1-Hexene Operator Shelter and Satellite Workshop Future Area
1-Hexene Operator Shelter and Satellite Workshop Future Area
1-Hexene Operator Shelter and Satellite Workshop Future Area
GENERAL NOTES
P4 FUTURE INSTALLATION
B) DIAMETERS SHOWN FOR L0TU16 REFERS TO HDPE NOMINAL SIZE PIPE.
16"-65-FW-26841-A2AU16-V
4"-65-FW-26360-A2AU16-B
HOSE REEL FOR 1-HEXENE
65-PP-152-260007
1-HEXENE OPERATOR SIZE EQUIVALENCE TABLE
SATELLITE WORKSHOP
6"-65-FW-26405-A2AU16-B
1002
SHELTER AND
4300-SZ-DM-650260009-01
1 1
1002
SATELLITE WORKSHOP HDPE NOMINAL SIZE HDPE NOMINAL OD HDPE NOMINAL ID EQUIVALENT CARBON
(INCH) (MM) (MM) STEEL NOMINAL SIZE (INCH)
1002
FIRE WATER
500 mm-65-FW-26255-L0TU16-N
65-PP-152-260009-01
125-SF-0001 2 63 49 2
16"-65-FW-26840-A2AU16-V
6"-65-FW-26362-A2AU16-B
24348
FUTURE P4
P4 FUTURE INSTALLATION 125-SG-0020 125-SG-0019 180 mm-65-FW-26404-L0TU16-N 6"-65-FW-26403-A2AU16-B
125 mm-65-FW-26359-L0TU16-N
4 125 97 4
HD
1002 125-SG-0021 Q
16"-65-FW-26386-A2AU16-V
Q Q 1001 1002 6 180 140 6
6"-65-FW-26326-A2AU16-B
6"-65-FW-26325-A2AU16-B
630 mm-65-FW-26340-L0TU16-N
1001
Q Q
180 mm-65-FW-26406-L0TU16-N
FUTURE P4
125-SF-0002
1002
65-SP-26XXX
180 mm-65-FW-26328-L0TU16-N
180 mm-65-FW-26327-L0TU16-N
8 225 175 -
20"-65-FW-26330-A2AU16-V
630 mm-65-FW-26329-L0TU16-N
180 mm-65-FW-26361-L0TU16-N
HD
1001
1002
CONTRACTOR :
P4
10
20"-65-FW-26788-A2AU16-V
250 194 8
20"-65-FW-26445-A2AU16-V
1002
1002
HD HD
BOROUGE :
HD 12
1001
V 3/4" 3/4" 315 245 10
1001
1002
1001
1001
P4
1001
1001
V 250 mmx180 mm 14 355 276 12
65-SV-2656
1002
1002
16"-65-FW-26321-A2AU16-V 65-SV-2657 630 mmx250 mm 16 400 311 -
630 mmx500 mm
630 mmx500 mm
1002 Q
630 mmx500 mm
18 450 350 14
630 mmx500 mm
Q
65-SV-2655
500 mm-65-FW-26340-L0TU16-N
20 500 389 16
500 mmx400 mm
1001 500 mmx400 mm
FIREWATER Q 22 560 422 18
630 mm-65-FW-28258-L0TU16-N 20"
24048 65-PP-152-280009-04 FIRE WATER 24 630 490 20
630 mm-65-FW-28819-L0TU16-N
180 mm-65-FW-26701-L0TU16-N
630 mm-65-FW-26333-L0TU16-N
630 mmx500 mm
20"
630 mmx500 mm
FROM B4 UTILITIES 1001 Q 65-SV-2654 65-PP-152-260001-02 19716 28 710 535 24
SHEET 4 OF 4 18"-65-FW-26715-A2AU16-B 1001 500 mm-65-FW-26329-L0TU16-N 630 mm-65-FW-26442-L0TU16-N 20" 1001
6"-65-FW-26331-A2AU16-B
630 mm
Q Q FROM B4 POLYOLEFINS
TIE IN POINT 65-SV-2653 Q 32 800 603 28
2
IP-C-U4-P4-L-027 1002 THERMAL OXIDIZER PACKAGE 1-HEXENE 1002 1001 1001
AREA SHEET 2 OF 3 2
STORAGE
6"-65-FW-26702-A2AU16-B
1001
FIRE WATER 20"x18" 630 mmx500 mm Q
HD
1002
Q Q 1. HYDRANTS WILL BE EQUIPPED WITH 2 X 2 ½" VALVE HOSE CONNECTIONS WITH INSTANTANEOUS COUPLINGS
180 mm-65-FW-26332-L0TU16-N FOR 1-HEXENE UNIT HD 16" 65-SV-2663
Q 16"-65-FW-26388-A2AU16-V AND 2 X 4" VALVED PUMPER CONNECTIONS.
1001
TEAL & CATALYST 180 mm-65-FW-26389-L0TU16-N
Q 2. MONITORS SHALL BE INSTALLED AT LEAST 15M FROM THE AREA TO BE COVERED.
INJECTION 1002
HD
125-SG-0018 125-SG-0023 1001
Q 500 mmx400 mm 3. ALL UNDERGROUND GATE VALVES SHALL BE CAR SEALED IN OPEN POSITION. ALL UNDERGROUND GATE
PACKAGE Q
VALVES AND ASSOCIATED TRANSITION PIECE JOINTS SHALL BE INSTALLED INSIDE PIT. ALL GATE VALVES
500 mmx400 mm
6"-65-FW-26363-A2AU16-B
HD
Q 6"-65-FW-26337-A2AU16-B SHALL BE PROVIDED WITH EXTENDED SPINDLE AND POST INDICATOR.
HD
1002 1002 125-SG-0017 125-SG-0022 4. THE A2AU16-B PIPES WILL BE COATED IN SITE WITH POLYURETHANE, ACCORDING TO
6"-65-FW-26367-A2AU16-B 6"-65-FW-26390-A2AU16-B 500 mm-65-FW-26400-L0TU16-N ``COATING FOR UNDERGROUND STEEL PIPE BGS-MY-001''.
180 mm-65-FW-26365-L0TU16-N
HD
5. RISERS ON TRANSITION FROM UNDERGROUND PIPING TO ABOVE GROUND PIPING SHALL BE EQUIPPED WITH
1001 16" 1002 1002 1001 PROTECTION AGAINST PHYSICAL DAMAGE
Q 65-SV-2662
125-SG-0002 180 mm-65-FW-26364-L0TU16-N 6. TYPICAL HYDRANT WITH MONITOR CONNECTION. BUTTERFLY VALVE TO BE PROVIDED ON THE 6" STANDPIPE
16"-65-FW-26323-A2AU16-V IS IN VENDOR SCOPE
180 mm-65-FW-26338-L0TU16-N
1001 1-HEXENE UNIT
1002 500 mmx400 mm
1001
500 mm-65-FW-26368-L0TU16-N
1001
3 500 mm-65-FW-26340-L0TU16-N HD 3
Q V
4"-65-FW-26395-A2AU16-B
(INSULATION KIT TYP)
UG AG
Q 6"-65-FW-26339-A2AU16-B C
1002
1002 Q 6"
FIRE WATER 4"-65-FW-26408-A2AU16-B
HD
HD
THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION OF ABU DHABI POLYMERS COMPANY LIMITED (BOROUGE) OR ANY OF ITS LICENSORS.
125-SG-0003 FOR 1-HEXENE PIPE RACK 7. TYPICAL HYDRANT CONNECTION. BUTTERFLY VALVE TO BE PROVIDED ON THE 6" STANDPIPE
125 mm-65-FW-26396-L0TU16-N FIRE WATER
180 mm-65-FW-26714-L0TU16-N 125 mm-65-FW-26410-L0TU16-N
125-SG-0016 Q 26734 65-PP-152-260011
1001 1001 HD
6"-65-FW-26440-A2AU16-B 1001 HOSE REEL FOR MAIN
PIPE PACK BETWEEN 6"
6"-65-FW-26343-A2AU16-B 1002 POLYOLEFINS AREA AND
Q
HD
125-SG-0024 DERIVATIVES AREA
1002
180 mm-65-FW-26441-L0TU16-N Q V
6"-65-FW-26397-A2AU16-B
HD
UG AG
125-SG-0004 C
180 mm-65-FW-26399-L0TU16-N 6"
4 180 mm-65-FW-26344-L0TU16-N 4
500 mm-65-FW-26443-L0TU16-N 1001
EXCEPT PURSUANT TO A WRITTEN AGREEMENT WITH ABU DHABI POLYMERS COMPANY LIMITED (BOROUGE).
1001
8. DELETED. A2AU16-B L0TU16
1001 Q
4"-65-FW-26381-A2AU16-B
180 mm-65-FW-26378-L0TU16-N
FOR 1-HEXENE PIPE RACK
HD
500 mmx400 mm 6"-65-FW-26379-A2AU16-B 125-SG-0025
1001
16"-65-FW-26352-A2AU16-V
1002
1002 6"-65-FW-26401-A2AU16-B
16"
1002 65-SV-2658 Q
FIRE WATER
1002
HOSE REEL
HD
Q
125-SG-0014 180 mm-65-FW-26402-L0TU16-N REFERENCE :
24350
500 mmx400 mm
6"-65-FW-26358-A2AU16-B
355 mm-65-FW-26700-L0TU16-N
18"-65-FW-26392-A2AU16-B
1002
1002
20"-65-FW-26598-A2AU16-V
66-PP-152-260087
66-PP-152-260088
125-SG-0006 125-SG-0007
MANUAL MANIFOLD FOR
125-SG-0015
630 mm-65-FW-26391-L0TU16-N
125 mm-65-FW-26380-L0TU16-N
16"-65-FW-26600-A2AU16-N
UNLOADING AREA
630 mmx500 mm
1002
1001
16"-65-FW-26407-A2AU16-V 630 mm-65-FW-26025-L0TU16-N
630 mmx500 mm
Q 16" 65-SV-2664 Q FIREWATER SYSTEM UNDERGROUND SYSTEM DERIVATIVE AREA SHEET 2 OF 2
Q 65-SV-2661 16"
1002
65-SV-2665
180 mm-65-FW-26377-L0TU16-N 1002 1001
FIRE WATER
FIRE WATER
1002
26751
HD 500 mmx400 mm
1001
180 mm-65-FW-26357-L0TU16-N
500 mmx400 mm
1001
6"-65-FW-26346-A2AU16-B HD FIRE WATER 125-PH-169-00001-01 : FIRE PROTECTION GENERAL LAYOUT 1-HEXENE UNIT SHEET 1 OF 2
5 5
1002 Q 500 mm-65-FW-26353-L0TU16-N 65-PP-152-260001-04 23505
1001
20"
1001 FROM B4 POLYOLEFIN AREA 125-0-65-01 Fire Water Underground for 1-Hexene (Process Area)
HD
SHEET 1 OF 3
1001
Q 20"x18"
630 mm-65-FW-26413-L0TU16-N
125-SG-0005 500 mm-65-FW-26785-L0TU16-N 131-0-65-01 Fire Water Underground for 1-Hexene & PO Common
630 mmx500 mm
630 mmx500 mm
630 mmx500 mm
630 mmx500 mm
1001
630 mmx500 mm
630 mmx500 mm VALVE
20"
PIT
20" 630 mmx500 mm
630 mm-65-FW-26349-L0TU16-N
630 mm-65-FW-26269-L0TU16-N
630 mm-65-FW-26354-L0TU16-N
65-SV-2666
Q 65-SV-2659 A.Waykole C.Balsano/S.Naik/
R.Soldinger
20"-65-FW-26781-A2AU16-V
180 mm-65-FW-26698-L0TU16-N
Checked Approved
1002
1001
Prepared
1001
1001
630 mmx500 mm Q By By By
FIRE WATER 1001
ABU DHABI POLYMERS COMPANY LIMITED
630 mmx500 mm
SHEET 2 OF 2
FIRE WATER
FIRE WATER
SHEET 2 OF 2
SHEET 2 OF 2
TO HEXENE-1 UNIT
TO HEXENE-1 UNIT
65-PP-152-260009-02 26839
6 4700000900 6
Q 20"-65-FW-26708-A2AU16-V CONTRACTOR PROJECT NO
1001 (PROCESS UNIT) (U&O INTERCONNECTING) PO UNIT - RUWAIS, UAE
4300 - PO
1002 630 mmx500 mm
500 mm-65-FW-26413-L0TU16-N PROCESS INTERFACE POINT INTERFACE VALVE LEAD CONTRACTOR DRAWING TITLE: PIPING AND INSTRUMENTATION DIAGRAM
UNIT NUMBER NUMBER LINE NUMBER UNIT 65
1001 FIRE WATER NETWORK 1-HEXENE PLANT SHEET 1 OF 2
FIRE WATER
630 mm U4 IP-C-U4-P4-L-025 ---- 500MM-65-FW-25256-LOTU16-N
65-PP-152-260009-02 19402 BOROUGE DOCUMENT CLASS' N PROJECT DRAWING NO REV: Q
U4 IP-C-U4-P4-L-065 ---- 500MM-65-FW-25257-LOTU16-N
TO 1-HEXENE UNIT 630 mmx500 mm CONTRACTOR: 4300-SZ-DM-650260009-01 SHEET UNIT: 65
SHEET 2 OF 2 1 BOROUGE: 65-PP-152-260009-01 OF AREA: 26
CADD SHEET
A B C D E F REF. 65-PP-152-260009-01-ISQ SCALE: SIZE A1