Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Datasheet BTL035K 212337 en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Magnetostrictive Sensors

BTL5-E17-M0100-P-S32
Order Code: BTL035K

1) not included in scope of delivery, 2) Non-usable area, 3) Nominal length = Measuring length, 10) Null point, 11)
Installation length

Basic features Environmental conditions


Approval/Conformity CE Ambient temperature -40...85 °C
cULus EN 55016-2-3, Radiation Industrial areas
EAC EN 60068-2-27, Continuous shock 100 g, 2 ms
WEEE
EN 60068-2-27, Shock 100 g, 6 ms
Magnets, number (factory setting) 1
EN 60068-2-6, Vibration 12 g, 10…2000 Hz
Magnets, number max. 1
EN 61000-4-2, ESD Severity Level 3
EN 61000-4-3, RFI Severity Level 3
Electrical connection EN 61000-4-4, Burst Severity Level 3

Connection Connector, M16x0.75, 8-pin EN 61000-4-5, Surge Severity Level 2

Connection version axial EN 61000-4-6, High-frequency fields Severity Level 3

Polarity reversal protected Ub up to 28 V EN 61000-4-8 Magnetic fields Severity Level 4


Protection degree IP67 with connector
Relative humidity ≤ 90 %, non-condensing
Electrical data
Storage temperature -40...100 °C
Current consumption max. at 24 V DC 150 mA Temperature coefficient typ. ≤ 35 ppm/K at 50% of nominal
Error signal Ia falling ≤ 3.2 mA stroke 500mm
Error signal Ua falling ≤0V
Error signal Ua rising ≥ 10.2 V
Functional safety
Galvanic isolation yes
MTTF (40 °C) 77 a
Inrush current ≤ 3 A/0.5 ms
Operating voltage Ub 20...28 VDC
Output signal adjustable no Material
Overvoltage protection Ub up to 28 V Cover material Aluminum, Die-cast, nickel plated
Voltage-proof up to (GND to housing) 500 V DC Housing material Aluminum
Housing material, surface protection Anodized

1/2
Internet www.balluff.com eCl@ss 9.1: 27-27-07-03
Subject to change without notice: 212337 ETIM 6.0: EC002544
BTL035K_0.16_2019-10-11
Magnetostrictive Sensors
BTL5-E17-M0100-P-S32
Order Code: BTL035K
Mechanical data Range/Distance
Installation length 246 mm Measuring length 100 mm
Mounting Mounting clamps Non-linearity max. ±100 µm
Null point 73.0 mm Repeat accuracy ≤ ± 0.2 µA
Reproducibility ≤4 µm

Output/Interface Resolution ≤ 0.2 µA


Sampling rate, length-dependent 1 kHz, standard
Analog output Analog, current 20…4 mA

Connector Drawings

Wiring Diagrams

2/2
Internet www.balluff.com eCl@ss 9.1: 27-27-07-03
Subject to change without notice: 212337 ETIM 6.0: EC002544