Trane ®: Intellipak

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

RELEASED 17/Jun/2019 13:50:07 GMT

400D (V) 4 1XP18 400C (V)


121
1XJ18 4

401D (V) 3 1XP18 401C (V)


122
OPTIONAL REHEAT 1XJ18 3
402A (G)
4 400B (V) 2 1XP18 400A (V), 400C (V)
123 M 27VAC
1XJ18 2

1TA2-XP2 -3
1TA2-XP2 -2
1TA2-XP2 -1
2QM5 COM TO
1 1XP18 LINE 51
401B (V) 401A (V), 401C (V)
124 27VAC
1XJ18 1
GREEN/YELLOW
125 1TA2-XP5 J5 J2

GND 3
27 VAC (B) 2
27 VAC (A) 1
R TO
4 1 +24 VDC 1TA1-XP2
1
BK LINE 182
126 M 4 4 2 GND
2
BL
2QM7 3 COMM +
3
GY
127 4 COMM -
4
1TA2-XP4 J4
R 1TA2
128 1 +24 VDC POWER SUPPLY
1
2P1 BK (CONDENSER)
4 4 2 GND
USER 2
BL
129 INTERFACE 3 COMM +
3
GY
4 COMM -
4
130 1TA2-XP3 J3 1TA2-XP11 J11 J1 1TA2-XP1
R
1 +24 VDC 1 +24 VDC 1
1 1 1
BK
131 2 GND 2 GND 2
1XP35 -3 1XJ35 -3 1XP74 -1 1XJ74 -1 2 2 2
TO 427C (BK) 427B (BK) 427A (BK) BL 423A (BK) TO
RETURN CONTROLS 3 COMM + 3 COMM + 3
6TA4-J5 1XP35 -4 1XJ35 -4 1XP74 -2 1XJ74 -2 3 3 3 1TA1-XP5
PANEL COMM 428C (W) 428B (W) 428A (W) GY 424A (W)
132 LINE 302 4 COMM - 4 COMM - 4 LINE 186
4 4 4

4
133

134

135 406A (BL)

238B (BK) 5 1XJ48 238A (BK)


136
1XP48 5
1K1 5
241B (BK) 6 1XJ48 241A (BK) 1XD10 -1 1XD10 -2 1KF11-XP5
137 24VDC 3
Y Y-OUT 1XP48 6 241 239 3
J2
7S9 1KF11-XP2 J1
238A (BK)
138 1 EXT AUTO STOP 2
J11
1

3 7S8 239A (BK) 1KF11-XP2 4


139 2 GND (N) 1
2
J5
9 8 1XD18 -1 1KF11-XP2
406A (BL) 1XD11 -2 1XD11 -1 235A (BK)
140 + 3 EMERGENCY STOP
CUSTOMER 406 240 235 3
24VDC 6
CONNECTION 1XD19 -1 1KF11-XP2
237B (BL) 1XD11 -3 237A (BK)
141 - 4 GND (N)
237 237 4
8
J3
142 1 OCC/UNOCC
1KF11
OCCUPIED/ ZONE SENSE
UNOCCUPIED
143 2 GND (N)

144 3 SPACE 3 SPACE CO2


8 CO2 0-10 VDC
3 J2
J1
145 VOM MODE A 2
J11
N/C 4 GND (N/)
VOM J4 J15
MODE A 4
146 GND (N) 1 1 SPARE 1
J5 SPARE
I/O
147 VOM MODE B 2 GND (N) 2
VOM
MODE B
148 GND (N) 3 SPARE 3
J3 SPARE
I/O
149 1 VOM MODE C 4 GND (N) 4
1KF12
VOM VENTILATION OVERRIDE 3
MODE C
150 2 GND (N)

151 3 VOM MODE D


VOM
MODE D
152 4 GND (N)
J4 J15
153 1 VOM MODE E 1 3
VOM 3
J2
MODE E J1
154 2 GND (N) 2 1 COOL SP 2
J11
COOLING
SETPOINT 4
155 3 SPARE 3 2 GND (N) 1
SPARE J5
I/O
156 4 GND (N) 4 3 HEAT SP
HEAT
SETPOINT
157 4 GND (N)
J3
158 1 ZONE TEMP
1KF10
1KF13 ZONE ZONE CONTROLS
VAV BOX / ALARM OUTPUT TEMP
159 2 GND (N)
3 J2 J1
J11
160 1 3 MODE INPUT

4 MODE
VAV INPUT
161 VAV BOX 2 4 GND (N)
BOX
RELAY
J4 J15
162 3 7 1 CHANGEOVER 1
VAV
CHANGEOVER
163 4 2 GND (N) 2

ALARM ALARM SPACE


164 5 9 3 SPACE HUMIDITY 3
OUTPUT OUTPUT HUMIDITY 4-20 mA

165 6 N/C 4 GND (N) 4

166 7

VOM OUTPUT VOM


167 8
RELAY OUTPUT

168 9

LOCATION CODE LEGEND


169 10
LOC # ZONE DEVICE LINE
DESCRIPTION
1 CONTROL PANEL DESIGNATION NUMBER
SPARE SPARE 1K1 PHASE MONITOR 137
170 11 2 CONDENSER ZONE
RELAY 3 HEAT/EXT CASING 1KF10 LLID (HEX I/O) - ZONE SENSE 154
4 SUPPLY FAN ZONE 1KF11 LLID (HEX I/O) - ZONE CONTROLS 138
171 12
5 EVAP/FILTERS 1KF12 LLID (HEX I/O) - VENTILATION OVERRIDE 145
6 RETURN AIR ZONE 1KF13 LLID (QUAD) - VAV BOX / ALARM OUTPUT 160
172 7 CUSTOMER PROVIDED 1TA2 POWER SUPPLY - CUSTOMER 126
1XD10 TERMINAL BLOCK - EXT AUTO STOP 137
NOTES:
WIRE COLOR ABBREVIATION CODES 1XD11 TERMINAL BLOCK - EMERGENCY STOP 140,141
173
1. UNLESS OTHERWISE NOTED, ALL SWITCHES ARE SHOWN AT 25 C (77 F), AT ATMOSPHERIC PRESSURE, AT 50% RELATIVE HUMIDITY, CODE COLOR CODE COLOR 1XD18 TERMINAL BLOCK - 24VDC CUST CONN 140
WITH ALL UTILITIES TURNED OFF, AND AFTER A NORMAL SHUTDOWN HAS OCCURRED. BK BLACK PK PINK 1XD19 TERMINAL BLOCK - 24VDC COM CUST CONN 141
174 2. DASHED LINES INDICATE RECOMMENDED FIELD WIRING BY OTHERS. DASHED LINE ENCLOSURES AND/OR DASHED DEVICE OUTLINES BL BLUE R RED 2P1 USER INTERFACE 129
INDICATE COMPONENTS PROVIDED BY THE FIELD. PHANTOM LINE ENCLOSURES INDICATE ALTERNATE CIRCUITRY OR AVAILABLE SALES BR BROWN TQ TURQUOISE 2QM5 VALVE - REHEAT 123
OPTIONS. SOLID LINE INDICATES WIRING BY TRANE CO. G GREEN V VIOLET 2QM7 VALVE - COOLING 126
175
3 USE COPPER CONDUCTORS ONLY. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO GY GREY W WHITE 7S8 EMERGENCY STOP 139
SO MAY CAUSE DAMAGE TO THE EQUIPMENT. O ORANGE Y YELLOW 7S9 EXTERNAL AUTO STOP 138
176
4 GROUND LOW VOLTAGE PANEL TO MAIN CONTROL BOX.
DESIGNER: K. EDWARDS
INTELLIPAK
177
5 REMOVE JUMPER AND INSTALL EXTERNAL AUTO/STOP WHEN REQUIRED. ENGINEER: S. MCKINLEY
TRANE ®
6 FOR EMERGENCY STOP, REMOVE JUMPER BETWEEN 1XD11-1 AND 1XD11-2 AND INSTALL FIELD PROVIDED DEVICE. TRANE © DATE: 05/14/2019 DIAGRAM
REPLACES: 12132586-C THIS DRAWING IS PROPRIETARY
178 7 CUSTOMER SUPPLIED VAV CHANGEOVER RELAY/CONTACTS REQUIRED ON MODULATING GAS HEAT UNITS FOR OPERATION OF
AND SHALL NOT BE COPIED CONTROLS SCHEMATIC - 20T-75T
OCCUPIED VAV HEAT MODE.
SIMILAR TO: -- OR ITS CONTENTS DISCLOSED FIELD WIRING AND
FOR SPACE CO2 OPERATION, CONNECT FIELD INSTALLED SENSOR TO 1KF11-J3, 1XD18 AND 1XD19 AS SHOWN. TO OUTSIDE PARTIES WITHOUT
179 8
REVISION DATE: -- THE WRITTEN CONSENT OF TRANE. CONDENSER CONTROLS
9 FOR SPACE HUMIDITY OPERATION, CONNECT FIELD INSTALLED SENSOR (+) TO 1XD18 AND (-) TO 1KF10-J4 AS SHOWN. REVISED BY: -- MASTER NUMBER: DRAWING NUMBER: SHEET: REV
180 APPROVED BY: --
CAD SYSTEM USED: PRO/ DIAGRAM IEC DESIGN COMPLIANT
12133319 3 OF 7 A