m = 6GF3500-8BA21 6GF3440-8CA
10 m UL = 6GF3500-8BA23 Tri-plate
S7-1500 CPU MV500 Ethernet Connection 30 m = 6GF3500-8BA41 6GF9002-7AD
30 m UL = 6GF3500-8BA43
or Cable
S7-300 CPU length from 0.3 to 15 m available
or e.g. 2 m = 6XV1870-8GH20
or
S7-300 with CP343-1 IE switch SCALANCE XP216 PoE EEC
(6GK5216-0UA00-5ES6)
Use library “Ident Profile”
Power supply
or EU connector
6GT2 898-0AA00

UK connector
6GT2 898-0AA10
length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ US connector
6GT2 898-0AA20

cable for 24 V
IE switch SCALANCE XC208G PoE 5 m = 6GT2 891-0PH50
(e.g. 6GK5208-0RA00-2AC2) +
50 cm = 6GF3500-8BA11
or 5 m = 6GF3500-8BA12

length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+
IE switch SCALANCE XR326-2C PoE WG
(e.g. 6GK5326-2QS00-3AR3) ³) Custom assembly necessary; use the correct stripping tool

80 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV500 Reader Options
System Interfaces With power supply over Ethernet (PoE) DO
Additional cable
for DO-supply is
Two parallel Networks on one Device: 1000MB + 100MB needed
10 m = 6GF3500-8BA21
Manual focus lens 30 m = 6GF3500-8BA41
1000MB / GigE Network, no PoE needed 6 mm: 6GF9001-1BB01 s)

Direct connection 8.5 mm: 6GF9001-1BE01 sh) 1) Software

+ + 12 mm: 6GF9001-1BL01 sh)


Veri-Genius
MV500 Ethernet Connection Cable MV550 12 mm: 6GF3560-8EA01-0FF0 ux) 1)
6GF3400-0SL02
4)
length from 0.3 to 15 m available; e.g. 2 m = 6XV1878-5GH20 + 6GK1901-1BB12-2AA0 ³) S; 800 x 600 pixel: 16 mm: 6GF9001-1BF01
Pat-Genius
(no switch required) (6GF3550-0CD10) 16 mm: 6GF3560-8EA02-0FF0 shu)
ux) 1) 6GF3400-0SL03
H; 1280 x 1024 pixel: 25 mm: 6GF9001-1BG01
(6GF3550-0GE10) 25 mm: 6GF3560-8EA03-0FF0 4)
PC Network Connection via Switch 35 mm: 6GF9001-1BH01 sh) Micro SD Card
Use native TCP/IP with
text based commands + length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + MV500 Ethernet Connection Cable +
MV560
U; 1920 x 1200 pixel:
(6GF3560-0LE10)
50 mm:
75 mm:
6GF9001-1BJ01
6GF9001-1BK01
ux) 1)
shux
4) ) ²)
shux)
for Configuration
Backup; 4GB
6GK6000-8HT01-0SA2
length from 0.3 to 15 m available X; 2592 x 2048 pixel: shux)
e.g. 2 m = 6XV1878-5GH20 + 6GK1901-1BB12-2AA0 ³) (6GF3560-0HE10)
IP 20: IE switch SCALANCE X GB (e.g. 6GK5208-0GA00-2AC2) Support
E-Focus lens Mounting plate

+ MV500 Ethernet Connection Cable


length from 0.3 to 15 m available
+ 12 mm:
16 mm:
25 mm:
6GF3540-8EA01-0LL0 sh)
6GF3540-8EA02-0LL0 shu)
6GF3540-8EA03-0LL0 shux)
6GF3440-8CA
Tri-plate
6GF9002-7AD
e.g. 2 m = 6XV1878-5GH20 35 mm: 6GF3540-8EA04-0LL0 shux)
IP 65: IE switch SCALANCE XP216 (e.g. 6GK5216-0HA00-2AS6) 50 mm: 6GF3540-8EA05-0LL0 shux) ²)
Opt. for Lens;
Rings
0.5, 1, 5, 10, 20, 40 mm
100 MB / Profinet Network, Switch with PoE 6GF9001-1BU
Network Connection via SCALANCE Switches PoE
0.5, 1 mm
Lights build-in 6GF9001-1BU01
red basic: 6GF3540-8DA11

PC
Use native TCP/IP with
text based commands
+ length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ red far:
red multi:
white multi:
6GF3540-8DA12
6GF3540-8DA13
6GF3540-8DA33
infrared basic: 6GF3540-8DA41
length doubler
6GF9001-1BV

IE switch SCALANCE X108 PoE e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) Protective lens


(6GK5108-0PA00-2AA3) infrared far 6GF3540-8DA42
cover
or Basic length glas
IE switch SCALANCE X308-2M PoE no filter 6GF3540-8AC11
(6GK5308-2QG00-2AA2) red 6GF3540-8AC51
S7-1200 CPU or
infrared 6GF3540-8AC41
IE switch SCALANCE XR324-4M PoE
Use library “Ident Profile” (e.g. 6GK5324-4QG00-3AR2)
IRUVcut 6GF3540-8AC31
or Long version glas ²)

S7-1500 CPU
MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ 1) not in combination with build-in lights;
no filter 6GF3540-8AC12
red 6GF3540-8AC52
infrared 6GF3540-8AC42
IRUVcut 6GF3540-8AC32
e.g. 2 m = 6XV1870-8GH20 ²) use long version of protective lens cover always and only
or with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 Basic length PMMA
S7-300 CPU IE switch SCALANCE XP208 PoE EEC 4) No usage of option „Micro SD Card“ with these lens 6GF3540-8AC21
or (6GK5208-0UA00-5ES6) shux) indicates the types of camera which are allowed for usage;

S7-300 with CP343-1 or i.e. u) means MV5x0U is allowed Long version PMMA ²)
IE switch SCALANCE XP216 PoE EEC
Use library “Ident Profile” (6GK5216-0UA00-5ES6)
6GF3540-8AC22
³) Custom assembly necessary; use the correct stripping tool

81 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV300
System Interfaces

82 Unrestricted | © Siemens 2023 | All rights reserved.


MV320, MV326 Reader Options
System Interfaces Powered through USB-cable

MV320
PC via USB (6GF3320-
0HT01)
1 Reader per USB port may be connected
PC
USB cable for MV320/ MV326
The USB-cable (1.8 m) is included in the delivery scope
MV326 with
Docking station
(6GF3326-0HT01)

Panel PC Spare Battery


for MV326
(6GF3326-0AC07 *)

RF170C Reader
Powered through connection cable
ET200pro ET200pro PROFIBUS DP-V1
Interface module
via PROFIBUS
A maximum of 2 readers may be connected
or PROFINET
or S7 PLC
ET200pro PROFINET
Interface module + RS 232 cable for MV320
1.6 to 4 m = 6GT2191-0BH50
ET200pro PROFINET RF170C
CPU module Communication module
(6GT2 002-0HD01)
Up to 9 x 170C Connection block
modules per (6GT2 002-1HD01)
ET200pro rack

MV320
(6GF3320-0HT01)

SIMATIC PLC Metal stand for


MV320
S7-1200 A maximum of 1 readers may be connected (6GF3320-0AC07)

+ RF120C to MV320
1.6 to 4 m = 6GT2191-1BH50
+
RF120C
6GT2 002-0LA00
Up to 3 x RF120C modules
per S7-1200 rack * planned

83 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


MV320, MV326 Reader Options
System Interfaces Powered through connection cable

PROFINET & Ethernet/IP


Communication Modules
A maximum of
1 reader at RF185C,
2 readers at RF186C/CI, RF188C/CI

RF185C RF186C RF188C


+ of MV300 may be connected
RS 232 cable for MV320
1.6 to 4 m = 6GT2191-0BH50
+
(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40)

Additional IOs MV320


+ RF18xCI to sensor + Types of IO-Link
IO module
IO-extension module
(6GF3320-0HT01)

Sensor cable from 6ES7 14….. (up to 8xDI + 8xDO)


0.5 to 15 m available
(e.g. 2 m = 6XV1801-2CH20) See page 88 for detailed information
Or one Standard sensor
RF186CI RF188CI
(6GT2 002-0JE50) (6GT2 002-0JE60) Or oneActor

PROFIBUS
A maximum of 2 readers may be connected
+ RS 232 cable for MV320
+ Metal stand for
1.6 to 4 m = 6GT2191-0BH50
RF166C (DP-V1) MV320
Communication Module (6GF3320-0AC07)
(6GT2 002-0EE20)

RS232 1 Reader per RS232 port may be connected


Reader
With external power supply
For SIMATIC and other PLC + RS 232 cable for MV320
+ 6GF3320-0AC03

power supply
MV320
(6GF3320-0HT01)

5V cable via USB


1m = 6GT2091-7UH10

i.e. S7-1500 CPU CM PtP RS 232 BA +


(6ES7540-1AD00-0AA0) • use an already available and unused USB port or
• standard USB power supply from the market

84 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


Interfaces for general purpose serial devices (RS232 or RS422) Serial device Options
System Interfaces powered through connection cable

PROFINET & Ethernet/IP


A maximum of Provided power from CM:
Communication Modules Always refer to
1 serial device at RF185C, 24 Volt
the manual of
up to 800 mA for each device
2 serial devices at RF186C/CI, the connected
4 serial devices at RF188C/CI** 5 Volt * (only when RS232 is used)
up to 500 mA for each device device
may be connected via RS232* or RS422
RF185C RF186C RF188C
(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40)
+ Customer assembled cable: CM connector (6GT2090-0BE00)
Bulk cable i.e. 50 m (6GT2 090-4AN50)
+
Device connector (Order via distributor)
Examples of devices:
Additional IOs
Types of IO-Link
+ RF18xCI to sensor
+ I/O module
IO-extension module Cabling:
Sensor cable from 6ES7 14….. (up to 8xDI + 8xDO)
RF186CI RF188CI 0.5 to 15 m available
(6GT2 002-0JE50) (6GT2 002-0JE60) See page 88 for detailed information i.e. scanners, handheld devices Use a bulk cable (i.e.
(e.g. 2 m = 6XV1801-2CH20)
6GT2090-4AN50) and
Or one assemble left side the
Standard sensor CM connector
6GT2090-0BE00
Or one The right side
Actor
Serial device connector you may
order via distributor for
electronic components
powered with external power supply
PROFIBUS Or
A maximum of 2 readers may be connected Provided power:

+ RF166C to serial device via RS232* or RS422


Customer assembled cable: CM connector (6GT2090-0BE00)
+ Always customer
specific power supply Use the cable
delivered by th device,
Bulk cable i.e. 50 m (6GT2 090-4AN50) cut the left side
connector and replace
RF166C (DP-V1) Device connector (Order via distributor)
Examples of devices: it with a plug
Communication Module 6GT2090-0BE00
(6GT2 002-0EE20)

Or (only RS422)
ET200pro PROFIBUS DP-V1
Interface module
RF170C A maximum of 2 readers may be connected
You may use one of
the standard reader

ET200pro
ET200pro PROFINET
Interface module
+ + RF170C to serial device via RS232* or RS422 + cable 6GT2891-4F,
cut and replace the
connector on the right
side (device side)
via PROFIBUS ET200pro PROFINET
RF170C
CPU module i.e. robots, motors, tooling machines
or PROFINET Communication module
(6GT2 002-0HD01)
Up to 9 x 170C modules per
or S7 PLC ET200pro rack Connection block
(6GT2 002-1HD01)

85 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


Bill of Materials Guides

86 Unrestricted | © Siemens 2023 | All rights reserved.


RF18xC /CI Bill of Materials Guide
The RF18xC is a communication module that can connect to Ethernet-based RF185C Reade RF186C/C Reade RF188C/CI Reade
Bus Topology Concept r I
networks via an M12 d-coded connector. It supports a variety of protocols like r r
PROFINET, Ethernet/IP, OPC UA, TCP/IP. A integrated switch enables star and
line topologies. The module has L-coded M12 connectors for the 24 V power
supply. The power can be transferred to additional loads at a second L-coded 24VDC
female connector. The L-coded connectors can transmit a continuous current of Covering cap
Power
up to 16 A. Covering
PROFINE cap
The designer chooses whether to purchase pre-made network cables or to make
his/her own. Note that no Termination Resistors are required on end-nodes, but T
Description Part Number Notes
covering caps are highly recommended.
Make your own RF18xC to RF reader cables

Description Part Number Notes Refer to the Bulk cable and connectors tables (Pages 92 - 93)

RF185C 6GT2 002-0JE10 1 read/write device or reader Use pre-made RF18xC to RF reader cables
RF186C 6GT2 002-0JE20 2 read/write devices or readers
RF188C 6GT2 002-0JE40 4 read/write devices or readers
RF186CI 6GT2 002-0JE50 2 read/write devices or readers plus sensors 6GT2 891-4FH20 2 meter pre-assembled cable
RF188CI 6GT2 002-0JE60 4 read/write devices or readers plus sensors
can be connected to PROFINET or Ethernet (OPC UA) 6GT2 891-4FH50 5 meter pre-assembled cable
Reader cable R200/ RF300/ MV440
or
Make your own M12 PROFINET connection cables 6GT2 891-4FN10 10 meter pre-assembled cable
Extension cable
for RF200/ RF300/ MV400 /MV500
Ethernet to CM. 2 x M12 6GT2 891-4FN20 20 meter pre-assembled cable
SIMATIC NET Ethernet M12 4-pin connector 6GK1 901-0DB10-6AA0
4-pin connectors needed if loop-through
6GT2 891-4FN50 50 meter pre-assembled cable
RJ45 connector with metal casing and FC connection
6GK1 901-1BB10-2AA0 For connection into standard RJ45-type Ethernet switch Reader cable to RF1000 6GT2891-4UH20 2 meter pre-assembled cable
system, 180° cable outlet

Sold by the meter 5 meter pre-assembled coiled cable with a usable length between 1.6
ETHERNET industrial cable 2x2, Type A, unassembled 6XV1 840-2AH10 Reader cable to MV320 6GT2191-0BH50
and 4 meter
Minimum length 20 m; Maximum length 1000 m

Reader cable MV420 6GF3420-0AC00-2CB0 2 meter pre-assembled cable


Use pre-made M12 PROFINET connection cables
6GF3500-8BA11 0.5 meter pre-assembled cable
Pre-assembled PROFINET cable with 4-pin M12 on both 6XV1 870-8Axxx* …8A = 180°, …8G = 90°
Reader cable MV500
ends 6XV1 870-8Gxxx* 0.3 m– 15 m pre-assembled cable 6GF3500-8BA12 5 meter pre-assembled cable

0.3 m– 15 m pre-assembled cable


Pre-assembled PROFINET cable with 4-pin M12 / RJ45 6XV1871-5Txxx* Additional components
RJ45 for switch / PC / controller
Covering caps for unused M12 ports 3RX9 802-0AA00 1 pack = 10 items
Make your own M12 L-coded power supply connection cables
Labels 10 x 5 mm for CM channel marking 6ES7194-2BA00-0AA0 For additional marking. Per default labels are included in CM package
Power cable For the supply of the 24 VDC power,
6XV1801-2B
(4 wire x 1.5 mm2, trailing type) from 20m up to 1000m
Make your own M12 sensor cable (only RF18xCI variants)

For the loop-through of the 24 VDC power, Sensor Connector at CM-side


M12 L-coded – male connector 6GK1906-0EA00 M12 A-coded – male connector, 4 pin 6GK1 907-0DB10-6AA3
screw joint for wires up to 1.5 mm 2 for cable diameter 6 – 8 mm

Sensor-side connector
For the supply side of 24 VDC power, M12 A-coded – female connector, 4 pin 6GK1 907-0DC10-6AA3
M12 L-coded – female connector 6GK1906-0EB00 for cable diameter 6 – 8 mm
screw joint for wires up to 1.5 mm 2
Sensor cable five wire 6XV1801-2C bulk cable; minimum order 20 meter
Use pre-made M12 L-coded power supply connection cables
Sensor connector at CM-side
Cable for supply voltage with pre- M12 A-coded – male connector, 5 pin, 180° 6GK1 908-0DB10-6AA0 Required for assembling an IO-Link
6XV1801-6Dxxx* Lengths available from 0.5 m up to 15 m
Assembled M12 L-coded connectors 180° port Class B cable

Cable for supply voltage with pre- M12 A-coded – female connector, 5 pin, 180° 6GK1 908-0DC10-6AA0 Sensor connector at sensor-side
6XV1801-6Gxxx* Lengths available from 0.5 m up to 15 m
Assembled M12 L-coded connectors 90°
Use pre-made M12 sensor cable (only RF18xCI variants)
Cable for supply voltage assembled with Length 5 m
M12 A-coded 4pin male connector and 6GT2091-0PH50 Useful to connect the CM directly to a power supply of type IO-Link (port Class B) sensor cable with
6XV1801-2Cxxx* Lengths available from 0.5 m up to 15 m
M12 L-coded connector female at CM side 6GT2898-0ACx0 M12 A-coded 5-pin connectors (male and female)

* These cables are available in various lengths (see catalogue or mall)


87 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF18xCI Bill of Materials Guide, Sensor Cabling
The RF18xCI variants allow the connecting of a variety of IO-Link I/O modules. A
maximum of 8 sensors (inputs) and 8 actors (outputs) may be connected to one
CM. There is no additional configuration necessary for the I/Os. The I/Os can be Bus Topology Concept
used with all available protocols: PROFINET, Ethernet/IP, OPC UA and TCP/IP.
RF186CI Reader RF186CI Reader
Read this page for connecting details.
Sensors, High
Sensors,
power actors
The designer chooses whether to purchase pre-made sensor cable or to make actors
his/her own (see page before)

24VDC Power
Description Part Number Notes *)

RF186CI 6GT2 002-0JE50 2 read/write devices or readers plus sensors PROFINET


RF188CI 6GT2 002-0JE60 4 read/write devices or readers plus sensors
can be connected to PROFINET or Ethernet (OPC UA)

Sensor/actor cabling I/O modules with M8 sensor connectors


+ I/O module to sensor+
6ES7 141-5BF00-0BL0 (8xDI)
6ES7 143-5BF00-0BL0 (4xDI + 4xDO) Use sensor cables from the
sensor market

+ + I/O modules with M12 sensor connectors


6ES7 141-5AH00-0BL0 (8xDI)

RF186CI
RF18xCI to IO-Link
I/O module or
6ES7 143-5AH00-0BL0 (8xDI + 8xDO)
+ I/O module to sensor
+
(6GT2 002-0JE50) sensor, actor
0.5 m = 6XV1801-2CE50
0.5 m = 6XV1801-2CE50 1 m = 6XV1801-2CH10
1 m = 6XV1801-2CH10 1.5 m = 6XV1801-2CH15
1.5 m = 6XV1801-2CH15 2 m = 6XV1801-2CH20
2 m = 6XV1801-2CH20 6ES7 142-5AF00-0BL0 (8xDO, 2A) 3 m = 6XV1801-2CH30
3 m = 6XV1801-2CH30 Extra M12 L-coded power cable needed *) 5 m = 6XV1801-2CH50
5 m = 6XV1801-2CH50 10 m = 6XV1801-2CN10
10 m = 6XV1801-2CN10 15 m = 6XV1801-2CN15
15 m = 6XV1801-2CN15
RF188CI
(6GT2 002-0JE60)

I/O modules with integrated sensor/actor


8WD4428-0BF (SIRIUS Signaling column)
For detailed configuration read manual: https://support.industry.siemens.com/cs/ww/en/view/109758131

3SU1400…. (Pushbuttons and indicator lights from SIRIUS ACT)


3SU1400-1HL10-6AA0 (6xDI + 2xDO)
3SU1400-2HL10-6AA0 (6xDI + 2xDO)
3SU1400-2HK10-6AA0 (6xDI + 2xDO)
3SU1400-2HM10-6AA0 (4xDI + 4xDO)
3SU1400-2HN10-6AA0 (2xDI + 6xDO)
For detailed configuration read manual: https://support.industry.siemens.com/cs/ww/en/view/107542462

*) Some IO modules for high


output current need an extra L-
coded power cable
One standard sensor
6XV1801-6Dxxx from 0.5 to 15 m Or one actor, lamp

88 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF166C Bill of Materials Guide
RF166C RF166C RF166C
The RF166C is a PROFIBUS DP-V1 interface module. The PROFIBUS connection is made via Reader Reader Reader
M12 B-coded connector.
The module has L-coded M12 connectors for the 24 V power supply. The power can be Bus Topology Concept
transferred to additional loads at a second L-coded female connector. The L-coded
connectors can transmit a continuous current of up to 16 A.

The designer chooses whether to purchase pre-made network cables or to make his/her own.
PROFIBUS Bus Termination
Note that another design consideration is whether the RF166C is a PROFIBUS end-node or Covering cap
not. If it is an end-node, a Termination Resistor is required. 24VDC Power

Description0 Part Number Notes Description Part Number Notes

For PROFIBUS DP-V1 networks. Make your own RF166C to RF reader cables
RF166C 6GT2 002-0EE20 2 read/write devices or readers can be connected
The devices may have RS422 or RS232 interface Refer to the Bulk cable and connectors tables (Pages 92- 93)

Make your own M12 PROFIBUS connection cables Use pre-madeRF166C to RF reader cables

For the supply side of the PROFIBUS network. Use 6GT2 891-4FH20 2 meter pre-assembled cable
PROFIBUS M12 connector plug (5
6GK1 905-0EB00 Termination Resistor on the 2nd M12 port if RF166C is
per pack) with socket insert 6GT2 891-4FH50 5 meter pre-assembled cable
an end node Reader cable R200/ RF300/ RF600 /MV440
or
For loop-through side of the PROFIBUS network. Both 6GT2 891-4FN10 10 meter pre-assembled cable
PROFIBUS M12 connector plug (5 per 6GK1 905-0EA00 Extension cable
ports are used. No Termination Resistor needed for that
pack) with pin insert for RF200/ RF300/ RF600/ MV400 /MV500
RF166C 6GT2 891-4FN20 20 meter pre-assembled cable

Sold by the meter 6GT2 891-4FN50 50 meter pre-assembled cable


POFIBUS standard non-assembled cable 6XV1 830-0EH10 Minimum length 20 m
Maximum length 10000 m Reader cable to RF1000 6GT2891-4UH20 2 meter pre-assembled cable

M12 Termination Resistor for PROFIBUS (5 per 5 meter pre-assembled coiled cable with a usable length between 1.6 and 4
6GK1 905-0EC00 Required if RF166C is an end-node Reader cable to MV320 6GT2191-0BH50
pack) meter

Use pre-made M12 PROFIBUS connection cables Reader cable MV420 6GF3420-0AC00-2CB0 2 meter pre-assembled cable

6GF3500-8BA11 0.5 meter pre-assembled cable


PROFIBUS cable with pre- See Online Mall (http://mall.automation.siemens.com)
6XV1 830-3Dxxx* Reader cable MV500
assembled M12 connectors Lengths available from 0.5 m up to 15 m
6GF3500-8BA12 5 meter pre-assembled cable

M12 Termination Resistor for Additional components


6GK1 905-0EC00 Required if RF166C is an end-node
PROFIBUS (5 per pack)
Covering caps for unused M12 ports 3RX9 802-0AA00 1 pack = 10 items
Make your own M12 L-coded power supply connection cables
Labels 10 x 5 mm for CM channel marking 6ES7194-2BA00-0AA0 For additional marking. Per default labels are included in CM package
Power cable For the supply of the 24 VDC power,
6XV1801-2B
(4 wire x 1.5 mm2, trailing type) from 20m up to 1000m Make your own M12 Ethernet connection cables (needed for web-based management)
For the loop-through of the 24 VDC power,
M12 L-coded – male connector 6GK1906-0EA00 Ethernet to RF166C. 2 x M12
screw joint for wires up to 1.5 mm 2 SIMATIC NET Ethernet M12 4-pin connector 6GK1 901-0DB10-6AA0
4-pin connectors needed if loop-through

For the supply side of 24 VDC power,


M12 L-coded – female connector 6GK1906-0EB00 RJ45 connector with metal casing and FC connection system, 180°
screw joint for wires up to 1.5 mm 2 6GK1 901-1BB10-2AA0 For connection into standard RJ45-type Ethernet switch
cable outlet

Use pre-made M12 L-coded power supply connection cables Sold by the meter
ETHERNET industrial cable 2x2, Type A, unassembled 6XV1 840-2AH10
Minimum length 20 m; Maximum length 1000 m
Cable for supply voltage with pre-
6XV1801-6Dxxx* Lengths available from 0.5 m up to 15 m
Assembled M12 L-coded connectors 180° Use pre-made M12 Ethernet connection cables (needed for web-based management)

Cable for supply voltage with pre-


6XV1801-6Gxxx* Lengths available from 0.5 m up to 15 m Pre-assembled Ethernet cable with 4-pin M12 at RF166C and RJ45 at 2 m– 15 m pre-assembled cable
Assembled M12 L-coded connectors 90° 6XV1871-5Txxx*
computer Use this cable type if the wbm of the RF166C is directly connected to a PC
Cable for supply voltage assembled with Length 5 m
M12 A-coded 4pin male connector and 6GT2091-0PH50 Useful to connect the CM directly to a power supply of 0.3 m– 15 m pre-assembled cable
M12 L-coded connector female at CM side type 6GT2898-0ACx0 Pre-assembled PROFINET cable with 4-pin M12 on both ends 6XV1 870-8xxx*
Use this cable type if the RF166C is connected to a IP 65 switch

* These cables are available in various lengths (see catalogue or mall)


89 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


RF360R Bill of Materials Guide
RF360R RF360R RF360R
The RF360R is a reader from the RF300 family that can connect to Ethernet-
based networks via an M12 d-coded connector. It supports a variety of protocols Bus Topology Concept
like PROFINET, Ethernet/IP, OPC UA, TCP/IP. A integrated switch enables star
and line topologies. The module has L-coded M12 connectors for the 24 V power
supply. PROFINET
The designer chooses whether to purchase pre-made network cables or to make Covering cap

his/her own. Note that no Termination Resistors are required on end-nodes, but
covering caps are highly recommended. 24VDC Power

Description Part Number Notes Description Part Number Notes

RF360R 6GT2801-5BA30 RF300 Reader with integrated antenna Additional components

Covering caps for unused M12 ports 3RX9 802-0AA00 1 pack = 10 items

Make your own M12 PROFINET connection cables

Ethernet to reader. 2 x M12


SIMATIC NET Ethernet M12 4-pin connector 6GK1 901-0DB10-6AA0
4-pin connectors needed if loop-through

RJ45 connector with metal casing and FC connection


6GK1 901-1BB10-2AA0 For connection into standard RJ45-type Ethernet switch
system, 180° cable outlet

Sold by the meter


ETHERNET industrial cable 2x2, Type A, unassembled 6XV1 840-2AH10
Minimum length 20 m; Maximum length 1000 m

Use pre-made M12 PROFINET connection cables

Pre-assembled PROFINET cable with 4-pin M12 on both 6XV1 870-8Axxx* …8A = 180°, …8G = 90°
ends 6XV1 870-8Gxxx* 0.3 m– 15 m pre-assembled cable

0.3 m– 15 m pre-assembled cable


Pre-assembled PROFINET cable with 4-pin M12 / RJ45 6XV1871-5Txxx*
RJ45 for switch / PC / controller

Make your own M12 L-coded power supply connection cables

Power cable For the supply of the 24 VDC power,


6XV1801-2B
(4 wire x 1.5 mm2, trailing type) from 20m up to 1000m

For the supply side of 24 VDC power,


M12 L-coded – female connector 6GK1906-0EB00
screw joint for wires up to 1.5 mm 2

Use pre-made M12 L-coded power supply connection cables

Cable for supply voltage with pre-


6XV1801-6Dxxx* Lengths available from 0.5 m up to 15 m
Assembled M12 L-coded connectors 180°

Cable for supply voltage with pre-


6XV1801-6Gxxx* Lengths available from 0.5 m up to 15 m
Assembled M12 L-coded connectors 90°

Cable for supply voltage assembled with Length 5 m


M12 A-coded 4pin male connector and 6GT2091-0PH50 Useful to connect the reader directly to a power supply of type
M12 L-coded connector female at CM side 6GT2898-0ACx0

* These cables are available in various lengths (see catalogue or mall)


90 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


Bulk Cable and Connectors

91 Unrestricted | © Siemens 2023 | All rights reserved.


Bulk Cable and Connectors
RF166C RF120C RS232 to PC Ethernet to PC RF170C RF185C, RF186C/CI, RF188C/CI

RF200
For IP 67 Master with M12:
For IP 20 Master with screws or push in:
RF2x0R 6XV1 801-2C (5 wire sensor cable; minimum order 20 m)
6XV1 801-2C (5 wire sensor cable; minimum order 20 m)
(IO-Link) 6GK1 908-0DC10-6AA0 (reader connector; never assemble pin 2)
6GK1 908-0DC10-6AA0 (reader connector; never assemble pin 2)
6GK1 908-0DB10-6AA0 (IO-Link master connector)

RF2X0R 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable)
6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable)
RF210M Not applicable
6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable)
(RS422) (reader connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector)
(CM type) 6GT2090-0BE00 (CM connector) 9-pin submin-D/M (CM connector)1 PC side: interface converter RS422/ RS232 6GT2090-0BE00 (CM connector) 6GT2090-0BE00 (CM connector)

RF240R
RF250R 6GT2 090-4AN50 (50 m cable)
6GT2 090-4AT12 (120 m cable)
RF260R
Not applicable Not applicable 6GT2 090-4AT80 (800 m cable) Not applicable Not applicable Not applicable
RF285R 6GT2090-0BD00 (reader connector)
RF290R 6GT2 490-1AA00 (PC connector)
(RS232)

RF300
6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable)
RF3x0R 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable)
(RS422) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) Not applicable 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable)
6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector)
(CM type)
6GT2090-0BE00 (CM connector) 9-pin submin-D/M (CM connector)1 PC side: interface converter RS422/ RS232 6GT2090-0BE00 (CM connector) 6GT2090-0BE00 (CM connector)

6GT2 090-4AN50 (50 m cable)


6GT2 090-4AT12 (120 m cable)
RF38xR Not applicable Not applicable 6GT2 090-4AT80 (800 m cable) Not applicable Not applicable Not applicable
(RS232) 6GT2090-0BD00 (reader connector)
6GT2 490-1AA00 (PC connector)

RF600
6XV1 840-2AH10 (>20 m cable)
RF650R Not applicable Not applicable Not applicable 6GK1901-1BB10-2AA0 (RJ45, reader connector Not applicable Not applicable
+ network connector)

RF610R/ 6GT2 090-4AN50 (50 m cable) 6XV1 840-2AH10 (>20 m cable)


6GT2 090-4AT12 (120 m cable) 6GK1901-0DB20-6AA0 (M12 Plug, reader
RF615R/ Not applicable Not applicable connector) Not applicable Not applicable
6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00
RF680R/ (reader connector) 6GK1901-1BB10-2AA0 (RJ45, network
RF685R 6GT2090-0BE00 (CM connector) connector)

RF1000
Always use assembled cables:
RF1040R/ Always use assembled cables: Always use assembled cables: Always use assembled cables Always use assembled cables:
6GT2891-2UH30 (3m, open) Not applicable
RF1070R 6GT2891-4UH20 (2m) 6GT2891-6UH20 (2m) 6GT2891-4UH20 (2m) 6GT2891-4UH20 (2m)
6GT2891-7UH18 (1.8m, sub-D)

92 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide


Bulk Cable and Connectors

RF166C RF120C RS232 to PC Ethernet to PC RF170C RF185C, RF186C/CI, RF188C/CI

MV500
Always use reader-side assembled cables: Always use reader-side assembled cables: Always use reader-side assembled cables: Always use reader-side assembled cables with 90° Always use reader-side assembled cables: Always use reader-side assembled cables:
10 m = 6GF3 500-8BA21 10 m = 6GF3 500-8BA21 10 m = 6GF3 500-8BA21 angled connector 10 m = 6GF3 500-8BA21 10 m = 6GF3 500-8BA21
10 m UL = 6GF3500-8BA23 10 m UL = 6GF3500-8BA23 10 m UL = 6GF3500-8BA23 100 MB: 10 m UL = 6GF3500-8BA23 10 m UL = 6GF3500-8BA23
30 m = 6GF3500-8BA41 30 m = 6GF3500-8BA41 30 m = 6GF3500-8BA41 6XV1 870-8xxx (0.3 to 15 m) 30 m = 6GF3500-8BA41 30 m = 6GF3500-8BA41
30 m UL = 6GF3500-8BA43 30 m UL = 6GF3500-8BA43 30 m UL = 6GF3500-8BA43 6GK1 901-1BB10-2AA0 (RJ45, 2x2) 30 m UL = 6GF3500-8BA43 30 m UL = 6GF3500-8BA43
9-pin submin-D/M (CM connector)1 6GK1 901-0DB20-6AA0 (M12, 2x2)
MV500 6GT2090-0BE00 (CM connector) 6GT2 490-1AA00 (PC connector)
1000 MB:
6GT2090-0BE00 (CM connector) 6GT2090-0BE00 (CM connector)
6XV1 878-5Gxxx (0.3 to 15 m)
6GK1 901-1BB12-2AA0 (RJ45, 4x2)
6GK1 901-0DB30-6AA0 (M12, 4x2)
The connectors (M12, RJ45) can be assembled after
cutting one connector of an existing cable

1. Order via distributor for electronic components

Power & Control-side Networking Components


RF166C RF120C RS232 to PC RF185C, RF186C/CI, RF188C/CI RF360R RF600 MV500

6GT2 090-4AN50 (50 m cable) Always use reader-side assembled cables (M12,
See RF166C See RF18xC See RF360R 6GT2 090-4AT12 (120 m cable) 12pin)
Direct with S7-1200 and power-side open ends:
Cable & Connec-tors Bill of Materials Guide assembly
See individual readers above bill of materials guide bill of materials guide 6GT2 090-4AT80 (800 m cable)
Page 89 10 m = 6GF3 500-8BA21
page 87 page 90 6GT2090-0BD00 (reader connector)
30 m = 6GF3 500-8BA41
6GK1907-0DB10-6AA3 (power supply)

93 Unrestricted | © Siemens 2023 | All rights reserved.

SIMATIC Ident Configuration Guide

You might also like