Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Legrand Elsteel Switchboard

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

ELSTEEL

SWITCHBOARD
SOLUTIONS TO 4000 A
CRITICAL

Global
POWER
EXPERTS

strength
From cast resin transformers, through high power
and rising main busbar to protection devices and
uninterpretable power supplies - we provide market
leading solutions to the increasing demands of
today’s buildings.

built on local SUPPORT THROUGHOUT


YOUR PROJECT

knowledge When you work with us you’ll receive expert support at


every stage. Alongside our specialist sales and technical
support teams you’ll also benefit from:

• Bank of technical information and data sheets


Legrand transforms the spaces where on our website
people live, work and meet. • BIM files
We’re meeting the world’s technological, social and
• CPD seminars
environmental challenges by pursuing our purpose: to
improve lives with electrical and digital infrastructures • Drawings service
and connected solutions that are simple, innovative and
• Product Environmental Profiles (PEPs)
sustainable.
• Product training
Legrand in the UK and Ireland • Site visits
We have been manufacturing in the UK since 1980 and
our six manufacturing sites create mechanical, electrical,
electronic and digital solutions. At Legrand we are committed to
With specialist sales people who have a thorough improving lives and this means
understanding of your industry and our team of creating a more sustainable world
engineers on the road to help with project management, for everybody.
commissioning, maintenance and any post-build
challenges, we’re with you every step of the way. To achieve this, reducing our carbon footprint and
developing a circular economy approach within
our activities are our priorities. In addition, we are
committed to promoting diversity and inclusion,
while being a responsible business in our day-to-day UPDATE
relationships with all our stakeholders, especially our COPY
employees, customers and suppliers.

2 3
LV SWITCHBOARD A NEW GENERATION
BS EN 61439-2 ES006 Iss2 0

OF SWITCHBOARD 1 2 3

N L1 L2 L3
4 5

COMPACT DESIGN
6 7

THAT LEADS THE


F ISO A3 - 420x297mm
Third Angle Projection
ALU. Do not scale - If in doubt ask
FLAT FLAT
GLAND
COVER COVER

WAY IN ENERGY
PLATE 1. Interface & construction details
Rated voltage Un 415V
Rated insulation voltage Ui <1kV
Uimp

FEATURES
Rated impulse voltage 8kV

MANAGEMENT &
Rated frequency f 50Hz
Rated short-time current Icw kA #s
External paint colour RAL7035

• Rated normal current Up to 4000 A


Degree of protection IP ##

AUTOMATION
D Assembly design type Multi-cubicle
E Form of separation F/T 4a/2
Cable entry T/B Top/Bottom
Cable exit T/B Top/Bottom

• Rated voltage 415 V AC A B C


General access
2. Service environment
F/R Front

1 1 1 1
Installation method Stationary

200
Location type Indoor
• Rated frequency 50/60 Hz BLANK
External impact
Amb. air temp. limits
IK
°C
10
-5/+40
2 Amb. air-temp average °C 35

200
Relative humidity % 50%

• Forms of separation Form 4 Type 7 D DPX3 125 4P FIXED


Pollution degree
EMC environment A/B
3
A
3 External conductors Al/Cu Cu

200
Arcing classification A N/A

• Degree of protection IP43


Personnel access Authorised
DPX3 250 4P FIXED On\offshore installation Onshore
4 2 3. Busbar system & power distribution circuits

200
Phase orientations F-B L-R T-B N-L1-L2-L3

• Ambient temperature 40 degrees C 3


DPX 250 4P PLUG-IN
5
Insulated busbars
Tinned busbars
Y/N
Y/N
No
No
Dimensions (mm) : (1) (2)

200
Incoming circuit(s) 2x80x10 -
-
• Colour RAL 7035
Main busbars 2x60x10
C Distribution busbars 2x60x10 -
LEGRAND DMX3

2100
Protective circuit 2x10x10 TN-S
2000A 4P W/D ACB

200
Current ratings (A) : (1) (2)
MAIN INCOMER Incoming circuit(s) 2000A -

• Icc rating (A) 70 kA 6


3
DPX 400 4P FIXED Main busbars
Distribution busbars
2000A
2000A
-
-

200
4. Device current ratings

• Icw rating (A/Sec) 100 kA for 1 Second


These are detailed as per the OEM device
manufacturer's rated current value (In)
3 For the rated circuit current (Inc) please visit:
https://www.elsteel.com

200
B DPX3 400 4P FIXED
7 1 FOR CONSTRUCTION C.J 21/12/22
0

BENEFITS
FOR APPROVAL C.J 20/12/22

200
No. Issue Details By Date
Client
LEGRAND SNC

• Single or double stack options

200
Project Ref.
DPX3 630 4P FIXED 170309/MORA

• 800A, 1200A OR 1600A busbars Drawing Title


GENERAL ARRANGEMENT
600 600 200
• Form b separation with incoming A
1400
2250
800 600
650
DIAGRAM
-
-
and outgoing cables shrouded FRONT ELEVATION SIDE ELEVATION Drawing Ref.
TM 26467B-GAD-01

• High stacking density, up to 14 x THIS DRAWING IS CONFIDENTIAL AND IS SUPPLIED ON THE EXPRESS CONDITION THAT IT SHALL NOT BE COPIED OR DISCLOSED TO ANY THIRD PARTY WITHOUT THE PRIOR WRITTEN CONSENT OF ELSTEEL UK LTD. Contact details: Tel: +44(0)1978 855909 sales@elsteel.co.uk www.elsteel.co.uk Drn by: C.J Chk by: ENG. Iss. 1

160A TP MCCBs
• Plug and play metering
SPECIFICATION
• Type 1 or 2 surge arresters can be
Form of separation
fitted to the incomer
up to Form 4b or Form 4 Type 7
Our switchboard assemblies are ideal for commercial and
Degree of protection
IP43 (doors closed) industrial main circuit protection with Form ratings available
Busbar short-time withstand
up to Form 4B to IEC 61439-2, and Form 4 Type to BS
rating Icw 100 kA for 1 second EN 61439-2. The system is independently tested – ASTA
Busbar current rating Certificate 105492960 – to the latest version of IEV 61439-2.
Incoming 4000 A
The switchboard also has the facility to be supplied
Incomer types
Our products Switchboard assemblies offer ingress protection of up to
IP55 and form of separation up to Form 4 Type 7.
Legrand 4000 A 4P DMX3 –
with flanges for Zucchini busbar. Testing has proven the
suitability of Zucchini busbar in conjunction with the Elsteel
can be utilised in They are suitable for connection to busbar systems up to 4000
Fixed or withdrawable
Ratings/Poles switchboard and Legrand protection devices.
BS type fully verified Amps and certified for withstand up to 100 kA for 1 second. 25 – 1600 A outgoing MCCBs.
Choice of TM or Electronic trip
switchboard systems Independently verified in accordance with IEC / BS EN 61439-2.
units. Fixed or plug-in

4 5
SWITCHBOARD
SOLUTIONS TO

4000 A ACBs available to 4000 A

FRONT VIEW
Busbars rated
0 1 2 3 4 5 6 7
ES006 Iss2 0 1 2 3 4 5 0 6 1 7 2 3 4 5 6 7

F F
for 100 kA withstand
ISO A3 - 420x297mm
First angle projection ISO A3 - 420x297mm ISO A3 - 420x297mm
Do not scale - If in doubt ask First angle projection First angle projection
Do not scale - If in doubt ask Do not scale - If in doubt ask
NOTES:
Cross Bar Light. NOTES: NOTES:
Separation Plate.
Mesh Separation Plate.
PVC Separation Plate.
ALU Gland Plate.
INT Galv Back Plate.
E E Mesh PVC Separation Plate.
Arc Fault Separation Plate.
Mild Steel Gland Plate.

D D

C
C

2 CUSTOMER CHANGES C.J 26/01/2023


2 CUSTOMER CHANGES C.J 26/01/2023
2 CUSTOMER CHANGES C.J 26/01/2023
B 1 FOR CONSTRUCTION C.J 21/12/2022
1 FOR CONSTRUCTION C.J 21/12/2022
B 1 FOR CONSTRUCTION C.J 21/12/2022
0 FOR APPROVAL C.J 20/12/2022
0 FOR APPROVAL C.J 20/12/2022
No. Issue Details By Date 0 FOR APPROVAL C.J 20/12/2022
No. Issue Details By Date
No. Issue Details By Date
Client
Client
LEGRAND SNC LEGRAND SNC Client
LEGRAND SNC
Project ref. Project ref.
170309/MORA 170309/MORA Project ref.
170309/MORA
Drawing title Drawing title
FRONT CBS LAYOUT FRONT SEPARATION PLATE LAYOUT Drawing title
FRONT COVER LAYOUT
A
A

Drawing ref. Drawing ref.


TM26467B-CBS-F1 TM26467B-SEP-F1
Drawing ref.
TM26467B-COV-F1

Withdrawable or fixed ACBs and plug-in


DRAWING IS CONFIDENTIAL AND IS SUPPLIED ON THE EXPRESS CONDITION THAT IT SHALL NOT BE COPIED OR DISCLOSED TO ANY THIRD PARTY WITHOUT THE PRIOR WRITTEN CONSENT OF ELSTEEL UK LTD. Contact details: Tel:
THIS DRAWING +44(0)1978 855909
IS CONFIDENTIAL sales@elsteel.co.uk
AND IS www.elsteel.co.uk
SUPPLIED ON THE EXPRESS DrnIT by:
CONDITION THAT SHALLC.J Chk by: OR
NOT BE COPIED ENG. Iss. TO
DISCLOSED 2 ANY THIRD PARTY WITHOUT THE PRIOR WRITTEN CONSENT OF ELSTEEL UK LTD. Contact details: Tel: +44(0)1978 855909 sales@elsteel.co.uk www.elsteel.co.uk Drn by: C.J Chk by: ENG. Iss. 2
THIS DRAWING IS CONFIDENTIAL AND IS SUPPLIED ON THE EXPRESS CONDITION THAT IT SHALL NOT BE COPIED OR DISCLOSED TO ANY THIRD PARTY WITHOUT THE PRIOR WRITTEN CONSENT OF ELSTEEL UK LTD. Contact details: Tel: +44(0)1978 855909 sales@elsteel.co.uk www.elsteel.co.uk Drn by: C.J Chk by: ENG. Iss. 2

or fixed MCCBs

REAR VIEW
0 1 2 3 4 5 6 7
ES006 Iss2 0 1 2 3 4 5 0 6 1 7 2 3 4 5 6 7

F F

ISO A3 - 420x297mm
First angle projection ISO A3 - 420x297mm ISO A3 - 420x297mm
Do not scale - If in doubt ask First angle projection First angle projection
Do not scale - If in doubt ask Do not scale - If in doubt ask
NOTES:
NOTES: NOTES:
Cross Bar Light. Separation Plate.
Mesh Separation Plate.
PVC Separation Plate.
ALU Gland Plate.
INT Galv Back Plate.
E E Mesh PVC Separation Plate.
Arc Fault Separation Plate.
Mild Steel Gland Plate.

D D

C
C

2 CUSTOMER CHANGES C.J 26/01/2023


2 CUSTOMER CHANGES C.J 26/01/2023
2 CUSTOMER CHANGES C.J 26/01/2023
B 1 FOR CONSTRUCTION C.J 21/12/2022
1 FOR CONSTRUCTION C.J 21/12/2022
B 1 FOR CONSTRUCTION C.J 21/12/2022
0 FOR APPROVAL C.J 20/12/2022

Glanding boxes available for all outgoing devices


0 FOR APPROVAL C.J 20/12/2022
No. Issue Details By Date 0 FOR APPROVAL C.J 20/12/2022
No. Issue Details By Date
No. Issue Details By Date
Client
Client
LEGRAND SNC LEGRAND SNC Client
LEGRAND SNC
Project ref. Project ref.
170309/MORA 170309/MORA Project ref.
170309/MORA
Drawing title Drawing title
REAR CBS LAYOUT REAR SEPARATION PLATE LAYOUT Drawing title
REAR COVER LAYOUT
A
A

Drawing ref. Drawing ref.

Rotary handles available for all MCCBs


TM26467B-CBS-R1 TM26467B-SEP-R1
Drawing ref.

DRAWING IS CONFIDENTIAL AND IS SUPPLIED ON THE EXPRESS CONDITION THAT IT SHALL NOT BE COPIED OR DISCLOSED TO ANY THIRD PARTY WITHOUT THE PRIOR WRITTEN CONSENT OF ELSTEEL UKTHIS
LTD. ContactISdetails: Tel: +44(0)1978
TM26467B-COV-R1
DRAWING CONFIDENTIAL AND IS855909 sales@elsteel.co.uk
SUPPLIED www.elsteel.co.uk
ON THE EXPRESS CONDITION THAT IT SHALLDrn
NOTby: C.J
BE COPIED Chk
OR by: ENG.TO ANY
DISCLOSED Iss. THIRD
2 PARTY WITHOUT THE PRIOR WRITTEN CONSENT OF ELSTEEL UK LTD. Contact details: Tel: +44(0)1978 855909 sales@elsteel.co.uk www.elsteel.co.uk Drn by: C.J Chk by: ENG. Iss. 2
THIS DRAWING IS CONFIDENTIAL AND IS SUPPLIED ON THE EXPRESS CONDITION THAT IT SHALL NOT BE COPIED OR DISCLOSED TO ANY THIRD PARTY WITHOUT THE PRIOR WRITTEN CONSENT OF ELSTEEL UK LTD. Contact details: Tel: +44(0)1978 855909 sales@elsteel.co.uk www.elsteel.co.uk Drn by: C.J Chk by: ENG. Iss. 2

6 7
PROTECTION
DMX3: ACCURACY AND SIMPLICITY

Electronic protection units allow accurate

DEVICES
adjustment of the various limits for current and
time delay values. The result is effective protection
against electrical failures while ensuring total
selectivity with the downstream circuit breakers.

Fitted with batteries, they are used to monitor


parameters and memorise data, even if the circuit
breaker is de-energised. Thanks to the LCD display,
measured current values can be monitored and
incorrect adjustments logged.

A COMPLETE
PORTFOLIO FOR
ANY INSTALLATION
Legrand offers ACBs, MCCBs and other
protection devices, for complete circuit DPX3 & DPX3 HP: RELIABLE
protection, operator safety, energy
efficiency and reliability in critical power
PROTECTION AND MEASUREMENT
environments.
Suitable for all types of site, the DPX³ range
includes four sizes of MCCB, for ratings
between 16 A and 1600 A and breaking
capacities ranging from 16 to 100 kA.

It also offers a wide choice of versions to suit


all requirements:
• Thermal-magnetic or electronic releases
FEATURES
• according to the required level of protection
DMX3 ACBs 630 A to 6300 A DPX3 & DPX3 HP MCCBs from 160 A to 1600 A • Fixed, withdrawable and plug-in devices •
• Four breaking capacities: • Four breaking capacities: according to the required level of maintenance
42 kA, 50 kA, 65 kA and 100 kA 36 kA, 50 kA, 70 kA and 100 kA
• All DMX3 breakers are factory equipped • Thermal magnetic and electronic
with protection units and option for embedded energy
measurement Options available include:
• Innovative and user-friendly touch screen • 3 or 4 pole options DX³: ADVANCED PROTECTION
tripping units • Optional integrated metering
• Full range of fast clip control accessories • Fixed, plug in or withdrawable options and Packed with innovative functions and
earth leakage protection technical features, the DX³ range meets the
needs of the most demanding residential,
commercial and industrial installations in
terms of safety, performance and selectivity.
KEY BENEFITS
Comprising MCBs, RCBOs, RCCBs and
• Circuit protection selectivity between DPX3/DMX3 electronic circuit breakers add-on modules, the DX³ range ensures
• Full compliance with EN/IEC standard 60947-2 and 60947-3 the safety of people and property as well as
• Compliant with European Directives REACh and ROHS and PEPs maximum continuity of service.
(Product Environmental Profile) available To find out more visit: legrand.co.uk
8 9
CRITICAL
CAST RESIN TRANSFORMERS

A COMPLETE Green T.HE transformers guarantee a


significant reduction in energy consumption,

SOLUTION POWER
promoting enhanced economic savings and
the reduction of CO2 emissions into the
atmosphere.

HIGH POWER BUSBAR

FOR LV POWER DISTRIBUTION Ranging from 630-6300 amps, our high


power busbar is characterised by a smart and
Switchboards ultra-compact design that delivers up to an
IP68 degree of protection.
Verified and protection
switchboard
tested with busbar
devices UPS
and protection

BUILT FOR devices Legrand’s UPS range offers a variety of


Pre-engineered technological functions to guarantee
connections for maximum protection and uptime for all
RELIABILITY transformer
to busbar
systems.

Legrand’s advanced technology solutions


are proven to deliver excellent reliability DMX3 AIR CIRCUIT BREAKERS
and service. & DPX3 MOULDED CASE
Busbar CIRCUIT BREAKERS
With a complete package from a trusted,
global manufacturer, products that are designed The right protection for your high-performance
to work together and support throughout each installations with an optimum continuity of
stage of your project, service.
we can provide a power distribution system
that is reliable, efficient and meets bespoke
requirements.

All Legrand products are built with superior To find out more about
design and quality manufacturing and are energy efficiency To find out more visit:
delivered with service excellence to meet the
demanding requirements of any building.
solutions take our CPD
‘Creating an energy Systems available
UPS
efficient electrical to 4000 A
backbone’.

Cast resin Visit to find out more:


legrand.co.uk/cpd
transformers www.legrand.co.uk/en/solutions/low-voltage-solutions

ALL THE
EQUIPMENT
YOU NEED IMAGE
A complementary range of products and
accessories can be found on our website:
SPACE
legrand.co.uk

10 11
Contact details
Quotations and Technical Support:
Legrand Electric Ltd.
Great King Street North,
Birmingham, B19 2LF
Tel: +44 (0) 370 608 9020
E-mail: powersales.uk@legrand.co.uk
Customer Services:
Tel: +44 (0) 345 605 4333
E-mail: powersales.uk@legrand.co.uk

FOLLOW
US AT
www.legrand.co.uk
www.legrand.ie
www.youtube.com/legrandtvuk

www.twitter.com/legranduk
www.linkedin.com/
company/legranduk

Switchboard solutions 03/2024

Head office (UK and Ireland):


Legrand Electric Limited
Great King Street North, Birmingham, B19 2LF
Tel: +44 (0) 370 608 9000
Website: www.legrand.co.uk

In accordance with its policy of continuous improvement, the Company


reserves the right to change specifications and designs without notice.
All illustrations, descriptions, dimensions and weights in this catalogue
are for guidance and cannot be held binding on the Company. All
contents and design presentation included in this publication are ©
Legrand Electric Limited. All rights reserved. 2024

The Legrand logo is a registered trademark


This document is printed on sustainably sourced paper. Please recycle. of the Legrand group of companies.

You might also like