NOTES / LEGEND

3 4 GENERAL
602-10 602-10 4 1. THIS SET OF DRAWINGS IS TO BE READ IN CONJUNCTION WITH THE RELEVANT
210-05 DRAWINGS FROM OTHER DISCIPLINES AND ANY IS CREPANCIES BETWEEN THEM
SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY.

70000 2. NO SCALING OF DIMENSIONS IS PERMITTED ON THESE DRAWINGS. ONLY


WRITTEN DIMENSIONS WHICH, UNLESS OTHERWISE STATED(u.n.o), ARE GIVEN IN
5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 MILLIMETERS, MAY BE DEEMED TO BE CORRECT. IF ANY DIMENSION SEEMS
BASIC WALL TYPES DOUBTFUL, THE ENGINEER SHALL BE CONSULTED.

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 3. ALL EXISTING DIMENSIONS AND LEVELS ARE TO BE CHECKED ON SITE AND


CORRELATED WITH THE ARCHITECT'S DRAWINGS BY THE CONTRACTOR. ANY
75mm DRY WALL DISCREPANCIES OR VARIATIONS FROM THE DRAWINGS SHALL BE REPORTED TO
THE ENGINEER IMMEDIATELY. NO WORK SHALL COMMENCE NOR ANY MATERIAL
3 BE ORDERED UNTIL THE ENGINEER IS NOTIFIED ACCORDINGLY.
P P
201-06
100mm ROCKWOOL INSULATED PANEL 2HR

550
550
4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ALL MATERIAL

972
FIRE RATED SHALL COMPLY AND ALL WORKMANSHIP SHALL BE EXECUTED IN STRICT
CHILLER CHILLER ACCORDANCE WITH THE DETAILS AND SPECIFICATIONS SHOWN ON THESE
P.P
BASIC WALL : 230 mm P&P UP P.P DRAWINGS, THE LATEST REVISIONS OF SANS 10400, SANS 1200, THE NATIONAL

600
SB SB VITAGRID VE 40 40x4.5 DITCH COVER
D01 D02 100mm INSULATED PANEL BUILDING REGULATIONS (NBR) AND THE LATEST EDITIONS OF THE RELEVANT

BASIC WALL : 230 mm P&P

BASIC WALL : 230 mm P&P

1:80
570 22480 SANS CODES OF PRACTICE AND STANDARDS METHODS, IRRESPECTIVE
WHETHER THE ENGINEER HAS INSPECTED THE WORKS ON SITE OR NOT.

308
BASIC WALL : 115 mm P&P WHERE A SANS CODE HAS BEEN REPLACED BY A SANS CODE IT IS DEEMED

1:80

3850
1:80
3850 D12 THAT THE LATEST VERSION OF THE RELEVANT CODE IS APPLICABLE.
MAIN ELECTRICAL LCV 6
EPOXY PAINT 5. ALL WATERPROOFING DETAILS TO BE IN CONJUNCTION WITH THE ARCHITECT'S

GENERATOR PLINTH

GENERATOR PLINTH

GENERATOR PLINTH
35 m²
PACKING MATERIALS 1:49 602-10
SPECIFICATIONS AND INSTRUCTIONS, U.N.O.

1:80
EPOXY PAINT PLANT ROOM
EPOXY PAINT 280 mm CAVITY WALL

8000
145 m² 280 mm 2hr FIRE WALL
8000

4500
145 m²
1:44 1:48 6. ALL BRICKWORK SETTING OUT TO BE DONE ACCORDING TO THE ARCHITECT'S
P.Q 1:48 1:45 P.Q DRAWINGS
1:36 7. ALL CONCRETE SETTING OUT TO BE DONE ACCORDING TO THE ENGINEER'S
5
280 mm 2hr FIRE WALL
1:47 1:37 BASIC WALL : 230 mm P&P
DRAWINGS

602-10 8. 100mm CONCRETE FLOOR TO BE LAID UNDERNEATH THE 150mm CONCRETE

1:47

3600
TRANSFORMERS MV DB
3600

D12 FLOOR FOR THE INSULATED PANELS TO BE FIXED ON

1:63
GRANO GRANO

1:48
27 m² 6 m²

1620
1:63
D01 D02 4850 2000 1100 2000 1100 2000 1950 280 mm 2hr FIRE WALL

Q Q

D02 D02 D02


D14 D13 D13

G-FL PLANT ROOM LAYOUT COLUMN CROSS - SECTION TYPE


SCALE 1 : 100 260

70000
5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000

COL #1
STORAGE 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

400
COLUMNS
11.200

COOLING TOWER

COOLING TOWER

COOLING TOWER

COOLING TOWER
MAIN COLUMNS
6.800

TOC 4945 TOC 4945

TOC 4250 TOC 4250

BEAM_260 x 680mm BEAM_260 x 680mm BEAM_260 x 680mm BEAM_260 x 680mm BEAM_260 x 680mm BEAM_260 x 680mm BEAM_260 x 680mm BEAM_260 x 680mm BEAM_260 x 680mm BEAM_260 x 680mm BEAM_260 x 680mm

TOC 3570 D02 TOC 3570 TOC 3570


TRANSFORMERS MV DB
GRANO GRANO
BASIC WALL : 230 mm P&P

BASIC WALL : 230 mm P&P


PACKING MATERIALS D01 27 m² 6 m²

280 mm 2hr FIRE WALL

280 mm 2hr FIRE WALL


EPOXY PAINT COL PLANT ROOM COL COL COL PLANT ROOM COL COL
145 m² #1 EPOXY PAINT #1 #1 #1 EPOXY PAINT #1 #1
COL COL COL 145 m² 145 m²
#1 #1 #1
D12
FLOOR LEVEL
0.000

Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6)
COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm

PLANT ROOM - SECTION 5


5 602-10
SCALE 1 : 100
PROJECT STATUS

5000 5000 5000 5000 5000


50000

5000 5000 5000 5000 5000


CONSTRUCTION
APPROVED BY COUNCIL / CLIENT
17 18 19 20 21 22 23 24 25 26 27

Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m)
COL_M2 - IPE400 - COL_400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm
CITY ENGINEER / CLIENT REG. NO. DATE
IPE400 AMENDMENTS CODE

P A,B,C.../ : BEFORE TENDER /A : BY CLIENT


550

T0 / : TENDER DRAWING /B : BY ARCHITECT


COL COL COL COL COL COL COL COL COL COL COL
#1 #1 #1 #1 #1 #1 #1 #1 #1 #1 #1 0,1,2..../ : AFTER TENDER /C : BY MECHANICAL OR ELECTRICAL
P.P /D : BY BVi
Z / : AS BUILT
/E : BY OTHER ( )
DATE INITIAL No./CODE REVISION DESCRIPTION
3850

09 Feb 2024 MvN 0 CONSTRUCTION


26 MAR 2024 MvN 1 PLANT ROOM EQUIPMENT ADDED
Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6) Base S1 (1.8x1.8x0.6)
COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm COL_S1 - 400mm x 260mm
COL COL COL COL COL COL COL COL COL COL COL
8000

#1 #1 #1 #1 #1 #1 #1 #1 #1 #1 #1
P.Q

COPYRIGHT VESTS IN THIS DOCUMENT AND NO USE OR REPRODUCTION OR DUPLICATION


3600

THEREOF MAY OCCUR WITHOUT THE WRITTEN CONSENT OF BVI CONSULTING ENGINEERS
Base S2 (1.8x1.4x0.6) Base S2 (1.8x1.4x0.6) Base S2 (1.8x1.4x0.6) Base S2 (1.8x1.4x0.6) Base S2 (1.8x1.4x0.6) Base S2 (1.8x1.4x0.6) Base S2 (1.8x1.4x0.6) Base S2 (1.8x1.4x0.6) Base S2 (1.8x1.4x0.6) Base S2 (1.8x1.4x0.6) Base S2 (1.8x1.4x0.6)
OFFICES
COL_S2 - 400mm x 260mm COL_S2 - 400mm x 260mm COL_S2 - 400mm x 260mm COL_S2 - 400mm x 260mm COL_S2 - 400mm x 260mm COL_S2 - 400mm x 260mm COL_S2 - 400mm x 260mm COL_S2 - 400mm x 260mm COL_S2 - 400mm x 260mm COL_S2 - 400mm x 260mm COL_S2 - 400mm x 260mm
COL COL COL COL COL COL COL COL COL COL COL 8000 PROVINCE OFFICE  E-MAIL
#1 #1 #1 #1 #1 #1 #1 #1 #1 #1 #1 Gauteng Tshwane (012) 940-1111 pta@bvigp.co.za
Q 550 3850 3600 Polokwane (015) 291-5400 plk@bvilp.co.za
Free State Bloemfontein (051) 447-2137 bfn@bvifs.co.za
Welkom (057) 353-2499 wel@bvifs.co.za
P P.P P.Q Q Northern Cape Upington (054) 337-6600 upt@bvinc.co.za
Springbok (027) 712-9990 spk@bvinc.co.za
KwaZulu Natal Durban (031) 266-8382 dbn@bvikn.co.za
Empangeni (035) 772-6112 emp@bvikn.co.za
Eastern Cape Port Elizabeth (041) 373-4343 plz@bviec.co.za
East London (043) 726-1444 plz@bviec.co.za

FOUNDATION LAYOUT - PLANT ROOM Western Cape Cape Town (021) 527-7000
Visit or contact us online at www.bvigroup.co.za
cpt@bviwc.co.za

SCALE 1 : 100

8000 VITAGRID VE 40 40x4.5 DITCH COVER


150mm THC. CONCRETE
550 3850 3600 FLOOR LEVEL SLAB
0.000 COOLING TOWER

P P.P P.Q Q
400
550

150mm THC. CONCRETE Registration no. 1998/000157/07


SLAB FOR TRENCH FLOOR
CLIENT
150

100 115 600 115 100 STEEL PLATFORM FOR


COOLING TOWERS - SEE
1030
DETAILS ELSEWHERE

IPE400 TOC 4945

CABLE TRENCH SECTION 6

695
TOC 4250 TOC 4250
250mm THK ROOF SLAB 250mm THK ROOF SLAB

SCALE 1 : 20 602-10 BOC 4000


BEAM_260 x 680mm BEAM_260 x 680mm BEAM_260 x 680mm
PROJECT
BOC 3570
BEAM_260 x 680mm BEAM_260 x 680mm
IPE400 BEAM_260 x 680mm BEAM_260 x 680mm

PLANT ROOM
DOOR SCHEDULE - PLANT ROOM AREA EPOXY PAINT
145 m² BELCO NEW REGWA PACKHOUSE
Mark BVi_Type Door Name Type Count
COL COL
PACKING MATERIALS D01 PLANT ROOM DOUBLE EMERGENCY EXIT DOOR 1800 x 2100 mm (1950 x 2175 mm) 2 #1 #1
EPOXY PAINT
145 m² D02 DRAWING TITLE
COL COL COL
D02 PLANT ROOM ROLLER SHUTTER DOOR 2400 X 3000 5
#1 #1 #1 D12 PLANT ROOM TRANSFORMER DOOR 1800x2100mm 2
D13 PLANT ROOM TRANSFORMER DOOR 2500x3000mm 2
D14 PLANT ROOM SONGLE HOLLOW STEEL DOOR 1000x2100mm 1

FLOOR LEVEL
0.000
FLOOR LEVEL
0.000
PLANT ROOM

APPROVED BY BVi

Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base S1 (1.8x1.8x0.6) Base S2 (1.8x1.4x0.6) Base (2.6x1.8x0.6m) Stub (0.7x0.45x1.0m) Base S1 (1.8x1.8x0.6) Base S2 (1.8x1.4x0.6)
COL_M2 - IPE400 - COL_400mm x 260mm COL_S1 - 400mm x 260mm COL_S2 - 400mm x 260mm COL_M2 - IPE400 - COL_400mm x 260mm COL_S1 - 400mm x 260mm COL_S2 - 400mm x 260mm M. van Niekerk 20150073 FEB 2015
ENGINEER/TECHNOLOGIST REG. NO. DATE

PLANT ROOM - SECTION 3 PLANT ROOM - SECTION 4 SCALE As indicated @ A0 DRAWN T. M. CLOETE
3 602-10 4 602-10
DESIGNED T. M. CLOETE CHECKED M van Niekerk
SCALE 1 : 50 SCALE 1 : 50 PLAN NUMBER REVISION NO. DATE SAVED

33585.01S-602-10 1 26 MAR 2024

0 10 50 100 C:\Users\theo.cloete\Documents\33585.01-ARCH-BELCO REGWA PACKHOUSE - ver 23_Theoc_BVi.rvt