GENERAL NOTES LEGEND, SYMBOLS AND TOILET AND BATH STANDARD

1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE


PROVISIONS OF THE PHILS. PLUMBING CODE. THE NATIONAL PLUMBING CODE AND ABBREVIATIONS FIXTURE HEIGHT
RULES & REGULATIONS OF THE CITY
SHOWER HEAD AND CURTAIN ROD
2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS.
THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN.
WATER DISTRIBUTION SYSTEM
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS. ANY RELOCATIONS REQUIRED CWL COLD WATER LINE
FOR PROPER EXECUTION OF OTHER TRADE SHALL BE WITH PRIOR APPROVAL OF THE SHOWER VALVE & SOAP DISK
ARCHITECT/ENGINEER. HWL HOT WATER LINE
CWR COLD WATER RISER
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION. DEPTH

1.80
AND INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE HB HOSE BIBB LAVATORY & WATER CLOSET TOP LINE
CONTRACTOR.
GV GATE VALVE

1.20
5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% AND 2% UNLESS WM WATER METER TOILET PAPER HOLDER & FAUCET LINE
OTHERWISE SPECIFIED.

0.90
CV CHECK VALVE

0.60
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
FIN. FLR. LINE
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, COORDINATION
THE WORKS WITH SEWER LINE EFFLUENT DISPOSAL POINT & WATER LINE SERVICE
CONNECTING POINT UNLESS OTHERWISE SPECIFIED. WASTE, SEWER & VENT SYSTEM
8. ALL PIPE SIZES ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METERS UNLESS PLUMBING FIXTURES AND
OTHERWISE SPECIFIED. VTR VENT THRU ROOF
SP SOIL PIPE
CONNECTION PIPE SCHEDULE
9. ALL PIPE DIAMETER ARE INSIDE DIMENSION (NOMINAL) UNLESS OTHERWISE SPECIFIED.
DP DRAINAGE PIPE
MINIMUM PIPE CONNECTION
10. VERIFY ARCHITECTURAL PLANS FOR THE EXACT LOCATION OR SETTING OUT OF FLOOR VP/VPAC VENT PIPE/ VENT PIPE AT CEILING
DRAINS, FLOOR CLEAN-OUTS AND OTHER PLUMBING APPURTENANCES. FCO FLOOR CLEANOUT SYMBOL FIXTURE WASTE/SOIL VENT PIPE WATER PIPE REMARKS
(mm) (mm) (in)
CCO CEILING CLEANOUT
11. ALL CONCEALED VALVES OR VALVES AT CEILING LEVEL SHALL BE PROVIDED WITH ACCESS
VS VENT STACK WC WATER CLOSET 100Ø 50Ø 1/2"Ø FLUSH TANK
MANHOLE.
SS SOIL STACK LAV LAVATORY
12. ALL PIPES PASSING THROUGH WALLS, SLABS AND BEAMS MUST HAVE A PIPE SLEEVE 50Ø 50Ø 1/2"Ø
ONE SIZE BIGGER THAN THE ACTUAL PIPE SIZE TO PREVENT PIPE BREAKAGE AND TO DS DOWNSPOUT
MAINTAIN SLOPE OF THE PIPE. FD FLOOR DRAIN UR URINAL 50Ø 50Ø 1/2"Ø FLUSH TANK

13. RISERS AND STACKS SHALL BE PROVIDED WITH SWAY BRACES EVERY OTHER FLOOR DD DECK DRAIN KS KITCHEN SINK 50Ø 50Ø 1/2"Ø
STARTING AT GROUND FLOOR.
RD ROOF DRAIN BT BATH TUB 50Ø 50Ø 1/2"Ø

BA
RC
AIZ
TD TRENCH DRAIN

TE
GU
SHO SHOWER HEAD --- --- 1/2"Ø

IS
TR
BAHAY

EE
UGNAYAN

T
AD/CB AREA DRAIN/CATCH BASIN
SD SHOWER DRAIN 50Ø 50Ø ---
PARKING GATE 2
AREA

PARKING
GUARDHOUSE
FA FROM ABOVE
AREA
FD FLOOR DRAIN 50Ø 50Ø ---
TB TO BELOW
E
YCL
BIC K
RAC
TA TO ABOVE
GATE 1
T
STREE FB FROM BELOW
REL
. LAU
EP
JOS AC ABOVE CEILING
MATERIAL SPECIFICATION

COLD WATER LINES TAPPING CONNECTION USED GALVANIZE IRON (G.I.) PIPE SCHED. 40, LOCAL
CONFORMING TO ASTM A-53. SUPREME,APO., OR APPROVED EQUAL.

ALTERNATE MATERIAL FOR ROUGHING-IN OF TOILETS AND LATERAL WATER


DISTRIBUTION LINES SHALL BE HIGH DENSITY PPRC - (POLYPROPYLENE
RANDOM COPOLYMER) CLASS PN-20 POLYPROPYLENE TYPE MATERIALS.
FITTINGS SHALL BE FUSION WELD TYPE, IMPORTED CONFORMING TO GERMAN
TECHNOLOGY DIN 8077-8078 AND ASTM 1281-93 SIMILAR TO "PLASTHERM,
PILSA" BRAND OR APPROVED EQUAL.

SEWER LINE SHALL BE POLYVINYL (PVC) PIPE, SERIES 1000 II , "NELTEX" "ATLANTA",
"MOLDEX" BRAND OR APPROVED EQUAL. FITTINGS SHALL BE PVC WITH
SOLVENT CEMENT JOINT TO ASTM D2564.

DOWNSPOUT & SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 1000 II, "NELTEX",
PERIMETER/UNDER DRAIN
"ATLANTA,"MOLDEX" BRAND OR APPROVED EQUAL. FITTINGS SHALL BE PVC
PIPE
WITH SOLVENT CEMENT JOINT TO ASTM D2564.
CONCURRED BY:
VENT LINE SHALL BE POLYVINYL (PVC) PIPE, SERIES 600, "NELTEX", "ATLANTA

ENGR. BENEFREDO O. BULATAO


1 SITE DEVELOPMENT PLAN ,"MOLDEX" BRAND OR APPROVED EQUAL. FITTINGS SHALL BE PVC WITH
DIRECTOR IV P 1 SCALE NTS SOLVENT CEMENT JOINT TO ASTM D2564.
MALACAÑANG ENGINEERING OFFICE

PROJECT NAME AND LOCATION: SHEET CONTENTS: DRAFTED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.

REPUBLIC OF THE PHILIPPINES PLUMBING NOTES CARLA A. PALCONIT


DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS ENGINEER II
PLUMBING LEGEND,SYMBOLS
NATIONAL CAPITAL REGION
RENOVATION OF 5TH ILAC BARRACKS, NEB
AND ABBREVIATIONS PREPARED: P
AREA, MALACAÑANG COMPOUND, J. P. LAUREL
2ND STREET, PORT AREA MANILA ST., SAN MIGUEL MANILA MATERIAL SPECIFICATION ACE JOHN G. REYES SATURNINO E. DIAMZON III HANZEL B. SAMSON JUBY B. CORDON, CEO LORETA M. MALALUAN, CESO IV 1 7
SITE DEVELOPMENT PLAN ENGINEER II ENGINEER III OIC, PLANNING & DESIGN DIVISION ASSISTANT REGIONAL DIRECTOR REGIONAL DIRECTOR
DATE: DATE: DATE: DATE: DATE: