Permanent_GFRP

Technical Data Sheet ASTEC Glass Rebar (Permanent)

Bar
Grade: 45P (MoE: 45 GPa) Grade: 50P (MoE: 50 GPa)
Nominal Nominal Linear Material Mechanical Properties Material Mechanical Properties
Dia Dia. CSA Weight Ultimate Ultimate
Ultimate Ultimate Ultimate Ultimate
(mm) (mm2) (kg/m) Tensile Tensile
Fiber Resin Tensile Load Tensile Fiber Resin Tensile Load Tensile
Strength Strength
(kN) Strain (%) (kN) Strain (%)
(MPa) (MPa)
6 6.4 32 0.07 ECR VE 29 910 2.02% ECR + H VE 29 920 1.84%
10* 9.5 71 0.16 ECR VE 59 834 1.85% ECR + H VE 65 910 1.82%
13* 12.7 127 0.24 ECR VE 96 758 1.68% ECR + H VE 114 900 1.80%
16* 15.9 199 0.41 ECR VE 144 725 1.61% ECR + H VE 177 890 1.78%
19* 19.1 284 0.60 ECR VE 195 685 1.52% ECR + H VE 250 880 1.76%
22* 22.2 387 0.77 ECR VE 249 644 1.43% ECR + H VE 333 860 1.72%
25* 25.4 510 0.98 ECR VE 324 635 1.41% ECR + H VE 428 840 1.68%
29 28.7 645 1.30 ECR VE 384 595 1.32% ECR + H VE 529 820 1.64%
32 32.3 819 1.60 ECR VE 450 550 1.22% ECR + H VE 631 770 1.54%
41 41.3 1338 2.61 ECR VE 709 530 1.18% ECR + H VE 990 740 1.48%
51 50.8 2027 4.08 ECR VE 1013 500 1.11% ECR + H VE 1418 700 1.40%
Grade: 60P (MoE: 60 GPa) BEND BAR TYPE 1, MAX = 2.5m x 2.5m*
Nominal Nominal Linear Material Mechanical Properties
Dia Dia. CSA Weight Ultimate
Ultimate Ultimate
(mm) (mm2) (kg/m) Tensile
Fiber Resin Tensile Load Tensile
Strength
(kN) Strain (%)
(MPa)
6 5.86 27 0.07 ECR + H VE 29 1075 1.79% BEND BAR TYPE 2,
9* 8.81 61 0.16 ECR + H VE 65 1067 1.78% MAX = Dia. 1.5m*

12* 11.68 107 0.24 ECR + H VE 114 1063 1.77%


15* 14.63 168 0.41 ECR + H VE 177 1053 1.75%
18* 17.61 244 0.60 ECR + H VE 250 1026 1.71% BEND BAR TYPE S, MAX = 4.5m x 1.5m*
21* 20.54 331 0.77 ECR + H VE 333 1005 1.67%
23* 23.27 429 0.98 ECR + H VE 428 998 1.66%
26 26.48 551 1.30 ECR + H VE 529 961 1.60%
30 29.68 692 1.60 ECR + H VE 631 912 1.52%
38 38.02 1135 2.61 ECR + H VE 990 872 1.45%
46 N/A N/A 4.08 ECR + H VE N/A N/A N/A
* Avaiable bend bar diameters and shapes for general request, special shape & diamater upon customer's request

Version: rev. 0
Date: Jun-19

Page 1 of 1