Elkay EZ Install
Elkay EZ Install
Elkay EZ Install
Enhanced
INSTALLATION & USE MANUAL
Patent zurn-elkay.com/patents
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
C
L
3 1/2"
6 3/8" 6 3/8" 90mm
ACTIVATION
2 7/8"
38 1/2" 73mm
979mm 2" 2"
51mm 51mm
B
E E 32 7/8" 2"
835mm 8 1/16" 51mm
FILTER ORIFICE
HEIGHT 205mm
A
D
28 13/16"
731mm 31 5/16"
28 13/16" 796mm C
731mm 3"
21 7/8" RIM 76mm
Page 2
HEIGHT
Fig. 1
556mm
WATER
FILTER
ENLZS8WS_1G
27"
19" 686mm
2" ADA 5 7/8"
483mm 149mm
51mm REQUIREMENT
F
3 7/8"
98mm 13 15/16"
17 7/16" 354mm 12 1/2"
5 3/4" 318mm
443mm 146mm
7" 7"
178mm 178mm
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY
OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN STUB 2 IN. OUT FROM WALL
C = 1-1/4" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET**
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
NOTE: IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR
20 AMPS.
ENLZS8WS_1G
1) Remove lower cover on cooler by removing (4) screws (See Fig.7, Pg. 5).
2) Turn off water supply; dispense water to relieve pressure.
3) Remove power by unplugging cooler.
4) Turn used filter counterclockwise 1/4 turn to remove from filter head.
5) Remove cap from new filter and use to seal used filter.
6) Insert new filter into existing filter head and turn fully clockwise. Make sure you can read the label on the front of the filter once it is installed. (See Fig.11, Pg. 7).
7) Plug in unit to restore power.
8) Turn on water supply and run a minimum of two gallons of water through the filter to purge air any fine carbon particles from filter. Also run water through bottle filler
Note: Filter status light will automatically reset once new filter is installed.
Programming Button
FIG. A
Instructions To Access Programming Button
1) Remove lower cover on refrigerated unit by removing (4) screws (See Fig 7, Pg 5).
2) Button is located in lower right corner of unit (See Fig. A, Pg. 3).
Secure cooler frame to wall by installing (2) screws and washers (not supplied).
FIG. 2 FIG. 3
Lay gasket along back of bottle filler mounting plate. Align BF and lay on cooler basin.
Fig. 4
Fig. 7
32
31
MOUNTING BOLT HOLES (6)
33
34
31
33
36 35
27
28
25
Fig. 9
WARNING
• INGESTION HAZARD: This product contains a button cell or coin battery.
• DEATH or serious injury can occur if ingested.
• A swallowed button cell or coin battery can cause Internal Chemical
Burns in as little as 2 hours.
• KEEP new and used batteries OUT OF REACH of CHILDREN
• Seek immediate medical attention if a battery is suspected to be
swallowed or inserted inside any part of the body.
A
A B C
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
Fig. 10
11
Basin
Locknut
BUBBLER DETAIL
Fig. 11
NOTE:
When installing replacement bubbler and pedestal, tighten nut only to hold parts
snug in position. Do Not Overtighten.
3/8”
Water
Inlet
Scan for trouble shooting and to sign up for
auto replenishment of authentic Elkay filters.
2
1
Fig. 12
Filter Detail
FILTER PARTS LIST
Service Instructions
Lower and Upper Shroud
To access the refrigeration system and plumbing connections, remove four screws from bottom
of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars,
regulator, solenoid valve or other components located in the top of the unit, remove lower shroud,
disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two
wires and water tube.
11
Bubbler
To remove the bubbler, first disconnect the power supply. The underside of the bubbler can be
reached through the access panel on the underside of the upper shroud. Remove the access
panel by removing the retaining screw. To remove the bubbler, loosen locknut from the underside
of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick
Connect Fittings section in the General Instructions. After servicing, replace the access panel
and retaining screw. 22
Switches Behind the Push Bar
The regulator in an EZ cooler is always held fully open by the use of a single regulator nut (See 2
Item 9, Fig. 14). Water is not dispensed until the pushbar is depressed to activate a switch which
then opens a solenoid valve.
To remove sidebars, from the inside compress the flared tabs and pull out carefully. To reinstall
side pushbars, the front of the pushbar is inserted first. While keeping the switch depressed,
snap the rear of the pushbar into position.
11 22
Cleaning
Stainless Steel 8
• General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
• Steel soap pads should never be used; particles can adhere to a stainless steel basin
surface and will eventually rust.
• Light scratches are normal for stainless steel basins; over time they will blend into the
uniform finish pattern.
Plastic Components 19
• General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
• Wiping the surface clean to remove debris or build up will not hurt the antimicrobial
properties.
6 9
12, 13
Temperature Control
• Factory set at 50°F (+/- 5°F) under normal conditions. For temperature adjustments, refer to
sticker on left side of top bar.
12
REGULATOR
Stream Height Adjustment ASSEMBLY
VIEW OF UNDERSIDE OF BASIN SHROUD
ALIGNMENT
NOTCH
SNAP
SNAP
Fig. 13
Cycles thru main menu items 2 seconds each for 2 cycles then exits menu unless selected
Cycles thru sub menu items 2 seconds each for 2 cycles then returns to main menu unless selected
Top level Action Sub Menu 1 Action Sub Menu/action Action Sub Menu/ Action Sub Menu/ Notes End Action
action action
Info Momentary Scrolls through all the settings Returns to Main Menu
on unit
Day (Sunday-Saturday Momentary Use push button to select the day on the display Drops to next level when selected
AM/PM Momentary Use push button to select AM or PM Drops to next level when selected
Hour (12 hour) Momentary Use push button to select Hour Drops to next level when selected
Min 0-69 in 5 minute increments Momentary Use push button to select closest minute Returns to Main Menu
No Momentary Turn off filter status and erros No Filter unit - Error codes related to filter status Returns to Main Menu
turned off
Yes Momentary Default setting - Turn on filter status and errors Filter status has default ON / Default has read write Returns to Main Menu
to filter, LED status display, filter error capability
No Momentary Turns off power to E/S relay sets bottle fill time to 1.5gpm Refrigeration off Returns to Main Menu
Page 9
Yes Momentary Default setting - Turns on power to E/S relay - sets time to Refrigeration on Returns to Main Menu
1.1gpm
ENLZS8WS_1G
Range Momentary The lower the number, the closer to the sensor the Drops to next level when selected
bottle needs to be to activate
1-10 Momentary Default setting 5 - Adjusts distance from sensor the bottle needs Returns to Main Menu
to be before turning before turning on or off the bottle filler
B-Light Momentary The settings are for the brightness of the display Drops to next level when selected
and night light
On Momentary Set Energy Save Schedule Drops to next level when selected
Momentary Select time on 24 hours – 1-12AM and 1-12PM Drops to next level when selected
Momentary Select time off 24 hours – 1-12AM and 1-12PM Drops to next level when selected
Momentary Select time on 24 hours – 1-12AM and 1-12PM Drops to next level when selected
Momentary Select time off 24 hours – 1-12AM and 1-12PM Returns to Main Menu
1 21
Filter Location
15
23
26
6
5
See Fig. 12
12 or 13 3
2
See Fig. 14
12
12
19
16
29
21, 24
10
7
18
30
20
19 4 19
17
Fig. 14
Page 11 1000004538 (Rev. F - 03/24)
ENLZS8WS_1G
BOTTLE FILLER
REPLACEMENT PART KITS
ITEM PART NO. DESCRIPTION
NO.
NS 98546C Kit - Aerator Replacement
30 98549C Kit - Hardware & Waterway (BF)
31 1000004573 Kit - Solenoid 120V (BF)
NS 1000005077 Nameplate - Elkay Filtered
32 1000002433 Kit - Top Cover Assy (BF)
33 1000005219 Kit - IR Sensor K+
34 1000004544 Kit - Alpha Numeric LED Board
NS 1000004436 Kit - Tower/Basin Gasket
35 1000004546 Harness - Bottle Filler
36 1000004549 Harness - LED/IR Board
NS = Not Shown
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de license. L’exploitation est autorisée aux deux conditions
suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.