Frs 2021
Frs 2021
Frs 2021
: FRS2021100
Service Manual
Side By Side Refrigerator
Model: FRS-2021
FRS-2041
FRS-2421
FRS-2441
! Notice !
There was an engineering change in Side By Side Refrigerators.
The function that controls Top Hinge's left and right side was removed.
As a result, "Installation Guide" was modified and "Screw Machine" was deleted in service manual.
This change took effect on Nov. 11th, 2003.
So please refer to the revision service manual for the SBS models produced after Nov. 11th, 2003
.
✔ Caution
: In this Manual, some parts can be changed for improving, their
performance without notice in the parts list. So, if you need the
latest parts information,please refer to PPL(Parts Price List) in
Service Information Center (http://svc.dwe.co.kr).
2. SPECIFICATIONS ---------------------------------------- 9
2-1. OUTLINE ---------------------------------------- 9
2-2. ELECTRIC PARTS ---------------------------------------- 10
2-3. POWER CORD ---------------------------------------- 13
2-4. DOOR COLOR ---------------------------------------- 14
FRS-2021
816
25.5
925 127 12.5 676.5
651
20
391
524
61 66
50
30
1707
1650
1808
82.5
108
47.5
3.5
-3-
816
25.5
925 127 12.5 676.5
651
20
391
524
61 66
50
30
1707
1650
1808
82.5
108
47.5
3.5
-4-
896
25.5
925 127 12.5 756.5
731
20
391
524
61 66
50
30
1707
1650
1808
82.5
108
47.5
3.5
-5-
896
25.5
925 127 12.5 756.5
731
20
391
524
61 66
50
30
1707
1650
1808
82.5
108
47.5
3.5
-6-
FRS-2021 / FRS-2421
1 9
2 10
11
3 12
13
14
15
5 16
6 17
7 18
19
8 20
-7-
1 9
2 10
11
3 12
13
14
15
5
16
6
17
7 18
19
20
8 21
-8-
2-1. OUTLINE
DIVISION CONTENTS
-9-
2) RELAY
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220 / 60 220~240 / 50 230 / 50
3) STARTING CAPACITOR
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220 / 60 220~240 / 50 230 / 50
4) RUNNING CAPACITOR
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220 / 60 220~240 / 50 230 / 50
- 10 -
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
6) R-FAN MOTOR
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
7) C- FAN MOTOR
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
8) DEFROST HEATER
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
9) DRAIN HEATER
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
- 11 -
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
- 12 -
5 3011300801 BP-3PIN
※ Upper power cord's part code is only lead wire, without any kinds of terminal or houisng
- 13 -
- 14 -
Display
INPUT Control Object
Front PCB buttons
FRZ SET. button / REF SET. button
LCD
SUPER FRZ. button / SUPER REF. button
LOCK button / SLEEP button
CONTENTS REMARKS
1. Normal Operation
1) Temperature control of Freezer / Refrigerator
( Initial mode : Freezer & Refrigerator -> Middle )
2) Lock mode : unlock(OFF) / Sleep mode : OFF
3) SPEED icon : inactive
4) FUZZY & DEODORIZER letters and icons : always ON
5) Other display modes
Normal Operation Silent Mode
Sleep
CUSTOM LCD Normal Silence
Load Mode Mode
Mode Mode
Freezer / Refrigerator BAR DIAL DIAL DIAL DIAL DIAL
- 15 -
Temperature progress : Low -> (Low-Mid) -> Mid -> (Mid-High) -> HIgh
Temp. indication : -15C -17C -19C -21C -25C
Number of bars : 5EA 3EA 5EA 3EA 5EA
6. "SLEEP" button
1) Start by pushing the button ("ON" lights.)
2) Stop by pushing button again ("OFF" lights.)
3) Automaticcally terminated after maximum 12 hours ("OFF" lights.)
7. "LOCK" button
1) Start by pushing the button ("LOCK" letters and icon light.)
* No other buttons and modes, buzzer sound are controllable.
2) Stop by pushing button again for a second ("OFF” and icon light.)
- 16 -
CONTENTS REMARKS
4. FC [Low -> (Low-Mid) -> Mid -> (Mid-High)] DIFF : 2 degrees respectively
( * [(Mid-HIgh) -> High] DIFF : 4 degrees )
-11.0C
-13.0C ON point
-15.0C
-20.0C
-21.0C
ON/OFF DIFF
-16.0C
-18.0C
-20.0C OFF poin t
-22.0C
-26.0C
- 17 -
14V
F Fan
12V
90min. 60min.
* STEP DIFF. :
fixed by MICOM
2. R-fan are controlled by ON / OFF point of each mode.
4. RC [Low -> (Low-Mid) -> Mid -> (Mid-High)] DIFF : 1 degree respectively
5. Prevention of weak/poor-refrigeration
1) When weak refrigeration is sensed, comp. is ON regardless of F-sensor.
2) When R-sensor reaches R-fan OFF point, comp. is controlled by F-sensor and
R-fan turns OFF.
3) Sensing point of weak refrigeration : R-sensor OFF point of each mode + 7C
4) Termination point : Same as R-sensor OFF point of each mode
- 18 -
9.3 C
8.3 C
7.3 C Weak refrigeration point
6.3 C
5.3 C (Off point+7C)
2.65 C
1.65 C
0.65 C ON point
-0.35 C ON/OFF
-1.35 C
2.3 C
DIFF
1.3 C
0.3 C OFF point (0.35 deg)
-0.7 C
-1.7 C
- 19 -
5. After Sleep mode stops all the electrical parts return to normal operation and Sleep
icon changes from “ON” to “OFF”.
6. If Sleep mode starts during PRECOOL, it goes on again after the Sleep mode is
terminated.
7. If Sleep mode starts during Super FRZ., Super REF., it returns to previous set
modeafter the Sleep mode is terminated.
- 20 -
2. Condition to start
1) The optical or light sensor in top middle of control panel senses surround light and
Silence mode starts if the amount of light sensed is below the standard value for
more than 1 minute.
(The mode does not start for initial 240 minutes to prevent down of cooling
performance.)
a. Standard value to decide ‘night’: below 5~7 Lux (optical sensor surface)
b. Standard value to decide ‘daytime’: above 4~16 Lux
(optical sensor surface)
3. Control Method
Control Mode F-FAN R-FAN C-FAN
4. Termination Condition
The mode stops if lux value is above the standard for more than 1 minute.
1. CDS SENSOR
2. R SENSOR 1. F-FAN (14V, 12V, 10V)
3. F SENSOR
CONTENTS REMARKS
* Control of Silence mode : operation mode when the optical sensor feels that it is
night
* Normal control : daytime operation mode
(Refrigerator noise is relatively low at daytime.)
* Load control : operation mode when inside temperature goes up due to an
increase of load (foods) or frequent door openings
- 21 -
2) Display : "SPEED" lights until the mode and speed icons flicker.
5) Control Method
5-1) Control mode by F/R-door open time (over 30 seconds)
-> F/R-fan works by 14V respectively.
5-2) Control mode by [F-sensor On Point + 5 degree]
-> F-fan works by 14V.
5-3) Control mode by [R-sensor On Point + 5 degree]
-> R-fan works by 14V.
* C-fan works by 10V as normal.
6) Conditions to stop
a. The mode works for 20 minutes.
(If another condition happens at the end of the mode, it starts again.)
b. When it reaches to [F-sensor Off point], F-fan load control mode stops.
c. When it reaches to [R-sensor Off point], R-fan load control mode stops.
- 22 -
Door
On + 5deg
F/S
14V
F Fan 12V
20min.
On + 5deg
R/S
14V
12V
R Fan 20min.
Ref. Load
Door
On + 5deg
F/S
F Fan 12V
10V
20min.
On + 5deg
R/S
12V
R Fan 8V 20min.
Ref. Load
Frz. Stop Condition ;
Door Open Frz. Load Stop after 20min.
30sec. after open Frz. Load Start
Ref. Load Stop
Load Mode Start Frz. Overload Input
HTR
F/S
Comp
F Fan
12V
Normal Operation
On + 5deg
R /S
2 0 m in.
14V
R Fan 8V
- 23 -
Sart
N 240 minutes ?
Normal Silence
Control Mode
Fan RPM
Fan RPM
Normal Overload
F Fan : 12V
F Fan : 10V 12V
R Fan : 12V
R Fan : 10V 12V
C Fan : 10V
C Fan : 10V 12V
N
Y F/S ON + 5deg?
Freezer
Compartment N
Overload Overload of both
Y R-sensor ON + 5deg? compartments
Refrigerator N
Compartment
Overload
Overload mode ? N
Y
Normal mode
Overload mode control
control
F load control ;
Y
over 20 min. ?
N
End
- 24 -
REMARKS
CONTENTS
- 25 -
Start
Yes
No
No
No
Yes
No
No
No
No
- 26 -
1. Defrosting Mode
1) Time ; 50 minutes
2) Comp. / F-fan : ON
Pre-Cool R-fan : Control
Heater : OFF
3) If F-sensor <
= - 27C, PRE-COOL becomes OFF.
1) If D-sensor >
= 10C, Heater becomes OFF.
2) In case of Heater return by time limit of 40 or 80 min
Heater (F3-Error)
3) Heater is ON for 30 minutes (time limit) in case of D-
Defrosting sensor error.
4) Time limit
a. 30 seconds : Heater is ON regardless of D-sensor
temperature right after defrosting start.
b. 30 minutes : in case of D1-Error
c. 80 minutes : in normal control state
1) Time : 5 minutes
Fan Delay Comp. : ON
F/R-fan, Heater : OFF
2. Initial Defrosting
If D-sensor = < 3.5C, defrosting mode starts from Pre-Cool at initial power input or
first plugin.
- 27 -
CONTENTS REMARKS
1. How to start
1) Set “LOCK ON” first.
2) Push “LOCK” button 3 times while pushing “REF SET.” button at the same time.
2. Display
Error code is displayed on Freezer temperature display part.
3. How to stop
1) Push “LOCK” button 3 times while pushing “REF SET.” button.
2) It stops automatically 4 minutes after the start.
5. Error Code
- 28 -
1) "F1" ERROR
a. Cause : F-sensor disconnection / short (pull-down)
b. Control : Comp. / F-fan -> ON for 25min., OFF for 25min.
c. if F-sensor is normal, the error is terminated automatically.
2) "r1" ERROR
a. Cause : R-sensor disconnection / short (pull-down)
b. Control : Condition of ambient temperature
RT/S In ERROR ~ 13C 14 ~ 19C 20 ~ 29C 29C ~
Work rate 8 / 12 7 / 13 8 / 12 8 / 12 9 / 11
ON/OFF
c. If R-sensor is normal, the error is terminated automatically.
3) "rt" ERROR
a. Cause : RT-sensor disconnection / short (pull-down)
b. Control : Normal operation, deletion of control condition by RT-sensor
c. If RT-sensor is normal, the error is terminated automatically.
4) "d1" ERROR
a. Cause : D-sensor disconnection / short (pull-down)
b. Control : Time limit (30min.) of defrosting-return
c. If D-sensor is normal, the error is terminated automatically.
6) "C1" ERROR
a. Cause : in case comp. works for over 3 hours when D-sensor temp. is over -5C
b. Control : Normal operation
c. When D-sensor temp. is below -5C in comp. OFF, it is terminated.
7) "F3" ERROR
a. Cause : in case defrosting-return is done by time limit of 80min.
b. Control : Deletion of Pre-cool mode in defrosting mode
c. If defrosting-return is done by D-sensor, it is terminated.
- 29 -
2. How to proceed
1) Delete Pre-cool mode. (Others are same as normal defrosting.)
2) Heater is ON regardless of D-sensor temp. at first 30 seconds.
( Check of defrosting current)
D-sensor
Defrosting Mode
Initial or first power input (power plugin)
CONTENTS REMARKS
If D-sensor temp. =
< 3.5C, defrosting mode starts from Pre-cool at first Comp. is delayed for 6 min.
power input. at the initial defrosting.
F-PCB buttons
Door Switch BUZZER
Initial Power Input
CONTENTS REMARKS
- 30 -
1. Start
Push “REF SET.” button for 3 seconds within 10 seconds just after power
input.
2. Control
1) Electrical components are OFF for 3 hours.
2) Display operates in normal way.
- 31 -
1Min 1Min
ON
OFF
R FAN
0.5sec.
ON
F FAN
OFF
1.0sec.
ON
C FAN
OFF
1.5sec.
OPEN
DOOR
CLOSE
ON
R FAN
OFF
20.5 sec. (0.5sec.
for first 2 hrs.)
ON
F FAN
OFF
21sec. (1sec. for first 2 hrs.)
- 32 -
Demonstration Function
INPUT Control Object
“LOCK” button COMP
“REF SET.” button F-FAN
“SLEEP” button R-FAN
CONTENTS REMARKS
1. Start
1) Set “LOCK ON” first.
2) Push “SLEEP” button 5 times while pushing “REF SET.” button simultaneously.
2. Control
1) All other electrical components are OFF except for F-fan / R-fan.
2) Fan Control
DOOR OPEN -> FAN ON / DOOR CLOSE -> FAN OFF
3) Display : Normal mode (3.8sec.) -> SPEED(3sec.) -> Silent mode(3sec.) ->
Sleep mode (3sec.)
3. Stop or Termination
1) During Demo mode push “SLEEP” button 5 times while pushing “REF SET.”
button simultaneously.
2) Power in again.
- 33 -
R-SENSOR
R26
R70
OP1-1
R71
OP1-2
Summary of Function
CONTENTS REMARKS
- 34 -
* DC output
15.7V
11.96V
- 35 -
SMPS *Minimum
IC PIN standard
3,4 voltage at OVP
start :
23.2V
- 36 -
SMPS
IC PIN
3,4
- 37 -
[ D-sensor ]
-> It senses return point of defrosting heater.
Working Point Return point of defrosting heater
Working Temp. 10 C
.
Resistance =. 19.53 k
Sensing Voltage 3.1 V
- 38 -
normal way ;
1) Cut J18 on M-PCB, then temp. is lowered -2 C than [Mid OFF point].
2) In addition to 1) action, cut J22 on M-PCB, then the temp. is lowered –1 C more.
Relay Function
Circuit Diagram
How it works ;
ON Condition OFF Condition
Control Control Method
MICOM Port IC3 Output Pin MICOM Port IC03 Output Pin
. . . .
COMP RELAY # 16 =. 3.7V # 14 =. 0.7V # 16 =. 0V # 14 =. 12V
. . . .
F-LAMP RELAY # 15 =. 3.7V # 13 =. 0.7V # 15 =. 0V # 13 =. 12V
. . . .
HB-HTR RELAY # 14 .=. 3.7V # 12 .=. 0.7V # 14 .=. 0V # 12 .=. 12V
HTR RELAY # 13 =. 3.7V # 11 =. 0.7V # 13 =. 0V # 11 =. 12V
. . . .
R-LAMP RELAY or SSR # 12 =. 3.7V # 10 =. 0.7V # 12 =. 0V # 10 =.12V
- 39 -
How It Works ;
ON Condition OFF Condition
Control Control
MICOM Port MICOM Port
Object Method IC Collector IC Collector
31 32 33 31 32 33
Low (10V)
5V 0V 0V 10.35V 0V
operation
Mid (12V)
F-FAN 0V 5V 0V 12.19V 5V 5V 5V 0V
operation
High (14V)
0V 0V 0V 14.38V 0V
operation
- 40 -
CODE:WSBS1-3
- 41 -
Main PCB
- 42 -
- 43 -
Freezer Refrigerator
Compartment Compartment
- 44 -
Welding Points
5% 7 points
35 % 5 points
- 45 -
1) Exchanging F-lights
* Replacing F-lights.
- Assembling order is the reverse of disassembling.
- 46 -
* Pull forward Ice case and lift up a little to remove then pull Ice cubes maker.
4) Front Cover
- 47 -
- 48 -
* Insert a flat tip driver into the left down groove of panel frame and snap it out smoothly.
* Remove housing from F-PCB and screws on the board to change for a new one.
* Assembling is the reverse order of disassembling.
- 49 -
1) Deodorizer
2) Top R-Light
- 50 -
* Snap out the bottom hook of light cover with a flat tip screw driver.
* Hold down the light cover to pull out.
* Change the light bulb.
(Assembling is the reverse order of disassembling.)
4) Wine Holder
* Remove two screw caps on the top of Wine holder with a (-) driver.
* Unscrew 2 screws with a (+) dirver.
* Hold end of wineholder and pull up smoothly after seperating completely fixed hook.
(Assembling is the reverse order of disassembling.)
5) Shelves
- 51 -
7) Dairy Pocket
- 52 -
- 53 -
!
Turn top hinge fastener counterclockwise
2 3~4 times.
@
@
- 55 -
@
@
- 56 -
!
@ @
!
Turn the hinge fastener tightly to the end.
3 Connect harness wirings and screw ground
wire.
- 57 -
!
Insert the bottom hole of refrigerator door
1 straight to the bottom hinge pin.
@
@
- 58 -
1 Insert a screw driver (flat tip) into a groove of the left wheel (bottom of freezer) and turn it
clockwise until the door is balanced. (clockwise to raise freezer door ; counterclockwise
to lower)
Unless the freezer door is balanced by step 1, then follow the next steps.
2 Open the doors, unscrew the front cover and remove, if it is attached.
3 Loosen 3 hinge bolts(1 on the left + 2 on the right) a little. (Do not unfasten them
completely) Insert a hexagonal wrench into the groove of adjusting nut and turn
clockwise until the door is level.
4 Once the door is balanced, fasten the hinge bolts tightly and screw the front cover.
Hinge Bolt
1 Insert a screw driver (flat tip) into a groove of the right wheel (bottom of refrigerator) and
turn it clockwise until the door is balanced. (clockwise to raise refrigerator door ;
counterclockwise to lower)
Unless the refrigerator door is balanced by step 1, then follow the next steps.
2 Loosen 3 hinge bolts(2 on the left + 1 on the right) a little. (Do not unfasten them completely)
Insert a hexagonal wrench into the groove of adjusting nut and turn clockwise until the
door is level.
Front Cover
After installation and/or door leveling, fasten front cover with screws.(Remove the screws on the front bottom panel first.
Click and screw the cover)
The front of refrigerator needs to be higher just a little than the back for easy door
closing, but if the wheel is raised too much for door balance, i.e. front of refrigerator
is too higher than the back, it can be difficult to open the door.
- 59 -
FRS-2021 / FRS-2421 16
15
CABINET
14
13
7 10
1 12
3
9 11
8
6
4
2
18
20
19
17 24
21
25
26
22 23
27
MECH ROOM 48 49
41 42
40
43
46
47
39 44 45
37 34 35
38
29 31
36 33 32
30
- 60 -
50
R ROOM
51
53
55 52
56 54
57
59 58
63 61 60
64 62
81 80
82
83
67
92
69 68
91
66
70
88
90
71 89
72 84
73
74 85
87 86
75
77 78
79
76
93
- 61 -
F ROOM
112 96
111 110 98
114 109 97
101 99
115 100
106
117 107 105
113
118
119
108
120
67
103
121
102
122
123
124 94
75 104
95
125
- 62 -
F DOOR
136 139
135 138
129 141-6
132
129-2
141-5
129-1
141-4
141-3
141-2
134 141
127
128
127 140
137
147
133
148
134
149
150
151
152
140
137
- 63 -
6
4
2
18
20
19
17 24
21
25
26
22 23
27
MECH ROOM
48 49
41 42
40
43
46
47
39 44 45
37 34 35
38
29 31
36 33 32
30
- 64 -
50
R ROOM
51
53
55 52
56 54
57
59 58
63 61 60
64 62
81 80
82
83
67
92
69 68
91
66
70
88
90
71 89
72 84
73
74 85
87 86
75
77 78
79
76
93
- 65 -
F ROOM
112 96
111 110 98
114 109 97
101 99
115 100
106
117 107 105
113
118
119
108
120
67
103
121
102
122
123
124 94
75 104
95
125
- 66 -
F DOOR
136 139
135 138
129 141-6
132
129-2
141-5
129-1
141-4
141-3
141-2
134 141
127
128
127 140
137
R DOOR 140
139
153
155-2
155 141
154 138
- 67 -
- 68 -
- 69 -
- 70 -
means that you're recommended to refer to the No. 2-2 "Eletric Parts".
- 71 -
✔ Caution: In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the
latest parts information, please refer to PPL(Parts Price List) in Service information Center(http://svc.dwe.co.kr)
NO PART CODE PART NAME PART DESCRIPTION Q'TY REMARK
3000003600 ASSY CAB URT 1 FRS-2041
1
3000025700 ASSY CAB URT FR-S690CG/CR FRS-2441
2 3012917600 HINGE *T *R AS PO T3.0 1
3 3012918500 HINGE *T *L AS PO T3.0 1
4 3012013000 FIXTURE *T HI PP 2
6 3011472400 COVER HI *T *R PP 1
7 3011472300 COVER HI *T *L PP 1
8 7112401211 SCREW TAPPING T1 TRS 4 x 12 MFZN 2
9 3012601301 HANDLE CAB COVR *R PP 1
10 3012601201 HANDLE CAB COVR *L PP 1
11 7112401211 SCREW TAPPING T1 TRS 4 x 12 MFZN 1
12 3010533400 BOX MAIN PCB PP 1
13 CAPACITOR RUN 1
14 PCB MAIN AS 1
15 3011472610 COVER MAIN PCB BOX PP 1
16 7112401211 SCREW TAPPING T1 TRS 4 x 12 MFZN 1
17 3012917810 HINGE *U *R AS PO T5.0+PAINTING 1
18 3012917710 HINGE *U *L AS PO T5.0+PAINTING 1
19 3012513300 GUIDE *U HINGE *U POM 2
20 7002501611 SCREW MACHINE TRS M5 x 16 MFZN 2
21 3016001240 SPECIAL BOLT *T 6 x 22 SWCH22A(YL) 8
22 3015306700 SUPPORTER *U HI AS PO T5.0 2
23 3012104400 FOOT ADJUST AS 2
24 3016501200 CASTER TURN AS TURN CASTER 2
25 3016001240 SPECIAL BOLT *T 6 x 22 SWCH22A(YL) 2
26 3011471010 COVER CAB BRKT PP 1
27 7142401611 SCREW TAPPING T2 TRS 4 x 16 MFZN 3
29 3010326700 BASE COMP AS SBHG T1.2 1
30 3016003300 SPECIAL BOLT T2 M6.5 x 20 4EA 4
31 CORD POWER AS 1
32 7112401211 SCREW TAPPING T1 TRS 4 x 12 MFZN 1
33 7051401065 SCREW MACHINE PAN 4 x 10 SW BSNI 1
34 COMP 1
35 3016002500 SPECIAL WASHER SK-5 T0.8 4
36 3010101440 ABSORBER COMP AS 4
38 RELAY STARTING 1
39 3011113500 CASE VAPORI PP + CTALC 1
40 3013201700 HOSE DRAIN PEHD 1
41 3014413730 PIPE WICON AS 1
42 3010102100 ABSORBER C MOTR NR FRB-5350NT 1
43 3012004400 FIXTURE C MOTR SUS 1
44 3015911500 MOTOR C FAN AS DC12V 2.5W 1
45 3011802200 FAN ABS (O.D.)3.17 x D110 1
- 72 -