AED9101C: User Manual
AED9101C: User Manual
AED9101C: User Manual
AED9101C
Digital Transducer Electronics
Basic Device for AD103C
with RS232, RS422, RS485
I1692-2.0 en
Content 1
Content
Typographical conventions................................................................................................ 3
Index................................................................................................................................... 26
AED9101C en HBM
2
HBM AED9101C en
Typographical conventions 3
Typographical conventions
For clear identification and improved legibility, the following conventions have been used in
this documentation:
CE Designation
“File Open“ All menus and menu commands appear in quotes, here the “File” menu and the “Open”
sub-menu.
“Start” Quotes and italics are used for buttons, input fields and user input.
MSV All commands are set out in a bold font style or as a link to the command description.
AED9101C en HBM
4 Important information
Important information
Neither the design of the device nor any technical safety aspects may be modified without
the express permission of Hottinger Baldwin Messtechnik GmbH. Any modification ex-
cludes Hottinger Baldwin Messtechnik GmbH from any and all liability for any damage re-
sulting therefrom.
It is strictly forbidden to carry out any repairs and soldering work on the motherboards or to
replace any components. Repairs may only be carried out by persons authorized thereto
by Hottinger Baldwin Messtechnik GmbH.
All the factory defaults are stored safe from power failure at the factory, not in the measur-
ing amplifier where they can be deleted or overwritten. They can be reset at any time by
using the command TDD0. For more information, see aed_help_e, AD103C; “Description
of the basic commands”.
HBM AED9101C en
Safety instructions 5
Safety instructions
There are not normally any hazards associated with the product, provided the notes and
instructions for project planning, assembly, appropriate operation and maintenance are
observed.
Each time, before starting up the modules, you must first run a project planning and risk
analysis that takes into account all the safety aspects of automation technology. This
particularly concerns personal and machine protection.
It is essential to comply with the safety and accident prevention regulations applicable to
each individual case.
Installation and start-up must only be carried out by suitably qualified personnel.
During installation and when connecting the cables, take action to prevent electrostatic
discharge as this may damage the electronics.
The required power supply is an extra-low voltage with safe disconnection from the
mains.
When connecting additional devices, comply with the local safety requirements.
All the interconnecting cables must be shielded cables. The screen must be connected
extensively to ground on both sides.
The power supply and digital I/O connection cables only need to be shielded if the ca-
bles are longer than 30 m (32.81 yd) or are routed outside closed buildings
(EN 61326-1).
The CE mark enables the manufacturer to guarantee that the product complies with the
requirements of the relevant EC directives (the declaration of conformity is available at
http://www.hbm.com/HBMdoc).
In accordance with national and local environmental protection and material recovery
and recycling regulations, old devices that can no longer be used must be disposed of
separately and not with normal household garbage.
If you need more information about waste disposal, please contact your local authorities
or the dealer from whom you purchased the product.
AED9101C en HBM
6 Introduction and appropriate use
AED9101C digital transducer electronics are part of the AED component family that digitally
conditions signals from mechanical measurement sensors and networks them with bus ca-
pability. These include digital amplifier motherboards, basic devices with serial interfaces
and intelligent sensors with integrated signal processing. The purpose of these components
is to directly digitize and condition the measurement signals at the transducer location. Using
digital transducer electronics, you can connect SG1) transducers in a full-bridge circuit di-
rectly to a computer or a PC. This enables you to configure complete measurement chains
quickly and with little extra work.
Basic device AED9101C can contain the AD103C amplifier board. It provides mechanical
protection, shields the amplifier board (EMC protection) and allows you to select the serial
interfaces RS422 (factory default), RS485 or RS232.
The AD103C amplifier mother board is not included in the scope of supply of the basic de-
vice and must be ordered separately.
The AD101B amplifier is only required for replacement and will not be considered when new
AED basic devices are ordered.
The PC software AED PANEL 32 is available to facilitate parameter settings, to display dy-
namic measurement signals and for comprehensive analysis of the dynamic system.
The HBM display unit DWS2103 can be connected to all AED basic devices.
All basic devices of the AED family can be connected with the digital display unit DWS2103.
This unit supports all implemented functions of the AED.
The abbreviation AED is also used for transducer electronics in the following text.
1)
Strain Gage
HBM AED9101C en
Mechanical construction 7
2 Mechanical construction
The basic device extends the functionality of the AD amplifier boards and provides:
the power supply for the amplifier motherboard and transducer excitation
EMC-tested
Diagnostic bus
(The AED9101A basic device can be replaced by the AED9101C basic device)
The amplifier motherboard is designed as a plug-in board that can be plugged into the carrier
board of the basic device via a 25-pin D-connector. The basic device contains terminals for
the transducer, power pack and interface connections, slide switches for interface selection
and the voltage stabilizer. The connection cables exit the casing via PG glands on the side.
AED9101C en HBM
8 Electrical connections
3 Electrical connections
A connection diagram is attached inside the lid of the AED9101C basic device.
When making the connections, please ensure that the wires of the cable do not protrude
beyond the connection terminals (risk that loops may form). Please make sure that the
cable shielding is properly connected to the PG gland.
HBM AED9101C en
Transducer connection 9
The 6-wire connection avoids the effect of a long cable on the measured value. When sev-
eral transducers and a junction box are used, the 6-wire circuitry is routed to the junction
box.
Fig. 3.1-2: Transducer connection in the AED9101C basic device for a 6-wire connection
AED9101C en HBM
10 Transducer connection
There are two methods of connection for transducers implemented in four-wire circuitry:
Connection via a 6-core extension cable; bridged sensor circuit in the transducer con-
nector.
Plug-in connection
bu
Transducer
bu gn
rd
Cable to
wh wh
transducer electronics
bk gy
bk
Cable shield
Fig. 3.1-3: Transducer connection in 6-wire circuitry via a 6-core cable extension
HBM AED9101C en
Transducer connection 11
Connection without an extension cable; sensor circuit bridged at the transducer electron-
ics.
Fig. 3.1-4: Transducer connection in 4-wire circuitry without a cable extension (jumpers 2 – 2‘
and 3 – 3‘)
Connection without an extension cable; sensor circuit at transducer electronics. When con-
necting several transducers, it is advisable to use an HBM junction box VKKx. In general, the
feed lines running to the AED should be shielded cables.
When connecting several transducers to the AED, the number of load cells that can be con-
nected (and the resultant bridge resistance) must be taken into consideration with regard to
the external supply voltage, so that the maximum power loss in the basic device is not ex-
ceeded.
AED9101C en HBM
12 Transducer connection
U in (V)
30
24 23 OC [73.4 O
F]
21
16
13 70 OC [158 OF]
Impedance ( )
350 175 87 58 43
1 2 3 4 5 6 7 8 Number of transducers
Fig. 3.1-5: Maximum operating voltage for the AED9101C basic device, with regard to the number of
transducers and the ambient temperature
For load cells with a 6-wire connection, feedback lines 2´ and 3´ are bridged in the load cell
with excitation 2 and 3 (Fig. 3.1-2). For load cells with a 4-wire connection, the feedback
bridges must be implemented directly at the load cell connection (Fig 3.1-3 or 3.1-4).
HBM AED9101C en
Transducer connection 13
4-wire circuit:
As correction through AUTOCAL can only ever take place up to feedback points 2´, 3´, all
the changes of cable resistances affect the measurement result. This means that even if no
further changes are made to the 4-wire cable used for calibration, there will still be meas-
urement errors when there are temperature changes, because the cable resistance and pos-
sibly the contact resistances at the connectors are temperature-dependent. With the 4-wire
circuit, feedback lines 2´ and 3´ are directly connected at connection terminals 2 and 3 in the
AED (see Fig. 3.1-4).
Equivalent circuit of the bridge with bridge resistance RB and supply lines with
line resistances RL1 and RL2:
RB UBR
RL2
= 3,14 I = Length of cable, A = Cross-section of cable
RL1 = RL2 = 1,6 at I = 10 m and A = 0,14 mm2
AED9101C en HBM
14 Transducer connection
The voltage drop over the bridge feeder cables can be determined from bridge resistance
RB, cable length l, cable cross-section A and the bridge excitation voltage:
For
RB = 80 , RL1 = RL2 = 1,6 (l = 10 m) and UBR = 5 V
and thus a voltage drop over the two line resistances totaling approx. 0.2V (UBridge = 4.8 V).
For
RB = 80 , RL1 = RL2 = 16 (l = 100 m) and UBR = 5 V
and thus a voltage drop over the two line resistances totaling approx. 1.4 V
(UBridge = 3.6 V = 80 0.045).
This is irrelevant for the 6-wire circuit, as the voltage drop over the sensor lines is taken into
account in the measurement signal.
But with a 4-wire circuit, the dependency of the copper resistance of the cables on tempera-
ture goes directly into the measurement result, as the bridge excitation voltage UBridge
changes:
where RL20 is the line resistance at 20 °C and is the temperature coefficient of the cop-
per.
With a cable length of l = 100m and a temperature differential of 10 °C, there is a line resis-
tance of
This change in bridge excitation voltage directly at the transducer changes the measurement
signal of the bridge by 1.9 % (= 100 % (1 – 3.53 V / 3.6 V)).
This typical calculation shows that if long cables are involved, only 6-wire circuitry should be
used.
HBM AED9101C en
Connecting the supply voltage 15
The voltage feed must be shielded. It can be applied within the interface cable or be imple-
mented as a separate cable.
When supplying several AEDs via one cable, the voltage drop over the cable must be taken
into consideration. The voltage drop depends on the supply current required and on the line
resistance.
AED9101C en HBM
16 Connection to a computer
HBM AED9101C en
Connection to a computer 17
No bus mode
The RS232 interface allows the AED to be connected directly to a PC. The cable length is
limited to 15 m and bus mode is not possible.
For the RS232 interface setting, the “bus termination switch must be set to OFF”.
The RS422 interface is a 4-wire interface also with a maximum cable length of 1000 m. To
connect the AED to the COM port of a PC (RS232), you need an interface converter. This in-
terface is not designed for bus mode, as the transmitter is always active.
AED9101C en HBM
18 Connection to a computer
Bus mode
The RS485 interface with a 4-wire connection allows the full range of AED functions with a
maximum cable length of 1000 m. To connect the AED to the COM port of a PC (RS232),
you need an interface converter.The RS485 interface with a 2-wire connection also allows
cable lengths of 1000 m. To connect the AED to the COM port of a PC (RS232), you need
an interface converter
(1-SC232/422B from HBM, with 2-wire mode selected). However, the AED must be operated
in half-duplex mode (command COFxxx must be set). The command MSV?0; must not be
used, as it is not possible to interrupt data output with the STP; command.
Basically, shielded cables should be used for the interface wiring, with the cable shielding
being connected to the AED housing via the PG (see AED9101C cable connection via the
PG gland). The power supply can also be connected via this cable, with a 6-core, shielded
cable being necessary.
The shielding of the physical circuit is connected to the AED line (not to the power supply
ground).
UB: 8 V...30 V DC
Interface converter
RS232 - RS485
PC COM port
RxD TxD HBM Wägetechnik GmbH
RS 485-Bus AED 9101C
CONVERTER SC232/422A
TxD RS232
RxD 8...30V
TA TA (blue)
RS485
GND 2/4-wire
GND TB TB (black)
RA RA (green)
SUB-D connector SUB-D female connector
9-pin (PC) 9-pin (converter) RB RB (grey)
PIN PIN
2 = RxD 2 = TxD GND GND (white)
3 = TxD 3 = RxD
5 = GND 5 = GND UB UB (red, 8...30 V DC)
Equivalent
Interface marking:
TA = T- TB = T+
RA = R- RB = R+
Fig. 3.3-3: Connecting an AED (RS422 or RS485 4-wire) to a computer via the interface converter
HBM AED9101C en
Multi-channel measurements (bus mode, RS485) 19
With the RS485 interface, several AEDs can be connected to a common bus line. The bus
cabling for 4-wire mode is shown in Fig. 3.4-1.
With the RS485 interface, up to 32 AEDs can be connected to a common bus line. With the
aid of the RS485 bus driver, it is possible to implement long cables (up to 1000 m
(1,093.61 yd) in length).
AED bus mode is set out as a Master-Slave configuration, with the AED implementing a
slave.
This means that all the AED activities are initiated from the control computer. Each AED is
given a separate communication address (00...89) and can then be activated by an
Sii (ii = 00...89) Select command.
AED9101C en HBM
20 Multi-channel measurements (bus mode, RS485)
The termination resistances of 500 marked in the above diagram are important for the
electrical function of the bus system. These resistances safeguard the quiescent level for the
receiver on the bus line. The physical circuit must only be connected with these resistances
at the line ends.
For the local bus termination distribution shown in the diagram, the Master and the AED with
address 89 should include the termination resistances. Which is why in this AED, the bus
termination is activated using the “bus termination ON” switch. This bus termination in the
AD103C must also be activated using the commands STR1; and TDD1 (see file aed_help_e,
AD103C; “Description of the basic commands”). If the “bus termination switch is set to OFF”,
the command STR will have no effect, which means that bus termination is deactivated.
The HBM interface converter also includes these bus termination resistances (do not deacti-
vate them).
These terminations must not be activated more than twice in one bus.
The ground of the interface driver is related to the GND terminal. The interface driver of
the master should be also connected to this GND.
The quiescent level on the RS485 physical circuit is produced in 4-wire mode at:
As the RS485 is a differential bus interface, the quiescent level is also specified as a differ-
ential voltage between the lines (and not ground-related). Furthermore, please note that this
interface tolerates a maximum common-mode range of ±7 V. If it should be necessary, a
separate cable can be used to establish potential equalization between the bus nodes. The
cable shielding must not be used for this potential equalization.
HBM AED9101C en
Multi-channel measurements (bus mode, RS485) 21
Fig. 3.4-2: Bus structure RS485 2-wire bus (general, TB/RB = T/R+, TA/RA = T/R-)
Termination resistances are also necessary for the electrical function of this bus system.
These resistances safeguard the quiescent level for the receiver on the bus line. These ter-
mination resistances are already included in the AED and should be set with the “bus termi-
nation switch” (see 4-wire circuit). The quiescent level on the RS485 physical circuit is pro-
duced in 2-wire mode at:
AED9101C en HBM
22 Connecting the diagnostic bus
The diagnostic bus is used to analyze dynamic processes. The bus is set out as an RS485
2-wire bus (lines: TB/RB and TA/RA, GND).
The interfaces setting of the bus is defined and cannot be changed (38400 bit/s, 8E1).
External bus termination resistances are not necessary for this bus.
The HBM interface converter (1-SC232/485B) can be used to connect the RS485 bus to an
(RS232) COM port of the PC.
HBM AED9101C en
Connecting the diagnostic bus 23
The ground of the interface driver is related to the GNDext terminal. The interface driver of
the master should be also connected to this GNDext.
Only a connecting cable with a screen grounded on two sides should be used as the inter-
connecting cable between the AED 9101C and the bus and the master (see also:
AED9101C cable connection via a PG gland)
The functions and commands of the diagnostic channel are described in the help file
aed_help_e Diagnosis. The address corresponds to the address of the AD103C amplifier,
command ADR (00...89, factory setting: 31), see aed_help_e, Basic Commands). This ad-
dress is independently from the CANOpen address.
The diagnostic functions can be executed using the HBM AED_Panel32 program (as from
Version V3.0.0).
The HBM display unit DWS2103 can be connected with this interface. Than all implemented
functions and parameters are accessible. This is independent from the main communication
channel.
AED9101C en HBM
24 Trigger input
An external sensor (light barrier, contact, etc.), can be connected to the trigger input of the
AD103C, to drive the trigger measurement function (see file aed_help_e, AD103C; “Descrip-
tion of the signal processing”).
The input is activated as an external trigger by the TRC command.
If the input is not required, the input remains unassigned. The GND of the trigger input is
connected to the GND of the supply voltage.
HBM AED9101C en
AED9101C cable connection via a PG gland 25
Only a connecting cable with a screen grounded on both sides (and metal connectors)
should be used as the connecting cable between the AED9101C and its partner device.
Bring the screen extensively into contact on both sides at the PG gland (and at the metal
shell of the connector). If the partner device does not have a metal connector, connect the
cable shielding extensively to ground. If there are vast differences between the ground po-
tential of the AED9101C and its partner device, a potential equalization line must be pro-
vided in addition.
Fig. 3.7-1: Connecting the transducer, supply voltage and computer to the PG gland
AED9101C en HBM
26 Index
Index
4
4-wire circuitry.................................................................................................................................................10, 11
6
6-wire connection..............................................................................................................................................9, 12
B
basic box ............................................................................................................................................................... 7
bridge excitation voltage .................................................................................................................................12, 14
bridge resistance ......................................................................................................................................12, 13, 14
bus
bus line ............................................................................................................................................................ 19
bus structure ...............................................................................................................................................19, 21
bus mode........................................................................................................................................................16, 19
RS232.............................................................................................................................................................. 17
RS485....................................................................................................................................... 16, 18, 19, 20, 21
bus termination ...............................................................................................................................................20, 21
bus termination RS485 ..................................................................................................................................... 19
C
cable connection.................................................................................................................................................. 17
cable connection - serial interface..................................................................................................................... 16
cable connection supply voltage
cable connection AED9101C .......................................................................................................................15, 25
cable length ....................................................................................................................................................12, 14
computer connection............................................................................................................................................ 16
connection to a computer, AED9101C .............................................................................................................. 16
connecting the diagnostic bus .............................................................................................................................. 22
D
diagnostic bus...................................................................................................................................................... 22
E
electrical connections............................................................................................................................................. 8
I
interface............................................................................................................................................................... 16
interface converter ..........................................................................................................................................16, 18
HBM AED9101C en
Index 27
L
load cell connection ............................................................................................................................................. 12
M
manufacturer’s notes ............................................................................................................................................. 6
mechanical construction......................................................................................................................................... 7
multi-channel measurements ............................................................................................................................... 19
P
PG gland ....................................................................................................................................................8, 16, 25
potential equalization ........................................................................................................................................... 16
Q
quiescent level
RS485.............................................................................................................................................................. 19
R
RS232 ..........................................................................................................................................................6, 7, 16
RS232 serial interface.......................................................................................................................................... 16
RS422 ..........................................................................................................................................................6, 7, 16
RS485 with 2-wire................................................................................................................................................ 16
RS485 with 4-wire................................................................................................................................................ 16
S
serial interface ................................................................................................................................................... 6, 7
RS232............................................................................................................................................................ 6, 7
RS422.......................................................................................................................................................6, 7, 16
RS485.............................................................................................................................................................. 16
supply voltage...................................................................................................................................................... 15
supply voltage AED9101C................................................................................................................................ 25
T
trigger input.......................................................................................................................................................... 24
U
use ........................................................................................................................................................................ 6
AED9101C en HBM
HBM AED9101C en
AED9101C en HBM
Modifications reserved. Hottinger Baldwin Messtechnik GmbH
All details describe our products in general form only.
They are not to be understood as express warranty
and do not constitute any liability whatsoever. Postfach 100151 D-64201 Darmstadt
Im Tiefen See 45 D-64293 Darmstadt
Tel.: +49/6151/803-0 Fax: +49/6151/8039100
I1692-2.0 en E-mail: support@hbm.com · www.hbm.com