Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Madhepura - Ff-Ele

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

G

H
A

J
I
W W

Riser - 0'-6''
7

7
Tread - 1'-0''
Width - 6'-10'' W
AC POINT AC POINT AC POINT
Computer Computer Computer

(32'-4'' X 59'-3'')
Conference Hall
72 seats capacity

Computer

AC POINT
Computer

Computer

Computer

Computer
AC POINT

Computer
Executive Engineer

Computer

Computer

Computer

Computer
6

6
(13'-3'' X 10'-6'')
D2

Computer

Computer

Computer

Computer

Computer

AC POINT
AC POINT

Work Station Assistant Engineer


(40'-0'' X 21'-2'')
(13'-3'' X 10'-6'')
Civil Division
5

5
Computer Computer

D1 Computer Computer
AC POINT

Lobby
Lobby

AC POINT
(38'-3''
(38'-3''XX15'-6'')
15'-6'')
Work Station
(40'-0'' X 21'-2'')
Transmission

Computer

Computer

Computer

Computer

Computer
Assistant Engineer
Division (13'-3'' X 10'-6'')
4

4
Computer

Computer

Computer

Computer

Computer
AC POINT

AC POINT
Computer

Computer

Computer

Computer

Computer
Executive Engineer
(13'-3'' X 10'-6'')

AC POINT AC POINT AC POINT


Computer
AC POINT

REFERENCE
3

3
QTY. HEIGHT
BATTEN HOLDER POINT 08 NOS. 2400 MM FROM FFL
TUBE LIGHT POINT 04 NOS. 2400 MM FROM FFL
AC POINT

CEILING FAN POINT 42 NOS. CEILING


POWER POINT 31 NOS. 450 MM TO 600 MM FROM FFL
SWITCH BOAR WITH SOKET 18 NOS. 1200 MM FROM FFL
5A SOCKET POINT EXTRA 06 NOS. 450 MM TO 600 MM FROM FFL
5A SOCKET MULTI POINT 17 NOS. 750 MM TO 900 MM FFL
2

2
EXHAUST FAN POINT 04 NOS. 2400 MM FROM FFL
AC POINT AC POINT
Computer Computer
CALL BELL POINT 05 NOS. 2400 MM FROM FFL
IN INTERNET OUTLET 40 NOS. 750 MM TO 900 MM FFL
W TL TELEPHONE JACK 16 NOS. 750 MM TO 900 MM FFL
AC POINT
AC POINT 19 NOS. 900 MM TO 1200MM FROM FFL
4 way
TPN DB
4/6 WAY TPN MCB DB 08 NOS. 1800 MM FROM FFL
1'x1' LED LIGHT POINT 28 NOS. CEILING
2'x2' LED LIGHT POINT 58 NOS. CEILING
LED DOWN LIGHT POINT 12 NOS. CEILING
1

1
Computer COMPUTER POINT 40 NOS. 750 MM TO 900 MM FFL
MIRROR LIGHT POINT 04 NOS. 1300 MM TO 1500MM FROM FFL

FIRST FLOOR PLAN 2X1.5 + 1X1.5 SQ.MM WIRE


2X2.5 + 1X2.5 SQ.MM WIRE
LIGHT/FAN POINT TO SWITCH BOARD

COMPUTER/MULTI POINT TO DB
2X4 + 1X4 SQ.MM WIRE AC/POWER POINT TO DB
T HI S D RA WING IS T HE P ROP ER TY & NOTE :--
NORTH COPYRIGHT OF M/S SPACE ACE & NO 1. DO NOT SCALE THE DRAWING, FOLLOW WRITTEN DIMENSION ONLY. REVISIONS-01 DRAWN BY - PROJECT TITLE SHEET TITLE CLIENT SHEET NO.
2. ALL DIMENSIONS IN FT.
E PART OF THIS DRAWING MAY BE USED
DATE - 22.05.2023 SPACE ACE
OR REPRODUCED IN ANY MANNER,
STORED IN A RETRIEVAL SYSTEM, OR
3. 450-750 WIDE PLINTH PROTECTION TO BE PROVIDED ALL AROUND THE
BUILDING. CONSTRUCTION OF NEW BUILDING FOR BIHAR STATE POWER ARCHITECTS, ENGINEERS & PLANNERS
4. SKIRTING SHALL BE 100MM. HIGH FROM FINISHED FLOOR LEVEL. SCALE -A/3-NTS
FIRST FLOOR
02
TRANSMITTED IN ANY FORM OR BY ANY
N S ME ANS, ELE CTRONIC , MECHA NICAL,
5. TOILET,PANTRY, KITCHEN VERANDAH & BALCONY FLOOR LEVEL SHALL
BE 12 MM. DOWN FROM GENERAL FLOOR LEVEL. DRG. NO. -BP/ELEC/FF/02
TRANSMISSION CIRCLE OFFICE TRANSMISSION COMPANY V - 20A / 5 ,
PHOTOCOPYING, RECORDING OR D.L.F. CITY III,
OTHERWISE, EXCEPT FOR THE
6. CUPBOARDS SHALL HAVE SKIRTING OF 100 MM. HIGH.
7. LOCATION, SIZES & LEVELS OF MANHOLES TO BE CO-ORDINATED WITH CHECKED BY - BUILDING (G+2) AT MADHEPURA, BIHAR PLAN GURGAON, HARYANA - 122002

W
R ELA TE D PR OJEC T, WI TH OUT THE
WRITTEN PERMISSION OF M/S SPACE
EXTERNAL SEWERAGE LAY OUT PLAN GOT APPROVED BY ENGG.
INCHARGE.
LIMITED, PATNA, BIHAR PH - 0124-4106618,FAX: 0124-2365329
E-MAIL : spaceace.india@gmail.com
A C E . 8. ALL MEASUREMENT MUST BE CHECKED AT SITE BY CONTRACTOR.
G
C

H
A

J
I

You might also like