Legend, Symbols and Abbreviations General Notes: Site Development Plan
Legend, Symbols and Abbreviations General Notes: Site Development Plan
Legend, Symbols and Abbreviations General Notes: Site Development Plan
1.80
AND INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE HB HOSE BIBB LAVATORY & WATER CLOSET TOP LINE
CONTRACTOR.
GV GATE VALVE
1.20
5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% AND 2% UNLESS WM WATER METER TOILET PAPER HOLDER & FAUCET LINE
OTHERWISE SPECIFIED.
0.90
CV CHECK VALVE
0.60
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
FIN. FLR. LINE
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, COORDINATION
THE WORKS WITH SEWER LINE EFFLUENT DISPOSAL POINT & WATER LINE SERVICE
CONNECTING POINT UNLESS OTHERWISE SPECIFIED. WASTE, SEWER & VENT SYSTEM
8. ALL PIPE SIZES ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METERS UNLESS PLUMBING FIXTURES AND
OTHERWISE SPECIFIED. VTR VENT THRU ROOF
SP SOIL PIPE
CONNECTION PIPE SCHEDULE
9. ALL PIPE DIAMETER ARE INSIDE DIMENSION (NOMINAL) UNLESS OTHERWISE SPECIFIED.
DP DRAINAGE PIPE
MINIMUM PIPE CONNECTION
10. VERIFY ARCHITECTURAL PLANS FOR THE EXACT LOCATION OR SETTING OUT OF FLOOR VP/VPAC VENT PIPE/ VENT PIPE AT CEILING
DRAINS, FLOOR CLEAN-OUTS AND OTHER PLUMBING APPURTENANCES. FCO FLOOR CLEANOUT SYMBOL FIXTURE WASTE/SOIL VENT PIPE WATER PIPE REMARKS
(mm) (mm) (in)
CCO CEILING CLEANOUT
11. ALL CONCEALED VALVES OR VALVES AT CEILING LEVEL SHALL BE PROVIDED WITH ACCESS
VS VENT STACK WC WATER CLOSET 100Ø 50Ø 1/2"Ø FLUSH TANK
MANHOLE.
SS SOIL STACK LAV LAVATORY
12. ALL PIPES PASSING THROUGH WALLS, SLABS AND BEAMS MUST HAVE A PIPE SLEEVE 50Ø 50Ø 1/2"Ø
ONE SIZE BIGGER THAN THE ACTUAL PIPE SIZE TO PREVENT PIPE BREAKAGE AND TO DS DOWNSPOUT
MAINTAIN SLOPE OF THE PIPE. FD FLOOR DRAIN UR URINAL 50Ø 50Ø 1/2"Ø FLUSH TANK
13. RISERS AND STACKS SHALL BE PROVIDED WITH SWAY BRACES EVERY OTHER FLOOR DD DECK DRAIN KS KITCHEN SINK 50Ø 50Ø 1/2"Ø
STARTING AT GROUND FLOOR.
RD ROOF DRAIN BT BATH TUB 50Ø 50Ø 1/2"Ø
BA
RC
AIZ
TD TRENCH DRAIN
TE
GU
SHO SHOWER HEAD --- --- 1/2"Ø
IS
TR
BAHAY
EE
UGNAYAN
T
AD/CB AREA DRAIN/CATCH BASIN
SD SHOWER DRAIN 50Ø 50Ø ---
PARKING GATE 2
AREA
PARKING
GUARDHOUSE
FA FROM ABOVE
AREA
FD FLOOR DRAIN 50Ø 50Ø ---
TB TO BELOW
E
YCL
BIC K
RAC
TA TO ABOVE
GATE 1
T
STREE FB FROM BELOW
REL
. LAU
EP
JOS AC ABOVE CEILING
MATERIAL SPECIFICATION
COLD WATER LINES TAPPING CONNECTION USED GALVANIZE IRON (G.I.) PIPE SCHED. 40, LOCAL
CONFORMING TO ASTM A-53. SUPREME,APO., OR APPROVED EQUAL.
SEWER LINE SHALL BE POLYVINYL (PVC) PIPE, SERIES 1000 II , "NELTEX" "ATLANTA",
"MOLDEX" BRAND OR APPROVED EQUAL. FITTINGS SHALL BE PVC WITH
SOLVENT CEMENT JOINT TO ASTM D2564.
DOWNSPOUT & SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 1000 II, "NELTEX",
PERIMETER/UNDER DRAIN
"ATLANTA,"MOLDEX" BRAND OR APPROVED EQUAL. FITTINGS SHALL BE PVC
PIPE
WITH SOLVENT CEMENT JOINT TO ASTM D2564.
CONCURRED BY:
VENT LINE SHALL BE POLYVINYL (PVC) PIPE, SERIES 600, "NELTEX", "ATLANTA
PROJECT NAME AND LOCATION: SHEET CONTENTS: DRAFTED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.