SERVICE BULLETIN
SUMMARY
AIRBUS INDUSTRIE
CUSTOMER SERVICES DIRECTORATE
1 Rond Point Maurice BELLONTE
31707 BLAGNAC CEDEX FRANCE
Tel: (33) 5 61-93-33-33
Telex: AIRBU 530526 F
REASON/DESCRIPTION/OPERATIONAL CONSEQUENCES
During preparation for flight, sparking and smoke was reported behind the
right hand control panel of the AFT galley. The circuit breakers for the
oven and the boilers were tripped and a reset was not possible. As a
safety measure the AFT galley feeder circuit breakers were pulled.
When the control panel was removed, the electrical connector and
receptacle were burnt and partially melted.
The electrical wiring connecting the control panel to the galley was
found to be too short. This made access to the electrical connector
difficult when removing/installing the control panel.
EFFECTIVITY
None
REFERENCES/REPERCUSSIONS
TFU : None
OEB : None
AOT : None
SIL : None
OTHER : None
AIRCRAFT : YES
EQUIPMENT : NO
HARD : NO
SOFT : NO
OBRM : NO
COMPLIANCE
Recommended
MANPOWER
MATERIAL INFORMATION
AIRCRAFT DATA
None
EQUIPMENT DATA
None
APPENDICES
None
AIRBUS INDUSTRIE
CUSTOMER SERVICES DIRECTORATE
1 Rond Point Maurice BELLONTE
31707 BLAGNAC CEDEX FRANCE
Tel: (33) 5 61-93-33-33
Telex: AIRBU 530526 F
1. PLANNING INFORMATION
A. EFFECTIVITY
(2) Aircraft
AZA001-019 477,488,494,495,434,524
526,532,515,516,513,514
576,583,586,593,599,765
819
RGA001-010 590,594,601,605,607,611
617,619,648,650
(3) Spares
None
B. REASON
(1) History
When the control panel was removed, the electrical connector and
receptacle were burnt and partially melted.
(2) Objective/Action
(3) Advantages
None
C. DESCRIPTION
D. APPROVAL
The technical content of this Service Bulletin has been approved under
the authority of the Direction Generale de L’Aviation Civile FRANCE
(DGAC) Design Organisation Approval No. F.JA.02.
E. MANPOWER
Inspection -
Test 6.25
Close-up 6.00
(1) Material
None
None
I. REFERENCES
J. PUBLICATIONS AFFECTED
None
2. ACCOMPLISHMENT INSTRUCTIONS
A. GENERAL
WARNING : MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND ALL THE
CAUTIONS INCLUDED IN THE REFERENCED PROCEDURES.
(1) Preparation
(c) Remove the contents of the galleys and the galley equipment.
None
None
B. INSPECTION
C. REPAIR
(1) Do any repairs that are necessary in accordance with the AVIO
INTERIORS Service Bulletin 144/685-002 Rev. 01.
D. TEST
(1) Install the FWD galley 2, 6479MM, refer to AMM: 25-31-41, P. Block
401 .
(3) Push the pushbutton switch 2XA GALLEY on the overhead panel 35VU in
the cockpit.
(4) Make sure that the POWER indicator light on the galley electrical
panel comes on.
(5) Make sure that all of the circuit breakers on the galley panel are
closed.
(7) Push the pushbutton switch 2XA GALLEY on the overhead panel 35VU in
the cockpit.
(8) Make sure that the POWER indicator light on the galley electrical
panel goes off.
E. CLOSE-UP
(1) Make sure that the work area is clean and clear of tools and other
items of equipment.
(2) Install the ceiling panels which were removed to get access to the
galley, refer to AMM: 25-23-41, P. Block 401 .
(3) Install the door frame linings which were removed to get access to
the galley, refer to AMM: 25-23-45, P. Block 401 .
F. DOCUMENTATION
Write in the applicable aircraft records that you have done all the work
given in this Service Bulletin.
3. MATERIAL INFORMATION
A. LIST OF COMPONENTS
None
B. SPECIAL TOOLS
None
None
None
AIRBUS INDUSTRIE
CUSTOMER SERVICES DIRECTORATE
1 Rond Point Maurice BELLONTE
31707 BLAGNAC CEDEX FRANCE
Tel: (33) 5 61-93-33-33
Telex: AIRBU 530526 F
...WILL BE EMBODIED
...EFFECTIVITY
FAX : (+33) 5 61 93 28 06