SINAMICS G110 Inverter Chassis Units 0.12 kW to 3 kW Order No.: E86060-K5511-A111-A2 (German) E86060-K5511-A111-A2-7600 (English) SINAMICS G130 Drive Converter Chassis Units SINAMICS G150 Drive Converter Cabinet Units Order No.: E86060-K5511-A101-A3 (German) E86060-K5511-A101-A3-7600 (English) SINAMICS S120 Vector Control Drive System Order No.: E86060-K5521-A111-A1 (German) E86060-K5521-A111-A1-7600 (English) SINAMICS S120 Servo Control Drive System D 21.2 D 11 D 11.1
D 21.1
Order No.: E86060-K5521-A121-A1-7600 (English) SINAMICS S150 Drive Converter Cabinet Units 75 kW to 1200 kW Order No.: E86060-K5521-A131-A1 (German) E86060-K5521-A131-A1-7600 (English) Catalog CA 01 CA 01 The Offline Mall of Automation and Drives Order No.: CD-ROM: E86060-D4001-A100-C4 (German) CD-ROM: E86060-D4001-A110-C4-7600 (English) DVD: E86060-D4001-A500-C4 (German) DVD: E86060-D4001-A510-C4-7600 (English) A&D Mall Internet: http://www.siemens.com/automation/mall D 21.3
Trademarks
All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.
SINAMICS GM150 SINAMICS SM150 Medium-Voltage Converters 0.8 MVA to 28 MVA Catalog D 12 2006
Introduction
1 2 3 4
Description of options
5
Accessories
6
Configuration
7
The products and systems described in this catalog are produced/distributed in accordance with the requirements of a quality management system which has been certified to DIN EN ISO 9001 and DIN EN ISO 14001 (Certificate Registration No. 002241 QM UM). The certificate is recognized in all IQNet countries.
8
Appendix
We would like to welcome you to Automation and Drives and our comprehensive range of products, systems, solutions and services for production and process automation and building technology worldwide. With Totally Integrated Automation and Totally Integrated Power, we deliver solution platforms based on standards that offer you a considerable savings potential. Discover the world of our technology now. If you need more detailed information, please contact one of your regional Siemens partners. They will be glad to assist you.
1/2
Siemens D 12 2006
Siemens D 12 2006
1/3
With the launch of Totally Integrated Automation, we were the first ones on the market to consistently implement the trend from equipment to an integrated automation solution, and have continuously improved the system ever since. Whether your industry is process- and production-oriented or a hybrid, Totally Integrated Automation is a unique common solution platform that covers all the sectors. Totally Integrated Automation is an integrated platform for the entire production line - from receiving to technical processing
Ethernet
Material Management
Equipment Management
Control
SIMATIC Software
Idsl nua r t i
Industrial Ethernet
Ethernet
Safety Integrated
PROCESS FIELD
PROFIBUS
PC-based Automation
AS-Interface
GAMMA instabus
1/4
Siemens D 12 2006
and production areas to shipping. Thanks to the systemoriented engineering environment, integrated, open communications as well as intelligent diagnostics options, your plant now benefits in every phase of the life cycle. In fact, to this day we are the only company worldwide that can offer a control system based on an integrated platform for both the production and process industry.
SIMATIC IT Framework
Detailed Production Scheduling Laboratory Information Management System
HART
PROFIBUS PA
SIMODRIVE
SINAMICS
SINAMICS
Siemens D 12 2006
1/5
Introduction
Overview
The SINAMICS drive family
SINAMICS G
SINAMICS S
Extrusion
Forming/shaping
Pumps/fans
Packaging
Conveyor systems
Applications SINAMICS is the new family of Siemens drives designed for machine and plant engineering applications. SINAMICS offers solutions for all drive tasks: 7 Simple pump and fan applications in the process industry. 7 Complex individual drives in centrifuges, presses, extruders, elevators, as well as conveyor and transport systems. 7 Drive line-ups in textile, plastic film and paper machines, as well as in rolling mill plants. 7 Highly dynamic servo drives for machine tools, as well as packaging and printing machines. Versions Depending on the application, the SINAMICS range offers the ideal version for any drive task. 7 SINAMICS G is designed for standard applications with induction motors. These applications have less stringent requirements regarding the dynamics and accuracy of the motor speed. 7 SINAMICS S handles complex drive tasks with synchronous/ induction motors and fulfills stringent requirements regarding: - dynamics and accuracy - integration of extensive technological functions in the drive control system
Platform concept and Totally Integrated Automation All SINAMICS versions are based on a platform concept. Common hardware and software components, as well as standardized tools for design, configuration and commissioning tasks, ensure high-level integration across all components. SINAMICS handles a wide variety of drive tasks with no system gaps. The different SINAMICS versions can be easily combined with each other. SINAMICS is part of the Siemens Totally Integrated Automation concept. Integrated SINAMICS systems covering configuration, data storage and communication at automation level, ensure low-maintenance solutions with the SIMATIC, SIMOTION and SINUMERIK control systems.
1/6
Siemens D 12 2006
Introduction
Overview
The SINAMICS drive family
SINUMERIK SINUMERIK
SINAMICS
Quality in accordance with DIN EN ISO 9001 SINAMICS conforms with the most exacting quality requirements. Comprehensive quality assurance measures in all development and production processes, ensure a consistently high level of quality. Of course, our quality assurance system is certified by an independent authority in accordance with DIN EN ISO 9001.
Siemens D 12 2006
1/7
Introduction
Overview
The SINAMICS drive family
SINAMICS for every output rating
G110
G120
S120
S120
S120
G150/S150
GM150/SM150
0.12 kW
1.5 MW
30 MW
100 MW
G110
G120
G130 G150/GM150
S120
S120
S120
S120
S120
S120
Basic functionality
G110
G120
G130
G150/GM150
S150
SM150
S120
S120
S120
S120
Single drives
Tailored to the respective areas of application, SINAMICS is divided into the family members: 7 SINAMICS G110 the versatile drive for low power ranges 7 SINAMICS G130 and SINAMICS G150 the universal drive solution for high-performance single drives 7 SINAMICS S120 the flexible, modular drive system for demanding tasks 7 SINAMICS S150 the advanced drive solution for high-performance single drives 7 SINAMICS GM150 the universal drive solution for single drives in the medium-voltage range 7 SINAMICS SM150 the advanced drive solution for single and multi-motor drives in the medium-voltage range
The SINAMICS range is characterized by the following system features: uniform functionality based on platform concept uniform engineering high degree of flexibility and combination wide power range designed for global use SINAMICS Safety Integrated increased economy and effectivity versatile interfacing facilities to host controllers Totally Integrated Automation
1/8
Siemens D 12 2006
G_D211_EN_00098
Introduction
Overview
SINAMICS GM150/SINAMICS SM150 Medium-Voltage Converters
Overview
The SINAMICS GM150 and SINAMICS SM150 converters are the expansion of the SINAMICS drive family in the medium voltage range. They are supplied as ready-to-connect cabinet units. SINAMICS GM150 SINAMICS GM150 converters are designed as single-motor drives for applications with square-law and constant load characteristics without regenerative feedback. SINAMICS SM150 SINAMICS SM150 converters are designed for demanding single and multi-motor applications and meet the following requirements: High dynamic response Operation at low frequency Four-quadrant operation
Typical applications: Pumps and fans Compressors Extruders and mixers Mills Marine drives The motor-side inverters (Motor Modules) have IGBT power semiconductors in the lower power range to 10 MVA and IGCT power semiconductors in the upper power range from 10 MVA to 28 MVA.
SINAMICS GM150 IGBT Line Module (line-side rectifier) Basic Line Module, 12-pulse (two-quadrant operation) Basic Line Module, 24-pulse (two-quadrant operation) Active Line Module (four-quadrant operation) Motor Module (motor-side inverter) Voltage range Power range (typ.) Cooling method Air cooling Water cooling Control modes Induction motor Synchronous motor, separately excited Synchronous motor, permanently excited Sine-wave filter DC bus configuration with several Motor Modules on one common DC bus Standard Option Option Standard Standard 2.3 kV to 6.6 kV 0.8 MVA to 10 MVA Standard
Typical applications: Rolling mill drives (cold, hot) Mine hoist drives Test stands Conveyor belts Both the line-side inverters (Active Line Modules) and the motorside inverters are equipped with IGCT power semiconductors.
Option for 2.3 kV to 4.16 kV Standard for 6.0 kV and 6.6 kV and parallel connection
Standard
Benefits
Low-cost: all the way from planning to service Simple and uncomplicated in every regard: engineering, integration, operation and diagnostics 7 High availability: robust and reliable components, easy installation, high service-friendliness
7 7
Siemens D 12 2006
1/9
Introduction
Overview
Further members of the SINAMICS drive family
Overview
SINAMICS G110 SINAMICS G130/G150 SINAMICS S120 SINAMICS S150
The versatile drive for low power ranges Main applications Machines and plants for industrial and commercial applications
Machines and plants for in- Machines and plants in the Machines and plants in the process and production industrial applications (packprocess and production dustry, food, beverages and aging, plastics, textile, printindustry, water/waste, power tobacco, automotive and ing, wood, glass, ceramics, stations, oil and gas, petrosteel industry, mining/openpresses, paper, lifting equipchemicals, chemical raw cast mining, shipbuilding, ment, semiconductors, automaterials, paper, cement, lifting equipment/conveyors mated assembly and testing stone, steel equipment, handling) Pumps and fans Compressors Extruders and mixers Mills Motion Control applications (e.g. positioning, synchronous operation, ) Technological applications Test bay drives Centrifuges Elevators and cranes Cross cutters and shears Conveyor belts Presses Cable winches
Application examples Pumps and fans Auxiliary drives Conveyor belts Billboards Door/gate operating mechanisms Centrifuges Highlights Compact Flexible adaptation to different applications Simple, fast commissioning Clear terminal layout Optimum interaction with SIMATIC and LOGO! Space-saving Low-noise Simple, fast commissioning SINAMICS G130: modular components SINAMICS G150: readyto-connect cabinet unit Optimum interaction with SIMATIC For universal use Flexible and modular Scalable in terms of power, function, number of axes, performance Simple, fast commissioning, auto-configuration Innovative system architecture Wide range of motors Optimum interaction with SIMOTION and SIMATIC SINAMICS Safety Integrated Four-quadrant operation as standard High control accuracy and dynamic response Almost no line harmonic distortions Tolerant to fluctuations in line voltage Option of power factor compensation Simple, fast commissioning Ready-to-connect cabinet unit Optimum interaction with SIMATIC
1/10
Siemens D 12 2006
2
2/2 2/2 2/3 2/6 2/8 2/9 2/10 2/11 2/12 2/17 2/17 2/18 2/18 2/19 Overview Benefits Design Function Selection and ordering data Air cooling, without sine-wave filter Air cooling, with sine-wave filter Water cooling, without sine-wave filter Water cooling, with sine-wave filter Options Technical data General technical data Control properties Ambient conditions Installation conditions and derating data Converter-related technical data Air cooling, without sine-wave filter Air cooling, with sine-wave filter Water cooling, without sine-wave filter Water cooling, with sine-wave filter 2/21 2/35 2/49 2/62
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Overview
IGBT converters are available for the following voltages and power ranges:
Rated output voltage kV 2.3 3.3 4.16 6.0 6.6 Type rating with air cooling MVA 1.0 to 2.4 1.0 to 6.3 1.3 to 7.9 0.8 to 5.0 0.9 to 5.5 with water cooling MVA 2.0 to 3.2 2.0 to 8.0 2.0 to 10.1 1.8 to 7.3 1.9 to 8.0
Global use SINAMICS GM150 converters in IGBT version are manufactured to international standards and regulations, making them ideally suited for global use. These converters are also available in a UL-listed version and in a marine version (meeting the requirements of all major classification organizations).
Benefits
7 7 7
SINAMICS GM150 converters in IGBT version can be optimally combined with Siemens converter motors. Sine-wave filters are not required in this case. This ensures that the drive solution is particularly cost-effective, compact and efficient. With the sine-wave filter available as an option, the converters offer the best conditions on the market for the operation of standard motors. This makes them ideally suited for the retrofitting of existing systems from fixed-speed drives to variable speed drives. SINAMICS GM150 converters in IGBT version offer economic drive solutions that can be matched to customers specific requirements by chosing from the wide range of available components and options.
Compact design and high flexibility in configuration ensures easy plant integration Easy operation and monitoring on the convenient operator panel Easy and reliable operation through integrated maintenance functions: the converter signals early and automatically if maintenance is required or components need to be exchanged High robustness and reliability due to the use of HV-IGBT technology and fuseless design combined with intelligent reaction to external disturbances Can be easily integrated into automation solutions due to PROFIBUS interface supplied as standard and various analog and digital interfaces High level of service-friendliness through innovative power section design with plug-in power cards and easy access to all components
2/2
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Design
SINAMICS GM150 converters in IGBT version are available with a 12-pulse or 24-pulse Basic Line Module. The 12-pulse version is standard for smaller output ratings with voltages of 2.3 kV, 3.3 kV and 4.16 kV. For higher output ratings and for voltages of 6.0 kV and 6.6 kV, two Basic Line Modules and two Motor Modules are connected in parallel with a common DC link or two Line Modules are connected in series (24-pulse Basic Line Modules). The 24-pulse Basic Line Module is optionally available for smaller output ratings with voltages of 2.3 kV, 3.3 kV and 4.16 kV. HV-IGBT power semiconductors mounted on plug-in, easy to change power cards are used in the Motor Modules. Both line and motor connections can be optionally realized from bottom or top. The converter cabinet consists of a section for the Basic Line Module, a section for the Motor Module and the control section.
G_D012_EN_00001
2
Basic Line Module Motor Module Control Power card
50/60 Hz 3 AC 2.3 kV to 36 kV
DC link capacitors
Motor
Block diagram Siemens D 12 2006
2/3
G_D012_EN_00002
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Design (continued)
The following circuit designs are available for SINAMICS GM150 in IGBT version.
G_D012_XX_00003
24-pulse infeed through series connection of two Basic Line Modules: option N15, standard for 6.0 kV and 6.6 kV
G_D012_XX_00006
G_D012_XX_00004
Power increased by parallel connection of Basic Line Modules and Motor Modules on a common DC bus for 3.3 kV and 4.16 kV (24-pulse infeed as standard)
Power increased by parallel connection of Motor Modules on a common DC bus for 6.0 kV and 6.6 kV (24-pulse infeed as standard)
2/4
Siemens D 12 2006
G_D012_XX_00005
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Design (continued)
5 6
G_D012_XX_00007
Basic circuit with sine-wave filter for operating standard motors (option Y15)
24-pulse infeed through series connection of two Basic Line Modules: option N15, standard for 6.0 kV and 6.6 kV; in this case with sine-wave filter for operating standard motors (option Y15)
G_D012_XX_00008
G_D012_XX_00030
Parallel connection with sine-wave filter for operating standard motors for 3.3 kV and 4.16 kV (option Y15)
Parallel connection with sine-wave filter for operating standard motors for 6.0 kV and 6.6 kV (option Y15)
Note: The motor cables are brought together in the motor terminal box.
Note: The motor cables are brought together in the motor terminal box.
G_D012_XX_00033
Siemens D 12 2006
2/5
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Function
Characteristic features
SINAMICS GM150 in IGBT version Line Module (line-side rectifier) Basic Line Module, 12-pulse (two-quadrant operation) Basic Line Module, 24-pulse (two-quadrant operation) Motor Module (motor-side inverter) Voltage range Power range (typ.) Cooling method Air cooling Water cooling Control modes Induction motor Synchronous motor, separately excited Sine-wave filter Standard Option Option Standard Standard 2.3 kV to 6.6 kV 0.8 MVA to 10 MVA Standard Option for 2.3 kV to 4.16 kV Standard for 6 kV and 6.6 kV and parallel connection
Setpoint input
Ramp-function generator
Operating hours and switching cycle The operating hours of the fans are detected and logged so that preventive maintenance or replacements counter can be performed. The switching cycles of the circuit-breaker are detected and added up, to form the basis of preventive maintenance work. Detection of actual motor speed (option) Operator protection The SMC30 Sensor Module Cabinet-Mounted can be used to detect the actual motor speed. The signals from the rotary pulse encoder are converted here and made available for evaluation via the DRIVE-CLiQ interface of the controller. The cabinet doors of the power sections are fitted with electromagnetic locks. This prevents the cabinet doors from being opened while hazardous voltages are present inside the cabinet.
2/6
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Function (continued)
Software and protection functions
SINAMICS GM150 in IGBT version EMERGENCY STOP button Description The converters are equipped as standard with an EMERGENCY STOP button with protective collar which is fitted in the cabinet door. The contacts of the pushbutton are connected in parallel to the terminal block so they can be integrated in a protection concept on the plant side. EMERGENCY STOP category 0 is set as standard for an uncontrolled shutdown (DIN EN 60204-1/VDE 0113-1 (IEC 60204-1)). The function includes voltage disconnection of the converter output through the circuit-breaker. Consequently the motor coasts down. EMERGENCY STOP category 1 is optionally available for a controlled shutdown. The converters feature insulated monitoring of the whole galvanic network from the secondary side of the transformer to the stator windings of the motor. An extensive package of options for I/O monitoring (from the transformer and the motor through to the auxiliaries) is available. In addition it is possible to monitor the temperature with thermocouples or PT100 resistors. A warning message is issued first when the overtemperature threshold responds. If the temperature rises further, either a shutdown is carried out or automatic influencing of the output current so that a reduction in the thermal load is achieved. Following elimination of the cause of the fault (e.g. improvement of the ventilation), the original operating values are automatically resumed. For example, if air-cooled converters with filter mats are used, the pollution of the filter mats is monitored and reported by differential pressure measurement. In the case of water-cooled converters, the water temperature and flow rate are detected at several points in the cooling circuit and evaluated. An extensive self-diagnostics protects the converter and reports faults. If grounding on the line or motor side is required for safety and protection reasons, a motor-operated grounding switch can be ordered. For safety reasons, the converter controller locks these grounding switches against activation while voltage is still present. The control is integrated into the protection and monitoring chain of the converter. The grounding switches are inserted automatically when the standard grounding switches of the DC link are inserted. For applications in which the existing circuit-breaker has no undervoltage coil and cannot be retrofitted there are capacitor trip devices available for 110 to 120 V DC and for 230 V DC. They ensure that the circuit-breaker on the plant side can still be safely disconnected even if there is a power failure or the normal OFF command is not effective, e.g. because of a wire break.
AOP30 operator panel It has the following features and characteristics: graphical LCD display with backlighting for plain-text display and a bar display of process variables LEDs for displaying the operational status help function describing causes of and remedies for faults and alarms keypad for operational control of a drive local/remote switchover for selecting the input point (priority assigned to operator panel or customers terminal block/ PROFIBUS) numeric keypad for input of setpoint or parameter values function keys for prompted navigation in the menu two-stage safety strategy to protect against accidental or unauthorized changes to settings. Operation of the drive from the operator panel can be disabled by a password, ensuring that only parameter values and process variables can be displayed in the panel. A password can be used to prevent the unauthorized modification of converter parameters. The operator panel languages - English, German, Spanish and Chinese - are stored on the CompactFlash card of the Control Unit. The AOP30 operator panel is fitted into the cabinet door of the SINAMICS GM150 for operation, monitoring and commissioning.
Siemens D 12 2006
2/7
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
kVA 1000 1200 1400 1600 1800 2000 2200 2400 1000 1300 1500 1700 2000 2300 2600 2900 3100 3400 3800 4100 4600 5100 5700 6300 1300 1600 1900 2200 2500 2900 3200 3600 4000 4300 4800 5200 5800 6500 7200 7900
kW 820
hp 1000
A 250 300 350 400 450 500 550 600 180 220 260 300 350 400 450 500 550 600 2 330 2 360 2 405 2 450 2 500 2 550 180 220 260 300 350 400 450 500 550 600 2 330 2 360 2 405 2 450 2 500 2 550
Fig. No. $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ & & & & & & $ $ $ $ $ $ $ $ $ $ & & & & & &
kVA 800 1000 1200 1600 1900 2100 2300 2500 2800 3100 3400 3800 4200 4600 5000 900 1100 1400 1700 2100 2300 2600 2800 3100 3400 3700 4200 4600 5100 5500
kW 700 850
hp 900 1250
A 80 100 120 150 180 200 225 245 270 2 148 2 163 2 183 2 203 2 223 2 240 80 100 120 150 180 200 225 245 270 2 148 2 163 2 183 2 203 2 223 2 240
Fig. No. % % % % % % % % % ( ( ( ( ( ( % % % % % % % % % ( ( ( ( ( (
Output voltage 2.3 kV 1000 1250 1150 1500 1300 1750 1500 2000 1650 2250 1800 2500 2000 2750 850 1000
1050 1500 1300 1750 1550 2000 1750 2250 1950 2500 2100 2750 2350 3000 2550 3500 2800 3750 3200 4000 3500 4500 3900 5000 4200 5500 750 950 1000 1250
Output voltage 3.3 kV 1050 1250 1250 1500 1400 2000 1650 2250 1900 2500 2150 3000 2400 3250 2650 3500 2850 3750 3100 4000 3400 4500 3900 5000 4300 6000 4800 6500 5300 7000 1000 1500 1300 1750 1550 2000 1800 2500 2100 3000 2400 3250 2700 3500 3000 4000 3300 4500 3600 5000 4000 5500 4300 6000 4900 6500 5400 7000 6000 8000 6600 9000
1150 1500 1400 2000 1700 2250 1900 2500 2150 2750 2300 3000 2600 3500 2800 3750 3100 4000 3500 4500 3900 5000 4200 5500 4600 6000
2/8
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
kVA 850 1000 1150 1300 1450 1650 1850 2000 850 1100 1250 1450 1700 1950 2250 2450 2650 2900 3250 3500 3900 4350 4850 5350 1100 1350 1600 1850 2100 2450 2650 3050 3400 3600 4050 4400 4900 5500 6050 6650
kVA 650 850 1000 1250 1500 1650 1850 2050 2250 2450 2700 3050 3350 3700 4000 700 850 1050 1300 1550 1700 1950 2100 2300 2550 2800 3150 3500 3800 4200
1000 96
1100 1500 330 1200 1600 370 1400 1750 420 1500 2000 460 1650 2250 500 700 900 900 150
1050 1250 120 1250 1500 144 1400 1750 160 1550 2000 180 1700 2250 196 1850 2500 216 2000 2750 236 2250 3000 260 2500 3250 292 2800 3750 324 3000 4000 356 3300 4500 384 550 700 850 700 900 60 75
1050 1250 220 1200 1500 250 1400 1750 300 1600 2000 340 1850 2500 390 2000 2750 430 2200 3000 460 2450 3250 510 2750 3500 570 2900 4000 610 3200 4500 680 3600 5000 760 4100 5500 850 4500 6000 940 900 1250 150
1000 90
1050 1250 113 1300 1500 135 1400 1750 150 1600 2000 169 1750 2250 184 1900 2500 203 2100 2750 221 2400 3000 244 2600 3500 274 2800 4000 304 3200 4250 334 3500 4500 368
Output voltage 4.16 kV 1150 1500 190 1300 1750 220 1550 2000 260 1750 2250 290 2000 2750 340 2200 3000 370 2500 3500 420 2750 3750 470 3000 4000 500 3300 4500 560 3600 5000 610 4000 5500 680 4500 6000 760 5000 6750 840 5500 7500 920
Special version -Z The order code Y15 (sine-wave filter) must be quoted in addition and requires plain text (see Description of options, page 5/20).
Siemens D 12 2006
2/9
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
kVA 2000 2200 2400 2700 2900 3200 2000 2300 2600 2900 3100 3500 3900 4200 4600 5100 5700 6300 6900 7400 8000 2000 2200 2500 2900 3200 3600 4000 4400 4900 5300 5800 6400 7100 7900 8600 9400
kW
hp
A 500 550 610 675 740 800 350 400 450 500 550 610 675 740 800 2 445 2 495 2 550 2 600 2 650 2 700 280 310 350 400 450 500 550 610 675 740 800 2 445 2 495 2 550 2 600
Fig. No. $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ & & & & & & $ $ $ $ $ $ $ $ $ $ $ & & & & & &
kVA 1800 2100 2400 2700 3000 3400 3700 4100 4500 4900 5500 6100 6700 7300 1900 2300 2600 3000 3300 3700 4100 4500 4900 5400 6100 6700 7300 8000
kW
hp
A 170 200 230 260 290 325 360 390 2 215 2 235 2 265 2 292 2 320 2 350 170 200 230 260 290 325 360 390 2 215 2 235 2 265 2 292 2 320 2 350
Fig. No. % % % % % % % % ( ( ( ( ( ( % % % % % % % % ( ( ( ( ( (
Output voltage 2.3 kV 1650 2250 1800 2500 2000 2750 2250 3000 2450 3250 2650 3500 1650 2250 1900 2500 2150 3000 2400 3250 2650 3500 2900 4000 3200 4250 3500 4500 3800 5000 4250 6000 4750 6500 5300 7000 5700 7500 6200 8000 6700 9000 1700 2250 1850 2500 2100 2750 2400 3000 2700 3500 3000 4000 3300 4500 3700 5000 4100 5500 4500 6000 4800 6500 5400 7000 6000 8000 6600 9000 7300 9500
Output voltage 6.0 kV 1450 2000 1750 2250 2000 2500 2250 3000 2500 3500 2800 3750 3100 4000 3400 4500 3700 5000 4100 5500 4600 6000 5100 6500 5600 7000 6100 8000 1600 2000 1900 2500 2200 3000 2500 3250 2800 3500 3100 4000 3400 4500 3700 5000 4100 5500 4500 6000 5100 6500 5600 7000 6100 8000 6700 9000
2/10
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
kVA 1500 1650 1800 2050 2200 2400 1550 1750 2000 2150 2350 2700 2950 3200 3500 3900 4350 4800 5250 5600 6050 1600 1750 1950 2250 2500 2800 3100 3450 3800 4100 4500 4950 5550 6150 6700 7350 7950
kW
kVA 1400 1650 1900 2150 2400 2700 3000 3250 3600 3900 4400 4850 5300 5800 1550 1850 2100 2400 2650 2950 3300 3550 3950 4300 4850 5350 5850 6400
kW
Output voltage 2.3 kV 1250 1500 380 1350 1750 410 1500 2000 450 1700 2250 510 1850 2500 550 2000 2750 600 1300 1750 270 1450 2000 310 1650 2250 350 1800 2500 380 1950 2750 410 2250 3000 470 2500 3250 520 2700 3500 560 2900 4000 610 3250 4500 680 3650 5000 760 4000 5500 840 4400 6000 920 4700 6250 980 5100 6500 1060 1300 1750 220 1450 2000 240 1600 2250 270 1850 2500 310 2100 2750 350 2350 3000 390 2600 3500 430 2900 4000 480 3200 4250 530 3450 4500 570 3800 5000 625 4200 5500 690 4600 6000 770 5100 7000 850 5600 7500 930 6200 8000 1020 6600 9000 1100
Output voltage 6.0 kV 1200 1500 136 1400 1750 160 1600 2000 184 1800 2250 208 2000 2500 232 2250 2750 260 2500 3000 288 2700 3500 312 3000 4000 344 3300 4500 376 3700 5000 424 4100 5500 468 4400 6000 512 4900 6500 560 1300 1750 136 1500 2000 160 1750 2250 184 2000 2750 208 2200 3000 232 2500 3250 260 2750 3500 288 3000 4000 312 3300 4500 344 3600 4750 376 4000 5000 424 4500 6000 468 4900 6500 512 5400 7000 560
Special version -Z The order code Y15 (sine-wave filter) must be quoted in addition and requires plain text (see Description of options, page 5/20).
Siemens D 12 2006
2/11
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Options
When ordering a converter with options, add -Z to the order number of the converter, followed by the order code(s) for the desired option(s). Example: 6SL3810-2LM32-5AA0-Z +N15+L60+...
Input-side options 24-pulse Basic Line Module Capacitor trip device 110 to 120 V DC 1) Capacitor trip device 230 V DC 1) Circuit-breaker at converter input 2) N15 N20 N21 N13 N15 N20 N21 N13
In the following tables, related options are arranged in groups. Whether the options can be combined or are mutually exclusive is indicated within these groups. A detailed description of the options can be found in the chapter Description of options.
1) Options N20 and N21 cannot be combined with option U01 (converter version for NAFTA with UL listing). 2) Option N13 is available on request in connection with option U01. Output-side options Output reactor Sine-wave filter (plain text required) Bidirectional synchronized bypass operation L08 Y15 L29 L08 Y15 L29
Protection functions Grounding switch at converter input 1) (motor-operated) Grounding switch at converter output 1) (motor-operated) EMERGENCY STOP category 1 Safety closing/interlocking system L48 L49 L60 M10
L48
L49
L60
M10
1) Options L48 and L49 are available on request in connection with option U01 (converter version for NAFTA with UL listing). Temperature detection and evaluation (standard: 3 PT100 inputs) 2 thermistor protection relays for alarm and fault 1) 2 x 2 thermistor protection relays for alarm and fault 1) 3 x 2 thermistor protection relays for alarm and fault 1) PT100 evaluation unit with 3 inputs 1) 2 PT100 evaluation units with 3 inputs each 1) PT100 evaluation unit with 6 inputs, 2 analog outputs (outputs for display connected to control) 1) PT100 evaluation unit with 6 inputs for explosion-proof motors, 2 analog outputs (outputs for display connected to control) 1) 2) L80 L81 L82 L90 L91 L93 L95 L80 L81 L82 L90 L91 L93 L95
1) Options L.. cannot be combined with option G61 (additional TM31 Terminal Module). 2) Option L95 cannot be combined with option U01 (converter version for NAFTA with UL listing). Options can be combined Options are mutually exclusive
2/12
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Options (continued)
Enhanced degree of protection for cabinet units in air-cooled version (standard: IP22) Dust protection IP42 degree of protection M11 M42 M11 M42
Enhanced degree of protection for cabinet units in water-cooled version (standard: IP43) IP54 degree of protection M54
Control of auxiliaries
N30
N31
N32
N33
N35
N36
N37
N38
The contractor is switched on with the ON command at the converter and switched off with the OFF command (example: external fan on the motor). The supply voltage for the auxiliary to be powered must be provided externally. Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 4 kW Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 7 kW Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 11 kW Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 15 kW N30 N31 N32 N33
The contractor is switched off with the ON command at the converter and switched on with the OFF command (example: heater). The supply voltage for the auxiliary to be powered must be provided externally. Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 1 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 2 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 3 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 4 kW Design of air cooling Redundant fan in power section Converter prepared for connection to an external exhaust air system, with internal cabinet fans M61 M64 N35 N36 N37 N38 M61 M64
Connection of power and signal cables (standard: connection of power cables from bottom, connection of signal cables directly to the terminals of the Terminal Modules) Connection of power cables to converter input from top Connection of power cables to converter output from top Customers terminal block with cage clamp terminals for signal cables up to 2.5 mm2 Customers terminal block with screw terminals for signal cables up to 2.5 mm2 Connection of auxiliary voltage and signal cables from top M13 M78 M32 M33 M34
M13
M78
M32
M33
M34
Control and display instruments in the door of the control cabinet Signal lamps and start/stop button in the cabinet door Display instruments in the cabinet door for voltage, current, speed and power also including signal lamps and start/stop button Display instruments in the cabinet door for current, speed, power and winding temperature also including signal lamps and start/stop button K20 K21
K20
K21
K22
K22
Siemens D 12 2006
2/13
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Options (continued)
Interface modules for connection to external bus systems (standard: PROFIBUS (slave)) CAN bus interface (CANopen, on request) Modbus Plus interface Modbus RTU slave interface DeviceNet interface PROFINET interface (on request) Teleservice connection (on request) G20 G21 G22 G23 G24 G25 G20 G21 G22 G23 G24 G25
Interface modules for additional customer connections and speed encoders Additional TM31 Terminal Module 1) Second additional TM31 Terminal Module 1) Additional TM15 Terminal Module SMC30 Sensor Module Cabinet-Mounted G61 G62 G63 K50
G61
G62
G63
K50
1) For exclusions of options G61 and G62, see Description of options. Additional analog inputs/outputs (isolated) Additional analog inputs (isolated) 1) Additional analog outputs (isolated) 1) E86 E87 E86 E87
1) Options E86 and E87 cannot be combined with option G62 (second additional TM31 Terminal Module). Industry-specific options NAMUR terminal block Marine version with type certificate B00 M66 B00 M66
Individual certification of the converters for use on ships (contains option M66) Marine version with individual certificate from Germanische Lloyd (GL) Marine version with individual certificate from Lloyds Register (LR) Marine version with individual certificate from Bureau Veritas (BV), requires option Y75 (other auxiliary voltage supply) Marine version with individual certificate from Det Norske Veritas (DNV) Marine version with individual certificate from the American Bureau of Shipping (ABS) Marine version with individual certificate from the Chinese Classification Society (CCS) E11 E21 E31 E51 E61 E71
E11
E21
E31
E51
E61
E71
2/14
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Options (continued)
Functional options Control for separately excited synchronous motors with slip-ring excitation 1) Control for separately excited synchronous motors with brushless reverse field excitation 1) Automatic restart E01 E02 L32 E01 E02 L32
1) Options E01 and E02 are available on request in connection with option U01 (converter version for NAFTA with UL listing). Documentation (standard: PDF format in English on CD-ROM) Documentation in German Circuit diagrams, terminal diagrams and dimension drawings in DXF format 1) One set of printed documentation (multiple orders possible) Documentation in Russian (on request) Documentation in Italian (on request) Documentation in French (on request) Documentation in Spanish Documentation in Chinese Documentation in Japanese (on request) Circuit diagrams with customer-specific description field (plain text required) 1) D00 D02 D15 D56 D72 D77 D78 D84 D92 Y10 D00 D02 D15 D56 D72 D77 D78 D84 D92 Y10
1) The equipment-specific documents (circuit diagrams etc.) are available only in English/German. Rating plate language (standard: English/German) Rating plate in English/French Rating plate in English/Spanish Rating plate in English/Italian Rating plate in English/Russian (on request) Rating plate in English/Japanese (on request) Rating plate in English/Chinese (on request) T58 T60 T80 T85 T90 T91 T58 T60 T80 T85 T90 T91
Auxiliary voltage supply Auxiliary voltage other than 400 V 3 AC (primary voltage and frequency must be indicated in plain text) Y75
Siemens D 12 2006
2/15
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Options (continued)
Version for NAFTA (SINAMICS GM150 in air-cooled IGBT version; 2.3 kV, 3.3 kV, 4.16 kV) Converter version for NAFTA with UL listing Following options are included as standard in option U01: Safety closing/interlocking system Dust protection Rating plate language English/French Following options cannot be combined with option U01: Capacitor trip devices PT100 evaluation unit with 6 inputs for explosion-proof motors, 2 analog outputs (outputs for display connected to control) N20 and N21 L95 M10 M11 T58 U01 U01
Following options are available in connection with option U01 on special request: Circuit-breakers at converter input Grounding switch Control for separately excited synchronous motors UPS for power supply of the control N13 L48 and L49 E01 and E02 L53
Converter acceptance tests in presence of customer Visual acceptance of converter Functional acceptance of converter with inductive load Acceptance of insulation test of the converter 1) Customer-specific converter acceptance tests (on request) 1) Option F77 can only be ordered in connection with option F73. Cooling unit (water-cooled converter, standard: cooling unit with one stainless steel plate-type heat exchanger) Cooling unit with redundant stainless steel plate-type heat exchangers Cooling unit with one titanium plate-type heat exchanger Cooling unit with redundant titanium plate-type heat exchangers Converter without cooling unit (plant scope) Raw-water connection from bottom Raw-water data deviates from technical data (on request) 1) W02 W11 W12 W14 W20 Y40 F03 F73 F77 F97
F03
F73
F77
F97
W02
W11
W12
W14
W20
Y40
1) Option Y40 includes a cooling system which is adapted to the raw-water data according to the customers specifications. Other options Cabinet lighting and service socket outlet in control section UPS for power supply of control 1) Anti-condensation heating for cabinet Special paint finish according to RAL .... (in a color other than RAL 7035; plain text required) L50 L53 L55 Y09 L50 L53 L55 Y09
1) Option L53 is available on request in connection with option U01 (converter version for NAFTA with UL listing). Options can be combined Options are mutually exclusive
2/16
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version
Technical data
General technical data Power components Line-side converter Standard - Smaller power ranges at 2.3 kV to 4.16 kV: 12-pulse diode rectifier (Basic Line Module) - 6.0 kV and 6.6 kV as well as higher power ranges at 2.3 kV to 4.16 kV: 24-pulse diode rectifier (Basic Line Module) - Smaller power ranges at 2.3 kV to 4.16 kV: 24-pulse diode rectifier (Basic Line Module) Inverter (Motor Module) Closed-loop vector control 2 (driving 2 directions of rotation) Optical conductor, isolating transformer 230 V 1 AC 10%, 50/60 Hz 3% and 400 V 3 AC 10%, 50/60 Hz 3% or another auxiliary voltage (option Y75) 1000 m above sea level: no derating > 1000 m to 4000 m above sea level: current derating required > 2000 m to 4000 m above sea level: additionally voltage derating required In accordance with to DIN EN 50178/VDE 0160 (IEC 62103): pollution degree 2 (without conductive pollution), condensation not permitted In accordance with to EN 60529/VDE 0470 T1 (IEC 60529): IP22 (air cooling), IP43 (water cooling) IP42 (air cooling), IP54 (water cooling) In accordance with to DIN EN 61140/VDE 0140 T1 (IEC 61140): 1 BGV A 3 In accordance with to DIN EN 61800-3/VDE 0160 T100 (IEC 61800-3): no RI suppression Indoor requirements/RAL 7035, light gray EN 61800-3/VDE 0160 T100 (IEC 61800-3) EN 61800-4/VDE 0160 T104 (IEC 61800-4) EN 61800-5-1/VDE 0160 T105 (IEC 61800-5-1) EN 60146-1-1/VDE 0558 T11 (IEC 60146-1-1) EN 50178/VDE 0160 T100 (IEC 62103) EN 60204-11/VDE 0113 T11 (IEC 60204-11) Diodes, 3.3 kV or 6.5 kV IGBTs
Option Motor-side converter Closed-loop control Drive quadrants Isolation of power section/ controller and closed-loop control Auxiliary current supply (for fans, coolant pumps, precharging the DC link capacitors, controller and closed-loop control) Installation altitude
Insulation Degree of protection Standard Option Protection class Shock protection Interference transmission Paint finish/color Compliance with standards Standards
EU directives Air cooling Water cooling Permitted coolant temperature (raw-water) Inlet Outlet
- 98/37/EC + amendments (machinery directive) - 89/336/EEC + amendments (electromagnetic compatibility) Air cooling enhanced with integrated fans Water-water cooling unit, internal circuit, deionized water
Rated data Output voltage Input voltage Tolerance of input voltage Line frequency Line factor fundamental mode 2.3 kV 2 x 1.2 kV 10% 50/60 Hz 3% > 0.96 3.3 kV 2 x 1.7 kV 10% 50/60 Hz 3% > 0.96 4.16 kV 2 x 2.2 kV 10% 50/60 Hz 3% > 0.96 6.0 kV 2 2 1.55 kV 10% 50/60 Hz 3% > 0.96 6.6 kV 2 2 1.7 kV 10% 50/60 Hz 3% > 0.96
Siemens D 12 2006
2/17
SINAMICS GM150
Medium-Voltage Converters
IGBT version
5%
5%
2%
5%
Storage Climatic ambient conditions Ambient temperature Relative air humidity +5 C to +45 C 5% to 95% (only slight condensation permitted; converter must be completely dry before commissioning) 1K3 in acc. with EN 60721-3-1 (IEC 60721-3-1) (formation of ice not permitted) 2 without conductive pollution in acc. with EN 50178/VDE 0160 (IEC 62103)
2K2 in acc. with EN 60721-3-2 (IEC 60721-3-2) 2 without conductive pollution in acc. with EN 50178/VDE 0160 (IEC 62103)
3K3 in acc. with EN 60721-3-3 (IEC 60721-3-3) 2 without conductive pollution in acc. with EN 50178/VDE 0160 (IEC 62103)
Mechanical ambient conditions Stationary vibration, sinusoidal Displacement Acceleration Other mechanical conditions in accordance with class (greater strength for marine version) Other ambient conditions Biological ambient conditions in accordance with class Chemically active substances in accordance with class Mechanically active substances in accordance with class 1B1 in acc. with EN 60721-3-1 (IEC 60721-3-1) 1C1 in acc. with EN 60721-3-1 (IEC 60721-3-1) 1S1 in acc. with EN 60721-3-1 (IEC 60721-3-1) 2B1 in acc. with EN 60721-3-2 (IEC 60721-3-2) 2C1 in acc. with EN 60721-3-2 (IEC 60721-3-2) 2S1 in acc. with EN 60721-3-2 (IEC 60721-3-2) 3B2 in acc. with EN 60721-3-3 (IEC 60721-3-3) (without harmful flora) 3C2 in acc. with EN 60721-3-3 (IEC 60721-3-3) (no occurrence of salt mist) 3S1 in acc. with EN 60721-3-3 (IEC 60721-3-3) (3S3 with water cooling and degree of protection IP54) 1.5 mm at 2 Hz to 9 Hz 5 m/s2 at 9 Hz to 200 Hz 1M2 in acc. with EN 60721-3-1 (IEC 60721-3-1) 3.5 mm at 2 Hz to 9 Hz 10 m/s2 at 9 Hz to 200 Hz 15 m/s2 at 200 Hz to 500 Hz 2M2 in acc. with EN 60721-3-2 (IEC 60721-3-2) 0.3 mm at 2 Hz to 9 Hz 1 m/s2 at 9 Hz to 200 Hz 3M1 in acc. with EN 60721-3-3 (IEC 60721-3-3)
Note: The values specified under storage and transport apply to unpacked converters.
2/18
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version
2
0.9 0.8 0.7 0.6 0 1000 2000 m 3000 4000 Installation altitude above sea level
G_D012_EN_00028
If the converters are operated at installation altitudes > 1000 m above sea level or under ambient or coolant temperatures > 40 C with air cooling or > 35 C with water cooling, derating factors kH and kT must be taken into account for the rated current (DIN 43671). Note: The following applies for water-cooled versions: When determining the current derating factor, it is essential to consider the ambient temperature as well as the air pressure of the raw-water in the inlet, as components such as the link busbars are also subject to air cooling. This requires the factors kH and kT to be determined from the diagrams for air cooling as well as for water cooling. The smaller of the two products (kH kT) must be used as the current derating factor.
G_D012_EN_00025
1.0
For the permitted continuous current I: I Irated kH kT I: permitted continuous current Irated: rated current Voltage derating At installation altitudes > 2000 m, a voltage derating is required in addition to a current derating (EN 60664-1/VDE 0110 (IEC 60664-1)). This depends on the air and creepage distances in the unit.
G_D012_EN_00029
1.00
Correction factor kT
0.95
0.90 5
0.9 0.8 0.7 0.6 0 1000 m 2000 3000 Installation altitude above sea level
1.00
Correction factor kT
4000
0.95
Derating factor kU
1.0
Correction factor k H
0.9 0.8 0.7 0.6 0 1000 m 2000 3000 Installation altitude above sea level
4000
Siemens D 12 2006
2/19
SINAMICS GM150
Medium-Voltage Converters
IGBT version
2/20
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
$
1750
$
1750
$
1750
$
1750
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/21
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
$
1750
$
1750
$
1800
$
1800
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/22
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP22 IP22 IP22 IP22 IP22 IP22
$
1900
$
1900
$
1900
$
1900
$
1900
$
1950
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/23
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
$
1950
$
1950
$
2000
$
2000
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/24
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP22 IP22 IP22 IP22 IP22 IP22
&
3500
&
3600
&
3600
&
3600
&
3700
&
3700
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/25
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP22 IP22 IP22 IP22 IP22 IP22
$
1900
$
1900
$
1900
$
1950
$
1950
$
1950
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/26
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
$
2000
$
2000
$
2000
$
2000
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/27
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP22 IP22 IP22 IP22 IP22 IP22
&
3600
&
3600
&
3600
&
3700
&
3700
&
3700
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/28
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
%
2300
%
2300
%
2300
%
2300
%
2350
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/29
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
%
2350
%
2350
%
2350
%
2350
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/30
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP22 IP22 IP22 IP22 IP22 IP22
(
3550
(
3550
(
3650
(
3650
(
3650
(
3650
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/31
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
%
2300
%
2300
%
2300
%
2300
%
2300
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/32
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
%
2350
%
2350
%
2350
%
2350
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/33
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP22 IP22 IP22 IP22 IP22 IP22
(
3550
(
3550
(
3550
(
3650
(
3650
(
3650
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/34
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
)
2800
)
2800
)
2800
)
2850
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/35
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
)
2850
)
2900
)
2950
)
2950
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/36
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
)
3050
)
3050
)
3100
)
3100
)
3100
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/37
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
)
3300
)
3300
)
3350
)
3400
)
3500
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/38
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP22 IP22 IP22 IP22 IP22 IP22
+
5900
+
6300
+
6300
+
6300
+
6500
+
6500
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/39
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
)
3300
)
3300
)
3300
)
3350
)
3350
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/40
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
)
3350
)
3400
)
3450
)
3450
)
3450
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/41
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP22 IP22 IP22 IP22 IP22 IP22
+
6400
+
6400
+
6400
+
6500
+
6600
+
6600
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/42
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
*
4350
*
4350
*
4350
*
4350
*
4400
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/43
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
*
4400
*
4400
*
4400
*
4600
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/44
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP22 IP22 IP22 IP22 IP22 IP22
,
7650
,
7650
,
7750
,
7750
,
7750
,
7750
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/45
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
*
4350
*
4350
*
4350
*
4350
*
4350
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/46
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
*
4400
*
4400
*
4400
*
4600
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/47
SINAMICS GM150
Medium-Voltage Converters
IGBT version Air cooling, with sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP22 IP22 IP22 IP22 IP22 IP22
,
7650
,
7650
,
7650
,
7750
,
7750
,
7750
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) Without cooling system. 3) Plus 20 A precharging current for 25 s. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/48
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
$
2600
$
2650
$
2650
$
2650
$
2700
$
2700
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/49
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
$
2750
$
2800
$
2800
$
2800
$
2850
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/50
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
$
2850
$
2850
$
2850
$
2850
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/51
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
&
4100
&
4200
&
4200
&
4200
&
4200
&
4200
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/52
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
$
2750
$
2800
$
2800
$
2800
$
2850
$
2850
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/53
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
$
2850
$
2850
$
2850
$
2850
$
2850
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/54
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
&
4200
&
4200
&
4200
&
4200
&
4200
&
4200
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/55
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
%
3050
%
3100
%
3100
%
3100
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/56
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
%
3150
%
3150
%
3150
%
3150
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/57
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
(
4100
(
4200
(
4200
(
4300
(
4300
(
4300
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/58
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
%
3050
%
3100
%
3100
%
3100
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/59
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
%
3100
%
3150
%
3150
%
3150
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/60
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, without sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
(
4200
(
4200
(
4200
(
4300
(
4300
(
4300
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/61
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
)
3750
)
3850
)
3850
)
3900
)
3950
)
3950
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/62
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
)
4000
)
4200
)
4200
)
4200
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/63
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
)
4300
)
4300
)
4400
)
4400
)
4400
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/64
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
+
6900
+
7000
+
7100
+
7100
+
7100
+
7300
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/65
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
)
4200
)
4250
)
4250
)
4250
)
4300
)
4300
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/66
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
)
4350
)
4350
)
4850
)
4850
)
4850
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/67
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
+
7100
+
7100
+
7200
+
7200
+
8200
+
8200
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/68
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
*
5150
*
5200
*
5200
*
5400
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/69
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
*
5450
*
5450
*
5450
*
5450
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/70
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
,
8300
,
8400
,
8400
,
8500
,
8900
,
8900
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/71
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
*
5150
*
5200
*
5200
*
5400
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/72
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
*
5400
*
5450
*
5450
*
5450
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
Siemens D 12 2006
2/73
SINAMICS GM150
Medium-Voltage Converters
IGBT version Water cooling, with sine-wave filter
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 240 2 240 2 240 2 240 2 240 2 240
2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM 2 500 MCM IP43 IP43 IP43 IP43 IP43 IP43
,
8400
,
8400
,
8800
,
8900
,
8900
,
8900
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 50. Both approximate values need to be adapted to the motor which is actually used.
2) 3) 4) 5)
Approx. 5% of the power loss is dissipated into the atmosphere. Without cooling system. Plus 20 A precharging current for 25 s. Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
2/74
Siemens D 12 2006
3
3/2 3/2 3/2 3/6 3/8 3/8 3/14 3/15 3/15 3/16 3/18 Overview Benefits Design Function Selection and ordering data Options Technical data General technical data Control properties Ambient conditions Installation conditions and derating data Converter-related technical data
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Overview
Benefits
7 7 7
3
7 7
Compact design and high flexibility in configuration ensures easy plant integration Easy operation and monitoring on the convenient operator panel Easy and reliable operation through integrated maintenance functions: the converter signals early and automatically if maintenance is required or components need to be exchanged High robustness and reliability due to the use of IGCT power semiconductors in the high power range and fuseless design combined with intelligent reaction to external disturbances Can be easily integrated into automation solutions due to PROFIBUS interface supplied as standard and various analog and digital interfaces High level of service-friendliness through innovative power section design with compact phase modules and easy access to all components
Design
SINAMICS GM150 converters in IGCT version are available in the basic circuit with a 12-pulse or 24-pulse Basic Line Module (option). For higher output ratings, two or three complete converter units with isolated DC links are operated in parallel. Phase modules in which IGCTs, diodes etc. are grouped together in one pressure stack are used in the Motor Modules. The converter consists of cabinet units for the Basic Line Module and for the Motor Module. One of three phase modules and the control section in the Motor Module cabinet are highlighted in the illustration.
The water-cooled SINAMICS GM150 converters in IGCT version with IGCT Motor Modules are an addition to the SINAMICS GM150 converters as IGBT version in the upper power range up to 28 MVA. SINAMICS GM150 converters in IGCT version are optimally matched to Siemens motors. SINAMICS GM150 converters in IGCT version offer economic drive solutions that can be matched to customers specific requirements by chosing from the wide range of available components and options. IGCT converters are available for the following voltage and power ranges:
Rated output voltage 3.3 kV Type rating 10 MVA to 28 MVA
Global use SINAMICS GM150 converters in IGCT version are manufactured to international standards and regulations, making them ideally suited for global use. These converters are also available in a marine version (meeting the requirements of all major classification organizations).
3/2
Siemens D 12 2006
G_D012_EN_00009
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Design (continued)
50/60 Hz 3 AC 2.3 kV to 36 kV
3
3
DC link capacitors
Motor
Block diagram
Siemens D 12 2006
3/3
G_D012_EN_00010
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Design (continued)
The following circuit designs are available for SINAMICS GM150 in IGCT version.
10
3
3 3 3
G_D012_XX_00011
24-pulse infeed through series connection of two Basic Line Modules: option N15
3/4
Siemens D 12 2006
G_D012_XX_00012
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Design (continued)
11 12
G_D012_XX_00014
Power increased by parallel operation of two converter units 1) 24-pulse infeed possible
Power increased by parallel operation of three converter units 1) 36-pulse infeed possible
3/5
G_D012_XX_00015
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Function
Characteristic features
SINAMICS GM150 in IGCT version Line Module (line-side rectifier) Basic Line Module, 12-pulse (two-quadrant operation) Basic Line Module, 24-pulse (two-quadrant operation) Motor Module (motor-side inverter) Voltage range Power range (typ.) Cooling method Water cooling Control modes Induction motor Synchronous motor, separately excited Synchronous motor, permanently excited Standard Option Option Standard 3.3 kV 10 MVA to 28 MVA Standard Option
Setpoint input
Ramp-function generator
Operating hours and switching cycle The operating hours of the fans are detected and logged so that preventive maintenance or replacements counter can be performed. The switching cycles of the circuit-breaker are detected and added up, to form the basis of preventive maintenance work. Detection of actual motor speed (option) Operator protection The SMC30 Sensor Module Cabinet-Mounted can be used to detect the actual motor speed. The signals from the rotary pulse encoder are converted here and made available for evaluation via the DRIVE-CLiQ interface of the controller. The cabinet doors of the power sections are fitted with electromagnetic locks. This prevents the cabinet doors from being opened while hazardous voltages are present inside the cabinet.
3/6
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Function (continued)
Software and protection functions
SINAMICS GM150 in IGCT version EMERGENCY STOP button Description The converters are equipped as standard with an EMERGENCY STOP button with protective collar which is fitted in the cabinet door. The contacts of the pushbutton are connected in parallel to the terminal block so they can be integrated in a protection concept on the plant side. EMERGENCY STOP category 0 is set as standard for an uncontrolled shutdown (DIN EN 60204-1/VDE 0113-1 (IEC 60204-1)). The function includes voltage disconnection of the converter output through the circuit-breaker. Consequently the motor coasts down. EMERGENCY STOP category 1 is optionally available for a controlled shutdown. The converters feature insulation monitoring of the whole galvanic network from the secondary side of the transformer to the stator windings of the motor. An extensive package of options for I/O monitoring (from the transformer and the motor through to the auxiliaries) is available. In addition it is possible to monitor the temperature with thermocouples or PT100 resistors. A warning message is issued first when the overtemperature threshold responds. If the temperature rises further, either a shutdown is carried out or automatic influencing of the output current so that a reduction in the thermal load is achieved. Following elimination of the cause of the fault (e.g. improvement of the ventilation), the original operating values are automatically resumed. In the case of water-cooled converters, the water temperature and flow rate are detected at several points in the cooling circuit and evaluated. An extensive self-diagnostics protects the converter and reports faults. If grounding on the line or motor side is required for safety and protection reasons, a motor-operated grounding switch can be ordered. For safety reasons, the converter controller locks these grounding switches against activation while voltage is still present. The control is integrated into the protection and monitoring chain of the converter. The grounding switches are inserted automatically when the standard grounding switches of the DC link are inserted.
AOP30 operator panel It has the following features and characteristics: graphical LCD display with backlighting for plain-text display and a bar display of process variables LEDs for displaying the operational status help function describing causes of and remedies for faults and alarms keypad for operational control of a drive local/remote switchover for selecting the input point (priority assigned to operator panel or customers terminal block/ PROFIBUS) numeric keypad for input of setpoint or parameter values function keys for prompted navigation in the menu two-stage safety strategy to protect against accidental or unauthorized changes to settings. Operation of the drive from the operator panel can be disabled by a password, ensuring that only parameter values and process variables can be displayed in the panel. A password can be used to prevent the unauthorized modification of converter parameters. The operator panel languages - English, German, Spanish and Chinese - are stored on the CompactFlash card of the Control Unit. The AOP30 operator panel is fitted into the cabinet door of the SINAMICS GM150 for operation, monitoring and commissioning.
Siemens D 12 2006
3/7
SINAMICS GM150
Medium-Voltage Converters
IGCT version
kVA
Options
When ordering a converter with options, add -Z to the order number of the converter, followed by the order code(s) for the desired option(s). Example: 6SL3835-2LN41-8AA0-Z +N15+L60+...
Input-side options 24-pulse Basic Line Module Circuit-breaker at converter input (on request) N15 N13 N15 N13
In the following tables, related options are arranged in groups. Whether the options can be combined or are mutually exclusive is indicated within these groups. A detailed description of the options can be found in the chapter Description of options.
Protection functions Grounding switch at converter input (motor-operated) Grounding switch at converter output (motor-operated) Disconnector at converter output EMERGENCY STOP category 1 Safety closing/interlocking system L48 L49 L51 L60 M10
L48
L49
L51
L60
M10
3/8
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Options (continued)
Temperature detection and evaluation (standard: 3 PT100 inputs) 2 thermistor protection relays for alarm and fault 1) 2 x 2 thermistor protection relays for alarm and fault 1) 3 x 2 thermistor protection relays for alarm and fault 1) PT100 evaluation unit with 3 inputs 1) 2 PT100 evaluation units with 3 inputs each 1) 3 PT100 evaluation units with 3 inputs each 1) PT100 evaluation unit with 6 inputs, 2 analog outputs (outputs for display connected to control) 1) 2 PT100 evaluation units each with 6 inputs and 2 analog outputs (outputs for display connected to control) 2) PT100 evaluation unit with 6 inputs for explosion-proof motors, 2 analog outputs (outputs for display connected to control) 1) 2 PT100 evaluation units each with 6 inputs for explosion-proof motors and 2 analog outputs (outputs for display connected to control) 2) L80 L81 L82 L90 L91 L92 L93 L94 L80 L81 L82 L90 L91 L92 L93 L94 L95 L96
L95
L96
1) Options L.. cannot be combined with option G61 (additional TM31 Terminal Module). 2) Options L94 and L96 cannot be combined with option G61 and G62 (additional TM31 Terminal Modules) and with option E86 (additional analog inputs). Control of auxiliaries N30 N31 N32 N33 N35 N36 N37 N38
The contractor is switched on with the ON command at the converter and switched off with the OFF command (example: external fan on the motor). The supply voltage for the auxiliary to be powered must be provided externally. Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 4 kW Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 7 kW Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 11 kW Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 15 kW N30 N31 N32 N33
The contractor is switched off with the ON command at the converter and switched on with the OFF command (example: heater). The supply voltage for the auxiliary to be powered must be provided externally. Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 1 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 2 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 3 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 4 kW N35 N36 N37 N38
Siemens D 12 2006
3/9
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Options (continued)
Connection of signal cables (standard: connection of signal cables directly to the terminals of the Terminal Modules) Customers terminal block with cage clamp terminals for signal cables up to 2.5 mm2 M32 M33 M32 M33
Customers terminal block with screw terminals for signal cables up to 2.5 mm2
Control and display instruments in the door of the control cabinet Signal lamps and start/stop button in the cabinet door Display instruments in the cabinet door for voltage, current, speed and power also including signal lamps and start/stop button Display instruments in the cabinet door for current, speed, power and winding temperature also including signal lamps and start/stop button K20 K21
K20
K21
K22
K22
Interface modules for connection to external bus systems (standard: PROFIBUS (slave)) CAN bus interface (CANopen, on request) Modbus Plus interface Modbus RTU slave interface DeviceNet interface PROFINET interface (on request) Teleservice connection (on request) G20 G21 G22 G23 G24 G25
G20
G21
G22
G23
G24
G25
Interface modules for additional customer connections and speed encoders Additional TM31 Terminal Module 1) Second additional TM31 Terminal Module 1) Additional TM15 Terminal Module SMC30 Sensor Module Cabinet-Mounted G61 G62 G63 K50
G61
G62
G63
K50
1) For exclusions of options G61 and G62, see Description of options. Options can be combined Options are mutually exclusive
3/10
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Options (continued)
Additional analog inputs/outputs (isolated) Additional analog inputs (isolated) 1) Additional analog outputs (isolated) 2) E86 E87 E86 E87
1) Option E86 cannot be combined with option G62 (second additional TM31 Terminal Module) and with options L94 and L96 (2 PT100 evaluation units). 2) Option E87 cannot be combined with option G62 (second additional TM31 Terminal Module). Diagnostics module PADU8 diagnostics module (8 analog and 8 digital signals) G66
Industry-specific options NAMUR terminal block Marine version with type certificate B00 M66
B00
M66
Individual certification of the converters for use on ships (on request, contains option M66) Marine version with individual certificate from Germanische Lloyd (GL) Marine version with individual certificate from Lloyds Register (LR) Marine version with individual certificate from Bureau Veritas (BV), requires option Y75 (other auxiliary voltage supply) Marine version with individual certificate from Det Norske Veritas (DNV) Marine version with individual certificate from the American Bureau of Shipping (ABS) Marine version with individual certificate from the Chinese Classification Society (CCS) E11 E21 E31 E51 E61 E71
E11
E21
E31
E51
E61
E71
Functional options Control for separately excited synchronous motors with slip-ring excitation Control for separately excited synchronous motors with brushless reverse field excitation Control for permanently excited synchronous motors Automatic restart E01 E02 E03 L32
E01
E02
E03
L32
Siemens D 12 2006
3/11
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Options (continued)
Documentation (standard: PDF format in English on CD-ROM) Documentation in German Circuit diagrams, terminal diagrams and dimension drawings in DXF format 1) One set of printed documentation (multiple orders possible) Documentation in Russian (on request) Documentation in Italian (on request) Documentation in French (on request) Documentation in Spanish Documentation in Chinese Documentation in Japanese (on request) Circuit diagrams with customer-specific description field (plain text required) 1) D00 D02 D15 D56 D72 D77 D78 D84 D92 Y10 D00 D02 D15 D56 D72 D77 D78 D84 D92 Y10
1) The equipment-specific documents (circuit diagrams etc.) are available only in English/German. Rating plate language (standard: English/German) Rating plate in English/French Rating plate in English/Spanish Rating plate in English/Italian Rating plate in English/Russian (on request) Rating plate in English/Japanese (on request) Rating plate in English/Chinese (on request) T58 T60 T80 T85 T90 T91 T58 T60 T80 T85 T90 T91
Auxiliary voltage supply Auxiliary voltage other than 400 V 3 AC (primary voltage and frequency must be indicated in plain text) Y75
3/12
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Options (continued)
Converter acceptance tests in presence of customer Visual acceptance of converter Functional acceptance of converter with inductive load Acceptance of insulation test of the converter 1) Customer-specific converter acceptance tests (on request) 1) Option F77 can only be ordered in connection with option F73. Cooling unit (standard: cooling unit with one stainless steel plate-type heat exchanger) Cooling unit with redundant stainless steel plate-type heat exchangers Cooling unit with one titanium plate-type heat exchanger Cooling unit with redundant titanium plate-type heat exchangers Converter without cooling unit (plant scope) Raw-water connection from bottom Raw-water data deviates from technical data (on request) 1) W02 W11 W12 W14 W20 Y40 W02 W11 W12 W14 W20 Y40 F03 F73 F77 F97 F03 F73 F77 F97
1) Option Y40 includes a cooling system which is adapted to the raw-water data according to the customers specifications. Other options Cabinet lighting and service socket outlet in control section UPS for power supply of control Anti-condensation heating for cabinet Special paint finish according to RAL .... (in a color other than RAL 7035; plain text required) L50 L53 L55 Y09 L50 L53 L55 Y09
Siemens D 12 2006
3/13
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Technical data
General technical data Power components Line-side converter Standard 12-pulse diode rectifier (Basic Line Module) 24-pulse diode rectifier (Basic Line Module) Inverter (Motor Module) Closed-loop vector control 2 (driving 2 directions of rotation) Optical conductor, isolating transformer Option Motor-side converter Closed-loop control Drive quadrants Isolation of power section/ controller and closed-loop control Diodes/IGCTs
Auxiliary current supply (for fans, 230 V 1 AC 10%, 50/60 Hz 3% and coolant pumps, precharging the DC 400 V 3 AC 10%, 50/60 Hz 3% link capacitors, controller and or another auxiliary voltage (option Y75) closed-loop control) Installation altitude 1000 m above sea level: no derating > 1000 m to 4000 m above sea level: current derating required > 2000 m to 4000 m above sea level: additionally voltage derating required In accordance with DIN EN 50178/VDE 0160 (IEC 62103): pollution degree 2 (without conductive pollution), condensation not permitted In accordance with EN 60529/VDE 0470 T1 (IEC 60529): IP43 In accordance with DIN EN 61140/VDE 0140 T1 (IEC 61140): 1 BGV A 3 In accordance with DIN EN 61800-3/VDE 0160 T100 (IEC 61800-3): no RI suppression Indoor requirements/RAL 7035, light gray EN 61800-3/VDE 0160 T100 (IEC 61800-3) EN 61800-4/VDE 0160 T104 (IEC 61800-4) EN 60146-1-1/VDE 0558 T11 (IEC 60146-1-1) EN 50178/VDE 0160 T100 (IEC 62103) EN 60204-11/VDE 0113 T11 (IEC 60204-11)
Insulation Degree of protection Protection class Shock protection Interference transmission Paint finish/color Compliance with standards Standards
- 98/37/EC + amendments (machinery directive) - 89/336/EEC + amendments (electromagnetic compatibility) Water-water cooling unit, internal circuit, deionized water
Rated data Output voltage Input voltage Tolerance of input voltage Line frequency Line factor fundamental mode 3.3 kV 2 x 1.7 kV 10% 50/60 Hz 3% > 0.96
3/14
Siemens D 12 2006
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Storage Climatic ambient conditions Ambient temperature Relative air humidity 25 C to +70 C 5% to 95% (only slight condensation permitted; converter must be completely dry before commissioning) 1K3 in acc. with EN 60721-3-1 (IEC 60721-3-1) (formation of ice not permitted) 2 without conductive pollution in acc. with EN 50178/VDE 0160 (IEC 62103)
2K2 in acc. with EN 60721-3-2 (IEC 60721-3-2) 2 without conductive pollution in acc. with EN 50178/VDE 0160 (IEC 62103)
3K3 in acc. with EN 60721-3-3 (IEC 60721-3-3) 2 without conductive pollution in acc. with EN 50178/VDE 0160 (IEC 62103)
Mechanical ambient conditions Stationary vibration, sinusoidal Displacement Acceleration Other mechanical conditions in accordance with class (greater strength for marine version) Other ambient conditions Biological ambient conditions in accordance with class Chemically active substances in accordance with class Mechanically active substances in accordance with class 1B1 in acc. with EN 60721-3-1 (IEC 60721-3-1) 1C1 in acc. with EN 60721-3-1 (IEC 60721-3-1) 1S1 in acc. with EN 60721-3-1 (IEC 60721-3-1) 2B1 in acc. with EN 60721-3-2 (IEC 60721-3-2) 2C1 in acc. with EN 60721-3-2 (IEC 60721-3-2) 2S1 in acc. with EN 60721-3-2 (IEC 60721-3-2) 3B2 in acc. with EN 60721-3-3 (IEC 60721-3-3) (without harmful flora) 3C2 in acc. with EN 60721-3-3 (IEC 60721-3-3) (no occurrence of salt mist) 3S1 in acc. with EN 60721-3-3 (IEC 60721-3-3) 1.5 mm at 2 Hz to 9 Hz 5 m/s2 at 9 Hz to 200 Hz 1M2 in acc. with EN 60721-3-1 (IEC 60721-3-1) 3.5 mm at 2 Hz to 9 Hz 10 m/s2 at 9 Hz to 200 Hz 15 m/s2 at 200 Hz to 500 Hz 2M2 in acc. with EN 60721-3-2 (IEC 60721-3-2) 0.3 mm at 2 Hz to 9 Hz 1 m/s2 at 9 Hz to 200 Hz 3M1 in acc. with EN 60721-3-3 (IEC 60721-3-3)
Note: The values specified under storage and transport apply to unpacked converters.
Siemens D 12 2006
3/15
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Correction factor kH
For the permitted continuous current I: I Irated kH kT I: permitted continuous current Irated: rated current Voltage derating At installation altitudes > 2000 m, a voltage derating is required in addition to a current derating in accordance with DIN VDE 0110/IEC 664-1 (EN 60664-1/VDE 0110 (IEC 60664-1)). This depends on the air and creepage distances in the unit.
G_D012_EN_00029
1.00
Correction factor kT
0.95
0.90 5
1.0 10 20
Correction factor k U
30 40 C 45 Coolant temperature
0.9 0.8 0.7 0.6 0 1000 m 2000 3000 Installation altitude above sea level
1.00
Correction factor kT
4000
0.95
Derating factor kU
1.0
Correction factor k H
0.9 0.8 0.7 0.6 0 1000 m 2000 3000 Installation altitude above sea level
4000
3/16
Siemens D 12 2006
G_D012_EN_00028
1.0
SINAMICS GM150
Medium-Voltage Converters
IGCT version
Siemens D 12 2006
3/17
SINAMICS GM150
Medium-Voltage Converters
IGCT version
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with induction motors and for a typical value of the cos phi power factor and efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 1000. Both approximate values need to be adapted to the motor which is actually used.
2) Approx. 5% of the power loss is dissipated into the atmosphere. 3) Without cooling system. 4) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
3/18
Siemens D 12 2006
SINAMICS SM150
4
4/2 4/2 4/2 4/6 4/8 4/8 4/14 4/15 4/15 4/16 4/18 Overview Benefits Design Function Selection and ordering data Options Technical data General technical data Control properties Ambient conditions Installation conditions and derating data Converter-related technical data
Siemens D 12 2006
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Overview
Design
Active Line Modules and Motor Modules share an almost identical structure with both the single-motor and the multi-motor drive. Phase modules in which IGCTs, diodes etc. are grouped together in one compact system are used in both. Single-motor drive With a single-motor drive, one Active Line Module and one Motor Module are connected back-to-back in the basic circuit via a DC link. For higher output ratings, two or three complete converter units with isolated DC links are operated in parallel.
4
SINAMICS SM150
Multi-motor drive With multi-motor drives, up to four power sections are operated on the common DC bus. In addition to the Active Line Module, three Motor Modules with three motors can be operated on the common DC bus with utilization of the direct exchange of energy. The converter consists of cabinet units for the Active Line Module and for the Motor Module. One of three phase modules and the control section in the Motor Module cabinet are highlighted in the illustration.
Water-cooled regenerative SINAMICS SM150 converters are available as single or multi-motor drives with the standard medium voltage IGCT power semiconductors. With multi-motor drives, a common DC bus enables the direct exchange of energy in generator and motor applications. IGCT converters are available for the following voltage and power ranges:
Rated output voltage 3.3 kV Max. continuous power Power (without overload (175% overload capability) capability) 10 MVA to 28 MVA 5 MVA to 17 MVA
The rated output in the concrete application will depend on the necessary load cycle. The transient maximum outputs are 10.5 MVA, 20 MVA and 30 MVA. Global use SINAMICS SM150 converters are manufactured to international standards and regulations, making them ideally suited for global use. These converters are also available in a marine version (meeting the requirements of all major classification organizations).
G_D012_EN_00016
Benefits
7 7 7
Compact design and high flexibility in configuration ensures easy plant integration Easy operation and monitoring on the convenient operator panel Easy and reliable operation through integrated maintenance functions: the converter signals early and automatically if maintenance is required or components need to be exchanged High robustness and reliability due to the use of IGCT power semiconductors in the high power range and fuseless design combined with intelligent reaction to external disturbances Can be easily integrated into automation solutions due to PROFIBUS interface supplied as standard and various analog and digital interfaces High level of service-friendliness through innovative power section design with compact phase modules and easy access to all components Assists system cost effectiveness by enabling reactive power to be made available to other drives given suitable configuration
4/2
Siemens D 12 2006
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Design (continued)
50/60 Hz 3 AC 2.3 kV to 36 kV
4
3
DC link capacitors
Motor
Block diagram
Siemens D 12 2006
4/3
G_D012_EN_00017
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Design (continued)
The following circuit designs are available for SINAMICS SM150.
13
14
4
G_D012_XX_00018 G_D012_XX_00019
Basic circuit
Power increased by parallel connection of two converter units (additionally reduction of line harmonic distortions) 1)
15
Power increased by parallel connection of three converter units (additionally reduction of line harmonic distortions) 1)
4/4
Siemens D 12 2006
G_D012_XX_00020
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Design (continued)
16 17
4
G_D012_XX_00021
On the DC bus configurations with two or three motors, energy can be exchanged through the common DC link with alternate operation as a motor and generator. This results in savings in the Active Line Module, the transformers and the circuit-breakers. These configurations are used mainly for single-stand cold rolling mills with a coiler and for transmission test stands.
Siemens D 12 2006
4/5
G_D012_XX_00022
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Function
Characteristic features
SINAMICS SM150 Line Module (line-side rectifier) Active Line Module (four-quadrant operation) Motor Module (motor-side inverter) Voltage range Power range (typ.) Cooling method Water cooling Control modes Induction motor Synchronous motor, separately excited Synchronous motor, permanently excited DC bus configuration with several Motor Modules on one common DC bus Standard Option Option Standard 3.3 kV 5 MVA to 28 MVA Standard Standard
Setpoint input
Ramp-function generator
Operating hours and switching cycle The operating hours of the fans are detected and logged so that preventive maintenance or replacements counter can be performed. The switching cycles of the circuit-breaker are detected and addedup, to form the basis of preventive maintenance work. Operator protection The cabinet doors of the power sections are fitted with electromagnetic locks. This prevents the cabinet doors from being opened while hazardous voltages are present inside the cabinet.
4/6
Siemens D 12 2006
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Function (continued)
Software and protection functions
SINAMICS SM150 EMERGENCY STOP button Description The converters are equipped as standard with an EMERGENCY STOP button with protective collar which is fitted in the cabinet door. The contacts of the pushbutton are connected in parallel to the terminal block so they can be integrated in a protection concept on the plant side. EMERGENCY STOP category 0 is set as standard for an uncontrolled shutdown (DIN EN 60204-1/VDE 0113-1 (IEC 60204-1)). The function includes voltage disconnection of the converter output through the circuit-breaker. Consequently the motor coasts down. EMERGENCY STOP category 1 is optionally available for a controlled shutdown. The converters feature insulation monitoring of the whole galvanic network from the secondary side of the transformer to the stator windings of the motor. An extensive package of options for I/O monitoring (from the transformer and the motor through to the auxiliaries) is available. In addition it is possible to monitor the temperature with thermocouples or PT100 resistors. A warning message is issued first when the overtemperature threshold responds. If the temperature rises further, either a shutdown is carried out or automatic influencing of the output current so that a reduction in the thermal load is achieved. Following elimination of the cause of the fault (e.g. improvement of ventilation), the original operating values are automatically resumed. In the case of water-cooled converters, the water temperature and flow rate are detected at several points in the cooling circuit and evaluated. An extensive self-diagnostics protects the converter and reports faults. If grounding on the line or motor side is required for safety and protection reasons, a motor operated grounding switch can be ordered. For safety reasons, the converter controller locks these grounding switches against activation while voltage is still present. The control is integrated into the protection and monitoring chain of the converter. The grounding switches are inserted automatically when the standard grounding switches of the DC link are inserted.
SIMATIC OP 177B operator panel The SIMATIC OP 177B operator panel is fitted into the cabinet door of the SINAMICS SM150 for operation, monitoring and commissioning. It has the following features and characteristics: 5.7" STN touch display Context-dependent operations by touch, permanently available functions can be selected using individual keys Non-volatile message buffer, no battery English and German are available as operator panel languages.
Siemens D 12 2006
4/7
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Options
When ordering a converter with options, add -Z to the order number of the converter, followed by the order code(s) for the desired option(s). Example: 6SL3845-7NN41-8AA0-Z +L08+L60+...
Output-side options Output reactor L08
In the following tables, related options are arranged in groups. Whether the options can be combined or are mutually exclusive is indicated within these groups. A detailed description of the options can be found in the chapter Description of options.
Protection functions Grounding switch at converter input (motor-operated) Grounding switch at converter output (motor-operated) Disconnector at converter output EMERGENCY STOP category 1 Safety closing/interlocking system L48 L49 L51 L60 M10
L48
L49
L51
L60
M10
1) Configuration with two motors which operate on a common DC link. With alternate operation as a motor and generator, energy is exchanged through the common DC link. Differences in the energy balance are equalized through the infeed (Active Infeed).
2) Configuration with three motors which operate on a common DC link. With alternate operation as a motor and generator, energy is exchanged through the common DC link. Differences in the energy balance are equalized through the infeed (Active Infeed).
4/8
Siemens D 12 2006
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Options (continued)
Temperature detection and evaluation (standard: 3 PT100 inputs) 2 thermistor protection relays for alarm and fault 1) 2 x 2 thermistor protection relays for alarm and fault 1) 3 x 2 thermistor protection relays for alarm and fault 1) PT100 evaluation unit with 3 inputs 1) 2 PT100 evaluation units with 3 inputs each 1) 3 PT100 evaluation units with 3 inputs each 1) PT100 evaluation unit with 6 inputs, 2 analog outputs (outputs for display connected to control) 1) 2 PT100 evaluation units each with 6 inputs and 2 analog outputs (outputs for display connected to control) 2) PT100 evaluation unit with 6 inputs for explosion-proof motors, 2 analog outputs (outputs for display connected to control) 1) 2 PT100 evaluation units each with 6 inputs for explosion-proof motors and 2 analog outputs (outputs for display connected to control) 2) L80 L81 L82 L90 L91 L92 L93 L94 L80 L81 L82 L90 L91 L92 L93 L94 L95 L96
L95
L96
1) Options L.. cannot be combined with option G61 (additional TM31 Terminal Module). 2) Options L94 and L96 cannot be combined with option G61 and G62 (additional TM31 Terminal Modules) and with option E86 (additional analog inputs). Control of auxiliaries N30 N31 N32 N33 N35 N36 N37 N38
The contractor is switched on with the ON command at the converter and switched off with the OFF command (example: external fan on the motor). The supply voltage for the auxiliary to be powered must be provided externally. Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 4 kW Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 7 kW Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 11 kW Controlled outgoing feeder for auxiliaries 400 V 3 AC, max. 15 kW N30 N31 N32 N33
The contractor is switched off with the ON command at the converter and switched on with the OFF command (example: heater). The supply voltage for the auxiliary to be powered must be provided externally. Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 1 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 2 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 3 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC, max. 4 kW N35 N36 N37 N38
Siemens D 12 2006
4/9
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Options (continued)
Connection of signal cables (standard: connection of signal cables directly to the terminals of the Terminal Modules) Customers terminal block with cage clamp terminals for signal cables up to 2.5 mm2 Customers terminal block with screw terminals for signal cables up to 2.5 mm2 M32 M33 M32 M33
Control and display instruments in the door of the control cabinet Signal lamps and start/stop button in the cabinet door K20 K21
K20
K21
K22
Display instruments in the cabinet door for voltage, current, speed and power also including signal lamps and start/stop button Display instruments in the cabinet door for current, speed, power and winding temperature also including signal lamps and start/stop button
K22
Interface modules for additional customer connections Additional TM31 Terminal Module 1) Second additional TM31 Terminal Module 1) Additional TM15 Terminal Module G61 G62 G63
G61
G62
G63
1) For exclusions of options G61 and G62, see Description of options. Additional analog inputs/outputs (isolated) Additional analog inputs (isolated) 1) Additional analog outputs (isolated) 2) E86 E87 E86 E87
1) Option E86 cannot be combined with option G62 (second additional TM31 Terminal Module) and with options L94 and L96 (2 PT100 evaluation units). 2) Option E87 cannot be combined with option G62 (second additional TM31 Terminal Module). Other interface modules PADU8 diagnostics module (8 analog and 8 digital signals) Pulse distributor for forwarding the speed encoder signal Optical bus terminal (OBT) for PROFIBUS G66 G70 G71 G66 G70 G71
4/10
Siemens D 12 2006
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Options (continued)
Industry-specific options NAMUR terminal block B00
Functional options Control for separately excited synchronous motors with slip-ring excitation Control for separately excited synchronous motors with brushless reverse field excitation Control for permanently excited synchronous motors Automatic restart E01 E02 E03 L32
E01
E02
E03
L32
4
D72 D77 D78 D84 D92 Y10
Documentation (standard: PDF format in English on CD-ROM) Documentation in German Circuit diagrams, terminal diagrams and dimension drawings in DXF format 1) One set of printed documentation (multiple orders possible) Documentation in Russian (on request) Documentation in Italian (on request) Documentation in French (on request) Documentation in Spanish Documentation in Chinese Documentation in Japanese (on request) Circuit diagrams with customer-specific description field (plain text required) 1) D00 D02 D15 D56 D72 D77 D78 D84 D92 Y10
D00
D02
D15
D56
1) The equipment-specific documents (circuit diagrams etc.) are available only in English/German. Options can be combined Options are mutually exclusive
Siemens D 12 2006
4/11
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Options (continued)
Rating plate language (standard: English/German) Rating plate in English/French Rating plate in English/Spanish Rating plate in English/Italian Rating plate in English/Russian (on request) Rating plate in English/Japanese (on request) T58 T60 T80 T85 T90 T91 T58 T60 T80 T85 T90 T91
Converter acceptance tests in presence of customer Visual acceptance of converter Functional acceptance of converter with inductive load Acceptance of insulation test of the converter 1) Customer-specific converter acceptance tests (on request) 1) Option F77 can only be ordered in connection with option F73. Cooling unit (standard: cooling unit with one stainless steel plate-type heat exchanger) Cooling unit with redundant stainless steel plate-type heat exchangers Cooling unit with one titanium plate-type heat exchanger Cooling unit with redundant titanium plate-type heat exchangers Converter without cooling unit (plant scope) Raw-water data deviates from technical data (on request) 1) W02 W11 W12 W14 Y40 F03 F73 F77 F97
F03
F73
F77
F97
W02
W11
W12
W14
Y40
1) Option Y40 includes a cooling system which is adapted to the raw-water data according to the customers specifications. Options can be combined Options are mutually exclusive
4/12
Siemens D 12 2006
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Options (continued)
Other options Cabinet lighting and service socket outlet in control section Anti-condensation heating for cabinet Special paint finish according to RAL .... (in a color other than RAL 7035; plain text required) L50 L55 Y09 L50 L55 Y09
Siemens D 12 2006
4/13
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Technical data
General technical data Power components Line-side converter Motor-side converter Closed-loop control Drive quadrants Isolation of power section/ controller and closed-loop control IGCTs Regulated, self-commutating feed/feedback unit (Active Line Module) Inverter (Motor Module) Closed-loop vector control 4 (driving and braking, 2 directions of rotation each) Optical conductor, isolation transformer
Auxiliary current supply (for fans, 230 V 1 AC 10%, 50/60 Hz 3% and coolant pumps, precharging the DC 400 V 3 AC 10%, 50/60 Hz 3% link capacitors, controller and closed-loop control) Installation altitude 1000 m above sea level: no derating > 1000 m to 4000 m above sea level: current derating required > 2000 m to 4000 m above sea level: additionally voltage derating required In accordance with DIN EN 50178/VDE 0160 (IEC 62103): pollution degree 2 (without conductive pollution), condensation not permitted In accordance with EN 60529/VDE 0470 T1 (IEC 60529): IP43 In accordance with DIN EN 61140/VDE 0140 T1 (IEC 61140): 1 BGV A 3 In accordance with DIN EN 61800-3/VDE 0160 T100 (IEC 61800-3): no RI suppression Indoor requirements/RAL 7035, light gray EN 61800-3/VDE 0160 T100 (IEC 61800-3) EN 61800-4/VDE 0160 T104 (IEC 61800-4) EN 60146-1-1/VDE 0558 T11 (IEC 60146-1-1) EN 50178/VDE 0160 T100 (IEC 62103) EN 60204-11/VDE 0113 T11 (IEC 60204-11)
Insulation Degree of protection Protection class Shock protection Interference transmission Paint finish/color Compliance with standards Standards
- 98/37/EC + amendments (machinery directive) - 89/336/EEC + amendments (electromagnetic compatibility) Water-water cooling unit, internal circuit, deionized water
Rated data Output voltage Input voltage Tolerance of input voltage Line frequency Line factor fundamental mode 3.3 kV 3.3 kV 10% 50/60 Hz 3% 1
4/14
Siemens D 12 2006
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Storage Climatic ambient conditions Ambient temperature Relative air humidity 25 C to +70 C 5% to 95% (only slight condensation permitted; converter must be completely dry before commissioning) 1K3 in acc. with EN 60721-3-1 (IEC 60721-3-1) (formation of ice not permitted) 2 without conductive pollution in acc. with EN 50178/VDE 0160 (IEC 62103)
2K2 in acc. with EN 60721-3-2 (IEC 60721-3-2) 2 without conductive pollution in acc. with EN 50178/VDE 0160 (IEC 62103)
3K3 in acc. with EN 60721-3-3 (IEC 60721-3-3) 2 without conductive pollution in acc. with EN 50178/VDE 0160 (IEC 62103)
Mechanical ambient conditions Stationary vibration, sinusoidal Displacement Acceleration Other mechanical conditions in accordance with class (greater strength for marine version) Other ambient conditions Biological ambient conditions in accordance with class Chemically active substances in accordance with class Mechanically active substances in accordance with class 1B1 in acc. with EN 60721-3-1 (IEC 60721-3-1) 1C1 in acc. with EN 60721-3-1 (IEC 60721-3-1) 1S1 in acc. with EN 60721-3-1 (IEC 60721-3-1) 2B1 in acc. with EN 60721-3-2 (IEC 60721-3-2) 2C1 in acc. with EN 60721-3-2 (IEC 60721-3-2) 2S1 in acc. with EN 60721-3-2 (IEC 60721-3-2) 3B2 in acc. with EN 60721-3-3 (IEC 60721-3-3) (without harmful flora) 3C2 in acc. with EN 60721-3-3 (IEC 60721-3-3) (no occurrence of salt mist) 3S1 in acc. with EN 60721-3-3 (IEC 60721-3-3) 1.5 mm at 2 Hz to 9 Hz 5 m/s2 at 9 Hz to 200 Hz 1M2 in acc. with EN 60721-3-1 (IEC 60721-3-1) 3.5 mm at 2 Hz to 9 Hz 10 m/s2 at 9 Hz to 200 Hz 15 m/s2 at 200 Hz to 500 Hz 2M2 in acc. with EN 60721-3-2 (IEC 60721-3-2) 0.3 mm at 2 Hz to 9 Hz 1 m/s2 at 9 Hz to 200 Hz 3M1 in acc. with EN 60721-3-3 (IEC 60721-3-3)
Note: The values specified under storage and transport apply to unpacked converters.
Siemens D 12 2006
4/15
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Correction factor kH
For the permitted continuous current I: I Irated kH kT I: permitted continuous current Irated: rated current Voltage derating At installation altitudes > 2000 m, a voltage derating is required in addition to a current derating (EN 60664-1/VDE 0110 (IEC 60664-1)). This depends on the air and creepage distances in the unit.
G_D012_EN_00029
1.00
Correction factor kT
0.95
1.0
Correction factor k U
0.90 5
10
20
30 40 C 45 Coolant temperature
0.9 0.8 0.7 0.6 0 1000 m 2000 3000 Installation altitude above sea level
1.00
Correction factor kT
4000
0.95
Derating factor kU
1.0
Correction factor k H
0.9 0.8 0.7 0.6 0 1000 m 2000 3000 Installation altitude above sea level
4000
4/16
Siemens D 12 2006
G_D012_EN_00028
1.0
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
Siemens D 12 2006
4/17
SINAMICS SM150
Medium-Voltage Converters
SINAMICS SM150
1) The figures for the rated input current and the power figures in hp and kW are approximate values which were determined for operation with synchronous motors, for the power factor cos phi = 1 and taking into account the efficiency of the motor. The hp figures are based on the NEC and CEC directives for the North American market. The kW values are quoted in steps which can be divided by 1000. Both approximate values need to be adapted to the motor which is actually used. 2) The underlying circuit design is based on a drive group in which the drives operate both as motor and generator (see circuit design). Energy is exchanged via the DC link. The specified power corresponds to the infeed power.
3) Approx. 5% of the power loss is dissipated into the atmosphere. 4) Without cooling system. 5) Figures refer to a subsystem; please refer to Circuit designs for the number of subsystems to be connected on the line and motor side.
4/18
Siemens D 12 2006
Description of options
5
Order codes for options B00 D00 to D92 E01 to E03 E11 to E87 F03 to F97 G20 to G62 G63 to G71 K20 to K50 L08 and L21 L29 and L32 L48 to L51 L53 to L60 L80 to L87 L90 to L92 L93 and L94 L95 and L96 M10 to M34 M42 to M78 N13 to N22 N30 to N38 T58 to T91 U01 W02 to W20 Y09 to Y75
5/2 5/3 5/4 5/5 5/6 5/7 5/8 5/9 5/10 5/11 5/12 5/13 5/14 5/15 5/16 5/17 5/18 5/19
5/20
Siemens D 12 2006
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options
To enable the required description to be found more easily, the following descriptions of options are sorted alphabetically by order codes. If an option is only available for certain converter configurations, this is indicated in brackets after the option title. Note: An option can only be ordered once per converter, if not explicitly quoted. Assignment of the NAMUR terminal block
Terminal No. Type Preassignment Comment For signal lines that must meet Protective extra-low voltage PELV requirements =.LCX2 1 1.0 1.1 3 3.0 3.1 10 11 12 13 14 15 16 M Reference con ductor of 24 V DC supply 24 V DC supply Protected with internal 2 A fuse Corresponds to OFF3
P24
B00 NAMUR terminal block The terminal block has been configured in accordance with the requirements and guidelines of the Standards Working Group for Instrumentation and Control in the Chemical Industry (NAMUR Recommendation NE37), i.e. fixed terminals are assigned to certain functions of the devices. The inputs and outputs assigned to the terminals comply with Protective extra-low voltage PELV requirements.
DI DI DI DI DI DI DI
For temperature monitoring of explosion-proof motors, options for PTC thermistors with PTB approval and PT100 evaluation units for use in areas at risk of explosion can be obtained. This terminal block and the associated functions are reduced to the required amount. In comparison to the NAMUR recommendation, optional terminals are not listed.
Counterclockwise 0 signal for CW phase sequence 1 signal for CCW phase sequence Line disconnection Ready to run Motor rotates EMERGENCY STOP sequence Relay output (NO contact) Relay output (NO contact) Relay output (changeover contact) Motor current is default setting; can be reparameterized for other variables If the limit value is exceeded, a disconnection follows
17 18 30 31
Circuit-breaker
Fault
Converter transformer
Speed setpoint
Auxiliary supply 400 V 3 AC =.EA-Q11:1 =.EA-Q11:3 =.EA-Q11:5 Auxiliary supply 230 V 1 AC =.EB-X1:1 =.EB-X1:2 Power supply of auxiliaries 400 V 3 AC (e.g. external fan) =.GC-X1:1 =.GC-X1:2 =.GC-X1:3 =.GC-X1:4 =.GC-X1:5 =.GC-X1:6 Power supply of auxiliaries 230 V 1 AC (e.g. anti-condensation heating of the motor) =.GC-X1:7 =.GC-X1:8 =.GC-X1:9 =.GC-X1:10 Motor connection
60 61 62 63
AC
For connecting the PTC sensor of the motor
DC
A1X3
90/91 AI
If PT100 resistance thermometers are fitted in the windings of the motor in order to protect the motor, PT100 evaluation units for explosion-proof motors are available with options L95 and L96.
G_D012_EN_00023
DC AC
1U2, 1V2, 1W2
If a forced-ventilated machine is used due to the application (load torque/control range), controlled outgoing feeders fused with motor circuit-breakers are available with options N30 to N33 to enable supply to an external fan. The incoming voltage supply for the external fan must be provided on the plant side. Options N35 to N38 also offer a controlled and fused external voltage outgoing feeder for the anti-condensation heating in the motor.
5/2
Siemens D 12 2006
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
D00 to D92 Documentation The standard documentation is supplied in English on CD-ROM. The circuit diagrams/terminal diagrams are available only in English/German.
Option Description D00 Documentation in German With order code D00 the documentation is supplied in German on CD-ROM. Circuit diagrams, terminal diagrams and dimension drawings in DXF format Documents such as circuit diagrams, terminal diagrams, the arrangement diagram and the dimension drawing can be ordered with order code D02 in DXF format, e.g. for use in AutoCAD systems. One set of printed documentation (multiple orders possible) If documentation is also required on paper, this must be ordered using order code D15. Documentation in Russian (on request) With order code D56 the documentation is supplied in Russian on CD-ROM. Documentation in Italian (on request) With order code D72 the documentation is supplied in Italian on CD-ROM. Documentation in French (on request) With order code D77 the documentation is supplied in French on CD-ROM. Documentation in Spanish With order code D78 the documentation is supplied in Spanish on CD-ROM. Documentation in Chinese With order code D84 the documentation is supplied in Chinese on CD-ROM. Documentation in Japanese (on request) With order code D92 the documentation is supplied in Japanese on CD-ROM.
E01 Control for separately excited synchronous motors with slip-ring excitation (for static excitation units see Accessories) If the converter is to be used to control separately excited synchronous motors with slip-ring excitation, E01 must be included in the order. For slip-ring excitation, the exciter cabinet with its own order number must be ordered additionally. Note: The converter and exciter cabinet must be ordered together. Option E01 is available on request in connection with option U01 (converter version for NAFTA with UL listing). E02 Control for separately excited synchronous motors with brushless reverse field excitation (for static excitation units see Accessories) If the converter is to be used to control separately excited synchronous motors with brushless reverse field excitation, E02 must be included in the order. For brushless reverse field excitation, the exciter cabinet with its own order number must be ordered additionally. Note: The converter and exciter cabinet must be ordered together. Option E02 is available on request in connection with option U01 (converter version for NAFTA with UL listing). E03 Control for permanently excited synchronous motors (SINAMICS GM150 in IGCT version and SINAMICS SM150) If the converter is to be used to control permanently excited synchronous motors, order code E03 must be quoted in the order.
D02
D15
D56
D72
D77
D78
D84
D92
Siemens D 12 2006
5/3
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
E11 to E71 (SINAMICS GM150 in water-cooled IGBT version, SINAMICS GM150 in IGCT version on request) Individual certification of the converter by the relevant certifying organizations, including the extensions described under option M66
Option Description E11 Marine version with individual certificate from Germanische Lloyd (GL) includes option M66 Marine version with individual certificate from Lloyds Register (LR) includes option M66 Marine version with individual certificate from Bureau Veritas (BV) includes option M66, requires option Y75 (other auxiliary voltage than 400 V 3 AC) Marine version with individual certificate from Det Norske Veritas (DNV) includes option M66 Marine version with individual certificate from the American Bureau of Shipping (ABS) includes option M66 Marine version with individual certificate from the Chinese Classification Society (CCS) includes option M66 F77 F73
E21
E31
E51
E61
E71
Note: A combination of several individual certificates is not possible. E86 Additional analog inputs (isolated) With option E86 an additional TM31 Terminal Module is available. Its analog inputs are isolated. Multi-range transformers are used (adjustment range: 0 V to 10 V; 0 mA to 20 mA or 4 mA to 20 mA). Note: Option E86 cannot be combined with option G62 (second additional TM31 Terminal Module), as well as with options L94 and L96 (2 PT100 evaluation units). E87 Additional analog outputs (isolated) With option E87 an additional TM31 Terminal Module is available. Its analog outputs are isolated. Multi-range transformers are used (adjustment range: 0 V to 10 V; 0 mA to 20 mA or 4 mA to 20 mA). Note: Option E87 cannot be combined with option G62 (second additional TM31 Terminal Module).
F97
Note: An acceptance test of static excitation units according to options F03, F73, F77 and F97 is only possible together with the converter which must be ordered simultaneously.
5/4
Siemens D 12 2006
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
G20 to G25 Connection to other bus systems (SINAMICS GM150 in IGBT version) In the standard version the SINAMICS GM150 and SINAMICS SM150 are equipped with a PROFIBUS interface (slave). Optionally other interface modules are available on request.
Option Description G20 G21 G22 G23 G24 G25 CAN bus interface (CANopen, on request) Modbus Plus interface Modbus RTU slave interface DeviceNet interface PROFINET interface (on request) Teleservice connection (on request)
Note: For isolated analog inputs/outputs options E86 or E87 are available.
TM31 Terminal Module Digital inputs Voltage Low level (an open digital input is interpreted as low) High level Current consumption (at 24 V DC) Signal propagation delays for digital inputs Max. connectable cross-section Voltage 3 V to +30 V 3 V to +5 V
15 V to 30 V typ. 10 mA L H: approx. 50 ms H L: approx. 100 ms 1.5 mm2 24 V DC 100 mA 400 mA 1.5 mm2
Digital outputs (continuously short-circuit-proof) Max. load current per digital output Max. total current of digital outputs Max. connectable cross-section
G30 PROFIBUS master (SINAMICS GM150 with static excitation unit, see Accessories) As standard SINAMICS GM150 converters can only communicate as PROFIBUS slaves. Therefore a SIMATIC CPU with PROFIBUS master capability is used in connection with a SINAMICS GM150 converter in the static excitation unit. G61 Additional TM31 Terminal Module One TM31 Terminal Module and two TM15 Terminal Modules for integrating alarm and fault messages as well as drive signals and for communicating with a superordinate control level are already included in the standard version of the converter. If the number of signals to be monitored is not sufficient, the interface can also be extended by an additional Terminal Module. Additional digital inputs and outputs and two analog inputs and outputs are available with the TM31. The TM31 Terminal Module comprises: 8 digital inputs 4 bidirectional digital inputs and outputs 2 relay outputs with changeover contact 2 analog inputs 2 analog outputs 1 temperature sensor (KTY84-130 or PTC) The following table shows an overview of the exclusions, which must be considered when selecting options G61 or G62.
G61 G62 E86 E87 L80 to L93, L95 L94, L96
Analog inputs (a switch is used to toggle between voltage and current input) As voltage input - Voltage range - Internal resistance Ri As current input - Current range - Internal resistance Ri - Resolution Max. connectable cross-section Voltage range Max. load current Current range Max. load resistance Resolution Max. connectable cross-section Relay outputs (changeover contacts) Max. load current Max. switching voltage Max. switching power (at 250 V AC) Max. switching power (at 30 V DC) 8A 250 V AC, 30 V DC 2000 VA (cos phi = 1) 750 VA (cos phi = 0.4) 240 W (ohmic load) 100 mA 2.5 mm2 4 mA to 20 mA/20 mA to +20 mA/0 mA to 20 mA 250 Ohm 11 bit + sign 1.5 mm2 10 V to +10 V 3 mA to +3 mA 4 mA to 20 mA, 20 mA to +20 mA, 0 mA to 20 mA 500 Ohm for outputs in the range 20 mA to +20 mA 11 bit + sign 1.5 mm2 10 V to +10 V 100 kOhm
G62 Second additional TM31 Terminal Module With order code G62 a second TM31 Terminal Module can be ordered (description and exclusions under option G61).
Siemens D 12 2006
5/5
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
G63 Additional TM15 Terminal Module One TM31 Terminal Module and one TM15 Terminal Module for integrating alarm and fault messages as well as drive signals and for communicating with a superordinate control level are already included in the standard version of the converter. The number of digital inputs and outputs can be expanded with an additional TM15 Terminal Module. This is recommended if, for instance, external signals are to be read in and processed or external components are to be controlled in addition to the standard customers terminal block. The TM15 Terminal Module comprises: 24 bidirectional digital inputs and outputs (isolation in three groups of eight channels each) 24 green status LEDs for indicating the logical signal status of the relevant terminal G66 PADU8 diagnostics module (SINAMICS GM150 in IGCT version and SINAMICS SM150) The PADU8 diagnostics module reads out up to eight analog signals and up to eight digital signals from the power stack adapter of the power section and makes these available for diagnostics purposes or for further processing. The typical detection cycle of all channels in parallel is 1 ms, enabling rapid signal characteristics to be detected and diagnosed simultaneously. The detected values are transferred to an evaluation system (e.g. notebook) either by fiber-optic conductors or by an RJ11 socket. All output data are available in parallel at the fiberoptic conductor output and at the RJ11 socket. This means that measurements can be taken in parallel at the RJ11 socket without disrupting the transfer of data at the fiber-optic conductor. With option G66 a PADU8 diagnostics module is integrated in the control section of each Motor Module. G70
30 V to +30 V 30 V to +5 V 15 V to 30 V 5 mA to 11 mA L H: 50 ms H L: 100 ms 1.5 mm2 24 V DC 0.5 A L H: 50 ms H L: 150 ms L H: 100 ms H L: 225 ms
TM15 Terminal Module Digital inputs Voltage Low level (an open digital input is interpreted as low) High level Current consumption (at 24 V DC) Signal propagation delays for digital inputs, typical Max. connectable cross-section Voltage Max. load current per digital output Output delay (ohmic load) - standard - maximum Max. total current of outputs (per group) - up to 60 C - up to 50 C - up to 40 C Max. connectable cross-section 2A 3A 4A 1.5 mm2
Pulse distributor for forwarding the speed encoder signal (SINAMICS SM150) With this pulse distributor it is possible to split the encoder signal. This possibility is used, for example, when actual speed values from an HTL incremental encoder are required at various points for measured-value acquisition and processing. The pulse distributor transfers the HTL incremental encoder signals to two separate RS 422 signal outputs. The inputs are electrically isolated from the outputs. 8-pole terminal blocks are used for the connection. G71 Optical bus terminal (OBT) for PROFIBUS (SINAMICS SM150) The PROFIBUS OBT is a network component for use in optical PROFIBUS DP fieldbus networks. The individual bus stations are linked using two-phase plastic fiber-optic conductors, resulting automatically in isolation and preventing potential differences in large plants from having any impact. The OBT has three interfaces: Channel 1 is an electric RS 485 interface which is configured as a 9-pole Sub D socket and establishes the link to the converter control. Channels 2 and 3 form the optical interface. They are configured as a duplex socket and can be used for connection on the plant side to superordinate systems.
5/6
Siemens D 12 2006
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
K20 Signal lamps and start/stop button in the cabinet door With option K20, five signal lamps that display the operating status of the converter are provided in the cabinet door of the control section. Fault (red) Alarm (yellow) Operation (green) Drive ready (white) Local operation (white) Additionally a start button (green) and a stop button (red) are installed in the cabinet door if option K20 is selected. During remote operation these pushbuttons can be used to switch the drive ON and OFF. During local operation from AOP30 these pushbuttons are not active. K21 Display instruments in the cabinet door for voltage, current, speed and power also including signal lamps and start/stop button For display of process variables, analog display instruments are installed in the cabinet door indicating the measured value in %: Motor current (0 to +120%) Motor speed (120% ... 0 ... +120%) Calculated motor power (0 to +120%) Motor voltage (0 to +120%) Note: Option K21 includes option K20. K22 Display instruments in the cabinet door for current, speed, power and winding temperature also including signal lamps and start/stop button For display of process variables, analog display instruments are installed in the cabinet door indicating the measured value in %: Motor current (0 to +120%) Motor speed (120% ... 0 ... +120%) Calculated motor power (0 to +120%) Motor winding temperature (0 to 200 C) Note: Option K22 includes option K20. K50 SMC30 Sensor Module Cabinet-Mounted (SINAMICS GM150, standard for SINAMICS SM150) The SMC30 Sensor Module Cabinet-Mounted can be used to detect the actual motor speed. The signals emitted by the rotary pulse encoder are converted here and made available via the DRIVE-CLiQ interface of the closed-loop control for evaluation purposes. The following encoders are supported by the SMC30: TTL encoders HTL encoders The max. connectable conductor cross-section is 20 mm2. L08 Output reactor The output reactor is used to limit the capacitive re-charging currents of motor cables. Depending on the configuration of the power section (IGBT or IGCT technology) different cable lengths apply.
Converter Max. cable lengths without output reactor (standard) shielded Output voltage 2.3 kV to 6.6 kV SINAMICS up to 2 parallel not GM150 cables: 100 m permitted IGBT version 3 parallel cables: 80 m > 3 parallel cables: not permitted Output voltage 3.3 kV SINAMICS up to 2 parallel not GM150 cables: 100 m permitted IGCT version 3 parallel cables: on request 4 parallel cables: on request SINAMICS SM150 up to 2 parallel not cables: 50 m permitted 3 parallel cables: on request 4 parallel cables: on request 500 m not permitted 1000 m not permitted 2) unshielded with output reactor 1) (option L08) shielded unshielded
200 m
not permitted
The output reactor is located in an additional cabinet. L21 Overvoltage protection AC (static excitation unit, see Accessories) Option L21 provides an integrated overvoltage protection on the input side of type SICROWBAR.
1) Distance from converter to motor according to current load for max. 6 parallel three-wire EMC cables. 2) A sine-wave filter (option Y15) must be provided if unshielded motor cables are used. Siemens D 12 2006
5/7
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
L29 Bidirectional synchronized bypass operation (SINAMICS GM150 in IGBT version with induction motor) Option L29 offers synchronization with seamless transfer of the motor to the line and take-over of the motor from the line. The converter synchronizes the motor to the supply voltage (phase relation, frequency and amplitude). The motor is subsequently connected in parallel to the line with the S3 circuitbreaker before the output-side S2 circuit-breaker opens. L32 Automatic restart Option L32 enables the converter to be restarted after a power failure once the line supply has been restored. If such a restart is required for technical reasons, the following conditions must be taken into consideration. The 400 V 3 AC and 230 V 1 AC auxiliary supplies must not fail, so that the voltage supply to the fans and coolant pumps as well as the control is maintained. If the main supply fails, pulses are blocked and the DC link voltage is sustained by the precharging unit for a short period. It is important to distinguish between two cases here: Case A: The circuit-breaker on the input side is still switched on. If the main supply returns, the DC link voltage rises. This is detected by the closed-loop control and the controller and operation is resumed when a threshold value is exceeded.
G_D012_XX_00024
S1
S3
5
S2
Case B: The circuit-breaker on the input side has switched off. After a fixed, parameterizable time, the circuit-breaker receives an ON command. The response of the DC link voltage is then analyzed. If the DC link voltage continues to fall, the converter is shut down. If the DC link voltage rises, operation is resumed when a threshold value is exceeded. Depending on the downtime, load characteristic and moment of inertia, the drive may be caught again or the machine may need to be excited again first before operation can be resumed. With option L32 a VSM10 Voltage Sensing Module is integrated into the converter. The VSM10 detects the line voltage in phase relation, frequency and amplitude, utilizing a voltage transformer that has to be installed on the primary side of the S1 circuitbreaker (plant-side). This enables the controller and closed-loop control to detect when the main supply returns after a power failure if the circuit-breaker on the input side has dropped out. For safety reasons, a time limit is built in between the power failure and the maximum permitted line restoration time so that the drive cannot start up again uncontrolled. A signal is issued in addition when restarting that can be used to generate an acoustic warning.
Approx. 100 ms pass under consideration of the response time constants of the two circuit-breakers (opening and closing times). Within this period of time the motor is transferred from the converter to the line. This ensures a bumpless transfer of the motor to the line. If the motor is to be subsequently taken from the line and operated via the converter again, the transfer process is executed in reverse order. The converter is first run up in no-load operation and its output voltage is synchronized to the line voltage in its phase relation, frequency and amplitude. Then circuit-breaker S2 is closed before S3 is opened and the motor is isolated from the line. In this case the motor is taken over bumplessly by the converter and can either be operated under speed control or shut down under control. Variable speed operation during running up and shutting down does not produce any high starting and transient torques that could damage the drive train or cause e.g. pressure fluctuations in the process. With option L29 a VSM10 Voltage Sensing Module is integrated into the converter. The VSM10 detects the line voltage in phase relation, frequency and amplitude, utilizing a voltage transformer that has to be installed on the primary side of the S1 circuitbreaker (plant-side). It thus supplies the data for synchronization of the motor to the line and from the line to the converter. The converter control outputs the drive signals of the two circuitbreakers to be provided on the plant side. Option L08 (output reactor) or option Y15 (sine-wave filter) is additionally required for the decoupling of the converter output during the commutation process. The S3 circuit-breaker must be configured to protect the motor against overcurrents and overvoltages during line operation. If temperature sensors are fitted in the motor, these must be monitored independently (plant-side) during line operation. Attention: Option L29 is only possible if the converter output voltage is the same as the line voltage.
5/8
Siemens D 12 2006
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
L48 Grounding switch at converter input (motor-operated) If grounding on the line side is required for safety and protection reasons, a motor-operated grounding switch can be ordered with order code L48. The number of grounding switches depends on the configuration of the line supply (12-/24-pulse for SINAMICS GM150 or 6-pulse for SINAMICS SM150). For safety reasons, the converter controller locks these grounding switches against activation while voltage is still present. The control is integrated into the protection and monitoring chain of the converter. The grounding switches are inserted automatically when the standard grounding switches of the DC link are inserted. In the event of maintenance work on the converter, it must be ensured on the plant side that there is no external voltage present, e.g. auxiliary voltage for fans, the cooling system, controller and closed-loop control and any external outputs in the converter. Attention: Option L48 increases the width of the cabinet as follows: SINAMICS GM150 in IGBT version: 600 mm SINAMICS GM150 in IGCT version and SINAMICS SM150: 700 mm Note: Option L48 is available on request in connection with option U01 (converter version for NAFTA with UL listing). L49 Grounding switch at converter output (motor-operated) With certain operating modes/configurations of the load machine (e.g. drive group with gas turbines) or types of drive machine (e.g. PEM), there can be operating statuses at which there is a risk that energy will be fed back into the converter from the motor. This can lead to dangerous voltages. In these cases a motor-operated grounding switch for the converter output side can be ordered with order code L49. Where power sections are connected in parallel, the number of circuit-breakers will rise accordingly. For safety reasons, the converter controller locks the grounding switch against activation while voltage is still present. The control is integrated into the protection and monitoring chain of the converter. The grounding switches are inserted automatically when the standard grounding switches of the DC link are inserted. Attention: Option L49 increases the width of the cabinet as follows: SINAMICS GM150 in IGBT version: 600 mm SINAMICS GM150 in IGCT version and SINAMICS SM150: 700 mm Note: Option L49 is available on request in connection with option U01 (converter version for NAFTA with UL listing). L50 Cabinet lighting and service socket outlet in control section If option L50 is chosen, a universal lamp and a service socket outlet (Schuko version) are installed respectively in the cabinet panels of the control sections for Motor Modules and Active Line Modules. The voltage supply for the cabinet lighting and service socket outlet (on terminal block =.EG-X1) is provided externally. The cabinet lighting is switched on manually via a switch or automatically by an integrated motion detector. The mode is switch-selected.
Terminal =.EGX1:1 =.EGX1:2 Meaning L1 (230 V) N
Note: In connection with option U01 (converter version for NAFTA with UL listing), option L50 is configured with supply voltage 120 V. In this case the service socket outlet corresponds to the version for the USA. L51 Disconnector at converter output (SINAMICS GM150 in IGCT version and SINAMICS SM150) If a disconnection between the converter output and the drive motor is required for safety and protection reasons, a motoroperated disconnector at the converter output can be ordered with order code L51. Attention: Option L51 increases the width of the cabinet of each converter unit by 700 mm.
Siemens D 12 2006
5/9
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
L53 UPS for power supply of control (SINAMICS GM150) If there is a danger of voltage dips and short-time power failures on the plant, the drive can continue to be operated if the control is supplied by a UPS, provided that the DC link voltage does not fall below the Vd min limit. Another prerequisite is that the circuitbreaker does not switch off because of the undervoltage. This enables the drive to withstand voltage dips to short power failures, particularly when the motor has a large inertia and kinetic buffering of the DC link can be used. In the case of interruptions that lead to disconnection of the power section, the down time is reduced using the function automatic restart (option L32). The UPS is configured for a buffer time of up to 10 min. Note: In connection with option U01 (converter version for NAFTA with UL listing), option L53 is available on special request. L55 Anti-condensation heating for cabinet The anti-condensation heating is recommended at low ambient temperatures and high levels of humidity to prevent condensation. The number of 100 W switch cabinet heaters fitted depends on the number of cabinet panels. The anti-condensation heaters are controlled with a thermostat. Should the external auxiliary supply fail, this is monitored and reported by the converter for safety reasons. The supply voltage for the anti-condensation heating (110 V to 240 V AC, on terminal block =.GBX1:) must be supplied externally.
Terminal =.GBX1:1 =.GBX1:2 Meaning N L1 (110 V to 240 V)
L60 EMERGENCY STOP category 1 EMERGENCY STOP category 1 (24 V DC) for controlled shutdown in accordance with EN 60204-1/VDE 0113 T1 (IEC 60204-1). EMERGENCY STOP category 0 is set as standard for an uncontrolled shutdown. The function includes voltage disconnection of the converter output through the circuit-breaker. Consequently the motor coasts down. The EMERGENCY STOP category 1 function includes rapid shutdown of the drive through a fast stop using a ramp-down ramp to be parameterized by the user. This is followed by voltage disconnection as described for EMERGENCY STOP category 0. The EMERGENCY STOP button with protective collar is fitted in the converter cabinet door and its contacts are connected in parallel to the terminal block so that they can be integrated in parallel in a protection concept on the plant side. (terminal block =.LAX51:1A or 1C and =.LAX51:2A or 2C) Attention: On activation of the EMERGENCY STOP button, the motor is shut down uncontrolled or controlled and the main voltage on the motor is disconnected depending on either selecting category 0 or 1. Auxiliary voltages such as for the supply of external fans or anti-condensation heating, may still be present. Certain areas within the converter such as the control or auxiliaries, also remain under voltage. If all voltages have to be completely disconnected, the EMERGENCY STOP button must be integrated into a protection concept on the plant side. Therefore a NC contact is available on terminal =.LAX51:1A and =.LAX51:2A. Attention: The braking process can take considerable time even with an EMERGENCY STOP category 1. This depends on the one hand on the moment of inertia of the load and on the other hand on whether the power section on the line side is an Active Line Module (SINAMICS SM150) or a Basic Line Module (SINAMICS GM150).
5/10
Siemens D 12 2006
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
L80 2 thermistor protection relays for alarm and fault Option L80 offers two thermistor protection relays (with PTB approval) for PTC thermistors (type A) for alarm and disconnection. The power supply for the relay and the evaluation is provided within the converter. An additional TM31 Terminal Module is integrated as interface for further processing and display of the signals. Note: Option L80 cannot be combined with option G61 (additional TM31 Terminal Module).
Terminal =.LFA11:T1 =.LFA11:T2 Meaning (alarm) Connection of sensor loop Connection of sensor loop
L82 3 x 2 thermistor protection relays for alarm and fault Option L82 offers six thermistor protection relays (with PTB approval) for PTC thermistors (type A) for alarm and disconnection. The power supply for the relay and the evaluation is provided within the converter. An additional TM31 Terminal Module is integrated as interface for further processing and display of the signals. Note: Option L82 cannot be combined with option G61 (additional TM31 Terminal Module).
Terminal =.LFA11:T1 =.LFA11:T2 Meaning (alarm) Connection of sensor loop Connection of sensor loop
L81 2 x 2 thermistor protection relays for alarm and fault Option L81 offers four thermistor protection relays (with PTB approval) for PTC thermistors (type A) for alarm and disconnection. The power supply for the relay and the evaluation is provided within the converter. An additional TM31 Terminal Module is integrated as interface for further processing and display of the signals. Note: Option L81 cannot be combined with option G61 (additional TM31 Terminal Module).
Terminal =.LFA11:T1 =.LFA11:T2 Meaning (alarm) Connection of sensor loop Connection of sensor loop
L87
Terminal =.LFA21:T1 =.LFA21:T2 Meaning (alarm) Connection of sensor loop Connection of sensor loop
Rotor ground-fault monitoring (static excitation unit, see Accessories) Option L87 provides integrated ground-fault monitoring for the rotor circuit.
Siemens D 12 2006
5/11
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
L90 PT100 evaluation unit with 3 inputs The PT100 evaluation unit can monitor up to three sensors. The sensors can be connected using a two-wire or three-wire system. For all three sensors, the limits for alarm and disconnection must be set centrally. The output relays are integrated into the internal fault and shutdown sequence of the converter. An additional TM31 Terminal Module is integrated as interface for further processing and display of the signals. Note: Option L90 cannot be combined with option G61 (additional TM31 Terminal Module).
Terminal =.LJA11:1T1 to 1T3 =.LJA11:2T1 to 2T3 =.LJA11:3T1 to 3T3 Meaning PT100; sensor 1 PT100; sensor 2 PT100; sensor 3
L92 3 PT100 evaluation units each with 3 inputs (SINAMICS GM150 in IGCT version and SINAMICS SM150) Each PT100 evaluation unit can monitor up to three sensors. For all three sensors, the limits for alarm and disconnection must be set centrally. The output relays are integrated into the internal fault and shutdown sequence of the converter. An additional TM31 Terminal Module is integrated as interface for further processing and display of the signals. Note: Option L92 cannot be combined with option G61 (additional TM31 Terminal Module).
Terminal =.LJA11:1T1 to 1T3 =.LJA11:2T1 to 2T3 =.LJA11:3T1 to 3T3 Meaning PT100; sensor 1 PT100; sensor 2 PT100; sensor 3
In a two-wire system inputs xT1 and xT2 must be assigned and a bridge inserted between terminals xT2 and xT3. L91 2 PT100 evaluation units with 3 inputs each Each PT100 evaluation unit can monitor up to three sensors. For all three sensors, the limits for alarm and disconnection must be set centrally. The output relays are integrated into the internal fault and shutdown sequence of the converter. An additional TM31 Terminal Module is integrated as interface for further processing and display of the signals. Note: Option L91 cannot be combined with option G61 (additional TM31 Terminal Module).
Terminal =.LJA11:1T1 to 1T3 =.LJA11:2T1 to 2T3 =.LJA11:3T1 to 3T3 Meaning PT100; sensor 1 PT100; sensor 2 PT100; sensor 3
The sensors can be connected using a two-wire or three-wire system. In a two-wire system inputs xT1 and xT2 must be assigned and a bridge inserted between terminals xT2 and xT3.
The sensors can be connected using a two-wire or three-wire system. In a two-wire system inputs xT1 and xT2 must be assigned and a bridge inserted between terminals xT2 and xT3.
5/12
Siemens D 12 2006
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
L93 PT100 evaluation unit with 6 inputs and 2 analog outputs (outputs for display connected to control) The PT100 evaluation unit can monitor up to six sensors. The limit values can be programmed by the user for each channel. In the standard setting, the measuring channels are divided into two groups of three channels each. With motors, for example, three PT100 can be monitored in the stator windings and two PT100 in the motor bearings. Channels that are not used can be suppressed using appropriate parameter settings. The output relays are integrated into the internal fault and shutdown sequence of the converter. Additionally two freely programmable analog outputs (0/4 mA to 20 mA and 0/2 V to 10 V) are available. An additional TM31 Terminal Module is integrated as interface for further processing and display of the signals. Note: Option L93 cannot be combined with option G61 (additional TM31 Terminal Module).
Terminal =.LGA11:T11 to T13 =.LGA11:T21 to T23 =.LGA11:T31 to T33 =.LGA11:T41 to T43 =.LGA11:T51 to T53 =.LGA11:T61 to T63 Meaning PT100; sensor 1; group 1 PT100; sensor 2; group 1 PT100; sensor 3; group 1 PT100; sensor 1; group 2 PT100; sensor 2; group 2 PT100; sensor 3; group 2 Terminal =.LGA21:T11 to T13 =.LGA21:T21 to T23 =.LGA21:T31 to T33 =.LGA21:T41 to T43 =.LGA21:T51 to T53 =.LGA21:T61 to T63 Meaning PT100; sensor 1; group 3 PT100; sensor 2; group 3 PT100; sensor 3; group 3 PT100; sensor 1; group 4 PT100; sensor 2; group 4 PT100; sensor 3; group 4 =.LGA11:T2 (OUT 2) =.LGA11:I2 (OUT 2) Terminal =.LGA11:T11 to T13 =.LGA11:T21 to T23 =.LGA11:T31 to T33 =.LGA11:T41 to T43 =.LGA11:T51 to T53 =.LGA11:T61 to T63 Meaning PT100; sensor 1; group 1 PT100; sensor 2; group 1 PT100; sensor 3; group 1 PT100; sensor 1; group 2 PT100; sensor 2; group 2 PT100; sensor 3; group 2
The sensors can be connected to the PT100 evaluation unit using both a two-wire or three-wire system. In a two-wire system inputs Tx1 and Tx3 must be assigned. In a three-wire system, input Tx2 must also be connected (x = 1, 2 , ..., 6). =.LGA11:11/12/14 =.LGA11:21/22/24 =.LGA11:T1 (OUT 1) =.LGA11:I1 (OUT 1) =.LGA11:31/32/34 =.LGA11:41/42/44 Relay output limit for group 1 reached (alarm); changeover contact Relay output limit for group 1 reached (fault); changeover contact Analog output OUT 1; sensor group 1 Analog output OUT 1; sensor group 1 Relay output limit for group 2 reached (alarm); changeover contact Relay output limit for group 2 reached (fault); changeover contact Analog output OUT 2; sensor group 2 Analog output OUT 2; sensor group 2
The sensors can be connected to the PT100 evaluation unit using both a two-wire or three-wire system. In a two-wire system inputs Tx1 and Tx3 must be assigned. In a three-wire system, input Tx2 must also be connected (x = 1, 2 , ..., 6). =.LGA11:11/12/14 =.LGA11:21/22/24 =.LGA11:T1 (OUT 1) =.LGA11:I1 (OUT 1) =.LGA11:31/32/34 =.LGA11:41/42/44 =.LGA11:T2 (OUT 2) =.LGA11:I2 (OUT 2) Relay output limit for group 1 reached (alarm); changeover contact Relay output limit for group 1 reached (fault); changeover contact Analog output OUT 1; sensor group 1 Analog output OUT 1; sensor group 1 Relay output limit for group 2 reached (alarm); changeover contact Relay output limit for group 2 reached (fault); changeover contact Analog output OUT 2; sensor group 2 Analog output OUT 2; sensor group 2
The sensors can be connected to the PT100 evaluation unit using both a two-wire or three-wire system. In a two-wire system inputs Tx1 and Tx3 must be assigned. In a three-wire system, input Tx2 must also be connected (x = 1, 2 , ..., 6). =.LGA21:11/12/14 =.LGA21:21/22/24 =.LGA21:T1 (OUT 1) =.LGA21:I1 (OUT 1) =.LGA21:31/32/34 =.LGA21:41/42/44 =.LGA21:T2 (OUT 2) =.LGA21:I2 (OUT 2) Relay output limit for group 3 reached (alarm); changeover contact Relay output limit for group 3 reached (fault); changeover contact Analog output OUT 1; sensor group 3 Analog output OUT 1; sensor group 3 Relay output limit for group 4 reached (alarm); changeover contact Relay output limit for group 4 reached (fault); changeover contact Analog output OUT 2; sensor group 4 Analog output OUT 2; sensor group 4
L94 2 PT100 evaluation units each with 6 inputs and 2 analog outputs (outputs for display connected to control; SINAMICS GM150 in IGCT version and SINAMICS SM150) Option L94 offers two PT100 evaluation units as described under option L93, enabling up to 12 sensors in total to be monitored. Two additional TM31 Terminal Modules are integrated as interfaces for further processing and display of the signals and analog outputs. Note: Option L94 cannot be combined with options G61 and G62 (additional TM31 Terminal Modules), as well as with option E86 (additional analog inputs).
Siemens D 12 2006
5/13
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
L95 PT100 evaluation unit with 6 inputs for explosion-proof motors and 2 analog outputs (outputs for display connected to control) Six evaluation units are available for use in explosion-proof motors Zone 2, Zone 22 (non-conductive dusts) Div. 2 and safe areas (inherently safe input: [EEx ia] IIC). The resistance thermometers (PT100, PT500, PT1000) can be operated in a two-wire, three-wire or four-wire system. The six evaluation units are arranged in two groups of three units each. For each group the alarm and fault messages are combined together and integrated into the alarm and fault reporting chain of the converter. Furthermore, a temperature measured value is led to an analog input of the converter in each group so that it is available to the converter control for measurement and display purposes. An additional TM31 Terminal Module is integrated as interface for further processing and display of the signals. L96 2 PT100 evaluation units each with 6 inputs for explosion-proof motors and 2 analog outputs (outputs for display connected to control; SINAMICS GM150 in IGCT version and SINAMICS SM150) Two times six evaluation units are available for use in explosionproof motors Zone 2, Zone 22 (non-conductive dusts) Div. 2 and safe areas (inherently safe input: [EEx ia] IIC). The resistance thermometers (PT100, PT500, PT1000) can be operated in a two-wire, three-wire or four-wire system. The evaluation units are arranged in groups of three units each. For each group the alarm and disconnection messages are arranged together and integrated into the alarm and fault reporting chain of the converter. Furthermore, a temperature measured value is led to an analog input of the converter in each group so that it is available to the converter control for measurement and display purposes. Two additional TM31 Terminal Modules are integrated as interfaces for further processing and display of the signals and analog outputs. Note: Option L96 cannot be combined with options G61 and G62 (additional TM31 Terminal Modules), as well as with option E86 (additional analog inputs).
Terminal =.LHA11:10/11/12/14 =.LHA12:10/11/12/14 =.LHA13:10/11/12/14 Terminal =.LHA21:10/11/12/14 =.LHA22:10/11/12/14 =.LHA23:10/11/12/14 Meaning PT100; sensor 1; group 1 PT100; sensor 2; group 1 PT100; sensor 3; group 1 Terminal =.LHA21:10/11/12/14 =.LHA22:10/11/12/14 =.LHA23:10/11/12/14 Meaning PT100; sensor 1; group 1 PT100; sensor 2; group 1 PT100; sensor 3; group 1 Meaning PT100; sensor 1; group 1 PT100; sensor 2; group 1 PT100; sensor 3; group 1
Note: Option L95 cannot be combined with option G61 (additional TM31 Terminal Module), as well as with option U01 (converter version for NAFTA with UL listing).
Terminal =.LHA11:10/11/12/14 =.LHA12:10/11/12/14 =.LHA13:10/11/12/14 Meaning PT100; sensor 1; group 1 PT100; sensor 2; group 1 PT100; sensor 3; group 1
The sensors can be connected to the PT100 evaluation unit in either a two-wire, three-wire or four-wire system. In a two-wire system the inputs 10 and 12 must be connected, in a three-wire system the inputs 10, 11 and 12 and in a four-wire system the inputs 10, 11, 12 and 14 must be connected. Parameterization is done using software.
Meaning PT100; sensor 1; group 1 PT100; sensor 2; group 1 PT100; sensor 3; group 1
Meaning PT100; sensor 1; group 1 PT100; sensor 2; group 1 PT100; sensor 3; group 1
The sensors can be connected to the PT100 evaluation unit in either a two-wire, three-wire or four-wire system. In a two-wire system the inputs 10 and 12 must be connected, in a three-wire system the inputs 10, 11 and 12 and in a four-wire system the inputs 10, 11, 12 and 14 must be connected. Parameterization is done using software.
5/14
Siemens D 12 2006
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
M10 Safety closing/interlocking system The safety closing/interlocking system is based on the key transfer system from Castell and is used in addition to the electromagnetic door locking system provided as standard. To obtain the coded key of the key exchange unit, the circuit-breaker must first be opened. The opened circuit-breaker releases the key to the key exchange unit, which in turn releases the keys to the converter cabinet doors of the power section. This ensures that the converter is isolated from the medium voltage and that the medium voltage is no longer present in the cabinet. As long as the cabinet doors are not closed again and the keys of the converter cabinet doors are not put back into the key exchange unit, the key for the medium voltage switch will not be released and the medium voltage switch cannot be activated again. M11 Dust protection (SINAMICS GM150, air-cooled) With option M11 the cabinet doors are fitted with additional filter mats to prevent the ingress of dangerous dust deposits on the power section components. The filter mats are fitted to the outside of the cabinet doors, which means that they can be replaced during operation. The amount of dust in the filter mats is determined constantly by a differential pressure monitor. A maintenance request is issued in plenty of time before the filter mats get clogged up. When replacing the filter mats, it must be ensured that no dust gets into the cabinet through the air pulled in by the cabinet fans as they run. M13 Connection of power cables to converter input from top (SINAMICS GM150 in IGBT version) Given suitable installation conditions, option M13 enables the line-side power cables to be introduced into the cabinet from top. Attention: Option M13 increases the width of the cabinet by 600 mm. If option Y15 (sine-wave filter) is selected simultaneously, no increase of the width is necessary; then the dimensions given in the technical data sections apply. M32 Customers terminal block with cage clamp terminals for signal cables up to 2.5 mm2 The signal cable is normally connected directly to the terminals of the TM31 or TM15 Terminal Modules. The maximum connectable cross-section for TM31 and TM15 is limited to 1.5 mm2. With option M32, the signals are led out to a terminal block where connection takes place via cage clamp terminals. In this case connection cross-sections of up to 2.5 mm2 are permitted. Note: It is not possible to lead out the signals of additional Terminal Modules (options G61, G62 and L80 to L96). M33 Customers terminal block with screw terminals for signal cables up to 2.5 mm2 The signal cable is normally connected directly to the terminals of the TM31 or TM15 Terminal Modules. The maximum connectable cross-section for TM31 and TM15 is limited to 1.5 mm2. With option M33, the signals are led out to a terminal block where connection takes place via screw terminals. In this case connection cross-sections of up to 2.5 mm2 are permitted. Note: It is not possible to lead out the signals of additional Terminal Modules (options G61, G62 and L80 to L96). M34 Connection of auxiliary voltage and signal cables from top (SINAMICS GM150 in IGBT version) Given suitable installation conditions, option M34 enables the auxiliary supply and the signal cables to be introduced into the cabinet from top.
Siemens D 12 2006
5/15
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
M42 IP42 degree of protection (SINAMICS GM150 in air-cooled IGBT version) With option M42, the degree of protection of the air-cooled converters can be enhanced (IP22 is standard). Additional finemeshed grilles where the air comes in and goes out prevent the ingress of solid matter with diameters > 1.0 mm. M54 IP54 degree of protection (SINAMICS GM150 in water-cooled IGBT version) With option M54, the degree of protection of the water-cooled converters can be enhanced (IP43 is standard). Losses within the cabinet that cannot be dissipated directly through the coolant (thermal radiation) are dissipated by an additional internal air circuit with an air-water heat exchanger. M66 Marine version with type certificate (SINAMICS GM150, water-cooled) With option M66, the version of the converter meets the requirements of the following classification organizations: Lloyds Register American Bureau of Shipping Germanischer Lloyd Bureau Veritas Det Norske Veritas Chinese Classification Society. Option M66 includes a strengthened mechanical version of the cabinet, handrails below the operator panel and a mechanical locking of the cabinet doors. The cabinet is provided in the IP44 degree of protection and includes a cabinet anti-condensation heating (option L55). It is supplied with a strengthened base frame which can be welded to the ship floor to ensure that the converter is securely located. Note: The strengthened base frame increases the height of the converter by 100 mm. Note: If the converter is used for a safety-relevant (essential service) drive on the ship, individual certification is required in addition (see options E11 to E71). M78 Connection of power cables to converter output from top (SINAMICS GM150 as IGBT version) Given suitable installation conditions, option M78 enables the motor-side power cables to be introduced into the cabinet from top. Option M78 includes option M13 (connection of power cables to converter input from top). Attention: Option M78 increases the width of the cabinet by 600 mm. If option Y15 (sine-wave filter) is selected simultaneously, no increase of the width is necessary; then the dimensions given in the technical data sections apply.
M61 Redundant fan in power section (SINAMICS GM150, air-cooled) To improve system availability, it is possible to equip the converter with an additional redundantly operating fan. If a fan within the converter cabinet fails, this is immediately detected by the differential pressure in the cabinet and the redundant fan is activated by the converter control without the converter and hence the drive system tripping. This enables production down times or interruptions to be avoided and replacement of the faulty fan to be postponed until the next scheduled shutdown. M64 Converter prepared for connection to an external exhaust air system, with internal cabinet fans (SINAMICS GM150, air-cooled) Retaining the internal cabinet fans ensures that the volume of cool air required for cooling can be supplied without the risk of air distribution problems. If the exhaust air is led in a duct system over long sections or even around bends, the pressure drop that arises in this duct system must be compensated by additional fans within the exhaust air system. Suitable flange connections for connecting the converter to an external exhaust air system are located in the roof part of the cabinet.
5/16
Siemens D 12 2006
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
N13 Circuit-breaker at converter input (SINAMICS GM150 as IGBT version; IGCT version on request) Option N13 provides integrated circuit-breakers. Option N13 is particularly important in the retrofit business where existing circuit-breakers do not meet requirements (tripping times, undervoltage coil). The circuit-breakers are installed below the Basic Line Module in the converter cabinet and are thus located on the secondary side of the line-side transformer. Note: In connection with option U01 (converter version for NAFTA with UL listing), option N13 is available on special request. N15 24-pulse Basic Line Module (SINAMICS GM150) For particularly high requirements regarding low line harmonic distortions, the power sections of voltage ranges 2.3 kV, 3.3 kV and 4.16 kV can be supplied with a 24-pulse Basic Line Module. Converters of higher power ranges with power sections connected in parallel and converters of voltage ranges 6.0 kV and 6.6 kV can be operated with a 24-pulse configuration without the need to select option N15. The converter transformer required at the medium-voltage level must be designed as a five-winding transformer, or else two two-tier transformers must be provided. Vector groups and winding displacements must be engineered accordingly. Attention: With option N15 the width of the converter cabinet for SINAMICS GM150 in IGBT version increases by 600 mm. N20 Capacitor trip device 110 V to 120 V DC (SINAMICS GM150 as IGBT version) The capacitor trip device is used if the existing circuit-breaker has no undervoltage coil and cannot be retrofitted with one. It is installed in the converter and has the following functions: Monitoring of the auxiliary voltage supply of the circuit-breaker on the plant side Monitoring of the own internal voltage supply Locking of the circuit-breaker in the OFF position if there is insufficient voltage The capacitor trip device ensures that the circuit-breaker on the plant side can still be safely disconnected even if there is a power failure or the normal OFF command is not effective, e.g. because of a wire break. Note: Option N20 cannot be combined with option U01 (converter version for NAFTA with UL listing). N21 Capacitor trip device 230 V DC (SINAMICS GM150 as IGBT version) The capacitor trip device is used if the existing circuit-breaker has no undervoltage coil and cannot be retrofitted with one. It is installed in the converter and has the following functions: Monitoring of the auxiliary voltage supply of the circuit-breaker on the plant side Monitoring of the own internal voltage supply Locking of the circuit-breaker in the OFF position if there is insufficient voltage The capacitor trip device ensures that the circuit-breaker on the plant side can still be safely disconnected even if there is a power failure or the normal OFF command is not effective, e.g. because of a wire break. Note: Option N21 cannot be combined with option U01 (converter version for NAFTA with UL listing). N22 Switch on input side (static excitation unit, see Accessories) If option N22 is selected, a switch which is controlled by the static excitation unit itself is integrated on the input side. On the versions for brushless reverse field excitation this switch is configured as a contactor, on the versions for slip-ring excitation as a disconnector. Note: If this switch is not available, an external switch must be provided.
Siemens D 12 2006
5/17
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
N30 to N33 Controlled outgoing feeder for auxiliaries 400 V 3 AC/480 V 3 AC A controlled outgoing feeder for the operation of external auxiliary equipment, e.g. separate fans on the motor or pumps/oil supplies, is available in the converter. It is controlled and is fused by motor circuit-breakers. The voltage supply required for the drive must be provided externally. Depending on the drive power that is required, four different outgoing feeders are available. The contactor is switched on with the ON command at the converter and switched off with the OFF command.
Option Description N30 Controlled outgoing feeder for auxiliaries 400 V 3 AC 50 Hz, max. 5 kW (cos phi = 0.8; setting range of motor circuitbreaker from 7 A to 10 A) Controlled outgoing feeder for auxiliaries 400 V 3 AC 50 Hz, max. 7 kW (cos phi = 0.8; setting range of motor circuitbreaker from 14 A to 20 A) Controlled outgoing feeder for auxiliaries 400 V 3 AC 50 Hz, max. 11 kW (cos phi = 0.8; setting range of motor circuitbreaker from 20 A to 25 A) Controlled outgoing feeder for auxiliaries 400 V 3 AC 50 Hz, max. 16.5 kW (cos phi = 0.8; setting range of motor circuitbreaker from 28 A to 40 A)
N35 to N38 Controlled outgoing feeder for auxiliaries 230 V 1 AC/120 V 1 AC A controlled outgoing feeder protected by miniature circuitbreakers is available in the converter for controlling external auxiliaries, e.g. the anti-condensation heating for the motor. The voltage supply required for the drive, e.g. for the anti-condensation heating, must be provided externally. Depending on the power that is required, four different outgoing feeders are available. The contactor is switched off with the ON command at the converter and switched on with the OFF command.
Option Description N35 Controlled outgoing feeder for auxiliaries 230 V 1 AC 50 Hz, max. 1.2 kW or 120 V 1 AC 60 Hz, max. 1 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC 50 Hz, max. 2.2 kW or 120 V 1 AC 60 Hz, max. 1.5 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC 50 Hz, max. 3.5 kW or 120 V 1 AC 60 Hz, max. 2.1 kW Controlled outgoing feeder for auxiliaries 230 V 1 AC 50 Hz, max. 4.5 kW or 120 V 1 AC 60 Hz, max. 2.8 kW
N31
N36
N32
N37
N33
N38
Note: Other voltages are also possible taking into account that the available power will change. Note: It is not possible to combine several options (N30 to N33).
Auxiliary voltage supply =.GCX1:1 L1 =.GCX1:2 L2 =.GCX1:3 L3 Outgoing feeder for auxiliaries =.GCX1:4 L1 =.GCX1:5 L2 =.GCX1:6 L3 Circuit-breaker external supply ON =.GCX2:1 Relay contact max. 60 V DC =.GCX2:2
5/18
Siemens D 12 2006
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
T58, T60, T80, T85, T90, T91 Rating plate languages As standard the rating plate is supplied in two languages (English/German). Other languages can be ordered using the following order codes.
Option Description T58 T60 T80 T85 T90 T91 Rating plate in English/French Rating plate in English/Spanish Rating plate in English/Italian Rating plate in English/Russian (on request) Rating plate in English/Japanese (on request) Rating plate in English/Chinese (on request)
W02 Cooling unit with redundant stainless steel plate-type heat exchangers (with water cooling) The cooling unit is used to dissipate the power loss from the converter and consists of two cooling circuits: the internal cooling circuit with deionized water and the external raw-water circuit for dissipating the power loss. In the standard version the internal cooling circuit has two redundantly operating circulation pumps and one stainless steel plate-type heat exchanger. With option W02, a second stainless steel plate-type heat exchanger is integrated to enable fully redundant operation. W11 Cooling unit with one titanium plate-type heat exchanger (with water cooling) If the raw-water described in the technical data is not available for the cooling unit, option W11 must be selected. This is required in the case of aggressive raw-water such as seawater, for instance. With option W11, a titanium plate-type heat exchanger is installed instead of the stainless steel plate-type heat exchanger. The three-way valve for preventing condensation and the necessary pipe connections are still made of stainless steel. Attention: When option W11 is selected, the piping on the rawwater side is made of stainless steel, not titanium. W12 Cooling unit with redundant titanium plate-type heat exchangers (with water cooling) With option W12, two fully redundantly operating titanium platetype heat exchangers are integrated for the internal cooling circuit (other characteristics as described under option W11). Attention: When option W12 is selected, the piping on the rawwater side is made of stainless steel, not titanium. W14 Converter without cooling unit, plant scope (with water cooling) When option W14 is selected, the water-cooled converter is supplied without a cooling unit. The necessary cooling system must be provided on the plant side. Note: Option W14 reduces the width and weight of the cabinet (relevant data available on request). W20 Raw-water connection from bottom (SINAMICS GM150 in IGBT version) Option W20 enables the raw-water for the cooling unit to be supplied from bottom through the cabinet floor with a flange connection. The necessary counterflanges are included as a pack with the cooling unit. Note: With water-cooled converters in IGBT technology, the rawwater connection is supplied to the cooling unit through the side panel from the left-hand side. With converters in IGCT technology, the raw-water connection is supplied as standard to the cooling unit from bottom.
Note: It is not possible to combine several options (T58 to T91). U01 Converter version for NAFTA with UL listing A converter version for the North American market is supplied with option U01. It is approved and listed by the Underwriter Laboratories (UL). Option U01 is only available for SINAMICS GM150 in an air-cooled IGBT version in the voltage classes 2.3 kV, 3.3 kV and 4.16 kV. Following options are included as standard in option U01: - M10 (safety closing/interlocking system) - M11 (dust protection) - T58 (rating plate in English/French) Furthermore the converters in NAFTA version have an auxiliary voltage connection for 480 V 3 AC/120 V 1 AC. Both auxiliary voltages must be made available on the plant side. In connection with option U01, option L50 (cabinet lighting and service socket outlet in the control section) is configured with supply voltage 120 V. In this case the service socket outlet corresponds to the version for the USA. Following options cannot be combined with option U01: - N20 and N21 (capacitor trip device) - L95 (PT100 evaluation unit with 6 inputs for explosion-proof motors) Following options are available in connection with option U01 on special request: - N13 (circuit-breaker at converter input) - L48 and L49 (grounding switch at converter input and output) - E01 and E02 (control of separately excited synchronous motors) - L53 (UPS for power supply of control)
Siemens D 12 2006
5/19
Description of options
SINAMICS GM150/SINAMICS SM150
Description of options
Options (continued)
Y09 Special paint finish according to RAL.... Converters are supplied as standard in RAL 7035 (light gray). A special color must be specified in plain text when ordering. In the case of the SINAMICS GM150 air-cooled version, the fans are still finished in RAL 7035 even if the cabinet is in a special color. Y10 Customer-specific circuit diagrams The circuit diagrams are given customer-specific headers. The data for the header must be specified in plain text (up to three lines of 45 characters per line). Y15 Y17 Line reactor (static excitation unit, see Accessories) With option Y17 a line reactor is integrated to protect against excessive harmonic currents and to limit the line harmonic distortions. The exact values for the reactor must be specified in plain text as they are dependent on the supplying network. Y40 Raw-water data deviates from technical data (with water cooling, on request) With option Y40, raw-water whose data does not conform to the technical data can also be used in water-cooled converters (for specification, see the section cooling unit in chapter Configuration). Deviations from the values indicated in the specification must be clarified in advance. Y75 Auxiliary voltage other than 400 V 3 AC (SINAMICS GM150) An auxiliary supply of 400 V 3 AC must be provided on the plant side to supply voltage to the fans, controller and closed-loop control and protection and monitoring units and to precharge the DC link. If the auxiliary supply on the plant differs from this value, option Y75 for matching the voltage must be selected. In this case the three-phase current supply on the plant side which differs from the standard version is adapted with three individual transformers to the required voltage level. Tappings from 200 V 3 AC to 690 V 3 AC are available for this purpose. The auxiliary voltage and frequency available at the place of installation must be specified in plain text so that the required matching transformers can be configured. The current required for the auxiliary supply can be determined from the data for the current requirement at 400 V 3 AC (see technical data, conversion to existing auxiliary voltage). Note: In case of isolated networks the maximum supply voltage is 500 V 3 AC. Note: Connection to the matching transformers is only possible from the rear of the converter.
Auxiliary voltage supply =.EA1-Q11:1 with sine-wave (option Y15) shielded filter 1) =.EA1-Q11:3 =.EA1-Q11:5 =.EB-X1:1 =.EB-X1:2 1000 m L1 L2 L3 L1 N Control, protection and monitoring unit Supply voltage for Fans, precharging of DC link
Sine-wave filter (SINAMICS GM150 in IGBT version) Sine-wave filters are needed if the converter is used in the retrofit business, where existing motors shall be operated with variable speed or where the operation of non-Siemens motors is intended and no special measures for converter operation can be made. Furthermore, sine-wave filters are needed when unshielded motor cables are used. The sine-wave filters supply the motors with almost sine-wave motor currents and voltages so that the operation of standard motors is possible. Standard cables (without EMC shielding) can also be used between the sine-wave filter and the motor. The voltage harmonic distortion at an output frequency of 50 Hz is less than 5% when sine-wave filters are used. If the sine-wave filter is used, the power of the converter must be reduced (see technical data). It must also be remembered that only machines with square-law load characteristics (e.g. pumps, fans) can be operated. Field weakening operation is not permitted. Possible rated output frequencies are limited to the range 30 Hz to max. 66 Hz. The frequency setting range is 1:10. Note: The rated motor current, the motor current in the operating point and the motor no-load current must be specified in plain text when ordering filters.
Converter Max. cable lengths without sine-wave filter (standard) shielded SINAMICS GM150 IGBT version unshielded Output voltage 2.3 kV to 6.6 kV up to 2 par- not permitted 1000 m allel cables: 100 m 3 parallel cables: 80 m >3 parallel cables: not permitted
unshielded
Attention: Option Y15 increases the width of the cabinet (for dimensions see technical data).
1) Distance from converter to motor according to current load for max. 6 parallel three-wire EMC cables.
5/20
Siemens D 12 2006
Accessories
6
6/2 6/2 6/2 6/3 6/6 6/10 6/11 6/12 Accessories for grounding and short-circuiting the converter Accessories for replacing phase modules, IGCTs and diodes Static excitation units Static excitation units for brushless reverse field excitation Static excitation units for slip-ring excitation STARTER drive/commissioning software Drive ES engineering system SIMOTION SCOUT engineering system
Siemens D 12 2006
Accessories
SINAMICS GM150/SINAMICS SM150
Accessories for grounding and short-circuiting the converter Accessories for replacing phase modules, IGCTs and diodes
Overview
Accessories for grounding and short-circuiting the converter for commissioning and maintenance work For safety reasons, devices for grounding and short-circuiting the converter are required for work on the converter in the deenergized state (DIN EN 61230/VDE 0683-100 (IEC 61230)). They are required for commissioning or maintenance work, for example, as well as for replacing fans or power cards/phase modules. As some of this work has to be performed by operator personnel with the relevant training, the specified tools must be available on the plant side. If these devices are not available, the work must not be performed due to the electrical hazards. In the case of SINAMICS GM150 and SINAMICS SM150, spherical grounding points are fitted on the input and output side in the area of the connecting bar which can be short-circuited and grounded with an appropriate three-pole grounding device (grounding harness). As a rule, this must be done in the deenergized state for all work (in the case of converters with a power section connected in parallel at both supply points or motor feeders). If appropriate devices are not available on the plant side, the relevant converter accessories must be supplied in the required quantity.
Overview
Accessories for replacing phase modules, IGCTs and diodes (SINAMICS GM150 in IGCT version and SINAMICS SM150) The phase modules of the converters with IGCT power semiconductors SINAMICS GM150 in IGCT version and SINAMICS SM150 can be replaced as a unit by trained personnel. To replace, the entire phase module must be extracted from the converter using a special lifting tool and transported on a stacker truck. In addition, a tool kit can be ordered for unloading the module column to replace the IGCT, as well as gripping pliers for replacing freewheel diodes.
Please note in this case that the number of three-pole grounding devices required is dependent on the number of supplying three-phase current systems. One grounding device per threephase current system is required. If there is a risk of power being supplied from the motor side back into the converter, one grounding device per three-phase current system must be fitted here as well.
Overview
The following versions are available as static excitation units for SINAMICS GM150 and SINAMICS SM150: Static excitation unit for separately excited synchronous motors with brushless reverse field excitation Static excitation unit for separately excited synchronous motors with slip-ring excitation Both versions are controlled by the converter via a PROFIBUS interface. A static excitation unit must always be ordered together with the converter but it has its own order number. Add -Z to the order number of the converter and specify order code E01 or E02. The static excitation unit cannot be ordered on its own. Note: Option G30 (PROFIBUS master) must be ordered in connection with SINAMICS GM150.
6/2
Siemens D 12 2006
Accessories
SINAMICS GM150/SINAMICS SM150
Static excitation units for brushless reverse field excitation
Accessories
PROFIBUS connection cable between basic device and static excitation unit
Designation PROFIBUS cable Connector for PROFIBUS without PG/PC connection Connector for PROFIBUS with PG/PC connection Order No. 6XV1830-0EH10 6ES7972-0BA41-0XA0 6ES7972-0BB41-0XA0
Options
When ordering a converter with options, add -Z to the order number of the device, followed by the order code(s) for the desired option(s). In the following tables, related options are arranged in groups. Whether the options can be combined or are mutually exclusive is indicated within these groups. A detailed description of the options can be found in the chapter Description of options.
6
M11 M54
Enhanced degree of protection for cabinets Dust protection IP54 degree of protection 1) M11 M54
1) Option M54 cannot be combined with options M13, M78 or M34. Connection of power and signal cables 1) Connection of power cables to converter input from (on request) top 2) top 2) M13 M78 M34 M13 M78 M34
1) Options M13, M78 and M34 cannot be combined with option M54. 2) If options M13 and/or M78 are selected, the specified width of the cabinets increases by approx. 400 mm. If option M66 is selected simultaneously, the cabinet is 900 mm wide. PROFIBUS communication (SINAMICS GM150) PROFIBUS master G30
1) Option M66 is available only for version 6RN7031-1RH32-5AA0-Z. Options can be combined Options are mutually exclusive
Siemens D 12 2006
6/3
Accessories
SINAMICS GM150/SINAMICS SM150
Static excitation units for brushless reverse field excitation
Options (continued)
Documentation (standard: PDF format in English on CD-ROM) Documentation in German Circuit diagrams, terminal diagrams and dimension drawings in DXF format 1) One set of printed documentation (multiple orders possible) Documentation in Russian (on request) Documentation in Italian (on request) Documentation in French (on request) Documentation in Spanish Documentation in Chinese Documentation in Japanese (on request) Circuit diagrams with customer-specific description field (plain text required) 1) D00 D02 D15 D56 D72 D77 D78 D84 D92 Y10 D00 D02 D15 D56 D72 D77 D78 D84 D92 Y10
1) The equipment-specific documents (circuit diagrams etc.) are available only in English/German. Rating plate language (standard: English/German) T58 T58 T60 T80 T85 T90 T91 T60 T80 T85 T90 T91
Rating plate in English/French Rating plate in English/Spanish Rating plate in English/Italian Rating plate in English/Russian (on request) Rating plate in English/Japanese (on request) Rating plate in English/Chinese (on request)
Auxiliary voltage supply Auxiliary voltage other than 400 V 3 AC (primary voltage must be indicated in plain text) Y75
Converter acceptance tests in presence of customer Visual acceptance of converter 1) Functional acceptance of converter with inductive load 1) Acceptance of insulation test of the converter 1) Customer-specific converter acceptance tests (on request) 1) F03 F73 F77 F97
F03
F73
F77
F97
1) An acceptance test of static excitation units is only possible together with the converter which must be ordered simultaneously. Other options Cabinet lighting and service socket outlet in control section Anti-condensation heating for cabinet Special paint finish according to RAL .... (in a color other than RAL 7035; plain text required) L50 L55 Y09 L50 L55 Y09
6/4
Siemens D 12 2006
Accessories
SINAMICS GM150/SINAMICS SM150
Static excitation units for brushless reverse field excitation
Technical data
Brushless reverse field excitation Rated current Supply voltage Voltage range Rated supply frequency Frequency range Power loss at rated current (SIMOTRAS HD) Electronics power supply Fan power supply Max. current requirement of auxiliary supply 50/60 Hz 230 V AC Max. current requirement of auxiliary supply 50/60 Hz 400 V 3 AC Cooling air requirement Sound pressure level LpA Measuring surface level Ls Cable cross-sections, line-side, max. connectable per phase A A m3/s dB(A) dB(A) mm2 (DIN VDE) Hz Hz kW V Type A V 6RN7030-1RH31-3AA0 130 690 3 AC 110 V 10% to 500 V +10% 50/60 45 to 65 1.3 400 2 AC, 1 A or 230 1 AC, 2 A without fan 16 < 73 16 1 35 to 240 6RN7030-2RH32-5AA0 250 690 3 AC 110 V 10% to 500 V +10% 50/60 45 to 65 2 1.3 400 2 AC, 1 A or 230 1 AC, 2 A without fan 16 < 73 16 1 70 to 240 1 2/0 AWG to 500 MCM 1 70 to 240 1 2/0 AWG to 500 MCM 1 70 1 2/0 AWG IP42 600 2200 600 200 6RN7031-1RH32-5AA0-Z M66 250 690 3 AC 110 V 10% to 500 V +10% 50/60 45 to 65 1.3 400 2 AC, 1 A or 230 1 AC, 2 A 50 Hz 400 V 3 AC, 0.24 A 60 Hz 460 V 3 AC, 0.24 A 16 6 0.85 < 73 16 1 70 to 240 1 2/0 AWG to 500 MCM 1 70 to 240 1 2/0 AWG to 500 MCM 1 70 1 2/0 AWG IP44 900 2200 600 200
AWG/MCM 1 2 AWG to 500 MCM (NEC, CEC) Cable cross-sections, motor-side, max. connectable per phase mm2 (DIN VDE) 1 35 to 240
AWG/MCM 1 2 AWG to 500 MCM (NEC, CEC) PE connection, max. connection cross-section at enclosure with M12 screw Degree of protection Dimensions (with cabinet doors and side panels) Width Height Depth Weight mm mm mm kg 600 2200 600 200 mm2 (DIN VDE) 1 70
Siemens D 12 2006
6/5
Accessories
SINAMICS GM150/SINAMICS SM150
Static excitation units for slip-ring excitation
Accessories
PROFIBUS connection cable between basic device and static excitation unit
Designation PROFIBUS cable Connector for PROFIBUS without PG/PC connection Connector for PROFIBUS with PG/PC connection Order No. 6XV1830-0EH10 6ES7972-0BA41-0XA0 6ES7972-0BB41-0XA0
Options
When ordering a converter with options, add -Z to the order number of the device, followed by the order code(s) for the desired option(s).
In the following tables, related options are arranged in groups. Whether the options can be combined or are mutually exclusive is indicated within these groups. A detailed description of the options can be found in the chapter Description of options.
N22 Y17
Input-side options Switch on input side 1) (configured as a disconnector) Line reactor (plain text required) N22 Y17
1) Option N22 is not available for the compact version 6RN7011-3SE41-2AA0. In this case a switch must be provided on the plant side. Protection functions Overvoltage protection AC 1) Insulation monitoring device for rotor system L21 L87 L21 L87
1) Option L21 is not available for the compact version 6RN7011-3SE41-2AA0. In this case, AC overvoltage protection must be provided on the plant side. Otherwise a connection voltage of 200 V must not be exceeded. Enhanced degree of protection for cabinets Dust protection IP54 degree of protection 1) M11 M54 M11 M54
1) Option M54 cannot be combined with options M13, M78 or M34. Ventilation version Redundant fan in power section 1) M61
1) If option M61 is selected, the specified height of the cabinets changes. Option M61 is not available for the compact version 6RN7011-3SE41-2AA0. Options can be combined Options are mutually exclusive
6/6
Siemens D 12 2006
Accessories
SINAMICS GM150/SINAMICS SM150
Static excitation units for slip-ring excitation
Options (continued)
Connection of power and signal cables 1) Connection of power cables to converter input from (on request) top 2) top 2) M13 M78 M34 M13 M78 M34
1) Options M13, M78 and M34 cannot be combined with option M54. 2) If options M13 and/or M78 are selected, the specified width of the cabinets increases by approx. 400 mm. Options M13 and M78 are not available for the compact version 6RN7011-3SE41-2AA0. PROFIBUS communication (SINAMICS GM150) PROFIBUS master G30
1) Option M66 is available only for version 6RN7011-5SE36-0AA0-Z. Option M66 cannot be combined with options M61 and L87. Insulation monitoring must be provided externally. Documentation (standard: PDF format in English on CD-ROM) Documentation in German Circuit diagrams, terminal diagrams and dimension drawings in DXF format 1) One set of printed documentation (multiple orders possible) Documentation in Russian (on request) Documentation in Italian (on request) Documentation in French (on request) Documentation in Spanish Documentation in Chinese Documentation in Japanese (on request) Circuit diagrams with customer-specific description field (plain text required) 1) D00 D02 D15 D56 D72 D77 D78 D84 D92 Y10 D00 D02 D15 D56 D72 D77 D78 D84 D92 Y10
1) The equipment-specific documents (circuit diagrams etc.) are available only in English/German. Options can be combined Options are mutually exclusive
Siemens D 12 2006
6/7
Accessories
SINAMICS GM150/SINAMICS SM150
Static excitation units for slip-ring excitation
Options (continued)
Rating plate language (standard: English/German) Rating plate in English/French Rating plate in English/Spanish Rating plate in English/Italian Rating plate in English/Russian (on request) Rating plate in English/Japanese (on request) Rating plate in English/Chinese (on request) T58 T60 T80 T85 T90 T91 T58 T60 T80 T85 T90 T91
Auxiliary voltage supply Auxiliary voltage other than 400 V 3 AC (primary voltage must be indicated in plain text) Y75
Converter acceptance tests in presence of customer Visual acceptance of converter 1) F03 F73 F77 F97
F03
F73
F77
F97
Functional acceptance of converter with inductive load 1) Acceptance of insulation test of the converter 1) Customer-specific converter acceptance tests (on request) 1)
1) An acceptance test of static excitation units is only possible together with the converter which must be ordered simultaneously. Other options Cabinet lighting and service socket outlet in control section Anti-condensation heating for cabinet Special paint finish according to RAL .... (in a color other than RAL 7035; plain text required) Options can be combined Options are mutually exclusive L50 L55 Y09 L50 L55 Y09
6/8
Siemens D 12 2006
Accessories
SINAMICS GM150/SINAMICS SM150
Static excitation units for slip-ring excitation
Technical data
Slip-ring static excitation unit Type 6RN70115SE36-0AA0 600 400 3 AC 20 to +15 50/60 45 to 65 1.8 6RN70115SE36-0AA0-Z M66 600 460 3 AC 20 to +15 50/60 45 to 65 1.8 6RN70112SE41-2AA0 1200 460 3 AC 20 to +15 50/60 45 to 65 4.7 6RN70113SE41-2AA0 1200 460 3 AC 20 to +15 50/60 45 to 65 4.7 6RN70111SH42-0AA0 2000 690 3 AC 20 to +10 50/60 45 to 65 8.2 Rated direct current Supply voltage Voltage range Rated supply frequency Frequency range Power loss at rated direct current (SIMOREG DC master) Electronics power supply Fan power supply A V % Hz Hz kW
V V
230 1 AC, 2 A 400 3 AC, 50 Hz, 0.3 A 460 3 AC, 60 Hz, 0.3 A
400 2 AC, 1 A or 230 1 AC, 2 A 400 3 AC, 50 Hz, 0.55 A 460 3 AC, 60 Hz, 0.55 A 16
230 1 AC, 2 A
230 1 AC, 2 A
230 1 AC, 2 A
230 1 AC, 230 1 AC, 400 3 AC, 50 Hz, 50/60 Hz, 2.6/3.3 A 50/60 Hz, 2.6/3.3 A 1.0 A 460 3 AC, 60 Hz, 1.25 A 6 6 3
Max. current requirement of auxiliary supply 50/60 Hz 230 V AC Max. current requirement of auxiliary supply 50/60 Hz 400 V 3 AC Cooling air requirement Sound pressure level LpA Measuring surface level Ls Cable cross-sections, line-side, max. connectable per phase Cable cross-sections, motor-side, max. connectable per phase PE connection, max. connection cross-section at enclosure with M12 screw Degree of protection Width Height Depth Weight
0.85 < 85 17 1 95 1 3/0 AWG 2 95 2 3/0 AWG 1 50 1 1/0 AWG IP44 900 2200 1200 1000
0.36 < 85 17 4 240 4 500 MCM 4 185 4 350 MCM 2 240 2 500 MCM IP23 600 2200 1200 450
0.36 < 85 16 4 240 4 500 MCM 4 185 4 350 MCM 2 240 2 500 MCM IP23 600 2200 600 (compact) 450
0.67 < 87 17 6 240 6 500 MCM 8 185 8 350 MCM 3 240 3 500 MCM IP23 600 2200 1200 550
AWG/MCM 1 350 MCM (NEC, CEC) IP23 mm mm mm kg 1200 2200 600 420
Siemens D 12 2006
6/9
Accessories
SINAMICS GM150/SINAMICS SM150
STARTER drive/commissioning software
Overview
In addition, the following functions are available for optimization purposes: self-optimization trace (depending on drive) Diagnostics functions provide information about: control/status words parameter status operating conditions communication states Performance Easy to use: only a small number of settings need to be made for successful first commissioning: axis turning. Solution-based dialog-based user guidance simplifies commissioning. Self-optimization functions reduce manual effort for optimization. The built-in trace function provides optimum support during commissioning, optimization and troubleshooting. Minimum hardware and software requirements PG or PC with Pentium II 400 MHz (Windows 2000) Pentium III 500 MHz (Windows XP) 256 MB RAM (512 MB recommended) Monitor resolution 1024 768 pixels Windows 2000 SP3, XP Professional SP1 Microsoft Internet Explorer 5.01
The easy-to-use STARTER drive/commissioning software can be used for commissioning, optimization and diagnostics.
This software can be operated either as a standalone PC application or can be integrated into the SCOUT engineering system (on SIMOTION) or STEP 7 (with Drive ES Basic). The basic functions and handling are the same in both cases. In addition to the SINAMICS drives, the current version of STARTER also supports MICROMASTER 4 drives and frequency converters for the centralized SIMATIC ET 200S FC. The project wizards can be used to create the drives within the structure of the project tree. First-time users are supported by a solution-based dialog menu, with a standard graphics-based display maximizing clarity when setting the drive parameters. First commissioning is guided by wizards, which make all the basic settings in the drive. This enables a drive to be up and running after only setting a small number of parameters within the drive configuration process. The individual settings required are made using graphics-based parameterization screen forms, which also display the mode of operation. Examples of individual settings that can be made include: terminals bus interface setpoint channel (e.g. fixed setpoints) speed control (e.g. ramp-function generator, limits) BICO interconnections diagnostics Experts can gain rapid access to the individual parameters via the expert list and do not have to navigate dialogs.
Integration
For the communication between PG/PC and a Control Unit a PROFIBUS Communication Module and a connection cable are required. E.g. PROFIBUS Communication Module CP 5512 (PCMCIA card type 2 + adapter with 9-pole SUB-D socket for connection to PROFIBUS). For MS Windows 2000/XP Professional and PCMCIA 32) Order No.: 6GK1551-2AA00 and connection cable between CP 5512 and PROFIBUS Order No.: 6ES7901-4BD00-0XA0 For MICROMASTER 4, SINAMICS G110 and SINAMICS G120 PC converter connection sets are available for a safe point-topoint connection to the PC. Order No. for MICROMASTER 4: 6SE6400-1PC00-0AA0 (the scope of supply includes a 9-pole SUB-D connector and an RS 232 standard cable, 3 m) Order No. for SINAMICS G110 and SINAMICS G120: 6SL3255-0AA00-2AA0 (the scope of delivery includes a 9-pole SUB-D connector and a RS 232 standard cable, 3 m, and the STARTER commissioning tool on CD-ROM)
6/10
Siemens D 12 2006
Accessories
SINAMICS GM150/SINAMICS SM150
Drive ES engineering system
Overview
Communication
Drive ES SIMATIC
Description Drive ES Basic V 5.4 Configuration software for the integration of drives into Totally Integrated Automation Requirement: STEP 7 V5.3 and higher, SP3 Supply format: on CD-ROM Ger., Eng., Fr., Sp., It. with electronic documentation Single-user license Multi-user license, 60 pieces Update service for single-user license Update service for multi-user license Upgrade from V 5.x to V 5.4 Drive ES SIMATIC V 5.4 Function block library for SIMATIC for the parameterization of communication with the drives Requirement: STEP 7 V5.3 and higher, SP3 Supply format: on CD-ROM Ger., Eng., Fr., Sp., It. with electronic documentation Single-user license incl. 1 x runtime license Runtime license Update service for single-user license Upgrade from V 5.x to V 5.4 Drive ES PCS 7 V 6.1 Function block library for PCS 7 for the integration of drives Requirement: PCS 7 V 6.1 and higher Supply format: on CD-ROM Ger., Eng., Fr., Sp., It. with electronic documentation Single-user license incl. 1 x runtime license Runtime license Update service for single-user license Upgrade from V 5.x to V 6.1
Order No.
G_D212_en_00070
Drive ES is the engineering system used to integrate Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively in terms of communication, configuration and data management. The STEP 7 Manager user interface provides the basis for this procedure. Various software packages are available for SINAMICS: Drive ES Basic for first-time users of the world of Totally Integrated Automation and the option for routing beyond network limits and the use of the SIMATIC teleservice. Drive ES Basic is the basic software program for setting the parameters of all drives online and offline. Drive ES Basic enables both the automation system and drives to be handled via the SIMATIC Manager user interface. Drive ES Basic is the starting point for common data archiving for complete projects and for extending the use of the SIMATIC teleservice to drives. Drive ES Basic provides the configuration tools for the new Motion Control functions slaveto-slave communication, equidistance and isochronous operation with PROFIBUS DP. Drive ES SIMATIC simple parameterization of the STEP 7 communication instead of programming. In order to use Drive ES SIMATIC, STEP 7 must be installed. It features a SIMATIC function block library, making the programming of the PROFIBUS interface in the SIMATIC CPU for the drives easy and secure. There is no need for separate, time-consuming programming of the data exchange between the SIMATIC CPU and the drive. All Drive ES users need to remember is: Copy Modify Download Ready. Customized, fully-developed function blocks are copied from the library into user-specific projects. Frequently-used functions are set to run in program format: - Read out complete diagnostics buffer automatically from the drive - Download complete parameter set automatically from the SIMATIC CPU to the drive e.g. in the event of a device being replaced. - Load part parameter sets (e.g. recipe and product replacement) automatically from the SIMATIC CPU - Read back, i.e. update, complete parameterization or part parameter sets from the drive to the SIMATIC CPU. Drive ES PCS 7 integrates drives with the PROFIBUS interface into the SIMATIC PCS 7 process control system. Drive ES PCS 7 can only be used with SIMATIC PCS 7 Version 5.0 and higher. Drive ES PCS 7 provides a function block library with function blocks for the drives and the corresponding faceplates for the operator station, which enables the drives to be operated from the PCS 7 process control system. For further information please visit us on the Internet at: http://www.siemens.com/drivesolutions
Siemens D 12 2006
6/11
Accessories
SINAMICS GM150/SINAMICS SM150
SIMOTION SCOUT engineering software
Overview
While the SIMOTION Motion Control system provides a wide variety of preprogrammed functions, you can also parameterize and program it for customized use. High performance tools, which provide optimum support and ease of use for the necessary engineering steps, are required for this. The SIMOTION SCOUT engineering system is the basis for uniform automation in mechanical engineering with SIMOTION and is integrated into the SIMATIC environment in accordance with TIA. SIMOTION SCOUT provides an integrated, function-oriented view of your automation task, combined with a high level of user friendliness. The possible SIMOTION applications range from a simple, parameterizable, speed-controlled single axis through to complex, mechatronically-coupled and programmable multi-axes machines. Therefore, SIMOTION SCOUT provides views adapted to the task and can be expanded with additional tools (e.g. tool for the graphic creation of cams). SIMOTION SCOUT is the engineering system for SIMOTION integrated in STEP 7 and provides all the required tools for configuration parameterization programming testing and diagnostics. Tasks such as the creation of the hardware and network configuration and the creation, configuration and parameterization of technological objects such as - axes - probes - cams - cam tracks - cam disks, etc. are graphically supported with operator prompting. The following programming languages are available for programming a SIMOTION application: ST (Structured Text in accordance with IEC 61131) textual high-level language LADs (Ladder Diagrams) and FBDs (Function Block Diagrams) MCC (Motion Chart Control) The integrated test and diagnostics functions are useful when commissioning and servicing. System requirements Software SIMOTION SCOUT - Windows NT4 SP6 or - Windows 2000 SP3 or - Windows XP Professional SP2 - SIMATIC STEP 7 V5.2 SP1 or SIMATIC STEP 7 V5.3 SP1/SP2/SP3 (with SIMOTION SCOUT stand-alone STEP 7 is not required as installation condition) - Optional: Drive ES Basic V5.3 SP1 is necessary if SIMODRIVE 611 universal or MASTERDRIVES MC is to be integrated in the project data management Hardware Minimum system requirements for PG/PC for SIMOTION SCOUT Hardware requirements for - Windows NT4 and Windows 2000, Pentium II 400 MHz/512 MB and higher - Windows XP Professional, Pentium III 500 MHz/512 MB and higher Main memory configuration 512 MB for: - PG/PC - SIMOTION P350 Min. screen resolution: 600 x 800 pixels Free hard disk storage: 790 MB, 1 GB for SIMOTION SCOUT stand-alone
6AU1810-1BA32-0XE0
6AU1810-1CA32-0XA0
6AU1810-1CA32-0XE0
6AU1810-0BA00-0XL0
Further information
A number of additional software products can be used in connection with SIMOTION SCOUT environment. It must be ensured that the corresponding versions of these software products are compatible. Compatibility lists are available under http://support.automation.siemens.com/WW/view/de/18857317
6/12
Siemens D 12 2006
Configuration
7
7/2 7/3 7/3 7/5 7/6 7/6 7/6 7/6 7/6 SIZER configuration tool Overview of interfaces Overview of connections Terminal block on TM31 Terminal block on TM15 Terminal block on isolation amplifier Temperature monitoring with PT100 evaluation unit Incorporation of an externally forced stop Incorporation of an externally arranged EMERGENCY STOP button Control of circuit-breaker on input side Checkbacks from the circuitbreaker on input side OFF command to superordinate circuit-breaker Connection of the auxiliary voltage supply Connection of the cooling unit Cooling unit Circuit-breakers Transformers Power cables Motors Scope of delivery 7/7 7/7 7/7 7/7 7/7 7/8 7/10 7/10 7/12 7/13 7/14
Siemens D 12 2006
Configuration
SINAMICS GM150/SINAMICS SM150
SIZER configuration tool
Overview
The drive configuration is saved in a project. In the project, the components and functions used are displayed in a hierarchical tree structure. The project view supports the configuration of drive systems and the copying/inserting/modifying of already configured drives. The configuration process produces the following results: parts list of the components required technical data characteristics comments on line harmonic distortions location diagram and dimension drawings These results are displayed in a results tree and can be reused for documentation purposes. User support is provided by the technological online help menu, which provides the following information: detailed technical data information about the drive systems and their components decision-making criteria for the selection of components Minimum hardware and software requirements PG or PC with Pentium II 400 MHz (Windows 2000) Pentium III 500 MHz (Windows XP) 256 MB RAM (512 MB recommended) At least 665 MB of free hard disk space An additional 100 MB of free hard disk space on Windows system drive Monitor resolution 1024 768 pixels Windows 2000 SP2, XP Professional SP1, XP Home Edition SP1 Microsoft Internet Explorer 5.5 SP2
The SIZER configuration tool provides an easy-to-use means of configuring the SINAMICS and MICROMASTER 4 drive families, as well as the SINUMERIK solution line CNC control. It provides technical support when sizing the hardware and firmware components required for a drive task. SIZER supports the complete configuration of the drive system, from simple individual drives to complex multi-axis applications. SIZER supports all configuration stages in one workflow: selection of the line supply motor design as a result of load configuration calculation of the drive components selection of the required accessories selection of the line-side and motor-side power options When SIZER was being designed, particular importance was placed on high usability and a universal, function-based approach to the drive task. The extensive user guidance makes using the tool easy. Status information keeps you continually informed about the progress of the configuration process. The SIZER user interface is available in German and English.
on request
7/2
Siemens D 12 2006
Configuration
SINAMICS GM150/SINAMICS SM150
Overview of interfaces
SINAMICS GM150
CB
1U2
1V2
ASM
I> I>>
1W2
ON
OFF
<U L-
Circuit-breaker OFF externally checkback =.EF-X22 17 A =.LA-X11 11 OFF command to superordinate circuit-breaker 12 13 Auxiliary supply 400 V 3 AC =.EA-Q11: 1 3 5 Auxiliary supply 230 V 1 AC =.EB-X1: 1 2 External forced stop External safety circuit 19A (=.EF-X21:) 19A (=.EF-X22:) External safety circuit 20A (=.EF-X21:) 20A (=.EF-X22:)
L1 L2 L3
L1 N
Incorporation of an externally arranged EMERGENCY STOP button =.LA-X51: EMERGENCY STOP on 1A converter 2A OFF command to circuit-breaker Options N30 to N33 Controlled outgoing feeder for auxiliaries 400 V 3 AC =.GC-X1: 1 2 3 4 5 6 Auxiliaries ON checkback =.GC-X2: 1 2 Options N35 to N38 Controlled outgoing feeder for auxiliaries 230 V 1 AC =.GC-X1: 7 8
L1 N
L1 N
M 3~ 230 V 1 AC (control)
L N PE
Siemens D 12 2006
7/3
G_D012_EN_00036
Note: This is an overview connection diagram. For detailed plant configuration, see interface diagrams.
9 10 External supply ON circuit-breaker =.GC-X2: 3 4 Option L50 Cabinet lighting and service socket outlet in control section =.EG-X1: 1 2 L1 L2 L3 PE
Cooling unit (water-cooled version) Auxiliary supply 400 V 3 AC / 230 V 1 AC -X1 1 2 3 PE -X3 1 2 3 400 V 3 AC (coolant pumps)
Configuration
SINAMICS GM150/SINAMICS SM150
Overview of interfaces
Synchronisation
SINAMICS SM150
1U2
1V2
ASM
1W1 L+ =.LA-X52 Speed measurement 1A ON command SMC30 2A to circuit-breaker 3A ON command 4A to circuit-breaker 7A OFF command 9A to circuit-breaker =.LD-A11: 11A Tripping of undervoltage coil 1T1 1T2 12A of circuit-breaker 1T3 13A OFF command to the second OFF coil 2T1 15A of the circuit-breaker 2T2 =.LA-X11 2T3 1A Circuit-breaker ready 3T1 to start checkback 3T2 2A Circuit-breaker OFF checkback 3T3 3A 4A Circuit-breaker ON checkback =.HC-A31 X520: 2 3 4 5 6 7 8 9 X521: 2 3 4 5 6 7 8 9 X522: 2 3 4 5 6 7 8 9 =.EF-X21 8 =.EF-X22 8
1W2
ON
OFF
<U L-
Circuit-breaker OFF externally checkback =.EF-X22 17A =.LA-X11 11 OFF command to superordinate circuit-breaker 12 13 Auxiliary supply 400 V 3 AC =.EA-Q11: 1 3 5 Auxiliary supply 230 V 1 AC =.EB-X1: 1 2 External forced stop External safety circuit 19A (=.EF-X21:) 19A (=.EF-X22:) External safety circuit 20A (=.EF-X21:) 20A (=.EF-X22:)
L1 L2 L3
L1 N
Incorporation of an externally arranged EMERGENCY STOP button =.LA-X51: EMERGENCY STOP on 1A converter 2A OFF command to circuit-breaker Options N30 to N33 Controlled outgoing feeder for auxiliaries 400 V 3 AC =.GC-X1: 1 2 3 4 5 6 Auxiliaries ON checkback =.GC-X2: 1 2 Options N35 to N38 Controlled outgoing feeder for auxiliaries 230 V 1 AC =.GC-X1: 7 8
L1 N
9 10 External supply ON circuit-breaker =.GC-X2: 3 4 Option L50 Cabinet lighting and service socket outlet in control section =.EG-X1: 1 2
L1 N
L N PE
-X3 1 2 3
230 V 1 AC (control)
7/4
Siemens D 12 2006
G_D012_EN_00035
Note: This is an overview connection diagram. For detailed plant configuration, see interface diagrams.
L1 L2 L3 PE
Cooling unit Auxiliary supply 400 V 3 AC / 230 V 1 AC -X1 400 V 3 AC (coolant pumps) 1 2 M 3 3~ PE
Configuration
SINAMICS GM150/SINAMICS SM150
Overview of interfaces
Configuration
The interfaces of the TM31 and TM15 Terminal Modules are available for communication with the superordinate control level. In addition, further terminal blocks can be used to connect the circuit-breaker or external protection and monitoring devices. The following tables give an overview of the type and preassignment of the interfaces in the standard version. Note: For max. conductor cross-section and further technical data on TM31 and TM15 Terminal Modules, see description of options G61 and G63.
Terminal block on TM31 (=.HCA51) Terminal X540: 1-8 X520: 1 DI0 Digital input Preas electrically isolated signed with optocoupler internally Preas signed internally Reference ground for digital inputs DI0 to DI3 Reference ground for P24, auxiliary voltage for digital inputs 5 6 7 8 X522: 1 2 3 4 5 6 DI4 Digital input Preas electrically isolated signed with optocoupler internally Reference ground for digital inputs DI4 to DI7 Reference ground for P24, auxiliary voltage for digital inputs 24 V DC supply for inputs/outputs DI/O8 to DI/DO11 Digital inputs/ digital outputs non-isolated X542: 1 2 3 DO 0.NC DO 0.COM DO 0.NO Relay output for changeover contact Max. switching voltage: 250 V AC, 30 V DC Max. switching power at 250 V AC: 2000 VA Max. switching power at 30 V DC: 240 W Relay output for changeover contact Max. switching voltage: 250 V AC, 30 V DC Max. switching power at 250 V AC: 2000 VA Max. switching power at 30 V DC: 240 W NC contact Basic NO contact 7 8 KTY+ KTYTemperature sensor KTY84 0 C to 200 C or PTC (Rcold < 1.5 kOhm) AO 1V+ AO 1VAO 1C+ AO 0V+ AO 0VAO 0C+ Analog outputs for the following ranges: 10 V to +10 V +4 mA to +20 mA 0 mA to +20 mA 20 mA to +20 mA Main actual setpoint (speed) Isolation amplifiers are used here for voltage isolation (4 mA to 20 mA, 0 V to 10 V, 0 mA to 20 mA) Isolation amplifiers are used here for voltage isolation (4 mA to 20 mA, 0 V to 10 V, 0 mA to 20 mA) The sensor type must be parameterized. P10 M N10 M Auxiliary voltage 10 V (10 mA) for connection of a potentiometer for setpoint input with an analog input P24 24 V DC supply for inputs DI0 to DI7 Type Preassignment Comment 3 4 AI1+ AI1Terminal block on TM31 (=.HCA51) Terminal X521: 1 2 AI0+ AI0Analog inputs set up as differential inputs for the following ranges: 10 V to +10 V +4 mA to +20 mA 0 mA to +20 mA 20 mA to +20 mA The voltage input/current input is selected with a switch Main setpoint speed Isolation amplifiers are used here for voltage isolation (4 mA to 20 mA, 0 V to 10 V, 0 mA to 20 mA) Isolation amplifiers are used here for voltage isolation (4 mA to 20 mA, 0 V to 10 V, 0 mA to 20 mA) Type Preassignment Comment
DI1
3 4 5
DI2 DI3 M1
X530: 1
2 3 4 5
X541: 1 P24
DI/DO8
4 5 6
3 4 5 6
DI/DO9 DI/DO10 DI/DO11 M Reference ground for P24, ground of digital inputs/ digital outputs
Siemens D 12 2006
7/5
Configuration
SINAMICS GM150/SINAMICS SM150
Overview of interfaces
Configuration (continued)
Terminal block on TM15 (=.HCA31) Terminal Type X520: 2 3 4 5 6 7 8 9 X521: 2 3 DI/DO8 DI/DO9 Bidirectional digital inputs/outputs 1) Control bit 2 command (setpoint lower) Control bit 3 command (selection fixed setpoint bit 0) Control bit 4 command (selection fixed setpoint bit 1) Switching to remote operation Switching of direction Ready to start message Ready to operate message Operation message Converter fault message Converter alarm message Local/remote operation state message Drive rotates right message (clockwise) Free Free Free Free The jumper must be replaced according to the control mode (non-isolated/isolated). The jumper must be replaced according to the control mode (non-isolated/isolated). Incorporation of an externally forced stop 1) Terminal 19A 19A 20A 20A Button (NC contact) Type Button (NC contact) Comment External safety circuit: OFF command to the circuitbreaker External safety circuit: Tripping of circuit-breaker =.EFX21/=.EFX22: DI/DO0 DI/DO1 DI/DO2 DI/DO3 DI/DO4 DI/DO5 DI/DO6 DI/DO7 Bidirectional digital inputs/outputs1) ON OUT1 OUT2 OUT3 Acknowledgement Switching to local operation Inverter release Control bit 1 command (setpoint higher) Preassignment Terminal block on isolation amplifier Terminal =.LCA21: 1 2 =.LCA22: 1 2 =.LCA41: 1 2 =.LCA42: 1 2 Additional actual value speed (4 mA to 20 mA) Signal level adjustable (0 V to 10 V; 0 mA to 20 mA; 4 mA to 20 mA) Main actual value speed (4 mA to 20 mA) Signal level adjustable (0 V to 10 V; 0 mA to 20 mA; 4 mA to 20 mA) Additional setpoint speed Signal level adjustable (4 mA to 20 mA) (0 V to 10 V; 0 mA to 20 mA; 4 mA to 20 mA) Main setpoint speed (4 mA to 20 mA) Signal level adjustable (0 V to 10 V; 0 mA to 20 mA; 4 mA to 20 mA) Preassignment Comment
Temperature monitoring with PT100 evaluation unit Terminal =.LDA11: 1T1 to 1T3 PT100 2T1 to 2T3 PT100 3T1 to 3T3 PT100 Sensor 1 Sensor 2 Sensor 3 Type Comment
DI/DO10
5 6 7 8
DI/DO11 DI/DO12 DI/DO13 DI/DO14 DI/DO15 DI/DO16 Bidirectional digital inputs/outputs 1) DI/DO17 DI/DO18 DI/DO19 DI/DO20 DI/DO21 DI/DO22 DI/DO23 P24
9 X522: 2 3 4 5 6 7 8 9 =.EFX21: 8
The sensors can be connected to the PT100 evaluation unit using both a two-wire or three-wire system. In the two-wire system, inputs xT1 and xT2 must be assigned and terminals xT2 and xT3 must be jumpered. The limit values for alarm and shutdown must be set centrally for all three sensors. The output relays are integrated into the internal fault and shutdown sequence of the converter. The signals can also be picked up on the plant side with two spare fault signaling relays.
1) The jumpers must be replaced according to the control mode (non-isolated/isolated). Incorporation of an externally arranged EMERGENCY STOP button Terminal Type Button (NC contact) Comment EMERGENCY STOP on converter =.LAX51: 1A 2A
=.EFX22: 8 M
1) The digital inputs/outputs can be parameterized individually as inputs or outputs (isolation in three groups of eight channels each). The preassignment as an input or output is identified by underlining.
7/6
Siemens D 12 2006
Configuration
SINAMICS GM150/SINAMICS SM150
Overview of interfaces
Configuration (continued)
Control of circuit-breaker on input side Terminal =.LAX52: 1A 2A 3A 4A 7A 9A 11A 12A 13A 15A Isolated contact Isolated contact Tripping of undervoltage coil of circuit-breaker OFF command to the second OFF coil of the circuit-breaker Isolated contact OFF command to circuit-breaker Isolated contact ON command to circuit-breaker Isolated contact ON command to circuit-breaker Type Comment
Connection of auxiliary voltage 50 Hz 230 V 1 AC or 60 Hz 120 V 1 AC Terminal =.EBX1: 1 2 L1 N E.g. controller and closed-loop control, protection and monitoring unit Type Comment
Checkbacks from the circuit-breaker on input side Terminal =.LAX11: 1A 2A 3A 4A Digital input Digital input Digital input Digital input Circuit-breaker ready to start checkback Circuit-breaker OFF checkback Circuit-breaker ON checkback Circuit-breaker OFF externally checkback Type Comment
OFF command to superordinate circuit-breaker Terminal =.LAX11: 11 12 13 Relay output for changeover contact Basic Type Comment
Admissible contact load NO contact DC-13 in acc. with NC contact DIN EN 60947-5-1/ VDE 0660-200 (IEC 60947-5-1): 24 V/10 A
Siemens D 12 2006
7/7
Configuration
SINAMICS GM150/SINAMICS SM150
Cooling unit
Overview
The cooling unit is used to dissipate the power loss from the converter. It consists of an inner deionized water circuit and an outer raw-water circuit.
Requirements to be met by the cooling water in the deionized water circuit The deionized water circuit must be filled and re-filled with cleaned water for batteries (distilled or demineralized water).
Deionized water Specific conductivity when filled in Evaporation residue pH value in acc. with EN 60993 (IEC 60993) 30 mS/cm 1) < 20 mg/l 5 to 9
Mode of operation
The heated deionized water in the inner circuit of the converter passes through two redundantly operating, maintenance-free circulating water pumps into the water/water plate-type heat exchanger which is made of stainless steel and connected to the raw-water circuit on the plant side. The deionized water is cooled by the raw-water of the outer circuit and flows back into the converter. The closed inner deionized water circuit is filled with deionized water and vented with a compensator. This vessel is located at the highest point of the cooling circuit.
Function
Requirements to be met by the raw-water The raw-water must be chemically neutral, clean and free of solids. Other quality requirements to be met by the raw-water are listed in the following table.
Raw-water Grain size of any entrained parts pH value Carbonate hardness Total hardness Chlorides Sulfates Nitrates Iron (Fe) Ammoniac Dissolved substances < 0.5 mm 6.5 to 8.0 < 0.9 mMol/l (5 dH) < 1.7 mMol/l (9.5 dH) 60 mg/l 80 mg/l 10 mg/l 0.2 mg/l 10 mg/l < 3.4 mMol/l (340 ppm)
Content of not detectable metals from the hydrogen sulfide group (lead, antimony, tin, bismuth, arsenic, copper, cadmium) metals from the ammonium sulfide group (iron, cobalt, nickel, chrome, manganese) sulfur and nitrogen chloride compounds Content of oxidizable, organic substances no more than a quantity equivalent to the consumption of 30 mg/l potassium permanganate KMnO4
Monitoring units in the deionized water circuit To guarantee the self-protection of the converter, the deionized water is monitored by the converter: Conductivity measurement: The conductivity of the cooling water is constantly monitored in order to ensure that the leakage currents in the converter between different voltage levels and with respect to ground remain low. An ion exchanger (in the cooling unit) holds the conductivity below the permitted maximum value of 1.0 mS/cm. If the conductivity is too high, the ion exchanger filling must be changed. After the first year, an ion exchanger filling must be changed at least every two years as a rule. Temperature monitoring Flow monitoring Further monitoring operations and the control of the electrical equipment are performed in the cooling unit: A compensator for the compensation of changes in the volume of cooling water due to evaporation or temperature changes Pressure display in the converter water intake The operating status is signaled to the converter. Avoidance of condensation To avoid condensation at low raw-water temperatures, a threeway valve for controlling the water temperature is installed as standard. Redundancy (options W02, W12) On request, the cooling unit can be designed for fully redundant operation, i.e. two plate-type heat exchangers are provided. In this case, defective parts can be exchanged while the system continues to run. Tubular heat exchanger (on request) If, contrary to the standard water quality values listed above, the raw-water contains suspended matter that might settle in the heat exchanger at slow flow velocities, then a tubular heat exchanger must be used. This and the actual quality of the raw-water must be specified when placing the order.
In case of deviations it is recommended to carry out an analysis of the water in order to ensure the heat exchangers endurance strength. In case of aggressive cooling water (including sea water), plate-type heat exchangers made of titanium should be used (options W11, W12).
1) After the converter is filled and switched on, the conductivity value is reduced to the permitted operating value of < 1.0 mS/cm by the ion exchanger which is integrated in the cooling unit.
7/8
Siemens D 12 2006
Configuration
SINAMICS GM150/SINAMICS SM150
Cooling unit
Function (continued)
External air-water-heat exchanger (on request) If no process water is available on the plant side, an external airwater-heat exchanger can be used on request. In this case the ambient temperature must not exceed 35 C. Chiller (on request) If no process water is available on the plant side and the ambient temperature is higher than 35 C, a so called chiller (incl. compressor) can be used on request. Specification for cooling unit (on request) If option W14 (converter without cooling unit) is selected, a specification for the cooling unit is available on request. Flowchart of the cooling unit
Level switch
LA LSD
Shut-off valve
Ball valve
Reducing valve
Temperature control
PT 100
Ball valve
Fine filter
Three-way valve Ion exchanger Reducing valve Ball valve Non-return valve Shut-off valve
Ball valve
Converter connection
Shut-off valve
Pump
M
Heat exchanger
Shut-off valve
Deionized water from converter Ball valve Shut-off valve Non-return valve Shut-off valve
G_D012_EN_00034
Technical data
Technical data of the cooling unit Degree of protection Cabinet All internal components Supply voltage Raw-water circuit Inlet temperature min. +5 C max. +35 C (with power reduction of the converter max. +40 C) max. 10 K (with minimum flow) min. 2 bar max. 10 bar min. 2.7 bar nominal 3.0 bar max. 3.3 bar IP20 IP54 3/N/PE/400 V AC 10%, 50/60 Hz 3%
Siemens D 12 2006
7/9
Configuration
SINAMICS GM150/SINAMICS SM150
Circuit-breakers Transformers
Configuration
The circuit-breaker connected on the primary side of the incoming transformer on the plant side is part of the converter safety system. If a fault occurs inside the converter, the energy discharged at the fault location must be limited. This is realized as a result of the inductance of the incoming transformer which limits the rate-of-rise and the circuit-breaker trips as quickly as possible. In order to guarantee these conditions, the circuit-breaker must have the following features: The complete release time of the circuit-breaker must not exceed 80 ms. The circuit-breaker must be equipped with an undervoltage release. The undervoltage release (undervoltage coil) is controlled through the release circuit into which also the undervoltage release output of the converter must be integrated. It is supplied with the auxiliary voltage (safe supply) of the switchgear. Additional delay times in controlling the circuit-breaker must be avoided. All commands from the converter to the circuitbreaker must act directly, without any coupling relays involved. A separate checkback signal must exist for each of the circuitbreaker states ON and OFF. The checkbacks must not be delayed, i.e. no coupling relays may be used. An additional, independently operating overcurrent protection of the circuit-breaker must be provided on the plant side. Under no circumstances may the circuit-breaker be switched on externally, by neither electrical nor mechanical means. A mechanical interlock of the manual ON command on the circuit-breaker prevents destruction of the converter by uncoordinated switch-on.
Configuration
The SINAMICS GM150 and SINAMICS SM150 converters are always connected to the medium-voltage system through a converter transformer. When the transformer is implemented, the drive (converter and motor) is decoupled and electrically isolated from the mains supply: the short-circuit power is reduced to a value smaller than max. permissible converter and motor are operated ground-free the line harmonic distortions and the voltage ripple are limited A ground-fault monitor integrated in the converter monitors the insulation resistance against ground. SINAMICS GM150 For the 12-pulse Basic Line Module of the SINAMICS GM150 converter, a three-winding transformer is required. The secondary windings of the three-winding transformer have a phase shift around 30el, resulting in a 12-pulse infeed with accordingly lower line harmonic distortions. For the 24-pulse Basic Line Module, two three-winding transformers are required. Through additional shifting of the primaryside windings of the two transformers around +7.5 and 7.5 respectively it is possible to configure a 24-pulse infeed. Instead of the two three-winding transformers a five-winding transformer can also be used in consultation with the transformer manufacturer.
7/10
Siemens D 12 2006
Configuration
SINAMICS GM150/SINAMICS SM150
Transformers
Configuration
The following characteristics must be taken into account for the configuration: Short-circuit voltage: - uk 8% for SINAMICS GM150 in IGBT version - uk 10% for SINAMICS GM150 in IGCT version (related to 10 MVA) Tappings for voltage adjustments: 2 2.5% or 5% for operation with a sine-wave filter (the winding tappings are usually located on the primary side of the transformer) The voltages and insulation of the secondary-side windings must be configured according to the following table:
SINAMICS GM150 IGBT version, basic circuit and SINAMICS GM150 IGCT version Circuit Basic circuit SINAMICS GM150 IGBT version Parallel connection of Basic Line Module and Motor Module on common DC bus 24-pulse
%, .
SINAMICS SM150 A two-winding transformer is required for each Active Line Module. In the case of a parallel connection of two complete converter units it is also possible to use a three-winding transformer with shifted windings for the suppression of line harmonics. The following characteristics must be taken into account for the configuration: Transformer secondary voltage: 3.3 kV Leakage inductance: 1 mH (this value includes all inductances between network and converter: network short-circuit inductance, transformer inductance, reactor inductance. Short-circuit voltage uk = 15 to 28% depending on the transformer power) Tappings for voltage adjustments: 2 2.5% (the winding tappings are normally located on the high voltage side of the transformer) The transformer must be designed for the following loads: max. dv/dt load on the converter input terminals: 6 kV/ms peak voltage load phase-phase and phase-ground: 8.4 kV current load with direct component: approx. 4 A to 5 A
Infeed
12-pulse
24-pulse
&, ( 1)
2 threewinding transformers
Dy5 Dd0
Dy5 Dd0 with shifting +7.5 Dy5 Dd0 with shifting 7.5
7
Parallel connection for power increase
Basic circuit
kV 2 0.6 (2x) 2 0.85 (2) 2 1.1 (2) 2 1.55 (2) 2 1.7 (2)
1) With 6.0 and 6.6 converters the configuration of the Basic Line Modules for parallel connection corresponds to the configuration of the 24-pulse basic circuit.
2) The specified voltages are the (impulse withstand) test voltages necessary for the transformer secondary windings against ground. As the transformers generally have temperature evaluations in the windings, the specified test voltages are necessary for reinforced insulation. If no control circuits are integrated in the windings, test voltages according to the basic insulation are adequate. Siemens D 12 2006
7/11
Configuration
SINAMICS GM150/SINAMICS SM150
Power cables
Configuration
If the SINAMICS GM150 and SINAMICS SM150 converters are operated without sine-wave filters, higher voltages arise on the motor terminals and therefore on the cable due to the switching edges. Therefore, suitable cables must be selected to meet the EMC and voltage endurance requirements. Different technical characteristics result in differences between the converters with IGBT power sections and those with IGCT power sections. Motor cables The correct cable cross-section depends not only on the motor current but also on the number of cables which are routed in parallel, the routing conditions and the ambient temperature. It must be determined for each individual case. Local installation regulations must be observed in addition. For extensive systems it is recommended to install a cable for equipotential bonding in addition to the power cables. Local regulations must be observed in this case too. SINAMICS GM150 in IGBT version (without sine-wave filter) The cables from the converter to the motor must be designed as shielded, three-wire medium-voltage cables for 3.6/6 kV (in the case of 2.3, 3.3 and 4.16 kV converters) or for 6.6/10 kV (in the case of 6.0 and 6.6 kV converters). Symmetrical cables with individually shielded copper conductors are recommended. An additional shared outer shield is an advantage for improving the EMC characteristics. The cables must have a cable capacity of a maximum 0.5 mF/km with a diameter of 185 mm2 (typically 0.4 mF/km). Single-wire cables (also shielded versions) are not recommendable for EMC reasons. Using more than three parallel cables per phase is not permitted. SINAMICS GM150 in IGBT version (with sine-wave filter) For operation with a sine-wave filter there are no special requirements to be met by the cables from the converter to the motor. Unshielded standard medium-voltage cables can be used. The voltage class of the cables must be selected in accordance with the voltage applied to the motor. SINAMICS GM150 in IGCT version and SINAMICS SM150 The cables from the converter to the motor must be designed as shielded medium-voltage cables for 3.6/6 kV. Symmetrical threewire cables with individually shielded copper conductors are recommended. An additional outer shield is an advantage for improving the EMC characteristics. Single-wire cables (also shielded versions) are permitted if three-wire, symmetrically arranged cable bundles with one cable from each phase are formed (three-phase current systems). Preferably four cables per phase are installed (but at least two cables per phase). Cables between transformer and converter The same considerations apply as in the case of the motor cables. Permissible cable lengths In the case of long cables between the converter and the motor, reflection effects lead to overvoltages on the motor terminals and hence to a higher motor insulation stress. These charge/ discharge currents and with them the voltage stress can be limited by output reactors or sine-wave filters.
not permitted
1) Distance from converter to motor according to current load for max. 6 parallel three-wire EMC cables.
7/12
Siemens D 12 2006
Configuration
SINAMICS GM150/SINAMICS SM150
Motors
Configuration
Operation of Siemens high-voltage motors No sine-wave filter is required between the Siemens highvoltage motors H-compact, H-compact PLUS, H-modyn and special motors for e.g. marine, rolling mill and high-speed applications and the converters SINAMICS GM150 and SINAMICS SM150. Reliable operation of the drive is assured by the following measures: The MICALASTIC VPI insulation system is optimally suited for the voltage stressing which occurs in converter operation. No dangerous bearing currents occur as insulated bearings are used on the drive end and a shaft grounding device on the non-drive end. If a digital speed encoder (option) is used, the shaft grounding device is integrated there. In order to effectively protect the bearings of the driven load, we recommend that insulated couplings are used. For almost all other applications, insulated couplings are available as standard from coupling manufacturers. Minimum motor rated frequency: - SINAMICS GM150 in IGBT version: 20 Hz - SINAMICS GM150 in IGCT version, SINAMICS SM150: 8.5 Hz Operation of motors with several winding systems To increase the output rating of the converters it is possible to operate several power sections in parallel. In this way a maximum output rating of up to 10 MVA with an output voltage of 4.16 kV can be achieved with the SINAMICS GM150 in IGBT version with a double parallel connection. Using the same principle, a maximum power of 28 MVA is achieved with the SINAMICS GM150 in IGCT version and the SINAMICS SM150 in triple parallel operation. To ensure a uniform division of current between the two subsystems, two or three electrically isolated but mutually non-displaced winding systems are required in the motor. Operation of two-pole motors High-speed converter drives with 2-pole motors require special measures regarding their mechanical design (limiting and critical speed, bearings, rotor design, adaptation to the foundation). An inquiry is required for such applications. For Retrofit applications, the motors must not show mechanical self-resonant frequency. Affected speed ranges can be faded by the converter if necessary. Operation of explosion-proof motors Motors from Siemens are also available in versions for use in hazardous areas. Available types of protection are: Pressurized enclosure EEx pe IIC T3 in accordance with IEC and EN 60079-2 Non sparking EEx n AIIC T3 in accordance with IEC and EN 60079-15 Apart from the measures required also on fixed-speed motors to increase protection, on variable speed motors it is necessary in addition to configure the shaft grounding device with protection type EEx d IIC T6 (without rotary pulse encoder) or EEx de IIC T6 (with digital speed encoder). Please always inquire for motors with increased safety EEx e. Ex certification For motors with EEx n type of protection and converter operation it may be necessary in the individual case to subject the complete system to an acceptance test in order to issue an Ex certificate. An inquiry is required for such cases. No acceptance test of the complete system is required for motors with EEx pe type of protection and converter operation. Drives with square-law load torque Drives with a square-law load torque (M n2) such as for pumps and fans require the full torque at rated speed. Generally, increased starting torques or load surges do not occur. Thus, the converter does not have to be dimensioned for an overload condition. The following applies when selecting a suitable converter for drives with square-law load torques: The rated converter current must be at least as high as the motor current which flows at full torque at the required load operating point. Drives with constant load torque Self-ventilated motors cannot provide their full rated torque in continuous operation over the complete speed range. The continually permissible torque decreases with decreasing speed due to the reduced cooling effect. With self-ventilated motors, the torque and output must be reduced according to the specific speed control range. For forced-ventilated motors, depending on the speed control range, no or only a comparatively minor derating in torque, and hence in output, is necessary. For frequencies above the rated frequency fN, the motors are operated in the field weakening range. The usable torque decreases in this case with approx. fN/f, and the power remains constant. Thus, a margin of 30% to the stall torque must be observed, which decreases according to the function (fN/f)2. Drives with overload requirements The rated data of the converters specified in the technical data provide no reserves for overload capability. If requirements are imposed on an increased overload capability of the converters, a power reduction of the converters is always necessary. The size of the required power reduction differs according to the application, operation mode and converter type. The power reduction can be determined on request if all boundary conditions are stipulated. Operation of standard motors (only SINAMICS GM150 in IGBT version) In connection with the optional sine-wave filter (option Y15) the SINAMICS GM150 in IGBT version is ideal for the operation of standard motors in applications with a square-law load torque (e.g. pumps and fans). The near sine-wave output voltages and currents rule out all load of the insulation system and bearings. The voltage harmonic distortion at an output frequency of 50 Hz equals less than 5% with a sine-wave filter. It should be noted that only machines with a square-law reaction torque (fluid machines) can be operated and that operation in the field weakening range is not permitted. Possible nominal output frequencies (base frequencies) are limited to the range 30 Hz to max. 66 Hz. The frequency setting range is 1:10. For optimum adaptation of the sine-wave filter to the motor, the motor must include details of the motor rated current, the motor current in the working rated point and the motor no-load current.
Siemens D 12 2006
7/13
Configuration
SINAMICS GM150/SINAMICS SM150
Scope of delivery
Configuration
The standard scope of delivery of the SINAMICS GM150 and SINAMICS SM150 comprises: 1. Basic unit The basic unit consists of the converter power section incl. control, in either air-cooled or water-cooled version. One or more transport units are delivered depending on the converter type. Exact details are to be found in the dimension drawing for the specific order. 2. Cooling unit for water-cooled converters The cooling unit consists of one transport unit and is delivered without deionized water. In the case of the SINAMICS GM150 as IGBT version a connecting piece from the cooling unit to the converter is delivered as well. For the SINAMICS GM150 converter in IGCT version and the SINAMICS SM150 converter the piping from the cooling unit to the basic unit runs below the units. The necessary pipes and connection pieces are part of the scope of delivery and are delivered as loose supply. Special conditions of installation are not taken into account and, where applicable, require special inquiry (e.g. cooling unit not placed directly next to the basic unit). The piping to the raw-water supply on the plant side is not included. 3. Optional components Optional components, e.g. sine-wave filters or output reactors, are delivered as separate transport units. If necessary, cables for connecting the optional components to the power section are delivered as well. 4. Static excitation unit In case of converters that drive synchronous motors, usually a static excitation unit is part of the scope of delivery. It must be ordered with a separate order number (see chapter Accessories). The following items are not included in the standard scope of delivery: cables between transformer and converter, motor cables, circuit-breakers, transformer, motor, cable ducts, filter systems and piping for the raw-water supply of the cooling unit.
7/14
Siemens D 12 2006
8
8/2 8/2 8/3 8/4 8/6 8/6 8/7 8/7 8/8 Training Overview Design Description Training case AOP30 cabinet operator panel Documentation SPARESonWeb Online spare parts catalog Service & Support
Siemens D 12 2006
Overview
The right mixture: blended learning Blended learning is understood to be the combination of various training media and sequences. For example, a local attendance course in a training center can be optimally supplemented by a teach-yourself program as preparation or follow-up. Furthermore, SITRAIN utilizes supported online training for live instruction on the Internet at agreed times. The right mixture is the solution. Therefore blended learning can convey complex topics well, and train networked thinking. Additional effect: reduced traveling costs and periods of absence through training sequences independent of location and time. The international learning portal Additional information is available on the Internet under: http://www.siemens.com/sitrain All training facilities at a glance: search in the worldwide range of courses at leisure, call up all course dates online, utilize the daily updated display of vacant course spaces - and register directly. Or let us advise you personally: Training is decisive for your success SITRAIN Siemens Training for Automation and Industrial Solutions provides you with comprehensive support in solving your tasks. Training by the market leader in automation, plant installation and plant support enables you to make your decisions with certainty and full command. Especially where the optimum and efficient use of products and plants are concerned. You can eliminate deficiencies in existing plants, and exclude expensive faulty planning right from the beginning. All in all, this represents an enormous gain for your company: shortened commissioning times, optimized plant components, faster troubleshooting, reduced downtimes. In other words, increased profits and lower costs. Course office, Infoline Germany Phone: +49 (0)1805-23 56 11 Fax: +49 (0)1805-23 56 12 ... and request our latest training catalog on:
Description ITC Catalog (paper version) Dates and price list including CD-ROM SITRAINonCD on CD-ROM interactive course information system Language German German German/ English Order No. E86060-K6850-A101-B6 E86060-P6850-A101-D2 E86060-D6850-A100-C4-7400
E86060-K6899-A101-B5-7400
Top trainers Our trainers know their topics in practice, and possess comprehensive didactic experience. Course developers have a direct wire to product development, and directly pass on their knowledge to the trainers. Practical experience The practical experience of our trainers makes it possible for them to pass on theoretical matter in a plausible manner. But since it is known that all theory is drab, we attach great importance to practical exercises which can comprise up to half of the course time. You can therefore immediately implement your new knowledge in practice. We train you on state-of-the-art methodically/didactically designed training equipment. You feel absolutely certain when trained in this manner. Wide variety With a total of approx. 300 local attendance courses, we train the complete range of A&D products and a large portion of the system solutions from I&S. Telecourses, teach-yourself software and seminars presented on the Web supplement our classical range of courses. Close to our customers The distance is short. You can find us approx. 60 times in Germany, and worldwide in 62 countries. You wish to have individual training instead of one of our 300 courses? Our solution: we will provide a program tailored exactly to your personal requirements. Training can be carried out in our training centers or at your company.
8/2
Siemens D 12 2006
Design
SINAMICS GM150/SM150 courses Here you will find an overview of the training courses available for the SINAMICS GM150/SM150. The courses are modular in design and are intended for a variety of target groups as well as individual customer requirements. The system overview will acquaint decision makers and sales personnel with the system very quickly. The planning course provides all the information you need to size the drive system. The basic and follow-up courses are sure to provide all the technical knowledge service personnel will need for servicing/ commissioning Motion Control applications, communication and cabinet units. All modules contain as many practical exercises as possible, in order to enable intensive and direct training on the drive system and with the tools in small groups.
Title
Target group Decision makers, sales personnel Configuration engineers, project engineers Programmers Commissioning engineers, configuration engineers Service personnel
Duration
Course code
SINAMICS system overview SINAMICS GM150/SM150 configuration SINAMICS GM150/SM150 commissioning and service/ diagnostics SINAMICS communication
3 days
DR-SN-COM
Siemens D 12 2006
8/3
Design (continued)
SINAMICS GM150/SM150 learning path
DR-SN-UEB
2 days
SINAMICS communication
DR-SN-COM
3 days
Description
SINAMICS system overview (2 days) DR-SN-UEB Description/learning target This course has been specially designed for sales personnel and decision makers, who wish to attain a rapid overview of the SINAMICS drive concept and its position in the existing Siemens drive environment. SINAMICS GM150/SM150 configuration (4 days) DR-SNM-PRJ Description/learning target The course is appropriate for design engineers, configuration engineers and sales personnel who plan the SINAMICS GM150/ SM150. Training covers the fundamental physical relationships for the design of a drive system. Using the self-explanatory SIZER configuration tool, different applications of SINAMICS are calculated, and consolidated using exercises on PCs. Control functions are explained, and their associated conditions described. The various options for SINAMICS are also presented to permit derivation of their application. Target group Configuration engineers, project engineers, programmers Requirements Knowledge of drive and control technology Content SINAMICS system overview Physical fundamentals for drive calculation Configuration of the SINAMICS GM150/SM150 cabinet components and their explanation: lines, EMC, emergency stop, interfaces SIZER configuration tool with example exercises for various applications Technical documentation: catalogs, configuration, instruction manuals Open-loop and closed-loop control functions Simple commissioning using the AOP30 operator panel Transformer/reactor Cooling plant High-voltage motor Medium-voltage cable
The system overview is supplemented by an introduction to the fundamentals of motor and converter technology. The SIZER configuration tool and the STARTER commissioning tool are presented and explained using short exercises. Target group Decision makers and sales personnel Content SINAMICS system overview Position with respect to existing drive systems Fundamentals of converter engineering and motors SIZER configuration tool STARTER commissioning tool Simple commissioning of a drive Practical exercises using the training case
8/4
Siemens D 12 2006
G_D012_EN_00031
Description (continued)
SINAMICS GM150/SM150 commissioning and service/ diagnostics (5 days) DR-SNM-SI Description/learning target Technical information about planning, configuration, commissioning and troubleshooting is provided in this course. Following an introduction to the hardware and documentation of the drive system, detailed information is given about software functions, the parameter structure and function diagrams. Practical exercises on training equipment and the STARTER commissioning tool consolidate this knowledge. Target group Commissioning engineers, configuration engineers, service personnel Requirements Knowledge of drive and control technology Content Components of the converters - Rectifiers, DC link, inverter - Air/water cooling - Terminal Board/Terminal Module - Controller and closed-loop control - Control of IGBTs - Common power supply Exercises on the simulator - Operation via AOP - Initial commissioning steps/test mode - Parameterization of converter with STARTER commissioning tool - Upload/download functions, learning function - Setpoint channel Control of converter using PROFIBUS DP Basic principle of closed-loop control (transvector control) Circuit diagrams Spare parts/maintenance SINAMICS communication (3 days) DR-SN-COM Description/learning target The course is appropriate for programmers and service personnel who, as an extension to the DR-SNS-SI course, require further knowledge on the PROFIBUS and RS 232 communication interfaces for STARTER and AOP30, as well as I/O terminals. The focal point is PROFIBUS with the PROFIDrive V3 profile with routing, teleservice, and the functionalities associated with the equidistant bus cycle, isochronous mode with servo applications, and direct OP access. Also described are the libraries of DriveES SIMATIC for cyclic and acyclic data exchange. This knowledge is expanded by practical exercises using SINAMICS and SIMATIC S7 training cases with CPU 315-2 DP. Target group Commissioning engineers, configuration engineers, service personnel Content Overview of the PROFIBUS DP, RS 232-PPI, CAN and I/O terminals: function, topology, parameterization Fundamentals of PROFIBUS with the PROFIDrive V3 profile Basic functions on the PROFIBUS: routing, teleservice and direct access PROFIBUS for Motion Control with: equidistant bus cycle and isochronous mode with Servo Control Cyclic and acyclic data exchange with DriveES SIMATIC components Fault diagnostics of the drive via the bus system Practical exercises on the SINAMICS S120 and SIMATIC S7 training cases with CPU 315-2DP
Siemens D 12 2006
8/5
Application
Design
Cabinet operator panel with line connection Internal 24 V DC power supply Can be set upright for demonstration purposes Offline functions Online functions with SINAMICS CU320 Control Unit via RS 232 PPI.
Technical data
AOP30 cabinet operator panel training case Input voltage Degree of protection in accordance with DIN VDE 0470 Width Height Depth Weight, approx. 230 V 1 AC IP00 377 mm 158 mm 277 mm 7 kg
This training case is used for the training and promotion of SINAMICS cabinet units. When used as a stand-alone unit, it is possible to carry out offline demonstrations of commissioning and usability. Online operation is implemented by connecting to a SINAMICS cabinet unit or the SINAMICS S120 training case.
6ZB2480-0CA00
8/6
Siemens D 12 2006
Overview
The documentation is supplied with the converter in PDF format on CD-ROM as standard. It consists of the following sections: Instruction manual List manual (parameter lists and function diagrams) Equipment-specific documents such as circuit diagrams, dimension drawings, arrangement diagrams and terminal diagrams Additional instruction manuals (comprehensive component descriptions) The documentation is in English. Further languages can be ordered if required (see Description of options). Attention: Due to US embargo restrictions, the documentation cannot be supplied on CD-ROM to countries such as Iran, Syria, Cuba, Sudan or Libya, as Adobe Acrobat Reader is not permitted in these countries for reading PDF documents. The documentation must be ordered in paper form when exporting converters to these countries (option D15).
Overview
SPARESonWeb - Online spare parts catalog
SPARESonWeb is a web-based tool for selecting the spare parts available for the SINAMICS system. After you have registered and entered the serial number and order number, the spare parts available for the relevant unit are displayed. The delivery state for specific orders can be displayed for all shipped SINAMICS products. http://workplace.automation.siemens.com/sparesonweb
Siemens D 12 2006
8/7
Technical consulting
Support in the planning and designing of your project from detailed actual-state analysis, target definition and consul-
ting on product and system questions right to the creation of the automation solution. 1)
In the face of harsh competition you need optimum conditions to keep ahead all the time: a strong starting position, asophisticated strategy and team for the necessary support in every phase. Service & Support from Siemens provides this support with a complete range of different services for automation and drives. In every phase: from planning and commissioning to maintenance and upgrading. Our specialists know when and where to act to keep the productivity and cost-effectiveness of your system running in top form.
Support in configuring and developing with customer-oriented services from actual configuration to implementation of the automation project. 1)
Service on site
Online support
The comprehensive information system available round the clock via Internet ranging from Product Support and Service & Support services to Support Tools in the Shop.
http://www.siemens.com/ automation/service&support
With Service On Site we offer services for startup and maintenance, essential for ensuring system availability. In Germany Phone: 0180 50 50 444 1) In the United States, call toll-free: Phone: +1 800 333 7421 In Canada, call: Phone: +1 888 303 3353
Technical support
In the operating phase of a machine or automation system we provide a comprehensive repair and spare parts service ensuring the highest degree of operating safety and reliability. In Germany Phone: 0180 50 50 448 1) In the United States, call toll-free: Phone: +1 800 241 4453 In Canada, call: Phone: +1 888 303 3353
Product registration
To guarantee our servicing performance (availability of spare parts, hotline function, readiness of personnel), we offer you product registration for our SINAMICS drive equipment. Feedback on the final destination (installation/operation location) and naming of contact partners allows a servicing response without delay. The feedback can be made either using a feedback form (enclosed with each converter) or via the Internet: http://www.siemens.com/reg
8/8
Siemens D 12 2006
Appendix
9
9/2 9/4 9/5 Glossary Siemens contacts worldwide A&D online services A&D in the WWW Product selection using the Interactive Catalog Easy shopping with the A&D Mall Index of order numbers Subject index Terms and conditions of sale and delivery Export regulations 9/6 9/7 9/8 9/9
Siemens D 12 2006
Appendix
SINAMICS GM150/SINAMICS SM150
Glossary
Overview
Active Infeed Overall functionality of an infeed with "Active Line Module" including the required additional components (filters, switching devices, computing power portion of a "Control Unit", voltage detection, etc.). For cabinet units, a "Motor Module" can be used instead of the "Active Line Module". Active Line Module This controlled, self-commutating feed/feedback unit (with IGBTs infeed/feedback device) supplies a constant DC link voltage for the "Motor Modules". Basic Infeed Overall functionality of an infeed with "Basic Line Module" including the required additional components (filters, switching devices, etc.). Basic Line Module Unregulated line infeed unit (diode bridge or thyristor bridge, without power feedback to the line) for rectifying the line voltage of the "DC link". CompactFlash card Memory card for non-volatile storing of the drive software and of the corresponding parameters. The memory card can be plugged in the "Control Unit" from outside. Control Unit Central control module: The feedforward and feedback control functions for several SINAMICS "Line Modules" and/or "Motor Modules" are implemented in this module. DC link The component of the converter (or converter system) that connects the input converter (rectifier) and the output converter (one or more converters). With voltage source DC link converters like SINAMICS, a constant DC voltage is present in the DC link (rectified line voltage). DRIVE-CLiQ Abbreviation of "Drive Component Link with IQ". Communication system for connecting the various components of a SINAMICS drive system, such as the "Control Unit", the "Line Modules", the "Motor Modules", the "motors" and the speed/position encoders. The DRIVE-CLiQ hardware is based on the Industrial Ethernet standard and uses twisted-pair lines. The DRIVE-CLiQ line provides the transmit and receive signals and also the +24 V power supply. Field weakening The term field weakening designates the reduction of the magnetizing current of an electric motor to further increase the speed upon reaching the rated current. Induction motor The induction motor is an three-phase motor whose speed runs "behind" the synchronous speed. Induction motors can be connected to the three-phase system either directly in a star or delta connection or via a converter. In combination with a converter, the induction motor becomes a "variable speed drive system". Further, generally used terms: Squirrel-cage induction motor, squirrel-cage motor. See also "synchronous motor" Kinetic buffering The kinetic buffering function (KIP) is a software function which can be used to buffer brief power failures (up to approx. 1 s or as long as the drive is still rotating). As a rule, kinetic buffering is only used for drives which are predominantly in the motoring mode. The prerequisite is that the driven load must have a sufficiently high moment of inertia, i.e. have sufficient kinetic energy. During the power failure, the KIP function initiates a motor switchover to the no-load operation or slightly regenerative operation (in order to cover the low losses of the motor and inverter). After the resumption of power supply, the drive system switches immediately back to normal motoring operation. If kinetic buffering is to be used, it is important that the process can tolerate that the motor coasts down or decelerates during the power failure. For some applications involving multi-motor drives during the kinetic buffering phase, the speed relationships between the individual drives should be maintained so that the material web neither breaks nor is damaged. For cases such as these, it is only permissible to activate the kinetic buffering for one drive - normally the main drive. The reduced speed setpoints must be fed into the complete setpoint cascade. Line Module A line module is a power section which creates the DC link voltage for one or several "Motor Modules", from a three-phase line voltage. The following line module types are used for SINAMICS: "Basic Line Module", and "Active Line Module".
9/2
Siemens D 12 2006
Appendix
SINAMICS GM150/SINAMICS SM150
Glossary
Overview (continued)
Motor Module A motor module is a power section (DC-AC inverter) ensuring the power supply for the connected motor. Power is supplied through the "DC link" of the drive group. A motor module must be connected to a "Control Unit" via "DRIVE-CLiQ". The controller and closed-loop control functions of the motor module are stored in the Control Unit. Non-Siemens motor A motor is designated as a non-Siemens motor if its motor data is not known to the drive unit, and it cannot be identified by means of its order number. The motor data of an external motor is required for commissioning. It must be entered manually in the corresponding parameters. Output reactor Reactor (inductivity) in the converter or inverter output for reducing the capacitive charge/discharge currents of long power cables. PROFIBUS Field bus in accordance with the IEC 61158 standard, section 2 to 6. PROFIdrive This PROFIBUS profile was specified for speed- and positioncontrolled drives by the PROFIBUS under organization (PNO). The PROFIdrive V3 profile is the latest version. Sine-wave filter The sine-wave filter is connected to the converter or inverter output on the motor side. This filter has been designed for the generation of a converter output voltage with an almost sinusoidal shape. This method protects motors whose insulation system could be damaged by voltage peaks. In addition to this, a shielded power cable is not required in many cases. Sine-wave filters are often required in the chemical industry. e.g. to ensure that the permissible insulation voltage in the motor terminal box is not exceeded. Synchronous motor Synchronous motors run at the same frequency with which they are operated. They do not have a slip (like "induction motors"). Synchronous motors require different feedforward and feedback control concepts depending on their design to ensure that they can be operated with converters. Synchronous motors are distinguished by the following features: permanently/separately excited with/without damping cage with/without position encoder Synchronous motors are used for different reasons: high drive dynamic response high overload capability high speed accuracy with exactly specified frequency (SIEMOSYN motors) Terminal Module Terminal extension module for snapping on the installation rail, for installation in the control cabinet. With SINAMICS, there is the TM31 Terminal Module with analog and digital I/O terminals. Sensor Module Hardware module for evaluation of speed/position encoder signals.
Siemens D 12 2006
9/3
Appendix
SINAMICS GM150/SINAMICS SM150
Siemens contacts worldwide
At http://www.siemens.com/automation/partner you can find details of Siemens contact partners worldwide responsible for particular technologies. You can obtain in most cases a contact partner for technical support, spare parts/repairs, service, training, sales or consultation/engineering. You start by selecting a country, product or sector. By further specifying the remaining criteria you will find exactly the right contact partner with his/her respective expertise.
9/4
Siemens D 12 2006
Appendix
SINAMICS GM150/SINAMICS SM150
A&D online services
Siemens D 12 2006
9/5
Appendix
SINAMICS GM150/SINAMICS SM150
Index of order numbers
6SW1700- 6SY8101-0AB5.
6/11 6/2
6ZB2480-0CA00 E86060-
8/6 8/2
9/6
Siemens D 12 2006
Appendix
SINAMICS GM150/SINAMICS SM150
Subject index
Subject index
A Accessories AOP30 AOP30 cabinet operator panel training case AOP30 operator panel B Benefits SINAMICS GM150 in IGBT version SINAMICS GM150 in IGCT version SINAMICS SM150 C Circuit-breakers Circuit designs SINAMICS GM150 in IGBT version SINAMICS GM150 in IGCT version SINAMICS SM150 Configuration Cooling unit D Derating factors SINAMICS GM150 in IGBT version SINAMICS GM150 in IGCT version SINAMICS SM150 Description of options Design SINAMICS GM150 in IGBT version SINAMICS GM150 in IGCT version SINAMICS SM150 Documentation Drive ES F Function SINAMICS GM150 in IGBT version SINAMICS GM150 in IGCT version SINAMICS SM150 I Introduction M Motors
Part/Page 6 2/7, 3/7 8/6 2/7, 3/7 O Options SINAMICS GM150 in IGBT version SINAMICS GM150 in IGCT version SINAMICS SM150 Overview SINAMICS SINAMICS GM150/SINAMICS SM150 SINAMICS GM150 in IGBT version SINAMICS GM150 in IGCT version SINAMICS SM150 Overview of connections Overview of interfaces P Power cables S Selection and ordering data SINAMICS GM150 in IGBT version SINAMICS GM150 in IGCT version SINAMICS SM150 Service & Support Services and documentation SIMATIC OP 177B SIMATIC OP 177B operator panel SINAMICS GM150 in IGBT version SINAMICS GM150 in IGCT version SINAMICS overview SINAMICS SM150 SPARESonWeb online spare parts catalog STARTER Static excitation units T Technical data SINAMICS GM150 in IGBT version SINAMICS GM150 in IGCT version SINAMICS SM150 Training Transformers
Part/Page 5 2/12 to 2/16 3/8 to 3/13 4/8 to 4/13 1/6 1/9 2/2 3/2 4/2 7/3, 7/4 7/3 to 7/7 7/12
2/2 3/2 4/2 7/10 2/4, 2/5 3/4, 3/5 4/4, 4/5 7 7/8, 7/9
2/8 to 2/11 3/8 4/8 8/8 8 4/7 4/7 2 3 1/6 4 8/7 6/10 6/2 to 6/9
Siemens D 12 2006
9/7
Appendix
SINAMICS GM150/SINAMICS SM150
Terms and conditions of sale and delivery
9/8
Siemens D 12 2006
Appendix
SINAMICS GM150/SINAMICS SM150
Export regulations
Export regulations
The products listed in this catalog/price list may be subject to European/German and/or US export regulations. Therefore, any export requiring a license is subject to approval by the competent authorities. According to current provisions, the following export regulations must be observed with respect to the products featured in this catalog/price list: AL Number of the German Export List Products marked other than N require an export license. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an AL not equal to N are subject to a European or German export authorization when being exported out of the EU. Export Control Classification Number Products marked other than N are subject to a reexport license to specific countries. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an ECCN not equal to N are subject to a US re-export authorization. Even without a label or with an AL: N or ECCN: N, authorization may be required due to the final destination and purpose for which the goods are to be used. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices. Errors excepted and subject to change without prior notice.
A&D/VuL/En 17.03.05
ECCN
Siemens D 12 2006
9/9
Appendix
SINAMICS GM150/SINAMICS SM150
Siemens AG Automation and Drives Large Drives Postfach 47 43 90025 NUERNBERG FEDERAL REPUBLIC OF GERMANY
9/10
Siemens D 12 2006
Hardware- and software requirements Intel Pentium 333 MHz or higher At least 128 Mbyte RAM Screen resolution 1024 x 768 pixels 4 x CD-ROM drive
Windows 9x/NT 4.x/2000/XP Acrobat Reader Excel 2000 Microsoft Internet Explorer version 5.5 and higher
Start Insert the CD into the CD-ROM drive. The program starts automatically. If the AutoRun function is not activated in your system, please start the start.hta file from the CD-ROM in Windows Explorer. If Excel is not installed on your PC, you can use the Excel viewer (xlviewer.exe) supplied on the CD-ROM. Note No programs have to be installed to view the information on this CD-ROM.
Catalogs of the
Automation and Drives Group (A&D)
Further information can be obtained from our branch offices listed in the appendix or at www.siemens.com/automation/partner
Automation and Drives Interactive catalog on CD-ROM and on DVD The Offline Mall of Automation and Drives Automation Systems for Machine Tools SINUMERIK & SIMODRIVE SINUMERIK & SINAMICS Drive Systems Variable-Speed Drives SINAMICS G130 Drive Converter Chassis Units, SINAMICS G150 Drive Converter Cabinet Units SINAMICS G110 Inverter Chassis Units SINAMICS GM150/SINAMICS SM150 Medium-Voltage Converters SINAMICS S120 Vector Control Drive System SINAMICS S120 Servo Control Drive System SINAMICS S150 Drive Converter Cabinet Units Asynchronous Motors Standardline DC Motors SIMOREG DC MASTER 6RA70 Digital Chassis Converters SIMOREG K 6RA22 Analog Chassis Converters SIMOREG DC MASTER 6RM70 Digital Converter Cabinet Units SIMOVERT PM Modular Converter Systems SIEMOSYN Motors MICROMASTER 410/420/430/440 Inverters MICROMASTER 411/COMBIMASTER 411 SIMOVERT MASTERDRIVES Vector Control SIMOVERT MASTERDRIVES Motion Control Synchronous and asynchronous servomotors for SIMOVERT MASTERDRIVES SIMODRIVE 611 universal and POSMO Low-Voltage Three-Phase-Motors Squirrel-Cage Motors, Totally Enclosed, Fan-Cooled Automation Systems for Machine Tools SIMODRIVE Main Spindle/Feed Motors Converter Systems SIMODRIVE 611/POSMO Automation Systems for Machine Tools SINAMICS Main Spindle/Feed Motors Drive System SINAMICS S120 Drive and Control Components for Hoisting Equipment Electrical Installation Technology ALPHA Small Distribution Boards and Distribution Boards PDF: ALPHA 8HP Molded-Plastic Distribution System ALPHA FIX Terminal Blocks BETA Modular Installation Devices DELTA Switches and Socket Outlets GAMMA Building Management Systems Human Machine Interface Systems SIMATIC HMI HE 1 NC 61 M 11 NC 60 D 11 D 11.1 D 12 D 21.1 D 21.2 D 21.3 D 86.1 DA 12 DA 21.1 DA 21.2 DA 22 DA 45 DA 48 DA 51.2 DA 51.3 DA 65.10 DA 65.11 DA 65.3 DA 65.4 SIMATIC Industrial Automation Systems SIMATIC PCS Process Control System Products for Totally Integrated Automation and Micro Automation SIMATIC PCS 7 Process Control System Add-ons for the SIMATIC PCS 7 Process Control System Migration solutions with the SIMATIC PCS 7 Process Control System pc-based Automation SIMATIC Control Systems SIMATIC Sensors SIPOS Electric Actuators Electric Rotary, Linear and Part-turn Actuators Electric Rotary Actuators for Nuclear Plants Systems Engineering Power supplies SITOP power System cabling SIMATIC TOP connect System Solutions Applications and Products for Industry are part of the interactive catalog CA 01 TELEPERM M Process Control System PDF: AS 488/TM automation systems ST 45 ST 70 ST PCS 7 ST PCS 7.1 ST PCS 7.2 ST PC ST DA FS 10 Catalog CA 01 Low-Voltage Controls and Distribution SIRIUS, SENTRON, SIVACON Controls and Distribution Technical Information SIRIUS, SENTRON, SIVACON SIDAC Reactors and Filters SIVENT Fans SIVACON 8PS Busbar Trunking Systems Motion Control System SIMOTION Process Instrumentation and Analytics Field Instruments for Process Automation Measuring Instruments for Pressure, Differential Pressure, Flow, Level and Temperature, Positioners and Liquid Meters PDF: Indicators for panel mounting SIREC Recorders and Accessories SIPART, Controllers and Software SIWAREX Weighing Systems Continuous Weighing and Process Protection Process Analytical Instruments PDF: Process Analytics, Components for the System Integration LV 1 LV 1 T Industrial Communication for Automation and Drives Catalog IK PI
NC 60 NC 61
LV 60 LV 65 LV 70 PM 10
FI 01
MP 12 MP 20 MP 31 WT 01 WT 02 PA 01 PA 11
MP 35 MP 35.1/.2
ET A1 ET A3 ET A5 ET B1 ET D1 ET G1 ST 80
KT 10.1 KT 10.2
PLT 112
The information provided in this catalog contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice.
Siemens AG Automation and Drives Large Drives Postfach 4743 90025 NUERNBERG FEDERAL REPUBLIC OF GERMANY http://www.siemens.com/sinamics Order No. E86060-K5512-A101-A1-7600