System with KM20B, KM20BT keypads

Intruder alarm system Short programming manual - basic information

SAFETY WARNINGS
Short programming manual is recommended for the professional installers who are experienced in the installation
of intruder alarm systems and have already read the SecoLink wiring manual. The wiring manual must be read
before the installation to avoid accidents with high voltage and temperature.
The system must be connected to an AC power supply with Protective Earth ground: Phase or Live line (L) - black or
brown cable, Neutral line (N) - blue cable, Protective Earth line (PE) - green cable with yellow along stroke. Double isolated
cables with minimum cross-sectional area of 0,75 mm2 for 230V power supply must be used.
Additional automatic two-pole circuit breaker should be installed in AC electric power circuit in order to prevent over-
current and short circuits. The circuit breaker should be placed close to the system's housing and should be easily reached.
Full power-off could be done by turning off 230V AC main with automatic two-pole circuit breaker and by disconnecting the
battery. Before performing any work of installation or maintenance ALWAYS disconnect device from the power supply.

SYSTEM STARTUP - “FIRST START”


The keypad that comes with the SecoLink security system has been pre-installed with the most frequently used system
settings (further template).
Before installing the system it is possible to connect the keypad with a computer via
MASC
Computer USB and read the template with the help of the software MASCAD (which is free of
charge). Later it is possible to modify the template according to premise's
characteristics and to write it into the keypad again.
USB socket USB
When the wiring works are done and when the system is powered up, words “First
(MINI B) Start” will appear on the keypad. It will mean that the system is ready to automatically
USB cable transfer the data from the keypad to the other modules of the system. “First Start”
procedure also checks what modules are present, the modules are given addresses (ie,
Fig. 1 USB connection
they are registered).
A registered module slowly flash it's address on the system with the help of a green LED, which is located on the module's
PCB (for EXM800, EXT116, EXT216, GSV2A, GSV2C, GSV2M, LAN800, PWR15, RCM800, RCM800WL, for PROX8,
RID820 - via external LED). If the LED is flashing with a poor contrast it means the CLK or DAT line has a wiring problem.
On the keypad LCD :
First Start Entering Service Registering... From KM20 to CP Leaving Service
Press [ENT] Processing...
Press ENT
key. Entering Service. Registration of modules Template is being Leaving Service.
is in progress. sent to the system.

STARTING THE SYSTEM WITH FEW KEYPADS


Sometimes during the first start the words "No control, address 00" may appear on the screens of keypads. It means that
the keypad has the same address in the system as the other keypads or modules. Select the keypad which has a template
prepared by you or select any keypad if all keypads have the same template. Press . This way you will show, which
keypad must start the registration procedure and provide the system with a template. When the is pressed the keypad
will ask system to be a control keypad, it will emit a short audible signal when the control is received and it will show “First
start, Press “ENT”. If the control keypad contains a modified template (project) with all keypads having a precise serial
number and address, just press ENT . If the control keypad contains just a template or the keypad's serial number and
address are not determined in the project, use 1 , 2 , 3 , 4 , 5 keys to manually enter the addresses in the system for
abc def
!
ghi jkl

each keypad. When all keypads addresses are set, press ENT on the control keypad and wait a few minutes for the end of the
registration and the project sending procedure. No Control No Control
For a small system, with a few keypads, it is recommended Address 00 Address 03
to choose keypads addresses in 1 - 4 range, and for the big
The keypad has no control. Address 03 will be
system (PAS832) in 1 - 4 and 10 - 15 range. The idea is not to
Use 1 , 2 , 3 , 4 , 5
abc def
!

assigned to the keypad


ghi jkl

disturb the default addresses of other modules with the


keys to enter address after “First Start”.
addresses of the keypads.
for each keypad.

DEFAULT ADDRESSES OF THE MODULES


The system manufacturer has provided the modules with default addresses assigned to them. This is done in order to
simplify the process of registration for the most frequently used combinations of system modules (such as PAS808, KM20B,
RCM800, GSV2Ñ or PAS816, KM20B, EXM800, RCM800wl, GSV2C). While registering modules of a different type, you will
not need to enter serial numbers of each module, as the system will automatically assign default addresses for the modules
that are listed below:
For all control panels - address 00;
For the keypad KM20B, KM24 - address 01 or 03;
For the keypad with a temperature sensor KM20BT, KM20GT, KM24A - address 02 or 04;
For extra power supply module PWR15 - address 04 or none;
For the zone/PGM expansion module EXM800 - address 05;
For the remote control module EXT116, EXT216, RCM800, RCM800wl, - address 06;
For the user identification module RID820 and proximity reader PROX8 - address 06;
For the GSM/GPRS, LAN communicator GSV2A, GSV2C, GSV2M, LAN800 - address 07.
Page 1
System with KM20B, KM20BT keypads
Intruder alarm system Short programming manual - basic information

CHANGING THE SETTINGS. SERVICE MODE


For the installations with few partitions and more than 10 zones it is recommended to use
the PC and MASCAD software. For small installations it is quite efficient to change the
template manually by using LCD keypad. Changes are made in service mode when the system
is disarmed.
For the security reasons permission to access the service mode has to be given by the user
by entering user's PIN.
There is an option to set the system without the requirement to enter user's PIN for the
service mode access. To do this, you will need to modify the template (before installation) by
using MASCAD software. “User PIN required” check box must be cleared in F - key sheet
(see Fig. 2). Fig. 2 MASCAD software,
There are 2 ways to enter the service mode: F - key sheet
by F - key:
F - key F33 Enable Service: Service Mode: Service Mode:
SERVICE mode User PIN:**** ServicePIN:**** System Setup
by navigating menu:
Main Menu: Enable Service: Service Mode: Service Mode:
Service Mode User PIN:**** ServicePIN:**** System Setup
To start system setup use default PIN code of the first user - 0001, and default service PIN - 0000.

STARTING A SYSTEM WITH 2 EXM800 MODULES


Control panels PAS808 and PAS816 support up to 7 modules on the system and the PAS832
supports up to 15 modules. If there are few modules in the system (two EXM800 or GSV2Ñ and LAN800
for example) with the same default address, these modules will not be registered during the first start
registration procedure. Green LED on module's PCB will make frequent flashes for 0.5 sec. and pause
for 2 sec. (indicating of no address).
In order to register the module an installer must enter service mode, type in 10 digit serial number,
which is on the module’s label, (see Fig. 3) then press ENT key to jump to second row, enter module Fig. 3 EXM800 label
address on the system and to press ENT again to start registration. Below is the sample how 2 EXM800
modules (SN:3221226046, SN:3221226047) was registered on the system
Service Mode: System Setup: Modules:
System Setup Modules Set Addresses
SN:3221226046 SN:3221226046 Registering...
Address: Address: 5
SN:3221226047 SN:3221226047 Registering...
Address: Address: 6
If the correct serial number and address is entered the module will start to flash it's address with the green LED. If a
mistake was made while entering the serial number the module will stay unregistered. If a mistake was made while entering
the address which is used by another module, then the new module will overtake this address and the other module will stay
unregistered.
When all modules are registered successfully it is recommended to give reasonable names for modules. For example:
Garage Expander, 2nd floor Keypad. The system will use these names later when sending a problem or status reports in
SMS messages.

THE TEMPLATE Keypad


In order to simplify instalation the manufacturer supplied Z1 - Entry Door WC Kitchen box
SecoLink keypads with a copy of “2 rooms apartment” template
(see Fig. 4). It has a preprogrammed partition and 8 zones. +BELL - Siren
PARTITIONS: Hallway Z3 - Kitchen
CP

1st (only) system partition : Z5 - Smoke detector


status: Enabled; Z2 - Hallway
Z6 - CP tamper
pre-set name: “Apartment”;
exit delay: 30 sec.*; (could be different for each PAS832 partition);
entry delay: On**; (could be different for each PAS832 partition); Living room
common corridor function: Off** Z4 - Bedroom
timer assigned to the partition: None.
* - changing the setting is possible with KM20B (sw.v.>=4.011a)
or MASCAD; Bedroom
** - changing the setting is possible with MASCAD only.
Fig. 4 Example of template
Page 2
System with KM20B, KM20BT keypads
Intruder alarm system Short programming manual - basic information

THE TEMPLATE (continued)


ZONES PGM OUTPUTS
1st system zone: Output +BELL:
address 00_1 (Z1 terminal on CP); address 00_1 (+BELL terminal on CP);
assigned to partition:1; pre-set name: “Siren +PWR”;
pre-set name: “Entry Door”; PGM definition: Fire / Burglary Alarm;
zone definition: Entry/Exit; alarm time: 5 minutes;
loop (detector) type: NC; attributes: (+) Pulse;
zone speed (sensitivity): 0,4 sec.; trigger: All violated zones and tampers of modules;
entry delay: 30 sec.; Comment: intended to be used as a power&trigger for non back-up
attributes: (+) Bypass Enabled, (+) Limit alarms, siren. For the back-up siren +BELL definition should be changed to
(+) Limit reports; Power Supply and alarm trigger should be provided by -PGM (1).
comment: intended to be used with a Output -PGM (1):
magnetic door contact. address 00_2 (-PGM(1) terminal on CP);
2nd system zone: pre-set name: “Siren Trigger”;
address 00_2 (Z2 terminal on CP); PGM definition: Fire / Burglary Alarm;
assigned to partition:1; alarm time: 5 minutes;
pre-set name: “Hallway”; attributes: (+) Pulse;
zone definition: Follower; Trigger: All violated zones and tampers of modules;
loop (detector) type: NC; Comment: intended to be used as a power&trigger for low power
zone speed (sensitivity): 0,4 sec.; siren (buzzer) or as a trigger for the back-up siren .
attributes: (+) Entry route, (+) Exit route, Output +PGM (2):
(+) Bypass Enabled, (+) Limit alarms, (+) Limit address 00_3 (+PGM(2) terminal on CP);
reports; pre-set name: “Smoke detect.PWR”;
Comment: intended to be used with PIR PGM definition: Fire Power Supply;
detector. reset time: 10 sec.;
3rd system zone: reset triggered: by zone 5 violation;
address 00_3 (Z3 terminal on CP); Comment: intended to be used as a power supply for smoke detectors.
assigned to partition:1;
pre-set name: “Kitchen”; REPORTING
zone definition: Interior; Reporting via PSTN:
loop (detector) type: NC; reporting: Off;
zone speed (sensitivity): 0,4 sec.; telephone line monitoring: Off;
attributes: (+) Bypass Enabled, (+) Limit alarms, dial tone test: Off;
(+) Limit reports; dial method: Tone;
Comment: intended to be used with PIR dial attempts in 1 session: 4;
detector. number of sessions: 3;
4th system zone: pause between sessions: 1 min.;
address 00_4 (Z4 terminal on CP); line missing time for PSTN line trouble detection: 1 min..
pre-set name: “Bedroom”; Reporting via Radio/GSM/GPRS transmitters:
other settings same as for the 3rd zone. Reporting: Off.
5th system zone: Time settings for Periodic Test reporting:
address 00_5 (Z5 terminal on CP); days: 0 (0 = disabled);
assigned to partition:1; time: 00:00.
pre-set name: “Smoke detector”;
zone definition: 24h smoke; MODULES
loop (detector) type: NO; Control Panel:
zone speed (sensitivity): 0,4 sec.; pre-set name: “Control Panel”;
attributes: (+) Fire Verification, Limit alarms, assigned to partition: 1;
(+) Limit reports,(+) Bypass Enabled; module tamper (terminal Z6): On;
Comment: intended to be used with smoke entry delay for Entry/Exit zone: On**;
detector. Attribute indicates that detector modules monitoring: On**;
power supply must be +PGM(2). arming during the exit delay regardless of zone violation : Off**;
6th system zone: detection of not wired PGM (PGM uses no power): Off**;
address 00_6 (tamper switch on CP); +BELL auto shutdown when back-up battery is discharged: On**;
If the tamper function is needless it -PGM(1) auto shutdown when back-up battery is discharged: On**;
can be turned OFF, and zone: +PGM(2) auto shutdown when back-up battery is discharged: On**.
address 00_6 (Z6 terminal on CP); Keypad
will serve as usual zone. pre-set name: “LCD Keypad”;
7th system zone: assigned to partition: 1;
address 01_1 (Z1 terminal on keypad); module tamper: Off;
other settings same as for the 1st zone. emergency keys:
Fire alarm: On*;
8th system zone: Medical alarm: On*;
address 01_2 (Z2 terminal on keypad); Panic alarm (audible): On*.
other settings same as for the 2nd zone.
Page 3
System with KM20B, KM20BT keypads
Intruder alarm system Short programming manual - basic information

THE TEMPLATE (continued)


USERS GLOBAL TIME SETTINGS
user name: Service ; alarm time on keypad : 10 sec.;
status: Active (enabled); exit delay: 30 sec.;
default PIN: 0000. auto arm delay: 30 sec.;
user name: 1st user; pre-alarm time: 10 sec.;
status: Active (enabled); Arm/Disarm notification time for PGM output: 0,5 sec.**;
default PIN: 0001; smoke detector settle time: 5 sec.;
user rights: all rights are turned On; fire zone verification time:15 sec.;
Reporting delay on Entry zone alarm: 30 sec.*;
users: 2-3, 4-15, 16-31; AC missing time for AC loss detection: 3 min.;
status: Inactive (disabled); reporting and alarm shutdown when zone is triggered more than: 7 times**;
default PIN: 0002-0031; reset alarms counter for each zone: every 9h**.
user rights: all rights are turned On;

SECOLINK SYSTEM ELEMENTS TO BE PROGRAMMED


(Follow the steps)
PARTITIONS (1st step) USER INTERFACE (7th step)
Number of partitions [1-4] Keypad settings:
Partition name [up to 16 symbols] User interface [4 types]
Exit delay for each partition: [1-255 sec.,for PAS832 only]* Simple 1 part., Advanced, Baltic, Asian
Entry delay [On/Off]** Date format
Arming by timer in STAY mode [1-4-8-16 timers] DD/MM/YYYY or YYYY-MM-DD
Pre-alarm by timer [1-16 timers, for PAS832 only]** F-keys [up to 32 F-keys]**
Common partition (corridor) [On/Off]**
Chime
MODULES (2nd step) Other settings:
PIN length, LCD backlight, contrast, ...
Module name [up to 16 symbols]
Module address [1-7 or 1-15] RCM800(wl) settings:
Belongs to partition [1-4] Commands: [up to 38 commands]**
Use module tamper [Yes/No] MACROS: [up to 8 MACROS]**
Module specific settings:
Emergency keys for the keypad, settings for the proximity card reader PROX8, ...*
PROX8 settings:
Priority sequence for arming modes:
ZONES (3rd step) PGM OUTPUTS (4th step)
Away/Max Away/Night/Stay ...*
Zone name [up to 16 symbols] PGM name [up to 16 symbols] Installation: [Indoor/Outdoor]*
Zone address [MA_Z] PGM address [MA_P] Hide system status: [Yes/No]*
MA is module address, Z is zone
MA is module address, P is PGM Intruder RFID:*
terminal on module PCB
terminal on module PCB
Zone loop type [7 types] No action/Indication/Alarm Intruder RFID...*
NO, NC, NC/EOL, NC/DEOL, ... PGM definition [20 definitions]
Fire/Burglary Alarm, Burglary Alarm,
Managed partitions: [1-4]*
Zone definition [21 definitions] Tamper Alarm, ...
Entry/Exit, Interior, Perimeter, ...
PGM attributes [5 attributes] USERS (8th step)
Zone speed [0,4-2,5 sec.] Pulse on fire, Pre-alarm, Latch, ...
Zone attributes [9 attributes] User activation:
Triggering Source 1
Bypass enabled, No alarm zone (for [Temporary PIN for new user On]
temperature zone only), ... Zones, partitions, timers, trouble
types**, alarm types** User name [up to 16 symbols]
Entry delay [1-255 sec.]
For Entry/Exit only Triggering Source 2 User rights [13 rights]
Modules, partitions, trouble types** Arm, Disarm, Clear alarm, ...
Controlled partitions [1 to 4]
REPORTING SETTINGS (5th step)
TIMERS (optional step)
Reporting via PSTN Reporting via GSM/GPRS, RF
Phone numbers, client account, Client account Timer name [up to 16 symbols]
number of attempts in dialing session,
dialing method (tone/pulse), PSTN line
Timer On time
monitoring, ... Timer Off time
Scheduler
GLOBAL TIME SETTINGS (6th step)
Alarm time on keypad: [1-255 sec.] SECURITY SETTINGS (optional step)
Exit delay for all partitions (except PAS832): [1-255 sec.]
User PIN resetting to default: [Enabled/
Smoke detector settle time: [0-255 sec.]
Disabled]
Fire zone verification time: [0-255 sec.]
Duress code: [Enabled/Disabled]
Immediate reporting on Entry zone alarm: [Yes/No]*
Other global time settings...

Page 4
System with KM20B, KM20BT keypads
Intruder alarm system Short programming manual - basic information

SYSTEM PROGRAMMING BY KEYPAD


PARTITIONS (1st step) MODULES (2nd step) M01 Extend.Sett Preferred arming mode will
KM20B appear as first option. With
Service Mode: Service Mode: preferred arming mode
System Setup System Setup Users of system with correctly set user will spend
“corridor” type partition may less time on arming. Arming
System Setup: System Setup: prefer to exclude emergency
Partitions Modules mode are indicated by PROX8
keys in corridor keypads. This LED color:
P01 Name Modules: setting is available in KM20B
Apartment Settings with firmware >= 4.011. Red color - Away
Blue color - Night
It is recommended to give a M00 Name Fire Alarm Green color - Stay
reasonable name to a Control Panel Yes White color - Max Away
partition. The system will later Yes = emergency key is
use it to send SMS or to show It is recommended to give a Second mode
reasonable name to module. available on keypad. Max Away
t h e pa r t i t i o n s ta t u s o n No = emergency key is not
keypad's LCD. The module name will appear Away, Max Away, Stay, Night
on keypad LCD if there will be available on keypad.
To type in partition name find modes can be set as second
out a suitable character by a trouble with the module. Medical Alarm option.
pressing corresponding key. Note: module address is Yes
For next character possition shown on the upper-left corner Third mode
Yes Stay
press or key. To delete of LCD (eg. M00 = 00 No
character move a cursor on Away, Max Away, Stay, Night
wrong character and press M00 Type Panic Alarm
PAS808 modes can be set as third
0 . Yes option.
P01 In Use Available module types: Yes Fourth mode
Yes PA S 8 0 8 , PA S 8 0 8 M , No Night
PAS808R, PAS816, PAS832,
For operation flexibility the KM20B, KM20BT, KM24, Panic Silent Away, Max Away, Stay, Night
alarm system can be divided KM24A,RCM800, RCM800wl, Yes modes can be set as fourth
to 4 partitions. Confirm the EXT116, EXT216, GSV2A, Yes = panic silent. option.
activation of new partition by GSV2C,GSV2M EXM800, No = panic audible.
selecting “YES” . Press # ! Note: if there are need of
RID820, PROX8, PWR15, only 1 arming mode, program
key for the next partition . If LAN800. Partition
only 1 partition is used, skip +Partition 01 all options with the same
this menu entry. M00 Serial No. mode.
536870987 By default keypad is related
Yes = partition is used. with all partitions. Partitions
No = partition is not used. SecoLink modules are If the partitioned system is -Partition 01
manufactured with unique separately used by individuals This setting allows PROX8
P01 Exit Delay serial numbers. See page 2 for
30 seconds or companies and keypads are to control only assigned
more information about SN. placed inside of partition partitions. The assigned
The Exit Delay time is same M00 Use Tamper premises it’s recommended to partition troubles and NOT
for all partitions in PAS808, Yes relate keypad with it’s partition. READY status will be visible
PA S 8 0 8 M , PA S 8 0 8 R , This way user of one partition on PROX8 status LED:
PAS816 panels, but can be set For more security it’s recom- will be not disturbed by alarms, Red color - Alarm
different for each partition in mended to use tamper to entry/exit delay sounds of Red blinking - Alarm memory
PAS832 panel. protect modules. Tamper can other partitions. Green color - Not Ready
The Exit Delay time is be activated by using: “+” = partition will be controlled Yellow color - Trouble
programmable within 1 - 255 and monitored by keypad; Blue color - Bypassed Zone
Z6 - on control panels;
seconds range . “-” = partition will not be
Z1 - on EXM800; Press # key to assign
!

controlled and monitored by


P01 Timers TMP - on RCM800(wl); partition to the module.
keypad;
-Timer 01 back switch - on keypads. “+” = partition is assigned.
If Use Tamper selected as EXTENDED SETTINGS “-” = partition is not assigned.
By assigning a timer to a
partition it's possible to make “NO” for a module, then Z6 FOR PROX8 Sound
the partition's auto-arm and Z1 can be used as zone Yes
schedule. Partition can be terminal for control panel and M06 Extend.Sett
EXM800. PROX8 Yes = audible notification for
armed by a timer only in the
arm, disarm, failure is On.
Stay mode. Auto-arming will M00 Extend.Sett Installation No = audible notification is
be aborted if there are any PAS808 Indoor Off.
open perimeter zones or
system troubles. Most new system settings If PROX8 is set as an indoor HideStatusIndi
are added to menu as module it’s starts Entry/Exit Yes
Press # key to assign timer
!

extended module’s settings. delays for most arming


to partition. Check a keypad firmware modes. Yes = the system status will
“+” = timer is assigned. version and a list of extended If PROX8 is set as an outdoor be shown for 5 sec after last
“-” = timer is not assigned. settings compatible with it . module the Entry/Exit delay is action.
Note: more settings can be excluded. No = the system status will
made by using MASCAD EXTENDED SETTINGS be shown always.
software. For more details FOR KM20B, KM20BT Preferred mode
read “Advanced Programming Away Intruder RFID
manual”. No action
Page 5
System with KM20B, KM20BT keypads
Intruder alarm system Short programming manual - basic information

SYSTEM PROGRAMMING BY KEYPAD (continued)


Module has 3 options what it In order to program double Panic Audible Interior Night Armed
must do when the non- zones, the corresponding Same as Panic Silent, just an This zone is the same as
assigned (intruder) RFID tag letter (A - for sensor A or B - for alarm will be audible. Interior zone, but unlike the
is detected close to the sensor B) must be entered Burglary/Tamper alarm zone: Interior zone, this zone will be
module: next to 3-digit number MA_Z. 24h Tamper armed in Night mode (for
No action Use A or B key to enter the
!
BYP
An opening of 24h Tamper PAS832 and keypad KM20Bx
Indication - module starts to necessary letters (example: zone will trigger a tamper firmware v4.125 or higher).
blink with red LEDs and starts 00_1 A, 00_1 B, ...). alarm regardless a system is Entry/Exit Forced
to sound the annoying noise. Z01 Loop type armed or disarmed. This zone is the same as
Alarm Intruder RFID - NC Fire alarm zones: Entry/Exit zone, but unlike the
module starts to blink with red 24h Fire Entry/Exit zone, this zone
LEDs and starts to sound the Depend on security 24h Smoke definition allows to arm the
annoying noise. The alarm will requirements different type of An opening of Fire zone will system when the entry/exit
be triggered after three loops are used for detectors trigger a fire alarm regardless zone is violated (for keypad
attempts to control system wiring. See wiring diagram for a system is armed or KM20Bx firmware v4.125 or
with non-assigned tag is each type. disarmed. Control panel will higher).
detected. Not used send a fire report to CMS,
NC Z01 Zone Speed
alarm is audible. 0,4 seconds
Operation Mode NO To avoid false alarms, a zone
Small System NC/EOL attribute “Fire Verification” is By selecting zone speed it’s
The PROX8 is designed to NO/EOL recommended to use. possible to adjust system to a
have different meanings of NC/DEOL Fire button various type of detectors.
active LEDs when system is in NO/DEOL Fire button definition is used Normally zone speed is within
different operation mode. VIBRO (PAS808M, PAS832 only) for zones which is wired with 0,1 - 2,5 seconds range.
The meaning of LEDs in NC S&W (PAS832 only) button for fire alarm activation. With “VIBRO” zone loop type
Small System mode: Z01 Partition Medic alarm zone: selected, the zone speed must
1st and 2nd LED are 1 Medic button be within 0,01 - 0,25 seconds
showing the arming mode of Medic button definition is range (fast zone). Fast zone
1st and 2nd partition; By default all zones are used for zones which is wired is available for PAS832,
3rd LED is showing assigned to 1st partition. with button to make a call for a PAS808M only.
troubles in the system; Z01 Definition medical assistance. Z01 Attributes
4th LED is showing alarm, Entry/Exit Technical alarm zones: +Limit alarms
alarm memory, not ready 24h Fire supervisory
Zone definition allows to Zone attribute is an extra
status and zone bypass. Low Water Level
group zones for arming specification used to
If the system has 3 partitions 24h RF Jam
modes, to specify how zone determine zone’s operation
then arming mode of the 3rd Gas Detected
operates during an arming or during system arming or alarm.
partition will be shown on 3rd Water leakage
when system is armed. Limit alarms
LED, the troubles in system High Temperature
Burglary alarm zones: To avoid numerous false
will be shown on 4th LED. Low Temperature
Entry/Exit alarms, by default, a system
In Large System mode (4 This group of definitions is
Zone with Entry / Exit is set to make zone shutdown
partitions) the same LED is used for a 24h technical zones
definition will start Entry Delay when 3 or 7 (PAS832)**
showing all information of the to report about abnormalities
when system is armed in Away violations of zone are detected.
assigned partition, i.e. 1st LED in environment.
or Stay mode. Limit reports
is showing 1st partition’s PGM control
Interior The shutdown will be active
arming mode, alarms, Zone with PGM control
Zone with Interior definition for reporting.
troubles and zone bypass. definition mostly used to
will be ignored in Night or Stay Note: when this attribute is set
activate PGM outputs when
mode. to (-) the keypad automatically
ZONES (3rd step) zone is triggered. Zone will be
Perimeter changes Limit alarms attribute
triggered regardless system is
Service Mode: Violation of zone with to (-).
armed or disarmed and no
System Setup Perimeter definition will make Fire Verification
alarm will be activated.
instant alarm when system is Used with 24h fire zones.
For PAS832 panel PGM
System Setup: armed in Away, Stay, Night or With this attribute being set the
control definition may be used
Zones Max Away mode. triggered fire zone, first of all,
to make a KEY-SWITCH zone.
Instant Violation of zone will wait for fire detector power
Z01 Name With the help of MASCAD it’s
with Instant definition will make supply reset and later will
Entry doors possible to set KEY-SWITCH
instant alarm when System is check violation again. It’s
zone for system armin g,
Zone name will be used by armed in Away, Stay, Night or recommended to use
disarming or clearing an alarm.
system for SMS sending or Max Away mode. +PGM(2) as fire detector
Follower
to show on keypad LCD an 24h Burglary power supply.
This zone is the same as
open/bypassed status. An opening of 24h Burglary In Exit Route
Interior with In Exit Route and
zone will trigger an alarm With this attribute being set
Z01 Address In Entry Route attributes
regardless a system is armed zone with Interior definition can
00_1 automatically being set.
or disarmed. be violated during Exit Delay.
Follower Night Armed
Zone address is a 3-digit Panic Silent In Entry Route
This zone is the same as
number MA_Z (“00_1”) where An opening of Panic Silent With this attribute being set
Follower zone, but unlike the
MA (“00”) specifies a module zone will trigger an alarm zone with Interior definition can
Follower zone, this zone will be
address on system (see page regardless a system is armed be violated during Entry Delay.
armed in Night mode (for
1) and Z (“1”) specifies a zone or disarmed. Control panel will
PAS832 and keypad KM20Bx
terminal on module PCB. send a panic report to CMS.
firmware v4.125 or higher).
Alarm will be silent.
Page 6
System with KM20B, KM20BT keypads
Intruder alarm system Short programming manual - basic information

SYSTEM PROGRAMMING BY KEYPAD (continued)


Arm On Exit O01 Definition Exit /Entry Delay Warning O01 Attributes
This attribute used only for Burglary Alarm PGM output activates if an -ArmFailNotif
Entry/Exit zone. With this entry/exit delay is running in
By setting PGM definition PGM attributes are specific
attribute being set system the selected partition.
installer will describe what options that help determine
stops Exit Delay time and arm Exit Delay/Arm Status
kind of alarm system activity how each definition functions,
immediately when exit door is PGM output activates in an
will be related with the PGM. and they must be manually set
closed. exit delay is running or the
Not used as soon as the PGM is
Without Alarm selected partition is being
Unused PGM output should defined.
Zone violation does not armed.
be programmed as Not Used. Arming Failure Notification
make an alarm, but can start Full Arm Status
Fire Alarm PGM output activates if a
PGM action (for zone with PGM output activates if a fire
PGM output activates if all of
definition 24h High the selected partitions are failure to arm is present due
alarm occurs on the selected trouble or zone violation (5
temperature or 24h Low fire zone or when module fire armed.
temperature only). Notifications** pulses).
emergency keys are pressed. Pre-alarm
Bypass Enabled Fire/Burglary Alarm PGM output activates if the
Allows to bypass zone. selected partition being armed PGM output activates if a
PGM output activates if a Pre-alarm alarm occurs.
Press # key to set attribute.
!
fire/burglary alarm occurs on (1 pulse), being disarmed (2
pulses). Latch
“+” = attribute is set. the selected fire/burglary zone PGM output will latch until a
“-” = attribute is not set. or when module fire, panic In case of unsuccessful
arming the PGM output valid user code is entered or is
Z01 Entry Delay emergency keys are pressed. cleared from menu (depends
Note: PGM output activates activates for 5 pulses.
20 seconds After alarm clearing this type on definition ).
when system is armed and the Pulse
Used for Entry/Exit zone only selected zone or the module PGM output can be switched
On (Off) for an appropriate To help the user separate
to allow user to enter PIN for tamper condition are present.
time. burglary alarm (steady) from
system disarming. Entry Burglary Alarm
Power Supply fire alarm (pulsating) this
Delay time is programmable PGM output activates if a
PGM output can be used as attribute must be assigned to
within 1 - 255 seconds range. burglary alarm occurs on the
a power supply for an external the PGM output (PGM output
The violation of zone with selected burglary zone or
devices. generates 1Hz pulses).
Follower definition or zone when module panic emer-
Resettable Power Supply Inversion of Status
with Interior definition and In gency keys are pressed.
PGM output can be used as This attribute is used to invert
Entry Route attribute will not Note: PGM output activates
a power supply for an external the normal state of the output.
trigger alarm during Entry when system is armed and the
delay. selected zone or the module devices. O01 PulseLength
tamper condition are present. It can be switched Off for 5 minutes
Z01 Pre-alarm appropriate time period from
Yes Tamper Alarm Pulse length determines how
PGM output activates if a the keypad.
long PGM will be switched
When Pre-alarm zone is tamper alarm occurs on the Fire Power Supply
On/Off. The range within 1
violated, system will make an selected zone or module. PGM output can be used as
sec. and 255 min.
alarm without reporting to Technical Alarm power supply for fire or smoke
CMS or to user. PGM output activates if a detectors. O01 TrigSource1
Yes = zone will trigger technical alarm occurs on the When the system requires a +Zones 01
Pre-alarm. selected zone or module. reset for these detectors the O01 TrigSource2
No = zone will not trigger. Selected Alarms** output will be switched Off for +Modules 01
PGM output activates if the an appropriate time.
PGM OUTPUTS (4th step) selected type alarm occurs on This output will be switched From which system element
the selected partition. A l a r m Off each time after system (zones, partitions, timers,
Service Mode: types: fire, burglary, tamper, arming, alarm clearing. This modules, alarms and trouble
System Setup silent panic, audible panic, output can be switched Off types) PGM will be triggered
technical and medical alarms. from menu also. depends on PGM triggering
System Setup: Only one this type PGM sources 1, 2.
Chime
PGM Outputs output is available for control After adding new elements in
PGM output activates if the
O01 Name selected zone is violated panels PAS808, PAS808M to the system, these elements
Siren +PWR (when system is disarmed). and PAS816. should be assigned to
Zone Violation Timer corresponding PGM sources.
It is recommended to give a PGM output activates if the PGM output activates when
reasonable name to the PGM. REPORTING SETTINGS
selected zone is violated. a selected timer activates and
(5th step)
O01 Address Additional feature for this deactivates when selected
00_1 PGM definition: if pulse length timer deactivates. Service Mode:
is 0 seconds then PGM will be Mono/Bi Switch Report Setting
PGM address is a 3-digit switched On (Off) until any of Output activates for preset
number MA_P (“00_1”) where The following section
the selected zones were time duration from a zone
MA (“00”) specifies a module explains all options that must
violated. violation or from the keypad. If
address and P (“1”) specifies a be programmed in order to
Bypass Status the time is preset to the
PGM terminal on module PGM output activates when properly report system
0 seconds, the output is active eventsto a Central Monitoring
PCB. To program PGM it’s zone is bypassed, and until the next signal from the
necessary to enter the correct deactivates when the zone is Station(CMS).
zone or from the keypad Contact ID reporting protocol
PGM address. reinstated. appears.
System Trouble** is used by default. Additional
PGM output activates if any reporting protocol Ademco
selected trouble is present. 4x2 slow is available for
control panel PAS832 only.
Page 7
System with KM20B, KM20BT keypads
Intruder alarm system Short programming manual - basic information

SYSTEM PROGRAMMING BY KEYPAD (continued)


REPORTING VIA PSTN PauseBTWsessio TIME SETTINGS ACLossRepDelay
1 minutes Service Mode: 3 minutes
Report Communica
PSTN Communica This parameter determines Report Setting If the AC power is lost for
the amount of time the control longer period of time then is
Reporting panel will wait before
Report Communica set in this parameter, the
Disabled proceeding the next session.
Time Settings report will be sent to CMS, the
This menu allows to enable/ [1-30 min.] This menu entry is used to keypad will display the trouble
disable reporting to CMS via configure periodic test on screen.
Dial Tone Test schedule.
PSTN line. No [1-30 min.]
1-15 sessions. Per.ReportTime SensSettleTime
Enabled If parameter is set to “Yes”, 00:00
the system waits for the 5 seconds
Disabled
telephone line tone before Use the 24-hour clock to The sensor settle time is
Tel. Number X dialing. program the time. selected to be the time
9p85478514254 Yes Pause in Days expected for the fire detector
The control panel can dial up No 1 to become substantially
to 2 (4) different telephone Method settled after power up.
The control panel will transmit
numbers. Tone he test report code after the [1-255 sec.]
Additional symbols: p - 3 sec. number of days programmed
Tone FZoneVerifTime
pause, P - 10 sec. pause, w - into this parameter.
Pulse 5 seconds
wait dial tone can be entered 0 = periodic test is disabled.
by pressing key # . LineMonitoring If the fire zone is violated, the
Note: control panel will call No GLOBAL TIME SETTINGS system performs a fire alarm
to user when additional (6th step) verification procedure to
If parameter is set to “Yes”
symbol “p” is entered before confirm the actuality of the
then Control panel constantly
phone number (for PAS832 Service Mode: alarm. How long the system
checks the presence of the
and PAS808M only).User System Setup waits for second fire zone
telephone line voltage.
must acknowledge the call by verification procedure to
pressing [ ] key on the phone, Yes System Setup:
No Time Settings confirm the actuality of the
otherwise control panel will alarm. How long the system
call again. LineLossDelay Exit Delay waits for second fire zone
1 minutes 30 seconds violation is described in this
Account Number The control panel indicates The Exit Delay time is same parameter.
B001 telephone line tampering if the for all partitions in PAS808, [1-255 sec.]
telephone line voltage is PAS808M, PAS816 panels,
A 4 - digit account number absent for longer time than is Immid.EntryAla
CMS uses to identify the but can be set different for No
set in this parameter. each partition in PAS832
client. [1-30 min.] If parameter is set to “Yes”
Additional symbols: B, C, D, panel (see 1st step).
REPORTING VIA The Exit Delay time is then control panel will sent the
E, F can be entered by report about Entry/Exit zone
pressing key # .! RADIO/GSM/GPRS programmable within 1 - 255
TRANSMITTERS seconds range. violation i m m e d i a t e l y,
DialsInSession KM20 AlarmTime otherwise report will be
4 Service Mode: 10 seconds delayed for 30 seconds.
Report Setting Yes
The value programmed in It is the time, when keypad will
this parameter determines sound an alarm and display No
Report Communica
how many times the control SERIAL Connect the name of violated zone.
panel will re-dial to all USER INTERFACE
[1-255 sec.].
monitoring station numbers Reporting (7th step)
before proceeding to the next Disabled AutoArm Delay
10 seconds Main Menu:
session. This menu allows to Options
1-15 dials in one session. enable/disable reporting to Arming by the timer can be
Sessions CMS or to user via Radio, delayed. The delay time is Options:
1 GSM, GPRS channels. programmable within a 1 - 255 Keypad Setting
Enabled seconds range.
Maximum possible amount Keypad Settings:
Disabled Pre-alarm Time PIN:****
of unsuccessful dials (to all
telephone numbers) is Account Number 10 seconds
calculated by multiplying C002 Light
After pre-alarm zone is LCD
number of sessions and violated the keypad will sound
A 4 - digit account number
number of dials in session. an alarm and will display zone LCD and keypad key
CMS uses to identify the
In case of unsuccessful name. If the PGM has attribute backlight can be adjusted to
client.
dialing during one session the “Pre-alarm” set, then it will be suit user needs.
Additional symbols: B, C, D,
system waits for a specified switched On (Off). Pre-alarm LCD
E, F can be entered by
time (see “Pause Between time is programmable within a LCD backlight is always On;
pressing key # .
!

Sessions”). 1 - 255 seconds range. LCD&keypad


After this time the system will LCD and keypad key
try to repeat dialing procedure. backlight are always On;
1-15 sessions.
Page 8
System with KM20B, KM20BT keypads
Intruder alarm system Short programming manual - basic information

SYSTEM PROGRAMMING BY KEYPAD (continued)


Auto Hide troubles SECURITY SETTINGS PROJECT LOADING
LCD and keypad key No (optional step) FROM KM20 TO CP
backlight goes Off if no keys
are pressed in 15 seconds. When trouble is active and Service Mode: Project Loading:
key CLR is pressed twice the System Setup From KM20 to C
LCD Backlight “Trouble” LED starts to blink
fast (hiding the trouble). Service Mode: From KM20 to CP
The illumination level of the If parameter is set to “Yes”, SecuritySettin Processing...
LCD can be modified to suit then the troubles will be
PIN Resetting Status “Processing...” means
user needs. hidden until the trouble
Disabled that system is busy. Wait until
disappears, otherwise trouble
Contrast the system will finish this
will be hidden for 30 seconds This setting allows to enable
procedure.
Yes or to disable access to special
The contrast level of the LCD It is recommended to make
No user menu, where installer
can be modified to suit user this procedure each time after
with his PIN can reset 1st user
needs. Date format modules registration.
PINs to default. If this option is
DD/MM/YYYY enabled 1st user has right to RESTORE PROJECT
Sound
Loud DD/MM/YYYY reset all enabled user PINs to Project Loading:
YYYY-MM-DD default too. Restore Projec
The sound level of the Enabled
k e y pa d b u z z e r c a n b e PIN length Disabled Restore Project:
modified to suit user need. It Fixed 4 digits Main settings
changes the chime and When PIN length is fixed,
Duress
keypad key press sound level. then isn’t necessary to press
Disabled Restore Project?
The level of Entry/Exit delay, ENT
after entering the PIN. This setting allows to enable
ENT=Yes, CLR=No
alarm sound remain the same. or to disable duress code This menu entry allows to
Fixed 4 digits
Loud Fixed 5 digits (Duress code = X1, X2, X3, X4 restore the part of system
Silent Fixed 7 digits when X4 = X4 + 1). settings to default. All names,
Interface Type Variable Enabled reporting settings, user
Simple Disabled settings remains not changed.
TIMERS (optional step) Yes
An interface type mainly is PROJECT LOADING No
associated with view of the Main Menu:
main screen. Options Service Mode: Project Loading:
More details about each Project Loadin Restore Projec
interface type can be found in Options:
Timers This menu entry is used Restore Project:
the short user manuals. Full project
fordata transfer inside the
Simple - for 1 partition only Timers: system (from CP to KM20 and
Asian PIN:**** vice versa) or from/to PC.
Restore Project?
Baltic ENT=Yes, CLR=No
Advanced T01 Name PROJECT LOADING This menu entry allows to
Show Date&Time Timer 01 TO/FROM PC restore all system settings to
No Asian It is recommended to give a Project Loading: default.
reasonable name to timer. Open USB Port Yes
This parameter enables No
hiding date and time on the T01 TMR
NameOn Time Open USB Port:
main screen, instead of it the Timer Disabled
00:00 01 Ready...
brand name of product is
displayed. T01 TMR
NameOffTime Status “Ready...” means
Timer Disabled
00:00 01 that system is ready for data
Yes
upload or download.
No To program the timer On/Off
Status “Processing...” means
Prompt ChgTime time use the 24-hour clock.
that system is busy. Wait until
Yes Asian Timer will be in use when it will
“Ready...” shows up.
be enabled.
This parameter enables Enabled PROJECT LOADING
hiding the prompt “Date and Disabled FROM CP TO KM20
Time To correct press [ENT]”
after systems power up (for T01 Schedule
Name Project Loading:
Asian interface only). Timer 01
------- From CP to KM2
Yes = show the prompt. Scroll to the day of the week
No = do not show prompt.
From CP to KM20
you want to assign. Press # !
Processing...
Use trbl. memo key to assign day to timer.
Monday Status “Processing...” means
No that system is busy. Wait until
Tuesday
This parameter enables the system will finish this
Wednesday
showing the trouble memory procedure.
Thursday
with slowly flashing “Trouble” Note: Control panel PAS-
Friday
LED. 808 does not send names of
Saturday
Yes = show trouble memory. pa r t i t i o n s , z o n e s , P G M
Sunday
No = do not show trouble outputs, users and timers.
memory.