Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
89 views58 pages

AT N4010A Manual

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 58

Getting Started Guide

Wireless Connectivity Test Set


N4010A

Manufacturing Part Number: N4010- 90044


Printed in UK
November 2005

© Copyright Agilent Technologies UK Limited 2005


General
The material contained in this document is provided “as is,” and is
subject to being changed, without notice, in future editions. Further, to
the maximum extent permitted by applicable law, Agilent disclaims all
warranties, either express or implied with regard to this manual and
any information contained herein, including but not limited to the
implied warranties of merchantability and fitness for a particular
purpose. Agilent shall not be liable for errors or for incidental or
consequential damages in connection with the furnishing, use, or
performance of this document or any information contained herein.
Should Agilent and the user have a separate written agreement with
warranty terms covering the material in this document that conflict
with these terms, the warranty terms in the separate agreement will
control.

Station Road, South Queensferry, Scotland, EH30 9TG, UK.

ii
Legal Information
Certification
Agilent Technologies certifies that this product met its published
specifications at the time of shipment from the factory. Agilent
Technologies further certifies that its calibration measurements are
traceable to the United States National Institute of Standards and
Technology, to the extent allowed by the Institute’s calibration facility,
and to the calibration facilities of other International Standards
Organization members.

Safety Symbols
The following symbols on the Test Set and in the documentation
indicate precautions which must be taken to maintain safe operation
of the Test Set.

This is the ‘Caution - Refer to Instruction


Documentation’ Symbol. The product is
marked with this symbol when it is necessary
for the user to refer to the instructions in the
supplied documentation.

Alternating current (AC)

This symbol indicates the position of the


operating switch for ‘Stand- by’ mode. Note,
the Test Set is NOT isolated from the mains
when the switch is in this position. To isolate
the Test Set, the mains coupler (mains input
cord) should be removed from the power
supply.

iii
Safety Notices
This guide uses warnings and cautions to denote hazards

WARNING Warning denotes a hazard. It calls attention to a procedure, which if


not correctly performed or adhered to, could result in injury or loss of
life. Do not proceed beyond a warning until the indicated conditions
are fully understood and met.

CAUTION Caution denotes a hazard. It calls attention to a procedure, which if


not correctly performed or adhered to, could result in damage to or
destruction of the instrument. Do not proceed beyond a caution until
the indicated conditions are fully understood and met.

General Safety Information


The following general safety precautions must be observed during all
phases of operation, service, and repair of this Test Set. Failure to
comply with these precautions or with specific warnings elsewhere in
this manual violates safety standards of design, manufacture, and
intended use of the Test Set. Agilent Technologies assumes no liability
for the customer’s failure to comply with these requirements.

WARNING This is a Safety Class I Test Set (provided with a protective


earthing ground, incorporated in the power cord). The mains plug
shall only be inserted in a socket outlet provided with a protective
earth contact. Any interruption of the protective conductor inside
or outside of the Test Set is likely to make the Test Set dangerous.
Intentional interruption is prohibited.

iv
DO NOT operate the product in an explosive atmosphere or in the
presence of flammable gasses or fumes.
DO NOT perform procedures involving cover or shield removal unless
you are qualified to do so: Operating personnel must not remove
equipment covers or shields. Procedures involving the removal of
covers and shields are for use by service- trained personnel only.
DO NOT service or adjust alone: Under certain conditions, dangerous
voltages may exist even with the equipment switched off. To avoid
dangerous electrical shock, service personnel must not attempt internal
service or adjustment unless another person, capable of rendering first
aid and resuscitation, is present.
DO NOT operate damaged equipment: Whenever it is possible that the
safety protection features built into this product have been impaired,
either through physical damage, excessive moisture, or any other
reason, REMOVE POWER and do not use the product until safe
operation can be verified by service- trained personnel. If necessary,
return the product to a Agilent Sales and Service Office for service
and repair to ensure the safety features are maintained.
DO NOT substitute parts or modify equipment: Because of the danger
of introducing additional hazards, do not install substitute parts or
perform any unauthorized modification to the product. Return the
product to an Agilent Sales and Service Office for service and repair
to ensure the safety features are maintained.

CAUTION Before switching on this Test Set, make sure that the correct fuse is
installed and ensure the power supply voltage si in the specified range.

CAUTION Mains supply voltage fluctuations should not exceed +/- 10% of the
nominal selected line voltage.

v
WARNING Appliance coupler (mains input power cord) is the power disconnect
device. Do not position the Test Set such that access to the coupler
is impaired.

Acknowledgements
Bluetooth® and the Bluetooth Logo® are trademarks owned by
Bluetooth SIG, Inc., U.S.A. and licensed to Agilent Technologies, Inc.

MATLAB® is a U.S. registered trademark of The Math Works, Inc.

Microsoft® is a U.S. registered trademark of Microsoft Corporation.


Windows® and MS Windows® are U.S. registered trademarks of
Microsoft Corporation.

Pentium® is a U.S. registered trademark of Intel Corporation.

vi
Contents
1. Getting Started
Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
This guide helps you to: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Initial Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Minimum PC Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
The PC must meet the following minimum requirements: . . . . . . . . . . . . . . . . . . . . . 7
Adjusting the Carrying Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Turning the Test Set On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
What Can Go Wrong? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2. Making Your First Measurements


Selecting the Application Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Running a Confidence Check on the Front Panel (Bluetooth). . . . . . . . . . . . . . . . . . . . 15
Running a SCPI Confidence Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Running a WLAN Confidence Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Running the Graphical Measurement Application (GMA) N4017A. . . . . . . . . . . . . . . 24
Connecting USB, GPIB or LAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Connecting by USB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Connecting by GPIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Connecting by LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Rack Mounting the Test Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Disconnect Device Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Ventilation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Rack Mounting
Using the Option N4010A-AX4 rack mount kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

3. Regulatory Information
General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Power Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Cooling Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Compliance and Markings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Electromagnetic Compatibility (EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

vii
Contents
Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Regulatory Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Sound Emission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Responsibilities of the Customer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Agilent Sales and Service Offices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

viii
1 Getting Started

Chapter 1 1
Getting Started
Welcome

Welcome
Welcome to the Agilent Technologies Wireless Connectivity Test Set’s
Getting Started Guide. This guide is for use with the N4010A
containing any of the following installed options:

NOTE The process to view the options in your Test Set is described later.

• Option 101 - Bluetooth RF tests.


• Option 102 - 802.11b and 802.11g 2.4GHz WLAN tests.
• Option 103 - 802.11b, 802.11g (2.4GHz), and 802.11a (5GHz) WLAN
tests.
• Option 104 - Arbitrary Waveform File Download.
• Option 105/106 Bluetooth EDR Tx/Rx measurements.
• Option 110 - I/O Connectivity.
• Option 111 - Bluetooth Audio Capability.
• Option 112 - Headset Profiles.
• Option 204 - Signal Studio for 802.11 WLAN.
• N4017 Graphical Meaurement Application.
This guide is only part of the information supplied with the Agilent
N4010A Wireless Connectivity Test Set. Its purpose is to show you how
to check your Test Set, switch it on and confirm the Test Set
functions.

2 Chapter 1
Getting Started
Introduction

Introduction
The Agilent N4010A Wireless Connectivity Test Set is a one- box test
set for, Bluetooth and WLAN, module and appliance manufacturing
test.
The test set can be configured to measure the following standards:

• Bluetooth RF tests
• Bluetooth Audio Capability tests
• 802.11b (2.4 GHz) WLAN tests
• 802.11g (2.4 GHz) WLAN tests
• 802.11a (5.0 GHz) WLAN tests
Control of the test set for Bluetooth measurements differs from control
for making WLAN measurements, see Table 1-1 on page 4.

Chapter 1 3
Getting Started
Introduction

Table 1- 1 Test Set Control Differences Between Bluetooth and WLAN

Function Bluetooth Test Bluetooth EDR WLAN Testa


Test

Front Panel Full control using Limited to Limited to


Operation front Panel Keys system settings system settings
and displayed
menu system

Remote SCPI programming Only via PC Only using a PC


Interface commands resident resident
Operation programming programming
interface Agilent interface Agilent
N4010 EDR N4010 WLAN
Driver Test
Test Configured within Configured with Only Spectral
Sequence Test Set your own test Mask
Control executive measurement
program tests to specified
limits. All other
limits configured
within your own
test executive
program.

Test to Configured within Configured with Configured


Limits Test Set your own test within your own
executive test executive
program program

Control of via LMP DUT control from


Test Device commands from test executive
Test Set and EUT only using device
HCI control from specific drivers
test executive
Remote GPIB, LAN and USB 2.0 or LAN USB 2.0 or LAN
interfacing USB preferred. GPIB preferred. GPIB
possible. possible.

a. Option 110 is required for the operation of WLAN and Bluetooth


EDR tests.

4 Chapter 1
Getting Started
This guide helps you to:

This guide helps you to:


• initially inspect the Test Set.
• know the PC minimum requirements.
• adjust the carrying handle.
• switch the Test Set on and confirm it passes the power- on self test.
• run a Bluetooth confidence check using front panel operation.
• run a Bluetooth confidence check using the remote interface option.
• run a WLAN confidence check using the test harness application.
• run a SCPI confidence check using the Connection Expert
application.
• make connections to the rear panel.
• attach the rack mounting kits (supplied with option N4010A- AX4).

Chapter 1 5
Getting Started
Initial Inspection

Initial Inspection
Please inspect the shipping container for damage. If the shipping
container or packaging material is damaged, please keep it until the
contents have been checked mechanically and electrically. If there is
mechanical damage, notify the nearest Agilent Technologies office.
Keep the damaged shipping materials (if any) for inspection by the
carrier and an Agilent representative. If required, you can find a list of
“Agilent Sales and Service Offices” on page 50.
Before continuing, please ensure you have read and understood the
preceding safety information.

6 Chapter 1
Getting Started
Minimum PC Requirements

Minimum PC Requirements

The PC must meet the following minimum requirements:


• Windows® 2000 (SP4 or greater) or XP® Pro SP2 or XP® Home SP2.
• 1.8 GHz Pentium® or equivalent minimum, 2.0 GHz recommended.
• 256 Mbytes RAM.
• USB 2.0, GPIB or TCP/IP LAN connection to Test Set.
• 1024 x 768 pixel display.
• CD- ROM Drive or Internet connection for application download.
• Internet connection for license redemption.

Chapter 1 7
Getting Started
Adjusting the Carrying Handle

Adjusting the Carrying Handle


Adjust the carrying handle to carry the Test Set or view the display.

The carrying handle can be locked into three different positions.

Pull the handle outwards, rotate it to the required position and


release it into one of the three locks.

If you want to remove the handle, refer to “Rack Mounting the Test
Set” on page 39.

8 Chapter 1
Getting Started
Turning the Test Set On

Turning the Test Set On

CAUTION The Test Set has an autoranging power supply. Ensure the supply
voltage is within the range 100 Vac to 240 Vac and 50 Hz to 60 Hz.

1. Connect the Power Cord.

2. Check that the background LED is red.

Chapter 1 9
Getting Started
Turning the Test Set On

3. Turn the test set on and confirm the background LED is


green.

4. The test set automatically steps through a self test routine.


After this routine you should see the following display...

5. The Test Set is now ready for use.

NOTE If the test set has been stored in extremely cold conditions, beyond its
normal operating range, the display may require a few minutes to
warm up and operate normally.

10 Chapter 1
Getting Started
Turning the Test Set On

What Can Go Wrong?


See this Do this

Red LED not lit Check that power is supplied to the test
set.
Check the Test Set fuse. (see below)
Fails self test(s) If there are any self- test failures the test
set is defective. Contact your nearest
Agilent Service Center (Refer to Agilent
Sales and Service Offices on page 50).

In line fuse

Spare fuse

Chapter 1 11
Getting Started
Turning the Test Set On

12 Chapter 1
2 Making Your First Measurements

Chapter 2 13
Making Your First Measurements
Selecting the Application Mode

Selecting the Application Mode


The purpose of this guide is to allow you to confirm the Test Set
functions for a specific application.

• To perform a confidence check for Bluetooth local control only,


refer to “Running a Confidence Check on the Front Panel
(Bluetooth)” on page 15.
• To perform a confidence check for SCPI commands, refer to
“Running a SCPI Confidence Check” on page 18.
• To perform a confidence check for WLAN, refer to “Running a WLAN
Confidence Check” on page 20.
• To perform a confidence check for Bluetooth remote use with the
N4017A Graphical Measurement Application, refer to “Running the
Graphical Measurement Application (GMA) N4017A.” on page 24.

14 Chapter 2
Making Your First Measurements
Running a Confidence Check on the Front Panel (Bluetooth)

Running a Confidence Check on the Front Panel


(Bluetooth)
To operate Bluetooth testing from the Front Panel, your N4010A must
be configured with:
• Option 101.
Refer to the N4010A web page at www.agilent.com/find/N4010A for
firmware updates.
To verify your configuration, press the System key, an example is
shown in Figure 2-1.

Figure 2- 1 Typical System Configuration Screen

To run a confidence check you also require a Bluetooth device, for


example, a Bluetooth enabled mobile phone.

1. Make the Equipment Under Test (EUT) discoverable. Refer to


manufacturer’s handbook for instructions.
2. Fix an antenna to the RF IN/OUT or connect EUT directly to the
connector. Shown in Figure 2-2.

Figure 2- 2 Test Set RFIO Connections

3. Press the Config key.

Chapter 2 15
Making Your First Measurements
Running a Confidence Check on the Front Panel (Bluetooth)

Figure 2- 3 Typical Configure Link Screen when ACL is Selected

4
5

4. Use the Arrow and Select keys to highlight and select an ACL Link
as shown in Figure 2-3.
5. Press the EUT softkey.

6. Press the Inquiry Procedure softkey.


7. In a few seconds the Inquiry Results are displayed. An example is
shown in Figure 2-4. If no device is detected, check the EUT
connection, and press the Restart Inquiry softkey.

NOTE To apply Loss Compensation, for example for cable loss:


Press Mode, Loss Comp . Use the Select key to check the Apply Loss
Compensation box. Use the arrow keys and numeric pad to enter
values in the Fixed Loss field. Press the dB softkey.

Figure 2- 4 Typical Inquiry Results Screen

7
9

8. Ensure your device is highlighted in yellow, use the arrow keys if

16 Chapter 2
Making Your First Measurements
Running a Confidence Check on the Front Panel (Bluetooth)

necessary, as shown in Figure 2-4.

9. Press the Select & Return BDA softkey.


10. Press the Results key.
11. Press the Run/Resume key.
12. The Test Plan Results are populated with Pass or Fail (“P” or “F”).
An example is shown in Figure 2-5.

Figure 2- 5 Typical Results Screen

NOTE It is not important whether the tests pass or fail. It is only important
that some results are populated.

Congratulations the Front Panel Bluetooth Confidence Check is


complete.

Chapter 2 17
Making Your First Measurements
Running a SCPI Confidence Check

Running a SCPI Confidence Check


Step 1. Install the Agilent I/O Libraries Suite software

1. Insert the Agilent Automation- Ready into your CD drive and


install using the on- screen instructions.

If the CD does not auto- start, from your windows task bar select
Start > Run. In the field enter <CDdrive>:\autorun\auto.exe
where <CDdrive> is the letter of your CD drive.

2. Close the Agilent IO libraries Suite 14.1 installation window.

3. Close the Agilent Connection Expert program.


4. You have completed Step 1 of the 3 Step process.

Step 2. Connecting the Test Set

Refer to “Connecting USB, GPIB or LAN” on page 30.

18 Chapter 2
Making Your First Measurements
Running a SCPI Confidence Check

Step 3. Sending SCPI commands

1. In the Agilent Connection Expert program, click on Refresh All.


2. Select the Test Set from the Instrument I/O on this PC panel as
shown in Figure 2-6. If you do not see your Test Set then expand
the appropriate connection type by clicking on the + symbol.

Figure 2- 6 Connection Expert Screen

1
2
3

3. Right Click on the Test Set listing.


4. Select Send Commands to this Instrument.
5. Click on Send & Read.
6. The program displays the manufacturer, model number and serial
information. Check this information matches the Test Set.
Congratulations the SCPI confidence check is complete.

Chapter 2 19
Making Your First Measurements
Running a WLAN Confidence Check

Running a WLAN Confidence Check


To operate a WLAN Confidence Check, your N4010A Test Set must be
configured with:

• Firware revision A.02.00.11 or later


• Option 102 or Option 103
• Option 104 Arbitrary Waveform File Download
• Option 204 Signal Studio license
Refer to the N4010A web page at www.agilent.com/find/N4010A for
firmware updates.
To verify your configuration, press the System key, an example is
shown in Figure 2-7.

Figure 2- 7 Typical System Configuration Screen

20 Chapter 2
Making Your First Measurements
Running a WLAN Confidence Check

Step 1. Install the N4010A Wireless LAN Test Suite.


1. Insert the CD Wireless LAN test suite.

If the CD does not auto- start, from your task bar select Start >
Run. In the field enter <CDdrive>:\setup where <CDdrive> is the
letter of your CD drive.

2. Click on Install or Upgrade N4010A WLAN Test Suite.

NOTE If not already installed on your computer the N4010A WLAN Test
Suite automatically installs Microsoft .NET Framework service pack 1
and Agilent IO Connection suite.

3. Follow the on- screen instructions. The Installation Wizard requires


a reboot of the PC in this process.

4. The Install Shield Wizard completes.


5. Uncheck the Launch Agilent Connection Expert check box.

6. Click on Finish.

Step 2. Refer to “Connecting USB, GPIB or LAN” on page 30.

NOTE For the WLAN test program, LAN or USB are the recommended
connection solutions. GPIB can be used, however, due to its lower data
rate transfer is not suitable for some features of WLAN testing.

Chapter 2 21
Making Your First Measurements
Running a WLAN Confidence Check

Step 3. Rename the Test Set in Connection Wizard.

1. In the Agilent Connection Expert, Click on Refresh All as shown


in Figure 2-8.
2. From the Instrument I/O on this PC panel, select your Test Set
listing with a right click. If you do not see your Test Set expand the
appropriate connection type by clicking on the + symbol.

Figure 2- 8 Typical Connection Expert Screen

3. Click on Add Visa Alias.


4. Enter your new Visa Alias Name, remember this as it is used in
step 4. For example “MyNewInstrument”, do not use spaces.

5. Click on OK.

Step 4. Running the Test Harness Program.


1. Run the Test Harness program, from the windows task bar,
Start>All Programs>Agilent N4010 WLAN Test suite>Sample
Program - Test Harness.

2. In the field marked Instrument, enter the Visa Alias Name of the
Test Set (created in Step 3.4).

3. Click on Create.
In a few seconds the Test Set’s display turns yellow.

22 Chapter 2
Making Your First Measurements
Running a WLAN Confidence Check

4. Click on the Demo tab.

5. Click on Run Demo.

6. The display shows a loopback waveform similar to Figure 2-9.

Figure 2- 9 Test Harness Demo Screen

Congratulations the WLAN Confidence Check is complete.

Chapter 2 23
Making Your First Measurements
Running the Graphical Measurement Application (GMA) N4017A.

Running the Graphical Measurement


Application (GMA) N4017A.
The N4017A Bluetooth Graphical Measurement Application, is a PC
based software application that works in a complementary manner
with the N4010A Wireless Connectivity Test Set. The GMA makes it
possible to fully configure the Test Set remotely.
To operate with the Bluetooth GMA, your N4010A Test Set must be
configured with:

• Firmware revision A.02.00.11 or later


• Option 101
• Option 110
Refer to the N4010A web page at www.agilent.com/find/N4010A for
firmware updates.
To verify your configuration, press the System key, an example is
shown in Figure 2-10.

Figure 2- 10 Typical System Configuration Screen

24 Chapter 2
Making Your First Measurements
Running the Graphical Measurement Application (GMA) N4017A.

Step 1. Installing the Bluetooth GMA


1. Insert the Agilent Automation- Ready CD into your CD drive and
install using the on- screen instructions.

If the CD does not auto- start, from your windows task bar select
Start > Run. In the field enter <CDdrive>:\autorun\auto.exe
where <CDdrive> is the letter of your CD drive.

2. Close the Agilent IO libraries Suite 14.1 installation window.


3. Close the Agilent Connection Expert program.

4. Insert the Agilent N4017A Bluetooth GMA CD into your CD drive


and install by using the on- screen instructions.

If the CD does not auto- start, from your windows task bar select
Start > Run. In the field enter <CDdrive>:\setup.exe where
<CDdrive> is the letter of your CD drive.

NOTE If Microsoft .NET Framework version 1.1 service pack 1 is not


installed on your computer, the GMA installation halts and requests
you to re- run the installation after installing the Microsoft .NET
Framework service pack 1. From the windows task bar select Start >
Run. Click on Browse.

Navigate to <CDdrive>:\Microsoft .NET Framework 1.1\Select


the file NDP1.1sp1-KB867460-X86.exe

Click Open. Click OK. Follow the on- screen instructions.

5. Use the information on your Software Entitlement Certificate to


obtain and install the GMA license.

6. Close all programs.

You have completed Step 1 of the 3 Step process.

Chapter 2 25
Making Your First Measurements
Running the Graphical Measurement Application (GMA) N4017A.

Step 2. Connecting the Test Set

Refer to “Connecting USB, GPIB or LAN” on page 30.

Step 3. Using the GMA

1. Check the EUT is powered and is discoverable (see manufacturer’s


handbook for information).

2. Connect the EUT directly or via an antenna as shown in Figure


2-11.

Figure 2- 11 Test Set RFIO Connections

3. Minimize the Connection Expert program.


4. Run the GMA program from the windows task bar using, Start>All
Programs>Agilent N4017A Bluetooth GMA>N4017A Bluetooth
GMA or double click the desktop icon if created during the
installation.

26 Chapter 2
Making Your First Measurements
Running the Graphical Measurement Application (GMA) N4017A.

5. Use the Instrument Selector to locate your Test Set from the
appropriate connection you have made. If you do not see your Test
Set then expand the appropriate connection type by clicking on the
+ symbol.

Figure 2- 12 Typical GMA Instrument Selector Screen

6. Double Click your Test Set listing or Click on Select Instrument.

7. The GMA finishes loading and your Test Set’s display turns yellow.

8. In the GMA program, click on the Test Mode Link tab.

9. Click on Connection Control.

Chapter 2 27
Making Your First Measurements
Running the Graphical Measurement Application (GMA) N4017A.

Figure 2- 13 Typical Connection Control Screen

11
13

10

14

10. In the Inquiry section, click on Start.

11. The EUT’s numbers appear in a few seconds.

12. Click on the EUT’s numbers to highlight it.


13. Click on Select.

14. Click on OK.

28 Chapter 2
Making Your First Measurements
Running the Graphical Measurement Application (GMA) N4017A.

15. In the Control menu, click Run Single.


16. The test parameters are populated with PASS or FAIL information,
an example is shown in Figure 2-14.

Figure 2- 14 Typical Results Screen in the GMA

16

NOTE It is not important whether the tests pass or fail. It is only important
that some results are populated.

Congratulations the Remote Bluetooth Confidence Check is


Complete.

Chapter 2 29
Making Your First Measurements
Connecting USB, GPIB or LAN

Connecting USB, GPIB or LAN


The Test Set can be remotely controlled by USB, GPIB (IEEE488) or
LAN programming interfaces. Only one interface can be used at a time.

• To Connect by USB refer to “Connecting by USB” on page 31.


• To Connect by GPIB refer to “Connecting by GPIB” on page 32.
• To Connect by LAN refer to “Connecting by LAN” on page 34.
For more detailed information on configurating the remote interface
connectivity, refer to the Agilent Technologies USB, LAN or GPIB
Interfaces Connectivity Guide. You can access the Connectivity Guide
via the Agilent IO Libraries Control icon. Alternatively, you can access
the Connectivity Guide via the internet at
www.agilent.com/find/connectivity.

30 Chapter 2
Making Your First Measurements
Connecting USB, GPIB or LAN

Connecting by USB

The USB interface requires no front panel configuration. USB


operation and configuration is supported by the version of VISA and
SICL I/O libraries on your computer.

1. Switch on and connect the Wireless Connectivity Test Set to your


computer using the supplied Type A to B Mini 5 pin USB cable.
2. The Found New Hardware Wizard appears.
In the prompt select No, not this time, Click Next.
Click Next to install the software automatically.
By installing the Agilent I/O Libraries software, you also installed
low- level drivers. This means you do not need to insert the drivers
CD when the wizard requests it.
3. Follow the on- screen instructions to complete USB installation.
4. On Assign USB device alias screen, click Cancel.
5. Run the Connection Expert program. It can be opened by double
clicking the the icon in the task bar notification area or from
the windows task bar, Start>All Programs>Agilent IO Libraries
Suite>Agilent Connection Expert.
6. You have successfully completed Step 2 of the 3 Step Process. To
complete the confidence check for:

• Bluetooth GMA, refer to Step 3 “Using the GMA” on page 26.


• WLAN, refer to Step 3 “Rename the Test Set in Connection
Wizard.” on page 22.
• SCPI, refer to Step 3 “Sending SCPI commands” on page 19.

Chapter 2 31
Making Your First Measurements
Connecting USB, GPIB or LAN

Connecting by GPIB

Changing the GPIB Address


The GPIB address is an integer between 0 and 30. The Test Set is
shipped with a default address set to 15. The GPIB address is stored
in non- volatile memory.
To change the GPIB address manually.

Press System, Comms .


Use the Numeric keys on front panel to enter the required GPIB
address in the field. Press the Enter softkey.
Connecting to your Computer

1. Follow your GPIB interface card vendor’s instructions for installing


and configuring GPIB hardware on your computer.
2. Connect a GPIB cable between your computer and the Test Set.
3. Run the Connection Expert program. It can be opened by double
clicking the icon in the task bar notification area or from the
windows task bar, Start>All Programs>Agilent IO Libraries
Suite>Agilent Connection Expert.
In the Connection Expert program, click on Refresh All.

32 Chapter 2
Making Your First Measurements
Connecting USB, GPIB or LAN

Figure 2- 15 Typical Connection Expert Screen showing GPIB Connection

4. The Test Set is displayed under the GPIB list in the centre of the
screen.
5. You have successfully completed Step 2 of the 3 Step process. To
complete the confidence check for

• Bluetooth GMA, refer to Step 3 “Using the GMA” on page 26.


• WLAN, refer to Step 3 “Running the Test Harness Program.” on
page 22.
• SCPI, refer to Step 3 “Sending SCPI commands” on page 19.

Chapter 2 33
Making Your First Measurements
Connecting USB, GPIB or LAN

Connecting by LAN

The Test Set has two LAN operating modes.

• Dynamic Host Configuration Protocol (DHCP)


• Static IP (Manual Mode)

Configuring the Test Set


The IP Address, Subnet Mask, and Default Gateway, can be changed
manually or remotely.
The IP address, Subnet Mask, and Default Gateway values are stored
in non- volatile memory and are not part of the save- recall function.

DHCP LAN Connection.


In DHCP mode the IP Address, Subnet Mask, and Default Gateway
values are obtained automatically from the server. Using DHCP does
not require a detailed knowledge of your network configuration. Refer
to “DHCP Mode” on page 35 for further information.

Static IP LAN Connection.


In static mode you must set up the IP Address, Subnet Mask, and
Default Gateway to be compatible with your network infrastructure. To
use Static IP you need to obtain these values from your network
administrator. Refer to “Static IP” on page 38 for further information.

NOTE USB is recommended for a direct connection between your computer


and the Test Set. Refer to “Connecting by USB” on page 31.

34 Chapter 2
Making Your First Measurements
Connecting USB, GPIB or LAN

DHCP Mode
In DHCP mode the IP Address, Subnet Mask and Default Gateway
values are obtained automatically from the server. When you use DHCP
you cannot configure the IP Address, Subnet Mask or Default Gateway
values from the front panel.

1. Using standard LAN cables, connect both the computer and the
Test Set to LAN outlets.
2. Turn on the power to the Test Set.

3. Press System, Comms to display the Communications page. Ensure


that DHCP Enabled, is checked. If unchecked it can be enabled,
using the arrow keys and the Select key. Shown in Figure 2-16.

4. Press the Restart Network softkey.


The status reporting field of the Test Set displays Network
Initializing changing to Network Ready.
The IP Address, Subnet Mask and Default Gateway are populated
and greyed out. See Figure 2-16.

NOTE If the DHCP server cannot be found on your network, the Test Set
returns to static mode. The Status Reporting Field displays DHCP
rollover to static IP. If this happens, refer to “Static IP” on page 38.

Figure 2- 16 Typical Communications Display with DHCP Enabled

IP Address Fields
(greyed out)
DHCP Enabled
Check

Status Reporting
Field

Chapter 2 35
Making Your First Measurements
Connecting USB, GPIB or LAN
Configuring the Connection Expert

1. Run the Connection Expert program. It can be opened by double

clicking the icon in windows notification area or from the


windows task bar, Start>All Programs>Agilent IO Libraries
Suite>Agilent Connection Expert.

2. Right click on the LAN Interface section. Shown in Figure 2-17.


3. Choose Add Instrument. Shown in Figure 2-17.

Figure 2- 17 The Connection Expert Screen

4. In the pop up screen ensure LAN (TCIP0) is selected.


5. Click OK.

36 Chapter 2
Making Your First Measurements
Connecting USB, GPIB or LAN

6. In the pop up screen, shown in Figure 2-18, select the IP Address


link.
7. Enter the IP address which is displayed on the Test Set.
8. Click on Test Connection.
9. Click on Identify Instrument.

Figure 2- 18 LAN Instruments Selection Screen

6 7

8
9

11

10. Confirm the returned serial number matches the Test Set.
11. Click on OK.
To complete the confidence check for

• Bluetooth GMA, refer to Step 3 “Using the GMA” on page 26.


• WLAN, refer to Step 3 “Running the Test Harness Program.” on
page 22.
• SCPI, refer to Step 3 “Sending SCPI commands” on page 19.

Chapter 2 37
Making Your First Measurements
Connecting USB, GPIB or LAN

Static IP
In static mode you must set up the IP Address, Subnet Mask, and
Default Gateway that is compatible with your network infrastructure. If
it is not correctly setup, the Test Set is not be visible on your network.
If you configure an invalid IP Address or an IP address that is used by
another device or host, an error message is generated. This error can
be read by pressing System, Show Errors .

1. Using standard LAN cables, connect both the computer and the
Test Set to LAN outlets.
2. Turn on the Test Set.

Press System, Comms to display the Communications page.

Figure 2- 19 Typical Communications Screen, Entering LAN Data

IP Address
Fields DHCP Enabled
Check

Status Reporting
Field

3. Use the arrow keys and Select to disable the DHCP Enabled
setting.
4. Obtain appropriate IP Address, Subnet Mask and Default Gateway
values from your LAN administrator. Values can range between
0.0.0.0 and 255.255.255.255.
5. Use the arrow keys and numeric keypad to set the IP Address,
Subnet Mask and Default Gateway. After each field’s entry, press
the Enter & Tab softkey.

6. Press the Restart Network softkey.


The Status Reporting Field changes to display Network Ready.
7. Configure the Connection Expert, refer to “Configuring the
Connection Expert” on page 36.

38 Chapter 2
Making Your First Measurements
Rack Mounting the Test Set

Rack Mounting the Test Set

Disconnect Device Requirements


In rack mounting operation a disconnect device, for example, an
IEC320 appliance coupler, must be used. Consideration must be given
to the following when installing the Test Set in a rack:

• An adequately rated switch (250V, 10A) or circuit breaker (250V,


5A) shall be included in the rack.
• It should in close proximity to the Test Set and within easy reach
of the operator.
• It shall be marked as a disconnect device.

Ventilation Requirements
When installing the Test Set in a cabinet, the convection into and out
of the Test Set must not be restricted. If the total power dissipated in
the cabinet is greater than 800 Watts, then forced convection must be
used.

Rack Mounting
Using the Option N4010A- AX4 rack mount kit
1. Remove the carrying handle.

2. Remove the front and rear rubber bumpers.

Chapter 2 39
Making Your First Measurements
Rack Mounting the Test Set

3. Fit the Rack Mount Flanges.


(Parts available separately: 5063-9241).

Ready for installation.

40 Chapter 2
3 Regulatory Information

Chapter 3 41
Regulatory Information
General Specifications

General Specifications

Environmental

Operating 0oC to +55oC


Temperature

Storage - 20oC to +70oC


Temperature:

Humidity: Up to 95% Relative Humidity to +40oC

Altitude: 3000m (9,840 ft.)

EMC: Meets EN55011: 1991 (Group 1, Class A), and


EN50082- 1:1992.

Physical Specifications

Weight (Net): 6.82 Kg (Bluetooth option)

Dimensions: 105H x 370W x 390D mm nominal

Power Requirements

Line Input Voltage Range: 100 to 240 Vac,


Power: automatic selection
Input Frequency Range: 50 to 60 Hz

Power Requirement: 150 VA (max)

Cooling Requirements
To provide adequate cooling, and air gap of approximately 75mm (3ins)
should be maintained around the vented sections of the Test Set.

42 Chapter 3
Regulatory Information
General Specifications

Cleaning
Use a soft, clean, damp cloth to clean the front- panel and side covers.

Usage
This Test Set is designed for indoor use only.

WARNING Appliance coupler (mains input power cord) is the power disconnect
device. Do not position the Test Set such that access to the coupler
is impaired.

WARNING For continued protection against fire hazard, replace the line fuse
only with the same type and line rating (250V, F3.15A, 20mm fast
blow fuse with high breaking capacity, Agilent Part Number
2110- 0957).
The use of other fuses or materials is prohibited. Always disconnect
the Test Set from the mains supply before attempting to replace the
fuse.

WARNING No operator serviceable parts inside. Refer servicing to qualified


personnel. To prevent electrical shock do not remove covers.

WARNING If this Test Set is not used as specified, the protection provided by
the equipment could be impaired. This Test Set must be used in a
normal condition only (in which all means for protection are
intact).

CAUTION This Test Set is designed for use in Installation Category II and
Pollution Degree 2 per IEC61010 and 60664 respectively.

Chapter 3 43
Regulatory Information
Compliance and Markings

Compliance and Markings

Electromagnetic Compatibility (EMC)


This product conforms with the protection requirements of European
Council Directive 89/336/EEC for Electromagnetic Compatibility (EMC).
The conformity assessment requirements have been met using the
technical Construction file route to compliance, using EMC test
specifications EN 55011:1991 (Group 1, Class A) and EN 50082- 1:1992.
In order to preserve the EMC performance of the product, any cable
which becomes worn or damaged must be replaced with the same type
and specification.
Refer to the “Declaration of Conformity” on page 48.

10 Base- T LAN Connection Radiated Emissions:


To ensure compliance with EN 55011 (1991) a screened category 5,
STP patch lead (RJ45 cable) should be used to connect the LAN port.

Safety
This Test Set has been designed and tested in accordance with
publication EN61010- 1(2001) / IEC 1010- 1(2001) / CSA C22.2 No.
61010- 1- 04 Safety Requirements for Electrical Equipment for
Measurement, Control and Laboratory Use, and has been supplied in a
safe condition. The instruction documentation contains information
and warnings which must be followed by the user to ensure safe
operation and to maintain the Test Set in a safe condition.

44 Chapter 3
Regulatory Information
Compliance and Markings

Markings
The following markings can be found on the rear panel.

The CE mark shows that the product complies with all the
relevant European legal Directives.

ICES/NMB-001 This ISM device complies with Canadian ICES- 001.


Cet appareil ISM est conforme à la norme NMB- 001 du Canada.

The CSA mark is a registered trademark of the Canadian


Standards Association and indicates compliance to the standards
laid out by them.

GROUP 1 This is the symbol of an Industrial Scientific and Medical Group


ISM CLASS A
1 Class A product.

The C- Tick mark is a registered trademark of the Australian


Communications Authority. This signifies compliance with the
Australian EMC Framework Regulations under the terms of the
Radio communications Act of 1992.

External Protective Earth Terminal.

While this is a Class I product, provided with a protective


earthing conductor in a power cord, an external protective
earthing terminal has also been provided. This terminal is for
use where the earthing cannot be assured. At least an 18AWG
earthing conductor should be used in such an instance, to
ground the Test Set to an assured earth terminal.

Chapter 3 45
Regulatory Information
Compliance and Markings

This product complies with the WEEE Directive (2002/96/EC)


marking requirements. The affixed label indicates that you must
not discard this electrical / electronic product in domestic
household waste.
Product Category: With reference to the equipment types in the
WEEE Directive Annex I, this product is classed as a “Monitoring
and Control instrumentation” product.
Do not dispose in domestic household waste.
To return unwanted products, contact your local Agilent office or
see www.agilent.com/environmental/product/ for more information.

This is a USB symbol, and indicates a Univeral Serial Bus port or


ports.

46 Chapter 3
Regulatory Information
Regulatory Information

Regulatory Information

Sound Emission

Herstellerbescheinigung
Diese Information steht im Zusammenhang mit den Anforderungen der
Maschinenlarminformationsverordnung vom 18 Januar 1991.

• Sound Pressure LpA < 70dB.


• Am Arbeitsplatz.
• Normaler Betrieb.
Nach DIN 45635 T. 19 (Typprufung).

Manufacturers Declaration
This statement is provided to comply with the requirements of the
German Sound DIN 45635 T. 19 (Typprufung).

• Sound Pressure LpA 70 < dB.


• At operator position.
• Normal operation.
• According to ISO 7779 (Type Test).

Chapter 3 47
Regulatory Information
Declaration of Conformity

Declaration of Conformity

DECLARATION OF CONFORMITY
According to ISO/IEC Guide 22 and CEN/CENELEC EN 45014

DoC template
Manufacturer’s Name: Agilent Technologies UK Limited
Manufacturer’s Address: WBU Order Fulfillment
Supplier’s Address: Station Road
South Queensferry
West Lothian, EH30 9TG
Scotland, United Kingdom

Declares under sole responsibility that the product as originally delivered

Product Name: Wireless Connectivity Test Set


Model Number: N4010A
Product Options: This declaration covers all options of the above product as
detailed in TCF A-5951-9852-02.

complies with the essential requirements of the following applicable European Directives, and carries
the CE marking accordingly:

• The Low Voltage Directive 73/23/EEC, amended by 93/68/EEC


• The EMC Directive 89/336/EEC, amended by 93/68/EEC

As detailed in: Electromagnetic Compatibility (EMC)


Technical Construction File (TCF) No. TCF A-5951-9852-02.

Assessed by: DTI Appointed Competent Body


EMC Test Centre,
GEC-Marconi Avionics Ltd.,
Maxwell Building,
Donibristle Industrial Park,
Hillend,
Dunfermline
KY11 9LB
Scotland, United Kingdom

Technical Report Number: 6893/2201/CBR, dated 23 September 1997

EMC Test Specifications: EN 55011:1991 (Group 1, Class A) and EN 50082-1:1992.

and conforms with the following product standards:

Safety IEC 61010-1:2001 / EN 61010-1:2001


Canada: CAN/CSA-C22.2 No 1010.1-92
EMC Canada: ICES-001:1998
Australia/New Zealand: AS/NZS 2064.1

Supplementary Information:

This DoC applies to above-listed products placed on the EU market after:

28 January 2004
Date Robert Tait

Quality & Regulations Manager

For further information, please contact your local Agilent Technologies sales office, agent or distributor,
or Agilent Technologies Deutschland GmbH, Herrenberger Straße 130, D 71034 Böblingen, Germany.

48 Chapter 3
Regulatory Information
Responsibilities of the Customer

Responsibilities of the Customer


The customer shall provide:

• Access to the products during the specified periods of coverage to


perform maintenance
• Adequate working space around the products for servicing by
Agilent personnel.
• Access to and use of all information and facilities determined
necessary by Agilent to service and/or maintain the products.
(Insofar as these items may contain proprietary or classified
information, the customer shall assume full responsibility for
safeguarding and protection from wrongful use.)
• Routine operator maintenance and cleaning as specified in the
Agilent Operating and Service Manuals.
• Consumables such as replacement fuses, etc.

Chapter 3 49
Regulatory Information
Agilent Sales and Service Offices

Agilent Sales and Service Offices


In any correspondence or telephone conversations, refer to the Test
Set by its model number and full serial number. With this information,
the Agilent representative can quickly determine whether your unit is
still within its warranty period.

UNITED STATES Agilent Technologies


(tel) 1 800 829 4444

CANADA Agilent Technologies Canada Inc.


Test & Measurement
(tel) 1 877 894 4414

EUROPE Agilent Technologies


Test & Measurement
European Marketing Organization
(tel) (31 20) 547 2000

JAPAN Agilent Technologies Japan Ltd.


(tel) (81) 426 56 7832
(fax) (81) 426 56 7840

LATIN AMERICA Agilent Technologies


Latin America Region Headquarters, USA
(tel) (305) 267 4245
(fax) (305) 267 4286

AUSTRALIA and Agilent Technologies Australia Pty Ltd.


NEW ZEALAND (tel) 1- 800 629 4852 (Australia)
(fax) (61 3) 9272 0749 (Australia)
(tel) 0- 800 738 378 (New Zealand)
(fax) (64 4) 802 6881 (New Zealand)

ASIA PACIFIC Agilent Technologies, Hong Kong


(tel) (852) 3197 7777
(fax) (852) 2506 9284

You can visit our website: - http://www.agilent.com/find/assist.

50 Chapter 3

You might also like