The document describes the Honeywell BWTM Ultra multi-gas detector. It has enhanced sensor technology for detecting 5 gases, intuitive display, connectivity features, and rugged design for worker safety in hazardous environments.
The document describes the Honeywell BWTM Ultra multi-gas detector. It has enhanced sensor technology for detecting 5 gases, intuitive display, connectivity features, and rugged design for worker safety in hazardous environments.
The document describes the Honeywell BWTM Ultra multi-gas detector. It has enhanced sensor technology for detecting 5 gases, intuitive display, connectivity features, and rugged design for worker safety in hazardous environments.
The document describes the Honeywell BWTM Ultra multi-gas detector. It has enhanced sensor technology for detecting 5 gases, intuitive display, connectivity features, and rugged design for worker safety in hazardous environments.
Multi-Gas Detector. Extra Detection. Ultra Protection. At Honeywell, we always put your safety where it should be – first. With Honeywell BW™ Ultra, our new portable five-gas detector, you will be able to do the same for your workers. Designed specifically for sampling and monitoring confined spaces, before and after entry, Honeywell BW™ Ultra has enhanced sensor technology, visibility on gas readings, comfort, and connectivity. This makes it the most reliable and user-friendly way to prevent a safety incident.
Extra Gas Detection. Extraordinary.
The Honeywell BW™ Ultra complies with all safety regulations in place by detecting your required gases. Furthermore, it goes the extra mile by offering you the option to choose a fifth sensor from a list of gases – for added protection at work.
The Honeywell BW™ Ultra is the first gas detector on the
market to feature the 1‑Series sensor, with fast response, reliable performance and long life, even in extreme working H2S CO O2 conditions. That means high accuracy and lower costs. LEL VOC CO2
SO2 NH3 H2
Cl2 NO2 HCN
NO
F E AT U R E S & B E N E F I T S
Ultra Easy Ultra Connected
• Tamper-proof operation with one button operation • Honeywell Connected Worker compatible • Intuitive LCD icons for quick decision making • Honeywell TouchConnect™ Technology for activating a feature • Easy service and maintenance • Honeywell SafetySuite for unit configuration and reporting Ultra Visibility Ultra Comfortable • Intuitive large dot matrix display giving clear readings • Ergonomically designed for easy use • Smart Gas layout for clear sensor reading • Light yet rugged design • Hole Watch Mode for quick decision making • Fits in the hand for easy sampling • IntelliFlash™ and also Reverse IntelliFlash™ for clear compliance Ultra Quick Ultra Rugged • Quick responding sensor technology • Honeycomb-designed housing for extra ruggedness • Quick decision making because large display • Protection designed in the right place • Quick bump & calibration with IntelliDoX system • Scratch-resistant display protector Honeywell BW™ Ultra Technical Specifications TECHNICAL SPECIFICATIONS SENSOR SPECIFICATIONS SIZE 5.8 x 3.3 x 1.6 in. / 14.8 x 8.5 x 4.0 cm STANDARD MEASURING WEIGHT 14.5 oz. / 411 g (with clip) GASES RANGE RESOLUTION OPERATING TEMPERATURE -4 to +131° F / -20 to +50° C OXYGEN (O2) 0-25% vol. 0.1% vol. HUMIDITY 5 - 95% RH (non‑condensing) continuous COMBUSTIBLE GASES (LEL) 0-100% LEL 1% LEL INGRESS PROTECTION IP66/68 COMBUSTIBLE GASES (IR)* 0-5.00% vol. 0.01% vol. ALARMS AND TYPE Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit) HYDROGEN SULFIDE (H2S) 0-100 ppm 1 ppm / 0.1 ppm SELF-TEST Activated detectors automatically perform one internal diagnostic CARBON MONOXIDE (CO) 0-2,000 ppm 1 ppm test every 24 hours (sensors, battery, and circuitry). CARBON MONOXIDE (LOW H2) 0-1,000 ppm 1 ppm TYPICAL BATTERY LIFE 18 hours (14 hours with PID or IR sensor) @ -4° F / -20° C (CO-H) PUMP DRAW Sample from up to 75 ft. / 22.9 m SULFUR DIOXIDE (SO2) 0-100 ppm 0.1 ppm CONNECTED WORKER • Bluetooth™ Low Energy (BLE) – Ability to connect HYDROGEN (H2) 0-2,000 ppm 5 ppm to Honeywell’s Safety Communicator App • Honeywell TouchConnect™ – Easy ability to enter CARBON DIOXIDE (CO2) 0-50,000 ppm 100 ppm Bump or Calibration mode or change Set-Points AMMONIA (NH3) 0-100 ppm 1 ppm EVENT LOGGING 30 alarm events and 10 bump events VOLATILE ORGANIC 0-1,000 ppm 1 ppm DATA LOGGING 45 days based on 8 hour shifts every 15 seconds logging COMPOUNDS (VOC) ** USER OPTIONS • Adjust STEL period (5-15 minutes in 1 minute intervals) CHLORINE (CL2) 0-20 ppm 0.1 ppm • Calibration span levels NITROGEN DIOXIDE (NO2) 0-50 ppm 0.1 ppm • Calibration interval • Bump test interval HYDROGEN CYANIDE (HCN) 0-100 ppm 0.1 ppm • Select combustible gases measurement: 0-100% LEL NITROGEN MONOXIDE (NO) 0-200 ppm 1 ppm (Lower Explosive Limit) or Methane gas 0-5.0% v/v • LEL and PID correction factors * Caution – the LEL IR combustible gas sensor option used in • Calibration due date (1 to 365 days, or set to zero for off) Honeywell BW™ Ultra cannot detect certain combustible gases • Individual sensor enable/disable including hydrogen and acetylene. The application should • Latching alarms be reviewed to ensure the Honeywell BW™ Ultra can provide • Stealth mode adequate detection. For more information, please contact • Languages: English, French, German, Portuguese, Honeywell Analytics (www.honeywellanalytics.com). Spanish, Simplified Chinese and Russian ** Please contact Honeywell Analytics for availability. CERTIFICATIONS AND h: Class I, Div 1, Group A, B, C, D APPROVALS Class I, Zone 0, Group IIC ATEX : II 1G Ex ia IIC T4 Ga INTELLIDOX IECEx : Ex ia IIC T4 Ga DOCKING SYSTEM X: European Conformity For additional certifications, please review the manual or consult IntelliDoX combines Honeywell Analytics. smart-docking WARRANTY Instrument: 3 years modules with Sensors: 3 years (2 years NH3, 1 year PID and Cl2) Battery: 2 years our instrument management DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. system to provide automated testing and record keeping.