You are on page 1of 12

ENLZS8WS_1G

Enhanced
INSTALLATION & USE MANUAL

LZ ™ Series Bottle Filling Stations & Coolers

Patent zurn-elkay.com/patents
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

Page 1 1000004538 (Rev. F - 03/24)


18"
458mm
7" 7"
178mm 178mm

7/16" X 3/4" (11mm X 19mm)


OBROUND HOLES (6)

C
L
3 1/2"
6 3/8" 6 3/8" 90mm
ACTIVATION

1000004538 (Rev. F - 03/24)


51 9/16" 162mm 162mm
SENSOR
1310mm 19"
15" 483mm
381mm 19"
482mm

Ø 9/32" (7mm) HANGER


HOLES (9) BRACKET

2 7/8"
38 1/2" 73mm
979mm 2" 2"
51mm 51mm

B
E E 32 7/8" 2"
835mm 8 1/16" 51mm
FILTER ORIFICE
HEIGHT 205mm
A
D
28 13/16"
731mm 31 5/16"
28 13/16" 796mm C
731mm 3"
21 7/8" RIM 76mm

Page 2
HEIGHT

Fig. 1
556mm
WATER
FILTER
ENLZS8WS_1G

27"
19" 686mm
2" ADA 5 7/8"
483mm 149mm
51mm REQUIREMENT
F
3 7/8"
98mm 13 15/16"
17 7/16" 354mm 12 1/2"
5 3/4" 318mm
443mm 146mm
7" 7"
178mm 178mm

PISO ACABADO SOL FINI FINISHED FLOOR

REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDREN’S ADA COOLER

LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY
OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN STUB 2 IN. OUT FROM WALL
C = 1-1/4" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET**
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
NOTE: IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR
20 AMPS.
ENLZS8WS_1G

HANGER BRACKET INSTALLATION


1) Remove hanger bracket fastened to back of cooler by removing one (1) screw.
2) Mount the hanger bracket as shown in Figure 1 (Pg. 2).
NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six
(6) 1/4 in. dia. mounting holes.
IMPORTANT: 5-7/8 in. (150mm) dimension from wall to centerline of trap must be maintained for proper fit.
INSTALLATION OF COOLER
3)Hang the cooler on the hanger bracket. Be certain hanger bracket is engaged properly in the slots on the cooler back as shown in Figure 1 (Pg. 2).
4)Remove the four (4) screws holding the lower front panel at the bottom of the cooler (See Fig 7, Pg.5). Remove the front panel by pulling straight down and set aside.
5)Secure cooler frame to wall by installing (2) screws and washers (not supplied). (See Fig. 2, Pg. 4). Make sure the screws engage in a structural member.
6)Connect the supply water to the filter inlet tube.
7)Install trap. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap. Assemble the slip nut
and gasket to the trap and tighten securely.
IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.

BOTTLE FILLER INSTALLATION


8) Remove two (2) mounting screws with 5/32" Allen wrench holding bottle filler to wall mounting plate (See Fig.8, Pg. 5). Note do not discard mounting screws, they will be
needed to secure bottle filler to wall mounting plate.
9) Remove wall mounting plate from Bottle Filler (see Fig 8, Pg. 5). Place wall mounting plate against wall on top of basin. Center the wall mounting plate side to side with the basin. Mark the
six (6) mounting holes with a pencil. Place tape over wiring harnes conection on top of cooler to prevent debris from falling into Connection.
10) Remove wall mounting plate from wall. NOTE: Mounting plate MUST be supported securely. Add fixture support carrier if wall will not provide adequate support.
11) Install wall mounting plate to wall using six (6) 7/16" obround mounting holes (mounting bolts not included) (See Fig.8, Pg. 5). Use appropriate fasteners for your wall type.
12) Install gasket on bottom of bottle filler tower with gasket support bracket & (2) screws. (See Fig. 4, Pg. 4).
13) Route 3/8” tubing through the opening in the bottle filler gasket and plug into bulkhead fitting in basin. Route the wiring harness through the
gasket and plug into the connector on the top of the basin.
14) Place bottle filler on four (4) hooks on the mounting plate installed on wall. Make sure round boss in gasket fits in hole of basin. (See Fig. 8, Pg. 5).
15) Plug electrical cord into outlet on wall.
16) Remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise. Ensure that blue label can be read when
filter is installed. (See Fig. 11, Pg. 7).
17) Turn water supply on and inspect for leaks. In both cooler and bottle filler. Fix all leaks before continuing.
18) Once cooler and bottle filter has been inspected for leaks and any leaks found corrected.
19) Reinstall two mounting screws from first step (See Fig. 8, Pg. 5). Caution, do not over tighten screws.
20) Once power is applied to the cooler the GREEN LED light will illuminate on the bottle filler showing good filter status along with the LCD Bottle Counter.
21) Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. Note: the first initial dispenses might have air in line
which may cause a sputter. This will be eliminated once all air is purged from the line.
22) Once unit tests out, install Lower Panel back on water cooler(s). Units are now ready for use.

Instructions For Replacing Filters

1) Remove lower cover on cooler by removing (4) screws (See Fig.7, Pg. 5).
2) Turn off water supply; dispense water to relieve pressure.
3) Remove power by unplugging cooler.
4) Turn used filter counterclockwise 1/4 turn to remove from filter head.
5) Remove cap from new filter and use to seal used filter.
6) Insert new filter into existing filter head and turn fully clockwise. Make sure you can read the label on the front of the filter once it is installed. (See Fig.11, Pg. 7).
7) Plug in unit to restore power.
8) Turn on water supply and run a minimum of two gallons of water through the filter to purge air any fine carbon particles from filter. Also run water through bottle filler
Note: Filter status light will automatically reset once new filter is installed.

Programming Button

FIG. A
Instructions To Access Programming Button
1) Remove lower cover on refrigerated unit by removing (4) screws (See Fig 7, Pg 5).
2) Button is located in lower right corner of unit (See Fig. A, Pg. 3).

Page 3 1000004538 (Rev. F - 03/24)


ENLZS8WS_1G

Secure cooler frame to wall by installing (2) screws and washers (not supplied).

FIG. 2 FIG. 3

Lay gasket along back of bottle filler mounting plate. Align BF and lay on cooler basin.
Fig. 4

Attach the 3/8 water line into the bulkhead fitting.


(Gasket removed from bottle filler for clarity)
Fig. 5
1000004538 (Rev. F - 03/24) Page 4
ENLZS8WS_1G

Fig. 7

Connect the bottle filler electrical harness.


(Gasket removed from bottle filler for clarity)
Fig. 6

32

31
MOUNTING BOLT HOLES (6)

33

WALL MOUNTING PLATE

BOTTLE FILLING UNIT


Fig. 8

Page 5 1000004538 (Rev. F - 03/24)


ENLZS8WS_1G

115V Refrigerated Wiring Diagram


with Alpha/Numeric Display

34
31

33

36 35
27

28

25

Fig. 9

WARNING
• INGESTION HAZARD: This product contains a button cell or coin battery.
• DEATH or serious injury can occur if ingested.
• A swallowed button cell or coin battery can cause Internal Chemical
Burns in as little as 2 hours.
• KEEP new and used batteries OUT OF REACH of CHILDREN
• Seek immediate medical attention if a battery is suspected to be
swallowed or inserted inside any part of the body.

OPERATION OF QUICK CONNECT FITTINGS


OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH
SIMPLY PUSHIN
IN TUBE
TUBEISIS SECURED
SECURED PUSH
PUSHIN
IN COLLET
COLLET
TUBE TO
TUBE TOATTACH
ATTACH INPOSITION
IN POSITION TORELEASE
TO RELEASE TUBE
TUBE
A

A
A B C
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
Fig. 10

1000004538 (Rev. F - 03/24) Page 6


ENLZS8WS_1G

11

Basin

Locknut

BUBBLER DETAIL

Fig. 11

NOTE:
When installing replacement bubbler and pedestal, tighten nut only to hold parts
snug in position. Do Not Overtighten.

3/8”
Water
Inlet
Scan for trouble shooting and to sign up for
auto replenishment of authentic Elkay filters.
2
1

Fig. 12

Filter Detail
FILTER PARTS LIST

ITEM NO. PART NO. DESCRIPTION


1 51300C Filter Assy - 3000 Gal.
2 1000005214 Kit - Filter Head Fittings includes
John Guest Fittings & 3/8” Elbow
Filter Bracket/Screws
3 1000004409 Kit - NFC Board/Cover

Page 7 1000004538 (Rev. F - 03/24)


ENLZS8WS_1G

Service Instructions
Lower and Upper Shroud
To access the refrigeration system and plumbing connections, remove four screws from bottom
of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars,
regulator, solenoid valve or other components located in the top of the unit, remove lower shroud,
disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two
wires and water tube.
11
Bubbler
To remove the bubbler, first disconnect the power supply. The underside of the bubbler can be
reached through the access panel on the underside of the upper shroud. Remove the access
panel by removing the retaining screw. To remove the bubbler, loosen locknut from the underside
of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick
Connect Fittings section in the General Instructions. After servicing, replace the access panel
and retaining screw. 22
Switches Behind the Push Bar
The regulator in an EZ cooler is always held fully open by the use of a single regulator nut (See 2
Item 9, Fig. 14). Water is not dispensed until the pushbar is depressed to activate a switch which
then opens a solenoid valve.

To remove sidebars, from the inside compress the flared tabs and pull out carefully. To reinstall
side pushbars, the front of the pushbar is inserted first. While keeping the switch depressed,
snap the rear of the pushbar into position.

11 22
Cleaning
Stainless Steel 8
• General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
• Steel soap pads should never be used; particles can adhere to a stainless steel basin
surface and will eventually rust.
• Light scratches are normal for stainless steel basins; over time they will blend into the
uniform finish pattern.
Plastic Components 19
• General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
• Wiping the surface clean to remove debris or build up will not hurt the antimicrobial
properties.

6 9
12, 13
Temperature Control
• Factory set at 50°F (+/- 5°F) under normal conditions. For temperature adjustments, refer to
sticker on left side of top bar.
12
REGULATOR
Stream Height Adjustment ASSEMBLY
VIEW OF UNDERSIDE OF BASIN SHROUD
ALIGNMENT
NOTCH

SNAP

SNAP

Stream Height Adjustment Location ALIGNMENT


PEG

Fig. 13

1000004538 (Rev. F - 03/24) Page 8


Programming Instruction
Depress Button for 3 seconds to activate main menu - release

Cycles thru main menu items 2 seconds each for 2 cycles then exits menu unless selected

Cycles thru sub menu items 2 seconds each for 2 cycles then returns to main menu unless selected

Selections are saved when the menu is exited

Top level Action Sub Menu 1 Action Sub Menu/action Action Sub Menu/ Action Sub Menu/ Notes End Action
action action
Info Momentary Scrolls through all the settings Returns to Main Menu
on unit

Info Momentary Flashes error code Returns to Main Menu

Set time Momentary Drops to next level when selected

Day (Sunday-Saturday Momentary Use push button to select the day on the display Drops to next level when selected

AM/PM Momentary Use push button to select AM or PM Drops to next level when selected

Hour (12 hour) Momentary Use push button to select Hour Drops to next level when selected

Min 0-69 in 5 minute increments Momentary Use push button to select closest minute Returns to Main Menu

Filter Momentary Drops to next level when selected

No Momentary Turn off filter status and erros No Filter unit - Error codes related to filter status Returns to Main Menu
turned off

Yes Momentary Default setting - Turn on filter status and errors Filter status has default ON / Default has read write Returns to Main Menu
to filter, LED status display, filter error capability

Refrig Momentary Drops to next level when selected

No Momentary Turns off power to E/S relay sets bottle fill time to 1.5gpm Refrigeration off Returns to Main Menu

Page 9
Yes Momentary Default setting - Turns on power to E/S relay - sets time to Refrigeration on Returns to Main Menu
1.1gpm
ENLZS8WS_1G

Range Momentary The lower the number, the closer to the sensor the Drops to next level when selected
bottle needs to be to activate

1-10 Momentary Default setting 5 - Adjusts distance from sensor the bottle needs Returns to Main Menu
to be before turning before turning on or off the bottle filler

B-Light Momentary The settings are for the brightness of the display Drops to next level when selected
and night light

25% Momentary Returns to Main Menu

50% Momentary Returns to Main Menu

75% Momentary Default Setting Returns to Main Menu

100% Momentary Returns to Main Menu

EnerSave Momentary Drops to next level when selected

Off Momentary Default Setting Returns to Main Menu

On Momentary Set Energy Save Schedule Drops to next level when selected

Select Weekday Drops to next level when selected

Momentary Select time on 24 hours – 1-12AM and 1-12PM Drops to next level when selected

Momentary Select time off 24 hours – 1-12AM and 1-12PM Drops to next level when selected

Select Weekend Drops to next level when selected

Momentary Select time on 24 hours – 1-12AM and 1-12PM Drops to next level when selected

Momentary Select time off 24 hours – 1-12AM and 1-12PM Returns to Main Menu

1000004538 (Rev. F - 03/24)


ENLZS8WS_1G

Enhanced EZH2O Error Codes


Error Error Description Corrective Action
Code
Bottle filler area obstructed • Remove obstruction.
• Clean lens on IR sensor
• Unplug unit for at least 30 seconds and restart
• If error repeats, replace IR sensor
E013 Missing or Incomplatible Filter • Check that filter is installed correctly (label facing forward, white tag fac-
ing back)
• Unplug unit for at least 30 seconds and restart
• Replace filter
• Replace filter head assembly with repair kit
• If error repeats, contact certified service professional
E013 & Missing NFC Board • Unplug unit for at least 30 seconds and restart
E014
• Verify cable connector is plugged into NFC board on filter head assembly
• Replace filter head assembly with repair kit
• If error repeats, contact certified service professional

1000004538 (Rev. F - 03/24) Page 10


ENLZS8WS_1G

Pictured is unit only without bottle filler.


Note: Danger! Electrical shock hazard. Disconnect power before serviceing unit.

Uses HFC-134A refrigerant 14

1 21

Filter Location
15

23

26
6
5
See Fig. 12
12 or 13 3
2
See Fig. 14

12
12

19
16
29
21, 24

10
7
18

30

20
19 4 19
17

Fig. 14
Page 11 1000004538 (Rev. F - 03/24)
ENLZS8WS_1G

115V PARTS LIST ATTENTION:


ITEM PART If the product serial number is before 190424189, please refer to archived
DESCRIPTION documents section of Elkay.com for the most accurate parts list.
NO. NO.
1
(www.elkay.com/archived-documents)
28401C Hanger Bracket
2 0000001337 Basin - Stainless Steel
3 36216C Wiring - Front/Side Push Bar
*4 36322C Compr - Service Pak 115V EMIS70HHR
5 56092C Tube - Poly (72”)
6 56229C Assy - Shroud - Upper (Front Side Push)
7 66703C Drier
8 1000001877 Kit - Drain Replacement (Bottle Filler) (Bracket, Tube, Fitting, Clamp)
9 1000004564 Kit - Regular/Holder/Nut
10 1000004572 Kit - Solenoid Valve/Regulator Assembly
11 56073C Kit - Flexi Bubbler/“O”-Ring/Nut
12 98734C Kit - Pushbar (Front/Side) EZS TL
13 1000001600 Kit - Pushbar (Front Only)
14 1000004568 Power Cord
15 98775C Kit - Fan Motor/Blade/Screws/Nut
16 98776C Kit - Condenser/Drier/Wire Ties
17 98777C Kit - Compr Mtg Hdwe/Grommets/Clips/Studs
18 98778C Kit - Heatx/Drier
19 98898C Kit - Hardware
20 0000000238 Kit - 115V Electricals (Relay, Overload, Cover)
21 98724C Kit - Evap. Replacement
22 1000001812 Kit - Bottle Filler Drain
23 56237C Shroud
24 1000001602 Kit - 75583C Elbow 5/16" x 1/4" (3 Pack)
25 1000004559 Wire Assy - Jumper
26 56213C Access Panel
27 1000004547 Harness - Cooler
28 1000004550 Wire - 6” Jumper
29 98773C Kit - Cold Control
NS 27416C Wrapper Stainless Steel
NS 27413C Wrapper Light Grey

NS = Not Shown * I N C L U D E S R E L AY & O V E R L O A D . I F


UNDER WARRANTY, REPLACE WITH SAME
COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the
above water coolers or orders for repair parts MUST
include Model No. and Serial No. of cooler, name and
part number of replacement part.

BOTTLE FILLER
REPLACEMENT PART KITS
ITEM PART NO. DESCRIPTION
NO.
NS 98546C Kit - Aerator Replacement
30 98549C Kit - Hardware & Waterway (BF)
31 1000004573 Kit - Solenoid 120V (BF)
NS 1000005077 Nameplate - Elkay Filtered
32 1000002433 Kit - Top Cover Assy (BF)
33 1000005219 Kit - IR Sensor K+
34 1000004544 Kit - Alpha Numeric LED Board
NS 1000004436 Kit - Tower/Basin Gasket
35 1000004546 Harness - Bottle Filler
36 1000004549 Harness - LED/IR Board

NS = Not Shown

FCC COMPLIANCE STATEMENT


CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment
This device complies with Part 15 of the FCC Rules. Operation to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation

INDUSTRY CANADA STATEMENT


This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de license. L’exploitation est autorisée aux deux conditions
suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816


PRINTED IN U.S.A. REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640

ELKAY MANUFACTURING Co • 1333 BUTTERFIELD ROAD SUITE 200. DOWNERS GROVE, IL 60515 USA - 630.574.8484 • www.elkay.com

1000004538 (Rev. F - 03/24) Page 12